Model F1FR 56 Sprinkler Types


Standard Upright
Standard Pendent
Conventional

Model F1FR 56 Recessed Sprinkler Types


Standard Pendent/F1/F2/FP

Model F1FR 56 Concealed Sprinkler Types

Upright

Pendent

Conventional

Recessed
Pendent/F1/F2

Recessed
Pendent/FP

Concealed Pendent

Standard Pendent

Listing & Approvals

1. Underwriters Laboratories Inc. and Certified for


Canada (cULus).
2. Factory Mutual Approvals (FM)
- Light Hazard - No Limitations
- Ordinary Hazard - Group 1 & 2, wet systems only.

3. Loss Prevention Council (LPCB, UK)


4. VdS Schadenverhtung GmbH

UL Listing Category

Sprinklers, Automatic & Open (VNIV)


Quick Response Sprinkler

Product Description

Reliable Models F1FR Series Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler.
The Models F1FR Series Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers
have demonstrated response times in laboratory tests
which are five to ten times faster than standard response
sprinklers. This quick response enables the Model F1FR
Series sprinklers to apply water to a fire much faster than
standard sprinklers of the same temperature rating.
The glass bulb consists of an accurately controlled
amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is
specially constructed to provide fast thermal response.
The balance of parts are made of brass, copper and beryllium nickel.
At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase
can be seen as a small bubble. As heat is applied, the
liquid expands, forcing the bubble smaller and smaller as
the liquid pressure increases. Continued heating forces
the liquid to push out against the bulb, causing the glass
to shatter, opening the waterway and allowing the deflector to distribute the discharging water.

Application

Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction.
Quick response sprinklers are intended for installation as
specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed.

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

Bulletin 014 Rev. C

Model F1FR Series


Quick Response
Standard Spray

Bulletin 156

Rev. B

Bulletin 156
Rev. B

Model F1FR 300


300 psi (20,7 bar) Rated
Quick Response
Sprinklers
Model F1FR-300
300 PSI (20,7 bar) Rated
Sprinkler Types
Upright
Pendent
Recessed Pendent
Upright

Listings & Approvals


1. Listed by Underwriters Laboratories, Inc. (UL)
2. UL Certified for Canada.
3. NYC MEA 258-93-E

UL Listing Category
Sprinklers, Automatic &Open
Quick Response Sprinklers

UL Guide Number
VNIV

Pendent

Product Description
Reliable Models F1FR 300 QR Upright, Pendent and
Recessed Pendent Sprinklers are high pressure rated
automatic sprinklers which can handle a maximum
service pressure of 300 psi (20,7 bar).
These automatic sprinklers are quick response
sprinklers which utilize a 3.0mm frangible glass bulb.
They have demonstrated response times in laboratory
tests which are five times faster than standard response
sprinklers. This quick response enables Model F1FR-300
sprinklers to apply water to a fire much faster than
standard response sprinklers of the same temperature
rating.
The glass bulb contains an accurately controlled
amount of special fluid hermetically sealed inside. The
other sprinkler parts are made of brass, copper or
beryllium nickel.
At normal temperatures, the glass bulb contains fluid
in both the liquid and vapor phases. The vapor phase
can be seen as a small bubble. As heat is applied, the
liquid expands, forcing the bubble smaller and smaller as
the liquid pressure increases. Continued heating forces
the liquid to push out against the bulb, causing the glass
to shatter, opening the waterway and allowing the
deflector to distribute the discharging water.
The temperature rating of the sprinkler is identified by
the color of the glass bulb.

Recessed Pendent

Application
The most common applications for Model F1FR-300
Quick Response Sprinklers will be in fire protection
systems for high rise buildings where a quick response
rating is required and the pressure entering the sprinkler
system is in excess of 175 psi (12 bar). The use of these
sprinklers will provide opportunity to reduce or eliminate
the need for pressure reducing valves.

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

Model F1FR-300 Quick Response Upright and Pendent Sprinkler


Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Sprinkler
Type

Upright

Pendent

Nominal
Orifice Size
"
(15mm)
17 "
32
(20mm)
"
(15mm)
17 "
32
(20mm)

Nominal K Factor
Thread Size

US

Metric

" NPT (R)

5.6

80

" NPT (R)

8.0

115

" NPT (R)

5.6

80

" NPT (R)

8.0

115

Sprinkler Height
2.2"
(56mm)
2.4"
(61mm)
2.2"
(56mm)
2.4"
(61mm)

Approval
Organizations

Sprinkler
Identification
Number (SIN)

1, 2, 3

R5625

1, 2, 3

R5622

1, 2, 3

R5615

1, 2, 3

R5612

Pendent

Upright

Model F1FR-300 Quick Response Recessed Pendent Sprinkler


Installation Wrench: Model GFR1 Sprinkler Wrench
Installation Data:
Sprinkler Nominal
Type
Orifice Size
Recessed
Pendent

"
(15mm)
17 "
32
(20mm)

Thread Size

Nominal K Factor
US
Metric

" NPT (R)

5.6

80

" NPT (R)

8.0

115

Sprinkler
Height
2.2"
(56mm)
2.4"
(61mm)

Escutcheon Data
Escutcheon Approvals Adjustment (1)
Model
F1
(1)

1, 2, 3

" (19mm)

Face of Fitting to
Ceiling Dimension
3 " 15
16 - 16 "
(5mm - 24mm)

When installed directly into a tee, the escutcheon


adjustment will be reduced.

2.

Approval
Organizations

Sprinkler Identification Number


(SIN)

1, 2, 3

R5615

1, 2, 3

R5612

(1)

Installation

Finishes

Quick response sprinklers are intended for installation


as specified in NFPA 13. Quick response sprinklers and
standard response sprinklers should not be intermixed.
The Model F1FR Recessed Quick Response
Sprinklers are to be installed as shown. The Model F1
escutcheon illustrated is the only recessed escutcheon to
be used with the Model F1FR-300 Sprinklers. The use of
any other recessed escutcheon will void all approvals
and negate all warranties.
When installing Model F1FR-300 Upright and Pendent
Sprinklers, use the Model D Sprinkler Wrench. Use the
Model GFR1 Wrench for installing F1FR-300 Recessed
Pendent Sprinklers. Any other type of wrench may
damage these sprinklers.
Glass bulb sprinklers have orange covers to
protect the bulb during the installation process.
REMOVE THIS PROTECTION ONLY AFTER THE
SYSTEM HAS BEEN HYDROSTATICALLY TESTED
AND, WHEN APPLICABLE, THE ESCUTCHEONS
HAVE BEEN INSTALLED. RASCO wrenches are
designed to install sprinklers when covers are in
place.

Standard Finishes:
Sprinkler
Escutcheon
Brass
Bronze
Chrome
Chrome
White Polyester Coated
White Painted
Special Application Finishes:
Sprinkler
Escutcheon
Bright Brass
Bright Brass
Black Plated
Black Plated
Black Paint
Black Paint
Off White
Off White
Satin Chrome
Satin Chrome
(1)

Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
6. Sprinkler Finish
7. Escutcheon Finish (where applicable)

Maintenance
Model F1FR-300 Sprinklers should be inspected
quarterly and the sprinkler system maintained in
accordance with NFPA 25. Do not clean sprinklers with
soap and water, ammonia or any other cleaning fluids.
Remove dust by using a soft brush or gentle vacuuming.
Remove any sprinkler that has been painted (other than
factory applied) or damaged in any way. A stock of
spare sprinklers should be maintained to allow quick
replacement of damaged or operated sprinklers. Prior to
installation, sprinklers should be maintained in the original
cartons and packaging until used to minimize the
potential for damage to sprinklers that would cause
improper operation or non-operation.

Note: When Model F1FR-300 Recessed sprinklers


are ordered, the sprinklers and escutcheons are
packaged separately.

Standard Temperature Ratings


Classification

Sprinkler
Temperature
F

Ordinary
Ordinary
Intermediate
Intermediate
High(1)
(1)

135

155
175
200
286

C
57
68
79
93
141

Other colors and finishes are available on special order.


Consult factory for details.

Maximum Ambient
Temp.
Bulb Color
F
C
Orange
38
100
Red
38
100
Yellow
66
150
Green
66
150
Blue
107
225

Not available for recessed sprinklers.

Sprinkler Types
Standard Upright
Standard Pendent
Recessed Pendent

3.

Reliable...For Complete Protection


Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.

Automatic sprinklers

Deluge valves

Flush automatic sprinklers

Detector check valves

Recessed automatic sprinklers

Check valves

Concealed automatic sprinklers

Supertrol electrical system

Adjustable automatic sprinklers

Sprinkler emergency cabinets

Dry automatic sprinklers

Sprinkler wrenches

Intermediate level sprinklers

Sprinkler escutcheons and guards

Open sprinklers

Inspectors test connections

Spray nozzles

Sight drains

Alarm valves

Ball drips and drum drips

Retard chambers

Control valve seals

Dry pipe valves

Air maintenance devices

Accelerators for dry pipe valves

Air compressors

Mechanical sprinkler alarms

Pressure gauges

Electrical sprinkler alarm switches

Identification signs

Water flow detectors

Fire department connections

The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual
Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.

Manufactured by

Recycled

The Reliable Automatic Sprinkler Co., Inc.


800.431.1588
Sales Offices
800.848.6051
Sales Fax
914.829.2042
Corporate Offices
www.reliablesprinker.com Internet Address

Paper

Revision lines indicate updated or new data.


E.G. Printed in USA 07/08 P/N 9999970163

Bulletin 165 Rev.C

Model GFR VELOECOH Upright


(SIN R6553)
Features
1. Provides Extended Coverage Ordinary
Hazard protection to 400 ft2 (37.2m2) per
sprinkler.
2. Very Extra Large Orifice of Nominal
K=14.0 (200) permiting low pressures.
3. 212F (100C) and 165F (74C)
temperature rating.
4. Available in brass, chrome, black plated
and polyester coated finishes.
5. Can be used for all editions of NFPA 13.
Listings & Approvals
1. Listed by Underwriters Laboratories, and UL
certified for Canada (cULus)
2. NYC MEA 258-93-E

Model GFR VELO-ECOH Upright

UL Listing Category

Design Criteria

Sprinklers, Automatic and Open Extended Coverage


Sprinklers Ordinary Hazard Occupancy

Reliable Model GFR VELO-ECOH sprinklers are to


be used in systems designed and installed in accordance with NFPA 13 and all other local codes and ordinances. The following design criteria also apply:
Minimum sprinkler spacing is 12 (3.6 m).
Sprinklers have a minimum flow requirement for each
spacing as shown in the Flow Requirements Table on
the reverse side.
ECOH sprinklers are only to be used in systems hydraulically designed per NFPA 13, and for a minimum
area of 1,500 ft2 (139.4 m2) or 5 sprinklers, whichever
is greater.
Deflector to commodity clearance shall be a minimum
of 18 (457mm).
ECOH sprinklers shall be installed in unobstructed
constructions as defined in NFPA 13. For open web
truss construction, web thickness is not to exceed 1
(25mm).
Sprinklers can be installed under a sloping ceiling not
exceeding 2 (50.8mm) of rise in 12 (305mm).
Maximum working pressure is 175 psi (12 bar) at the
sprinkler.

UL Guide Number
VNIV

Product Description
The Reliable Model VELO-ECOH Extended Coverage Sprinkler has a very extra large orifice, Nominal
K=14.0 (200). It can provide Ordinary Hazard protection to 400 ft2 (37.2 m2 ) at lower pressures than an XLO
which has a K=11.2 (160.2).
The Model GFR VELO-ECOH Sprinklers provide protection in Ordinary Hazard Group 1 and 2 Occupancies
to 400 ft2 (37.2m2) per sprinkler when the system is designed to NFPA 13 hydraulic density requirements.
Model GFR VELO-ECOH Upright Sprinklers are to be
installed according to the design criteria shown in this
bulletin. The use of ECOH sprinklers can provide opportunities for lower system installation costs by requiring fewer sprinklers, less piping and reduced labor.
Model GFR VELO-ECOH Sprinklers use a levered
fusible alloy solder link.

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523

Bulletin 165 Rev.C

Model GFR VELOECOH


Extended Coverage
Ordinary Hazard
Upright Sprinkler

Technical Data
Sprinkler
Model
GFR VELOECOH
Upright (1)
(1)

Thread
Size

Orifice
Size

NPT
(R)

0.70
(18mm)

Temperature
Rating

Max. Ambient
Temp.

165

74

100

38

212

100

150

66

Maximum
Sprinkler
Spacing

Maximum
Coverage
Area

20 ft.
(6.1 m)

400 ft.2
(37.2 m2)

Approvals

Sprinkler
Identification Number
(SIN)

1,2

R6553

Minimum Spacing Between GFR VELO-ECOH Upright Sprinklers is 12 feet (3.6m).

Minimum Flow Requirements


NFPA 13 - 1991 & Later
Ordinary Hazard 1
Spacing (1)

20 ft. x 20 ft.
(6.1m x 6.1m)
(1)

Coverage
Area

400 ft.
2
(37.2m )

0.15 gpm/ft2
2

NFPA 13 - 1989 & Earlier

Ordinary Hazard 2 Ordinary Hazard 1 Ordinary Hazard 2


0.20 gpm/ft2
2

(6.1L/min/m )
Density

0.16 gpm/ft2
2

(8.1 L/min/m )
Density

(6.5 L/min/m )
Density

0.19 gpm/ft2
2

(7.7 L/min/m )
Density

Ordinary Hazard 3
0.21 gpm/ft2
2

Nominal
K Factor

(8.25 L/min/m )
Density

Flow

Pressure

Flow

Pressure

Flow

Pressure

Flow

Pressure

Flow

Pressure

gpm
(L/min)

psi
(bar)

gpm
(L/min)

psi
(bar)

gpm
(L/min)

psi
(bar)

gpm
(L/min)

psi
(bar)

gpm
(L/min)

psi
(bar)

60.0
(227)

18.4
(1,3)

80.0
(302)

32.7
(2,3)

64.0
(242)

20.9
(1,5)

76.0
(287)

29.5
(2,1)

84.0
(318)

36.0
(2,5)

US

Metric

14

200

For spacing and coverage areas less than 20 ft. x 20 ft. (6.1m x 6.1m) and 400 ft2, the flows and
pressures for the 20 ft. x 20 ft. (6.1m x 6.1m) spacing and 400 ft2 (37.2m2) area must be used.

Maintenance
Model GFR VELO-ECOH Upright Extended Coverage Sprinklers should be inspected quarterly and the
sprinkler system maintained in accordance with NFPA
25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any
sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement
of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons
and packaging until used to minimize the potential for
damage to sprinklers that would cause improper operation or non-operation.

Ordering Information
Specify:
1. Sprinkler Model
2. Temperature Rating
3. Sprinkler Finish
Finishes(1)
Standard Finishes
Bronze
Chrome Plated
(1)

Other colors and finishes are available


on special order. Consult factory for
details.

Model H Sprinkler Wrench


Use Model H Wrench for Model GFR VELOECOH
Upright Sprinkler removal and installation.

Patents: U.S. Patent No. 6,446,732

The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual
Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the United States, Canada and foreign countries.

Manufactured by
Recycled
Paper

The Reliable Automatic Sprinkler Co., Inc.


(800) 431-1588
(800) 848-6051
(914) 829-2042
www.reliablesprinkler.com

Sales Offices
Sales Fax
Corporate Offices
Internet Address

Revision lines indicate updated or new data.


EG Printed in USA 9/03

P/N 9999970181

Model F1FR Quick Response Upright, Pendent & Conventional Sprinklers


Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal
Orifice

Thread
Size

Nominal K Factor
US

Metric

Sprinkler
Height

Approval
Organization

Sprinkler Identification Number


(SIN)
Upright

Pendent

Standard-Upright (SSU) and pendent Deflectors Marked to Indicate Position


(15mm)

NPT(R)

5.6

80

2.25 (57mm)

1, 2, 3, 4

RA1425 (1)

RA1414 (1) (2)

Conventional-Install in Upright or Pendent Position


15mm(1)
(1)
(2)

NPT(R)

5.6

80

57mm

3, 4

RA1475

cULus listed corrosion resistant (Polyester coated) sprinkler.


Polyester coated FM approved sprinkler.

Conventional

Pendent

Upright

Model F1FR 56 Quick Response Recessed Pendent Sprinkler


Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:

(1)

K Factor

Nominal
Orifice

Thread
Size

US

Metric

Sprinkler
Height

Sprinkler Identification Number


(SIN)

(15mm)

NPT(R)

5.6

80

2.25 (57mm)

RA1414

Refer to escutcheon data table for approvals and dimensions.

Model F1FR 56/F1 or F2

Model F1FR 56/FP

2.

Model F1FR Quick Response Concealed Pendent Sprinklers


Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
K Factor

Nominal
Orifice

US

(15mm)

Temp. Rating

Metric

Thread
Size

Model

5.6

80

NPT

(15mm)

5.6

80

(15mm)

5.6

(15mm)

5.6

(1)

Bulb
Color

Approvals

Sprinkler
Identification
Number(SIN)

1, 2

RA1414

Sprinkler

Cover

Max. Ambient Temp

F1FR

135F/57C

135F/57C

100F/38C

Orange

NPT

F1FR

155F/68C

135F/57C

100F/38C

Red

80

NPT

F1FR

175F/79C

165F/74C

100F/38C

80

NPT

F1FR

200F/93C

165F/74C

100F/38C

1, 2, 4

RA1414

Yellow

1, 2

RA1414

Green

1, 2

RA1414

(1)

For VdS only = 155F/68C Norbulb and 1/2 [12,7mm] adjustment.

Figure 2

Figure 1

Installation Aid

A protective cap is included for use during installation.


Important: The F1FR 56 Sprinkler with Model CCP cover
plate is not an FM Approved combination.

Sprinkler with a threaded Model CCP cup which is factory attached to the sprinkler. The assembly is completed by the installation of the attractive, low profile, 135F
(57C) or 165F (74C) rated Model CCP push on cover
plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible
tabs for threaded engagement. A choice of two cover
plate assemblies provide either (13mm) or 5/16 (8mm)
of cover adjustment.
Do not install these sprinklers in ceiling which have
positive pressure in the space above.
After a 25/8 (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1
Wrench. A Teflon* based thread sealant should be
applied to the sprinkler threads only. The Model RC1
Wrench is then used to engage the sprinkler wrenching
surfaces and to install the sprinkler in the fitting. When
inserting or removing the wrench from the sprinkler/cup
assembly, care should be taken to prevent damage to
the sprinkler. DO NOT WRENCH ON ANY OTHER PART
OF THE SPRINKLER. The cover plate is then pushed
onto the cup. Final adjustment is made by hand turning
the cover plate until the skirt flange makes full contact
with the ceiling. Cover plate removal requires turning in
the counter clockwise direction.

Installation

Quick response sprinklers are intended for installation


as specified in NFPA 13. Quick response sprinklers and
standard response sprinklers should not be intermixed.
The Model F1FR 56 Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons illustrated are the only recessed escutcheons
to be used with the Model F1FR 56 Sprinklers. The use
of any other recessed escutcheon will void all approvals
and negate all warranties.
When installing Model F1FR 56 Sprinklers, use the
Model D Sprinkler Wrench. Use the Model GFR2 Wrench
for installing F1FR 56 Recessed Pendent Sprinklers. Any
other type of wrench may damage these sprinklers.
NOTE: A leak tight NPT (R1/2) sprinkler joint can
be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m).
Do not tighten sprinklers over maximum recommended
torque. It may cause leakage or impairment of the sprinklers.
The Model F1FR 56/ CCP Concealed Sprinkler uses the
orifice, NPT (R1/2), 135F (57C), 155F (68C),
175F (79C) or 200F (93C) Model F1FR 56 Pendent
3.

After installation, inspect all sprinklers to ensure that there


is a gap between the cover plate and ceiling and that the
four cup slots are open and free from any air flow impediment to the space above.
Concealed cover plate/cup assemblies are listed only
for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR 56
Pendent Sprinkler or the use of the Model CCP Concealed
cover plate assembly on any sprinkler with which it is not
specifically listed my prevent good fire protection and will
void all guarantees, warranties, listings and approvals.
Glass bulb sprinklers have orange bulb protectors to
minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE
SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE
PROTECTION. Removal of the protectors before this time
may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in
place. REMOVE PROTECTORS BY UNDOING THE CLASP
BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS.

Temperature Ratings
Sprinkler
Max. Ambient
Classification Temperature
Bulb Color
Temp.
C
F
Ordinary
Ordinary
Intermediate
Intermediate
High (1)
(1)

57
68
79
93
141

135
155
175
200
286

100F (38C)
100F (38C)
150F (66C)
150F (66C)
225F (107C)

Orange
Red
Yellow
Green
Blue

Not available for recessed sprinklers.

Escutcheon Data
Escutcheon
Approvals
Model
F1

1, 3, 4

F2

1, 2, 3, 4,

FP Push-on/
Thread-off

1, 4

Adjustment

A
Dimension

Max Recess
Min Recess
Max Recess
Min Recess
Max Recessed
Min Recessed

1 (38.1mm)
34
/ (19.1mm)
1 (38.1mm)
1 (25mm)
7 16
/ (11mm)
15 16
/ (24mm)

Face of Fitting
to Ceiling or
Wall Dimension
3 16
/ - 15/16
(5mm - 24mm)
3 16
/ - 11/16
(5mm - 17mm)
11/2 (38.1mm)
1 (25.4mm)

Maintenance
The Models F1FR 56 and F1FR 56 Recessed Sprinklers
should be inspected quarterly and the sprinkler system
maintained in accordance with NFPA 25. Do not clean
sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle
vacuuming. Remove any sprinkler which has been painted
(other than factory applied) or damaged in any way. A stock
of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to

installation, sprinklers should be maintained in the original


cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or
non-operation.

Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Recessed Pendent
Finishes (1)
Sprinkler
Bronze
Chrome Plated
White Polyester
Coated (4)(5)

Standard Finishes
Escutcheon
Brass
Chrome
Plated
White Painted

Cover plate
Chrome
White

Special Application Finishes


Sprinkler
Escutcheon
Cover plate
Bright Brass (3)
Black Plated
Black Paint (2)
Off White (2)
Satin Chrome
(1)

(2)
(3)
(4)

(5)

Bright Brass
Black Plated
Black Paint
Off White
Satin Chrome

Bright Brass
Satin
Off White
Black Paint
Black Plated

Other finishes and colors are available on special order.


Consult the factory for details.
cULus Listed only.
200F (93C) maximum.
cULus listed corrosion resistance applies to SIN Numbers
RA1425 (Upright) and RA1414 (Pendent).
FM Approvals finish as Polyester coated applies to SIN Number
RA1414 (Pendent).

Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
6. Sprinkler Finish
7. Escutcheon Type
8. Escutcheon Finish (where
9. Cover plate Model
10. Cover plate Thread size
11. Cover plate Temperature
12. Cover plate Adjustment
13. Cover plate Finish

applicable)

Note: When Model F1FR 56 Recessed sprinklers are ordered, the


sprinklers and escutcheons are packaged separately.

The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Productsmanufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by

The Reliable Automatic Sprinkler Co., Inc.


(800) 431-1588
Sales Offices
(800) 848-6051
Sales Fax
(914) 829-2042
Corporate Offices
www.reliablesprinkler.com Internet Address

Recycled
Paper
Revision lines indicate updated or new data.
EG. Printed in U.S.A 12/09

P/N 9999970300

Potrebbero piacerti anche