1 A softstarter from ABB offers you several values and benefits. Whether you are a
consultant, OEM, panel builder or end-user, a softstarter will add to your business
value by securing motor reliability, improving installation efficiency and increasing
application productivity.
Secure motor
Reliability
ABB softstarters help increase your motors lifetime by protecting it from electrical
stress. Starting currents are easily optimized to your load, application and motor size.
Over ten motor protection features are included to keep your motor safe from different
load and network irregularities.
Improve installation
Efficiency
Reduce your installation time and panel size by having all features you need built into
your softstarter. Our softstarters are easy to install thanks to their compact design and
many built-in features. The built-in bypass saves energy and space while reducing heat
generation. A complete motor starting solution in one unit.
Increase application
Productivity
1/2
Installation time
reduced by
60%
50%
For more examples of how ABB's softstarters are helping the industry, visit www.abb.com/lowvoltage/launches/pstx
1/3
ABB softstarters
Improving industrial processes around the globe
1 A softstarter can do wonders with your operations. Packed with useful features, it
reduces the wear of your equipment, improve the reliability of your processes and
increase overall productivity.
Controlling pumps
Controlling fans
1/4
Controlling compressors
1/5
ABB softstarters
Why motor starting and stopping matters
1 There are some common issues associated with starting and stopping electrical
Direct-on-line
Star-delta
Softstarter
Torque
Motor current
Typical torque and current curves from starting a motor using DOL, star-delta and softstarter.
1/6
ABB softstarters
A solution for every need
1
ABBs softstarter offering consists of three ranges, covering every need. The
products help you secure motor reliability, improve installation efficiency and
increase application productivity.
Technical data:
Technical data:
Technical data:
3...105 A
30...370 A
208...600 V
208...600 V
100...240 V AC or 24
V AC/DC
100...250 V AC
30...1250 A
(inside delta: 2160 A)
208...690 V
100...250 V AC
Cu
rre
n
Cu t limi
t
rre
n
Ele t limi
t ra
ctr
oni
mp
cm
Du
al o
oto and d
Un verloa r ove ual c
der
urr
rloa
dp
e
Po load p rotec d pro nt lim
we
t
tec
it
r
i
o
o
tec
r fa
n
tion
Loc
ti
c
ked tor un on
der
rot
Cu
loa
o
rre
dp
nt/ r pro
t
r
Vol
Ph
tag ection otect
ase
ion
e
rev
i
m
Cu
bal
sto ersa
a
n
l
me
pro
ce
Mo
rd
efin tectio prote
tor
ctio
h
e
n
e
d
PT
pro
n
C/P ating
tec
T
t
10
i
Ov
o
n
0
erv
olta input
Ea
for
ge/
rth
mo
un
Bu fault p dervo tor p
ilt-i
rot
l
tag
n b rotec
e
Ins
tion e pro ction
ypa
ide
t
s
e
s
c
tion
Gra delta
con
ph
i
c
n
a
ect
De
tac l disp
i
lay on po
hab
Mo
a
ssi
l
e
tor
b
key nd k
eyp le
Pro runtim pad
ad
gra
ea
nd
Dia mma
sta
ble
gno
wa rt co
stic
Ov
un
rnin
s
erlo
g fu t
nct
Ov ad tim
erlo
ion
es
An ad tim to-trip
alo
e
-to
go
-co
Fie
utp
ol
ldb
ut
u
Eve s co
mm
nt
uni
Mu log
cat
ltip
ion
l
Ele e lan
g
ctr
uag
icit
es
ym
Tor
qu
e c eterin
Tor
ont
g
qu
e li rol
mit
Co
ate
dP
Lim
C
p m BA
Jog ode
w
Dy ith slo
nam
ws
pe
Sta ic br
ake ed fo
nd
rwa
s
t
i
Se
rd/
qu ll brak
rev
enc
e
ers
Ful
es
e
l vo
tar
t
l
t
age
Kic
ks
sta
t
rt
Ma art
nua
l pu
mp
cle
ani
ng
PSR
PSE
PSTX
17
o Opional
Not available
Softstarter Catalog | 1SFC132012C0201 - Rev. B |
1/7
ABB softstarters
A part of your motor starting solution
1 Motor starting requires several components to work perfectly together. ABB is a
one-stop shop for motor starting, offering all the necessary components and complete
motor starting solutions, proven together in numerous installations worldwide.
1
1
Softstarter
on
off
ATEX
Pilot devices
e.g. PLC
water level
sound
Emergency stop of motor
Terminal blocks
SNK series
6 PLC 800M
Automatic control
Remote communication
Line contactor AF
Isolation at stop
Isolation at faults
Emergency stop
Back-up DOL starter
1/9
ABB softstarters
Wall mounting instructions
Minimum distance to wall mm (in)
Softstarter, type
PSR
PSR3 ... PSR16
PSR25 ... PSR30
PSR37 ... PSR45
PSR60 ... PSR105
PSE
PSE18 ... PSE105
PSE142 ... PSE170
PSE210 ... PSE370
PSTX
PSTX30 ... PSTX105
PSTX142 ... PSTX170
PSTX210 ... PSTX370
PSTX470 ...PSTX570
PSTX720 ... PSTX840
PSTX1050 ... PSTX1250
0
0
0
0
0
0
0
0
25 (0.98)
25 (0.98)
25 (0.98)
25 (0.98)
N/A
N/A
N/A
N/A
100 (3.94)
100 (3.94)
100 (3.94)
10 (0.39)
10 (0.39)
10 (0.39)
20 (0.79)
20 (0.79)
20 (0.79)
N/A
N/A
N/A
100 (3.94)
100 (3.94)
100 (3.94)
150 (5.91)
150 (5.91)
150 (5.91)
10 (0.39)
10 (0.39)
10 (0.39)
15 (0.59)
15 (0.59)
15 (0.59)
20 (0.79)
20 (0.79)
20 (0.79)
20 (0.79)
20 (0.79)
20 (0.79)
35 (1.38)
35 (1.38)
35 (1.38)
35 (1.38)
35 (1.38)
35 (1.38)
303
O
O
303O 0
O 0
303
O
303O 0
1/10
Terminal kit
-
ABB softstarters
Certifications and approvals
The table below shows the certifications and approvals for ABBs softstarters.
Abbreviation
approved in
CE
EU
Approvals:
ship classification
societies
cULus
Canada
USA
CCC
China
EAC
Russia
ANCE
Mexico
C-tick
Australia
ABS
DNV GL
Lloyds
Register
CCS
PRS
Class
NK
Standard design approved, the products bear the certification mark when it is required.
No. 2004/108/EC
Electromagnetic compability
EN 60947-1
EN 60947-4-2
UL 508
CSA C22.2 No 14
1/11
2/2
Overview
2/4
Ordering details
2/5
Accessories
2/6
Technical data
2/7
Dimensions
2/8
Circuit diagrams
2/9
2/1
The PSR softstarter is the most compact of all the softstarter ranges which
allows for design of compact starting equipment. A PSR together with a
manual motor starter makes up a far more compact starting solution than a
star-delta starter, and with the built-in bypass, the energy losses inside the
softstarter are highly reduced.
Two-phase controlled
for monitoring
Secure motor
Reliability
Reduce the electrical stresses and keep the motor protected with the MMS
The PSR reduces the starting current for the motor. The possibility to connect it to
the manual motor starter makes it possible to build a compact and complete starting
solution with overload and short-circuit protection.
Improve installation
Saving time and money with built-in bypass and easy set-up
Increase application
Efficiency
Productivity
2/2
On the PSR, the bypass is built in and verified by ABB, saving you time during
installation and space in your panel. Set-up is done through three potentiometers
making it very fast and easy.
Soft start and stop with PSR will reduce mechanical wear and tear on the application
and increase the availability and uptime.
LED indicators
PSR has LED indicators for On/Ready and
Run/Top of ramp.
Settings
2 Step down
3 Uini
3 Uend
1 Start
2 Stop
2/3
Normal start
In-line connected
(400 V) kW
IEC, max. A
(440-480 V) hp
UL, max. FLA
PSR3
PSR6
PSR9
PSR12
PSR16 PSR25
PSR30
PSR37
PSR45
PSR60
PSR72
PSR85
PSR105
1.5
3.9
2
3.4
3
6.8
3
6.1
4
9
5
9
5.5
12
7.5
11
7.5
16
10
15.2
15
30
20
28
18.5
37
25
34
22
45
30
46.2
30
60
40
59.4
37
72
50
68
45
85
60
80
55
105
75
104
11
25
15
24.2
400 V, 40 C
Using manual motor
starters type 1 coordination will be achieved 1)
MS116
10 A
16 A
MS132
25 A
50 A
Overload protection is
used to protect the motor
from over heating 1)
100 A
60 A
125 A
90 A
AF12
AF16
200 A
125 A
TA75DU
AF26
AF30
AF38
AF52
250 A
OS250
110 A
TF42DU
MS495
OS125G
35 A
Line contactor
The line contactor is not
required for the softstarter
itself but often used to
AF9
open if OL trips 1)
2/4
63 A
OS32G
1)
32 A
MS450
AF65
150 A
200 A
TA110DU
AF80
AF96
AF116
Bow thruster
Centrifugal pump
Compressor
Conveyor belt (short)
Elevator
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
1SFC132072V0001
new.abb.com/low-voltage/products/softstarters
Rated operational voltage U e, 208...600 V AC
1SFC132024V0001
1SFC132028V0001
Type
Order code
Weight
pkg
(1 pce)
PSR3-600-70
PSR6-600-70
PSR9-600-70
PSR12-600-70
PSR16-600-70
PSR25-600-70
PSR30-600-70
PSR37-600-70
PSR45-600-70
PSR60-600-70
PSR72-600-70
PSR85-600-70
PSR105-600-70
1SFA896103R7000
1SFA896104R7000
1SFA896105R7000
1SFA896106R7000
1SFA896107R7000
1SFA896108R7000
1SFA896109R7000
1SFA896110R7000
1SFA896111R7000
1SFA896112R7000
1SFA896113R7000
1SFA896114R7000
1SFA896115R7000
kg
0.45
0.45
0.45
0.45
0.45
0.65
0.65
1.00
1.00
2.20
2.27
2.27
2.27
(lb)
(0.99)
(0.99)
(0.99)
(0.99)
(0.99)
(1.43)
(1.43)
(2.20)
(2.20)
(4.85)
(5.00)
(5.00)
(5.00)
PSR3-600-11
PSR6-600-11
PSR9-600-11
PSR12-600-11
PSR16-600-11
PSR25-600-11
PSR30-600-11
PSR37-600-11
PSR45-600-11
PSR60-600-11
PSR72-600-11
PSR85-600-11
PSR105-600-11
1SFA896103R1100
1SFA896104R1100
1SFA896105R1100
1SFA896106R1100
1SFA896107R1100
1SFA896108R1100
1SFA896109R1100
1SFA896110R1100
1SFA896111R1100
1SFA896112R1100
1SFA896113R1100
1SFA896114R1100
1SFA896115R1100
0.45
0.45
0.45
0.45
0.45
0.65
0.65
1.00
1.00
2.20
2.27
2.27
2.27
(0.99)
(0.99)
(0.99)
(0.99)
(0.99)
(1.43)
(1.43)
(2.20)
(2.20)
(4.85)
(5.00)
(5.00)
(5.00)
2/5
1SFC132169F0001
1SFC132224F0001
2
PSR16-MS116
1SFC132325F0002
1SFC132168F0001
PSLW
PS-FBPA
2/6
Pkg
qty
Weight
(1 pce)
kg
(lb)
Connection kit
PSR3 ... PSR16 with MS116 or MS132
PSR25 ... PSR30 with MS132-12 ... MS132-32
PSR37 ... PSR45 with MS450
PSR60 ... PSR105 with MS495
PSR16-MS116
PSR30-MS132
PSR45-MS450
PSR105-MS495
1SFA896211R1001
1SFA896212R1001
1SFA896213R1001
1SAM501903R1001
1
1
1
1
0.022
0.040
0.034
0.050
(0.049)
(0.088)
(0.075)
(0.110)
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
(lb)
Fan
PSR3 ... PSR45
PSR60 ... PSR105
PSR-FAN3-45A
PSR-FAN60-105A
1SFA896311R1001
1SFA896313R1001
1
1
0.010
0.013
(0.022)
(0.029)
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
(lb)
PSR-FAN60-105A
1SFC132012F0202
PSR-FAN3-45A
Order code
PSR105-MS495
1SFC132171F0001
PSR45-MS450
1SFC132208F0002
1SFC132170F0002
PSR30-MS132
Type
Terminal enlargements
PSR60 ... PSR105
Wire range mm2 1 x 10...50 mm2, 2 x 10...25 mm2
PSLW-72
1SFA899002R1072
0.150
(0.033)
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
(lb)
0.060
(0.132)
PS-FBPA
1SFA896312R1002
PSR3
PSR6
PSR9
PSR12 PSR16 PSR25 PSR30
600 V
208...600 V +10%/-15%, 50/60 Hz 5%
100...240 V AC, 50/60Hz 5% or 24 V AC/DC, +10%/-15%,
4 x Ie for 6 sec.
See table below for details
10 1)
20 1)
-25...+60 C (-13...+140 F)
-40...+70 C (-40...+158 F)
4000 m (13123 ft) 3)
IP10
12 VA
5W
0.7 W
10 VA
6.5 W
11.5 W
20.5 W
25 W
36 W
5.5 W
8.1 W
1 x 6...35 mm2
1 x 2.5...10 mm2
(14...8 AWG)
(10...2 AWG)
2 x 6...16 mm2
2 x 2.5...10 mm2
(14...8 AWG)
(10...6 AWG)
1 x 0.75...2.5 mm2 (19...14 AWG)
2 x 0.75...1.5 mm2 (19...16 AWG)
3A
0.5 A
3A
0.5 A
3A
0.5 A
Signal relays
for run signal
resistive load
AC-15 (contactor)
for top of ramp signal
resistive load
AC-15 (contactor)
LED
for On/Ready
for Run/Top of ramp
Settings
Ramp time during start
Ramp time during stop
Initial- and end voltage
PSR60
PSR72
PSR85
PSR105
IP20
IP20
2.9 W
PSR45
2)
control circuit
PSR37
3.6 W
5.2 W
7.2 W
6.6 W
Green
Green
1...20 sec.
0...20 sec.
40...70%
1)
Valid for 50% on time and 50% off time. If other data is required, contact your local ABB office.
Above 40 C (104 F) up to max. 60 C (140 F) reduce the rated current with 0.8% per C (0.44% per F).
3)
When used at high altitudes, above 1000 meters (3281 ft) up to 4000 meters (13123 ft), de-rate the rated current using the following formula.
[ % of Ie = 100 - x-1000 ] x = actual altitude of the softstarter in meter. [ % of Ie = 100 - y-3280 ] y = actual altitude of the softstarter in feet.
150
497
For de-rating of voltage, contact your local ABB office.
2)
40
PSR3
3A
6A
9A
12 A
16 A
PSR16
25 A
30 A
PSR25
PSR30
37 A
45 A
PSR37
PSR45
60 A
72 A
85 A
105 A
PSR60
PSR72 PSR85
PSR72 PSR85
PSR105
PSR85
PSR105
PSR105
-
50
60
80
PSR6
PSR9
PSR12
PSR16
PSR25
PSR30
PSR37
PSR9
PSR16 PSR25
PSR30
PSR37
PSR12
PSR25
PSR30
PSR37
PSR45
PSR45
PSR60
PSR45
PSR60
PSR60
PSR72
PSR72
PSR85
PSR105
-
100
PSR6
PSR60
PSR72
PSR85 PSR105
PSR105
-
40
50
60
80
PSR3
PSR6
PSR9
PSR12
PSR16
PSR25
PSR30
PSR37
PSR45
PSR60
PSR72
PSR85
PSR105
PSR16
PSR25
PSR30
PSR37
100
PSR9
PSR12
PSR25
PSR30
PSR37
PSR45
PSR45
PSR45
PSR60
PSR72
PSR85
PSR85
PSR105
PSR105
-
PSR60
PSR72
PSR105
-
Data based on an ambient temperature of 40 (104 F), starting current of 4 x Ie and ramp time 6 seconds.
For more optimized selection or to use PSR for heavy-duty starts, please use the softstarter selection tool.
2/7
mm, inches
PSR3 PSR16
PSR37 PSR45
1SFB536147G1204
1SFB536147G1204
PSR25 PSR30
2/8
mm, inches
With MMS and auxiliary contact With fuses, contactor and O.L.
1SFC132228F0001
1SFC132227F0001
1SFC132226F0001
1SFC132231F0001
1SFC132230F0001
1SFC132229F0001
With MMS and auxiliary contact With fuses, contactor and O.L.
1SFC132234F0001
1SFC132233F0001
1SFC132232F0001
With MMS and auxiliary contact With fuses, contactor and O.L.
2/9
3/0
3/2
Overview
3/4
Ordering details
3/6
Accessories
3/8
Technical data
3/9
Dimensions
3/12
Circuit diagrams
3/13
3/1
The PSE has been designed to meet the most common requirements from the
water segment and is specialized on pump operation. It combines the requested
protections with a very compact design and built-in bypass. Remote operation
with external keypad or over fieldbus is available as an option.
Two-phase controlled
as an option
Current limit
Kick-start
easy installation
Underload protection
Locked rotor protection
Secure motor
Reliability
Improve installation
Efficiency
Increase application
Productivity
3/2
Saving time and money with built-in bypass and compact design
On the PSE, the bypass is built in and verified by ABB, saving you time during
installation and space in your panel. The keypad is language neutral and illuminated
for easy set-up and operation in field. The compact design makes installation fast
and easy.
Screw mounting
PSE is fast easy to install by using screw mounting.
LED indicators
Green ready LED
Flashing - Suppy available
Steady - Main available
Green run LED
Flashing - Ramping up/down
Steady - TOR
Yellow protection LED
3/3
Normal start
In-line connected
(400 V) kW
IEC, max. A
(440-480 V) hp
UL, max. FLA
PSE18
PSE25
PSE30
PSE37
PSE45
PSE60
PSE72
PSE85
PSE105
7.5
18
10
18
11
25
15
25
15
30
20
28
18.5
37
25
34
22
45
30
42
30
60
40
60
37
72
50
68
45
85
60
80
55
106
75
104
400 V, 40 C
MCCB (35 kA)
Using MCCB only, type 1
coordination will be achieved 1)
1)
170M1563
170M1564
170M1566
T2S160
T3S250
170M1567
OS32GD
170M1568
170M1569
170M1571
OS63GD
170M1572
OS125GD
170M3819
OS250D
Line contactor
AF26
AF30
AF38
3/4
T3N250
T2N160
MCCB (50 kA)
AF52
AF65
AF80
AF96
AF116
Normal start
In-line connected
(400 V) kW
IEC, max. A
(440-480 V) hp
UL, max. FLA
PSE142
PSE170
PSE210
PSE250
PSE300
PSE370
75
143
100
130
90
171
125
169
110
210
150
192
132
250
200
248
160
300
250
302
200
370
300
361
400 V, 40 C
MCCB (35 kA)
Using MCCB only, type 1
coordination will be achieved 1)
T3N250
T4N320
T5N400
T5N630
T3S250
T4S320
T5S400
T5S630
170M5810
170M5812
170M5813
170M6812
OS400D
170M6813
OS630D
Line contactor
AF140
AF190
AF205
AF265
AF305
AF370
3/5
1SFC132001V0001
If more than 10 starts/h, select one size larger than the standard selection.
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
1SFC132002V0001
new.abb.com/low-voltage/products/softstarters
1SFC132003V0001
3/6
Type
Order code
PSE18-600-70
PSE25-600-70
PSE30-600-70
PSE37-600-70
PSE45-600-70
PSE60-600-70
PSE72-600-70
PSE85-600-70
PSE105-600-70
PSE142-600-70
PSE170-600-70
PSE210-600-70
PSE250-600-70
PSE300-600-70
PSE370-600-70
1SFA897101R7000
1SFA897102R7000
1SFA897103R7000
1SFA897104R7000
1SFA897105R7000
1SFA897106R7000
1SFA897107R7000
1SFA897108R7000
1SFA897109R7000
1SFA897110R7000
1SFA897111R7000
1SFA897112R7000
1SFA897113R7000
1SFA897114R7000
1SFA897115R7000
Weight
(1 pce)
kg
2.40
2.40
2.40
2.40
2.40
2.40
2.50
2.50
2.50
4.20
4.20
12.40
13.90
13.90
13.90
(lb)
(5.29)
(5.29)
(5.29)
(5.29)
(5.29)
(5.29)
(5.51)
(5.51)
(5.51)
(9.26)
(9.26)
(27.34)
(30.64)
(30.64)
(30.64)
Heavy duty
Description
1SFC132001V0001
If more than 10 starts/h, select one size larger than the standard selection.
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
new.abb.com/low-voltage/products/softstarters
1SFC132002V0001
1SFC132003V0001
Type
Order code
PSE18-600-70
PSE25-600-70
PSE30-600-70
PSE37-600-70
PSE45-600-70
PSE60-600-70
PSE72-600-70
PSE85-600-70
PSE105-600-70
PSE142-600-70
PSE170-600-70
PSE210-600-70
PSE250-600-70
PSE300-600-70
PSE370-600-70
1SFA897101R7000
1SFA897102R7000
1SFA897103R7000
1SFA897104R7000
1SFA897105R7000
1SFA897106R7000
1SFA897107R7000
1SFA897108R7000
1SFA897109R7000
1SFA897110R7000
1SFA897111R7000
1SFA897112R7000
1SFA897113R7000
1SFA897114R7000
1SFA897115R7000
Weight
(1 pce)
kg
2.40
2.40
2.40
2.40
2.40
2.40
2.50
2.50
2.50
4.20
4.20
12.40
13.90
13.90
13.90
(lb)
(5.29)
(5.29)
(5.29)
(5.29)
(5.29)
(5.29)
(5.51)
(5.51)
(5.51)
(9.26)
(9.26)
(27.34)
(30.64)
(30.64)
(30.64)
3/7
Wire range
SB8054C2
mm2
Cable connectors for Cu cables
PSE142 PSE170
6...120
PSE142 PSE170
2 x (50...120)
PSE210 PSE370
16...300
LZ...
Tightening Type
torque max.
Order code
Pkg
qty
Nm
14
16
25
1SDA066917R1
LZ185-2C/120 1SFN074709R1000
1SDA055016R1
Weight
(1 pce)
kg
(lb)
3
3
3
0.113
0.100
0.133
(0.249)
(0.220)
(0.293)
Pkg
qty
Weight
(1 pce)
3
1SFT98099-01C1
Wire range
Tightening Type
torque max.
mm2
Nm
1SFT98000_011C3
1SFT98099_125
1SFT98099_019C3
LT ... -AL
1SFC132328F0002
LT ... -AC
1SFC132355F0002
PSEEK
1SFC132168F0001
PSECA
PS-FBPA
3/8
(lb)
(0.172)
(0.293)
1SDA054988R1
1SDA055020R1
3
3
0.078
0.133
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
(lb)
bar
mm2
6.5
10.5
10.5
15 x 3
17.5 x 5
20 x 5
LW110
LW185
LW300
1SFN074307R1000
1SFN074707R1000
1SFN075107R1000
1
1
1
0.100
0.450
1.230
Req.
qty
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
(lb)
2
2
2
2
LT185-AC
LT185-AL
LT300-AC
LT300-AL
1SFN124701R1000
1SFN124703R1000
1SFN125101R1000
1SFN125103R1000
2
2
2
2
0.050
0.220
0.070
0.280
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
(lb)
PSEEK
1SFA897100R1001
0.198
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
(lb)
PSECA
1SFA897201R1001
0.130
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
(lb)
PS-FBPA
1SFA896312R1002
0.060
kg
Dimensions
hole
mm2
Terminal enlargements
PSE18 ... PSE105
PSE142 ... PSE170
PSE210 ... PSE370
LW...
31
43
Order code
Terminal shrouds
PSE142 ... PSE170, short for use with cable clamps
PSE142 ... PSE170, long for use with compression lugs
PSE210 ... PSE370, short for use with cable clamps
PSE210 ... PSE370, long for use with compression lugs
(0.220)
(0.992)
(2.712)
(0.110)
(0.485)
(0.154)
(0.617)
(0.437)
(0.287)
(0.132)
Time (s)
10 000
1000
100
Class 30
Class 20
Class 10
Class 10 A
Tripping curves for electronic overload protection (cold) for PSE and PSTX.
8
Current (x Ie)
1SFC132134F0201
10
3/9
Softstarter type
600 V
208...600 V +10%/-15%
Internal 24 V DC
Starting capacity at Ie
4 x Ie for 10 sec.
Main circuit
Supply and control circuit
Built-in bypass
Cooling system - fan cooled (thermostat controlled)
Display
Keypad
Setting current
Ramp time during start
Ramp time during stop
Initial/end voltage
Current limit
10 1)
10
-25+60 C (-13...+140 F) 2)
-40+70 C (-40...+158 F)
4000 m (13123 ft) 3)
IP00
IP20
Yes
Yes
4 7-segments and icons. Illuminated
2 selection keys and 2 navigation keys
Size dependent
1...30 sec
0...30 sec
30...70%
1.5...7 x Ie
Yes / No
Yes / No
Off, 30...100%
3
Run signal
TOR (bypass) signal
Event signal
250 V AC/24 V DC 4)
3A
1.5 A
4...20 mA
I Amp
Fixed at 1.2 x Ie
Number of inputs
On / Ready
Run / TOR
Protection
Fault
Electronic overload
Locked rotor protection
Underload protection
Connection for ABB FieldBusPlug
Display
Ambient temperature
During operation
During storage
Degree of protection
Maximum Altitude
Degree of protection
Main circuit
HMI for settings
Main settings
Signal relays
Analog output
Control circuit
Signal indication LED
Protections
Fieldbus connection
External keypad
Overload class
During operation
During storage
-25...+60 C (-13...+140 F)
-40...+70 C (-40...+158 F)
IP66
Valid for 50% on time and 50% off time. If other data is required, contact your local ABB office.
Above 40 C (104 F) up to max. 60 C (140 F) reduce the rated current with 0.6% per C (0,33% per F).
3)
When used at high altitudes, above 1000 meters (3281 ft) up to 4000 meters (13123 ft), de-rate the rated current using
the following formula. [ % of Ie = 100 - x - 1000 ] x = actual altitude of the softstarter in meters. [ % of Ie = 100 - y - 3280 ] y = actual altitude of the softstarter in feet.
480
150
For de-rating of voltage, contact your local ABB office.
4)
A common voltage needs to be used for all 3 signal relays.
1)
2)
3/10
PSE18 PSE105
PSE142 PSE170
PSE210 PSE370
17.5
20
E1859D
E1858D
8.5
Cu cable - Flexible
1 x mm2
Clamp type
Tightening torque
Cu cable - Flexible
2 x mm2
Clamp type
Tightening torque
Cu cable - Stranded
1 x mm2
Clamp type
Tightening torque
Cu cable - Stranded
2 x mm2
Clamp type
Tightening torque
Al cable - Stranded
1 x mm2
Clamp type
Tightening torque
Lugs
Width
Diameter>=
Tightening torque
Connection capacity acc to
UL / CSA 1 x AWG / kcmil
Clamp type
Tightening torque
Connection capacity acc to
UL / CSA 2 x AWG / kcmil
Clamp type
Tightening torque
Cu cable - Stranded 1 x mm2
Cu cable - Stranded 2 x mm2
Tightening torque
10.2
2.570 mm2
Included
8 Nm
2.570 mm2
Included
8 Nm
2.570 mm2
Included
8 Nm
2.570 mm2
Included
8 Nm
22 mm (0.866 in)
6.5 mm (0.256 in)
9 Nm (80 in lb)
6...2/0
6120 mm2
1SDA066917R1
14 Nm
50120 mm2
1SFN074709R1000
16 NM
6120 mm2
1SDA066917R1
14 Nm
50120 mm2
1SFN074709R1000
16 NM
95185 mm2
1SDA054988R1
31 Nm
24 mm (0.945 in)
8.5 mm (0.335 in)
18 Nm (159 in lb)
6...300 kcmil
16300 mm2
1SDA055016R1
25 Nm
16300 mm2
1SDA055016R1
25 Nm
185240
1SDA055020R1
43 Nm
30 mm (1.181 in)
10.2 mm (0.402 in)
28 Nm (248 in lb)
4...400 kcmil
Included
71 in lb
-
ATK185
300 in lb
-
ATK300
375 in lb
4...500 kcmil
ATK300/2
375 in lb
Current
range
Max
power loss
at rated Ie
Type
PSE18
PSE25
PSE30
PSE37
PSE45
PSE60
PSE72
PSE85
PSE105
PSE142
PSE170
PSE210
PSE250
PSE300
PSE370
A
5.4...18.0
7.5...25.0
9.0...30.0
11.1...37.0
13.5...45.0
18.0...60.0
21.6...72.0
25.5...85.0
31.8...106.0
42.9...143.0
51.3...171.0
63.0...210.0
75.0...250.0
90.6...302.0
111.0...370.0
W
0.2
0.4
0.5
0.8
1.2
2.2
3.1
4.3
6.6
12.1
17.6
8.8
12.5
18.0
27.4
1)
Type
170M1563
170M1564
170M1566
170M1567
170M1568
170M1569
170M1571
170M1572
170M3819
170M5809
170M5810
170M5812
170M5813
170M6812
170M6813
Size
000
000
000
000
000
000
000
000
1*
2
2
2
2
3
3
Power
requirements supply circuit
Holding (VA) /
Pull-in (VA)
16/19.9
16/19.9
16/19.9
16/19.9
16/19.9
16/19.9
16/19.9
16/19.9
16/19.9
16/31
16/31
30/700
30/700
30/700
30/700
3/11
40 mm
(1,57 in)
30 mm
(1,18 in)
1SFC132260F0001
35 mm
(1,38 in)
1SFC132266F0001
30 mm
(1,18 in)
3 mm (0,12 in)
1SFC132259F0001
37 mm
(1,46 in)
35 mm
(1,38 in)
43,75 mm 43,75 mm
(1,69 in) (1,69 in)
80 mm (3,15 in)
26 mm
(1,02 in)
27,4 mm
(1,06 in)
7 mm (0,27 in)
6 mm (0,24 in)
90 mm (3,54 in)
3/12
5 mm (0,20 in)
13 mm
(0,51 in)
88 mm (3,46 in)
90 mm (3,54 in)
3 mm (0,12 in)
5 mm (0,20 in)
PSE18 PSE105
L1
L2
L3
N
L N
L N
Start
Stop
Start
11
Start
Stop
1 2
10
Run TOR
2T1 4T2 6T3
11
12
13 14
1 2
Fault
NC
11
Start
Stop
KM1
10
Run TOR
NO
M
3
1SFC132274F0001, rev.2
Stop
11
12
13 14
Fault
NC
NO
M
3
1SFC132237F0001, rev.3
MCCB
3/13
4/0
4/2
Overview
4/4
Ordering details
4/6
Accessories
4/10
Technical data
4/11
Dimensions
4/16
Circuit diagrams
4/18
4/1
The PSTX combines many years of research and product development with
extensive knowledge of application specific requirements and needs.
It is our latest advancement in motor control and protection and
adds new functionality and increased reliability.
Three-phase controlled
100...250 V, 50/60 Hz
easy installation
(inside-delta: 2160 A)
control
protocols
corrosive atmosphere
Secure motor
Reliability
Improve installation
Efficiency
Increase application
Productivity
4/2
Easy to learn
Customizable
The PSTX has 17 pre-installed languages
along with options to customize your own
specific home screens (up to seven different).
You can use your customized home screens
to show status information important to your
process and hide information that is not.
Detachable
The PSTX comes with a detachable keypad
as standard. It can be placed on your panel
door, meaning you do not have to interrupt
your process in order to read status information or to change settings.
4/3
Normal start
In-Line connected
(400 V) kW
IEC, max. A
(440-480 V) hp
UL, max. FLA
PSTX30
PSTX37
PSTX45
PSTX60
PSTX72
PSTX85
PSTX105
PSTX142
PSTX170
15
30
20
28
18.5
37
25
34
22
45
30
42
30
60
40
60
37
72
50
68
45
85
60
80
55
106
75
104
75
143
100
130
90
171
125
169
400 V, 40 C
Using manual motor
starter or MCCB, type
1 coordination will be
achieved. 1)
XT2S160
170M1567
170M1568
OS32G
1)
170M1569
170M1571
OS63G
AF38
AF52
170M1572
OS125G
AF65
4/4
XT4S250
AF80
170M3819
170M5810
OS250
AF96
AF116
170M5812
OS400
AF140
AF190
Normal start
In-Line connected
(400 V) kW
IEC, max. A
(440-480 V) hp
UL, max. FLA
PSTX210
PSTX250
PSTX300
PSTX370
PSTX470
PSTX570
PSTX720
PSTX840
PSTX1050
PSTX1250
110
210
150
192
132
250
200
248
160
300
250
302
200
370
300
361
250
470
400
480
315
570
500
590
400
720
600
720
450
840
700
840
560
1050
900
1062
710
1250
1000
1250
400 V, 40 C
Using manual motor
starter or MCCB, type
1 coordination will be
achieved. 1)
Switch fuse
T4S320
T5S400
170M5812
170M5813
T7S800
170M6813
OS400
1)
170M6812
T5S630
170M6814
OS630
AF305
AF370
AF460
T7S1250
170M8554
170M6018
OS800
AF580
AF750
E2.2N 2000
170M6020
170M6021
AF1350
AF1650
4/5
1SFC132053V0001
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
new.abb.com/low-voltage/products/softstarters
Rated operational voltage Ue, 208...600 V
1SFC132058V0001
1SFC132098V0001
1SFC132103V0001
1SFC132101V0001
4/6
1SFA898103R7000
1SFA898104R7000
1SFA898105R7000
1SFA898106R7000
1SFA898107R7000
1SFA898108R7000
1SFA898109R7000
1SFA898110R7000
1SFA898111R7000
1SFA898112R7000
1SFA898113R7000
1SFA898114R7000
1SFA898115R7000
1SFA898116R7000
1SFA898117R7000
1SFA898118R7000
1SFA898119R7000
1SFA898120R7000
1SFA898121R7000
kg
6.10
6.10
6.10
6.10
6.10
6.10
6.10
9.60
9.60
12.70
12.70
12.70
12.70
25.00
25.00
46.20
46.20
64.20
64.70
(lb)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(21.16)
(21.16)
(27.99)
(27.99)
(27.99)
(27.99)
(55.12)
(55.12)
(101.85)
(101.85)
(141.54)
(142.64)
1SFA898203R7000
1SFA898204R7000
1SFA898205R7000
1SFA898206R7000
1SFA898207R7000
1SFA898208R7000
1SFA898209R7000
1SFA898210R7000
1SFA898211R7000
1SFA898212R7000
1SFA898213R7000
1SFA898214R7000
1SFA898215R7000
1SFA898216R7000
1SFA898217R7000
1SFA898218R7000
1SFA898219R7000
1SFA898220R7000
1SFA898221R7000
6.10
6.10
6.10
6.10
6.10
6.10
6.10
9.60
9.60
12.70
12.70
12.70
12.70
25.00
25.00
46.20
46.20
64.20
64.70
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(21.16)
(21.16)
(27.99)
(27.99)
(27.99)
(27.99)
(55.12)
(55.12)
(101.85)
(101.85)
(141.54)
(142.64)
Order code
Weight
(1 pce)
Heavy duty
Description
1SFC132038V0001
1SFC132053V0001
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
new.abb.com/low-voltage/products/softstarters
Rated operational voltage Ue, 208...600 V
1SFC132058V0001
1SFC132098V0001
1SFC132103V0001
1SFC132101V0001
1SFA898103R7000
1SFA898104R7000
1SFA898105R7000
1SFA898106R7000
1SFA898107R7000
1SFA898108R7000
1SFA898109R7000
1SFA898110R7000
1SFA898111R7000
1SFA898112R7000
1SFA898113R7000
1SFA898114R7000
1SFA898115R7000
1SFA898116R7000
1SFA898117R7000
1SFA898118R7000
1SFA898119R7000
1SFA898120R7000
1SFA898121R7000
kg
6.10
6.10
6.10
6.10
6.10
6.10
6.10
9.60
9.60
12.70
12.70
12.70
12.70
25.00
25.00
46.20
46.20
64.20
64.70
(lb)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(21.16)
(21.16)
(27.99)
(27.99)
(27.99)
(27.99)
(55.12)
(55.12)
(101.85)
(101.85)
(141.54)
(142.64)
1SFA898203R7000
1SFA898204R7000
1SFA898205R7000
1SFA898206R7000
1SFA898207R7000
1SFA898208R7000
1SFA898209R7000
1SFA898210R7000
1SFA898211R7000
1SFA898212R7000
1SFA898213R7000
1SFA898214R7000
1SFA898215R7000
1SFA898216R7000
1SFA898217R7000
1SFA898218R7000
1SFA898219R7000
1SFA898220R7000
1SFA898221R7000
6.10
6.10
6.10
6.10
6.10
6.10
6.10
9.60
9.60
12.70
12.70
12.70
12.70
25.00
25.00
46.20
46.20
64.20
64.70
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(21.16)
(21.16)
(27.99)
(27.99)
(27.99)
(27.99)
(55.12)
(55.12)
(101.85)
(101.85)
(141.54)
(142.64)
Order code
Weight
(1 pce)
4/7
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
1SFC132053V0001
new.abb.com/low-voltage/products/softstarters
1SFC132058V0001
1SFC132098V0001
1SFC132103V0001
1SFC132101V0001
4/8
1SFA898103R7000
1SFA898104R7000
1SFA898105R7000
1SFA898106R7000
1SFA898107R7000
1SFA898108R7000
1SFA898109R7000
1SFA898110R7000
1SFA898111R7000
1SFA898112R7000
1SFA898113R7000
1SFA898114R7000
1SFA898115R7000
1SFA898116R7000
1SFA898117R7000
1SFA898118R7000
1SFA898119R7000
1SFA898120R7000
1SFA898121R1000
kg
6.10
6.10
6.10
6.10
6.10
6.10
6.10
9.60
9.60
12.70
12.70
12.70
12.70
25.00
25.00
46.20
46.20
64.20
64.70
(lb)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(21.16)
(21.16)
(27.99)
(27.99)
(27.99)
(27.99)
(55.12)
(55.12)
(101.85)
(101.85)
(141.54)
(142.64)
1SFA898203R7000
1SFA898204R7000
1SFA898205R7000
1SFA898206R7000
1SFA898207R7000
1SFA898208R7000
1SFA898209R7000
1SFA898210R7000
1SFA898211R7000
1SFA898212R7000
1SFA898213R7000
1SFA898214R7000
1SFA898215R7000
1SFA898216R7000
1SFA898217R7000
1SFA898218R7000
1SFA898219R7000
1SFA898220R7000
1SFA898221R7000
6.10
6.10
6.10
6.10
6.10
6.10
6.10
9.60
9.60
12.70
12.70
12.70
12.70
25.00
25.00
46.20
46.20
64.20
64.70
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(21.16)
(21.16)
(27.99)
(27.99)
(27.99)
(27.99)
(55.12)
(55.12)
(101.85)
(101.85)
(141.54)
(142.64)
Order code
Weight
(1 pce)
Heavy duty
Description
1SFC132038V0001
Centrifugal fan
Conveyor belt (long)
Crusher
Mill
Mixer
Stirrer
1SFC132053V0001
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
new.abb.com/low-voltage/products/softstarters
1SFC132058V0001
1SFC132098V0001
1SFC132103V0001
1SFC132101V0001
1SFA898103R7000
1SFA898104R7000
1SFA898105R7000
1SFA898106R7000
1SFA898107R7000
1SFA898108R7000
1SFA898109R7000
1SFA898110R7000
1SFA898111R7000
1SFA898112R7000
1SFA898113R7000
1SFA898114R7000
1SFA898115R7000
1SFA898116R7000
1SFA898117R7000
1SFA898118R7000
1SFA898119R7000
1SFA898120R7000
1SFA898121R7000
kg
6.10
6.10
6.10
6.10
6.10
6.10
6.10
9.60
9.60
12.70
12.70
12.70
12.70
25.00
25.00
46.20
46.20
64.20
64.70
(lb)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(21.16)
(21.16)
(27.99)
(27.99)
(27.99)
(27.99)
(55.12)
(55.12)
(101.85)
(101.85)
(141.54)
(142.64)
1SFA898203R7000
1SFA898204R7000
1SFA898205R7000
1SFA898206R7000
1SFA898207R7000
1SFA898208R7000
1SFA898209R7000
1SFA898210R7000
1SFA898211R7000
1SFA898212R7000
1SFA898213R7000
1SFA898214R7000
1SFA898215R7000
1SFA898216R7000
1SFA898217R7000
1SFA898218R7000
1SFA898219R7000
1SFA898220R7000
1SFA898221R7000
6.10
6.10
6.10
6.10
6.10
6.10
6.10
9.60
9.60
12.70
12.70
12.70
12.70
25.00
25.00
46.20
46.20
64.20
64.70
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(13.45)
(21.16)
(21.16)
(27.99)
(27.99)
(27.99)
(27.99)
(55.12)
(55.12)
(101.85)
(101.85)
(141.54)
(142.64)
Order code
Weight
(1 pce)
4/9
Wire range
mm
SB8054C2
1SFT98099_095C2
4
LZ...
1SFT98000_012C3_
1SFT98000_011C3
1SFT98099_125
1SFT98099_019C3
LT ... -AC
LT ... -C
LT ... -AL
LT ... -L
8
16
25
22
35
45
1SDA066917R1
LZ185-2C/120 1SFN074709R1000
1SDA055016R1
OZXB4
1SCA022194R0890
1SDA013922R1
1SDA013956R1
3
3
3
3
3
3
0.113
0.300
0.133
0.570
0.570
0.570
(0.249)
(0.661)
(0.293)
(1.257)
(1.257)
(1.257)
31
43
31
1SDA054988R1
1SDA055020R1
1SDA023380R1
3
3
3
0.078
0.133
0.110
(0.172)
(0.293)
(0.243)
Type
Order code
Pkg Weight
qty (1 pce)
kg
(lb)
8.5
10.5
10.5
13
17.5 x 5
20 x 5
25 x 5
40 x 6
LX205
LX370
LX460
LX750
1SFN074810R1000
1SFN075410R1000
1SFN075710R1000
1SFN076110R1003
1
1
1
1
0.250
0.350
0.500
0.850
(5.551)
(0.772)
(1.102)
(1.874)
Terminal enlargements
PSTX30 PSTX105
6.5
PSTX142 ... PSTX170
10.5
PSTX210 ... PSTX370
10.5
PSTX470 ... PSTX570
10.5
PSTX720 ... PSTX840
13
15 x 3
17.5 x 5
20 x 5
25 x 5
40 x 6
LW110
LW205
LW370
LW460
LW750
1SFN074307R1000
1SFN074807R1000
1SFN075407R1000
1SFN075707R1000
1SFN076107R1000
1
1
1
1
1
0.100
0.250
0.450
0.730
1.230
(0.220)
(5.551)
(0.992)
(1.609)
(2.712)
Req.
qty
Type
Order code
Pkg Weight
qty (1 pce)
kg
(lb)
2
2
LT205-30C
LT205-30L
1SFN124801R1000
1SFN124803R1000
2
2
0,050
0.220
(0.110)
(0.485)
2
2
LT370-30C
LT370-30L
1SFN125401R1000
1SFN125403R1000
2
2
0.035
0.280
(0.077)
(0.617)
LT370-30D
1SFN125406R1000
0.150
(0.331)
2
2
LT460-AC
LT460-AL
1SFN125701R1000
1SFN125703R1000
2
2
0.100
0.800
(0.220)
(1.764)
LT750-AC
1SFN126101R1000
0.120
(0.265)
LT750-AL
1SFN126103R1000
0.825
(1.819)
Type
Order code
Pkg Weight
qty (1 pce)
kg
(lb)
PS-FBPA
1SFA896312R1002
0.060
(0.132)
DX111-FBP.0 1SAJ611000R0101
0.220
(0.485)
Terminal shrouds
PSTX142 ... PSTX170, short for use with cable clamps
PSTX142 ... PSTX170, long for use with
compression lugs
PSTX210 ... PSTX370, short for use with cable clamps
PSTX210 ... PSTX370, long for use with
compression lugs
PSTX210 ... PSTX370, long and deep for use with
extending cable clamps, ATK300/2 and OZXB4
PSTX470 ... PSTX570 , short for use with cable clamps
PSTX470 ... PSTX570, long for use with
compression lugs
PSTX720 ... PSTX840, short for use with cable clamps
PSTX720 ... PSTX840, long for use with
compression lugs
4/10
Pkg Weight
qty (1 pce)
kg
(lb)
bar
mm
LW...
Order code
Dimensions
hole
mm2
Terminal extensions
PSTX142 PSTX170
PSTX210 ... PSTX370
PSTX470 ... PSTX570
PSTX720 ... PSTX840
LX...
Tightening Type
torque max.
Nm
1000
100
Class 30
Class 20
Class 10
Class 10 A
Tripping curves for electronic overload protection (cold) for PSE and PSTX.
8
Current (x Ie)
1SFC132134F0201
10
4/11
Overload class
During operation
During storage
Main circuit
Supply and control circuit
Built-in bypass contactor
Cooling system - Fan cooled
Display
Languages
Signal relays
Keypad
Number of programmable signal relays
Main circuit
Analog output
Control circuit
K4
K5
K6
250 V AC/24 V DC
5A
Number of inputs
2 (start, stop)
3 (each input can be programmed to: None, Reset, Enable, Slow speed forward (Jog),
Slow speed reverse (Jog), Motor heating, Stand still brake, Start reverse, User defined
protection, Emergency mode (active high), Emergency mode (active low), Fieldbus
disable control, Start 1, Start 2, Start 3, Switch to remote control or Cancel brake)
Green
Green
Red
Yellow
Yes
LCD type, graphical
External keypad
Ready
Run
Fault
Protection
Detachable keypad
Display
Ambient temperature
During operation
During storage
Degree of protection
Soft start with voltage ramp
Soft stop with voltage ramp
Soft start with torque control
Soft stop with torque control
Kick start
Full voltage start
Sequence start
Current limit
Dual current limit
Current limit ramp
Torque limit
Pre-start function
Jog with slow speed, forward and reverse
Start reverse (external contactors)
Dynamic brake
Built-in Modbus RTU
Connection for Anybus
Connection for ABB FieldBusPlug
1.5 A
0...10 V, 0...10 mA, 0...20 mA, 4...20 mA
Motor current (A), Main voltage (V), Active power (kW), Active power (HP), Reactive
power (kVAr), Apparant power (kVArh), Active energy (kWh), Reactive energy (kVArh),
cos phi, Motor temperature (%), Thyristor temperature (%), Motor voltage (%), Main
frequency (Hz), PT100 temperature (centigrade), PTC resistance (Ohm)
-25...+60 C, (-13...+140 F)
-40...+70 C, (-40...+158 F)
IP66 (Type 1, 4X, 12)
Yes
Yes
Yes
Yes
Yes
Yes
Yes, 3 different sets of settings
Yes
Yes
Yes
Yes
Yes (Motor heating or Stand still brake)
Yes (3 speed levels)
Yes
Yes
Yes
Yes
Yes, with adapter
Valid for normal start (class 10) for 50% on time and 50% off time. If other data is required, contact your local ABB office.
Above 40 C (104 F) up to max. 60 C (140 F) reduce the rated current with 0,8% per C (0,44% per F).
When used at high alitudes, above 1000 meters (3281 ft) up to 4000 meters (13123 ft), de-rate the rated current using
the following formula.
[ % of Ie = 100- x-1000 ] x = actual altitude of the softstarter in meter, [% of Ie = 100 - x-3280 ] x = actual altitude of the softstarter in feet. For de-rating of voltage, contact your local ABB office.
497
150
1)
2)
3)
4/12
Warnings
PTC input
Other functions
For all functions and features see installation and commissioning manual, 1SFC132081M0201 available on new.abb.com/low-voltage/products/softstarters.
4/13
Current
range
Type
Type
Size
Power
requirements
supply circuit
Holding (VA) /
Pull-in (VA)
PSTX30
PSTX37
PSTX45
PSTX60
PSTX72
PSTX85
PSTX105
PSTX142
PSTX170
PSTX210
PSTX250
PSTX300
PSTX370
PSTX470
PSTX570
PSTX720
PSTX840
PSTX1050 3)
PSTX1250 3) 4)
9.0...30.0
11.1...37.0
13.5...45.0
18.0...60.0
21.6...72.0
22.5...85.0
31.8...106.0
42.9...143.0
51.3...171.0
63.0...210.0
75.0...250.0
90.0...300.0
111.0...370.0
141.0...470.0
171.0...570.0
216.0...720.0
252.0...840.0
315.0...1050.0
375.0...1250.0
0.8
1.2
1.8
3.2
4.7
6.5
10
18
26
48
68
97
148
99
146
78
106
165
234
100
125
160
160
250
315
400
500
630
630
700
800
900
900
1000
1250
1500
1800
2000
170M1567
170M1568
170M1569
170M1569
170M1571
170M1572
170M3819
170M5810
170M5812
170M5812
170M5813
170M6812
170M6813
170M6813
170M6814
170M8554
170M6018
170M6020
170M6021
000
000
000
000
000
000
1*
2
2
2
2
3
3
3
3
3
3
3
3
49/51
49/51
49/51
49/51
49/51
49/51
49/51
49/53
49/53
56/276
56/276
56/276
56/276
67/434
67/434
61/929
61/929
68/929
68/929
4/14
PSTX470
PSTX570
AF370
370
200
300
PSTX720
PSTX840
AF750
750
400
600
PSTX1050
PSTX1250
AF1250
-
PSTX30 ... PSTX105 PSTX142 ... PSTX170 PSTX210 ... PSTX370 PSTX470 ... PSTX570 PSTX720 ... PSTX1050
PSTX1250
50
1 x mm2
Clamp type
Tightening torque
Cu cable - flexible
2 x mm
Clamp type
Cu cable - Stranded
1 x mm
Clamp type
Included
1SDA066917R1
1SDA055016R1
8 Nm
14 Nm
25 Nm
6...35 mm
10...95 mm
LZ185-2C/120
1SFN074709R1000
50...95 mm
OZXB4 1)
1SCA022194R0890
16 Nm
22 Nm
6...150 mm
1SDA066917R1
70...185 mm
16...300 mm
1SDA055016R1
8 Nm
14 Nm
25 Nm
6...35 mm 2
50...120 mm 2
70...185 mm 2
120...240 mm 2
Included
LZ185 - 2C/120
1SFN074709R1000
OZXB4 1)
1SCA022194R0890
1SDA013922R1
8 Nm
16 Nm
22 Nm
35 Nm
70...185 mm 2
Clamp type
1SDA013956R1
Tightening torque
45 Nm
95...185 mm2
185...240 mm 2
Clamp type
1SDA0549881R1
1SDA055020R1
Tightening torque
31 Nm
43 Nm
120...240 mm2
Cu cable - Stranded
2 x mm2
Clamp type
Tightening torque
Cu cable - Stranded
3 x mm2
Al cable - Stranded
1 x mm2
Al cable - Stranded
13
16...240 mm2
Included
Tightening torque
6.5 12.5
10.5
6...120 mm 2
8 Nm
2
6.5
10...70 mm 2
Included
Tightening torque
22.5
E1860D
E1859D
E1858D
Cu cable - flexible
22.5
10.2
8.5
40
E1861D
20
17.5
27
25
2 x mm2
Clamp type
1SDA023380R1
Tightening torque
31 Nm
Width
24 mm (0.945 in)
32 mm (1.260 in)
47 mm (1.850 in)
50 mm (1.969 in)
50 mm (1.969 in)
Diameter >=
8 mm (0.355 in)
13 mm (0.519 in)
18 Nm (160 in lb)
28 Nm (248 in lb)
35 Nm (310 in lb)
45 Nm (398 in lb)
45 Nm (398 in lb)
6...2/0
6...300 kcmil
4...400 kcmil
Lugs
Tightening torque
Included
ATK185
ATK300
Tightening torque
71 in lb
300 in lb
375 in lb
4...500 kcmil
2/0...500 kcmil
2/0...500 kcmil
Clamp type
ATK300/2 2)
ATK580/2
ATK580/2
Tightening torque
375 in lb
375 in lb
375 in lb
2/0...500 kcmil
2/0...500 kcmil
Clamp type
ATK750/3
ATK750/3
Tightening torque
375 in lb
375 in lb
Cu cable - Stranded 2 x mm
Tightening torque
1)
2)
4/15
mm, inches
14 (2x)
113.8 110
(4.48) (4.43)
10.75
(0.42)
38.3
(1.51)
R4
(R0.16)
90.1
(3.55)
25
(0.98)
24 (0.94)
23
(0.91)
4/16
5 mm (0,2 in)
151 mm (5,9 in)
5 mm (0,2 in)
107,6 mm (4,2 in)
18 (2x)
178.8 mm (7 in)
3 mm (0,1 in)
13 mm (0,5 in) 6x
258 mm (10,2 in)
14 (2x)
14 (2x)
37.5
(1.48)
30 mm (1,2 in) 4x
75
(2.95)
178.8 mm (7 in)
5 mm (0,2 in)
18 (2x)
17,5 mm (0,7 in) 6x
3 mm (0,1 in)
13 mm (0,5 in) 6x
14 (2x)
mm, inches
6.5 (12x)
40 mm
(1.57 in)
72 mm
(2.83 in) 4x
7 mm (0.276 in) 4x
PSTX1050
(11.8 in)
7 mm (0.276 in) 4x
12.5 (6x)
8 (6x) mm
(0.3 in)
369 mm
(14.5 in)
8 mm (0.315 in)
63 mm (25 in)
40 (6x) mm
(1.57 in)
13 (4x)
361 mm (14.2 in)
25 mm (0.9 in) 6x
6 mm (0.2 in) 6x
6.5 (12x)
(5.2 in)
12.5 (6x)
7 mm (0.2 in) 4x
9 mm (0.3 in)
133.5 mm (2x)
301.5 mm
PSTX720
... PSTX840
13 (4x)
407 mm
(16 in)
7 mm (0.2 in) 4x
9 mm (0.3 in)
133.5 mm (2x)
(5.2 in)
12.5 (6x)
72 mm
(2.8 in)
6.5 (12x)
40 mm
(1.57 in)
301.5 mm
(11.8 in)
72 mm
(2.83 in) 4x
7 mm (0.276 in) 4x
7 mm (0.276 in) 4x
369 mm
(14.5 in)
8 mm (0.315 in)
63 mm (25 in)
25 mm (0.9 in) 6x
13 (4x)
6 mm (0.2 in) 6x
58.2 mm (2.3 in) 6x
6.5 (12x)
40 (6x) mm
(1.57 in)
12.5 (6x)
13 (4x)
407 mm
(16 in)
PSTX1250
133.5(2x) mm
(5.2 in)
13 (18x)
407 mm
(16 in)
4/17
8 (6x) mm
(0.3 in)
369 mm
(14.5 in)
50 (6x) mm
(1.9 in)
8 (6x) mm
(0.3 in)
369 mm
(14.5 in)
7 mm (0.276 in) 4x
13 (18x)
407 mm
(16 in)
7 mm (0.276 in) 4x
301.5 mm
(11.8 in)
72 mm (2.8 in) 4x
301.5 mm
(11.8 in)
72 mm (2.8 in) 4x
CAUTION
Terminal 22
is a function earth, it is not a
protective earth. It shall be connected to the
mounting plate.
5L3
3L2
1L1
Ct1
Ct2
22
In1
In0
Stop
14
Start
Stop
18
13
14
Start
K6
9
8
7
K5
6
5
4
K4
3
2
1
V2
HMI
V3
K2
V4
V5
3L2
13
12
11
10
5L3
19
18
20, 21
V1
6T3
13
Stop
Start
1L1
15
14
DGND
In2
4T2
14
16
2T1
13
GND
Internal
Bypass
Contactor
V6
L Bypass*
N 100-250V
L 50/60 Hz
Anybus
Fieldbus
23, 24
25, 26, 27
Modbus
Extension I/O
PTC
PT100
28
29
+24V
Analog out
Anybus
30
GND
6T3
20, 21
+24V
19
18
17
4T2
Stop Start
U V W
M
UL circuit diagram
INCOMING LINES
A
B
C
CHFU
AUTO
CHFU
H1
23
24
13
14
H2
H3
H4
CCT
CXFU
START
STOP
13
14
18
19
GND
20
21
K6
Relay
K5
Relay
17
DGND
In1
15 16
In2
Start
K4
Relay
14
In0
13
3
L
Stop
2
N
100-250V
50/60 Hz
1
L
Bypass*
GND 19
22
+24V 20, 21
DGND 18
STOP 13
21
10
11
12
22
L1
L2
L3
+24V
HAND
START 14
19
18
Ct3
2T1
21
20
Anybus
PTC
Modbus
PT100
Extension I/O
23
24
25, 26, 27
Fieldbus
+24V
28
Analog
GND
out
29
30
K1
T1
K2
T2
Anybus
MTR
MTR
K3
T3
O/I
F1.1
.2
.3
17 In2
16 In1
K4
K5
HMI
K6
Analog out
15 In0
14 Stop
13 Start
22
K7
Com 3
18 DGND
100-250V
50/60 Hz
19 GND
K7
11
3/L2
5/L3
K1
Com 2
Temp In
20
Com 1
+ 24V
Default: Event
21
K7
Default:Top of ramp
Default: Run
6/T3
10
1/L1
2/T1
Anybus
Soft starter
PSTX
4/T2
23 +(B)
24 -(A)
25 T1
PSTX
26 T2
27 T3
28 +24V
29 +
30 GND
12
K1
20 +24V
19 GND
18 DGND
W1
U1
3-wire control
V1
14 Stop
13 Start
Bjrn Johansson
Approved
RE
Lars Eriksson
150817
ABB
Application diagram
1SFB536005G5006
4/19
5/0
Fieldbus communication
Fieldbus communication
Introduction
5/2
5/3
5/4
5/6
5/1
Fieldbus communication
Introduction
PSR, PSE and PSTX softstarters can be connected to a fieldbus network for
monitoring and control. All major industrial fieldbus protocols are covered with
different accessories making the installation very flexible.
6
2
Integrated protocol
- Modbus-RTU
5/2
Softstarter PSR
Softstarter PSE
Softstarter PSTX
FieldBusPlug adapter
FieldBusPlug
Anybus
1SFC132120V0001
Fieldbus communication
Anybus ordering details
1SFC132121V0001
Profibus
Modbus-RTU
Type
Order code
Profibus
DeviceNet
Modbus-RTU
EtherNet/IP (1-port)
EtherNet/IP (2-port)
Modbus TCP (1-port)
Modbus TCP (2-port)
Profinet (2-port)
AB-PROFIBUS-1
AB-DEVICENET-1
AB-MODBUS-RTU-1
AB-ETHERNET-IP-1
AB-ETHERNET-IP-2
AB-MODBUS-TCP-1
AB-MODBUS-TCP-2
AB-PROFINET-IO-2
1SFA899300R1001
1SFA899300R1002
1SFA899300R1003
1SFA899300R1005
1SFA899300R1006
1SFA899300R1007
1SFA899300R1008
1SFA899300R1010
Pkg Weight
qty (1 pce)
kg
1
0.042
1
0.042
1
0.042
1
0.042
1
0.042
1
0.042
1
0.042
1
0.042
(lb)
(0.093)
(0.093)
(0.093)
(0.093)
(0.093)
(0.093)
(0.093)
(0.093)
DeviceNet
1SFC132118V0001
1SFC132119V0001
EtherNet/IP (1-port)
Modbus TCP (1-port)
EtherNet/IP (2-port)
Modbus TCP (2-port)
Profinet (2-port)
5/3
Fieldbus communication
FieldBusPlug ordering details
Black cable
DeviceNet FieldBusPlug
Designation
Cable length
Type
Order code
Pkg Weight
qty (1 pce)
kg
(lb)
DeviceNet-FBP
0.25 m
DNP21-FBP.025
1SAJ230000R1003
0.09
(0.20)
DeviceNet-FBP
0.50 m
DNP21-FBP.050
1SAJ230000R1005
0.10
(0.22)
DeviceNet-FBP
1.00 m
DNP21-FBP.100
1SAJ230000R1010
0.13
(0.29)
DeviceNet-FBP
5.00 m
DNP21-FBP.500
1SAJ230000R1050
0.36
(0.79)
Modbus-RTU FieldBusPlug
DNP21-FBP
MRP21-FBP
COP21-FBP
Designation
Cable length
Type
Order code
Pkg Weight
qty (1 pce)
kg
(lb)
MODBUS-RTU-FBP
MODBUS-RTU-FBP
MODBUS-RTU-FBP
MODBUS-RTU-FBP
0.25 m
0.50 m
1.00 m
5.00 m
MRP21-FBP.025
MRP21-FBP.050
MRP21-FBP.100
MRP21-FBP.500
1SAJ250000R0003
1SAJ250000R0005
1SAJ250000R0010
1SAJ250000R0050
1
1
1
1
Pkg Weight
qty (1 pce)
kg
1
0.20
1
0.01
4
0.01
0.09
0.10
0.13
0.36
(0.20)
(0.22)
(0.29)
(0.79)
Cable length
Type
Order code
1.5 m
MTQ22-FBP
CDP17-FBP.150
CDP11-FBP.4
1SAJ260000R0100
1SAJ929170R0015
1SAJ929100R0004
MTQ22-FBP
5/4
(lb)
(0.44)
(0.02)
(0.02)
Fieldbus communication
FieldBusPlug ordering details
Purple cable
Profibus DP FieldBusPlug
Ready-made Profibus DP fieldbus interface with various cable lengths.
Supports PROFIBUS DP V0 and V1
Applicable on all FBP motor starters and other devices
Degree of protection IP65, diagnostic LED
Designation
Cable length
Type
Order code
Profibus DP FBP
Profibus DP FBP
Profibus DP FBP
Profibus DP FBP
Profibus DP FBP
0.25 m
0.50 m
1.00 m
2.00 m
5.00 m
PDP22-FBP.025
PDP22-FBP.050
PDP22-FBP.100
PDP22-FBP.200
PDP22-FBP.500
1SAJ240100R1003
1SAJ240100R1005
1SAJ240100R1010
1SAJ240100R1020
1SAJ240100R1050
Pkg Weight
qty (1 pce)
kg
1
0.09
1
0.10
1
0.13
1
0.20
1
0.36
(lb)
(0.20)
(0.22)
(0.29)
(0.44)
(0.79)
PDP22-FBP
2CDC341048F0006
Note that the accessory PDQ22-FBP only works with the PSR and PSE softstarter.
Designation
Type
Order code
PDQ22-FBP
CDA11-FBP. 0
CDP11-FBP.0
1SAJ240200R0050
1SAJ929300R0001
1SAJ929100R0001
Pkg Weight
qty (1 pce)
kg
1
0.20
1
0.11
1
0.50
(lb)
(0.44)
(0.24)
(1.10)
PDQ22-FBP
Configuration software
2CDC341001S0011
This cable and software can be used for setup and comissioning of the softstarter as well as to
keep back-up of the parameter settings.
Designation
Type
Order code
UTF21-FBP
PBDTM-FBP
1SAJ929400R0002
1SAJ924012R0005
Pkg Weight
qty (1 pce)
kg
(lb)
1
0.01
(0.02)
1
-
5/5
Fieldbus communication
FieldBusPlug accessories ordering details
Black cable
DNF11-FBP.050
Designation
Cable length
Type
Order code
0.50 m
0.50 m
DNF11-FBP.050
DNM11-FBP.050
1SAJ923002R0005
1SAJ923003R0005
Pkg Weight
qty (1 pce)
kg
(lb)
1
0.04
(0.09)
1
0.04
(0.09)
Cable length
Type
Order code
Extension cable
Extension cable
Extension cable
Round cable
1.00 m
3.00 m
5.00 m
100.00 m
DNX11-FBP.100
DNX11-FBP.300
DNX11-FBP.500
DNC11-FBP.999
1SAJ923001R0010
1SAJ923001R0030
1SAJ923001R0050
1SAJ923004R0001
DNM11-FBP.050
DNX11-FDP
Pkg Weight
qty (1 pce)
kg
1
0.08
1
0.20
1
0.31
1
5.60
(lb)
(0.18)
(0.44)
(0.68)
(12.35)
Type
Order code
DNM11-FBP.0
DNF11-FBP.0
1SAJ923005R0001
1SAJ923006R0001
Pkg Weight
qty (1 pce)
kg
(lb)
5
0.15
(0.33)
5
0.15
(0.33)
DNM11-FBP.0
Designation
Type
Order code
DNR11-FBP.120
1SAJ923007R0001
DNR11-FBP.120
5/6
Pkg Weight
qty (1 pce)
kg
(lb)
1
0.02
(0.04)
Fieldbus communication
FieldBusPlug accessories ordering details
Purple cable
Ready-made bus cable with an M12 connector and an open cable end.
Application on bus junctions such as e.g. Profibus DB couplers or devices with an
integrated Profibus DB interface
ST05201lilac1
PDF11-FBP.50
Designation
Cable length
Type
Order code
Round cable
with female connector
Round cable
with male connector
0.50 m
PDF11-FBP.050
1SAJ924002R0005
Pkg Weight
qty (1 pce)
kg
(lb)
1
0.04
(0.09)
0.50 m
PDM11-FBP.050
1SAJ924003R0005
0.04
(0.09)
PDM11-FBP.50
2CDC341051F0003
PDX11-FBP
PDM11-FBP
2CDC341053F0003
2CDC341054F0003
PDF11-FBP
PDR11-FBP.150
2CDC341006F0004
PDV11-FBP,
PDV12-FBP
PDA11-FBP.050
Designation
Cable length
Type
Order code
Extension cable
Extension cable
Extension cable
Extension cable
Round cable
0.50 m
1.00 m
3.00 m
5.00 m
100.00 m
PDX11-FBP.050
PDX11-FBP.100
PDX11-FBP.300
PDX11-FBP.500
PDC11-FBP.999
1SAJ924001R0005
1SAJ924001R0010
1SAJ924001R0030
1SAJ924001R0050
1SAJ924004R1000
Pkg Weight
qty (1 pce)
kg
1
0.04
1
0.08
1
0.20
1
0.31
1
5.60
(lb)
(0.09)
(0.18)
(0.44)
(0.68)
(12.35)
Type
Order code
PDM11-FBP.0
PDF11-FBP.0
1SAJ924005R0001
1SAJ924006R0001
Pkg Weight
qty (1 pce)
kg
(lb)
5
0.03
(0.07)
5
0.03
(0.07)
Type
Order code
1SAJ924007R0001
1SAJ924008R0001
1SAJ924011R0001
1SAJ924009R0001
Pkg Weight
qty (1 pce)
kg
1
0.03
1
0.04
1
0.04
1
0.04
PDR11-FBP.150
PDV11-FBP.0
PDV12-FBP.0
PDA11-FBP.050
(lb)
(0.07)
(0.09)
(0.09)
(0.09)
PDA12-FBP.050
1SAJ924010R0001
(0.09)
Pkg Weight
qty (1 pce)
kg
1
0.01
1
0.01
1
0.20
1
0.20
0.04
Extension cable
2CDC341007F0004
PDA12-FBP.050
Designation
Cable length
Type
Order code
0.3 m
0.6 m
1.5 m
1.5 m
CDP15-FBP.030
CDP15-FBP.060
CDP15-FBP.150
CDP16-FBP.150
1SAJ929140R0003
1SAJ929140R0006
1SAJ929140R0015
1SAJ929150R0015
(lb)
(0.02)
(0.02)
(0.44)
(0.44)
5/7
ABB softstarters
Marketing material and tools
It is easy to access more information about ABBs softstarters online. On our
web page you will find tools for selection, coordination tables, CAD drawings and
different types of documentation.
www.abbcontrol.fr/softstarter
Coordination tables
Online tool for coordination with short circuit protection,
overload protection and line contactor.
applications.it.abb.com/SOC
SOC
Coord Selected O
ptimiz
in
ed
Coord ation
in
motor ation table
s
protec
for
tion
6/0
new.abb.com/low-voltage/products/softstarters
http://new.abb.com/low-voltage/launches/pstx
new.abb.com/low-voltage/
products/softstarters
6/1
ABB AB
Low Voltage Products
SE-721 61 VSTERS, Sweden
new.abb.com/low-voltage
new.abb.com/low-voltage/launches/pstx
Note
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
responsibility whatsoever for potential errors or
possible lack of information in this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein. Any
reproduction, disclosure to third parties or utilization of
its contents - in whole or in parts is forbidden without
prior written consent of ABB.
Copyright 2016 ABB
All rights reserved
Catalog 1SFC132012C0201 - Rev. B, November 2016. Prod. ABB AB, Low Voltage Products
Contact us