Sei sulla pagina 1di 2

CAT. NO.

D -F-13001

FIRE ALARM PANEL

FA P N 10 2 -R -10 L
FEATURES
Very small enclosure
10-zone capacity only
Conventional type
Switch-lock protection for operation
Easy-to-see front panel guidance
Alarm verification type
Name plate display for alarmed zones
Ni-Cd stand-by battery built in
Telephone handset built in for maintenance
Programmable function on front panel
Automatic self-checking
Various test facilities for maintenance
Surge arrestor built in for power lines
WALL MOUNTING TYPE
DESCRIPTION
The FAPN102-R-10L fire alarm panel was developed to
provide a cost- and space-saving conventional fire alarm
panel together with more user-oriented functions.
The size of the fire alarm panel is approximately 17%
smaller than that of our FAP129N series 10-zone fire alarm
panel.
The cabinet is made of ABS resin non-flammability to UL94V2.
The fire alarm panel equips with the function to lock the
operation of its front panel. That is useful to prevent the
unauthorized persons from operating the front panel.
<Alarm Inputs>
Conventional fire detectors and manual alarm boxes are
connected to alarm input circuits to give visual and audible
alarm at the panel and to actuate alarm bells. The
FAPN102-R-10L fire alarm panel has 10 alarm input circuits
(zones).
<Auxiliary input>
An auxiliary input signal can be connected to an auxiliary
input circuit to be displayed on the panel. It may be used for
a non-alarm input signal.
<Signal Outputs>
2 representative alarm signals are available.
10 voltage-free contacts are available for signal output when
an optional unit is used.
A group of output signal for an annunciator panel is
available when an optional unit is used.
<Alarm bell activation>
There are 2 modes to activate alarm bells. One is to actuate
all alarm bells at the same time, called general alarm. The
other is to actuate a group of alarm bells depending on the
location of a fire, called localized alarm.

One pair of terminals is available for the general alarm. The


programmable 10 voltage-free contacts are used for the
localized alarm when an optional unit is connected to the
panel.
<Automatic self-checking>
The following are automatically monitored at all time.
Detector circuits for continuity
Connection of the battery and fuse blown-out
Microcomputer chip and memory chips for abnormal
running
Main fuse for blown-out
Emergency voice alarm communication system circuit for
continuity and short
<Programming>
The following are programmable for setting and canceling
on the front panel.
Non used-alarm input circuits without putting dummy loads
Alarm verification function to alarm-input circuits
Interlocking an auxiliary input signal with an audible alarm
at the panel
Interlocking alarm input signals with representative alarm
signals
An audible alarm at the panel during main power off
Interlocking alarm input signals with 10 voltage-free contact
outputs.
<Fire protection-related device control>
The FAPN102-R-10L fire alarm panel is dedicated to the
fire alarm function. For controlling fire protection-related
devices such as smoke vents, fire extinguishing system etc.,
the FCS128N series fire alarm panel is available. Contact
our distributor in your region for the details of FCS128N
series.

HEAD OFFICE7-3, Kudan-Minami 4-chome, Chiyoda-ku, Tokyo 102-8277, Japan PHONE


813-3265-0231 FAX
813-3265-5348

FIRE ALARM PANEL FAPN102-R-10L

CAT. NO.

D -F-13001

TYPICAL WIRING DIAGRAM


(T)

(A)

End-of-line resistor 10K1/2W

Manual fire alarm box


Alarm signal lines (L)

Detector circuits : Max. 30 Smoke detectors per circuits.


No limit for contact type heat detectors.

Common line (C)


Fire alarm bell

NUMBER of WIRESBASIC

Fire alarm bell

nAlarm signal lines (L)


1Common line (C) for every
7 circuits
1Telephone line (T)
1Response line (A)
2Fire alarm bell lines (B)
2Location lamp lines (PL)

Location lamp
(B)
(PL)
n6 wires
Annunciator ()
220VAC
50/60Hz

Note : An optional unit is required for the fire alarm


panel when the annunciator is connected.

Resistance of detector circuits :


Less than 50/Loop
Terminals :
for use with 0.81.6mm wire

Fire alarm panel

SPECIFICATIONS
Model no.
TYPE
POWER SUPPLY
AUXILIARY POWER SUPPLY
CIRCUITS VOLTAGE
POWER CONSUMPTION
NOMINAL ALARM VERIFICATION TIME
MAXIMUM NUMBER OF APPARATUS
TO BE CONNECTED
AMBIENT TEMPERATURE
LOOP RESISTANCE OF ALARM INPUT CIRCUIT
END-OF-LINE RESISTOR
TERMINAL BLOCK
MATERIALSENCLOSURE
COLOR
DIMENSIONS
WEIGHT

FAPN102-R-10L
Wall-mounting type
220VAC 50/60Hz
Ni-cd battery24VDC, 0.45Ah
5, 24, 48VDC, 24VAC
Approx. 30VA for monitoring
Approx. 60VA for alarming
60sec.
Spot type smoke detectors : 30/zoneMax.100/panel
Projected beam type smoke detectors : 2/zone
Alarm bells : 2024VDC, 10mA/bell
Location Lamps : 730V, 2W/lamp2024VDC, 21mA/lamp
0 to 40
Less than 50/loop
10k, 1/2W
Insert type terminals suitable for solid conductors with a diameter of 0.8 to 1.6 mm
Use pin type solderless contacts for stranded conductors.
ABS resin with non-flammability to 94V2UL
Light gray : Nearly to Munsell no. 5.0Y 8.5/1.0
435mm
H
310mm
W
73mm
D
Approx. 4kg

ORDERING INFORMATION
10-zone fire alarm panel

FAPN102-R-10L

These

instructions do not purport to cover all the details or variations in the equipment described, nor provide for every possible contingency to be met in connection
with installation, operation and maintenance.
Specifications are subject to change without notice. Contact Nohmi before relying on above specifications.
Actual performance is based on proper application of the product by a qualified professional.
Should further information be desired or should particular problems arise, which are not covered sufficiently for the purchaser's purposes, the matter should be
referred to Nohmi or a distributer in your region.

OFFICE7-3, Kudan Minami 4-chome,


Chiyoda-ku, Tokyo 102-8277, Japan
PHONE
813-3265-0231
F A X
813-3265-5348
U R L http://www.nohmi.co.jp/eigo2/
HEAD

051020 D -F-13001YO1