Customer : MHK

Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-40 - EXTERNAL POWER

** ON A/C ALL

24-40 - EXTERNAL POWER


24-40-00 - EXTERNAL POWER
24-40-00 PB 001 CONF 00 - EXTERNAL POWER - DESCRIPTION AND OPERATION
1. General
Two external power receptacles (EXT PWR A and EXT PWR B) located aft the nose landing gear well enable
the connection.
The aircraft can then be supplied by two Ground Power Units (GPU).
The ground power unit enables the supply of:
either the whole network via the EXT PWR A receptacle and/or the EXT PWR B receptacle (see transfer
circuit 24-41-00)
or the ground service network via the EXT PWR A receptacle. This network comprises:
. the AC ground service bus control (Ref. AMM D/O 24-42-00-00) ,
. the DC ground service bus control (Ref. AMM D/O 24-43-00-00) . .
2. Component Location
(Ref. Fig. Main Components - Component Location SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 1 of 3

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-40 - EXTERNAL POWER

5001VU
800VU(852VU)

A
A
710VU
718VU
FR18
FR14

717VU
725VU

735VU
722VU

715VU
FR18

721VU

235VU

19XG
20XG
925VU

F_MM_244000_0_AAN0_01_00

Figure 24-40-00-12200-00-B / SHEET 1/1 - Main Components - Component Location


** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 2 of 3

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-40 - EXTERNAL POWER

FIN

FUNCTIONAL DESIGNATION

PANEL

ZO
NE

ACCESS
DOOR

4XG
EPC-A
715VU 120
7XG
IND LT-EXT PWR A/NOT IN USE
925VU 120
8XG
CAUT LT-EXT PWR A/AVAIL
925VU 120
10XG
P/BSW-ELEC/EXT A
235VU 210
20XG
RCPT-EXT PWR
121EL
120
21XG
CT-EXT PWR A
715VU 120
1XX
RCCB-111XP GROUND SUPPLY
725VU 120
2XX
RCCB-212XP GROUND SUPPLY
715VU 120
3XX
RCCB-113XP GROUND SUPPLY
725VU 120
4XX
RCCB-214XP GROUND SUPPLY
715VU 120
6XX
CNTOR-TR2 GROUND SUPPLY
715VU 120
16XX
SW-GND SELECT CTL
5001VE 223
3XG
EPC-B
715VU 120
19XG
RCPT-EXT PWR
121EL
120
22XG
CT-EXT PWR B
715VU 120
17XG
P/BSW-ELEC EXT B
235VU 210
40XG
GAPCU
852VU 122
Figure 24-40-00-12200-00-B / SHEET 1/1 - Main Components - Component Location

ATA REF

24-41-55
24-41-00
24-41-00
24-41-00
24-41-51
24-41-17
24-42-56
24-42-56
24-42-56
24-42-56
24-42-55
24-42-00
24-41-55
24-41-51
24-41-17
24-41-00
24-41-34