Sei sulla pagina 1di 3

PT.

ASAHIMAS FLAT GLASS Tbk


HEAD OFFICE & FACTORY :
JL. ANCOL IX/5, ANCOL BARAT, JAKARTA, 14430, INDONESIA, PO BOX : 4344 / JKTF
PHONE : (62-21) - 6904041 (HUNTING)
FAX : (62-21) -6904128 (GENERAL) ; 6900470 (EXPORT) ; 6918709 (PROJECT & MARKETING);
6911928 (DOMESTIC) ; 6900716 (SAFETY GLASS)

TECHNICAL CHARACTERISTICS (SINGLE GLASS)


INDOFLOT
Type
Of
Glass

Indoflot
Clear
(FL)

Standard
Thickness
Transmittance
(mm)
(%)
2
85
3
84
4
81
5
78
6
76
8
70
10
67
12
62
15
60
19
54

Energy Characteristic
Reflectance
(%)
7
7
7
7
7
6
6
6
5
5

Light Characteristic
Ultra Violet
Absorption
Transmission Transmittance Reflectance
(%)
(%)
(%)
(%)
7
71
90
8
9
69
90
8
13
64
89
8
16
57
88
8
18
57
88
7
24
51
87
7
27
47
86
7
32
52
84
7
35
42
83
6
41
37
81
6

Solar
Factor
%

Shading
Coeficient
*3*4

U
Value
W/m2k

87
86
84
82
81
77
75
72
71
67

1.01
0.99
0.97
0.95
0.93
0.89
0.86
0.83
0.82
0.77

6.0
5.9
5.9
5.9
5.8
5.8
5.7
5.6
5.5
5.4

Solar
Factor
%

Shading
Coeficient
*3*4

U
Value
W/m2k

73
67
64
57
49
64
55
51
63
60
56
50
45
73
64
61
54
46
61
56
51
58
54
49
43

0.84
0.78
0.74
0.67
0.57
0.74
0.64
0.60
0.73
0.69
0.65
0.58
0.52
0.84
0.75
0.70
0.63
0.54
0.71
0.65
0.59
0.68
0.63
0.57
0.50

5.9
5.9
5.8
5.7
5.6
5.9
5.8
5.8
5.9
5.9
5.8
5.7
5.6
5.9
5.9
5.8
5.8
5.6
5.9
5.8
5.7
5.8
5.8
5.7
5.6

PANASAP
Type
Of
Glass

Panasap
Bronze
(BRFL)
Panasap
Dark Grey
(DGFL)
Panasap
Green
(GNFL)

Panasap
Euro Grey
(GEFL)
Panasap
Blue Green
(BNFL)
Panasap
Dark Blue
(DHFL)

Standard
Thickness
Transmittance
(mm)
(%)
4
64
5
55
6
51
8
41
12
28
3
51
5
38
6
33
4
49
5
45
6
39
8
30
12
21
3
64
5
52
6
46
8
36
12
23
5
47
6
39
8
31
5
43
6
36
8
29
12
19

Energy Characteristic
Reflectance
(%)
6
5
5
5
4
7
6
6
6
5
5
5
5
6
5
5
5
4
5
5
5
6
6
6
5

Light Characteristic
Ultra Violet
Absorption
Transmission Transmittance Reflectance
(%)
(%)
(%)
(%)
30
29
62
6
39
23
55
5
44
19
50
5
54
13
40
5
68
6
26
4
42
51
36
6
56
44
27
5
61
41
15
5
45
29
77
7
50
24
74
7
56
20
70
6
65
12
63
6
74
7
54
6
30
36
63
6
43
25
50
5
49
21
44
5
59
14
34
5
72
8
20
5
48
29
68
7
56
23
63
6
64
17
56
6
51
35
62
7
58
30
57
7
65
21
48
6
75
17
37
6

INDOFIGUR
Type
Of
Glass
Non Reflective
(NR)
Mislite
(FM)
Figure Flora
(FF)
Kasumi
(FKS)

Standard
Thickness
(mm)
2
3
5
3
4

Coating
Position

#1
#2
#1
#2
#1
#2
#1
#2
#1
#2

Energy Characteristic
Transmittance Reflectance
(%)
84
84
81
81
74
74
79
79
80
80

(%)
7
7
8
6
7
6
7
6
7
6

Absorption
(%)
9
9
11
13
19
20
14
15
13
14

Light Characteristic
Ultra Violet
Transmission Transmittance Reflectance
(%)
(%)
(%)
68
89
8
68
89
8
64
90
10
64
90
6
58
85
7
58
85
7
68
90
8
68
90
7
62
88
7
62
88
7

Solar
Factor
%

Light Characteristic
Ultra Violet
transmission Transmittance Reflectance
(%)
(%)
(%)
35
63
35
35
63
34
33
62
35
33
62
34
18
44
34
18
44
19
15
41
34
15
41
17
11
35
34
11
35
14
12
49
27
12
49
16
8
39
34
8
39
16
12
54
35
12
54
26
10
52
34
10
52
25
7
48
34
6
45
20
9
29
34
9
29
11
6
23
34
7
24
9
36
14
31
36
14
6
6
32
34
6
32
21
5
30
34
5
31
20
3
27
34
3
27
16
9
26
34
9
26
15
8
24
34
9
25
15
6
21
34
6
21
12

Solar
Factor
%

86
86
84
84
80
80
83
83
84
84

Shading
U
Coeficient Value
*3*4
W/m2k
0.99
0.99
1.00
0.97
0.92
0.92
0.95
0.96
0.97
0.97

5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9
5.9

STOPSOL
Type
Of
Glass
Stopsol
Supersilver
Clear
(SSFL)
Stopsol
Supersilver
Dark Blue
(SSDH)
Stopsol
Supersilver
Blue Green
(SSBN)
Stopsol
Supersilver
Green
(SSGN)
Stopsol
Supersilver
Euro Grey
(SSGE)
Stopsol Supersilver
Dark Grey (SSDG)

Standard
Thickness
(mm)
6
8
5
6
8
6
8
5
6
8
6
8
5
5

Stopsol
Classic Green
(CGN)

6
8
5

Stopsol
Classic Dark Blue
(CDH)

6
8

Coating
Position

#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2

Energy Characteristic
Transmittance Reflectance
(%)
64
64
62
62
34
34
30
30
24
24
33
33
24
24
37
37
33
33
27
24
34
34
26
27
34
34
25
25
20
22
16
16
22
22
20
20
15
15

(%)
27
24
27
23
26
13
26
12
26
10
21
10
26
10
26
15
26
14
26
11
27
10
26
8
23
8
28
12
28
11
28
9
28
10
28
10
28
8

Absorption
(%)
9
12
11
15
40
53
44
58
50
66
46
57
50
66
37
48
41
53
47
65
39
56
48
65
44
58
47
63
52
67
56
75
50
68
52
70
57
77

66
67
64
66
44
48
41
45
37
41
45
48
37
41
46
49
43
47
39
41
44
48
39
43
46
51
37
41
33
39
30
35
35
40
34
38
30
35

Shading
U
Coeficient Value
*3*4
W/m2k
0.76
0.77
0.74
0.76
0.51
0.55
0.47
0.52
0.43
0.47
0.52
0.55
0.43
0.47
0.53
0.56
0.49
0.54
0.45
0.47
0.51
0.55
0.45
0.49
0.54
0.59
0.43
0.47
0.38
0.45
0.34
0.40
0.40
0.46
0.39
0.44
0.34
0.40

5.7
5.7
5.7
5.7
5.8
5.8
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.8
5.8
5.7
5.7
5.7
5.7
5.7
5.7
5.7
5.6
5.8
5.8
5.8
5.8
5.7
5.7
5.7
5.7
5.8
5.8
5.7
5.7
5.7
5.7

SUNERGY
Type
Of
Glass

Standard
Thickness
(mm)

Coating
Position

Sunergy Green
SNGN
Sunergy Blue Green
SNBN
Sunergy Euro Grey
SNGE

3
4
5
6
8
10
6
8
6
8
6
8

#2
#2
#2
#2
#2
#2
#2
#2
#2
#2
#2
#2

Type
Of
Glass

Standard
Thickness
(mm)

Coating
Position

Planibel G

3.2
4
5
6

#2
#2
#2
#2

Sunergy Clear
SNFL

Energy Characteristic
Transmittance Reflectance
(%)
56
58
55
54
52
50
31
26
29
23
30
24

(%)
10
10
10
9
9
9
6
6
6
5
6
6

Absorption
(%)
34
34
35
37
39
41
63
68
65
72
64
70

Light Characteristic
Ultra Violet
transmission Transmittance Reflectance
(%)
(%)
(%)
43
69
9
41
69
9
40
68
9
38
68
9
36
67
9
33
66
8
12
56
7
9
52
7
13
48
7
10
42
6
13
34
5
9
26
4

Solar
Factor
%
63
62
61
61
59
58
42
39
41
37
42
37

Shading
U
Coeficient Value
*3*4
W/m2k
0.72
0.71
0.70
0.70
0.68
0.67
0.48
0.45
0.47
0.43
0.48
0.43

4.2
4.2
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1

PLANIBEL G
Energy Characteristic
Transmittance Reflectance
(%)
71
70
69
68

(%)
11
11
11
10

Absorption
(%)
18
19
20
22

Light Characteristic
Ultra Violet
transmission Transmittance Reflectance
(%)
(%)
(%)
47
82
11
45
82
11
43
81
11
41
81
11

Solar
Factor
%
74
73
72
71

Shading
U
Coeficient Value
*3*4
W/m2k
0.85
0.84
0.83
0.82

3.7
3.7
3.7
3.7

Remarks :
The data are calculated using spectral measurements that are conform to standards EN 410 (1998), ISO 9050, WIS/WINDAT, Illuminant A
observer 20 CIE 1931.
Energy properties according to ISO / DIS 9050, NFRC 100-2001 and/or EN 410.
U value (formerly k-value) is calculated according to standard ISO EN 673 and/or NFRC 100-2001 conditions.
Ultra Violet Transmittance according ISO/DIS 9050 table 4, DIN 67507 clause 6 table 4, pr-EN 410 table 3 (280nm-380nm).
This document is no evaluation of the risk of glass breakage due to thermal stress. For tempered glass the risk of spontaneous breakage due
to Nickel-Sulfide is not covered by PT Asahimas Flat Glass Tbk. The Heat Soak Test is available on request.
Specifications, technical and other data are based on information available at the time of preparation of this document and are subject to
change without notice. PT Asahimas Flat Glass Tbk ca not be held responsible for any deviation between the data introduced and the the
conditions on site.

CIKAMPEK FACTORY : BUKIT INDAH INDUSTRIAL PARK , SEKTOR IA, BLOK J-L, CIKAMPEK, JAWA BARAT , INDONESIA
PHONE : (62-264) - 351711 (HUNTING) ; FAX : (62-264)-351710
SIDOARJO FACTORY : TANJUNG SARI, TAMAN, SIDOARJO, 61257 JAWA TIMUR, INDONESIA, PO BOX : 1481 / SBY-SURABAYA
PHONE : (62-31) -7882383 (HUNTING) ; 7882135 ; FAX : 7882842 ;7882149