SL.NO.
A
C
1
2
DESCRIPTION
AMBIENT CONDITIONS
Dry Bulb / Wet Bulb / RH
INSIDE DESIGN CONDITIONS
Dry Bulb / Wet Bulb / RH
State any special requirements for the coil
Hydrofilic blue fins
Copper Header with MS Adapter
Any thickness of tube other than 0.41mm
Whether High Delta 'T' ?
If Coil rows deep has been specified please furnish
DESIGN PARAMETERS
WHETHER COIL IS DX OR CHILLED WATER
IF DX KINDLY FILL THE FOLLOWING:a. Tonnage of Coil
b. Refrigerant
c. Ref. Evaporating Temp
d. Ref. condensing Temp
e. Number of refrigerant circuits desired
IF CHILLED WATER/BRINE FILL THE FOLLOWING
a. Tonnage of Coil
b. Design coil entering temperature
c. Design coil leaving temperature / Flow Rate
AIR SIDE PARAMETERS
a. Dehumidified Air Quantity (CFM)
b. Total Fan Air Quantity if By pass considered.(CFM)
c. Fresh Air Quantity if specified (CFM)
0.7 mm
4 row (maximum 6 row)
DX
17
R410A
6000
600
As per samsung standard
mentioned in AHU data reference
23 C
16.1 C
Electric Type
3 kW
SL.NO.
A
C
1
2
DESCRIPTION
AMBIENT CONDITIONS
Dry Bulb / Wet Bulb / RH
INSIDE DESIGN CONDITIONS
Dry Bulb / Wet Bulb / RH
State any special requirements for the coil
Hydrofilic blue fins
Copper Header with MS Adapter
Any thickness of tube other than 0.41mm
Whether High Delta 'T' ?
If Coil rows deep has been specified please furnish
DESIGN PARAMETERS
WHETHER COIL IS DX OR CHILLED WATER
IF DX KINDLY FILL THE FOLLOWING:a. Tonnage of Coil
b. Refrigerant
c. Ref. Evaporating Temp
d. Ref. condensing Temp
e. Number of refrigerant circuits desired
IF CHILLED WATER/BRINE FILL THE FOLLOWING
a. Tonnage of Coil
b. Design coil entering temperature
c. Design coil leaving temperature / Flow Rate
AIR SIDE PARAMETERS
a. Dehumidified Air Quantity (CFM)
b. Total Fan Air Quantity if By pass considered.(CFM)
c. Fresh Air Quantity if specified (CFM)
0.7 mm
4 row (maximum 6 row)
DX
11
R410A
3500
350
As per samsung standard
mentioned in AHU data reference
23 C
16.1 C
Electric Type
3 kW
SL.NO.
A
C
1
2
DESCRIPTION
AMBIENT CONDITIONS
Dry Bulb / Wet Bulb / RH
INSIDE DESIGN CONDITIONS
Dry Bulb / Wet Bulb / RH
State any special requirements for the coil
Hydrofilic blue fins
Copper Header with MS Adapter
Any thickness of tube other than 0.41mm
Whether High Delta 'T' ?
If Coil rows deep has been specified please furnish
DESIGN PARAMETERS
WHETHER COIL IS DX OR CHILLED WATER
IF DX KINDLY FILL THE FOLLOWING:a. Tonnage of Coil
b. Refrigerant
c. Ref. Evaporating Temp
d. Ref. condensing Temp
e. Number of refrigerant circuits desired
IF CHILLED WATER/BRINE FILL THE FOLLOWING
a. Tonnage of Coil
b. Design coil entering temperature
c. Design coil leaving temperature / Flow Rate
AIR SIDE PARAMETERS
a. Dehumidified Air Quantity (CFM)
b. Total Fan Air Quantity if By pass considered.(CFM)
c. Fresh Air Quantity if specified (CFM)
0.7 mm
4 row (maximum 6 row)
DX
3
R410A
1200
120
As per samsung standard
mentioned in AHU data reference
23 C
16.1 C
Electric Type
1.5 kW