LEAD ACID & LITHIUM BATTERIES REQUIRE VENTING OVERBOARD (ACID TRAP FOR LEAD)
BATTERY CHARGING CIRCUIT HAS REVERSE CURRENT C.B TO DISCONNECT FROM MAIN BUS
IN EMERGENCY BATTERIES SUPPLY HOT BATTERY BUS ONLY FOR ESSENTIAL LOADS
NI-CAD & LITHIUM BATTERIES CHARGED FULLY BY CONSTANT CURRENT & HELD THERE BY CONSTANT VOLTAGE.
ALKALINE BATTERIES DECREASED INTERNAL RESISTANCE, LESS TEMP SENSITIVE, CHARGES QUICKER
LITHIUM BATTERY IS 30% LESS WEIGHT + SMALLER BUT DOSENT LIKE TO BE CHARGED IN LOW TEMP
BATTERIES MUST SUPPLY 30 MINS OF POWER AND HAVE TEMP SENSOR BY LEGISLATION
DC POWER GENERAGTION
CARBON PILE VOLTAGE SENSITIVE DEVICE, WHEN VOLTAGE INCREASE CARBON DISCS SEPARATE WHICH INCREASES RESISTANCE
AND VICE VERSA
VIBRATING TYPE- VOLTAGE SENSITIVE COIL (PARALLEL WITH GEN OUTPUT) BECOMES MORE MAGNETIC WHEN VOLTAGE INCREASES
WHICH OPENS THE CONTACT SO THE FIELD CURRENT PASSES THROUGH A DIFFERENT CIRCUIT WITH A RESISTOR IN IT
CARBON PILE/VIBRATING TYPE- PLACED IN SERIES WITH EXITOR FIELD TO REDUCE GEN OUTPUT VOLTAGE
CURRENT LIMITER SIMILAR TO VIBRATING CONTACT BUT COIL IS CURRENT SENSITIVE (IN SERIES WITH GEN OUTPUT)
TO STOP GENERATOR BEING BACK DRIVEN BY A BATTERY A REVERSE CURRENT CUT-OUT RELAY (R.C.C.R) IS USED WHICH
INCORPORATES BOTH A CURRENT COIL AND VOLTAGE COIL, WHEN FLOW IS REVERSED THE CURRENT COILS MAGNETISM OPPOSES
VOLTAGE COIL, IF GEN NOT OUTPUTTING ENOUGH THEN THERES NO MAGNETIC FIELD , THEREFORE OUPUT CONTACT OPENS.
TRIPLE UNIT REGULATOR INCLUDES VOLTAGE REGULATOR, CURRENT REGULATOR & R.C.C.R
PARALLELING COIL CONNECTS MULTIPLE GENS FIELD EXCITERS TO ALTER CURRENT TO BALANCE VOLTAGE OUTPUT , ONCE ALL
GEN OUTPUT VOLTAGE IS SIMILAR CONTACTS CLOSE
DIFFERENTIAL PROCTECTION- CONNECTS GENERATOR TO BUS BAR ONCE OUTPUT VOLTAGE IS 0.5 V ABOVE BUS BAR VOLTAGE,
THE C.B OPENS ON ENGINE SHUT DOWN ( PROTECTS AGAINST GEN BEING BACK DRIVEN)
GEN STARTED OFF-LOAD SO THAT THE FIELD VOLTAGE GETS A CHANCE TO BUILD UP
GALLEY SHED SWITCH ON OVERHEAD PANEL, ISOLATES GALLEY FROM BUS BAR WHEN THERES LOW POWER.
AC POWER GENERATION
REACTIVE (CONDUCTANCE/INDUCTANCE)- BACK EMF ON DOWN GOING WAVE -90 (LAG) CAPACITIVE -90 (LEAD)
SELF EXCITED GEN- AS SOON AS MAGNETS ROATED IN SEPARATE PERMANENT MAGNET GEN (PMG), THE EXCITER CIRCUIT IS
ENERGISED BY RECTIFIED DC OF THE PMG.
CSD CAN NOT BE RESET IN FLIGHT, RESEST ON GROUND WITH ENGINE STATIONARY VIA MANUAL RESET HANDLE
VARIABLE PITCH PUMP TYPE-CSD SPEED REGULATED BY SPEED GOVERNOR ADJUSTING SWASH PLATE(MOTOR WOBBLER) IN
ENGINE DRIVEN PUMP WHICH DRIVES THE MOTOR CONNECTED TO THE OUTPUT SHAFT
DIFFERENTIAL TYPE (GEAR)-CSD SPEED REGULATED BY DIFFERENTIAL GEARS WHICH SPEED UP OR SLOW DOWN CONTROLLED BY
MOTOR/PUMP ASSY ROTATING ONE WAY OR THE OTHER
CSD CLUTCH SOLENOID OPERATED TO ENGAGE ROTATING THREADED SHAFT IN STATIONARY THREADED PAWL TO WITHDRAW DOG
TOOTHED CLUTCH FROM ROTATING ENG INPUT SHAFT
SOLID STATE INVERTER - (SINUSOIDAL OSCILLATOR TO GIVE AC WAVE THEN TRANSFORMER USED TO GIVE DESIRED VOLTAGE)
VARIABLE SPEED CONSTANT FREQUENCY GEN (VSCF)- VARIABLE A.C IS RECTIFIED TO D.C AND THEN INVERTED TO CONSTANT
FREQUANCY A.C WAVEFORM.
ON PARALLEL SYSTEM THE BTB IS OPERATED BY GEN CONTROL UNIT (GCU) VIA BUS POWER CONTROL UNIT (BPCU)
DIFFERENTIAL PROTECTION - TO TRIP IF DIFFERENCE IN CURRENT BETWEEN LINE TO LINE, LINE TO EARTH AND LINE TO LINE TO
LINE.
OVER VOLTAGE PROTECTION CIRCUIT WILL TRIP QUICKER HIGHER THE VOLTAGE
IN THE CASE OF REAL LOAD SHARING CONTROL SIGNAL WILL CONTROL THE CSDU
IN THE CASE OF REACTIVE LOADS THE CONTROL SIGNAL WILL CONTROL FIELD EXCITATION
LIGHTS
CANDELA
HALGEN BULB - LOST ATOM RECOMBINE ON FILAMENT - DUE TO CHEMICAL REACTION FROM THE INTERNAL GAS(DO NOT TOUCH
WITH FINGERS-HOT SPOTS FROM GREASE)
FLUORESCENT -DUE TO THIER TOXIC CONTET THEY ME MUST BE DISPOSED OF IAW STRICT REGULATIONS
LUMINESCENT(GLOW IN THE DARK)-INTERNALLY COATED WITH PHOSPHOR/FILLED WITH RADIOACTIVE TITRUM GAS(SHOULD
BREAKAGE OCCUR EVACUATE WIT ALL DOORS OPEN TO ALLOW FULL VENTILATION)
CS-25(JAR 25)-REGULATIONS
TWO MAIN METHODS TO ENSURE CORRECT ANGLES ARE SET -PROTRACTOR/LIGHT ALIGNER
AUTO/ARMED MODE LIGHTS ARE OFF BUT COME ON IN THE EVENT OF POWER FAILURE
FLOOR PATH LIGHTING- EXIT IDENT LOCATED BETWEEN 18 INCHES & 4FT ABOVE CABIN FLOOR
ESCAPE PATH MARKINGS-DISTANCE BETWEEN MARKERS LESS THAN 20 IN/40 IN UNDER MEL CONDITION
25% RULE- NO MORE THAN 25% OF ESCAPE PATH MARKINGS U/S AFTER ANY SINGLE TRANSVERSE SEPARATION
STROBE INTENSITY LIGHTING- DANGER- ALLOW AT LEAST 10 MINS TO ALLOW CAPACITORS TO DISCHARGE BEFORE WORKING ON IT
NAVIGATION LIGHTS- PORT (LEFT) - RED 110 DEGREES / STARBOARD -GREEN 110 DEGREES/ TAIL-WHITE -140 DEGREES