Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
1.0______Overview
2.0______Installing the Software
3.0______Connection setup
4.0______How to read a paramenter
5.0______How modify&store parameters
6.0______Restoring default parameters
7.0______Save File/Open File
8.0______Typical wiring diagram
9.0______Engine&Genrator Control
10.0_____Password
11.0_____Control Panel
- 1.0 - Overview -The software have full access to the Ge3000. It features the following parts:
Indication of the status of the
engine or miscellaenous
messages
Ge3000 1.14
GE3000
It loads the
defaults
It opens a file from a
folder of your PC
It reads parameters
from Ge3000
It stores parameters
into a file
- 2.0 - Installing the software -A) - To install the software unzip the file; the following screen will appear:
Ge3000 KIT
Ge3000
Ge3000
B) - Double-click on the Ge3000 icon; the screen of installation will appear. Follow the
instructions by clicking 'Ok' or 'Next' when required.
Ge3000
Ge3000
Ge3000
Ge3000
Ge3000
Ge3000
Ge3000
Ge3000
GE 3000
F) - NOTE If the system requires the installation of Framework.NET, click on the 'Yes' button
- 3.0 - Connection Setup A) - The software will add an icon on the desktop as indicated below. The first digit
indicates the hardware version of the Ge3000 c,ontroller; the others 2 digits indicate the
software release. In this example: version of hardware is '1' and version of software is
'12'. Connect the PC to Ge3000 (see section 8.00)
GE-ONE
GE3000-1.12
Ge3000
GE3000-4.0
B) - Double Click on the 'GE3000-1.12' icon (or choose 'Open' by using the mouse); the
main screen of the software will appear as indicated below.
Ge3000v1.14
GE3000
Ge3000
TO match the node programmed into Ge3000 as described in section 10.0 of the OEM
manual). Push 'Connect'; the following message will indicate the status of the
connection:
- 4.0 - How to read parameters Double click on the 'Ge3000 icon in the 'Selection' area; the root of the parameters and
functions will appear (see below).
GE3000v1.14
Ge3000
'GE3000 icon
'Selection
Area'
Select 'OFF'
mode of
operation
Feedback area (response
from the Ge3000)
'Display
Area'
Click on 'Parameters'; the list of parameters will be indicated in the 'Selection Area'. Click
on the Menu of your interest; the 'Display Area' will update automatically. You can read the
settings of Parameters, view Measurements, Alarms & Memory Events and other
functions. Three examples of screens follow. You can read the parameters always, but it is
possible to modify them only in 'OFF' mode (see sections 5.0 and 6.0).
Ge3000
GE3000
Ge3000
GE3000
Ge3000 v1.14
GE3000
- 5.0 - How to Modify / Store Parameters Click on 'Parameters'; the list of parameters will be indicated in the 'Selection Area'. Click
on the Menu of your interest; the 'Display area' will update accordingly. Before modifying
parameters you are required to enter the OFF mode by clicking the 'OFF' button (the
engine will stop). You can also enter the OFF mode by using the OFF button on the front
panel of the controller. By using the mouse or keyboard, you can modify the settings. Click
on 'Write parameters'(*) and the message 'Write Ok' will appear after a few seconds in the
'Feedback Area'. We recommend that you save the parameters in a file as indicated in
section 7.0.
(*)NOTE: if Ge3000 is password protected, you are not allowed to program the
parameters. The Ge3000 will return the message 'Write fail' (see section 10,0)
The software features a set of 'Factory Programmed' parameters (so called Defaults). To
load the defaults, click the 'Default' button. The message 'Default Parameters Loaded' will
appear in the 'Feedback Area'.
The Default button loads default parameters in a buffer of the PC. To write the defaults into
Ge3000, use the Write parameter ,procedure described in section 5.
Note: writing parameters into Ge3000 is possible only if the controller is in OFF
mode. You can enter the OFF mode by using the pushbutton of the front panel or
directly, by clicking on the 'OFF' button (see 4.0)
(**)NOTE: if Ge3000 is password protected, or not in O FF mode, you are not allowed
to program the parameters. The Ge3000 will return an error message (see section
10,0 for password programming)
10
Ge-XX
GND
B
A
TR
8 27
Vdc
POWER
POWER ON
Yellow
TX Red
2 poles
FEMALE
pitch 5mm
D-SUB9
FEMALE
D-SUB9
MALE
RS232
RX Green
4 poles
FEMALE
pitch 3.81mm
GND
B
A
TR
RS485
INSTRUCTION OF USE:
4 poles
FEMALE
pitch 3.81mm
CABLE 2
(max 500M)
RS485
controller
CABLE 1
(max 6 M)
D-SUB9
FEMALE
D-SUB9
MALE
USB to
RS232
adapter
Computer
with RS232
Computer
with USB
adapter
D-SUB9
MALE
COM port
11
The area for the control of the Engine and Generator contains buttons that allows you to:
- open/close the contactor of the Generator (if Ge3000 is in manual mode)
- open/close the contactor of the Mains (if Ge3000 is in manual mode)
- acknowledge an alarm (only if you are in the 'Alarm status' page)
- select a mode of operation
- initiate a test cycle of the engine (only if the mode of operation is AUTO)
- terminate a test cycle of the engine (only if initiated by computer)
Indicates a
presence of
an alarm
Closes the
contactor of the
Mains
Opens a contactor
(Mains or Generator)
Closes the
contactor of the
Generator
Select the
mode of
operation
12
- 10.0 - OEM & USER Passwords Once connected, as described in section 3.0, the software controls if the Ge3000 is
password protected. If a OEM/USER password is programmed in the controller, the
software will display a red icon as indicated below.
It indicates that
Ge3000 has a User
password
It indicates that
Ge3000 has an OEM
password
GE3000
You can UN-LOCK the password (OEM,USER or both) by typing the 4 digit code. Ge3000
accepts numbers, Lower case and Upper case letters (case sensitive). After UN-LOCKING
the password(s), the icon(s) will appear as indicated in the next figure. Once UN-LOCKED
you are able to:
Disable the password
- click on the 'Disable' button. The 'Feedback Area' will provide you a confirmation of the
operation.
13
User password is
OEM password is
un-lock
un-lock
Ge3000 adress
- 11.0 - Control Panel & Miscellaneous To have access to the Control Panel, double click on Ge3000 and double click on
MISCELLANEOUS. The functions available are:
- control the dislay of the controller
- clear the Energy counter
- clear the starting counter
- cancel the memory
4-Buttons to control
the display of the
Ge3000
15