Inhoudsopgave error messages 4008

Error messages after turning power on

blz 1

Bios Test passed ROM Test passed RAM Test passed

blz 1

FXX Configuration
EPROM ERROR
BRAM_#_XXXX_XXXX_XXXX
RAM ERROR
Keyboard Error
Watchdog Error
XX (not calibrated)
NTC109 switched off
Error description: T1 test
F XX Bypass
F XX Opt. Detector
F XX Bloodsystem
F XX Venous
F XX Airdetector
F XX Display
F XX Arterial
F XX Accumulator
F XX Bloodleak
F XX Temperature
F XX Neg. Pressure
F XX Pos. Pressure
F XX UF function
F XX Conductivity
F XX Diasafe
F XX HDF Filter
F XX Online plus / diasafe plus / HPU
Error messages during dialysis
Voltage Failure
24 V Switched Off
CPU-II failed
Profile time diff.
Cyclical PHT FXX
V84 faultiness !
Shunt Cover open
Voltage Failure
UF1 volume Error
UF2 volume Error
FXXX UF-failure
Error Messages on 4008 Display
HPU Error
FXX Configuration
Warnings / Information
24 V Switched Off
Air in system
ASP failure
BLD dimness warning
Connect Cone Line

blz 2 t/m 27
blz 2
blz 3
blz 4 t/m 5
blz 6
blz 7 t/m 8
blz 9
blz 10
blz 11
blz 12
blz 13
blz 14
blz 15 t/m 17
blz 18 t/m 19
blz 20
blz 21
blz 22 t/m 23
blz 24 t/m 27
blz 28 t/m 30
blz 28

blz 29

blz 29 t/m 30
blz 31 t/m 33
blz 31 t/m 32
blz 33
blz 34 t/m 35
blz 34

CPU II failed
Cyclic PHT FXX
Dialines not conn
Dialyzer failure
Fillprogram
Fill-time reached
Flow off warning
Fund. Not allowed
F XXX UF failure
Hep pomp alarm
Hep pomp not on
Increase blood flow
Maxium filling time reached
Module error
No UF
Profiles paused
Profile time diff
Relation BPR/UFR
Set UF rate
Shunt cover open
Timer alarm
Timer stops UF rate
UF goal reached
V84 faultiness
Ven con. Test failed
Voltage failure
Wrong cone. Supply

Description of machine errors during


the cleaning programs. V84 monitoring

blz 34

blz 35

blz 36

Rinse failure F XX
PSW (pressure switch) monitoring

blz 37 t/m 38

Rinse failure F XX
Hydraulics test (check of V91,V99,V100)
In machines with central delivery system

blz 39

Rinse failure F11


V91/V100 Failure
V99 Failure
V130 Failure
V188 Failure
CDS Failure V104
CDS Failure V102
F14
Hydraulics test (check of V91,V99,V100)
In machines without central delivery system
F14
V91 Failure
F14

blz 40

Hydraulics test (check of V91,V99,V100,V130)


In machines with BIBAG and without central
delivery system
Rinse failure F15
V91 Failure
V100 Failure
Rinse failure F16
V99 Failure
Rinse failure F17
V130 Failure
Rinse failure F20
V188 Failure
Rinse failure F14
V39 test

blz 41 t/m 42

blz 42

blz 43

V39 Failure
Further messages which may be displayed before or during a
cleaning program.
Accumulator empty
Blood Sensed by OD
Bibag connect open
Bic line not conn
Bypass valve failed
CDS connectors open
CDS failure V145/147
Conc line not conn
Connect CDS lines
Connect desinfectant
CPU-II failed
Dialines not conn
Dial. Valve failed
Desinfectant empty?
Desinf-temp too high
Float-switch failure
Flow alarm
HDF-pomp failure
Heater error
High temperature
Low temperature
No LD alarm
Pleace Wait
Power failure
Press CONFIRM key
Remove CDS lines
Rinse after desinf.
Rinse required
Shunt cover open
UF-pomp failed
UF-pomp 2 failed
Upper flow alarm
V102 failure
V104 failure
Voltage Failure
Water alarm

blz 44 t/m 46

blz 45

blz 46

Bloedpomp foutmeldingen /stroke versie 1.30

blz 47

E XX
Strookvolume afhankelijke omschakelpunten
Error Messages ONLINE plus Module

blz 48

Watchdog error no. XX


Program error no. XX
Communication error no. XX
Valve error no. XX
T1-test error no. XX
Ref. voltage error no. 11
CRC error no. 12
EEPROM error no. 13
From monitor error no. 14
Error Messages During the Functional Test of the BVM
Software error x
System error x
Treatment error: door opend
Error Messages and Warnings Displayed by the BVM 4008
During Preparation and Treatment.
BV- control off XX
BVM not calibrated
Cuvette unsuitable
Door open
No Blood
No calibration
No communication
No saline solution
Service mode
Error Messages and Warnings Displayed by the Dialysis System
During Preparation and Treatment.
BVM error
BVM bpr too low
BVM enter critRBV
BVM Failure XX
BVM not calibrated
BVM not possible
BVM not Ready
BVM only ISO-time
BVM pArt too low
BVM uf control?
BVM UF- goal?
BVM + ISO t = .
Dialysis with BVM
First start UF
H(D)F with BVM
HDF with BVM
HF with BVM
Module error
No blood in system
SN- HDF with BVM

blz 49 t/m 50
blz 49
blz 50
blz 51 t/m 44

blz 52

blz 53 t/m 47

blz 54

SN- HF with BVM


SN with BVM
Stop UF- profile
UF- control aborted
UFR limit
Wrong UF- param.
4008 HDF with BVM
4008 HF with BVM
ERROR Messages BPM

blz 55

blz 56 t/m 58

E XXXX
Handeling of Error Messages of the BTM

blz 59 t/m 66