Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
1 of 15
https://archive.sap.com/discussions/thread/259179
Get Started
11/1/2016 9:01 AM
Enhancement Error
2 of 15
https://archive.sap.com/discussions/thread/259179
/
/
Archives
Discussions Archive
Enhancement Error
Hi ,
To Know enhancement concept I Enhanced 2LIS_11_VAHDR Data source . I followed following steps .
1. SE11 ,Gave Extract Structure name ,Append Structure ,Appended
1. Matnr
2. Lgort
Then Activated .
Now when i came to LBWE and try to Click 'Inactive' to activate it is showing errors
<b>In program "SAPLMCEX ", the following syntax error occurred
in the Include "MCEX11TOP " in line 14:
""MC11VA0HDR" must be a flat structure. You cannot use internal tables,"
" strings, references, or structures as components ." </b>
If i try to generate data source by clicking data source name it shows following error
Warning
Extraction structure includes invalid field LGORT with ABAP type
<b>Error
Event with errors Extract in DataSource 2LIS_11_VAHDR</b>
How to solve this , now i am not even able to activate the data source .....?
Thanks & Regards
BI Begineer
November 20, 2006 at 09:54 AM
0 Likes
11/1/2016 9:01 AM
Enhancement Error
3 of 15
https://archive.sap.com/discussions/thread/259179
Arun Varadarajan
replied
November 20, 2006 at 10:00 AM
BI,
I think you might be using referenced fields like
Amount / Quantity etc - these require the units fields
also to be able to be activated...
Arun
P.S check the forums for posts having "Invalid
Extraction Structure" that would give you the answers
you require...
0
Nandu BPC
replied
November 20, 2006 at 10:06 AM
Hi
1) go to se38 and
check the
SAPLMCEX
program what kind
of erors it is giving..
2) did u wrote the
USER exit.. to
populate the
extractstructure
from the table field
hope it helps
regards
AK
11/1/2016 9:01 AM
Enhancement Error
4 of 15
https://archive.sap.com/discussions/thread/259179
AK
0
ramakanth gandepalli
replied
November 20, 2006 at 10:08 AM
Hi Beginner,
1.Before doing enhancements we need to delete the
setup tables.
2.I am having enhancements step by step
document.Send your mail id i will send the document.
My Mail : gandepally@yahoo.co.in
Thanks
Ramakanth
0
Davide Cavallari
replied
November 20, 2006 at 10:26 AM
Hi BI Begineer,
your error message is:
<i>MC11VA0HDR must be a flat structure. You
cannot use internal tables,
strings, references, or <b>structures</b> as
components.
Extraction structure includes invalid field
<b>LGORT</b> with ABAP type [...]</i>
If you look at the object LGORT in the dictionary (use
the transaction code SE11, data type display), you'll
see there's a <b>structure</b> with name LGORT, as
well as a <b>domain</b>. Can you check what is the
<b>data type</b> of the field LGORT you've
appended to the extract structure MC11VA0HDR?
11/1/2016 9:01 AM
Enhancement Error
5 of 15
https://archive.sap.com/discussions/thread/259179
BI Begineer
replied
replied
Hi ,
My id : pmani_35@yahoo.co.in
Thanks & Regards
0
BI Begineer
Hi david ,
You are right , for MATNR i used MATNR (Data Elemet is correct ) , But for
LGORT
i used LGORT ( It is a structure ) But i should have used data element name
LGORT_D .
That is the problem . Now how to change that LGORT TO LGORT_D.
Thanks & Regards
0
Davide Cavallari
replied
November 20, 2006 at 10:52 AM
Hello,
11/1/2016 9:01 AM
Enhancement Error
6 of 15
https://archive.sap.com/discussions/thread/259179
Hello,
I'm glad you could figure out the problem. Now
you should delete the LGORT entry from the
append structure. Then you can add the
component LGORT again, specifying the
component type LGORT_D.
Regards, Davide
0
BI Begineer
replied
Hi ramakanth ,
I gave my id pmani_35@yahoo.co.in ,,,,Kindly send that step by step doc to this
id . I am in the initial stage of extraction .
Thanks in advance
0
ramakanth gandepalli
replied
November 20, 2006 at 10:51 AM
HI Beginner
I have sent the docuements to your mail-id.
Regards
Ramakanth.
Assign points if useful
0
11/1/2016 9:01 AM
Enhancement Error
7 of 15
https://archive.sap.com/discussions/thread/259179
BI Begineer
replied
Hi ,
Thanks David .
I just went to 'Append Structure ' , Display - Change , Changed LGORT To
LGORT_D , Activated , Problem Sloved .
Ramakanth ,Points assigned .
0
Davide Cavallari
replied
November 27, 2006 at 12:19 PM
Hello BI Begineer,
the technical problem on the SDN website has
been solved. Could you please close this topic,
so other users can see this problem as
solved?
Thanks, Davide
0
BI Begineer
replied
At present some error is showing in point assignment ,will assign when that is
cleared .
One more question .
I need meaning of enhancement ?
LGORT , MATNR are standard fields , i am nowincluding that in standard extract
structure , Can i call this as enhancement or
If i use my Z***** own field in extract structure, then that is called enhanceent
What is true ? .
11/1/2016 9:01 AM
Enhancement Error
8 of 15
https://archive.sap.com/discussions/thread/259179
What is true ? .
Thanks
0
Davide Cavallari
replied
November 20, 2006 at 11:15 AM
BI Begineer
replied
Hi david ,
So Not only adding User defined Z***** fields to extract structure , Adding SAP
defined standard fields is also enhancements. Both are enhancements Right .
Now What is the steps to be done to get the MATNR , LGORT data into the
extract structure .
Thanks
0
11/1/2016 9:01 AM
Enhancement Error
9 of 15
https://archive.sap.com/discussions/thread/259179
Davide Cavallari
replied
November 20, 2006 at 14:15 PM
1. CASE I_DATASOURCE.
2.
WHEN '2LIS_11_VAHDR'.
3.
4. ENDCASE.
11/1/2016 9:01 AM
Enhancement Error
10 of 15
https://archive.sap.com/discussions/thread/259179
Davide Cavallari
0
BI Begineer
replied
11/1/2016 9:01 AM
Enhancement Error
11 of 15
https://archive.sap.com/discussions/thread/259179
Davide Cavallari
replied
November 21, 2006 at 10:04 AM
11/1/2016 9:01 AM
Enhancement Error
12 of 15
https://archive.sap.com/discussions/thread/259179
thanks
Message was edited by:
Davide Cavallari
0
BI Begineer
replied
Hi David ,
Thanks a Lot for you valuable help ..... Your each reply is worth to get points
Definetly i will assign points , This thread will give you max points bcos your
replies are more here , But still now SDN is showing some error in Point
assignments , It happens frequently but clears soon ...... Assigning points is my
duty , I wont forget .
Now i am not doing enhancement in Prod Server ,<b>Since iam new to
enhancement i am trying that in IDES only</b> , IDES dodent need authorization.
If this is succesful i can do that in our Prod sys.
Regards
0
Davide Cavallari
replied
November 21, 2006 at 10:44 AM
11/1/2016 9:01 AM
Enhancement Error
13 of 15
https://archive.sap.com/discussions/thread/259179
BI Begineer
replied
Thanks David
But why cant edit the code in editor in Change mode in Inclue part of Exit . What
is the procedure . Only if i can write code and activate then only my changes in
data source takes effect ....Kindly tell me procedure
Regards
0
Davide Cavallari
replied
November 21, 2006 at 11:04 AM
11/1/2016 9:01 AM
Enhancement Error
14 of 15
https://archive.sap.com/discussions/thread/259179
BI Begineer
replied
Hi david ,
My system is ides , Ehen i click Disp -> Change the some Exits code change
from Disp To change mode .
But some change from Blue (Display ) , In between White (Change ) ,
Immediately letters turs to Grey ( We cannot edit that ).
This is the problem now
Thanks
0
Davide Cavallari
replied
November 21, 2006 at 11:53 AM
Davide Cavallari
replied
November 21, 2006 at 12:13 PM
11/1/2016 9:01 AM
Enhancement Error
15 of 15
https://archive.sap.com/discussions/thread/259179
Privacy