Sei sulla pagina 1di 168

Flexi Multiradio BTS WCDMA

Modules Overview
RA4531-08 RU40

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Nokia Solutions and Networks Academy


Legal notice
Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Solutions and Networks training
documentation, product documentation and slide presentation material, all of which are forthwith
known as Nokia Solutions and Networks training material, are the exclusive property of Nokia
Solutions and Networks. Nokia Solutions and Networks owns the rights to copying, modification,
translation, adaptation or derivatives including any improvements or developments. Nokia
Solutions and Networks has the sole right to copy, distribute, amend, modify, develop, license,
sublicense, sell, transfer and assign the Nokia Solutions and Networks training material.
Individuals can use the Nokia Solutions and Networks training material for their own personal
self-development only, those same individuals cannot subsequently pass on that same
Intellectual Property to others without the prior written agreement of Nokia Solutions and
Networks. The Nokia Solutions and Networks training material cannot be used outside of an
agreed Nokia Solutions and Networks training session for development of groups without the
prior written agreement of Nokia Solutions and Networks.

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Contents
After completing this module, the participant will be able to:
Theory:
List the New Units of the NSN Flexi WCDMA BTS RU40 level
List the units of the NSN Flexi WCDMA BTS
Describe the main function of each unit in the NSN Flexi WCDMA BTS
Describe the installation and configuration options for the Flexi WCDMA
BTS
List optional units of Flexi WCDMA BTS

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

NSN Flexi WCDMA BTS structure overview


Flexi BTS introduces a new platform
The modular design does not use any backplanes
All Modules are interconnected via front panel cabling
Modules can be installed in separate locations (Feederless / Distributed
Sites)
A Flexi WCDMA BTS consists of one System Module and
one optional Extension System Module (BaseBand Extension)
There can be maximum of four Radio Modules or Remote Radio Heads
Radio Modules are available with 1, 2, or 3 Power Amplifiers (PAs) each
Remote Radio Heads are optimized for 1 sector with
BTS configurations
1 cell to 24 cells with or without MIMO
Module weight: 19-25 kg per Module
The Base Station can be installed by one person
There can be up to four Radio Modules or RRH. Site installation
with RF Chaining can handle up to 12 RRHs or RFMS
connected to a single System Module.
5

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi WCDMA BTS Rel.2 HW


Flexi BTS multimode system
module is also prepared for LTE
evolution with a SW upgrade.
High capacity system module
FSMC with 240 CEs
FSMD with 576 CEs
FSME with 912 CEs
Can be used as capacity extension
for Rel.1 HW (FSMB)

CT10772EN03GLA0

Transmission sub module FTIB to support All-IP


transport and Timing over Packet (TOPA)
Transmission sub module FTLB to support I-HSPA
FRGQ,FHDA,2TX RRH, support configuration:
- 4@20W / 3@20W
- 2@40W / 1@40W
- MIMO with Single RRH up to 4 MIMO layers
with 30W
FRGP, FXDA,FRIE,FXCA,FXFA,FXEA triple RF
Modules, support configuration:
4+4+4@ 15W / 3+3+3 @ 20W
2+2+2@ 30W / 1+1+1@ 60W.
MIMO with 2 Triple RFMs up to 4 MIMO layers
with 30W
RX diversity sharing across modules

2014 Nokia Solutions and Networks. All rights reserved.

Flexi WCDMA BTS Rel.2 HW, cont.


There are the following Flexi System Modules types available:
FSMB System Module (Rel.1 HW)
FSMC Flexi Multimode BTS System Module (Rel.2 HW)

FSMD Flexi Multimode BTS System Module (Rel.2 HW)


FSME Flexi Multimode BTS System Module (Rel.2 HW)
FSMF Flexi Multiradio BTS 10 System Module (Rel.3 HW)
FBBA (Rel.3 HW) capacity extension sub module for FSMF System Module.

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Transmission and Transport Solution


Standalone AXC (S-AXC) is ATM
transmission node.
Standalone
One subrack (on the figure)
AXC
supports 2 x 1.2 Gbps of switching
capacity.
Short to long hop length
Various interface unit are available
Various frequency band: 6, 7, 8,
13, 15, 18, 23, 26, 28, 32, 38 and
58 GHz
PDH radio
SDH radio
Various indoor unit type: FIU19,
FPFM200i
IFUE or FXC-RRI
Flexbus interface
FTIF

CT10772EN03GLA0

FTFB

2014 Nokia Solutions and Networks. All rights reserved.

Transmission and Transport Solution, cont.


The FPFM200i supports the following interfaces: five electrical Ethernet Ports
10/100/1000Base-TX full duplex
10/100/1000Base-TX auto-negotiation
MDIX (10/100Base-TX)
5 x RJ45 connector (EIF1 ~ EIF5)
2 x P+E ports (EIF4 / EIF5)
four PDH ports on two RJ48C connectors - one RJ48C supports two E1/T1 ports (IF1/3 & IF2/4) one LMP port on RJ45
connector, 10/100/1000Base-T
Flexi Multiradio 10 System Module with FTIF supports Ethernet Switching across up to three interfaces and 8x E1/T1/JT1
(twisted pair); coaxial connectivity can be provided via baluns.
The sub-module is required:
for ATM Iub, Dual Iub, and IP Iub over ML-PPP
for Dynamic Abis over TDM, Dynamic Abis over IP/Ethernet (TDM pseudowire), and Packet Abis over TDM
if collocation (CESoPSN) or synchronization includesTDM
if more/other Ethernet interfaces are required than available on Flexi Multiradio 10 System Module
if Synchronization Hub function based on Synchronous Ethernet input or output is to be use.
FTFB transmission sub-module for NSN Flexi WCDMA (later referred to as FTFB) provides radio transmission interface
functionality, power supply, and control to microwave radios.
FTFB is an evolutional product of FTFA, it allows the operator to connect NSN Flexi WCDMA BTS to a Flexi Hopper (Plus)
microwave radio unit with a Flexbus interface using a single Flexbus cable with the capability to carry both Ethernet and
traditional E1 traffic, and also provides a high capacity evolution path towards Ethernet with FlexiPacket Radio, or any other GE
interface equipped unit.

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio System Modules - FSMF

10

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio System Modules FSMF, cont.


This feature provides the following operator benefits:

Secure BTS investment with flexible migration from one radio access technology
to another: GSM/EDGE, WCDMA, HSPA and HSPA evolution, and LTE TDD/FDD
radio access technologies as well as all needed frequency variants.

Support for 3GPP functions and features in 3GPP release 9 and later providing a
future proof platform for advanced radio systems.

Support for multi-operator cases (MORAN) where several operators can share
resources of one BTS.

Support for the most common interfaces between the modules and functions as
defined by Open Base Station Architecture Initiative (OBSAI) and Common Public
Radio Interface (CPRI).

Flexible capacity upgrade based on pay-as-you-grow concept.

Higher site capacities and new configurations.

Ethernet-based transport with security solutions, synchronization, and timing


methods based on Synchronous Ethernet, Timing over Packet, GPS.

Well optimized for data services.

11

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Functional blocks of the System Module (FSMF)


with FTIF, FBBA and FPFD

12

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Functional blocks of the System Module (FSMF)


with FTIF, FBBA and FPFD, cont.
Flexi Multiradio System Module is an integral part of Flexi Multiradio 10 BTS. It
supports the following software operating modes:
GSM/EDGE
WCDMA
HSPA, HSPA evolution, and I-HSPA
LTE in FDD and TDD
The tasks of the System Module are:
telecom control
system operation and maintenance
baseband processing
Transmission
Synchronization
power distribution via optional sub-module
13

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Front panel of the System Module with optional


sub-modules FPFD, FTIF,and two FBBAs

14

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Front panel of the System Module with optional


sub-modules FPFD, FTIF,and two FBBAs, cont.
Core module contains an integrated 100/1000Base-T Gigabit Ethernet transport interface towards the radio access network,
or directly towards the core network in case of LTE. The connection between the transport sub-module and the core module
is done via internal connector for both power and signal transmission.
Transport sub-module is required in the following scenarios:

TDM transport interfaces:

ATM Iub or Dual Iub.


IP Iub over ML-PPP.
Dynamic Abis over TDM.
Packet Abis over TDM.

TDM pseudowire emulation:

Dynamic Abis over IP/Ethernet (TDM pseudowire, no external PDH interfaces are needed).
CESoPSN for external traffic (external PDH interfaces are needed).

Synchronization options:

PDH as synchronization input or output.


Synchronization hub function if based on Synchronous Ethernet input or output.

Co-location and chaining:

More or other Ethernet interfaces than those available in the Multiradio System Module are required.
Optical Ethernet in case the shared RP3-01/transport port on the core module is occupied by RP3-01.

15

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Multiradio Flexi BTS WCDMA modules

16

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Multiradio Flexi BTS WCDMA modules, cont.


A BTS type called Flexi WCDMA BTS has been available since RAS05.1. Multiradio Flexi BTS WCDMA is a new, truly
modular, very compact, and high capacity wide-area WCDMA BTS that can be used in various indoor and outdoor installation
options (such as floor, wall, stand, pole, mast, cabinet, 19" rack) and site applications (mini, macro, and distributed site
solution).
This solution can also be used as a multimode upgrade to existing UltraSite EDGE BTS with WCDMA carriers.
Multiradio Flexi BTS WCDMA consists of the following self-supporting BTS modules:

Radio Module provides the Radio Frequency (RF) functionality. Maximum of three RF Modules can be directly connected
to the Master System Module.

System Module provides baseband processing as well as control and transmission functionality;

System Module capacity depends on system module type, for details see section 2.1.2. The number of Rel99 CEs
activated can be increased by license control;

The Baseband Extension Module is also available. In case of two system modules in one BTS, Flexi System Extension Kit
cable set (FSKA) is required.

There are four kinds of RF Modules available, namely:

Release1 Single RF Module (50W supporting one sector);

Release1 Dual RF Module ( 50W supporting one or two sectors);

Release2 Triple RF Module (70W supporting one, two, or three sectors);

Release2 RRH Module (70W supporting one sector);

Release3 Triple RF Module (90W / 6Gb OBSAI interface supporting one, two or three sectors);

17

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

OBSAI (Open Base Station Architecture Initiative)


interfaces
RF Module
Additional Frequencies

OBSAI Interface

System Module

PROCESSING

OBSAI Interface
TRANSMISSION

18

IP/ATM/PDH/SD
H

CONTROL

OBSAI Interface

OBSAI Interface

RADIO

The OBSAI family of specifications provides the architecture, function descriptions,


and minimum requirements for integration of a set of common modules into a base
transceiver station (BTS).
As a minimum, the BTS will have the capability to be configured from a set of
common modules in order to support one or more current or future wireless network
access standards.
The technical requirements in the OBSAI specifications form an interface specification
to ensure compatibility and interoperability among and between the set of common
modules.
The requirements do not address the quality or reliability of service of the access
standards, nor do they cover measurement procedures.
CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

OBSAI (Open Base Station Architecture Initiative)


interfaces, cont.
Flexi Multiradio System Module is fully OBSAI compatible and has all the control
and baseband functions for the supported radio access technologies.The
architecture of Flexi Multiradio System Module enables utilization of several
System Module and sub-module variants. The System Module consists of a casing
within the following baseband modules: a core module and up to two optional
capacity extension sub-modules.

19

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS Field-Proven OBSAI


Architecture

20

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

NSN Flexi WCDMA BTS Modules

5.25
17.05
133 mm
3 HU
422 mm
without covers
560 mm
with covers
22.05

447 mm

17.6

for 19 inch rack installation


Weight: 19-25 kg
42 55
Lbs

21

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

NSN Flexi WCDMA BTS Modules, cont.


All NSN Flexi WCDMA modules are outdoor-capable, hermetically sealed and IP 55 class protected.
The number of modules are minimised, e.g. for typical a 1+1+1 configuration only 2 dual PA modules are needed.
Module core

Core mechanics with optional front and back covers shield the module against water, snow, and solid foreign objects, and
makes the module IP 55 weather resistant.

Core mechanics provide EMC shielding.

All connectors are located in the front with weather-protecting covers.

Module casing

Casing supports the pile of modules.

Module Core can be changed ; even when the module is at the bottom of the module stack

Outdoor cabinet includes door lock and door alarm switch.


Fan sub-module

Fan sub-module provides the fresh air cooling to module.

The System Module controls the fans according to temperature information.

Two redundant fans enable module operation if one fails in normal temperature.

Fan sub-module can be changed in during normal operation at sites where rear access is provided.

22

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

NSN Flexi WCDMA BTS Mechanics

Core
(can be pulled out for replacement)

Casing(enables
(to enablepulling
core pull
out out)
the core)

Optional front
Front
Cablecover
cable
Cover and Fan

(can be replaced on site)


23

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

NSN Flexi WCDMA BTS power supply architecture


Optional Outdoor cabinet
Two PA RF Module

In local installations,
the System Module
provides DC power
supply to the Radio
Modules and optional
System Extension
Module.

In Feederless /
Distributed Sites, the
DC power supply to
Radio equipment
may be provided by
any other (-48V) DC
source.

Two PA RF Module

-48V DC

Two PA RF Module
Optional
Extension System
Module (RAS05.1 ED)

BTS System
Module
230V AC
or
24V DC
24

ACDC
or
DCDC

CT10772EN03GLA0

BBU

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Lite BTS

25

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Lite BTS, cont.


Flexi Lite BTS baseband unit consists of subunits that can be used for the
following:
CCCH processing;
R99 users processing;
HSDPA users, and throughput processing;
HSUPA users and throughput processing;
CS Voice over HSPA users processing;
Interference cancellation processing.
Note that Flexi Lite BTS contains baseband resources for Common Control
Channels processing for 4 cells/15 km cell range, 3 cells/20km cell range or 2
cells/30km configurations included in BTS capacity. However from practical
side (indoor/outdoor micro cell environment) lower cell ranges are expected (for
example: 100/300/500 meters).

26

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Lite BTS


Availability after C5, new HW.

27

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Lite BTS, cont.


This feature benefits operator as follows:

28

The product can be used in pico and microcellular applications and also as a
coverage fill-in solution. The main use case is in capacity limited networks
where the operator needs to start using smaller cells to be able to deliver the
required system capacity.

Output power is high enough to support indoor coverage building from


outdoor sites. It is also high enough to drive distributed antenna system for
indoor coverage. It also supports 2TX MIMO.

Supports WCDMA/HSPA services.

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

NSN Flexi BTS System Module rel.2


The Flexi System Module hosts the

telecom control
system operation and maintenance
baseband application
transmission
power distribution functionality.
The System Module can also act as a
System Extension Module operating in a
baseband extension mode.

The following versions of the System


Module are available:

System Module FSMB (rel. 1)


Multimode System Module FSMC (rel. 2)
Multimode System Module FSMD (rel. 2)
Multimode System Module FSME (rel. 2)

Rel. 2 System Modules are LTE ready


29

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS WCDMA rel. 1 interfaces

30

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS WCDMA rel. 2 interfaces

31

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head (FRGG) interfaces

32

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head (FRGQ) interfaces

33

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS - System Modules


BTS Site level
functionality
O&M
Timing/synch
Transport

Baseband
processing

Radio
processing

Flexi Multimode System Module


HW supports following SW operating modes
WCDMA dedicated mode
LTE dedicated mode
WCDMA-LTE concurrent mode under study
Multiband support
RF Modules for different frequency bands can
be connected to same System Module

Flexi EDGE System Module


Performance optimized for single mode operation
18 carrier and 36 carrier variants
Multiband support
RF Modules for different frequency bands can
be connected to same System Module

34

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Exploded view of System Module

35

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FSMB System Module interfaces

36

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FSMB System Module interfaces, cont.


BB processing block (FSP)

Each Rel.1 Flexi Signal Processor FSPA has a capacity of 80 CEs (Channel

37

Elements) Control and Timing block.


Includes the NBAP termination, telecom and overall BTS control functionality, system
O&M functionality, external site support system, and other equipment control.
Generates system reference clock and frequency reference for synchronizing with
other BTS Summing and multiplexing block.
Used for data routing between the radio modules and the baseband RF interface
block.
Responsible for providing output/input interface to or from a maximum of three RF
Modules Baseband extension interface block.
Responsible for providing output/input interface to and/or from the System Extension
Module External interface block.
Implements the external interfaces for controlling external equipment.

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FSMC/D/E System Module interfaces

38

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FSMC/D/E System Module interfaces, cont.


Flexi System Module rel. 2 Baseband (BB) processing.
The Baseband Processor (FSPC, Flexi Signal Processor version C)
terminates the Iub user plane and is responsible for L1 processing of the air
interface.
System Module type FSMC includes one signal processor, FSMD has two
and FSME has three.

The traffic capacities are:


FSMC with 1 FSPC: 240 Ces
FSMD with 2 FSPCs: 576 Ces
FSME with 3 FSPCs: 912 CEs

39

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

System Module interfaces


Connector

40

Type

Purpose

Power supply RF module 1

Multi-beam XL power supply connector

Power delivery to RF1. Fuse rating 20A.

Power supply RF module 2

Multi-beam XL power supply connector

Power delivery to RF2. Fuse rating 20A.

Power supply RF module 3

Multi-beam XL power supply connector

Power delivery to RF3. Fuse rating 20A.


Recommended for I-HSPA use. Can be used for GPS
mediator (FSEG).

Power supply System Extension


Module operating in BB-ext mode

Multi-beam XL power supply connector

Power delivery to System Extension Module operating in


BB-ext mode and to the main fuse for System Modules.
Fuse rating 25A. Can be used for I-HSPA and GPS
mediator (FSEG).

Transmission interfaces

8 x RJ-48/16 x SMB/2 x TNC/1 x duplex LC


connector
2 x RJ-45 connector
1x GE via SFP transceiver

Variable transmission interfaces

10/100/ (1000 for Rel. 2) Eth LMP

RJ-45 connector

For local management tool

10/100/ (1000 for Rel. 2) Eth FPMA

RJ-45 connector

Site support control over IP/site support hard-wired


alarms

10/100/ (1000 for Rel. 2) Eth OVP

RJ-45 connector

External equipment interface with overvoltage protection

1000 Eth ETP (10/100/1000 for Rel. 2)

RJ-45 connector

External transport equipment interface (for I-HSPA


Adapter)

EAC

MDR36 connector

External alarms and controls

Sync out

MDR14 connector

BTS synchronization output interface

Sync in

MDR26 connector

BTS synchronization input interface (for external sources)

OPT-RF 1

Duplex LC connector

Interface for RF Module 1

OPT-RF 2

Duplex LC connector

Interface for RF Module 2

OPT-RF 3

Duplex LC connector

Interface for RF Module 3

OPT-EXT 1

Duplex LC connector

System and baseband extension interfaces

OPT-EXT 2

Duplex LC connector

System and baseband extension interfaces


2

DC input

TX25 screw terminals for 8 25 mm cable

Power feed

Grounding

Screw M5

Grounding
CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FSMB Functional Block diagram

FSPA 1

41

CT10772EN03GLA0

FSPA 2

FSPA 3

2014 Nokia Solutions and Networks. All rights reserved.

FSMB Functional Block diagram, cont.


The System Module can be used as a System Extension Module operating in a
baseband extension mode to add channel capacity. In this case, it is connected to
the master System Module with two optical cables and a DC cable. These items are
provided with Flexi System Extension Kit (FSKA).
The System Extension Kit delivery contains the following items:

Cable set assembly

2 x optical cable

1 x power cable

4 x optical transceiver

Transmission dummy panel.

When the System Module is used as a System Extension Module, the external
synchronization input connectors cannot be used. Synchronization is provided by
the master System Module.
The Rel.1 System Extension Module provides a basic capacity of 32 CE without the
channel capacity license. Enabling more CE capacity for the System Extension
Module requires that a channel capacity license (RAN912 Channel Capacity LK)
with sufficient capacity is downloaded to the BTS.
42

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FSMC/D/E Functional Block diagram

FSPC 1

FSPC 2

FSME only

43

CT10772EN03GLA0

FSPC 3

FSMD+E
only

2014 Nokia Solutions and Networks. All rights reserved.

FSMC/D/E Functional Block diagram, cont.


BTS capacity can be upgraded by adding a second System Module
When the System Module is used as a System Extension Module operating in a baseband extension mode, a transmission
sub-module is not installed. Instead, a dummy transmission sub-module is installed to provide IP55 protection. This item is
also included in Flexi System Extension Kit (FSKA)
The only connectors that can be used are the DC input terminal and the two optical EXT interfaces connected to the System
Module
Synchronization is provided by the System Module.
No commissioning required to integrate FSKA to System Module. FSKA will be detected automatically.
The auto detection requires that WN3.3 or later BTS SW and revision number exists and is active both in the System Module
and System Extension Module. However, support for the FSMC and FSMD is first introduced in WN5.0.
The initial SW upgrade of the Extension System Module is to be done stand-alone and requires a (spare) FTM equipped.
Rel. 2 System Modules can be used in any combination
Rel. 1 System Module (FSMB) can NOT act as an Extension for a Rel. 2 System Module (FSMC/D/E)

44

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Power Distribution and Fuses module (FPFA/B)


DC Input connector
FPFA / B

Type label
Power is distributed from FPFA/B to the System Module. FPFA is used with System
Module rel. 1. In System Module rel. 2, it is replaced with FPFB, which provides more
power feeding capacity to RF Modules. FPFB is compatible with both System Module
releases.
45

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FPFA Interfaces

46

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FPFA Interfaces, cont.


FPFA version A101
Power for the System Extension Module comes through the circuit breaker and can be switched off via the circuit breaker. This
must be done when connecting the Extension module to the System Module to avoid hot-plug connection. This is also required
when disconnecting from the System Module.
When the EXT circuit breaker is pulled to OFF position, the power supply to the Extension module is switched off. Power feed
to the System Module is still on.

FPFA version A102, A103 or later


FPFA versions A102, A103, or later have a common power supply via the same circuit breaker for the System Module and the
System Extension Module. This means that the same circuit breaker switches the power on and off to both the System Module
and the System Extension Module.
The System Module and Extension module are reset by pulling the EXT circuit breaker on/off switch on the front panel.
Note: When connecting the Extension module to the System Module, switch off the circuit breaker to avoid hot-plug connection
to the Extension module. Then switch the System Module back on.
This precaution is also required when disconnecting the Extension module from the System Module.

The fuse rates for the FPFA are:


A.101: RF1-3 20.0A, EXT 25.0A
A.102 or later: RF1-3 20.0A, EXT 25.0A (System Module supplied via EXT circuit breaker)

47

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FPFB Interfaces

48

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FPFB Interfaces, cont.


The FPFB does not have any circuit breakers but instead uses electrical fuses, and includes a dedicated power switch for the
System Module.
There are five membrane switches on the FPFB front panel for the outputs.
The switches control power-control circuits and have two states: On and Stand-by.
This allows to individually connect or disconnect the power supply from each of the 5 possible modules:
RF Module / RRH 1
RF Module / RRH 2
RF Module / RRH 3
System Module
System Extension Module
The fuse rates for the FPFB are:
RF1-3 31.0A (+/-2A), EXT 25.0A (+/- 4.5A)

49

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FPFA/B LED Indication


FPFA LED indication:
LED on:

Load connected to FPFA output and Circuit Breaker (CB) has tripped
Load connected to FPFA output and CB switch pulled to off position
LED off:

Load not connected at all


Load connected to FPFA output and the power supply is on (CB has not
tripped)
FPFB LED indication:
LED colour
Yellow
Green
Red
Yellow,
blinking

Indication
Stand-by, output disabled manually
Normal operation, output enabled
Fault, output disabled
Remote controlled, output disabled *
* not yet supported

Note: All outputs are active by default (e.g. after a DC break)


50

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FPFA/B LED Indication, cont.


Flexi Power Distribution and Fuses (FPFB) is a power distribution unit with over current protection for the
outputs. FPFB distributes nominal -48.0 VDC, also referred to as V48N, to System Module, maximum two System Extension
Modules, three RF Modules and two fans. FPFB is compatible with System Module variants FSMB, FSMC, FSMD and FSME.
System Module variant FSMB supports two System Extension Modules, whereas variants FSMC, FSMD and FSME support
one System Extension Module. FPFB includes also LEDs for output status indications and operating switches for outputs. The
protection class of the FPFB is IP65.
Flexi Power Distribution and Fuses (FPFB) provides following functions

51

Input power connections on the side of FPFB

Four output connections on the front panel of FPFB

One output connection at the bottom of FPFB

One fan connector for two fans at the back of FPFB

Dedicated membrane switch for every RF Module

Dedicated membrane switch for System Extension Module

Common membrane switch for System Module and fan outputs

Surge protection for input lines

Reverse voltage protection

Over Current Protection (OCP) for outputs 1-5

Automatic reset of fuses or over current protections for fan outputs (output 6)

Over Temperature Protection (OTP)

Inrush current limiter

Led indication at the front panel for outputs 1-5

Remote output OFF/ON control for outputs 1-5 through System Module

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio 10 BTS: FSMF

RU40

Multiradio platform for GSM,

WCDMA, LTE
Pay as You Grow -capacity
expansion with extension submodules
Integrated high capacity Ethernet
transport
HW supports up to 96 cells with
System Module chaining
High baseband capacity: HW
supports up to 3 times more
capacity than FSME

10.1 19.7 kg
IP65
-35 to +55 C

High capacity System Module with multiradio capability


For release specific SW capability, see Dimensioning WCDMA RAN: Flexi BTS Baseband
document
52

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio 10 BTS: FSMF, cont.


There are two basic types of HW configuration available in FSM3:
FSMF: FSMF is FSP with three Nyquists, three Turbo Nyquist and MCU (6
core)
FSMG: FSP with two Nyquists and one Turbo Nyquist.
There are different combinations possible of these, also with FSM2 HW, to
fulfill different capacity needs.
There are two LCG configuration types available for System Module Rel. 3 for
HSPA:
Small HSPA configuration
Normal HSPA configuration

53

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Features of Flexi Multiradio Rel 3 System Module


Improved usability

Flexi Multiradio System Module (FSM rel.3) is a new Flexi System Module that supports
LTE / WCDMA and GSM

There are indoor and outdoor variants of FSM rel.3 for optimized deployments

Capacity and technology expansions can be done with sub-modules (Extension


submodules)

High capacity
The latest state-of- the- art processor technology
Increased SM pooling from two to nine SM
Over 10 Gbps site capacity
Larger multiradio and multiband configurations
Increased number RF interfaces from four to six
Enhanced optical interfaces capacity
Improved connectivity
High capacity Ethernet transport integrated in the
System Module
Other transport media with optional integrated
Transport Sub-module

54

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Expansion with Submodules


Capacity and technology expansions can be done with sub-modules (Extension submodules)

Traffic grow or
technology
expansion

Pay as
you
grow

Initial traffic

55

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

High Capacity System Module (1/3)


Increased System Modules pooling from 2 to 9 System Modules

Currently (RU30EP2) up to 2 System Modules can be chained

RF Module

Master SM

RF Module

Extension SM

Flexi Multiradio System Modules enables possibility chaining in the future up to 9 System Modules

RF Module
RF Module

Master SM

RF Module

RF Module
RF Module

RF Module

RF Module

RF Module

Extension SM

Extension SM

Extension SM

Extension SM

Up to 9 SM rel.3 chained (to be implemented in the future)

56

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

High Capacity System Module (2/3)


Overall 10Gbps site capacity

Flexi Multiradio BTS


Site throughput
9 x Flexi
Multiradio

10 Gbps

System Module

10 x more site
capacity

Flexi Multiradio System


Module BTS
1 Gbps

2 x Flexi Multimode
System Module

Traffic data
57

CT10772EN03GLA0

Capacity
2014 Nokia Solutions and Networks. All rights reserved.

High Capacity System Module (2/3)


Larger multiradio and multiband configurations and enhanced optical interfaces capacity

Up to 6 RP3-01 links are available with Flexi Multiradio System Module (FSM rel.3) Core System
Module + 2 Extension Submodules

Core System Module 4 RP3-01 links


Extension Submodule 1 RP3-01 link each

RP3-01 link rate up to 6,133Gbps (32Tx/Rx) *

SM rel.2
configuration

4+4+4
MIMO
carrier
s
(2100)

Triple RF
Module
Triple RF
Module
Triple RF
Module

4+4+4
MIMO
carrier
s
(2100)
4+4+4
MIMO
carrier
s (900)

System
Module rel2
58

SM rel.3
configuratio
n
Triple RF
Module
Triple RF
Module
Triple RF
Module
Triple RF
Module
Triple RF
Module
Triple RF
Module

* Pure HW rel.3
configuration
(System
Module rel.3 +
RF Module
rel.3)

Note that RP3-01 links


are also used for System
Modules connections (1st
RP3-01 link for
synchronization, 2nd RP301 link for antenna data (if
needed))

System
Module rel3
CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

System Module Connectors


DC out
4x

EIF4

EIF2

RJ4
5

SFP

IF4+
8

EIF3

EIF1

RJ4
5

SFP

IF2+
6

RJ4
RJ4
IF3+
IF1+
8
8
7
5
RJ4
8

RJ4
8

FTIF

FPFD
FSMF

DC
out
DC In

LMP

RP3-01

RP3-01

SRIO

RJ45

Or
EIF2

3xSFP

SFP+

16mm

BBext
2

EAC

Sync
Out

HDMI

HDMI

QSFP
BBext
1

SFP

EIF 1

Sync In

RJ45

HDMI

QSFP

FBBA/B
DC in
PwrProfile
59

DC out
PwrProfile

RP3-01
SFP+

QSFP

SRIO
SFP+

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio System Module


System Module capacity

60

Technology

FSMF Capacity

Technology

FBBA Capacity

GSM/ EDGE

72 TRX

GSM/ EDGE

WCDMA

528 CEs

WCDMA

576 CEs

HSDPA

756 Mbps

HSDPA

756 Mbps

HSUPA

115 Mbps

HSUPA

157 Mbps

LTE DL

450 Mbps

LTE DL

450 Mbps

LTE UL

150 Mbps

LTE UL

150 Mbps

LTE BW/Cell

20 MHz

LTE BW/Cell

20 MHz

LTE cell count

LTE cell count

MIMO

Yes (HSPA &


LTE)

MIMO

Yes (HSPA &


LTE)

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi 10 Block Diagram

61

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

System Module rel.3 capacity

Comparing to System Modules rel.2 available capacity of System Module rel.3 does not depend
on number of commissioned cells. Table below presents number of available subunits for traffic use
(or CCCH / interference cancellation processing if needed)

Number
of cells

FSMC

FSMD

FSME

1-3

12

19

46

11

18

79

2 + 1*

9 + 1*

16 + 1*

10 12

1+1*

8 + 1*

15 + 1*

FSMF**
5.5

5 + 0.5*

Table assumes 10km


cell range and 2way
Rx Div

Expansion
Submodule

Available Subunits

FBBA

FBBB

Available resources (subunits) can be used for CCCH processing, HSDPA schedulers processing,
HSUPA users and thr. processing, R99 users processing and interference cancellation processing

Please note that each System Module rel.3 contains CCCH processing resources required for Basic
Configurations (e.g. 6 cells/10km or 3cells/20km 2way Rx Div) included in the System Module rel.3
capacity
One subunit provides 96 Rel.99 CE

In Rel2 hw 1 SU = 48 Ces
62

CT10772EN03GLA0

In Rel3 hw 1 SU = 96 CEs

2014 Nokia Solutions and Networks. All rights reserved.

LCG Configurations
System Module rel.3 LCG configuration

System Module rel.3 might be commissioned to one out of the three configurations:

Rel99 only (up to 12 cells)

Small HSPA configuration (up to 6 cells)

Providing HSPA processing up to 6 HSPA cells (one HSDPA and HSUPA scheduler)

Normal HSPA configuration (up to 12 cells)

Support of UMTS Rel.99 services, no support for HSPA

Providing HSPA processing up to12 HSPA cells (two HSDPA and one HSUPA scheduler)

Large HSPA Configuration

Providing HSPA processing up to12 HSPA cells (two HSDPA and two HSUPA scheduler)

The configuration is commissioned per Local Cell Group (LCG)

Note that LCG commissioning is


optional. By default Normal HSPA
configuration is assumed

63

CT10772EN03GLA0

Note that HSDPA and HSUPA


schedulers are LCG specific

2014 Nokia Solutions and Networks. All rights reserved.

LCG Configurations R99 Only

Number of cells

Core System
Module

1-6 cells
FSMF
7-12 cells

Table assumes 10km


cell range and 2way
Rx Div

Expansion
Submodule

#R99Subunits

FBBA

11

FBBA +FBBA

17

5 + *

FBBA

11 + *

FBBA +FBBA

17 + *

* Additional baseband resources


for CCCH processing needed if
one System Module and more
than 6 cells/10km cell
range/2way Rx div.

Note that 1x CCCH


Processing Set
license for more than
6 cells/10km are
required (CCCH)

64

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

LCG Configurations HSPA

HSPA

Small

Normal

Large

65

Number of
cells

1-6 cells

1-6 cells

1-6cells

FSMF

HSDPA

HSUPA

4 7/8 SU

1 HSPDA scheduler
Upto 6 HSPA cells
Upto 375 active users
Upto 252 Mbps

1 HSUPA Scheduler
Upto 12 HSPA cells
Upto 512 active users
Upto 69 Mbps

3 3/8 SU

2 HSDPA Schedulers
Upto 12 HSPA cells
2x375 active users
Upto 2x256 Mbps

1 HSUPA scheduler
Upto 12 HSPA cells
Upto 512 active users
Upto 69Mpbs

2 6/8 SU

2 HSDPA Schedulers
Upto 12 HSPA cells
2x375 active users
Upto 2x256 Mbps

2 HSUPA scheduler
Upto 12 HSPA cells
Upto 750 active users
Upto 2x69 Mpbs

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

HSPA Resource Steps


HSDPA processing set license

Max number of HSDPA users per


BTS

Max HSDPA throughput per BTS

HSDPA BTS processing set 1

32

7,2 Mbps

HSDPA BTS processing set 2

72

21 Mbps

HSDPA BTS processing set 3

72

84 Mbps

Required number of HSUPA BTS Processing Sets =


max ( Roundup ( Number_of_HSUPA_users / 24) ; Roundup(HSUPA_throughput / 5,8) )
1 HSUPA Processing Step license = 24 users & 5.8 Mbps
8 HSUPA Resourse Steps (1 SU) = 104 users; 25 Mbps

66

#PIC pools

Cells* that are target for


IC

Cells* where the IC is


performed

Consumed SU

12

12

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

NSN Flexi BTS transport sub-module

67

FTM is the integrated


transmission module of the
FlexiBTS

It is mechanically and
electrically connected to the
System Module of the
FlexiBTS

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi System Module + Transport sub-module

68

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTPB PDH (E1,T1, JT1) unit

Interfaces
8 x E1/T1/JT1 balanced (120/100
)
Connector type
1 x RJ48 per IF
Basic functionality
2 ports activated
Licensed features
Activation of additional port pairs,
requires a 2 E1/T1 Port License
per port pair
IMA

69

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTEB PDH (E1) unit

Interfaces
8 x E1 unbalanced (75 )
Connector type
2 x SMB per IF
Basic functionality
2 ports activated
Licensed features
Activation of additional ports,
granularity: 2 ports
IMA

70

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTFA Flexbus unit


Interfaces
2 x Flexbus
Flexbus capacity selectable by SW to
2 x 2 Mbit/s
4 x 2 Mbit/s
8 x 2 Mbit/s
16 x 2 Mbit/s
Connector type
1 x TNC per IF
Accessed through NSN FlexiHub
Manager
Basic functionality
1 Flexbus activated
Licensed features
Activation of the second Flexbus
IMA

71

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTFA applications
The Flexbus interface is used to:

operate NSN FlexiHopper


(Plus)

operate NSN
MetroHopper

72

or to connect to another Indoor Unit like:


FTFA/B
FIFA
FIU19(E)
FXC RRI
IFUE
CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FlexiPacket FirstMile 200i (FPFM200i)

73

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FlexiPacket FirstMile 200i (FPFM200i), cont.


FPFM200i is a NSN FlexiPacket Microwave Radio indoor unit that is designed to fit the transport slot of Flexi Multiradio 10
Base Station System Module. The mechanical integration includes powering of the FPFM200i. The FPFM200i provides
support in the Ethernet uplink and downlink traffic. It provides advanced Ethernet processing features, as well as maximum
flexibility to support TDM traffic via circuit emulation.
The FPFM200i can be connected to outdoor units via a single Ethernet cable, using a copper Ethernet port with power
feeding support. Alternatively, two cables can be used, in which case one of them is a separate power supply cable.
The FPFM200i can be configured, monitored, and administered by a web-based Local Craft Terminal (WebLCT) or NSN
NetViewer management tool. That can be done locally or remotely, via Data Communication Network (DCN).
For more information, see FlexiPacket FirstMile 200 documentation.
The FPFM200i supports the following interfaces:
five electrical Ethernet Ports
10/100/1000Base-TX full duplex
10/100/1000Base-TX auto-negotiation
MDIX (10/100Base-TX)
5 x RJ45 connector (EIF1 ~ EIF5)
2 x P+E ports (EIF4 / EIF5)
four PDH ports on two RJ48C connectors - one RJ48C supports two E1/T1 ports (IF1/3 & IF2/4)
one LMP port on RJ45 connector, 10/100/1000Base-T

74

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FlexiPacket Radio

The FlexiPacket Radio Ethernet performance can be measured in WCDMA BTS Site Manager and NSN FlexiPacket
Microwave Local Craft Terminal.
For the detailed information, please refer to performance management in WCDMA RAN and LCT Operating
Documentation respectively.

75

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTFB interfaces

Flexbus 3
Eth 1 & 2
Connect to
FlexiPacket
microwave
radio.
radio
Connect to an
existing (Gbit)
Ethernet
infrastructure

76

No power
supply
Connect to
other BTSs
Flexbus
interface like:
FTFA/FTFB
FIFA
FIU19(E)
FXC RRI
IFUE

CT10772EN03GLA0

Flexbus 1 & 2
Operate
FlexiHopper (Plus)
Operate
MetroHopper
Connect to other
BTSs Flexbus
interface like:
FTFA/FTFB

FIFA FTFA/FTF
B
FIU19(E)
FIU19(E)
FXC RRI
IFUE FXC RRI
2014 Nokia Solutions and Networks. All rights reserved.

FTFB interfaces, cont.


FTFB can be operated in various modes:
The FlexiHopper radio link can be fully dedicated to either PDH or Ethernet. It can also be operated in Hybrid mode so that
one part of the capacity is used for PDH and the other for Ethernet.
Total capacity offered by FlexiHopper radio is 32 Mbps. The capacity can be assigned to the different traffic types in steps of
2 Mbps.
In case of chaining or co-location, the PDH traffic can be cross-connected at 2 Mbps level towards the other Flexbus
interfaces. In case of Ethernet traffic, aggregation takes place by Ethernet switching.
The 2 GbE ports can be used to create FlexiPacket Radio chains or offload Ethernet to any other Ethernet media.
FlexiPacket radio offers up to 350 Mbps Ethernet throughput.
FTFB supports various microwave radio topologies:
FlexiHopper tail sites
FlexiHopper chain sites
Chain sites with FlexiHopper southbound and FlexiPacket Radio northbound
FlexiPacket Radio chain sites and the evolution from one to the other.
With the 3rd Flexbus interface, all tail & chain site applications above can also be implemented in case of co-location with any
installed Flexbus-enabled NSN BTS.

77

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTJA PDH / Ethernet


Interfaces
4 x E1 unbalanced (75 )
2 x 10/100 Mbit Ethernet
1 optional Gbit Ethernet interface SFP
(Small Formfactor Pluggable)
Connector types
E1: 2 x SMB per IF
Ethernet: RJ45
Basic functionality
2 x E1 ports activated
Basic Ethernet Switching
Licensed features
Activation of E1/T1/JT1 ports 3 & 4

SFP slot

IMA

78

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTIA / FTIB PDH / Ethernet


Interfaces
4 x E1/T1/JT1 balanced (120/100 )
2 x 10/100 Mbit Ethernet (2 x Gbit FTIB
only)
1 optional Gbit Ethernet interface SFP
(Small Formfactor Pluggable)
Connector types
E1: 1 x RJ48 per IF
Ethernet: RJ45
Basic functionality
2 x E1/T1/JT1 ports activated
Basic Ethernet Switching
Licensed features
Activation of E1/T1/JT1 ports 3 & 4
IMA
Timing over packet (FTIB only)
Synchronous Ethernet (FTIB only)
CESoPSN (FTIB only)
79

CT10772EN03GLA0

SFP slot

2014 Nokia Solutions and Networks. All rights reserved.

FTLB PDH / Ethernet


I-HSPA functions as integrated I-HSPA Adapter with I-HSPA ADA3.0 SW
LTE ready for LTE via software upgrade
Interfaces
2 x electrical Gigabit Ethernet, RJ45 (10/100/1000Base-T)
1 x optical Gigabit Ethernet, via optional SFP (e.g. for 1000Base-SX/LX)
4 x E1/T1/JT1 symmetrical, RJ48 (coaxial E1 supported via baluns)
Connector types
E1: 1 x RJ48 per IF
Ethernet: RJ45
Basic functionality
2 x E1/T1/JT1 ports activated
Basic Ethernet Switching
Licensed features
Activation of E1/T1/JT1 ports 3 & 4
IMA
Timing over packet
Synchronous Ethernet
CESoPSN
SFP slot
80

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTOA Optical SDH

Interfaces
1 x STM-1 / OC3
Capacity limited
72448 cps up to RAS06
144896 cps from RU10
Connector type
2 x LC IF

SFP slot

81

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FTHA High-density E1/T1


Interfaces
16 x E1/T1 balanced
Connector types
2 x MDR68 connectors
Application
This high-density E1/T1 unit is intended
for operators that are not using costly
leased lines and therefore need to
backhaul the high HSPA throughputs via a
large number of E1 interfaces
Basic functionality
2 x E1/T1/JT1 ports activated
Licensed features
Activation of additional
E1/T1 interfaces
IMA
82

Support for unbalanced 75 connections is


provided via a configuration change and
commercially available patch panels with coax
connectors of the operator's choice.
FTHA protects investments in legacy MWR
equipment, PWE3 equipment and SDH ADMs, all
offering 16 or more E1/T1 interfaces. Operators, of
this camp, are still able to offer high-speed HSPA
services.

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Transport Sub-modules
Module
name

Interfaces

Availability

Remarks

FTPB

8 x E1/T1/JT1

RAS05.1

120/100/110 , RJ48c

FTEB

8 x E1 coaxial

RAS05.1

75 , SMB

FTOA

1 x STM1/OC3

RAS05.1 ED

1 x SFP, LC equipped

FTJA

4 x E1 coaxial
2 x Fast Ethernet, 1 x GE

RAS06

Optional Gigabit Ethernet interface (SFP)


SMB, RJ45, SFP (LC)

FTIA

4 x E1/T1/JT1
2 x Fast Ethernet, 1 x GE

RAS05.1, Ethernet
supported in RAS06

Optional Gigabit Ethernet interface (SFP)


RJ48C, RJ45, SFP (LC)

2 x electrical Gigabit
Ethernet
1 x optical Gigabit
Ethernet
4 x E1/T1/JT1

RU10

Upgrade to FTIA
Supports Timing over Packet
& Synchronous Ethernet

2 x electrical Gigabit
Ethernet
1 x optical Gigabit
Ethernet
4 x E1/T1/JT1

RU20

Optional Gigabit Ethernet interface (SFP)


RJ48C, RJ45, SFP (LC)
Supports Synchronous Ethernet

FTIB

FTLB

83

FTHA

16 x E1/T1

RU10

2 x MDR68 connectors

FTFA

2 x Flexbus

RAS05.1

TNC

FTFB

2 x Flexbus powered
1 x Flexbus un-powered
2 x Gigabit Ethernet

RU20

3 x TNC
2 x RJ45

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

RF Module

Optional Front and


Back covers

84

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

RF Module, cont.
The RF Module is a stand-alone fully operational transceiver module with integrated antenna filters. The RF Module (Triple PA)
is able to support up to three sectors in a Flexi WCDMA base station.
Radio-related signal processing is performed in the RF Module. It hosts the RF functionality, and also provides power supply and
control for MHAs as well as for antenna RealTilt.
The RF Module has integrated fans and Bias-Ts.
The RF Module can support one to three sectors with the following integrated components:

Transceivers with TX for two adjacent carriers (three transceivers in the Triple RF
module, two in the Dual and one in the Single RF Module)

Transceivers with RX for two adjacent carriers with diversity (three transceivers in the
Triple RF Module, two in the
Dual and one in the Single RF Module)

Linear power amplifiers (three in the Triple RF Module, two in the Dual and one in the Single RF Module)

RF filters with main and diversity branch (three in the Triple RF Module, two in the Dual and one in the Single RF Module)

-48 VDC input power supply

Masthead amplifier and 3GPP Antenna Tilt power feed and control for up to three sectors

Interface to the System Module

Interface for chaining System Modules (Triple RF Module only)

Integrated fan assembly (two fans)

Full operational bandwidth support

Antenna connector interfaces

Readiness for AISG2.0

85

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Dual RF Module exploded view


Four dual-carrier receivers
Two-way uplink diversity for each
receiver
Support for multiple configurations

86

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Dual RF Module exploded view, cont.


The Dual RF Module has two dual-carrier transmitters, and four dual-carrier receivers that
support two dual-carrier branches with 2-way uplink diversity. It can support multiple
configurations.
The Single RF Module is a half-capacity version of the Dual RF Module. It has one TX output
that supports a maximum of two TX carriers (two carriers per TX chain). There is only one RX
input connector as well.
The main and diversity branches include Bias-Ts with lightning strike protectors (Single and
Dual RF Module). The main branch Bias-T is used for Flexi Antenna Line and MHA support.
The diversity branch Bias-T is only used for MHA support. The operating voltages fed via main
antenna line are 0 VDC/ +12 VDC/ +28.5 VDC and via diversity antenna line 0 VDC/ +12 VDC.
The main branch also includes an Antenna Line VSWR Monitor (power meter for forward and
reflected voltage ratio measuring). The VSWR monitoring system is used for producing alarms
for the antenna line condition based on the alarm thresholds (Single and Dual RF Module).
As a default setting, the minor alarm will be generated when the VSWR is 1.9 and the major
alarm (cell down) will be generated when the VSWR is 2.6. However, it is possible to adjust
both minor and major alarm thresholds within the range 1.5 3.5. The antenna line does not
provide any alarms without a valid license (Line Supervision RAN907LK).

87

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Dual RF Module interfaces

Front panel connector


Power supply
Grounding
Operational state visual indication
Antenna connector 1
Antenna connector 2
Optical interface

88

Connector type
Screw terminal
Screw terminal
2 x tri-colour LED
7/16 type, female
7/16 type, female
Duplex LC connector

CT10772EN03GLA0

Purpose
Power delivery
Grounding
Operational state and fan status indication
RF signal interface to antenna
RF signal interface to antenna
Control interface to the System Module

2014 Nokia Solutions and Networks. All rights reserved.

Dual RF Module functional block

ANT1
ANT2
ANT4
ANT3

89

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

RF Module delivery content

RF Module sales item includes following 5 components to connect it to System


Module
RF Module (including casing and fan subassembly)
2.0 meter long IP55 protected outdoor cable for 48 V DC
2.0 meter long IP55 protected outdoor multimode optical system cable
4 Gbps OBSAI optical RP3-01
UL & DL in the same cable pair
Two pluggable SFP optical transceivers, one to System and other one to RF
Module
4.) SFP optical transceiver (2pcs)
(SFP=Small Form factor Pluggable)

2.)

1.)

DC cable, 2m
Optical cable, 2m

3.)

90

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Triple RF Module exploded view


Three independent transceivers with 1 PA

91

and 2 WCDMA carriers each


New Multimode Modules with 34 WCDMA
carriers per MCPA (Multi Carrier Power
Amplifier)
One transmitter chain and 2 independent
uplink chains per transceiver
Three duplex filter blocks
Six antenna connectors

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Triple RF Module interfaces (Multiradio versions)

92

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Multiradio Triple RF Module functional block


ANT
1
2
4
3
6
5

93

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi 3-Sector RF Module 850 15MHz BW (FXCA)


SW Definable Radio for GSM, WCDMA and LTE Operation

Industry leading Integration level


3x70W power amplifiers
3x60W at the antenna connector
WCDMA configurations up to 3+3+3
HW supports chaining of the radios
Concurrent operation btw. GSM, WCDMA and LTE defined by SW
LTE and GSM support: please refer to LTE and GSM/EDGE roadmaps
Sector 3
Div Rx Tx60W/Rx

Rx Out

94

Sector 2
Div Rx Tx60W/Rx

Sector 1
Div Rx Tx60W/Rx

Rx Out
CT10772EN03GLA0

Flexi
RU20

25 liters
25 kg
3 height units
IP65
-35 to +55 C

Rx Out
2014 Nokia Solutions and Networks. All rights reserved.

Flexi 3-Sector RF Module 900 20MHz BW (FXDA)


SW Definable Radio for GSM, WCDMA and LTE Operation

Industry leading Integration level


3x70W power amplifiers
3x60W at the antenna connector
WCDMA configurations up to 4+4+4
HW supports chaining of the radios
Concurrent operation btw. GSM, WCDMA and LTE defined by SW
LTE and GSM support: please refer to LTE and GSM/EDGE roadmaps
Sector 3
Div Rx Tx60W/Rx

Rx Out

95

Sector 2
Div Rx Tx60W/Rx

Sector 1
Div Rx Tx60W/Rx

Rx Out
CT10772EN03GLA0

Flexi
RU20

25 liters
25 kg
3 height units
IP65
-35 to +55 C

Rx Out
2014 Nokia Solutions and Networks. All rights reserved.

Flexi 3-Sector RF Module 1500 10MHz BW (FRKA)


SW Definable Radio for WCDMA and LTE Operation

Industry leading Integration level

Flexi

3x70W power amplifiers


3x60W at the antenna connector
WCDMA configurations up to 2+2+2
HW supports chaining of the radios
Concurrent operation btw. WCDMA and LTE defined by SW
LTE support: please refer to LTE roadmap
Sector 3
Div Rx Tx60W/Rx

96

Sector 2
Div Rx Tx60W/Rx

Sector 1
Div Rx Tx60W/Rx

CT10772EN03GLA0

RU20

25 liters
25 kg
3 height units
IP65
-35 to +55 C

2014 Nokia Solutions and Networks. All rights reserved.

Flexi 3-Sector RF Module 1.7/2.1 20MHz BW (FRIE)


SW Definable Radio for WCDMA and LTE Operation

Industry leading Integration level

Flexi

3x70W power amplifiers


3x60W at the antenna connector
WCDMA configurations up to 4+4+4
HW supports chaining of the radios
Concurrent operation btw. WCDMA and LTE defined by SW
LTE support: please refer to LTE roadmap
Sector 3
Div Rx Tx60W/Rx

Rx Out

97

Sector 2
Div Rx Tx60W/Rx

Sector 1
Div Rx Tx60W/Rx

Rx Out
CT10772EN03GLA0

RU20

25 liters
25 kg
3 height units
IP65
-35 to +55 C

Rx Out
2014 Nokia Solutions and Networks. All rights reserved.

Flexi 3-Sector RF Module 2100 20MHz BW (FRGP)


SW Definable Radio for WCDMA and LTE Operation

Industry leading Integration level

Flexi

3x70W power amplifiers


3x60W at the antenna connector
WCDMA configurations up to 4+4+4
HW supports chaining of the radios
Concurrent operation btw. WCDMA and LTE defined by SW
LTE support: please refer to LTE roadmap
Sector 3
Div Rx Tx60W/Rx

Rx Out

98

Sector 2
Div Rx Tx60W/Rx

Sector 1
Div Rx Tx60W/Rx

Rx Out
CT10772EN03GLA0

RU20

25 liters
25 kg
3 height units
IP65
-35 to +55 C

Rx Out
2014 Nokia Solutions and Networks. All rights reserved.

Flexi 3-Sector RF Module 1900 20MHz BW (FXFA)


SW Definable Radio for GSM, WCDMA and LTE Operation

Industry leading Integration level


3x70W power amplifiers
3x60W at the antenna connector
WCDMA configurations up to 4+4+4
HW supports chaining of the radios
Concurrent operation btw. GSM, WCDMA and LTE defined by SW
LTE and GSM support: please refer to LTE and GSM/EDGE roadmaps
Sector 3
Div Rx Tx60W/Rx

Rx Out

99

Sector 2
Div Rx Tx60W/Rx

Sector 1
Div Rx Tx60W/Rx

Rx Out
CT10772EN03GLA0

Flexi
RU20

25 liters
25 kg
3 height units
IP65
-35 to +55 C

Rx Out
2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS - Remote RF Heads


BTS Site level
functionality
- O&M
- Timing/synch
- Transport

Baseband
processing

Radio
processing

Flexi RRH
40+40 W
MIMO support
HW supports GSM, WCDMA and LTE
operation at relevant frequency bands
Single-band, Multi-carrier operation
HW supports following SW operating modes
Dedicated SW modes: GSM, WCDMA, LTE
GSM-WCDMA concurrent mode
WCDMA-LTE concurrent mode
GSM-LTE concurrent mode
GSM-WCDMA-LTE concurrent mode

100

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head

There are three versions of the


Remote Radio Head module:
RRH 2100 60W FRGG (RU10)
RRH 2100 2x40W FRGQ
(RU20)
RRH 900 2x40W FHDA (RU30)
There are also two older versions of
RRH: FRGE & FRGN RRH 2100
40W (RAS06)
# TX/RX connectors
# RX connectors
# carriers
101

CT10772EN03GLA0

FRGG

FRGQ/FHDA

2
(3 HW prepared)

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head, cont.


The Remote Radio Head hosts the RF functionality and provides control and
power supply to the Flexi Antenna Line. The RRH has one TX output that
supports a maximum of two TX carriers (two carriers per TX chain), as well as
one RX input connector.
The Remote Radio Head (RRH) has the following properties:
Optional external AC/DC converter module
DC power supply for 48 VDC
Integrated Over Voltage Protection (OVP)
External alarms.
The functionality of the RRH is similar to the functionality of the Single RF
Module, with the exception that the RRH does not have any fans or Bias-Ts, and
does not support MHAs.
The RRH supports the VSWR monitoring system and is AISG2.0 compatible.

102

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head interfaces (FRGG)

103

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head connectors (FRGG)

Connector

104

Connector type

Purpose

Power supply

ITT Cannon 2 pin + screw


terminal

Power delivery

Grounding

M8, 2 x M5

Grounding

Operational state
visual indication

2 x LED

Operational state indication (Status:


3-colour LED, RF on: 2-colour LED)

Antenna connector
1

7/16 type, female

RF signal interface to antenna(s)

Antenna connector
2

7/16 type, female

RF signal interface to antenna(s)

Optical interface

Multi-mode (200 m w OBSAI) or


single-mode (up to 40 km) fiber
interface

Control interface to the System


Module

EAC connector

Amphenol C 091 D series (14


pin)

External alarm

RET

Amphenol C 091 D series (8 pin)

Remote electrical tilt

LMT

RJ-45 (LAN)

Local maintenance

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head FRGG block diagram

Ant 1

Ant 2

105

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head interfaces (FRGQ)

106

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head Block Diagram (FRGQ)

107

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi RRH 2TX 900 (FHDA)

Flexi
RU30

SW Definable Radio for GSM, WCDMA and LTE Operation

2x40W at the antenna connector


Optimized for single sector deployment and MIMO
Convectional cooling
Up to 4 WCDMA carriers per sector
Concurrent operation btw. GSM, WCDMA and LTE
defined by SW
LTE and GSM support: please refer to LTE and
GSM/EDGE roadmaps

18 kg
31 liters
IP65
-35 to +55 C
*) dimensions without solar shield

108

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

RF Module Versions

109

Remarks

Flexi HW
release

Dual 50 W 1700/2100

Module

FRIB

Single 50 W 1700/2100

Module

FRGC

Dual 50 W 2100

Module

FRGD

Single 50 W 2100

Module

FRGJ

Dual 50 W 2100

Module

FRGK

Single 50 W 2100

Module

FRGL

Dual 50 W 2100

Module

FRGM

Single 50 W 2100

Module

FRCA

Dual 50 W 850

Module

FRCB

Single 50 W 850

Module

FRDA

Dual 50 W 900

Module

FRDB

Single 50 W 900

Module

FRFA

Dual 50 W 1900

Module

FRFB

Single 50 W 1900

Module

Version

Description

FRIA

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

RF Module Versions (cont.)

110

Remarks

Flexi HW
release

3-sector 70 W 2100

Module 10 MHz (RU10)

FRGP

3-sector 70 W 2100

Multiradio Module 20 MHz (RU20)

2.2

FXFA/B

3-sector 70 W 1900

Multiradio Module 20 MHz (RU20)

2.2

FRKA

3-sector 70 W 1500

Multiradio Module 10 MHz (RU20)

2.1

FRIE

3-sector 70 W
1700/2100

Multiradio Module 20 MHz (RU20)

2.2

FXCA

3-sector 70 W 850

Multiradio Module 15 MHz NEW in


RU30

2.2

FXDA

3-sector 70 W 900

Multiradio Module 20 MHz NEW in


RU30

2.2

FXEA

3-sector 70 W 1800

Multiradio Module 20 MHz NEW in


RU30

2.2

FXFB

3-sector 70 W 1900

Multiradio Module 20 MHz NEW in


RU30

2.2

FXCB

3-sector 90 W 850

Multiradio Mobule 25 MHz New in


RU40

2.2

FXDB

3-sector 90 W 900

Multiradio Mobule 35 MHz New in


RU40

2.2

FXEB

3-sector 90 W 1800

Multiradio Mobule 35 MHz New in


RU40

2.2

FXFC

3-sector 90 W 1900

Multiradio Mobule 25 MHz New in


RU40

2.2

Version

Description

FRGF

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Remote Radio Head Versions

111

Remarks

Flexi HW release

1TX 70 W 2100

1 TX (2 carriers), 2 RX (RU10)

FRGQ

2TX 2x40 W 2100

2 TX (4 carriers), 2 RX (RU20)

2.x

FHDA

2TX 2x40 W 900

2 TX (4 carriers), 2 RX NEW in RU30

2.x

FHEA

2Tx 2x40W 1800

2TX (4 carriers), 2 RX New in RU40

2.x

FHDB

2TX 2x60 W 900

2TX (4 carriers), 2 RX New in RU40

2.x

FHEB

2TX 2x60 W 1800

2TX (4 carriers), 2 RX New in RU40

2.x

Version

Description

FRGG

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio Antenna System

112

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio Antenna System, cont.


The Flexi Multiradio Antenna System is the next step in the evolution of radio
networks, providing higher capacity and coverage while reducing site costs. The
NSN Multiradio Antenna System enhances mobile network performance by
integrating the base stations radio frequency elements into the antenna. Flexi
Multiradio Antenna System provides an alternative to Flexi RF Modules and
RRHs, or can be used in combination with traditional Flexi RF units.
The Flexi Multiradio Antenna System is a complete radio unit with integrated
antenna arrays, transceivers, power amplifiers, and filter modules, including the
integrated Common Module (CM) for processing the Active Antenna System
(AAS) specific functions. The integrated antenna array supports active and
passive combinations.

113

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Functional Architecture of AAS

114

Version

Descriptio
n

Active Frequency
Band

Passive Frequency
Band

Flexi HW
release

FAGF

2TX 2x40W

2100

1800

FAGP

2TX 2x40
W

2100

900

2.x

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Functional Architecture of AAS, cont.


An Active Antenna module is a stand-alone, fully operational multi-transceiver antenna module. It provides full radio
functionality including transmitter, receiver, and antenna parts as, well as related digital signal processing functions.
The active antenna module consists of the following sub-modules:

Common sub-module (CM)

Active Element (AE) sub-modules (4 pcs)

Antenna sub-module

Electro-mechanics.

Common sub-module
The Common sub-module (CM) is an integrated part of an Active Antenna; it interconnects active elements of an active
antenna to the Flexi Multiradio System Module or to another active antenna or Radio Remote Head (RRH) in the same chain.
The CM is mainly responsible for the following functions:

O&M tasks for the Active Antenna

distributing of power supply

downloading and storing software (SW)

generating and distributing of a clock (over RP3-01)

Beamforming

measuring power of radiation pattern (beams)

terminating external interfaces (optical RP3-01, LED control, EAC)

providing four internal RP3-01 interfaces towards active elements (used for internal communication between CM and AEs).

115

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Functional Architecture of AAS, cont.


Active Element sub-module
The Active Element sub-module performs the following tasks:

RP3-01 interface processing

Air interface timing; phase and amplitude control

RF processing

RF BB processing

Performing the analog-digital and digital-analog conversions

Providing RF interfaces for two cross-polarized antennas

Antenna sub-module
The Antenna sub-module is responsible for the following tasks:

Provides a highly efficient, cross-polarized, single or combined antenna radiator structure with the desired horizontal and
vertical pattern beam width

Provides cross-polarized RF inputs for the passive band antenna array

Provides an integrated RET functionality and RET interfaces for the passive antenna array.

Electro-mechanics
The Electro-mechanic parts are an enclosure for the electrical sub-modules meeting the environmental requirements. It is
responsible for the following functions:

Provides electrical and mechanical interfaces

Cools the modules

Meets an IP65 classification standard

116

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

AAS Interfaces
AISG/ RET
Connectors

Passive Antenna
Ports

LED
Indicator
s

DC Input

117

CT10772EN03GLA0

EA
C

RP3-01 Optical
connectors
2014 Nokia Solutions and Networks. All rights reserved.

AAS Interfaces, cont.


AAS has the following interfaces:

118

Open Base Station Architecture Initiative (OBSAI) interface to active array

Two SFP Connectors, second port is HW prepared for chaining

RP3-01, Bit Rate 3.072 Gbit/s and 6.144 Gbit/s support

Management interfaces

External Alarm Connection (EAC)

DC Interfaces to active array

DC Input Voltage

Reverse Polarity Protection

Remote Electrical Tilt (RET / AISG)

Two passive antenna ports

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

WCDMA Flexi BTS variants (FRGJ/K) support NSN


TMAs and RET Antennas
WCDMA Flexi BTS variants (FRGJ/K) can be used in
installation cases with NSN TMAs and Antennas
(Andrew, Kathrein and Powerwave )
FRGJ/K HW supports high gain TMA (24 dB), alarm
handling by Motorola interface and AISG1.1/2.0

AISG = Antenna
Interface Standards
Group. 3GppAL
interface is defined
based on AISG
interface.

TMA (24dB)

FRGJ/K SW support available


FRGJ: Dual RF module,
FRGK: Single RF module.
Both 2.1 GHz
FRGJ/K HW supports NSN TMAs with RET that
require AISG1.1

Note: All NSN antenna system products are


supported by the Rel.2 Radio Modules as well.

119

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

0 tilt
14 tilt

A type sector/ antenna configuration

120

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Dual PA RF Module signal path: A type


configuration
feedback
TX 1
TX 2
RF - DE

Sector 1
PA

RX 1 M

ANT 1

RX 2 M
RX 1 D
RX 2 D
ANT 2
RX switch

feedback

Sector 2
TX 3
TX 4

PA

RX 3 M

ANT 3

RF - DE
RX 4 M
RX 3 D
RX 4 D

ANT 4
RX switch

121

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

A type sector/ antenna configuration

122

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Dual PA RF Module signal path: A type


configuration
feedback
TX 1
TX 2
RF - DE

Sector 1
PA

RX 1 M

ANT 1

RX 2 M
RX 1 D
RX 2 D
ANT 2
RX switch

feedback

Sector 2
TX 3
TX 4

PA

RX 3 M

ANT 3

RF - DE
RX 4 M
RX 3 D
RX 4 D

ANT 4
RX switch

123

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

B type sector/ antenna configuration

124

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Dual PA RF Module signal path: B type


configuration
feedback
TX 1
TX 2
RF - DE

Sector 1
PA

RX 1 M

ANT 1

RX 2 M
RX 1 D
RX 2 D
ANT 2
RX switch

feedback
TX 3
TX 4

PA

RX 3 M

ANT 3

RF - DE
RX 4 M
RX 3 D
RX 4 D

ANT 4
RX switch

125

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

A type COC with 1 Dual and 1 Single PA Module

126

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Triple PA RF Module signal path: A type


configuration (only 1 PA branch shown)
TX1

PA

TX2
RF loop
RX1 M
ANT 1

opt. IF
RF
contr
ol

RX2 M
RX1 D
RX2 D
RX switch

ANT 2

ANT 3

127

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Triple RF Module 3-sector A type configuration

128

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Triple PA RF Module signal path: C type


configuration (example shows one 2-TRX sector)
TX1
PA
RF
loop

RX1 M
opt. IFs

RF
control

ANT 1

RX2 D
RX switch

ANT 2

RF Module 1

TX2
PA
RF
loop

RX2 M
opt. IFs

RF
control

ANT 1

RX1 D
RX switch

ANT 2

RF Module 2

129

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Triple RF Module 3-sector C type configuration

130

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Appendix
Optional Item Description

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Power Module FPMA


Example configuration with:
1 x Flexi Power Module FPMA
3 Flexi Power AC/DC sub-modules FPAA (230V AC 48V DC)
1 Flexi Power Battery FPBA

48V
DC
output
to BTS

+
-

AC
input
cabling
to
FPMA

132

CT10772EN03GLA0

AC feed
to FPAA
(3pcs)

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Power Module FPRA

133

High power alternative to FPMA


Up to 3 rectifiers
Output power 2 kW per rectifier, 6 kW total DC output power
External batteries supported (no internal battery support)

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Power DC/DC Module (FPDA)

134

Converts nominal 24V DC input voltage to 53-55V DC output voltage


A maximum of two FPDA modules can be connected in parallel
Integrated self-controlled fan
Maximum DC output power is 2 kW

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

FPAB

135

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Power AC/DC Module (FPAB)

136

Flexi Power AC/DC sub-module


100/240V (FPAB) is a rectifier assembly
that converts AC input voltage to DC
output voltage (56V DC)

The main application for the FPAB is to


operate as an AC/DC converter for the
single RF Module of the Flexi WCDMA
BTS

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi WCDMA BTS power consumption


Flexi WCDMA BTS
with
FRGC/FRxA &
FRGD/FRxB &
FSMB &
FTEB/FTPB
transmission
sub-module
@ W per carrier
1 carrier omni
@ min. 20 W
1+1+1
@ min. 20 W

Estimate of Typical BBU time (23 C)


with typical 50 % load and
new batteries

Power consumption
[W]
48 VDC input at 23 C
Estimate
Typical
50 %
load

Worst
Max
100 %
load

92 Ah separate
Battery with
MIBBU

62 Ah
separate
Battery with
MIBBU

250

300

16 h

11 h

up to 120 minutes (3 FPBA)


up to 40 minutes (1 FBPA)

630

7 h 30 min

5h

up to 59 minutes (3 FPBA)
up to 20 minutes (1 FBPA)

510

FPMA & FPBA with


FPAA (Note 1)

1+1+1
@ min 40 W

660

850

5 h 30 min

4h

up to 46 minutes (3 FPBA)
up to 15 minutes (1 FBPA)

2+2+2
@ min. 20 W

660

850

5 h 30 min

4h

up to 46 minutes (3 FPBA)
up to 15 minutes (1 FBPA)

2+2+2
@ min 40 W per carrier

1180

1530

3 h 15 min

2 h 15 min

up to 17 minutes (2 FPAA+ 2
FPBA)

4+4+4
@ min 20 W per carrier

1180

1530

3 h 15 min

2 h 15 min

up to 17 minutes (2 FPAA+ 2
FPBA)

Note 1:
One FPAA can support 1 kW of 48 DC power.
One FPBA can support 1 kW of 48 V DC for about ten minutes at normal operational conditions.
FPBA charging : min 5 W, typical max 55 W , absolute max 110 W (with empty FPBA)

137

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi WCDMA BTS operating temperatures &


voltages
System
Module
FSM

Property

Two PA RF
One PA RF
Module FRGA Module FRGB

High ambient air temperature


limit

+50 C

High ambient air temperature


limit with sun radiation heat load

+45 C

Nominal DC voltage

Power
Module FPMA

48 V DC

Permitted DC operating voltage


fluctuation (external supply
range)

40.5 57 V DC

Optional Nominal DC voltage


with DC-DC Module

+24 V DC
(with Release 2 HW module FPDA)

Optional Permitted 24 V DC
operating voltage fluctuation
(external supply range)

+18 +32 V DC
(with Release 2 HW module FPDA)

Nominal AC voltage with


optional AC Module

240 V (US 1-phase)


230 V (EU 1-phase)
202 V (Japan delta)

Optional Permitted AC operating


voltage and frequency
fluctuation (external supply
range)

138

184 276 V
45 66 Hz
0 184 V , 520 minutes when using FPBA with FPAA
(time depends on AC Voltage input)

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi mounting kit for floor, wall and pole (FMFA)

139

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi mounting kit for floor, wall and pole (FMFx)


FMFA version 470149A.104
has support for total of six
pieces of single-hole grounding
lug.
FMFA version 470149A.105
Six pieces of M5 threaded
holes have been add to FMFA
version 470149A.105 to
support usage of dual-hole
grounding lug (shown).

140

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi External Alarm Box (FSEB)

141

Support for the fire detector

IP55 protection

CT10772EN03GLA0

Extending the Flexi BTS alarm


connector to support up to 24 alarm
interfaces

12 alarms are supported for Flexi


WBTS

2014 Nokia Solutions and Networks. All rights reserved.

GPS for Flexi BTS: WCDMA and I-HSPA

Flexi BTS RF Modules

Flexi BTS System Module


to FSMC/D/E
-48VDC

PPS

to FSMB
Mediator FSEG

142

Trimble Acutime Gold: GPS antenna with inbuilt receiver


Available with Flexi WCDMA BTS and Flexi I-HSPA BTS
Power, sync signal and data connection to BTS System Module
Rel. 2 System Modules (FSMC/D/E) allow direct connection of the GPS without
Mediator
CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

GPS Mediator FSEG


Flexi System External GPS Mediator (FSEG) is used to provide an IP55 protected space for powering and
connecting the GPS module (GPS Antenna Kit FYGA) to the BTS system.
FSEG is only used with the FSMB when GPS synchronization is needed. No specific software is needed for
running the FSEG.
FSEG has the following functionalities:

Transforming operating voltage to FYGA (from -48VDC to +12VDC)

Mediating GPS clock signal from FYGA to the BTS system

Overvoltage protection
FSEG can be installed in the following ways:

On a wall (vertical or horizontal position, using existing screw holes)

On a pole using brackets (horizontal or vertical position, using optional Flexi Pole Installation Kit FPIA)

On stack installations using brackets (horizontal or vertical position, using optional Flexi Mounting
Auxiliary Brackets FMAA)

On the FCIA or FCOA roof (horizontal position only)

In outdoor applications, the FSEG can be attached to the outdoor cabinet roof (a maximum of one
item can be installed next to the FSEG). There are fixing points for the FSEG in the outdoor cabinet.

In indoor applications, the FSEG can be attached to the indoor cabinet roof. In stacked applications,
the FSEG is mounted in the proximity of the BTS.

FSEG can be installed either horizontally (cable lead-ins on the side) or vertically (cable lead-ins facing
down)

143

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Cabinet for Indoor (FCIA)


Made of an aluminium chassis enclosed with
aluminium doors and sides

Does not carry any electrical functionality


No traditional backplanes or electronics. The cable
entries are located at the top of the cabinet

External cables are connected directly to the Flexi


modules inside the cabinet
The following optional modules can be mounted to the
FCIA cabinet:

Integrated long term battery backup solution


(MIBBU)

Flexi Rectifier Module (FRMx)


EAC connection box (FSEB)
Overvoltage protection box (FSEC)

144

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Cabinet for Outdoor (FCOA)


Made of an aluminium chassis enclosed with
aluminium covers
Triangle door-open key
Does not have any electrical functionality
Does not increase Flexi BTS site power
consumption
The cabinet has the following functions:
Provides the base station and cables
protection against external damage and
foreign objects
Supports earthquake protection
Houses the Flexi cabinet site support module
(FCSA) that provides long-term battery backup and a 4U-high IP55-protected space for
Line Terminal Equipment (LTE)
Together with Flexi cabinet air filter (FCFA), it
protects the BTS in extremely dirty conditions

145

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Air Filter (FCFA)

146

The optional air filter (FCFA) can be added


in case of extremely dirty environment (for
fresh-air-cooled modules) to provide
protection against extremely dirty conditions
by over-pressurizing the cabinet

It consists of a filter element, 8 x diagonal


fans, a pressure sensor, control logic, and
back-wall mechanics

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Site Support Module (FCSA)

147

Provides long-term battery back-up


time for the Flexi WCDMA BTS and
a space for installing Line Terminal
Equipment (LTE) units

IP55 protected installation space


for the PDU unit, IBBU AC interface
box, rectifier units, LTE equipment,
control card, heat exchanger, and
fans

Batteries are fixed and cabled


using Flexi Mounting Kit for
Batteries (FMBA)

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Mounting Shield (FMSA/B)

Flexi Mounting Shield (FMSA/FMSB) is an


outdoor cabinet for a stacked Flexi BTS. Used
instead of the plastic front and rear covers, it
provides protection against solar load, large
insects and slight vandalism
Flexi Mounting Kit Floor/Wall/Pole (FMFA) is
required for both cabinets

6U FMSA
18U FMSB

148

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi mounting kit vertical for 2G (FMUA)


To enable Flexi BTS Modules to be
installed in existing GSM/EDGE UltraSite
sites :

UltraSite EDGE BTS (CRMA)


UltraSite Indoor cabinet (IDCA 101)
UltraSite Outdoor cabinet (ODCA
101)

149

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi mounting kit horizontal for 2G (FMUB)

To enable Flexi BTS Modules to be


installed in existing GSM/EDGE UltraSite
sites :
UltraSite Indoor cabinet (IDCA) v.202
or newer
UltraSite Outdoor cabinet (ODCA)
v.202 or newer
UltraSite EDGE Outdoor cabinet
(ODCF)
The mounting kit consists of a rack that can
support, for example, one WCDMA System
Module, up to three WCDMA RF Modules,
and one FPMA or System Extension
Module or FPDA, and cables.

The space requirement for 5 x 3U


modules is 15U
150

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

System Module LEDs (from left to right)

151

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

System Module LEDs (from left to right), cont.


The System Module has seven tri-color LEDs on the front panel to indicate the
operational status of the module and all fault conditions during operation.
It is recommended that you read the information on the LED indications carefully.
A blinking red LED does not always require removing of the module.

152

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

DC output connector and DC input

Power chaining output connectors' pin map and DC input connector pin map.

153

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

LMP connector pin map

154

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

SFP connector pin map

155

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Broadband extension connector pin map

156

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

External Ethernet transport connector pin map

157

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

EAC connector pin map

158

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

External synchronization input connector pin map

159

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

External synchronization input connector pin map,


cont.
Signal descriptions:
GPS_TIME_IN_H, GSM_FC_IN_H, GPS_TIME_IN_L, GSM_FC_IN_L: serial
data from GPS to CPU or GSM Frame Clock input; RS422/485 differential
SingleEndedIn: REF2M_IN REF10M_IN Accepts TTL/CMOS and SINE from -6 to
+13 dBm. Input impedance is approximately 75 Ohm, Reduced swing TTL
resulting from TTL-Gate plus 75 Ohm source termination is OK, too.
NC: No Connection
GPS_PPS_IN_H, GSM_FN_IN_H, GPS_PPS_IN_L, GSM_FN_IN_L: PPS pulse
from GPS or GSM Frame Number input; RS422/485 differential
GPS_CONTROL_H, GPS_CONTROL_L: Serial data form CPU to GPS;
RS422/485 differential.
GPS_PWR, GPS_PWR_RET: GPS power supply: 50 mA at 15 to >35 V
GPS_PWR_N might not be isolated from GND but cannot be relied upon to be
the same.

160

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

External synchronization output connector pin


map

161

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

External synchronization output connector pin


map, cont.
Signal descriptions:

GPS_TIME_OUT_H, GSM_FC_OUT_H, GPS_TIME_OUT_L, GSM_FC_OUT_L:

Copy of the serial data from GPS to CPU. The collocated BTS is only interested in the NMEA contents of this data stream
or GSM Frame Clock output; RS422/485 differential or Frame clock out

162

SingleEndedClockOut1: LVTTL. Can have 11 sources: 2.048 MHz (from SingleEndedIn), 10 MHz (from SingleEndedIn),
10 MHz (FPGA internally generated), FCLK_IN 250 Hz, SYNC_WFCLK 30.72 MHz, SYNC_SFCLK 100 Hz,
SYNC_SFCLK/2 50 Hz, SYNC_SFCLK/4 25 Hz, SYNC_SFCLK/8 12.5 Hz, SFNO 30.72 MHz pulse per 10 ms, Internal
PPS_int 1 Hz

PPS_OUT_H, PPS_OUT_L: PPS_OUT RS422/485 differential

SingleEndedClockOut2: LVTTL. Can have two sources: 2.048 MHz (from SingleEndedIn), 10 MHz (from SingleEndedIn)

DiffClockOut_H or GSM_FN_OUT_H, DiffClockOut_L or GSM_FN_OUT_L: Has 12 potential clock sources: 2.048 MHz
(from SingleEndedIn), 10 MHz (from SingleEndedIn), 10 MHz (FPGA internally generated), FCLK_IN 250 Hz,
SYNC_WFCLK 30.72 MHz, SYNC_SFCLK 100 Hz, SYNC_SFCLK/2 50 Hz, SYNC_SFCLK/4 25 Hz, SYNC_SFCLK/8
12.5 Hz, SFNO 30.72 MHz pulse per 10 ms, Internal PPS_int 1 Hz, GSM FRAME number

HARQ: DSP signal from FSPD

TESTCLK_GSM_FN_OUT_H: Single ended copy of pins 10/12

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS System Module hardware


product generations

163

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS RF Module hardware product


generations 1/4

164

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS RF Module hardware product


generations 2/4

165

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS RF Module hardware product


generations 3/4

166

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Flexi Multiradio BTS RF Module hardware product


generations 4/4

167

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Abbreviations
General policy for abbreviations:
1st letter

F for Flexi

2nd letter
A for Antenna Equipment and Same Band Combiner

FACA

Same Band combiner with TX summing for 850

FADA

Same Band combiner with TX summing for 900

FAEA

Same Band combiner with TX summing for 1800

FAFA

Same Band combiner with TX summing for 1900

FCDA

Flexi Cabinet Smoke Detector

FCFA

Flexi Cabinet Air Filter

FCHA

Flexi Cabinet Heater

D for Diplexers

FCIA

Flexi Cabinet for Indoor (Epsilon program design


item)

R for Radio Modules

FCOA

Flexi Cabinet for Outdoor

S for System Modules

FCSA

Flexi Cabinet Site Support Module

FDIA

Diplexer for 1.7/2.1/1900

B for Baseband Extension Modules

FLIA

Dual Wide band Mast Head Amplifier

T for Transport Modules, Sub modules and Cables

FMCA

Flexi 3U Mounting Covers front and back

FMCB

Flexi 2U Mounting Covers front and back (Epsilon


program design item

FMFA

Flexi Mounting Kit for Floor and wall and pole

FMUA

Flexi Mounting Kit Vertical for 2G

C for Cabinet and Cabinet Accessories

FMUB

Flexi Mounting Kit Horizontal for 2G

L for low noise Mast Head Amplifier

FPAA

Flexi Power AC/DC sub-module 230 V

FPAB

Flexi Power AC/DC sub-module 230V

FPBA

Flexi Power Battery sub-module

FPDA

Flexi Power DC/DC Module 24 V (Epsilon program


design item)

FPMA

Flexi Power Module

P for Power Supply Modules and Sub modules


M for Mounting Kits

3rd Application or usage or frequency band (RF and Mast Head


Amplifiers)
4th for version A is the first one, future B, C...

168

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Abbreviations
FR__

Flexi RF Module codes


A = 400 MHz
B = 700 MHz
C = 850 MHz
D = 900 MHz
E = 1800 MHz and 1700MHz
F = 1900 MHz
G = 2100 MHz
H = 2500 MHz
I = 1700/2100 MHz

FTEA

Flexi Transport E1 Asymmetric sub-module, version A

FTEB

Transport E1 Asymmetric sub-module

FTFA

Flexi Transport Flexbus sub-module, version A

FTIA

Transport PDH symm. / Ethernet Hybrid sub-module

FTJA

Transport PDH Asymm. / Ethernet Hybrid sub-module

FTOA

Flexi Transport Optical STM-1/OC-3 sub-module, version


A

FTPA

Flexi Transport PDH E1/T1/JT1 symmetric sub-module,


version A

FTPB

Transport PDH E1/T1/JT1 symm sub-module

WMHC

UltraSite MHA WCDMA 2.1GHz (----? program design

WMPB

Pole Mounting Kit (Jade program design)

WPMB

Wideband Power Unit (Doris program design)

WPMC

Wideband Power Unit (Doris program design)

WPUB

Power Distribution Unit (Doris program design)

WPUC

Power Distribution Unit (Doris program design)

FREA

Flexi RF Module 1.8/1.7 Dual 50 W

FREB

Flexi RF Module 1.8/1.7 Single 50 W

FRIA

Flexi RF Module 1.7/2.1 Dual 50 W

FRIB

Flexi RF Module 1.7/2.1 Single 50 W

FRGC

Flexi RF Module 2100 Dual 50 W

FRGD

Flexi RF Module 2100 Single 50 W

FSKA

Flexi System Extension Kit

FSMA

Flexi System Module 1 FSP

FSMB

Flexi System Module 3 FSP

FTCA

Outdoor Cable RJ48C TQ-M/0 120ohm 5m


Outdoor Cable RJ48C 120 ohm 15m

CScode

Powersafe batt. 48V, 4x12V92F 92Ah/10h

FTCB

FTCC = next possible length

CD
code

Powersafe batt. 4x12V62F 48V-62Ah

FTCD

Outdoor Cable SMB-F/0 - BT43-F/0 75ohm 5m

FTCE

Outdoor Cable SMB-F/0 75 ohm 15m


FTCF = next possible length

FTCH

OD CableLC SM 1310 15 m
FTCG, FTCI = next possible lengths
FTCJ,FTCK, FTCL= next possible lengths

169

CT10772EN03GLA0

2014 Nokia Solutions and Networks. All rights reserved.

Potrebbero piacerti anche