Sei sulla pagina 1di 3

Annexure I:

Norms for Measurement of Built-up Area

S. No.
1

Particular

% Payable area

Built-up area of each floor (excluding, service duct, lift

100%

shaft, ducts & refuge area).


2

Refuge area

70%

Electrical duct (100% of slab casted only)

100%

Fire fighting duct (100% of slab casted only)

100%

Plumbing duct (100% of slab casted only)

100%

Lift machine room

100%

UG tank & OH water tank

0%

Paving up to 20

0%

Society office, Watchman cabin

100%

10

Servants toilet

100%

11

Meter Room Area

100%

12

Lift Wells

50%

13

Balcony

50%

14

Flower beds

50%

15

Voids/Chajja/Elevation features

0%

16

Double height areas (if height is more than 6.0m)

Owner
(Sign & Stamp)

Page 32 of 36

150%

Contractor
(Sign & Stamp)

Annexure II

Payment Stages

Sr. No.

Stages

% break up

On Completion of Foundation/Raft, soling PCC etc

9%

RCC column, Beam, Slab

56%

Retaining wall

3%

OHT , lift machine room & terrace parapets

5%

UG Tank

5%

Brickwork including fixing of door frames/ sub frames

7%

Internal Plaster to all specified areas

6%

External Plaster

6%

On completion & handing Over of the project

3%

Total

100%

Owner
(Sign & Stamp)

Page 33 of 36

Contractor
(Sign & Stamp)

Annexure III

Cement Consumption Norms:

Item
No.
1.
2.
3.

4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.

Cement
Consumption
9 bags
12 bags

Brief Description
P.C.C. 1:4:8
P.C.C. 1:3:6
Concrete (for reference only)

Per
100 cft
100 cft

M15

6.2Bags

M20

6.8Bags

M25

7.0Bags

Or as per Cum
design
Cum
Mix.
Cum

M30

7.4Bags

Cum

M35

8.0Bags

Cum

M40

8.2Bags

Cum

300mm wide channel in Podium


Basement
9 Brickwork in cm 1:6
9 Brickwork in cm 1:5
9 Brickwork in cm 1:4
6 Brickwork in cm 1:5
41/2 Brickwork in cm 1:4
Brick on edge 3 thk. (1:3 cm)
Block masonry 100mm thk. (1:5 cm)
Block masonry 140mm (1:5 cm)
Block masonry 150mm (1:5 cm)
Block masonry 200mm (1:5 cm)
Siporex masonry 100mm (1:5 cm)
Siporex masonry 150mm (1:5 cm)
Siporex masonry 200mm (1:5 cm)
12mm thk. internal cement plaster to
slabs/beams, walls (1:4 cm)
thk. Backing coat plaster in C.M. 1:4
Sand faced plaster in 2 coats (20mm thk.)
Sand faced single coat plaster (20mm
thk.)
50mm thk. IPS Layer in M15 grade

0.9 bags
3 bags
3.75 bags
4.5 bags
2.5 bags
1.70 bags
1.70 bags
0.60 bag
0.75 bag
1.1 bag
1.5 bag
0.75 bag
0.75 bag
1.00 bags
1.5 bags

Rmt
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft
100 sft

1.5 bags
3.5 bags
2.0 bags
3.5 bags

100 sft
100 sft
100 sft
100 sft

Note: - Cement consumption for all concrete items shall be considered on the basis of Mix design
based on IS 456: 2000.

Owner
(Sign & Stamp)

Page 34 of 36

Contractor
(Sign & Stamp)

Potrebbero piacerti anche