DESIGN OF PRESTRESSED CIRCULAR WATER TANK:

DESIGN SPECIFICATIONS:

DIAMETER

: 100m

DEPTH

: 36m

CONCRETE GRADE

: M40

PERMISSIBLE COMP.STRESS UNDER TRANSFER

: 13N/mm2

MIN COMP STRESS UNDER WORKING PRESSURE

: 1N/mm2

LOSS IN PRESTRESS (assumed)

: 25%

: 0.75

LOSS RATIO (

@CIRCULAR WINDING
Reinforcement (assumed)
Dia of bars used

: 16mm

Circular Prestress (fs) : 1000N/mm2


@VERTICAL PRESTRESSING
Reinforcement (assumed)
Dia of bars used

: 20mm

Vertical Prestress (fs) : 1500N/mm2

Storage level

: full

Base condition

: fixed base condition

DESIGN:
STEP -1
Determination of ring tension and bending moment along the tank wall ( Nd & Mw) :

Mw = Coefficient x wH3
H2 / Dt
= 362/ 100 x 0.15
= 86.4
Assuming a max value of 56.0,
From IS3370 Part-4,
Coefficient = 0.0023
Mw = 0.0023 x 10 x 363
= 1073.688 kN m/m

RING TENSION
Nd = coefficient x W H R
H2 / Dt = 56.0
Coeff = 0.838
Nd = 0.838 x 10 x 36 x 50
= 15084kN/m