Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
PSS 2A-1F4 A
The Intelligent Temperature Transmitter receives input signals from RTDs, thermocouples, ohms sensors, or
dc mV sources, and transmits a linear 4 to 20 mA dc or FoxCom digital output signal. This microprocessorbased transmitter is available with HART or Foxboro digital communications protocol for remote communication
and database configuration from a hand-held terminal, personal computer, or I/A Series System.
4 to 20 mA, HART, or FoxCom Digital Output
Superior Accuracy
Long-Term Stability
Multiple Packaging Configurations offered,
including Pipe or Surface Mounting, DIN Rail
Mounting, Integral Bare Sensor, and Integral
Sensor with Thermowell
One Unit Configurable for all T/C, RTD, mV,
Ohm, and Dew Point Inputs. Custom Inputs can
also be accommodated.
Available as a Basic Unit, or in Aluminum or
316 ss Enclosure. Enclosure is Explosionproof
and meets NEMA 4X and IEC IP66.
PSS 2A-1F4 A
Page 2
GENERAL DESCRIPTION
REMOTE COMMUNICATIONS
BARE SENSOR
INPUT TYPES
This RTT20 Intelligent Temperature Transmitter can
be used with a wide variety of temperature sensors,
including two, three, and four-wire RTDs, all popular
thermocouples, and other resistance and millivolt
input devices. The following is a general list of transmitter input types:
Platinum RTDs
Nickel RTDs
Copper RTDs
Differential RTDs
Thermocouples
Millivolts
Ohms
Dew Point
Custom
BASIC
HOUSING
THERMOWELL
FOR PIPE
OR SURFACE
MOUNTING
PSS 2A-1F4 A
Page 3
LCD INDICATOR/CONFIGURATOR OPTIONS
These versatile one- and three-line Indicators plug
into the top of the transmitter (see Figure 2) and
provide the following features:
Local Configuration Both indicators have two
pushbuttons to rerange or reconfigure the
transmitter database without the use of a
separate configurator. Configuration menu
messages of the 3-line indicator are configurable
in English, French, German, or Spanish.
BASIC
TRANSMITTER
PLUG-IN
Highly Accurate The indicators are microprocessor driven, thereby eliminating any D/A
conversion error associated with the 4 to 20 mA
output signal.
Non-Interactive Transmitter output is
unaffected whether inserting or removing the
indicator, reading parameters, or downloading
data; or by indicator failure.
Portable A single indicator can be used for
multiple transmitters. No tools are required to
install or remove it. Simply plug it in, make
desired readings and/or adjustments to the
transmitter, unplug the indicator, and install it in
the next transmitter.
One Indicator The same indicator is used
regardless of transmitter output.
Custody Transfer/Security For Intelligent and
HART Output versions (Code -D or -T), the
configurator pushbuttons can be disabled via the
remote configurators.
Highly Visible Measurement Display 1-Line
Indicator has four 6 mm (0.25 in) high digits.
Corresponding top line of 3-Line Indicator has six
8 mm (0.31 in) high digits. Both indicators display
negative values with a minus sign.
Innovative 3-Line Indicator The second line of
this indicator is an eleven-segment bargraph that
displays readings in percent of calibrated range.
Temperatures outside the calibrated range are
indicated by a left-pointing (underrange) or rightpointing (overrange) arrow. The third line displays a user-configurable tag number on a 6 mm
(0.25 in) high, seven-character, alphanumeric
display. This line also automatically displays the
following fault messages:
FAILSAFE transmitter or sensor failure
D FAIL (Display FAIL) temperature exceeds
the limit of the display
The 1-Line Indicator displays sensor and
transmitter faults as FAILSAFE.
1-LINE, PLUG-IN
INDICATOR/CONFIGURATOR
WITH PUSHBUTTONS
3-LINE, PLUG-IN
INDICATOR/CONFIGURATOR
WITH PUSHBUTTONS
AUTOMATIC SELF-CALIBRATION
This transmitter has an advanced automatic selfcalibration routine that greatly extends the time
between recalibrations. Every three seconds, the
transmitter checks the zero and full scale output
against highly accurate and stable internal voltage
signals that are referenced back to the factory
calibration stored in non-volatile EEPROM memory.
Any necessary adjustments are made automatically
without interrupting the output signal.
NAMUR COMPLIANT FAILURE CURRENT
The transmitters current output is linear between 3.8
to 20.75 mA. But the failsafe current is adjustable
between 3.6 to 3.8 mA for a failsafe-low condition, or
from 20.75 to 23 mA for a failsafe-high condition. By
having the failsafe current different from the out-ofrange current, determining whether the transmitter is
in a failsafe condition, or just the process temperature
is beyond the calibrated range, is quick and easy
without the use of a configurator tool.
PSS 2A-1F4 A
Page 4
INSTALLATION ASSISTANT
Let Foxboro be your Installation Assistant. When you
order a transmitter with an integral sensor and
thermowell, everything is assembled, tagged, wired,
calibrated, and configured to your specifications. Just
open the shipping container and install. This feature
is ordered by specifying Model Code Package
Configuration Code L or M, along with Option
-D2. See Figure 3.
THERMOWELL
WITH EXTERNAL
THREAD SHOWN
EXPLOSIONPROOF UNION
RTT20 WITH
ALUMINUM
OR 316 ss
HOUSING
INSERTION
LENGTH
PSS 2A-1F4 A
Page 5
Influence
Ambient Temperature
Without Integral Display
With Integral Display
Relative Humidity
Supply Voltage
24 2C (75 3F)
24 2C (75 3F)
50 10%
30 0.5 V dc
Vibration
Negligible
PERFORMANCE SPECIFICATIONS
(Under Reference Operating Conditions Unless Otherwise Specified)
Accuracy
Refer to Table 1. The accuracy specification is
applicable merely by choosing a sensor type and
calibrated range without the need for any calibration
equipment.
Repeatability and Linearity
Included in accuracy.
Long-Term Stability
DIGITAL OUTPUT:
<0.05% of input reading (mV or ) per year
4 to 20 mA OUTPUT:
Digital Stability plus 0.043% of span per year.
Vibration Effect
<0.05% at 30 m/s2 (3 g)
PHYSICAL SPECIFICATIONS
Basic Transmitter (Package Code B)
Enclosed in polycarbonate material
Environmental Protection
Housing: NEMA 4X, IP66
Enclosure Construction
HOUSING (Package Codes S, W, L):
Epoxy-coated, low-copper aluminum
HOUSING (Package Codes T, Y, M):
316 ss (CF-8M/UNS-J92900)
HOUSING COVER O-RING
UV Stabilized Buna-N
Mounting Options
Option
Mounting
Set
DIN Rail
Code
-M1
-M2
-D1
Bracket
Hardware
Epoxy-Coated Steel
Stainless Steel
Aluminum and Plastic
Plated Steel
Stainless Steel
Plated Steel
PSS 2A-1F4 A
Page 6
FUNCTIONAL SPECIFICATIONS
Output Types
4 to 20 mA
Smart HART
Intelligent (4 to 20 mA or FoxCom Digital)
Output
RANGING:
Zero and span adjustment are non-interacting.
FAILSAFE (User-Configurable):
Downscale: 3.6 to 3.8 mA
Upscale: 20.75 to 23.0 mA
UNDERRANGE CURRENT: 3.8 mA
OVERRANGE CURRENT: 20.75 mA
ACTION: Direct or Reverse
Model
Code
See
Note
Pt100 DIN/IEC
Pt100 DIN/IEC
Pt100 SAMA
Ni 200
Ni 120, Minco
Ni 100
Cu 10
Q
A
P
D
G
I
F
c
d
e
f,n
n
g,n
h,n
Type B
Type C
Type E
Type J
Type K
Type L
Type N
Type R
Type S
Type T
Type U
B
C
E
J
K
L
N
R
S
T
U
k,r
k,p
k
k
k
m
k
k
k
k
m
Millivolt
Resistance
Dew Point
Custom
M
O
W
Z
n
n
Range Limits
C
Maximum Span
F
Digital Accuracy(b,q)
C
0.05
0.05
0.05
0.44
0.03
0.04
0.51
0.09
0.09
0.09
0.79
0.05
0.07
0.92
0.51
0.38
0.08
0.11
0.14
0.13
0.15
0.42
0.49
0.10
0.09
0.92
0.68
0.14
0.20
0.25
0.23
0.27
0.76
0.88
0.18
0.16
6 V
20 m
0.05C (0.09F)
PSS 2A-1F4 A
Page 7
Analog, 4 to 20 mA
Output Code -I
Intelligent FoxCom
Output Code -D
HART
Output Code -T
T/C Type B, C, E, J, K, L, N, R, S, T, U
RTD (2, 3, or 4 wire) 100 ohm DIN or SAMA
RTD (2, 3, or 4 wire) 100, 120, or 200 ohm nickel
RTD (2, 3, or 4 wire) 10 ohm copper
Millivolt
Ohms (2, 3, or 4 wire)
Dew Point
2 to 22 Point Custom Curve
YES
YES
NO
NO
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Tag Number
Tag Name
Location
Device Name
Message
OUTPUT
Output Type
Engineering Units (EGU)(1)
Burst Mode (HART Only)
Linearization Mode
INPUT
OTHER
PSS 2A-1F4 A
Page 8
FUNCTIONAL SPECIFICATIONS (Cont.)
Two-Wire Transmitter
The same two wires are used for input power, output
signal, and remote communication.
Turn On Time
TWO-WIRE SENSOR: 3.5 seconds
THREE- AND FOUR-WIRE SENSORS: 7 seconds
2490
RMAX = 83(VS - 12)
)
M
AX
(R
LO
AD
UM
Electronic Damping
4 to 20 mA VERSION:
1.2 seconds
INTELLIGENT VERSION:
Damping is configurable to settings of 0.25, 0.50,
1, 2, 4, 8, 16, and 32 seconds.
HART VERSION:
Damping is set as a floating decimal point value
between 0 and 32 seconds.
1500
AX
IM
1000
OUTPUT LOAD,
2000
500
OPERATING
AREA
NOTE 1
NOTE 2
0
0
10
20
30
12
SUPPLY VOLTAGE (VS), V dc
40
42
Input/Output
Isolation
Configurable
Input
Analog to Digital
Converter
Microprocessor
Sensor Type
Custom Curve
Engineering Units
Reranging
Failsafe
Loop Calibration
Output
4-20 mA (No Remote Comm)
4-20 mA HART
4-20 mA or FoxCom Digital
Temperature Compensation
Diagnostic Routines
Diagnostic Verification Timing
Self-Calibration Routines
Damping & Smart Smoothing
Communications
+
Nonvolatile Memory
Complete Configuration
Correction Coefficients
Factory Calibration Curves
1
2
3
4
Input
Multiplexer
Self-Calibration
Voltage Standards
Internal Cold
Junction
Digital-to-Analog Converter
(Not with FoxCom Digital)
Communication Modem
Conventional 4-20 mA Output: None
HART 4-20 mA Output: 220 Baud
Foxboro 4-20 mA Output: 600 Baud
FoxCom Digital Output: 4800 Baud
To Control
System
Remote Configurators
Foxboro Model HHT
Foxboro Model PC10
Foxboro Model PC20
HART Model 275
I/A Series System
PSS 2A-1F4 A
Page 9
Table 3. Electrical Safety Specifications
Testing Laboratory, Type of Protection, and
Area Classification
CENELEC intrinsically safe EEx ia, Gas
Group IIC, Zone 0.
CENELEC flameproof EEx d, Gas Group IIC,
Zone 1.
CSA intrinsically safe, Class I, Division 1,
Groups A, B, C, and D; Class II, Division 1,
Groups E, F, and G; and Class III, Division 1
hazardous locations.
CSA Class I, Division 2, Groups A, B, C,
and D hazardous locations.
CSA explosionproof, Class I, Division 1,
Groups B, C, and D; dust-ignitionproof,
Class II, Division 1, Groups E, F, and G: and
Class III, Division 1 hazardous locations.
CSA Class I, Division 2, Groups A, B, C, and
D hazardous locations.
CSA Class I, Division 2, Groups A, B, C, and
D hazardous locations.
FM intrinsically safe, Class I, Division 1,
Groups A, B, C, and D; Class II, Division 1,
Groups E, F, and G; and Class III, Division 1
hazardous locations.
FM nonincendive, Class I, II, and III, Division
2, Groups A, B, C, D, F and G hazardous
locations.
FM explosionproof, Class I, Division 1, Groups
B, C, and D: dust-ignitionproof, Class II,
Division 1, Groups E, F, and G; and Class III,
Division 1 hazardous locations.
FM nonincendive, Class I, II, and III,
Division 2, Groups A, B, C, D, F and G
hazardous locations.
FM nonincendive, Class I, II, and III,
Division 2, Groups A, B, C, D, F and G
hazardous locations.
KEMA European nonsparking/nonincendive
N, Gas Group IIC, Zone 2.
SAA intrinsically safe Ex ia, Gas Group IIC,
Zone 0.
SAA flameproof Ex d, Gas Group IIC, Zone 1.
SAA nonsparking Ex n, Gas Group IIC,
Zone 2.
Application Conditions
Electrical
Safety Code
EA
ED
CA
CD
CN
FA
FD
See Note (a)
FN
KN
AA
AD
AN
(a) The Factory Mutual (FM) approval of the Model RTT20 for the explosionproof rating listed above included pressure piling tests with
various lengths of conduit to ensure that conduit seals per NEC 501-5(a)1 within 475 mm (18 inches) of the housing are NOT required.
NOTES
1. The RTT20 Transmitter has been designed to meet the Electrical Safety descriptions listed above.
For detailed information, or status of testing laboratory approvals or certification, contact Foxboro.
2. Not all Electrical Specifications apply to all package configurations. Refer to the Model Codes section
that follows for codes applicable to each package configuration.
PSS 2A-1F4 A
Page 10
MODEL CODES
Model Code Basic, Surface, or Pipe Mount Transmitter Remote Sensors not provided with these Transmitters
Description
I/A Series Intelligent Temperature Transmitter
Output Signal and Communication Protocol
4 to 20 mA only; no Remote Communication (a)
4 to 20 mA or FoxCom Digital Communication (b)
4 to 20 mA with HART Communication (c)
Model
RTT20
I
D
T
Input Configuration
Single Input Channel
B
S
T
Sensor Length
None (Not Applicable to Transmitters with Remote Mounted Sensors)
X
B
C
E
J
K
L
N
R
S
T
U
Q
A
P
D
G
I
F
M
O
W
Z
AA
AD
AN
CA
CD
CN
EA
ED
FA
FD
FN
KN
Optional Selections
Refer to Optional Selections Codes further in document
(a) With Output Code -I, transmitter adjustment and output reconfiguration is possible only via an LCD Indicator/Configurator (Optional
Selection -L1 or -L3) which is easily transportable between transmitters. Remote communication is not available.
(b)Remote configuration with Models PC10, PC20, and HHT; or I/A Series system.
(c)Remote configuration with HART Model 275 Configurator (Foxboro Model HT991), Model PC20, and/or Foxboro ABO991 software.
PSS 2A-1F4 A
Page 11
MODEL CODES (Cont.)
Model Code Transmitter with Bare Sensor Mount or with Thermowell Mount Integrally Mounted Sensors
Model
Description
I/A Series Intelligent Temperature Transmitter
RTT20
Output Signal and Communication Protocol (a)
4 to 20 mA only; no Remote Communication (a)
4 to 20 mA or FoxCom Digital Communication (b)
4 to 20 mA with HART Communication (c)
I
D
T
Input Configuration
Single Input Channel
Package Configuration and Housing Material (Integrally Mounted Sensor - Bare or in Thermowell)
Bare Sensor Mounted to Aluminum Housing; 1/2 NPT Conduit Threads (Explosionproof)
Bare Sensor Mounted to 316 ss Housing; 1/2 NPT Conduit Threads (Explosionproof)
Thermowell Mounted to Aluminum Housing; 1/2 NPT Conduit Threads (Explosionproof)
Thermowell Mounted to 316 ss Housing; 1/2 NPT Conduit Threads (Explosionproof)
W
Y
L
M
Sensor Length
2 in (50 mm)
2.5 in (64 mm)
3 in (76 mm)
3.5 in (89 mm)
4 in (102 mm)
4.5 in (114 mm)
5 in (127 mm)
5.5 in (140 mm)
6 in (152 mm)
7 in (178 mm)
8 in (203 m)
9 in (229 mm)
10 in (254 mm)
11 in (279 mm)
12 in (305 mm)
18 in (457 mm)
24 in (610 mm)
30 in (762 mm)
36 in (914 mm)
Custom Length per Sales Order 120 in (3 m) maximum
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
U
V
X
E
J
K
T
Q
A
P
AA
AD
AN
CA
CD
CN
EA
FA
FD
FN
KN
Optional Selections
Refer to Optional Selection Codes further in document
(a) With Output Code -I, transmitter adjustment and output reconfiguration is possible only via an LCD Indicator/Configurator (Optional
Selection -L1 or -L3) which is easily transportable between transmitters. Remote communications are not available.
(b)Remote configuration with Models PC10, PC20, and HHT; or I/A Series system.
(c)Remote configuration with HART Model 175 Configurator (Foxboro Model HT991), Model PC20, and on Foxboro ABU991 software.
(d)Not available with Package Codes W and Y; but available with Package Codes L and M when Option -D2 is selected.
PSS 2A-1F4 A
Page 12
MODEL CODES (Cont.)
Optional Selection Codes
Used with Package Configuration Code:
Option Description
Option
Code
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-A1
-A2
-A3
-C1
-C2
-C3
-D1
-D2
-D3
-D4
-D5
-H2
-K1
-K2
-K3
-L1
-L3
-M1
-M2
-S1
-S2
-S4
Custody Transfer Lock and Seal is standard construction with Electrical Safety Codes EA and ED.
PG 13.5 Conduit Thread only available with Electrical Safety Codes EA and ED. Also not available with Option -A3.
Not available with Electrical Safety Codes AD, CD, ED, or FD. Also not available with Option -A2.
Available with Output Code -D only. Transmitter digital output to be connected to FBM18, 39, 43, or 44.
Hardware only; DIN rail is provided by user.
Required selection with Electrical Safety Codes AD, CD, or FD when Package Code L or M is used.
The optional -D3 retrofit kit provides an adapter plate and hardware to substitute an RTT20 into installations currently using an
older type RTT10, 893, E93, and E94 Temperature Transmitter.
Not available with Electrical Safety Codes AD, CD, ED, or FD.
Not available with Electrical Safety Codes AD, CD, ED, or FD; nor with Optional Selection -H2.
Not available with Optional Selection -D5.
For mounting transmitter to surface, or DN 50 or 2-in pipe.
Two 2-wire RTDs in one sheath. Available with Output Codes -D and -T only, and with Sensor Input Types Q and P.
NOTE
For further information relating to options, accessories, and services available
with the RTT20 Temperature Transmitter, refer to PSS 2A-1Z9 F.
PSS 2A-1F4 A
Page 13
SUGGESTED RFQ SPECIFICATIONS
The manufacturer shall provide a microprocessor-based temperature transmitter with 4 to 20 mA or digital
output which is linear to the measured temperature as follows:
Electronics:
Sensors:
Self Calibration:
Span Rangeability:
Enclosure:
Electrical Classification:
Communications:
Configurators:
LCD Indicator:
Accuracy:
Model Code:
ORDERING INSTRUCTIONS
1. Model Number
2. Calibrated Range
3. Thermowell Part Number or Model, if required (See PSS 3-3C1 A)
4. Remote Configurator, if required
Models PC10 or PC20 (FoxCom)
Model HHT (FoxCom)
I/A Series System (FoxCom)
Model 275 (HART)
Foxboro ABO991 Software (HART)
5. Tag Information
PSS 2A-1F4 A
Page 14
DIMENSIONS NOMINAL
mm
in
NOTE: For additional details, refer to Dimensional Print (DP 020-460).
T/C/mV
55
2.2
J
J
4
2 +
54
2.1
46
1.8
BASIC UNIT
WITH 1-LINE INDICATOR
BASIC UNIT
WITHOUT INDICATOR
BASIC UNIT
WITH 3-LINE INDICATOR
54
2.1
22
0.9
DIN RAIL
(BY USER)
NEXT
NO
60
2.4
ENTER
YES
PSS 2A-1F4 A
Page 15
DIMENSIONS NOMINAL (Cont.)
mm
in
SURFACE OR PIPE MOUNT TRANSMITTER WITH REMOTE SENSOR (PACKAGE CODE "S OR T")
DN 50 OR
2 in PIPE
(BY USER)
71
2.8
HOUSING
MATERIAL
DIMENSION X (NOTE 1)
WITH
WITHOUT
INDICATOR INDICATOR
87
99
316 ss
3.4
3.9
87
112
ALUMINUM
3.4
4.4
109
4.3
119
4.7
NOTES
1. ALLOW 51 mm (2 in) CLEARANCE
FOR COVER REMOVAL.
2. EXTERNAL COVER LOCK AND
GROUND SCREW LOCATION FOR
ELECTRICAL CODES EA, ED, AND
KN OR OPTIONAL FEATURE -A1.
100
3.9
NOTE 2
OPTIONAL PIPE
MOUNTING SET
1/2 NPT
A + 35
1.38
25
1.0
25
1.0
U + 115
4.5
25
1.0
U + T + 115
4.5
T
25
1.0
NOTE:
A = ELEMENT INSERTION LENGTH
U = THERMOWELL INSERTION LENGTH
T = THERMOWELL LAGGING LENGTH
PSS 2A-1F4 A
Page 16
Device Types
Transmitter - AP
Transmitter - GP
Pressure
Transmitter - GP
Transmitter - DP
Transmitter - DP
Transmitter - P/T/Flow
Multivariable
Transmitter - P/T
Transmitter
Temperature
Transmitter
Transmitter
Mass
Transmitter
Flow
Transmitter
Transmitter
Magnetic
Transmitter
Flow
Transmitter
Vortex
Flanged/Wafer
Sanitary
Flow
ElectropH, ORP, ISE (6)
CC & R (6)
Chemical
Transmitters EC (6)
ElectropH, ORP, ISE (6)
CC & R (6)
Chemical
EC (6)
Analyzers
Transmitter
Buoyancy
Transmitter
Valves
Positioner
Models
IAP10 & 20
IGP10 & 20
IGP25/50
IDP10
IDP25/50
IMV30
IMV25
RTT20
RTT25
CFT10
CFT15
CFT30
IMT25
IMT25L
IMT96
83F/83W
83S
870ITPH
870ITCR
870ITEC
875PH
875CR
875EC
144LD
144LVD
SRD991
4-20 mA
Analog
2A-1C13 C
2A-1C13 C
N/A
2A-1C14 C
N/A
N/A
N/A
2A-1F4 A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1-8A1 D
1-8A2 E
6-1B1 B
6-3C1 B
6-3N2 A
6-3A1 E
6-3A1 B
6-3N1 C
N/A
N/A
EVE0106 A-(en)
4-20 mA
with FoxCom
2A-1C13 A
2A-1C13 A
2A-1CTBD/TBD
2A-1C14 A
2A-1CTBD/TBD
2A-1C15 A
2A-1C15 B
2A-1F4 A
N/A
1-2B3 C
N/A
N/A
1-6F5 A
1-6F6 A
1-6F8 A
1-8A1 E
1-8A2 D
6-1B1 B
6-3C1 B
6-3N2 A
N/A
N/A
N/A
EML0610 A-(en)
EML1610 A-(en)
EVE0105 A-(en)
4-20 mA
FOUNDATION
fieldbus
with HART
2A-1C13 B
2A-1C13 E
2A-1C13 B
2A-1C13 E
2A-1CTBD/TBD 2A-1CTBD/TBD
2A-1C14 B
2A-1C13 E
2A-1CTBD/TBD 2A-1CTBD/TBD
N/A
N/A
2A-1C15 B
2A-1C15 B
2A-1F4 A
N/A
N/A
2A-1F4 C
N/A
N/A
N/A
N/A
1-2B5 A
N/A
1-6F5 A
1-6F5 B
N/A
N/A
N/A
N/A
1-8A1 E
1-8A1 F
1-8A2 D
N/A
N/A
N/A
N/A
N/A
N/A
N/A
6-3A1 E
N/A
6-3A1 B
N/A
6-3N1 C
N/A
EML0160 A-(en)
N/A
EML1610 A-(en)
N/A
EVE0105 A-(en) EVE0105 A-(en)
Other
(1)(2)
(1)(2)
N/A
(1)(2)
N/A
(2)
(2)
(2)
(2)
N/A
(3)
N/A
N/A
N/A
N/A
(4)
(4)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
(5)
N/A= Field device not available in that protocol at time of printing. Refer to www.foxboro.com/measurement/pss.htm.
(1) For low power voltage output (1 to 5 V) pressure transmitter family, refer to PSS 2A-1C13 D.
(2) Options/Accessories: see PSS 2A-1Z9 E for Pressure and Multivariable Transmitters, and PSS 2A-1Z9 F for Temperature Transmitters.
(3) For Modbus protocol mass meter Model CFT15, refer to PSS 1-2B3 D.
(4) For pulse output vortex meter Model, refer to PSS 1-8A1 D (for 83F and 83W) or PSS 1-8A2 D (for 83S).
(5) For Profibus Pa protocol valve positioner Model SRD991, refer to PSS EVE0105 A-(en).
(6) ORP = Oxidation Reduction Potential; ISE = Ion Selective Electrode; CC = Contacting Conductivity;
EC = Electrodeless Conductivity; and R = Resistivity.
The Foxboro Company
33 Commercial Street
Foxboro, MA 02035-2099
United States of America
http://www.foxboro.com
Inside U.S.: 1-888-FOXBORO
(1-888-369-2676)
Outside U.S.: Contact your local
Foxboro representative.
Facsimile (508) 549-4492
Foxboro, FoxCom, and I/A Series are trademarks of The Foxboro Company.
Invensys is a trademark of Invensys plc.
FOUNDATION is a trademark of The Fieldbus Foundation.
HART is a trademark of Hart Communications Foundation.
Inconel is a trademark of Inco Alloys International, Inc.
All other brand names may be trademarks of their respective companies.
An Invensys company
MB 010
0701