Damaged section of
pipe is located and
uncovered.
Pipe coating is removed.
Damaged section of
pipe is cut and
removed.
QCS GripLock
GripLock
Connector B
deployed and stabbed
onto the pipe. Connector
not set until spool is
installed
QCS GripLock
GripLock Connector A deployed,
stabbed onto the pipe and set.
B
QCS FlangeMate
FlangeMate
Misalignment
Connector
Prefabricated spool
is lowered into
position.
QCS GripLock
GripLock Connector B
provides end gap adjustment.
QCS FlangeMate
FlangeMate Misalignment Connectors are aligned and bolted to
the flanged ends and the QCS GripLock
GripLock Connector B is locked in
place. An annulus test verifies the seal integrity of the QCS GripLock
GripLock
Connectors.