Electrak HD

Linear Actuator with Flexible Onboard Controls, Superior Performance and


Unmatched Environmental Protection

www.thomsonlinear.com

Electrak HD Superior Performance Linear Actuator


Higher Power, Longer Stroke, On-board Controls with optional J1939 CAN bus and
Unmatched Environmental Protection
The Electrak HD is a new electric linear actuator platform with onboard electronics
which can eliminate the need for standalone controls. Higher power opens a new,
wider range of hydraulic applications to electric conversion. And, it meets the most
extreme OEM component environmental acceptance tests, including IP69K.
Industry-Leading, Onboard Electronics
The new Electrak Modular Control System (EMCS)
is the foundation for the best onboard controls
currently available in electric linear actuators and
includes optional, built-in J1939 CAN bus support.
The feature-rich modular design for all control and
feedback options is simple to use and built within
one compact housing. It improves controllability,
saves space and reduces installation time and total
cost.

Superior Performance
Higher power and longer stroke lengths enable
Electrak HD to tackle applications outside the range
of other electric linear actuators.
Higher load ranges up to 10 kN (2250 lbs)
are ideal for hydraulic to electric conversion
applications.
Stroke lengths up to 1000 mm (39 in).
Efficient actuator design, including a high quality
ball screw, reduces current draw by up to 20%.

Built-in J1939 CAN bus option enhances


controllability, can eliminate individual controls
and simplifies OEM machine design.
Electronic trip point calibration ensures
consistent overload protection.
Constant monitoring of critical parameters
such as end-of-stroke, voltage, current and
temperature is standard on all HD actuators.
Built-in dynamic braking reduces coast at
the end of stroke, improving repeatability.
Optional low-level switching with automatic
sleep mode reduces footprint, lowers costs
and boosts circuit isolation.
Optional end-of-stroke indication output for
customer use, such as interlocks.

www.thomsonlinear.com/hd

Electrak HD

Unrivaled Environmental Protection


Electrak HD is tested to meet and exceed the
toughest OEM mechanical and electronic component
acceptance tests in the market today.
IP69K (static), IP67 (static) and IP66 (dynamic)
ratings prove Electrak HD can withstand the
harshest environments.
Capable of operating in a wide temperature range
from - 40 C to + 85 C (- 40 F to + 185 F).
Salt spray tested for 200 hours.
CE, RoHS and REACH (EU) certified.

www.thomsonlinear.com/hd

Additional Standard Features


Integrated manual override.
Standard anti-rotation actuation.
Integrated thermal overload protection.
Load lock in case of ball nut overload failure.
Flexible front and rear clevis options.

How Thomson Built a World-Class Linear Actuator


1. Start with the proven, rugged Electrak electric linear actuator.
2. Add state-of-the-art onboard controls, feedback, CAN bus J1939 and eliminate
the need for standalone controls.
3. Boost the power, increase stroke lengths, reduce current draw.
4. Design it all into a more compact envelope with the best
environmental protections on the market today.
INDUSTRY-LEADING ONBOARD CONTROLS
The new, Electrak Modular Control System is the foundation of the
best onboard controls available today for electric linear actuators and
includes optional, built-in J1939 CAN bus support.
1

Electrak Modular Control System (EMCS)


Electrak Monitoring Package (standard)
End-of-Stroke Indication Output Option

Analog Position Output Option


Digital Position Output Option
Low-Level Signal Motor Switching Option
J1939 CAN Bus Control Option
2

Built-in End-of-Stroke Limit Switches

Mounting Slots for External Limit Switches

15

10
12

www.thomsonlinear.com/hd

Electrak HD

SUPERIOR PERFORMANCE
Higher power and longer stroke lengths enable Electrak HD to tackle applications outside the
range of other electric linear actuators.
4

Modular Cabling

78

Large Variety of Adapters

55

Standard Anti-Rotation Feature

89

Integrated Manual Override

66

Static Load Holding Brake

10
9

High Efficiency Ball Screw Assembly

Robust Zinc Housing

11
13
9
14
7
8

1
2

6
5

UNRIVALED ENVIRONMENTAL PROTECTION


Electrak HD is tested to meet and exceed the toughest OEM mechanical and electronic
component acceptance tests in the market today.
10
11

IP67/IP69K Protection Class

14
13

Large Operating Temperature Range

12
11

Stainless Steel Extension Tube

14
15

Hard-coat Anodized Aluminum Cover Tube

13
12

Salt Spray Tested for 200 Hours

www.thomsonlinear.com/hd

Smart Onboard Electronics for Easier Control


Thomsons Electrak Modular Control System (EMCS) is built into every HD actuator
and serves as the foundation for the best onboard controls currently available on
the market including, optional, J1939 CAN bus.
Industry-leading Onboard Electronics
The Electrak Modular Control System is the
culmination of decades of global design and
application engineering in some of the toughest
environments.
Electronic Monitoring Package Standard on
all Electrak HD Actuators
Safety comes first. Each HD electric linear actuator
is equipped with the Electrak Monitoring Package
which will constantly monitor critical parameters
and take appropriate action as needed. Each unit
will reset automatically when conditions return to
normal allowing for operation to continue.

A Wide Range of Optional Control Features


Within the Same Compact Envelope
Optional control functions can eliminate the
need for external controls, saving design and
installation time, as well as space and installed
cost. A generous selection of control configurations
can tailor HD to fit a great breadth of heavy-duty
applications. The available control configurations
are described on the next page and more details,
including wiring diagrams for each option, begin on
page 22.

www.thomsonlinear.com/hd

Electrak HD

Electrak Monitoring Package Standard Features


Current Monitoring
A critical safety feature that shuts down the actuator on overload and
eliminates the need for the traditional noisy, mechanical clutch.

Load Trip Point Calibration


Each Electrak HD actuator is individually calibrated at assembly to
ensure a repeatable overload trip point.

Voltage and Temperature Monitoring


Continuous monitoring protects the actuator by preventing motion if
outside normal ranges.

Internal End-of-Stroke Limit Switches


Built in to each HD actuator, they ensure smooth, repeatable operation
and protect both connected equipment and the actuator.

Temperature Compensation
Boosts productivity by enabling normal operation at lower
temperatures without nuisance tripping.

End-of-Stroke Dynamic Braking


Enable quick end of stroke stops putting less stress on the internal
mechanical parts.

Optional Control Features


J1939 CAN Bus
Allows plug and play connectivity on your already established J1939
network.

Limit Switch Output


Confirms successful operation by indicating the actuator is fully
extended or retracted.

Mid Stroke Dynamic Braking


Standard with the low-level switching or the CAN bus options.
Reduces coast, improving repeatability.

Analog Position Output


A high quality potentiometer with essentially infinite resolution and low
noise provides a voltage signal for position and direction feedback.

Low-Level Switching
Improves safety and simplifies design by using low current (< 22 mA)
signals. Also saves energy with an auto sleep feature.

Digital Position Output


An encoder provides a single channel pulse train for position and
speed feedback, which can be used to allow synchronization via
customer control.

Control Option Combinations


Code

Control Combination Possibilities

Code

Control Combination Possibilities

EXX

Electrak Monitoring Package only

LXX

EXX + Low Level Signal Motor Switching

ELX

EXX + End of Stroke Indication Output

LLX

EXX + LXX + End of Stroke Indication Output

EXP

EXX + Analog Position Output

LXP

EXX + LXX + Analog Position Output

EXD

EXX + Digital Position Output

CNO

Can Bus J1939 Control + Open Loop Speed Control

ELP

ELX + Analog Position Output

ELD

ELX + Digital Position Output

www.thomsonlinear.com/hd

Bus Communication The Future of Actuator Control


Controlling an actuator over a network bus opens the door to breakthrough
opportunities in machine design. More control, monitoring and feedback options
can eliminate the need for separate controls. These options will also simplify
design, diagnostic feedback and installation while reducing installed costs.
The built-in CAN bus option makes it possible to
communicate with Electrak HD electric linear
actuators over a simple two-wire network.
CAN Bus in Practice
Electrak HD uses J1939 CAN bus, a well-known,
mature bus standard widely used in the construction
and agriculture industries. Up to 16 Electrak HD
actuators can be connected to the same controller
and to other CAN bus controls in the network.
Complex, real-time interactions between multiple
actuators and related systems are now much simpler
to monitor and control.
Application Examples
Check position of doors and hatches and take
action depending on the situation.
Monitor the temperature, overload condition or
voltage variations, then take action across the
network as needed. Examples: start ventilation,
reduce speed or stop an operation.
Confirm when position or other criteria are met.
Synchronize the motion of several actuators.

Benefits of CAN Bus Controls


Better controllability more complex and more
precisely controlled motion.
Improved safety feedback in real-time with all
operations verified.
Shorter design cycles and installation time
CAN bus means minimal wiring, no extra control
boxes and quick connection to existing networks.
Greater flexibility use the same actuator with
minor program edits for multiple applications
instead of designing for unique actuators and
controls for every type of application.
Reduced costs all the above will lead to
reduced design, component, installation,
operation and maintenance costs.

www.thomsonlinear.com/hd

Electrak HD

Control Architecture with and without CAN Bus


System Without CAN Bus
A power (1) is distributed to each device.
A main control (2) system communicates
separately with an individual control (3) box
connected to an actuator. Each instance may
require individual design, configuration, wiring
and installation.

Other equipment (4) that needs to be controlled


or integrated with the actuators requires
separate controls with more design and
configuration required.

1.

3.
3.
2.

3.

4.

System With CAN Bus


A control system and actuators with CAN bus
can communicate directly to each other. Adding
additional, separately configured actuators is fast
and easy. Only the power and a two-wire bus
cable are needed to extend the network.

Any other equipment with CAN bus can be


connected to the bus and communicate directly.
The result is a less complex system to design,
better performance and controllability and
reduced installation time and overall cost.

1.

4.

2.

www.thomsonlinear.com/hd

Electrak HD Smarter, Stronger, Longer


In addition to advanced control features, the Electrak HD offers 50% higher load
capacity, 60% longer stroke lengths than previous designs and is faster than the
competition at comparable loads. This new, extended envelope of operation also
opens a larger range of hydraulic applications to electric conversion.

Electrak HD offers smart design solutions, like builtin cable management, an integrated connector, and
a manual override feature on every actuator.

Building on the capabilities of the Electrak 10, the


workhorse of electric actuators for decades, the
Electrak HD offers onboard controls, higher load
10

capacity (up to 10 kN, 2250 lbs.), longer strokes (up


to 1 meter, 39 in.) and higher speeds.
www.thomsonlinear.com/hd

Electrak HD

Ready to Work in Extreme Environments


The Electrak HD is well-suited for heavy-duty, industrial, applications including
conversion of hydraulic to electric actuation. It shows its mettle when used
under the harshest conditions. Each HD actuator is designed to meet and
exceed the toughest OEM mechanical and electrical components tests,
including IP69K.
Rated IP66 (dynamic), IP67 (static), and IP69K (static)

Withstands dirt, water,


fertilizers, acids and oils

www.thomsonlinear.com/hd

Up to +85 C (+185 F)

Down to - 40 C (- 40 F)

11

Accelerated Trend Toward Electric Conversions


Once dominated by manual, pneumatic, and hydraulic systems, mobile on and off
highway equipment is increasingly equipped with electric actuators to automate
many tasks. Electric linear actuators are easier to integrate with modern computerbased control systems and are precisely controlled. They consume a smaller
footprint and are cleaner than both pneumatic and hydraulic systems
Converting to Electric Immediately Eliminates:
The cost and bulk of pumps, valves and hoses.
Environmentally hazardous oil and leaks.
Costly hydraulic reliability issues and
contamination.
The high energy consumption of pneumatic and
hydraulic systems.
Nuisance start-up failures in cold temperatures.

See the full conversion story at:

www.thomsonlinear.com/hd
12

www.thomsonlinear.com/hd

Electrak HD

Easier Installation, Superior Control and Less Complexity


Simpler, Smaller and Faster to Install
Electric actuation requires fewer components
than hydraulic or pneumatic systems for faster
and easier installation.
Component costs are less than in comparable
hydraulic or pneumatic systems.
A smaller footprint simplifies and speeds design.

Easier Control, Better Accuracy


All electric components mean easier integration,
fewer control components and less complexity.
Electric actuators react quicker and more
predictably. Will not drift when power is off.
Lower Energy Costs
Electric motors are intrinsically more efficient
than pneumatic or hydraulic motors.
No need to up-size the existing system to
account for potential parasitic power draw.
No power required to hold load reducing power
consumption.
Less Maintenance
No hydraulic pumps, valves, or hoses means
reduced downtime with fewer parts to service
and replace.
Self-contained units with smart, onboard
electronics require zero maintenance, adding
design flexibility in component placement.
Electric actuation eliminates the cost and hassle
associated with fluid maintenance.
Cleaner, Quieter, Healthier Environment
No pumps, fluids, chemicals or solvents
translates into a cleaner and quieter workspace.
A compact design requires fewer materials to be
used in production.
Regional manufacturing and distribution plants
minimize freight and reduce the carbon footprint.

www.thomsonlinear.com/hd

13

Improving Machine Design with Electric Actuation


These applications illustrate how the Electrak HD can deliver huge benefits over
pneumatic and hydraulic mechanisms, including reduced design, installation and
operation costs while improving controllability, safety and productivity.
Single-User Maintenance and Repair

Quick-Attach

Electric linear actuators enable a single maintenance


or repair technician to access the engine compartment
quickly and safely.

Quick-attach actuators allow the operator to change


implements on the loader or skid steer without
leaving the seat for improved productivity and
safety.

Utility Vehicles

Roadwork and Construction Site Equipment

Garden, construction and service vehicles require


rugged, efficiently controlled performance. The
environmental protection (IP69K), high load
capabilities, and J1939 CAN bus communication
provide that performance.

Long stroke, protection against harsh environments


and high load rating (including high shock loading for
wind shear) make the Electrak HD a great fit for this
roadside construction sign.

14

www.thomsonlinear.com/hd

Electrak HD

Railroad Equipment

Logistic Systems

Railroad equipment experiences the toughest


conditions. Whether it is to open and close a
gravity bin or to control a pantograph, the Electrak
HD actuator will perform effectively despite harsh
weather, heavy vibrations and high pressure washing.

The Electrak HD, with its built-in J1939 CAN bus


capabilities, makes it easy to build intelligent
logistic systems such as the material handling train
shown here.

Emergency and Rescue Vehicles

Switch Gears

The deployment of lighting on emergency vehicles


demands the most reliable operation. Electrak HD is
easily controlled, has a built-in manual override and
operates reliably in all weather to help emergency
responders do their jobs safely.

Electrical switch gears are often placed in remote


locations. It is critical that power switching is
executed and confirmed without fail. Electrak HD
is ideal for this task in arctic to high-temperature
conditions.

www.thomsonlinear.com/hd

15

Electrak HD Technical Features


General Specifications
Parameter

Electrak HD

Screw type

ball

Nut type

load lock ball nut

Manual override

yes

Anti-rotation

yes

Dynamic braking

yes (1)

Static load holding brake

yes

End-of-stroke protection

internal end-of-stroke limit switches

Overload protection

yes

Temperature monitoring

yes

Temperature compensation

yes

Voltage monitoring

yes

Electrical connections

cable(s) with flying leads

(2)

Certificates

The Electrak HD is a New Electric Linear


Actuator Platform
Onboard electronics eliminate the need for
standalone controls. Higher power opens a new,
wider range of hydraulic applications to electric
conversion. And, the Thomson Electrak HD meets
the most extreme OEM component environmental
acceptance tests, including IP69K.

CE

(1) Dynamic braking is included at the ends of stroke for all Electrak HD actuators. Dynamic
braking offered throughout the entire stroke length only on low-level switching and J1939
options.
(2) There are one or two cables depending on the control option used. The cable(s)
enters the actuator via a connector. The replacement of an actuator can be completed by
unplugging the old actuator and plugging in the new one.

Optional Features
Parameter
Mechanical options

Electrak HD
Variety of front and rear adapters
Alternative adapter orientation

Control options
(see page 22)

End-of-stroke output
Analog position feedback
Digital position feedback
Low-level signal motor switching
CAN bus J1939

Accessories
Parameter

16

Electrak HD

Mechanical

Rod end front adapter

Electrical

External slot mounted limit switches

www.thomsonlinear.com/hd

Electrak HD

Electrak HD Technical Specifications


Mechanical Specifications

Electrical Specifications

Parameter

Electrak HD

Max. static load (1)

[kN (lbs)]

Max. dynamic load (Fx)


HDxx-B017
HDxx-B026
HDxx-B045
HDxx-B068
HDxx-B100

[kN (lbs)]

Parameter

18 (4050)
1.7 (382)
2.6 (585)
4.5 (1012)
6.8 (1529)
10 (2248)

Electrak HD

Available input voltages

[Vdc]

Input voltage tolerance


HD12 (12 Vdc input voltage)
HD24 (24 Vdc input voltage)

[Vdc]

12, 24
9 - 16
18 - 32

Min. ordering stroke (S) length

[mm]

100

Current draw @ no load/max. load


HD12-B017
HD24-B017
HD12-B026
HD24-B026
HD12-B045
HD24-B045
HD12-B068
HD24-B068
HD12-B100
HD24-B100

Max. ordering stroke (S) length

[mm]

1000

Motor leads cross section

[mm2 (AWG)]

2 (14)

Ordering stroke length increments

[mm]

50

Signal leads cross section

[mm (AWG)]

0.5 (20)

Speed @ no load/max. load


HDxx-B017
HDxx-B026
HDxx-B045
HDxx-B068
HDxx-B100

[mm/s (in/s)]
71/58 (2.8/2.28)
40/32 (1.6/1.3)
24/19 (0.94/0.75)
18/14 (0.71/0.55)
11/9 (0.43/0.35)

Operating temperature limits

[C (F)] - 40 85 (- 40 185)

Full load duty cycle @ 25 C (77 F)

[%]

[A]

Standard cable lengths (Ca1)

[m (in)]

25 (2)

End play, maximum

[mm (in)]

1.2 (0.047)

Restraining torque

[Nm (lbs)]

Protection class - static

IP67 / IP69K

Protection class - dynamic

3/18
1.5/9
3/18
1.5/9
3/18
1.5/9
3/20
1.5/10
3/18
1.5/9

0.3, 1.5, 5
(11.8, 59, 197)

Cable diameter (Ca2)

[mm (in)]

7.5 (.295)

Flying lead length (Ca3)

[mm (in)]

76.2 (3)

Stripped lead length (Ca4)

[mm (in)]

6.35 (0.25)

IP66

Salt spray resistance

[h]

200

Max. static load at fully retracted stroke.


2
For a HDxx-B1000 actuator, unidirectional load, the duty cycle is 15%.
1

The drawing shows the cables exiting the cable slots at the end of the actuator housing
which is the shipping position. The user can adjust the exit point to be anywhere between
the connector (1) in the front of the housing and the end of the cable slots.

Actuator Weight [kg]


Maximum Dynamic
Load (Fx) [kN (lbs)]

Ordering Stroke (S) [mm]


100

150

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

950 1000

1.7 (382)

6,5

6,7

7,0

7,2

7,5

7,7

8,0

8,2

8,5

8,7

9,0

9,2

9,5

9,7

10,0 10,2 10,5 10,7 11,0

2.6 (585)

6.5

6.7

7.0

7.2

7.5

7.7

8.0

8.2

8.5

8.7

9.0

9.2

9.5

9.7

10.0 10.2 11.6 11.9 12.2

4.5 (1012)

6.5

6.7

7.0

7.2

7.5

7.7

8.0

8.2

8.5

8.7

9.0

9.2

10.4 10.7 11.0 11.3 11.6 11.9 12.2

6.8 (1592)

6.5

6.7

7.0

7.2

7.5

7.7

8.0

8.2

8.5

9.5

9.8

10.1 10.4 10.7 11.0 11.3 11.6 11.9 12.2

10 (2248)

6.7

7.0

7.2

7.5

7.7

8.0

8.2

9.1

9.4

9.7

10.0 10.3 10.6 10.9 11.2 11.5 11.8 12.1 12.4

Conversion Factors: Millimeter to inch: 1 mm = 0.03937 in, kilogram to pound: 1 kg = 2.204623 lbs

www.thomsonlinear.com/hd

17

How to Order the Electrak HD


This ordering key provides a quick overview of the product versions available. It is important
to consider many application details when selecting a product, including the loads, speeds
and control options required, as well as the product environment and necessary accessories.
To explore additional technical resources and options, contact Thomson customer support at
www.thomsonlinear.com/hd.
Ordering Key
1

HD12

B026-

0300

LXX

1. Model and input voltage


HD12 = Electrak HD, 12 Vdc
HD24 = Electrak HD, 24 Vdc
2. Screw type, dynamic load capacity
B017- = ball screw, 1.7 kN (382 lbs)
B026- = ball screw, 2.6 kN (585 lbs)
B045- = ball screw, 4.5 kN (1012 lbs)
B068- = ball screw, 6.8 kN (1529 lbs)
B100- = ball screw, 10 kN (2248 lbs)
3. Ordering stroke length (1)
0100 = 100 mm
0150 = 150 mm
0200 = 200 mm
0250 = 250 mm
0300 = 300 mm
0350 = 350 mm
0400 = 400 mm
0450 = 450 mm
0500 = 500 mm
0550 = 550 mm
0600 = 600 mm
0650 = 650 mm
0700 = 700 mm
0750 = 750 mm
0800 = 800 mm
0850 = 850 mm
0900 = 900 mm
0950 = 950 mm
1000 = 1000 mm

4. Electrak Modular Control System options


EXX = Electronic Monitoring Package only
ELX = EXX + end-of-stroke indication output
EXP = EXX + analog (potentiometer) position output
EXD = EXX + digital position output
ELP = ELX + analog (potentiometer) position output
ELD = ELX + digital position output
LXX = EXX + low-level signal motor switching
LLX = EXX + LXX + end-of-stroke indication output
LXP = EXX + LXX +analog (potentiometer) position output
CNO = Can bus J1939 + open loop speed control
5. Harness option
1 = 0.3 m long cables with flying leads
2 = 1.5 m long cables with flying leads
3 = 5.0 m long cables with flying leads
6. Rear adapter option
M = cross hole for 12 mm pin
E = cross hole for inch pin
N = forked cross hole for 12 mm pin
F = forked cross hole for inch pin
7. Front adapter option
M = cross hole for 12 mm pin
E = cross hole for inch pin
N = forked cross hole for 12 mm pin
F = forked cross hole for inch pin
P = metric female thread
G = inch female thread
8. Adapter orientation
S = standard
M = 90 turned
(1) Other stroke lengths available on request, please contact customer support.

18

www.thomsonlinear.com/hd

Electrak HD

Performance Diagrams

Speed [mm/s (in/s)]

Load vs. Speed

Load [N (lbs)]

Current for 24 Vdc Actuators [A]

Current for 12 Vdc Actuators [A]

Load vs. Current

Load [N (lbs)]
Screw type and Dynamic Load Capacity
ball screw, 1.7 kN (382 lbs)
ball screw, 2.6 kN (585 lbs)

ball screw, 4.5 kN (1012 lbs)


ball screw, 6.8 kN (1529 lbs)

ball screw, 10 kN (2248 lbs)

Note! curves were generated at an ambient temperature of 21 C (70 F). Different ambient temperature and individual actuator characteristics can produce slightly different values.

www.thomsonlinear.com/hd

19

Dimensions
Dimensions

Projection

mm [inch]

Manual override input *

Cross hole rear adapter **


Type M or E

Cross hole front adapter **


Type M or E

Crossed fork hole front adapter **


Type N or F

Crossed fork hole rear adapter **


Type N or F
Female thread front adapter **
Type P or G

* Manual override input. The input hole is covered with a plastic threaded plug. When removed a 6 mm socket can be inserted and used as a crank.
** All adapters shown in the standard orientation.

Rear Adapter Dimensions [mm (in)]

Front Adapter Dimensions [mm (in)]

Adapter Type

Adapter Type

B1

13.4 (0.53)

13.4 (0.53)

13.4 (0.53)

13.4 (0.53)

C1

B2

21.6 (0.85)

21.6 (0.85)

21.6 (0.85)

21.6 (0.85)

C2 10.9 (0.429) 10.9 (0.429) 12.9 (0.508) 12.9 (0.508)

B3

25.4 (1.0)

25.4 (1.0)

25.4 (1.0)

25.4 (1.0)

C3

30 (1.18)

30 (1.18)

see table on page 21

see table on page 21

B4 12.2 E9 (0.48) 12.8 (0.506) 12.2 E9 (0.48) 12.8 (0.506)

C4 12.2 E9 (0.48) 12.8 (0.506) 12.2 E9 (0.48) 12.8 (0.506)

M12 1.75 1/2-20 NF-2B

B5

C5

8.2 (0.323)

8.2 (0.323)

19 (0.748)

19 (0.748)

C6

35 (1.38)

35 (1.38)

20

8.2 (0.323)

8.2 (0.323)

www.thomsonlinear.com/hd

Electrak HD

Dimensions
Maximum Dynamic Load and Stroke Relationships
Maximum
Dynamic
Load (Fx)
[kN (lbs)]

Total Length (Ltot),


Retracted Length
(A) and Adapter
Dimensions [mm]

Ordering Stroke (S) [mm]


100 500

550 600

650 700

A
C1

S + 150.9 + B2 + C1
Type M, E

17.5

Type N, F

26.5

Type P, G

23.9

C3

30.16

Ltot

A + B1 + C2

A + B1 + C2

S + 150.9 + B2 + C1

S + 156.8 + B2 + C1

Type M, E

17.5

24.0

Type N, F

26.5

27.0

Type P, G

23.9

24.9

30.16

34.93

A
2.6
(585)

C1

C3
Ltot

A + B1 + C2

A + B1 + C2

S + 150.9 + B2 + C1

S + 156.8 + B2 + C1

Type M, E

17.5

24.0

Type N, F

26.5

27.0

Type P, G

23.9

24.9

30.16

34.93

A
4.5
(2012)

C1

C3
Ltot

A + B1 + C2

A + B1 + C2

S + 150.9 + B2 + C1

S + 156.8 + B2 + C1

Type M, E

17.5

24.0

Type N, F

26.5

27.0

Type P, G

23.9

24.9

30.16

34.93

A
6.8

C1

(1529)
C3
Ltot

A + B1 + C2

A + B1 + C2

S + 180.9 + B2 + C1

S + 182 + B2 + C1

Type M, E

17.5

24.0

Type N, F

26.5

27.0

Type P, G

23.9

24.9

30.16

34.93

A
10
(2248)

C1

950 1000

A + B1 + C2

Ltot

1.7
(382)

750 900

C3

www.thomsonlinear.com/hd

21

Control Options
Electrak HD feature the Electrak Modular Control System. Each unit is shipped with the
Electronic Monitoring Package. A generous offering of optional control and feedback features
can be configured to fit most applications all within the same design envelope. Details for each
control option and its wiring are described on the following pages. Please contact customer
support for more information at www.thomsonlinear.com/cs.
Control Option Type EXX
Actuator supply voltage
HD12
HD24

Control Option Type ELX


[Vdc]

Actuator current draw

[A]

9 - 16
18 - 32
see page 17

Actuator supply voltage


HD12
HD24

[Vdc]

Actuator current draw

[A]

Output contact type

9 - 16
18 - 32
see page 17
potential free

Limit switch max. switch voltage

[Vdc]

140

Limit switch max. switch current

[mA]

350

Limit switch max. switch power

[W]

red
black

red
black
red
white
not used

brown

F Fuse
S1 Double pole double throw switch

Control option EXX contains all of the basic Electrak


Monitoring Package features described on page 7,
guaranteeing safe operation of the actuator and
equipment. With control option EXX, the polarity
of the motor voltage is switched by a customer
supplied switch (switch, relay, etc.) to make the
actuator extend or retract. The switch, power supply,
wiring and all other components must be able to
handle the motor current for the actuator model and
load being used, as well as the inrush current (up to
three times the max. continuous current for the max.
load being used for up to 150 milliseconds).
22

blue
black
output fully retracted

violet

output fully extended

orange

common

grey

F Fuse
S1 Double pole double throw switch

Control option ELX works as option EXX but also has


two outputs that indicate when the extension tube is
in its fully extended or retracted position.

www.thomsonlinear.com/hd

Electrak HD

Control Options
Control Option Type EXP

Control Option Type EXD

Actuator supply voltage


HD12
HD24

[Vdc]

Actuator current draw

[A]

Potentiometer type
Potentiometer max. input voltage

9 - 16
18 - 32

Actuator supply voltage


HD12
HD24

see page 17

Actuator current draw

wirewound

Encoder type

[Vdc]

[A]

32

Encoder input voltage

[Vdc]

Potentiometer max. power

[W]

[Vdc]

Potentiometer linearity

[%]

0.25

Encoder output voltage levels


low (logical zero), typical / max.

[ohm/mm]

65.62
32.81
19.69
9.84

see page 17
hall effect

[Vdc]

Potentiometer output resolution


50 - 100 mm stroke
150 - 250 mm stroke
300 - 500 mm stroke
550 - 1000 mm stroke

9 - 16
18 - 32

Encoder resolution
HDxx-B026
HDxx-B045
HDxx-B068
HDxx-B100

[mm/pulse]

4 - 24
0.1 / 0.25
0.154
0.092
0.068
0.040

red
red
black
red

+ 32 Vdc

black
+ 5 Vdc

red

encoder output

white

white

potentiometer output
not used

not used

brown
blue

O Vdc

violet
not used

blue
black

black

0 Vdc

brown

violet
not used

orange

orange
grey

grey

F Fuse
S1 Double pole double throw switch

F Fuse
S1 Double pole double throw switch

Control option EXP works as option EXX but also has


an analog (potentiometer) output that will provide
feedback on the extension tube position.

Control option EXD works as option EXX but also has


a single channel encoder output that will provide
feedback on the extension tube position.

www.thomsonlinear.com/hd

23

Control Options
Control Option Type ELP

Control Option Type ELD

Actuator supply voltage


HD12
HD24

[Vdc]

Actuator current draw

[A]

Output contact type

9 - 16
18 - 32

Actuator supply voltage


HD12
HD24

see page 17

Actuator current draw

potential free

Output contact type

[Vdc]

[A]

9 - 16
18 - 32
see page 17
potential free

Max. output voltage

[Vdc]

140

Max. output voltage

[Vdc]

140

Max. output current

[mA]

350

Max. output current

[mA]

350

Max. ouput power

[W]

Max. ouput power

[W]

Potentiometer type

wirewound

Potentiometer max. input voltage

Encoder type

hall effect

[Vdc]

32

Encoder input voltage

[Vdc]

Potentiometer max. power

[W]

[Vdc]

Potentiometer linearity

[%]

0.25

Encoder output voltage levels


low (logical zero), typical / max.

Potentiometer output resolution


50 - 100 mm stroke
150 - 250 mm stroke
300 - 500 mm stroke
550 - 1000 mm stroke

[ohm/mm]

65.62
32.81
19.69
9.84

Encoder resolution
HDxx-B026
HDxx-B045
HDxx-B068
HDxx-B100

[mm/pulse]

red

potentiometer output
not used

red
white

output fully retracted

violet

output fully extended

orange

common

red

+ 5 Vdc

white

encoder output

grey

brown

not used

blue
black

0.154
0.092
0.068
0.040

black

brown

0 Vdc

0.1 / 0.25

red

black
+ 32 Vdc

blue

O Vdc

black

output fully retracted

violet

output fully extended

orange

common

grey

F Fuse
S1 Double pole double throw switch

F Fuse
S1 Double pole double throw switch

Control option ELP works as option EXP but also has


two outputs that indicates when the extension tube
is in its fully extended or retracted position.

Control option ELD works as option EXD but also has


two outputs that indicates when the extension tube
is in its fully extended or retracted position.

24

www.thomsonlinear.com/hd

Electrak HD

Control Options
Control Option Type LXX

Control Option Type LLX

Actuator supply voltage


HD12
HD24

[Vdc]

Actuator current draw

[A]

9 - 16
18 - 32
see page 17

Actuator supply voltage


HD12
HD24

[Vdc]

Actuator current draw

[A]

9 - 16
18 - 32
see page 17

Extend / retract input voltage

[Vdc]

9 - 32

Output contact type

potential free

Extend / retract input current

[mA]

6 - 22

Max. switched output voltage

[Vdc]

140

Max. output current

[mA]

350

Max. ouput power

[W]

Extend / retract input voltage

[Vdc]

9 - 32

Extend / retract input current

[mA]

6 - 22

red
black
red
white
not used

brown

red

blue

black

black
+

orange

output fully extended

grey

F Fuse
S1 Extend switch
S2 Retract switch

Control option LXX has all the basic Electrak


Monitoring Package features included in control
option EXX, but the polarity of the motor voltage is
switched by the onboard electronics instead. The
customer supplied switches used to command the
actuator to extend or retract only need to handle low
level signals. However, the power supply and wiring
that supplies the actuator must be able to handle the
motor current for the actuator model and load being
used, as well as the inrush current (up to one and a
half times the max. continuous current for the max.
load being used for up to 150 milliseconds).

www.thomsonlinear.com/hd

common

violet

not used
output fully retracted
+

red
white
brown
blue
black
violet
orange
grey

F Fuse
S1 Extend switch
S2 Retract switch

Control option LLX works as option LXX but also has


two outputs that indicates when the extension tube
is in its fully extended or retracted position.

25

Control Options
Control Option Type LXP

Control Option Type CNO

Actuator supply voltage


HD12
HD24

[Vdc]

Actuator current draw

[A]

Potentiometer type
Potentiometer max. input voltage

9 - 16
18 - 32
see page 17

Actuator current draw

wirewound

Command data includes:


position
speed
current

[Vdc]

32

Potentiometer max. power

[W]

Potentiometer linearity

[%]

0.25

Potentiometer output resolution


50 - 100 mm stroke
150 - 250 mm stroke
300 - 500 mm stroke
550 - 1000 mm stroke

[ohm/mm]

Actuator supply voltage


HD12
HD24

65.62
32.81
19.69
9.84

Extend / retract input voltage

[Vdc]

9 - 32

Extend / retract input current

[mA]

6 - 22

[Vdc]

[A]

9 - 16
18 - 32
see page 17

Feedback data includes:


position
speed
current
other diagnostic information

red
black
red

address select 3
not used

red
black
32 Vdc
potentiometer output
not used
0 Vdc
+

red
white
brown
blue

CAN low

brown

CAN high

blue
not used

black

address select 1

violet

address select 2

orange

address select common

grey

black
violet

F Fuse

orange
grey

F Fuse
S1 Extend switch
S2 Retract switch

Control option LXP works as option LXX but also has


an analog (potentiometer) output that will provide
feedback on the extension tube position.

26

white

Control option CNO has a J1939 CAN bus control


interface that controls and monitors the actuator.
Extend and retract commands are sent via CAN
messages on the CAN low and CAN high pins.
Address select 1, 2, and 3 pins can be used a BCD
encoded adder to the default address. This can be
used when multiple J1939 actuators are located on
a single bus.

www.thomsonlinear.com/hd

Electrak HD

Accessories
Limit Switches for Cover Tube Mounting

Rod End Front Adapter

Sensor type

Type

solid state

reed switch

Contact type

normally open (N.O.)

Material

Output type

PNP

contact

10 - 30 /

5 -120 / 5 -120

Dimensions
A
B
C

Voltage

[VDC/AC]

Max. current

[mA]

Hysteresis

[mm]

1.5

1.0

[C]

- 25 to + 85

- 25 to + 85

Operating temperature

100

p/n

Lead cross section

[mm ]

3 0.14

2 0.14

Length (L)

[mm]

25.3

30.5

IP69K

IP67

Protection class
LED indicator

metric

inch

CAD plated steel


12.0 0.1 mm
14.3 0.1 mm
M12

0.5 in
0.625 in
1/2-20 UNF

756-9021

756-9007

Dimensions [mm (in)]

yes

Connection

2 m cable with flying leads

p/n

840-9131

840-9132

Mounting positions

The rod end front adapter comes in one metric


and one inch version. The metric adapter can be
mounted to the front of the extension tube if the
actuator is equipped with the metric female thread
front adapter option (type P) while the inch adapter
requires the inch female thread option (type G).

Sensors

Dimensions [mm]

Connection
Solid state

Reed switch
brown

+ VDC

blue

- VDC

black

output

brown

input

blue

output

The limit switches are mounted in the cover tube


slots and will be switched by a magnet mounted
inside of the actuator on the extension tube.
www.thomsonlinear.com/hd

27

Online Resources
Thomson offers a wide variety of online application, selection, and training tools to help you in
the selection process. An experienced team of application engineers is also available to help
size and select an Electrak HD model to best fit your application needs. To explore additional
technical resources and options, contact Thomson customer support at www.thomsonlinear.
com/hd.
Electrak HD Microsite
Get additional information and learn more about the electromechanical advantage on our microsite.
www.thomsonlinear.com/hd

image of site

Product Selector
The product selector will walk you through the
selection process. www.thomsonlinear.com/
website/com/eng/products/actuators/linear_
actuators_selector.php

28

Interactive 3D CAD Models


Download interactive 3D CAD models in the most
common CAD formats for free. www.thomsonlinear.
com/micro/electrakhd_eng/3d-model.html

www.thomsonlinear.com/hd

Electrak HD

Leverage Decades of Design and Application Expertise


Thomson is the market share leader for electric linear actuators in the most demanding
applications, such as construction and agriculture vehicles. We routinely collaborate with
original equipment manufacturers globally to solve problems, boost efficiency and enhance the
value passed on to their customers. Global contact information is available at
www.thomsonlinear.com/cs.
From the pioneer in industrial actuators comes a legacy of technologies and application
experience that can be harnessed to help with your next machine design, too.
Call today, and lets talk about how our vast offering of standard, modified standard and custom
solutions can deliver the optimal balance of performance, life and installed cost for you.

1965

1967

Thomson Performance
Pak electromechanical
actuators are developed.

The first actuators for


use in garden tractors
and farm equipment is
released.

2007

2012

Electrak Pro series


released.

WhisperTrak series
released.

www.thomsonlinear.com/hd

1974

1982

1987

2013

2013

2016

First line of actuators


with parallel motors and
both acme and ball screw
drive is released.

Electrak Throttle is
released.

The Electrak line of


actuators are released.

Max Jac heavy duty


actuator released.

Electrak 205 and the first


line of MCS controls are
released.

Electrak HD is released.

29

Frequently Asked Questions


Here are the answers to common questions. Please contact customer support if you need more
information at www.thomsonlinear.com/cs.
What is the typical life of an actuator?
Life is a function of load and stroke length. Please
contact customer support for more information.
What are the most common reasons for
premature actuator failure?
Side load due to incorrect mounting, shock loading,
exceeding the duty cycle and incorrect wiring are the
most prominent causes for premature failure.
What are IP ratings?
IP ratings (International Protection Marking) are
commonly referenced standards which classify
electrical equipment using standard tests to
determine resistance to ingress of solid objects (first
digit) and liquids (second digit). See the IP Ratings
table, below.

Is Electrak HD suitable for tough environments,


such as wash-down or extreme temperatures?
Yes. Electrak HD actuators are designed for wash
down and have passed 200 hours of salt spray tests.
They can operate in temperatures ranging from -40
(-40) to + 85 (185) Celsius (Fahrenheit).
How is the duty cycle determined?
The duty cycle = on time / on time + off time. For
example, if Electrak HD is powered for 15 seconds
and then off for 45 seconds, the duty cycle for that
minute would be 25%. All models are rated to 25%
at full load and an ambient temperature of 25 C (77
F). If load and/or ambient temperature are lower,
then the duty cycle can exceed 25%. At higher
temperatures the duty cycle will be lower. Also see
the duty cycle vs. load curve on page 19.

IP Rating
Code

30

First Digit Definition

Second Digit Definition

No protection.

No protection.

Protected against solid objects over 50 mm.

Protected against vertically falling drops of water.

Protected against solid objects over 12.5 mm.

Protected against vertically falling drops of water, if the case is


disposed up to 15 from vertical

Protected against solid objects over 2.5 mm.

Protected against vertically falling drops of water, if the case is


disposed up to 60 from vertical

Protected against solid objects over 1 mm.

Protected against splash water from any direction.

Limited protection against dust ingress (no harmful deposits).

Protected against low pressure water jets from any direction.


Limited ingress permitted.

Totally dust protected.

Protected against high pressure water jets from any direction.


Limited ingress permitted.

Protected against short periods of immersion in water.

Protected against long, durable periods of immersion in water.

9K

Protected against close-range high pressure, high temperature


spray downs.

www.thomsonlinear.com/hd

Electrak HD

Is Electrak HD maintenance free?


Yes. Electrak HD never requires lubrication,
maintenance or adjustment for wear.
Is it possible for a load to back-drive the
extension tube?
No. The ball screw models incorporate a static load
holding brake.
What is the difference between a tension and a
compression load?
A tension load tries to stretch the actuator,
while a compression load tries to compress it.
With bi-directional loads, the end play of the
actuator extension tube may need to be taken
into consideration when using the actuator for
positioning tasks.

Load

Load

Tension

Compression

Can Electrak HD be side loaded?


No. A proper design of the application should
eliminate any side loads.
What is the range of input voltage an Electrak
HD can operate with?
A 12 Vdc version will accept 9 16 Vdc, while a
24 Vdc version will accept 18 32 Vdc. Outside of
these limits, the Electronic Monitoring Package will
prevent the actuator from operating.

www.thomsonlinear.com/hd

Can the speed of an Electrak HD be adjusted by


changing the input voltage?
No. As long as the input voltage is within the
acceptable limits, the Electronic Monitoring Package
will keep each Electrak HD at the correct speed for
the load in question.
What is the inrush current?
The inrush current is a short current peak that
appears at the start of an actuator as the motor
tries to get the load moving. Typically, the inrush
current will last between 75 to 150 milliseconds
and can be up to three times higher (on a low-level
switched actuator 1.5 times higher) than the current
for the actuator and load. Batteries have no problem
delivering the inrush current, but if using an AC
powered power supply, it is important to size it to
handle the inrush current.
What special mounting considerations does
the Electrak HD require?
There is no restraining torque that needs to be
considered, as Electrak HD is internally restrained.
However, the actuator must be mounted so that
there are no side loads acting on the extension tube.
It is also important that the manual override input
is accessible after the actuator is mounted and that
connectors and cables are placed so that they are
not damaged during operation.
What is the maximum extension speed?
The extension speed of an Electrak HD actuator is
a function of the load. To determine the speed at a
certain load, consult the load vs. speed charts on
page 19. If a higher linear travel is required, a simple
mechanical linkage can be employed.

31

USA, CANADA and MEXICO


Thomson
203A West Rock Road
Radford, VA 24141, USA
Phone: 1-540-633-3549
Fax: 1-540-633-0294
E-mail: thomson@thomsonlinear.com
Literature: literature.thomsonlinear.com
EUROPE
United Kingdom
Thomson
Office 9, The Barns
Caddsdown Business Park
Bideford
Devon, EX39 3BT
Phone: +44 (0) 1271 334 500
E-mail: sales.uk@thomsonlinear.com
Germany
Thomson
Nrtinger Strae 70
72649 Wolfschlugen
Phone: +49 (0) 7022 504 0
Fax: +49 (0) 7022 504 405
E-mail: sales.germany@thomsonlinear.com
France
Thomson
Phone: +33 (0) 243 50 03 30
Fax: +33 (0) 243 50 03 39
E-mail: sales.france@thomsonlinear.com
Italy
Thomson
Largo Brughetti
20030 Bovisio Masciago
Phone: +39 0362 594260
Fax: +39 0362 594263
E-mail: info@thomsonlinear.it
Spain
Thomson
E-mail: sales.esm@thomsonlinear.com
Sweden
Thomson
Estridsvg 10
29109 Kristianstad
Phone: +46 (0) 44 24 67 00
Fax: +46 (0) 44 24 40 85
E-mail: sales.scandinavia@thomsonlinear.com

ASIA
Asia Pacific
Thomson
E-mail: sales.apac@thomsonlinear.com
China
Thomson
Rm 2205, Scitech Tower
22 Jianguomen Wai Street
Beijing 100004
Phone: +86 400 6661 802
Fax: +86 10 6515 0263
E-mail: sales.china@thomsonlinear.com
India
Thomson
c/o Fluke Technologies Pvt. Ltd.
#424, Deodhar Center,
Marol Maroshi Road,
Andheri E, Mumbai 400059 India
Phone: +91 22 29207641
E-mail: sales.india@thomsonlinear.com
Japan
Thomson
Minami-Kaneden 2-12-23, Suita
Osaka 564-0044 Japan
Phone: +81-6-6386-8001
Fax: +81-6-6386-5022
E-mail: csjapan@scgap.com
Korea
Thomson
F7 Ilsong Bldg, 157-37
Samsung-dong, Kangnam-gu,
Seoul, Korea (135-090)
Phone: +82 2 6917 5049
Fax: +82 2 528 1456
E-mail: sales.korea@thomsonliear.com
SOUTH AMERICA
Brazil
Thomson
Av. Tambor, 1077
Barueri, SP 06460-000
Phone: +55 (11) 3616-0191
Fax: +55 (11) 3611-1982
E-mail: sales.brasil@thomsonlinear.com

www.thomsonlinear.com
Electrak_HD_Actuator_BREN-0020-03A | 20160425TJ
Specifications are subject to change without notice. It is the responsibility of the product user to determine the suitability of
this product for a specific application. All trademarks property of their respective owners. Thomson Industries, Inc. 2016

32

www.thomsonlinear.com/hd