Sei sulla pagina 1di 12

Load Records

Number of Name of BuArea Name Zone NameID


33
1
1
3
44
1
1
4
55
1
1
5
66
1
1
6

Status
Closed
Closed
Closed
Closed

MW
55
0
30
50

Mvar

MVA
13
0
18
5

S MW
56.52
0
34.99
50.25

S Mvar
55
0
30
50

13
0
18
5

Line Records
From NumbFrom NameTo Number To Name
11
44
11
66
33
22
55
22
44
33
44
66
66
55

Circuit
1
1
1
1
1
1
1

Status
Closed
Closed
Closed
Closed
Closed
Closed
Closed

Branch Device Type


Line
Line
Line
Line
Transformer
Line
Transformer

Xfrmr
NO
NO
NO
NO
YES
NO
YES

MW From Mvar From MVA From Lim MVA


51.5
29.1
59.1
65
45.3
23.4
51
55
-16
-0.1
16
40
-28
-9.2
29.5
55
39
15.9
42.1
50
9.8
2.3
10.1
30
2
9.1
9.3
30

% of MVA LiMW Loss Mvar Loss


91
2.69
12.44
92.8
3.08
12.97
47
2.46
3.57
65.3
3.49
7.93
84.2
0
2.98
33.6
0.11
0.52
31.1
0
0.34

Gen Records
Number of Name of BuID
11
1
22
2

Status
Closed
Closed

Gen MW
Gen Mvar Set Volt
96.83
52.5
1.02
50
20.78
1.02

AGC
YES
YES

AVR
YES
YES

Min MW

Max MW Min Mvar Max Mvar Cost Model


40
200
-50
100 None
20
100
-25
50 None

Part. Factor
10
10

Bus Records
Number
Name
55
33
66
44
22
11

fdlf
Area Name Nom kV
PU Volt
Volt (kV) Angle (Deg
1
138
0.83881
115.756
-13.89
1
138
0.86747
119.711
-14.48
1
138
0.87022
120.091
-13.43
1
138
0.88933
122.728
-10.62
1
138
1.02
140.76
-3.56
1
138
1.02
140.76
0

Load MW Load Mvar Gen MW


Gen Mvar Switched S Act G Shun Act B Shun
30
18
0
0
55
13
0
0
50
5
1.89
0
0
0
0
1.58
0
0
50
20.78
0
0
96.83
52.5
0
0

Area Num Zone Num


1
1
1
1
1
1
1
1
1
1
1
1

Load Flow Analysis by Fast Decoupled Method


Gen Records
Number of Bus

Name of Bus

ID

Status

Gen MW

Gen Mvar

Set Volt

AGC

AVR

Min MW

Max MW

Min Mvar

Max Mvar

Cost Model

Part. Factor

1
2

1
2

1
2

Closed
Closed

96.83
50

52.5
20.78

1.02
1.02

YES
YES

YES
YES

40
20

200
100

-50
-25

100
50

None
None

10
10

Number

Name

Area Name

Nom kV

PU Volt

Volt (kV)

Angle (Deg)

Load MW

Load Mvar

Gen MW

Gen Mvar

Switched
Shunts Mvar

Act G Shunt MW

Act B Shunt
Mvar

Area Num

Zone Num

5
3

5
3

1
1

138
138

0.83881
0.86747

115.756
119.711

-13.89
-14.48

30
55

18
13

0
0

0
0

1
1

1
1

6
4

6
4

1
1

138
138

0.87022
0.88933

120.091
122.728

-13.43
-10.62

50
0

5
0

0
0

0
0

1
1

1
1

2
1

2
1

1
1

138
138

1.02
1.02

140.76
140.76

-3.56
0

0
0

0
0

1
1

1
1

From Number

From Name

To Number

To Name

Circuit

Status

Branch Device Type

Xfrmr

MW Loss

Mvar Loss

Closed

Line

2.69

12.44

1
3

1
3

6
2

6
2

1
1

Closed
Closed

5
4
4

5
4
4

2
3
6

2
3
6

1
1
1

Number of Bus

Name of Bus

Area Name of
Load

4
5

4
5

Bus Records

1.89
1.58
50
96.83

20.78
52.5

MW From

Mvar From

MVA From

Lim MVA

NO

51.5

29.1

59.1

65

% of MVA
Limit (Max)
91

Line
Line

NO
NO

45.3
-16

23.4
-0.1

51
16

55
40

92.8
47

3.08
2.46

12.97
3.57

Closed
Closed
Closed

Line
Transformer
Line

NO
YES
NO

-28
39
9.8

-9.2
15.9
2.3

29.5
42.1
10.1

55
50
30

65.3
84.2
33.6

3.49
0
0.11

7.93
2.98
0.52

Closed

Transformer

YES

9.1

9.3

30

31.1

0.34

Zone Name of
Load

ID

Status

MW

Mvar

MVA

S MW

S Mvar

Closed

55

13

56.52

55

13

1
1

1
1

4
5

Closed
Closed

0
30

0
18

0
34.99

0
30

0
18

Closed

50

50.25

50

Line Records

Load Records

Switched Shunt Records


Number of Bus

Name of Bus

ID

Reg Bus Num

Status

Control Mode

Regulates

Actual Mvar

Volt High

Volt Low

Reg Volt

Deviation

Nominal Mvar

Max Mvar

Min Mvar

Closed

Fixed

Volt

1.58

0.99

0.8893

-0.1007

Closed

Fixed

Volt

1.89

0.99

0.8702

-0.1198

2.5

2.5