Sei sulla pagina 1di 8

1336 - IC ACO Clara:1336 - IC ACO Clara

5.1.2009

11:39

Page 1

ACO Product Catalogue


ACO Clara
Waste water treatment plant
Sizes 3 120

1336 - IC ACO Clara:1336 - IC ACO Clara

5.1.2009

11:39

Page 2

ACO Clara

Characteristics and application

Treatment process

Benefits

ACO Clara sewage treatment plants


are designed for the complete biological
purification of domestic waste water:
single houses
residential areas
hotels
boarding houses
companies, etc.

Mechanical pre-treatment
Biological treatment by activated sludge
Final gravity sedimentation

ACO Clara sewage treatment


plants comply with all the requirementsof EN 12566-3, which is proven
by a
certificate.

BOD5 ...............................................6.7
COD ..............................................59.6
TSS ................................................6.1
N-NH4 ..............................................2.0

Perfect statics
Easy installation with no additional
concreting
Very stable and high treatment efficiency
during irregular hydraulic and biological
loads overload-resistant
First-class electrical components
Effective purification
Low maintenance
Low energy consumption
Odour-proof access cover with smart
construction
High volume of storage tank

Efficiency of purification
The following average values of effluents were
achieved during tests in an accredited laboratory
according to EN 12566-3:
mg/l
mg/l
mg/l
mg/l

blower
air
surplus sludge
raw sewage water
sludge return

Key:
1. Pre-treatment
2. Buffer area
3. Storage area
4. Activation tank
5. Final sedimentation tank

1336 - IC ACO Clara:1336 - IC ACO Clara

5.1.2009

11:40

Page 3

ACO Clara

Technology description
The ACO Clara sewage treatment plant consists
of a mechanical pre-treatment part and a
biological compartment.

The biological part of the ACO Clara consists of


an activation tank and a built-in final
sedimentation tank.

Surplus sludge is stored in the storage area,


which in fully loaded plants is capable of holding
about 100 - 150 days capacity.

The mechanical pre-treatment part is formed of


a sedimentation tank with a high buffer area
volume.

The activation tank is aerated by micro-bubble


aeration.

The pumping of sewage water and return and


surplus sludge is achieved using air lifts in the
ACO Clara. These air lifts need no maintenance
and are resistant to clogging. The hydraulic
capacity of the air lifts is continuously
adjustable, even at very low flow rates. This
helps to ensure a uniform purification process
and thus achieve stable purification efficiency.

The sewage water enters the ACO Clara unit via


the inlet pipe and flows into the buffer area of
the common buffer and storage tank. Settlable
solids fall to the bottom of the tank and floating
matter is caught by a scum board, thus
protecting the raw sewage air lift pump against
blockage.
Hydraulic peaks at the inlet of ACO Clara
sewage treatment plants are absorbed in the
buffer area. The pre-treated water is then
pumped at a uniform flow rate from the buffer
area into the biological part of the plant.
Hydraulic peak equalising considerably
increases the stable purification efficiency.

The water goes from the activation tank into


the final sedimentation tank, which enables
treated water to be separated gravitationally
from activated sludge. The treated water flows
out of the sewage treatment plant through the
outlet connection. The activated sludge falls to
the bottom of the final sedimentation tank, from
where it is pumped back as return sludge and
also partly into the storage area as surplus
sludge.

The only electric appliance of the ACO Clara is


a blower supplying air into the aeration
elements in the activation tank and into the air
lifts.

The final sedimentation tank is optionally


equipped with a skimmer for the automatic
collection and removal of floating sludge from
the water surface. This device can reduce
maintenance work during operation.

Air-lift Pump
Air Jet

Air Connection

Final Sedimentation Tank


3

Ventilation Pipe
Outlet Unit

Inlet Pipe
Activation Tank

Pre-treatment
Tank

Microbubble
Aeration Elements

1336 - IC ACO Clara:1336 - IC ACO Clara

5.1.2009

11:40

Page 4

ACO Clara

ACO Clara 3 29
Sizing, hydraulic and biological capacity
ACO Clara

3-6

5 - 10
8

7 - 14

11 - 22

15 - 29

12

18

24

Nominal hydraulic load [m /day]

0.75

1.20

1.80

2.70

3.60

Nominal biological load BOD5 [kg/day]

0.30

0.48

0.72

1.08

1.44

Nominal size in PE
3

Range of usage
3-6

5 - 10

7 - 14

11 - 22

15 - 29

Hydraulic load [m3/day]

0.45 - 0.90

0.75 - 1.50

1.05 - 2.10

1.65 - 3.30

2.25 - 4.35

Biological load BOD5 [kg/day]

0.18 - 0.36

0.30 - 0.60

0.42 - 0.84

0.66 - 1.32

0.90 - 1.74

Air supply pipe

Ven
t

ilat

H4

ion

DN

10

H2

H1

Number of persons

Outlet DN150

H3

Inlet DN150

Technical data
ACO Clara

3-6

5 - 10
8

Diameter D [mm]

1200

Lenght L [mm]

1470

7 - 14

11 - 22

15 - 29

1500

1800

2100

2350

1840

2150

2510

2870

Width W [mm]

1220

1540

1830

2140

2440

Height H [mm]

2180

2380

2480

2580

2640

Height of inlet pipe H1 [mm]

780

880

880

880

880

Height of outlet pipe H2 [mm]

880

980

980

980

980

Depth of water level H3 [mm]

1380

1490

1590

1690

1740

580

590

590

590

590

Height of ventilation pipe H4 [mm]


Weight [kg]
Power supply [V/Hz]
Power input [kW]
Article no.

215

350

475

630

865

230/50

230/50

230/50

230/50

230/50

0.06

0.11

0.13

0.22

0.24

411001

411002

411003

411004

411005

1336 - IC ACO Clara:1336 - IC ACO Clara

5.1.2009

11:40

Page 5

ACO Clara

ACO Clara 19 120


Sizing, hydraulic and biological capacity
ACO Clara
Nominal size in PE
3

19 - 38

24 - 48

30 - 60

38 - 76

48 - 96

60 - 120

32

40

50

63

80

100

Nominal hydraulic load [m /day]

4.8

6.0

7.5

9.45

12.0

15.0

Nominal biological load BOD5 [kg/day]

1.9

2.4

3.0

3.7

4.8

6.0

Range of usage
Number of persons
Hydraulic load [m3/day]
Biological load BOD5 [kg/day]

19 - 38

24 - 48

30 - 60

38 - 76

48 - 96

60 - 120

2.8 - 5.7

3.6 - 7.2

4.5 - 9.0

5.7 - 11.4

7.2 - 14.4

9.0 - 18.0

1.14 - 2.28

1.44 - 2.88

1.80 - 3.60

2.28 - 4.56

2.88 - 5.76

3.60 - 7.20

H2

H1
H4

Air supply pipe

Outlet
DN 200

Ventilation
DN100

H3

Inlet
DN200

LxW

Technical data
ACO Clara

19 - 38

24 - 48

30 - 60

38 - 76

48 - 96

60 - 120

Lenght L [mm]

3740

4140

4636

5240

5890

7290

Width W [mm]

1740

1890

2036

2190

2390

2390

Height H [mm]

2940

2940

2940

2940

2940

2940

880

880

880

880

880

880

Height of inlet pipe H1 [mm]


Height of outlet pipe H2 [mm]

980

980

980

980

980

980

Depth of water level H3 [mm]

1950

1950

1950

1950

1950

1950

Height of ventilation pipe H4 [mm]


Weight [kg]
Power supply [V/Hz]
Power input [kW]
Article no.

610

610

610

610

610

610

1165

1365

1580

1840

2150

2580

400/50

400/50

400/50

400/50

400/50

400/50

0.43

0.43

0.75

0.75

0.98

1.30

411006

411007

411008

411009

411010

411011

1336 - IC ACO Clara:1336 - IC ACO Clara

5.1.2009

11:40

Page 6

ACO Clara

Adapters of ACO Clara


Increasing the installation depth is possible
without any expensive construction work. The
main tanks of the AC Clara can be extended
with adapters, enabling the height of the main
tank to be increased quickly and easily. The
access cover(s) is (are) identical, either for use
with the main tank or with the adapter(s).

The adapter position is secured by screws. The


usage of two adapters with different heights
which can be used separately or together
makes possible height adjustment in a range of
multiples of 100 mm.

Type of adapters

L100

L250

L500

100

250

500

Height H [mm]
Weight [kg]

11

13

16

Article No.

411019

414020

411012

L250
L100

L500

1336 - IC ACO Clara:1336 - IC ACO Clara

5.1.2009

11:40

Page 7

ACO Clara

Additional equipment
Automatic removing of surplus sludge
To reduce the amount of maintenance work it
is possible to equip the ACO Clara with a control unit which enables surplus sludge to be
ACO Clara A
Article no.

removed automatically and floating sludge in


the final sedimentation tank to be removed
automatically.

3-6

5 - 10
8

7 - 14

11 - 22

15 - 29

19 - 38

24 - 48

30 - 60

38 - 76

48 - 96

60 - 120

411021

411022

411023

411024

411025

411026

411027

411028

411029

411030

411031

Box for outside installation of blower.


ACO Clara

AC 3 - 6

AC 11 - 22

AC 19 - 38

AC 30 - 60

AC 48 - 96

AC 5 - 10

AC 15 - 29

AC 24 - 48

AC 38 - 76

AC 60 - 120

AC 7 - 14
Weight [kg]

10

16

26

31

Article no.

411014

411015

411016

411017

411018

5.1.2009

11:40

Page 8

www.aco.com
The ACO Group a strong family you can trust.
All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO
products are made without guarantee since the conditions of use are beyond the control of the Company. It is the customers responsibility to ensure that each product is fit for its intended purpose and that the actual conditions of use are suitable. This brochure and any advice
is provided free of charge and accordingly on terms that no liability (including liability for negligence) will attach the Companyor its servants
or agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company will be
supplied solely upon its standard conditions of sale, copies of which are available on request. The Companys policy of continuous product
development and improvement renders specifications liable to modification. information provided in this brochure is therefore subject to
change without prior notification.
ACO Industries Tbor s.r.o.

1336/IC ACO Clara/En/12/08/JL

Subject to technical changes without notice

1336 - IC ACO Clara:1336 - IC ACO Clara

Potrebbero piacerti anche