Sei sulla pagina 1di 30

LMT User Manual

MN028-03

Copyright Andrew Wireless Systems Srl

Andrew Wireless Systems Srl


Via Pier De Crescenzi 40
48018 Faenza, Italy
Tel: +39 0546 697111
Fax: +39 0546 682768
www.andrew.com

This publication is issued to provide outline information and is not aimed to


be part of any offer and contract.
The Company has a policy of continuous product development and
improvement and we therefore reserve the right to vary information quoted
without prior notice.
System and Customer care is available world-wide through our network of
Experts.
The company is certified ISO 9001 and ISO14000.

LMT User Manual

INDEX
1

INTRODUCTION

INSTALLING THE LMT SOFTWARE

USING LMT SOFTWARE

3.1

PROGRAM SETUP

3.2

QUICK CONFIGURATION

3.3

ADVANCED CONFIGURATION

14

3.3.1

Sub-Rack Discovery

15

3.3.2

TPRN Page

18

3.3.3

Master Optical TRX (TFLN) Page

21

3.3.4

Remote Unit Page

25

3.3.5

Utility

27

3.3.5.1 Debug Window

27

3.3.5.2 Configuration Files

28

3.3.5.3 Commissioning Files

29

SUPPORT

MN028-03

30

1 Introduction
This document describes installation and use of the LMT Software, which allows you to carry out a
proper commissioning of the ION-B system.
System requirements: Windows XP (SP1 or SP2), Me, 2000, 98, 95.
Minimum screen resolution 800 x 600. Standard RS-232 interface.

2 Installing the LMT Software


In order to install the LMT Software, please double click on the following icon.

The windows below will appear.

LMT User Manual

Press NEXT to start the LMT Software installation. The following window will appear, thus showing
the installation progress through the status-bar.

Once the installation process has finished, the following window appears:

MN028-03

After choosing FINISH , your Desktop will display this icon.


Double clicking on this icon, the program will be launched.

As an alternative, you can launch the LMT application either from the Program Menu or from the
Users Start Menu. In this latter case, the LMT application appears under an Andrew ION-B
submenu, which can include any other ION-B application installed in your system (e.g. Brite Tool).

LMT application, Windows XP Program Menu

Andrew ION-B window including the LMT application,


Windows XP User Menu

LMT User Manual

3 Using LMT Software


The LMT Software allows you to supervise an ION-B TPRN subrack, connected to your PC through
standard RS232 cable (provided with the TPRN subrack), as shown in the picture below.
If you have a multi-subrack system, the LMT software allows you to manage only one TPRN subrack
at a time, provided all the subracks have been connected one another through RS485 interface.
Please refer to ION-B User Manual for further information.

Laptop

TFLN

TPRNxx

TFAN

Figure 1: PC connection to use the LMT Software

The following steps need to be carried out in order to ensure the system works correctly:
1

Insert all the boards into the TPRN sub-rack and set different address into each TPRN (refer
to ION-B User manual for further information)

Connect all the Remote Units to the relevant Local Units;

Switch the remote units ON;

Switch the sub-rack ON;

Wait until the TFLN red leds stop blinking (Remote Unit discovery finished);

Connect the PC or laptop to the RS232 port of the TPRN sub-rack, using the RS232 cable
provided with the sub-rack. If your system has multiple TPRNs, please remember to connect
different TPRNs through
RS485 port, using the
LAN cable provided with
each TPRN subrack.

Run the LMT software


either from the LMT
application or from the
LMT icon on your
desktop.

The LMT wizard will open.

MN028-03

3.1 Program Setup


Press SYSTEM SETUP to check the setup parameters.

Be sure to choose the proper COM port of the PC or Laptop you are connected with.
Then press the SAVE&EXIT button in order to save the changes.

LMT User Manual

3.2 Quick Configuration


Click on QUICK CONFIGURATION to enter the page dedicated to the system commissioning, which
allows you to carry out a full scan of the elements installed in the system.
The following page will be presented.

Warning! Before doing any operation be sure to have completed sub-rack cabling and set different
addresses for all the sub-racks to avoid conflicts. Please refer to ION-B User Manual for
further information.

The whole Commissioning procedure consists of 4 steps:


STEP 1: select the range of TPRN addresses to scan.
Its strongly suggested that you scan addresses from 1 to 15, so as to assure that all the
TPRN subracks will be scanned.
Once chosen the address range, press START so as to launch the scanning process.

MN028-03

The status bar automatically notifies when the scanning process is complete, thus displaying the
number of the TPRN subracks which have been detected.

Warning:

10

if no sub-rack is found, check for the RS232 cable connection.

LMT User Manual

STEP 2: Once step 1 has been completed, please proceed with step 2.
Open the list of the TPRN subracks which have been detected, and choose the one you
want to commission. You will be provided with a list of discovered addresses, so as to
choose the TPRN address you want to commission (i.e. masking unused slots and
disabling unused receivers on TFLN Master Optical Trx).
Press START in order to discover all the modules inside the sub-rack. This procedure
has to be repeated for each TPRN subrack which has been detected.

The full information about the TPRN subrack to be scanned will be saved in the configuration file
BUS_MAP.CFG. The status bar will inform you as soon as this operation has been completed.

MN028-03

11

STEP 3:

Once step 2 has been completed, please proceed to step 3, which allows you to
mask the unused slots of the TPRN subrack and the unused Rx ports of the TFLN
Master optical Trx.
The Polling address window shows the TPRN subrack address which has been chosen
in step 2. Press MASK SLOT so as to mask the unused TPRN slots.
A message in the lower part of the STEP 3 window will notify you as soon as the TPRN
slots have been fully masked. Press MASK TFA so as to Mask the unused Trx ports.

12

LMT User Manual

UNMASK SLOT and UMMASK TFA allow you to restore the initial conditions.
STEP 4: By clicking on VIEW TPRN , a full description of the modules discovered inside the
TPRN subrack will be displayed.

Warning:

remember to repeat step 2 and 3 for all the TPRN addresses discovered in step 1.

Once you completed the commissioning steps, you can close the window and access the Advanced
Configuration menu so as to have more detailed information on the system.
MN028-03

13

3.3 Advanced Configuration


Click on ADVANCED CONFIGURATION to enter the page dedicated to a deeper overview of all the
boards. Remember that only one sub-rack and all its boards can be analysed at a time.
After clicking on ADVANCED CONFIGURATION , a page like the one below will be displayed, with
polling mechanisms already active.
If Quick Configuration has previously been performed, the Advanced Configuration page will display
the real status of the chosen sub-rack. If not, the Advanced configuration page will display the latest
subrack configuration which has been saved in the BUS-MAP.CFG file (see Quick Configuration,
Step 2).

14

LMT User Manual

3.3.1 Sub-Rack Discovery


In order to update the busmap file with the description of the boards housed in the subrack and the
installed Remote Units, the discovery process has to be activated.
First of all, press STOP POLLING in the Advanced Configuration page (see picture below).

The following page will be displayed. Select DISCOVERY from the toolbar

MN028-03

15

This page allows you to run a full scan (Discovery) of the TPRN subrack, thus including inserted
boards and connected Remote Units.

If you dont know the address of the TPRN to scan, press BUS SCANNING : a new window appears,
allowing you to choose the address range where TPRN subracks will be searched. After choosing
the range of addresses to search, press START. The toolbar below displays the TPRN address
detection.

16

LMT User Manual

Choose the TPRN address you want to scan, and press START DISCOVERY from the toolbar, so as
to let the discovery process start.

Once the discovery process has finished, a full description of all the system boards and the
discovered remote units is shown. Press START POLLING to come back to the TPRN page.

MN028-03

17

3.3.2 TPRN Page


After running the discovery process either from Quick Configuration or from the Advanced
Configuration menu, you can enter the TPRN page by clicking on the subrack links of the Advanced
Configuration page (see figure below).

This page consists of three sections:

ALARMS, where the TPRN alarm status is described;

STATUS, where the status of relays, power supply and bus is displayed;

TPR SLOTS, where all the active boards housed in the sub-rack are listed

To mask/unmask the unused TPRN slots, press CONFIGURATION , tick the slots you want to mask
and press OK . (see the window below)

In our example, lets suppose we want to extract the Local Units from slots 10 and 11, and mask
these slots. Slots 3, 6, 9 and 12 are already empty, and they have been automatically masked during
the system commissioning (Quick Configuration, step 3).
We therefore will tick the options general alarm slot 10 and general alarm slot 11, so as to disable
the alarm detection from revealing the empty slots 10 and 11, as shown in the pictures below.

18

LMT User Manual

If masking operations have been properly performed, the TPR SLOTS section will show the yellow
notice MASK next to each empty slot on the subrack.

MN028-03

19

Please refer to next paragraphs to learn how you can enter the TFLN pages, thus having access to
some more detailed information about Master Optical Trxs (TFLNs) and Remote Units.

Please note that the previous Subrack Configuration page allows you to change the alarm status and
the not-alarm status of the TPRN subrack auxiliary inputs (see ION-B User Manual for further
details), as well as to mask any TPRN alarm: it is strongly advisable, nevertheless, that this
operations are performed by a skilled user.

20

LMT User Manual

3.3.3 Master Optical TRX (TFLN) Page


By clicking on the Local Unit links in the TPR SLOTS section, you can enter the master optical Trx
(TFLN) page. (see pictures below).

MN028-03

21

This page consists of four sections:

ALARMS, where the TFLN alarm status is described;

STATUS, where the status of optical links towards the remote units is described;

ANALOG, where the detected analogue values are displayed;

GENERIC TFAN REMOTE BOARD/DEVICE, where all the Remote Units connected to the
TFLN are listed.

Select the left and right arrows on the screen to move upwards or downwards within each of these
sections.

22

LMT User Manual

To mask/unmask the unused TFLN ports, press DIGITAL COMMANDS , tick the Rx port you want to
disable.

Please note the Reboot command as well, on the top of the page, which allows you to reboot the
TPRN subrack.

By using the arrows in the Digital Commands section, you can control further options, such as:

TFA compatibility: you need to enable this option if your system includes some Standard
Britecell Remote Units. This way, any possible alarm due to communication mismatch from
older Britecell equipment will be avoided

DL laser shut down: it allows you to switch ON or OFF the laser of Master Optical Trx.

TFAxx discovery: you need to switch this option to Running if you want to run new a TFLN
discovery process, thus scanning the connected remote units without switching the subrack
OFF. Once this scanning has succeded, the flag will automatically switch back to
Completed

Automatic discovery mask: it enables or disables TFLNs automatic masking the Remote
Units at each system reboot. Once the system Commissioning has been performed, it is
strongly suggested to Disable this option.

MN028-03

23

Press OK to save changes and come back to the TFLN page.

Please refer to next paragraph to learn how you can enter the Remote Unit pages
From the TFLN page, press BACK to go back to the TRPN page.

24

LMT User Manual

3.3.4 Remote Unit Page


By clicking on the Remote Unit links at the bottom of TFLN pages, you can enter each Remote Unit
page.
The layout of the ALARMS section of a Remote Unit page depends on the remote unit type (Low
Medium, or High Power). Three examples of such layouts are shown in the pictures below.
ION-B Low Power Remote Unit

ION-B Medium Power Remote Unit

MN028-03

25

ION-B High Power Remote Unit

Each Remote Unit page consists of three sections:

ALARMS, where the Remote Unit alarm status is described;

STATUS, where the different statuses (if present) are described;

ANALOG, where the detected analogue values (if present) are highlighted;

Use the arrows to move towards the different sections.


By choosing DIGITAL COMMANDS , you will enter the page allowing you to mask the Rx ports of
the TFLN Master Optical Trx (so as to disable any alarm detection due to unused TFLN ports: see
picture below).

This page allows you to mask any other TFAx alarm: nevertheless, it is strongly suggested these
options are handled by a skilled user. To go back to the TFLN page, press BACK .

26

LMT User Manual

3.3.5 Utility
From the Advanced Configuration mode, its possible to access some utility allowing to:

debug the polling mechanism

access system files

access commissioning files

3.3.5.1 Debug Window


When working in LMT Advanced Configuration, the Debug Mode can be activated from each page
(TPRN, TFLN or Remote Unit) by choosing DEBUG WINDOW in the toolbar.

As an alternative, it can be activated by choosing GENERAL SETTINGS from the toolbar, then
DEBUG WINDOW.
Once the debug mode is activated, the following window will be shown. It displays the real-time byte
flow between your PC and the ION-B system.

MN028-03

27

3.3.5.2 Configuration Files


To enter the Configuration File menu, choose GENERAL SETTINGS from the LMT general menu,
then CONFIGURATION FILES .

The options of the Configuration Files menu are:

28

Device Types File: contains the list of all the devices supported by the LMT Software, with
relevant class, type and version codes.

LMT User Manual

Historical Alarms: contains the log file of all the alarms

3.3.5.3 Commissioning Files


To enter the Commissioning Files menu, choose GENERAL SETTINGS from the toolbar, then
COMMISSIONING FILES.

MN028-03

29

The options of the Commissioning Files menu are:

Write Busmap file: allows you to save the BUS_MAP.CFG file containing the latest
configuration of the system (see Quick Configuration, step 2)

Export CSV file: allows you to export a .csv file containing a full list of the devices actually
discovered in the system. A semicolon (;) will be used to separate each field from the
following ones.

4 Support
For further information or support about this product, please write to:
britecell@andrew.com