THE small HOUSE CATALOG

PO BOX 434
Friday Harbor, WA 98250
www.thesmallhousecatalog.com
support@thesmallhousecatalog.com

LADDER HOUSE

DESIGN:
MAIN FLOOR AREA: 356 SQ FT
UPPER FLOOR AREA (EXCLUDING STAIRS): 260 SQ FT
FINISHED BASEMENT (EXCLUDING STAIRS): 175 SQ FT
TOTAL FINISHED/CONDITIONED AREA: 791 SQ FT
TOTAL ROOF AREA (INCLUDING PORCH AS SHOWN): 606 SQ FT

DESIGN STANDARDS:
INTERNATIONAL RESIDENTIAL CODE
ARCH D 24" X 36" BLACK & WHITE PRINTING

DESIGN FACTORS:
FIRST FLOOR LOAD: 40 PSF LIVE / 10 PSF DEAD
SECOND FLOOR LOAD: 30 PSF LIVE / 10 PSF DEAD
ROOF LOAD: 20 PSF LIVE / 10 PSF DEAD (IRC TABLE R802.5.1(2)

SPECIAL DESIGN REQUIREMENTS:


ENGINEERING MAY BE REQUIRED IN SEISMIC & HIGH WIND
ZONES. CONTACT YOUR LOCAL BUILDING DEPARTMENT FOR
INFORMATION. IN ADDITION, SPECIAL BUILDING
REQUIREMENTS MAY BE RECOMMENDED OR REQUIRED IN
COASTAL, RIPARIAN OR FIRE REGIONS. CHECK YOUR LOCAL
CODE ENFORCEMENT AGENCY FOR DETAILS.

DISCLAIMER & CONSTRUCTION WARNINGS

END USER AGREEMENT

CONSTRUCTION NOTES

1)THE SMALL HOUSE CATALOGHAS PREPARED THESE DOCUMENTS TO


MEET GENERALLY ACCEPTED PROFESSIONAL STANDARDS AND
PRACTICES. HOWEVER, THEY HAVE BEEN DESIGNED WITHOUT ANY
KNOWLEDGE OF OR REFERENCE TO THE LICENSEES SPECIFIC SITE
OR GEOGRAPHICAL LOCATION.SPECIFIC SITE CONDITIONS MAY VARY
AND INCLUDE BUT ARE NOT LIMITED TO SUCH THINGS AS: SUCH AS
FROST DEPTH, SOIL BEARING CAPACITY, SEISMIC AND WIND ZONES,
ETC.IN ADDITION, LOCAL CODE REQUIREMENTS, INCLUDING SUCH
LIFE-SAFETY REQUIREMENTS AS STAIR WIDTH, STAIR RISE AND RUN,
EGRESS WINDOWS AND SMOKE DETECTORS, ETC. MAY VARY.THE
S T R E N G T H O F M AT E R I A L S ( E . G . LU M B E R ) AVA I L A B L E M AY
VARY.THEREFORE,SUPPLEMENTAL TO THESE DOCUMENTS, IT IS THE
LICENSEES RESPONSIBILITY TO CONSULT WITH HIS/HER CHOSEN
BUILDER, LOCAL BUILDING DEPARTMENT ANDA STRUCTURAL
ENGINEER TO DETERMINE THAT THESE DOCUMENTS MEET ALL
CURRENT FEDERAL, STATE/PROVINCIAL AND LOCAL CODES,
ORDINANCES/BYL AWS AND REGUL ATIONS, ETC., AND ARE
APPROPRIATE TO SPECIFIC SITE CONDITIONS. COMPLIANCE WITH
SUCH REQUIREMENTS SHALL TAKE PRECEDENCE OVER THESE
DOCUMENTS.

1) THESE PLANS HAVE BEEN DESIGNED TO SATISFY GENERALLY


ACCEPTED BUILDING REQUIREMENTS. HOWEVER,THE SMALL HOUSE
CATALOGCANNOT GUARANTEE THAT THEY WILL BE APPROPRIATE FOR
YOUR SPECIFIC CONDITIONS OR THAT THEY WILL MEET ALL THE
REQUIREMENTS OF YOUR LOCAL CODING AGENCY. IT IS THE
RESPONSIBILIT Y OF THE LICENSEE TO SEE THAT THEY DO.
CONSULTATION WITH YOUR BUILDER PRIOR TO SUBMISSION OF A
PERMIT APPLICATION IS RECOMMENDED.

FASTENERS: FOR ALL PRESERVATIVE-TREATED & FIRE- RETARDANT


TREATED: CONNECTORS SHALL BE TREATMENT RATED. FASTENERS
SHALL BE HOT- DIPPED ZINC-COATED GALVANIZED, STAINLESS STEEL,
SILICON BRONZE OR COPPER. FOLLOW IRC TABLE R602.3(1) FASTENER
SCHEDULE FOR STRUCTURAL MEMBERS.

2) ANY USE OF THIS INFORMATION WITHOUT ADAPTATION TO


CHANGES IN CODES, STANDARDS, SITE CONDITIONS AND OTHER
FACTORS IS AT THE LICENSEES SOLE RISK.THE SMALL HOUSE
CATALOGASSUMES NO RESPONSIBILITY FOR CHANGES MADE TO
THESE PLANS BY OTHERS AND MAKES NO WARRANTIES, EITHER
EXPRESSED OR IMPLIED, IN THE USE OF THESE PLANS. THE LICENSEE
AG R E E S TO D E F E N D A N D I N D E M N I F Y T H E S M A L L H O U S E
CATALOGFOR ALL CLAIMS, COSTS, LOSSES OR DAMAGES RESULTING
FROM THE USE OF THESE DOCUMENTS.
3) BEFORE STARTING CONSTRUCTION , IT IS THE BUILDERS
RESPONSIBILITY TO CHECK ALL DIMENSIONS AND DETAILS, AND
VERIFY CONFORMANCE WITH GOVERNING CODE REQUIREMENTS
FOR THE GEOGRAPHIC AREA IN WHICH THE HOUSE IS TO BE BUILT. ALL
STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS SHALL
ALSO BE REVIEWED BEFORE CONSTRUCTION BEGINS. CODES GOVERN
OVER DRAWINGS AND DIMENSIONS GOVERN OVER SCALE. PLEASE
N OT I F Y T H E S M A L L H O U S E C ATA LO G O F D I M E N S I O N A L
DISCREPANCIES.
4)THE SMALL HOUSE CATALOGHAS NOT BEEN ENGAGED FOR
CONSTRUCTION SUPERVISION OF ANY KIND AND ASSUMES NO
RESPONSIBILITY TO ENSURE THAT CONSTRUCTION CONFORMS TO
THESE PLANS, NOR HAS ANY RESPONSIBILITY FOR CONSTRUCTION
MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES OR
SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK.

SITE PREPARATION: A SURFACE DRAINAGE PATTERN SHOULD BE


ESTABLISHED WHICH WILL DRAIN THE ENTIRE AREA AND DIRECT WATER
AWAY FROM THE HOUSE. THE FINISHED GRADE WILL BE SLOPED AWAY
FROM THE FOUNDATION WALL OF THE HOUSE.

2) THE SMALL HOUSE CATALOG INCLUDING ANYONE WHO HAS


BEEN INVOLVED IN THE CREATION, PRODUCTION, OR DELIVERY OF
THESE DOCUMENTS SHALL NOT BE LIABLE FOR ANY DIRECT,
INDIRECT, CONSEQUENTIAL, OR INCIDENTAL DAMAGES.

CONCRETE FOUNDATION: REMOVE ALL LOOSE & ORGANIC


MATERIALS & EXCAVATE FOR FOOTINGS & PADS AS PER PLANS. THE
DISTANCE OF THE FOOTING BASE TO THE FINISHED GRADE MUST BE
NO LESS THAN THE DEPTH OF LOCAL FROST PENETRATION. FOOTINGS
MUST BE ACCURATELY POSITIONED AND ROUGHLY LEVEL. FOOTINGS
VARY IN SIZE & DEPTH DEPENDING ON THE ALLOWABLE SOIL PRESSURE
AND THE LOAD. THE BOTTOM OF THE FOOTING IS ALWAYS PLACED ON
UNDISTURBED SOIL OR COMPACTED GRANULAR FILL WITH EACH RUN
LEVEL.

3) THE LICENSEE IS GRANTED LICENSE TO BUILD ONE HOUSE PER


PLAN. ADDITIONAL PRINTS MAY BE INDEPENDENTLY COPIED, AS
REQUIRED, TO BUILD YOUR HOUSE. ANY CHANGES TO THESE PLANS
MUST BE CONFIRMED BY A LICENSED STRUCTURAL ENGINEER AND
APPROVED BY YOUR LOCAL CODE ENFORCEMENT AGENCY.
4) ALL PLANS ARE PROTECTED BY FEDERAL COPYRIGHT LAWS. ANY USE
OF THE INFORMATION CONTAINED HEREIN BEYOND THE ONE-TIME
USE AUTHORIZED BY A PURCHASE OF PRINTS, OR ANY DUPLICATION,
PUBLICATION, SALE OR DISTRIBUTION OF ANY PART OF THESE PLANS
WITHOUT THE PRIOR WRITTEN CONSENT OF THE ORIGINAL DESIGNER
REPRESENTS A VIOLATION OF FEDERAL LAWS SUBJECT TO THE
PRESCRIBED PENALTIES.

WATERPROOFING: CONCRETE WALLS BELOW GRADE SHOULD BE


WATERPROOFED WITH A NON-TOXIC ELASTOMERIC MATERIAL APPLIED
ON THE EXTERIOR SURFACE FROM THE FOOTINGS TO THE FINISHED
GRADE LINE, TO MAKE THE WALL WATERTIGHT AGAINST ORDINARY
SEEPAGE THAT MAY OCCUR.
FRAMING: PRIOR TO SILL PLATE INSTALLATION, INSPECT CONCRETE
WORK CONDITION AND COMPARE ALL SITE DIMENSIONS WITH
FOUNDATION PLAN DIMENSIONS.

5) ANY USE OF THE PLANS, OR MODIFICATIONS OF THE PLANS, BY


PURCHASERS, BUILDERS OR OTHERS IS DONE AT THEIR OWN RISK.
LICENSEE SHOULD HAVE THE PLANS REVIEWED BY A LOCAL
PROFESSIONAL ARCHITECT OR ENGINEER BEFORE THE START OF
CONSTRUCTION. THE INFORMATION CONTAINED WITHIN THE
CONSTRUCTION DOCUMENTS IS INTENDED TO DEPICT DESIGN AND
BASIC CONSTRUCTION DETAILING. IT IS THE BUILDER'S RESPONSIBILITY
TO PROVIDE STANDARD CONSTRUCTION DETAILS AND PRACTICES
WHICH WILL RESULT IN A STRUCTURALLY SOUND AND
WEATHERPROOF FINISHED PRODUCT.

SILL ANCHOR: THE SILL PLATE SHOULD BE LEVELED CAREFULLY. IF THE


TOP OF THE FOUNDATION IS LEVEL, THE SILL PLATE MAY BE LAID ON
FOUNDATION WITH A CLOSED CELL FOAM GASKET OR OTHER AIRIMPERMEABLE MATERIAL IN BETWEEN, AND OF SAME WIDTH AS SILL
PLATE. SILL PLATES SHOULD BE PRESSURE TREATED 2x MATERIAL DF #2
OR BETTER & ANCHORED TO CONCRETE WALL WITH 5/8" ANCHOR
BOLTS EMBEDDED 7" MIN. IN CONCRETE & 2" MIN. ABOVE CONCRETE.
ANCHOR BOLT SHOULD BE PLACED 4'-0" o.c. MAX. APART AND 12"
FROM ENDS WITH TWO BOLTS MIN. PER SILL PLATE.

6) HOUSE PLANS ARE NON-REFUNDABLE.


7) TERMS AND CONDITIONS APPLY TO ALL PLANS.

FLOOR JOISTS: JOISTS ARE INSTALLED, LOCATED & SPACED


ACCORDING TO THE DESIGN. ANY JOISTS HAVING A SLIGHT BOW
EDGEWISE SHOULD BE PLACED WITH THE CROWN ON TOP. ALL JOISTS
TO HAVE A MINIMUM OF 1-1/2" BEARING AT SUPPORT. FLUSH FRAMED
JOISTS TO BE FASTENED TO BEAMS WITH FULLY NAILED JOIST
HANGERS. ALL FLOOR OPENINGS TO BE FRAMED WITH DOUBLE
TRIMMER JOIST AND DOUBLE HEADER JOIST. INSTALL DOUBLE JOIST
OR SOLID BLOCKING UNDER ALL FRAMED PARTITION WALLS. INSTALL
BLOCKING BETWEEN JOISTS TO TRANSFER CONCENTRATED LOADS TO
BEARING BELOW.

5) THIS IS NOT A SALE OF ORIGINAL DOCUMENTS.THE SMALL HOUSE


CATALOGRETAINS OWNERSHIP OF ALL ORIGINAL DOCUMENTS AND
ALL SUBSEQUENT COPIES (REGARDLESS OF FORMAT).
6) THE LICENSEE IS GRANTED THE RIGHT TO MAKE COPIES AS NEEDED
FOR THE CONSTRUCTION OF ONE (1) BUILDING PER PLAN PURCHASE
AND/OR FREE DOWNLOAD.THE SMALL HOUSE CATALOGREQUESTS
THAT YOU HONOR THIS COPYRIGHT POLICY. ADDITIONAL RIGHTS CAN
BE EASILY PURCHASED AT A REASONABLE PRICE FROMTHE SMALL
HOUSE CATALOGOFFICE.

PRODUCT QUALITY:
CONSIDER SPECIAL ORDERING FORMALDEHYDE-FREE PLYWOOD, ZEROVOC, NON-TOXIC & NON-CARCINOGENIC PAINTS & STAINS, CAULKS,
SEALANTS & ADHESIVES RECOMMENDED.
BUGS & PESTS:

7) TERMS AND CONDITIONS APPLY TO ALL PLANS.

NO BROAD SPECTRUM INSECTICIDES OR HERBICIDES TO BE APPLIED


BEFORE, DURING OR AFTER THE FOUNDATION WORK. APPLY TERMITE
SHIELDS ONLY, IF REQ'D. PROPERLY SCREEN VENTING & OPENINGS.

8) MAILING ADDRESS:

SHEETS

THE SMALL HOUSE CATALOG

A0. COVER SHEET


A1. GENERAL NOTES
A2. ELEVATIONS
A3. FLOOR PLANS
A4. BUILDING SECTION
A5. FOUNDATION PLAN & DETAIL
A6. FLOOR FRAMING
A7. ROOF PLAN & DETAIL
A8. INTERIOR VIEWS
A9. SCHEDULES

P.O. BOX 434


FRIDAY HARBOR, WA 98250
TEL. (360) 207-4513.
EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM
WEBSITE: WWW.THESMALLHOUSECATALOG.COM

E1. ELECTRICAL (BLANK)


P1. PLUMBING & MECHANICAL (BLANK)

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

GENERAL NOTES

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

01

IMPACT RESISTANT GLAZING, MIN. U-FACTOR .28

12

TEMPERED GLASS @ BATHROOMS

DECORATIVE EAVE BRACKETS, OPT.

12
4:12 PORCH

22'-2 1/2"
22'-2 1/2"

ADJ. STAIRS TO GRADE

6'-0"

14'-0"
20'-0"

8'-0"

14'-0"
22'-0"

FRONT ELEVATION
scale: 1/4"=1'

A
02

LEFT SIDE ELEVATION


scale: 1/4"=1'

B
02

STANDING SEAM METAL ROOFING


RECOMMENDED FOR SNOW

CEDAR SHINGLES OR
HARDISHINGLE (OR OTHER
CEMENTITIOUS SIDING)

22'-2 1/2"

22'-2 1/2"

14'-0"
BASEMENT EGRESS, REQ'D.

20'-0"

22'-0"

RIGHT SIDE ELEVATION


C
02

6'-0"

REAR ELEVATION

scale: 1/4"=1'

scale: 1/4"=1'

D
02

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

ELEVATIONS

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

02

FLOOR PLAN NOTES:


EGRESS:
1. ALL ROOMS TO BE USED FOR SLEEPING PURPOSES & BASEMENTS WITH
HABITABLE SPACE REQUIRE EMERGENCY & RESCUE OPENING COMPLYING WITH
IRC SEC R310.1.
2. AT LEAST ONE DOOR SHALL MEET EGRESS REQ. IRC R311. THIS DOOR MUST
BE SIDE HINGED WITH MIN. 32" (813 MM) CLEAR WIDTH WHEN MEASURED B/T
THE FACE OF THE DOOR & THE STOP W/ DOOR AT 90 DEGREES (1.57 RAD.).
MIN. CLEAR HEIGHT OF DOOR MUST NOT BE < THAN 78" (1981 MM) MEASURED
FROM TOP OF THRESHOLD TO BOTTOM OF STOP.

EGRESS WINDOW REQUIREMENTS:


1. MINIMUM 5.7 SQ. FT. NET CLEAR OPENABLE AREA, EXCEPT GRADE FLOOR
OPENINGS PERMIT MIN. 5 SQ. FT. OPENABLE AREA.
2. MINIMUM 24" NET CLEAR OPENABLE HEIGHT.

14'-0"

3. MINIMUM 20" NET CLEAR OPENABLE WIDTH.

5'-10 1/4"

20'-0"

4'-6 1/4"

3'-7 3/4"

3'-0"

14'-0"

7'-0"

3'-0"

7'-0"

4'-9 1/2"

4'-5"

4'-9 1/2"

4. SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR.
5. OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM
WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE.
150 CFM FAN

CO

FASTENER SCHEDULE:

POCKET DOOR

6'-6"

8'-1 1/2"

2'-0"

8'-9"

22'-0"

22'-0"
11'-5 3/4"

B
04

10'-1 1/2"

6'-9"

BEDROOM

NOOK

3'-4 1/4"

3'-1"

13'-0"

3'-2"

SD

CLOSET

8'-8"

UP

ZERO CLEARANCE, D.V. GAS


OR LPG FIREPLACE

4'-0"

5'-8"
EGRESS

11'-10"

FIREPLACE

6'-9"

UP

3'-2"

4'-2 1/2"
4'-2"

3'-9"

7'-0"
6'-0"

14'-0"

BEDROOM

EGRESS

2. PROVIDE UL-2034 APPROVED CARBON MONOXIDE ALARMS OUTSIDE EACH


SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF EACH BEDROOM IN
ACCORDANCE WITH IRC R315.2 O

3'-0"

LANDING/
HALL

3'-0"

8'-10"
12'-0"

1. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH IRC R314.3.

3'-0"

WC

CO

4'-0"

20'-0"

13'-2 1/4"

SMOKE DETECTORS & CARBON MONOXIDE ALARMS:

22'-0"

2. PROPANE & SOLID FUEL BURNING FIREPLACES TO BE INSTALLED ACCORDING


TO MANUFACTURER'S INSTRUCTIONS.

W.H.

3'-2"

SD

SD

2'-8"

22'-0"

HALL

1. PROPANE & SOLID FUEL BURNING FIREPLACES INSTALLATION SHALL COMPLY


WITH IRC CHAP. 10

5'-3 1/2"

BATH

14'-8 1/2"

BATH

UTILITY

21'-0"

3'-5 1/2"

FAN

4'-0"

MINIMUM FIREPLACE REQUIREMENTS:

5'-6"

7'-3"

5'-0"

8'-0"

FAN

3'-6"

1. STAIRWAYS & STAIRWAY LANDINGS, HANDRAILS & ILLUMINATION SHALL


COMPLY WITH IRC SEC R311. GUARDS PER IRC SEC R312.

FAN

22'-0"

8'-9 3/4"

STAIRS:

2'-9 1/2"

CLOSET

4'-0"

1. HABITABLE ROOMS PER IRC SEC R304 FOR FLOOR AREA.

2'-7 1/2"

MINIMUM ROOM AREAS & CEILING HEIGHT:

13'-0"

1. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER SCHEDULE, TABLES R602.3


(1) THRU (5).

BLOCKING:

WINDOW WELL FOR BASEMENT EGRESS

5'-0"

1. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF FLOOR, CEILING &


ROOF SYSTEMS AS PER IRC SEC R502, R802, IBC SEC 2308.8.2 & R2308.10.6.

5'-6"

14'-0"

3'-6"

7'-0"

7'-0"

14'-0"

BRACED WALLS:

14'-0"

FOLLOW IRC R602.10.3 & LOCAL CODE REQ'S.

FINISHED BASEMENT FLOOR


PLAN
A
03

A
04

1. WATER EFFICIENCY STANDARDS FOR PLUMBING FIXTURES SHALL BE MAX. 1.6


GAL PER FLUSH & 2.5 GAL PER MINUTE FOR SHOWER HEADS, LAVATORY
FAUCETS AND KITCHEN FAUCETS.

A
04

A
04

WATER EFFICIENCY:

scale: 1/4"=1'

MAIN FLOOR PLAN


B
03

UPPER FLOOR PLAN

scale: 1/4"=1'

C
03

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

FLOOR PLANS

scale: 1/4"=1'

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

03

STANDING SEAM METAL ROOF


30# FELT OR SYNTHETIC ROOF UNDERLAYMENT
-IN CDX SHEATHING
ROOF TRUSSES @ 24-IN O.C.
MIN. R-60 ATTIC INSULATION
" GWB OR WOOD PANEL CEILING
NON-TOXIC, ZERO-VOC LATEX PAINT OR STAIN

BUILDING NOTES:
ROOF SYSTEM:
STANDING SEAM METAL ROOF
30# FELT OR SYNTHETIC ROOF UNDERLAYMENT
-IN CDX SHEATHING
ROOF TRUSSES @ 24-IN O.C.
MIN. R-60 ATTIC INSULATION
" GWB OR WOOD PANEL CEILING
NON-TOXIC, ZERO-VOC LATEX PAINT OR STAIN

WALL SYSTEM:
NATURAL OR CEMENTITIOUS SHINGLES, STAINED
OR PAINTED
-" RAINS CREEN RECOMMENDED
15# FELT OR HOUSE-WRAP
" CDX SHEATHING
2X6 STUDS @ 24-IN O.C. W/MIN. R-30
SPRAYFOAM INSULATION
2X6 INSULATED HEADERS
-" GWB
NON-TOXIC, ZERO-VOC LATEX PAINT

NATURAL OR CEMENTITIOUS SHINGLES, STAINED OR PAINTED


-" RAINS CREEN RECOMMENDED
15# FELT OR HOUSE-WRAP
" CDX SHEATHING
2X6 STUDS @ 24-IN O.C. W/MIN. R-30 SPRAYFOAM INSULATION
2X6 INSULATED HEADERS
-" GWB
NON-TOXIC, ZERO-VOC LATEX PAINT

8'-1"

UPPER FLOOR SYSTEM:

" HARDWOOD FLOOR


TILE @ BATHROOMS, TYP.
" STURD-I-FLOOR
12-IN ENGINEERED FLOOR JOISTS @ 24" 0.C., TYP.
MIN. R-30 SPRAYFOAM @ RIM JOISTS
BATT INSULATION B/T JOISTS FOR SOUND OPT.
" GWB OR WOOD PANELING @ CEILING
NON-TOXIC, ZERO-VOC LATEX PAINT OR STAIN

" HARDWOOD FLOOR


TILE @ BATHROOMS, TYP.
" STURD-I-FLOOR
12-IN ENGINEERED FLOOR JOISTS @ 24" 0.C., TYP.
MIN. R-30 SPRAYFOAM @ RIM JOISTS
BATT INSULATION B/T JOISTS FOR SOUND OPT.
" GWB OR WOOD PANELING @ CEILING
NON-TOXIC, ZERO-VOC LATEX PAINT OR STAIN

3'-0"

ADJ. PORCH O/HANG TO OWNER SPECIFICATIONS

MAIN FLOOR SYSTEM:


" HARDWOOD FLOOR
TILE @ BATHROOMS, TYP.
" STURD-I-FLOOR
12-IN ENGINEERED FLOOR JOISTS @ 24" 0.C., TYP.
MIN. R-30 SPRAYFOAM @ RIM JOISTS
BATT INSULATION B/T JOISTS FOR SOUND OPT.
" GWB OR WOOD PANELING @ CEILING
NON-TOXIC, ZERO-VOC LATEX PAINT OR STAIN

FINISHED BASEMENT SYSTEM


2X4 INTERIOR WALLS
MIN. 3-" (R-24) POLYURETHANE SPRAYFOAM
INSUL.
" GWB
NON-TOXIC, ZERO-VOC LATEX PAINT

STAIR RISE: 7-"


STAIR RUN: 10"

EGRESS WINDOW

3'-2"

BASEMENT FOUNDATION:

12

8X12 CONT. CONC. FOOTERS


8-IN CONC. WALLS W/EXT. RIGID INSUL., CHECK
LOCAL CODES FOR INSUL. REQ'S.
4" CONCRETE SLAB W/6"X6" WELDED WIRE MESH
6 MIL POLY VAPOR BARRIER
MIN. R-40 RIGID SUB-SLAB INSULATION
4"-6" PEA GRAVEL UNDISTURBED SOIL OR
COMPACTED FILL

HEATING & A/C SYSTEM:

8'-1"

" HARDWOOD FLOOR


TILE @ BATHROOMS, TYP.
" STURD-I-FLOOR
12-IN ENGINEERED FLOOR JOISTS @ 24" 0.C., TYP.
MIN. R-30 SPRAYFOAM @ RIM JOISTS
BATT INSULATION B/T JOISTS FOR SOUND OPT.
" GWB OR WOOD PANELING @ CEILING
NON-TOXIC, ZERO-VOC LATEX PAINT OR STAIN

STAIR RISE: 7-"


STAIR RUN: 10

7'-8"

8'-0"
4

MIN. R-10 EXTERIOR RIGID INSUL. TYP.,


CHECK LOCAL CODES FOR REQ'S.

12

2X4 INTERIOR WALLS W/ 3-" (R-24)


POLYURETHANE SPRAYFOAM
INSULATION (USE 2X6 WALLS &
ADJUST INTERIOR DIMENSIONS FOR
ALT. INSULATION TYPES).

ZERO-CLEARANCE DIRECT-VENT NG OR LPG


FIREPLACE
ELECTRIC BACKUP HEATERS, OPT.

3'-6"

UPPER STAIRS WIDER TO


ALLOW HEADROOM O/
BASEMENT STAIRS

VENTILATION SYSTEM:

8"

EXHAUST FAN @ KITCHEN (150 CFM)


EXHAUST FAN BATHS & LAUNDRY (MIN. 80 CFM
OR CONNECTED TO HRV)
MIN. 5O CFM WHOLE HRV SYSTEM, CHECK
LOCAL CODES

EGRESS WINDOW

8-IN (R-40) POLYSTYRENE INSUL. BELOW SLAB

1'-4"
CROSS SECTION
A
04

scale: 1/2"=1'

INSUL. INT. WALL


NON-LOAD BEARING

B
04

scale: 1/4"=1'

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

REVISIONS

PARCEL NO.

CROSS SECTION

HOUSE CROSS SECTIONS

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

04

GENERAL FOUNDATION NOTES:

1. THE SILL PLATE SHOULD BE LEVELED CAREFULLY. IF THE


TOP OF THE FOUNDATION IS LEVEL, THE SILL PLATE MAY
BE LAID ON FOUNDATION WITH A CLOSED CELL FOAM
GASKET OR OTHER AIR-IMPERMEABLE MATERIAL IN
BETWEEN, AND OF SAME WIDTH AS SILL PLATE.
2. SILL PLATES SHOULD BE PRESSURE TREATED 2X
MATERIAL DF #2 OR BETTER & ANCHORED TO CONCRETE
WALL WITH 5/8" ANCHOR BOLTS EMBEDDED 7" MIN. IN
CONCRETE & 2" MIN. ABOVE CONCRETE. ANCHOR BOLT
SHOULD BE PLACED 4'-0" O.C. MAX. APART AND 12"
FROM ENDS WITH TWO BOLTS MIN. PER SILL PLATE.

" X 10" J-BOLTS W/5/8" WASHER


& NUT @ MAX. 48-IN O.C. AND W/
IN 12-IN OF CORNERS

8X16 CONT. CONC. FOOTING (CHECK


LOCAL CODE FOR FROST DEPTH REQ'S.)

8'-8"

12'-8"

8-IN CONC. COLUMNS W/4-#4 VERT. REBAR

3. PROVIDE APPROVED ANCHORAGE OF BEAMS OR


GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.
4. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER
SCHEDULE, TABLES R602.3 (1) THRU (5).

1'-4"

20'-8"

22'-0"

5. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF


FLOOR, CEILING & ROOF SYSTEMS PER IRC SEC'S R502 &
R802 & IBC SEC'S 2308.8.2 & 2308.10.6.
6. LUMBER SHALL BE PROTECTED AGAINST ROT & DECAY
PER IRC SEC R317.
7. FOR ALL PRESSURE PRESERVATIVE &
TREATED WOOD USE TREATMENT RATED
HOT-DIPPED GALVANIZED, STAINLESS
BRONZE OR COPPER FASTENERS PER IRC

EGRESS WINDOW W/EGRESS WELL,


CHECK LOCAL CODE FOR REQ'S.

FIRE-RETARDANT
CONNECTORS &
STEEL, SILICON
SEC R317.

8. MIN. 4" SLAB O/ POLY LAYER.


9. PROVIDE CRAWL SPACE ACCESS DOOR PER IRC 408.4
FOR CRAWL SPACES, WHERE APPLICABLE.
10. PROVIDE VENTILATION PER IRC R408.1 (1 SQ FT
OPENING PER 150 SQ FT FLOOR SPACE), WHERE
APPLICABLE.
11. R E F E R TO M A N U FAC T U R E R ' S I N S TA L L AT I O N
INSTRUCTIONS FOR ICF FOUNDATIONS.

BASEMENT PLAN (8' WALLS)


A
05

scale: 1/4"=1'

12. FOLLOW IRC R1001 FOR MASONRY FIREPLACES &


CONSULT W/ YOUR MASON TO FINALIZE THE DESIGN.
13. EGRESS WINDOW WELLS ARE REQUIRED WHERE THE
BOTTOM OF THE EGRESS WINDOW IS BELOW GROUND
LEVEL. THE EGRESS WELL MUST NOT INTERFERE WITH THE
EGRESS WINDOW FULLY OPENING. THE DISTANCE FROM
THE EGRESS WINDOW TO THE BACK OF THE EGRESS
WELL MUST BE AT LEAST 36 THE MINIMUM AREA OF THE
EGRESS WELL MUST BE 9 SQUARE FEET. (WIDTH X
PROJECTION)

METAL FLASHING INSUL. PROTECTION

GENERAL FRAMING NOTES:

SLOPE GROUND AWAY FROM FOUNDATION

MIN. 6"

1. NON-ENGINEERED JOISTS TO BE NO. 2 GRADE OR


BETTER
2.PROVIDE APPROVED ANCHORAGE OF BEAMS OR
GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.
3. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF
FLOOR, CEILING & ROOF SYSTEMS ACCORDING TO IRC
SEC'S 502 & R802, IBC SEC'S 2308.8.2 & R2308.10.6.
4. PROVIDE APPROVED ANCHORAGE OF BEAMS OR
GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.
5. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER
SCHEDULE, TABLES R602.3 (1) THRU (5).
6. ALL JOISTS DOUBLED @ FLOOR OPENINGS.
7. FOLLOW IRC TABLE R502.3.1(1) FOR JOIST SPANS OR
MANUFACTURERS SPECS FOR ENGINEERED JOISTS.

8-IN CONT. CONC. BASEMENT WALL W/2-#4 HOR. REBAR @ 24-IN O.C.

DRAIN ROCK

2X4 INTER. WALL W/ SPRAYFOAM INSUL.

POLYSTYRENE OR ROCKWOOL RIGID BOARD INSUL.


CHECK LOCAL CODES FOR REQ'S

GUTTER DRAIN TO STORM DRAIN OR SEWER

MIN. 4-IN SLAB W/WWM

6-MIL VB

4-IN PERFORATED PERIMITER DRAIN

8-IN (R-40) POLYSTYRENE SUBSLAB INSULATION


SAND OR PEA GRAVEL
8X16 CONT. CONC. FOOTER W/
2-#4 HOR. REBAR, CONT.

UNDISTURBED OR COMPACTED EARTH

INTERIOR BASEMENT DRAIN


BASEMENT WALL DETAIL
B
05

scale: 1"=1'

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

REVISIONS

PARCEL NO.

FOUNDATION PLAN & DETAIL

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

05

GENERAL FRAMING NOTES:


1. NON-ENGINEERED JOISTS TO BE NO. 2 GRADE OR
BETTER
2.PROVIDE APPROVED ANCHORAGE OF BEAMS OR
GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.
3. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF
FLOOR, CEILING & ROOF SYSTEMS ACCORDING TO IRC
SEC'S 502 & R802, IBC SEC'S 2308.8.2 & R2308.10.6.
4. PROVIDE APPROVED ANCHORAGE OF BEAMS OR
GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.
5. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER
SCHEDULE, TABLES R602.3 (1) THRU (5).
6. ALL JOISTS DOUBLED @ FLOOR OPENINGS.
4X12 LAMINATED BEAM SUPPORTED BY BASEMENT WALL OR POSTS

7. FOLLOW IRC TABLE R502.3.1(1) FOR JOIST SPANS OR


MANUFACTURERS SPECS FOR ENGINEERED JOISTS.

4X12 LAMINATED BEAM SUPPORTED BY WALL BELOW AND/OR POSTS

14'-0"

14'-0"

5'-5 3/4"

5'-5 3/4"

4'-1/2"

4'-1/2"

12'-4"

22'-0"

12'-4"

4'-2 1/4"

4'-2 1/4"

MAIN FLOOR FRAMING


A
06

scale: 1/4"=1'

22'-0"

UPPER FLOOR FRAMING


B
06

scale: 1/4"=1'

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

FLOOR FRAMING PLANS

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

06

ENGINEERED ROOF TRUSS 24-IN O.C. TYP.

ROOF FRAMING NOTES:


EAVE BRACKETS, OPT.

1. NUMBER FO JACK STUDS FOR ALL GIRDER & HEADER


SPANS PER IRC TABLE R502.5 (1) & (2) - FOOTNOTE 'D'.
2. POSITIVE CONNECTION & TRANSFER OF LOAD FROM
ROOF TO LOAD SUPPORTING ELEMENTS REQ'D.
3. PROVIDE ANCHORAGE OF BEAMS OR GIRDERS TO
POSTS PER IRC SEC'S R407.3, R502.9 & R802.11
4. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER
SCHEDULE, IRC TABLES R602.3 (1) THRU (5).
5. SOLID BLOCKING REQ'D @ ALL BEARING POINTS OF
FLOOR, CEILING & ROOF SYSTEMS ACCORDING TO IRC
SEC'S R502 & R802.

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

6. ATTIC VENTILATION PER IRC SEC R806.

GENERAL FRAMING NOTES:


1. JOISTS TO BE NO. 2 GRADE OR BETTER
2.PROVIDE APPROVED ANCHORAGE OF BEAMS OR
GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.

2'-0"
TRUSS CLIPS @ EACH BEARING TRUSS OR PER
MANUFACTURER'S RECOMMENDATION

3. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF


FLOOR, CEILING & ROOF SYSTEMS ACCORDING TO IRC
SEC'S 502 & R802, IBC SEC'S 2308.8.2 & R2308.10.6.

ROOF PLAN
A
07

4. PROVIDE APPROVED ANCHORAGE OF BEAMS OR


GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.

scale: 1/4"=1'

5. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER


SCHEDULE, TABLES R602.3 (1) THRU (5).
6. ALL JOISTS DOUBLED @ FLOOR OPENINGS.
7. FOLLOW IRC TABLE R502.3.1(1) FOR JOIST SPANS.

ALTERNATIVE STYLE TRUSSES MAY BE USED, VERIFY W/MANUFACTURER;


FOLLOW MANUFACTURER'S INSTALLTION INSTRUCTIONS.

MAX. O/HANG MEASURED FROM


EXTERIOR BEARING POINT OF TRUSS

2'-0

12

"

STRONG-TIE DTC TRUSS CLIPS @ EACH TRUSS

TRUSS ELEVATION
B
07

scale: 1/2"=1'

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

ROOF FRAMING PLAN & DETAILS

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

07

STANRD 36-IN REFRIGERATOR

VENTILATION CHASE

1'-1"

STAIRS TO BASEMENT

LOAD BEARING WALL OR POSTS, OPT.

150 CFM EXHAUST FAN

2'-6"
CUTTING BLOCK AREA

SINK

8'-1"

8'-1"
1'-6"

SEATING @ FLIP SIDE OF KITCHEN

3'-0"
STANDARD 24" DISHWASHER

1'-6"
2'-6"

2'-6"

2'-11 3/4"

2"

3"

4'-4"

1'6"

2'-8"

13'-0"

3'-0"

2'-0"

13'-0"

STANDARD GAS RANGE

IKEA STYLE ISLAND W/ SINK & SEATING

KITCHEN VIEWS
A
08

scale: 1"=1'

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

INTERIOR VIEWS

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

08

9'-0"

2'-0"

3'-0"

3'-0"

3'-0"

2'-0"

2'-0"

2'-0"

4'-0"

2'-0"
C

2'-0"

2'-0"

2'-0"
C

2'-0"
C

2'-0"
C

2'-0"

6'-0"
2'-0"

3'-0"

2'-0"
2'-0"

2'-0"
C

6'-8"
A

3'-0"

2'-0"

2'-0"
4'-6"

4'-6"

3'-0"

2'-0"

2'-0"

2'-10"

4'-6"

6'-0"

2'-0"

6'-8"

H
F

3'-0"

3'-0"

4'-0"

1
I

BASEMENT WINDOW PARTIALLY SHOWN;


CHECK LOCAL REQ'S FOR WELL SIZING

FENESTRATION
scale: 1/4"=1'

A
09

WINDOW SCHEDULE
SIZE

STYLE

NO.

6'-0" X 4'-6"

DOUBLE CASEMENT OR DBL HUNG

9'-0" X 3'-0"

TRIPLE CASEMENT

2'-0" X 2'-0"

SINGLE CASEMENT

2'-0" X 3'-0"

CASEMENT OR DBL HUNG

3'-0" X 4'-0"

EGRESS CASEMENT

3'-0" X 4'-6"

SINGLE DBL HUNGS OR CASEMENTS

3'-0" X 2'-0"

FIXED

6'-0" X 2'-10"

DOUBLE CASEMENTS

3'-4" X 6'-0"

BASEMENT EGRESS

DOOR SCHEDULE
SIZE

STYLE

NO.

3'-0" X 6'-8"

ENTRY

3'-0" X 6'-8"

EXTERIOR MUDROOM DOORS

2'-6" X 6'-8"

INTERIOR
DOORS
TRIPLE ROOM
BIFOLDING

4
1

2'-6" X 6'-8"

POCKET DOOR (UPPER BATHROOM)

5
4

2'-6" X 6'-8"
3'-0"

BIFOLDING
HINGED
CLOSET
CLOSET
(BASEMENT)

4'-0" X 6'-8"

BIFOLDING CLOSET (UPPER BEDROOM)

WINDOWS & DOORS SHOULD BE BID TO THE CLOSEST OPERABLE STOCK UNIT SIZES TO AVOID CUSTOM SIZING COSTS. BE SURE TO BID FOR
EGRESS REQ'S WHERE REQ'D. TRIPLE GLZED, LOW U-FACTOR (MIN. U-.28) WINDOWS & DOORS ARE RECOMMENDED. FLOOR PLANS SHOULD
BE REFERENCED FOR INTERIOR DOOR LOCATIONS AND SWING DIRECTIONS. PLEASE VERIFY ALL WINDOE & DOOR INFORMATION WITH
OWNER PRIOR TO ORDERING. MARVIN INTEGRITY WINDOWS AND DOORS (OR SIMILAR) ARE SUGGESTED.

WINDOW & DOOR


SECHDULES
C
09

scale: 1/4"=1'

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

WINDOW & DOOR SCHEDULES

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

09

ELECTRICAL NOTES:
BEFORE YOU BEGIN:
IF YOU INTEND TO DO YOUR OWN ELECTRICAL WORK, IT IS
GOOD PRACTICE TO HIRE A CERTIFIED ELECTRICIAN TO
REVIEW THE PLAN BEFORE YOU BEGIN WORK, MAKE
NECESSARY CHANGES & CORRECTIONS, LOCATE YOUR PANEL
BOX & METER, SPECIFY WIRE GAUGES, AND REVIEW YOUR
WORK PRIOR TO INSPECTION.

OUTLETS:
1. ALL KITCHEN, BATHROOM, BASEMENT AND CRAWL SPACE
OUTLETS TO BE GFCI.
2. EXTERIOR OUTLETS TO BE WEATHER PROOF GFCI.
3. STANDARD OUTLETS TO BE TAMPER RESISTANT.
4. AFCI REQ'D ON ALL CIRCUITS SERVING LIVING AREAS.

WATER HEATER:
1. A 4-6 GPM ELECTRIC ON-DEMAND W.H. IS TYP. SUFFICIENT
EVEN IN NORTHERN CLIMATES TO ADEQUATELY SUPPLY THE
BATHTUB.
2. FOR ON-DEMAND PROPANE OR GAS W.H., PROVIDE
VENTILATION.

LAUNDRY ROOMS:
1. 110 CFM REQ'D IN LAUNDRY ROOM.
2. GFI OUTLETS

BATHROOMS:

COMMON RESIDENTIAL ELECTRICAL SYMBOLS

1. GFI OUTLETS ON DEDICATED CIRCUIT.


2. MIN. 110 CFM EXHAUST FAN REQ'D.

KITCHEN:
1. MIN. TWO OUTLET CIRCUITS.

DUPLEX POWER RECEPTACLE


DUPLEX POWER RECEPTACLE ON
DEDICATED CIRCUIT

240 OUTLET ON DEDICATED CIRCUIT


SWITCH

PORCHES:

THREE-WAY SWITCH

1. MIN. ONE WP-GFI PER PORCH.

D-240

3. NON-GFI REFRIGERATOR OUTLET.

240

240 OUTLET

GFIC/WP

GFI

DUPLEX POWER RECEPTACLE W/


GROUND FAULT INTERRUPTOR
CIRCUIT (WP = WEATHERPROOF)

2. GIF OUTLETS REQ'D.

4. 150 CFM EXHAUST FAN O/ RANGE.

$3

INT. WALL SCONCE

2. WP LIGHTS
INT. CEILING LIGHT

SMOKE DETECTORS:
1. EACH FLOOR (INCLUDING BASEMENT) TO HAVE A SMOKE
DETECTOR.

EXT. WALL SCONCE

W.R.

EXT. CEILING LIGHT

W.R.

2. ALL SLEEPING AREAS TO HAVE INDIVIDUAL SMOKE


DETECTORS.
3. PHOTOELECTRIC (NON-IONIZING) SMOKE DETECTORS ARE
RECOMMENDED.

CHANDELIER
SMOKE DETETCTOR
CARBON MONOXIDE DETECTOR

SD
CO

TELEPHONE OUTLET

4. CO2 DETECTORS REQ'D WHERE SOLID FUEL HEATING IS TO


BE USED.

DATA/CAT-6
TELEPHONE/CAT-6

5. SMOKE AND CO2 DETECTORS TO BE WIRED ON SEPARATE


CIRCUITS.

CABLE TV OUTLET

TV

GARBAGE DISPOSAL

GD

ELECTRICAL SERVICE PANEL


JUNCTION BOX (WITH WHIP)

ESP
J

DOOR BELL
WATER HEATER

WH

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

ELECTRICAL PLAN (INTENTIONALLY BLANK)

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

A
E 1/1
10

GENERAL PLUMBING NOTES:


THIS SCALED SHEET IS FOR AIDING YOU AND YOUR PLUMBER IN
LAYING OUT THE PLUMBING SYSTEM FOR YOUR HOUSE.
GENERAL INFORMATION ONLY. VERIFY WITH APPLICABLE
PLUMBING CODE (TYP. UPC), LOCAL CODE ENFORCEMENT, AND
MANUFACTURERS' RECOMMENDATIONS.

DRAIN, WASTE & VENT (DWV):


1. KITCHEN SINKS: DWV MIN. 2" DRAIN & 1 1/2" VENT.
2.BATHROOM SINKS: DWV MIN. 1 1/4 DRAIN & VENT.
3. BATHTUBS: MIN. 2" DRAIN & 1 1/2" VENT.
4. SHOWERS: MIN. 1 1/2" DRAIN & VENT.
5. INCOMING WATER SUPPLY LINE: TYP. 3/4" - 1"
6. PRIMARY WATER SUPPLY LINE: TYP. 3/4"
7. INTERIOR WATER SUPPLY LINES: TYP. 1/2"
8. MAIN DRAIN LINE: TYP. 3"
9. MAIN STACK VENT: TYP. EQUAL OR > THAN MAIN DWV LINE.

SUPPLY LINES (PEX OR COPPER, TYP.):


1. INCOMING SUPPLY LINE FROM STREET OR WELL: 1"
POLYPROPYLENE, COPPER OR PEX
2. MAIN HOUSE LINE (ROOM TO ROOM): 3/4" - 1'
3. BATHROOM SINK: 1/2"
4. TOILET: 3/8"
5. BATHTUB/SHOWER: 1/2"
6. KITCHEN SINK: 1/2"
7. WATER HEATER: 3/4"
8. WASHING MACHINE: 3/4"
8. SPIGOTS: 1/2" - 3/4"

REVISIONS

PARCEL NO.

REMARKS

MM/DD/YY

1
2
3

LADDER HOUSE

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

_ _ /_ _ /_ _

...

PLUMBING & HVAC PLAN SHEET (INTENTIONALLY BLANK)

A
P 1/1
11