Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
/usr/lib/osa/bin/lad
nected to the system
c2t0d0 1T04359725 LUNS: 0 1
/usr/lib/osa/bin/healthck <c2t0d0>
device
Health Check Summary Information
mya1000_001:
Failed Battery
# <-- Failing
# <-- Disk in
battery
mya1000_001:
bad state
healthck succeeded!
/usr/lib/osa/bin/raidutil -c <c2t0d0>
the device
LUNs found on c2t0d0.
LUN 0
RAID 0
103407 MB
LUN 1
RAID 0
103407 MB
raidutil succeeded!
/usr/lib/osa/bin/raidutil -c <c2t0d0> -i
LUNs found on c2t0d0.
LUN 0
RAID 0
103407 MB
LUN 1
RAID 0
103407 MB
# Detailed information
Vendor ID
Symbios
ProductID
StorEDGE A1000
Product Revision 0301
Boot Level
03.01.02.33
Boot Level Date 06/16/99
Firmware Level
03.01.02.35
Firmware Date
08/12/99
raidutil succeeded!
/usr/lib/osa/bin/raidutil -c <c2t0d0> -B
# Information about battery
life
LUNs found on c2t0d0.
LUN 0
RAID 0
103407 MB
LUN 1
RAID 0
103407 MB
Battery age is between 810 days and 900 days.
raidutil succeeded!
# Battery age:
#
Between 630 and 720 days - near expiration
#
More than 720 das - Expired
# In any of two previous cases battery should be replaced
/usr/lib/osa/bin/raidutil -c <c2t0d0> -R
r
EEN REPLACED!!!
/usr/lib/osa/bin/drivutil -I <c2t0d0>
No. of
LUNs
1
2
RAID
Level
No. of
Drives
0
0
6
6
1
1
Total
Space(MB)
Remaining
Space(MB)
103407
103407
0
0
drivutil succeeded!
/usr/lib/osa/bin/drivutil -i <c2t0d0>
the drives
Status
Vendor Product
Firmware
Serial
(MB)
ID
Version
Number
[1,0]
3BT1BM1N00
[2,0]
3BT0ZW4E00
[1,1]
3JKP6AD900
[2,1]
3BT19FG200
[1,2]
3BT1BFZP00
[2,2]
3BT1C09X00
[1,3]
3BT1CC6T00
[2,3]
3BT1BSBJ00
[1,4]
3BT1BHY800
[2,4]
3BT1CDN300
[1,5]
00391G1084
[2,5]
3BT1C5TT00
17274
Optimal
17274
Optimal
17274
Optimal
17274
Optimal
17274
Optimal
17274
Optimal
17274
Optimal
17274
Optimal
17274
Optimal
17274
Optimal
17274
Optimal
IBM
17274
Optimal
drivutil succeeded!
DDYST1835SUN18G S94N
/usr/lib/osa/bin/rm6
face