Sei sulla pagina 1di 27

Think Foxboro

SCADA Roadmap
May 2013
Rev 2013.5.1
Slide 2

Think
SCADA

Legal Disclaimer
INVENSYS has prepared this document for sole use with Opsmanage13 only.
Date

Company

Contact

Email

Tel

5-8 May

Opsmanage13 ANZ

Chris J Smith

Chris.j.smith@invensys.com

--

Copyright INVENSYS 2013.


The information contained herein is the property of INVENSYS and any other use or
disclosure of such information is prohibited.
This report shall not be reproduced, copied or used in whole or in part without prior
written approval of INVENSYS.
All rights reserved.
The names, logos, and taglines identifying the products and services of Invensys are
proprietary marks of Invensys or its subsidiaries.
All third party trademarks and service marks are the proprietary marks of their respective
owners.
Not for distribution.
All dates are currently scheduled dates and are subject to change.

Invensys Proprietary & Confidential

Holistic SCADA Layered Terminology


APPS

MTU

Comms

RTU

Instrumentation

ASSET, PIPELINE, POWER, Load Control

SUPERVISORY CONTROL - OPERATIONS INTEGRATION /


COMMUNICATIONS BACKUP Control Centres

Wireless, Networks [Vendor, User, 3rd Party Providers]

Remote Controller, Data Aquisition, Remote Gateway

Metering, Protection, IO Subsystems, Safety Systems

CONFIDENTIAL

Recent Releases
Recent Major Updates
- SCD5200 Firmware
and Tools

Slide 7

Invensys Proprietary & Confidential

FEATURES - New F/W Release 2013


This release significantly enhances the overall IEC61850
capability of the SCD5200 as well as expanding the overall
port capacity and instances of protocol stack. This is in line
with the modern practice of redundant data concentration for
many 3rd Party IEDs within the architecture.
FIRMWARE VERSION SY-1101190_P
Release Date : April 2013

Slide 8

Invensys Proprietary & Confidential

IEC61850 Architectures Simplified


Co-Resident IEC61850 Client and IEC61850 Server operation
within a single SCD5200 Node
Optonet is NOT required to allow data transfers between client and server
Architectures can be simplified

KEMA IEC61850 Certification of both IEC61850 Client and Server


Operation
Avoids the need for further end-user qualification and testing of IEC61850 operation

Updated IEC61850 Schema


IEC61850 is a maturing standard and this brings the older firmware up to date in
support of the IEC61850 SCL language and Schema

Other Enhancements

The maximum number of increased to 150 within a single node


A 50 per cent increase in port capacity

More than double the number of DNP protocol stacks allowed

Slide 9

Invensys Proprietary & Confidential

IEC 61850 RELATED SERVER UPDATE


Server Time activated Operate for Controls

Server CILO and RSYN LNs


Control Interlock and Synchro Check

Server On, Off and Blocked Modes

Server Status Check before Execute


Server String Types now visible over Optonet
Server ENUM and CODED types now available to other
protocols and applications in SALL User Language

Slide 10

Invensys Proprietary & Confidential

SCADA Roadmap
May 2013
Rev 2013.5.1

Intelligent
SCADA

Automate Intelligence
Photo : Leshanes123 Flickr

Slide11
2012 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys or its

subsidiaries. All third party trademarks and service marks are the proprietary marks of their respective owners. All dates herein subject to change.

Roadmap Business Drivers

End of Life Components New OS Versions


Migration / New Functionality
- Memory
RoHS and REACH
Installed Base
- CPUs
Products and
EU Directives
- Oscillators
Capability
coming into
force in 2017
IEC61850
Web based
Technologies

Invensys Proprietary & Confidential

SCD5200/SCD6000 Roadmap 2013

I/O subsystem.

Device & Sys


Int.

Controller

Software

Applications

2012

2013

2014

2015

2016

2017

2018

2019

2020

2021

Database, IDF, User Level SALL and IEC 61131 Programming

Configuration and Diagnostic


Tools

Configuration and Diagnostic


Tools

Main Processor 64MB

Main Processor 512MB

Data Concentration and Communications


Open Standard Protocols, User defined Communications, SALL, IDF,

Rationalize IO configurations and Range


Optimize Total Cost of Ownership
Invensys Proprietary & Confidential

SCD5200/6000 Roadmap 2013

I/O subsystem.

Device & Sys


Int.

Controller

Software

Applications

2012

2013

2014

2015

2016

2017

2018

2019

2020

2021

Secure Authorization

Configuration and Diagnostic Tools


Simplify configuration, maintenance and change management

Main Processor
Manage Larger Distributed Databases and Faster Response Times

Data Concentration and Communications


Open Standard Protocols, User defined Communications, SALL, IDF,

Rationalize IO configurations and Range


Optimize Total Cost of Ownership
Invensys Proprietary & Confidential

SCD5200/6000 Roadmap = Values


2016

2017

2018

2019

2020

Preserve Engineering, Programs, and Artifacts


SALL, .IDF, .CFG

Maintain latest OS, Security, and Patches


Utilize greater applications flexibility
Improve Performance
Extend Performance
Assist higher level use of Object Oriented Structures
Include Secure Serial and Network Connectivity
Better Port Diagnostics and Capture
Higher Density of Intelligent IEDs

I/O subsystem.

Applications

2015

Software

2014

Controller

2013

Device & Sys


Int.

2012

2021

Modernize to increase IO density and rationalize for Spare Parts


RoHs [Reduction of Hazardous Substances] Directives
Invensys Proprietary & Confidential

SCD5200/6000 Roadmap 2012-2016


2013

2014

ArchestrA SCADA 2014

SY-1101190_P

2015

IEC 61850 Runtime


Integration

IEC 61850 TEST and


SIMULATION ANALYSIS

Contrlrs

Secure Collaboration
[MTU/RTU]

SCD6000 IEC 61850 TEST and


SIMULATION MODULE

SCD2200 Mercury

IEC 61850 SCD5200


Client/Server Update

SCD6000 Engineering Security Diagnostics


SCD6000 CPU

SCD5200 Upgrade
with SCD6000
Controller

SCD6000 ELECTROBUS Comms

Device &
System Int.
I/O
subsystem.

2016

IASCADA Migration

Network /
Security

Applications &
Software

2012

SCD6000 ELECTROBUS IO

SCD6000 Electrobus IO and Comms. Modules


SCD5200 RITTAL
CARD FILE

SCD5200
Upgrade with
SCD6000
Series RoHS
I/O

SCD5200 DEEP ADI


Terminations

LEGEND: BLUE under development; YELLOW planned


Invensys Proprietary & Confidential

Work in Progress .. Stage III and above

Slide 17

ADI Module - Deeper


Terminal Block

New Cardfile - Rittal

Proposal 167 SCD6000

Invensys Proprietary & Confidential

Work in Progress .. Deeper ADI Block

Funding allocated
Prototype
Constructed
Feedback ?
Moulding [12wk]
RTP October Likely

Slide 18

Invensys Proprietary & Confidential

Proposal
Proposal167
167

Maintains Bus Compatibility


Electrobus
SCD6000
Optonet
Translator
Data
SCD6000 Concentrator
Gateway Data
RTU50
[1993 2013] Concentrator

SCD6000
ELECTROBUS RTU

SCD5200
[2002 2016]

SCD5200
RTU50
Slide 19

Increasing Functional Replacement of SCD5200

Deliverables
The objective deliverables of this proposal are all variants of
SCD6000 CPU which would enable any variant of the
SCD5200 and RTU50 COPE, COE, P30E to be functionally
upgraded.
These variants would appear to the market as:
SCD6000 Gateway Data Concentrator
SCD6000 Translator Data Concentrator
SCD6000 ELECTROBUS RTU

Slide 20

Do not delete any slides or content. Mark as Not Applicable.

The SCD6000 Processor Upgrade


Developments
SCD6000 Processor
Replaces

SY-0399143 SCD5200 COPE [16MB]

SY-0399144 SCD5200 COE [16MB]

SY-0399145 RTU50 P3E [16MB]

SY-0399152 SCD5200 COPE [64MB

SY-0399153 SCD5200 COE [64MB]

SY-0399154 RTU50 P3OE [64MB]

Slide 21

Invensys Proprietary & Confidential

Lifecycle and Migration [Session 2]

Slide 22

Invensys Proprietary & Confidential

Lifecycle Phase
MATURE

AVAILABLE PREFERRED
IASCADA
1997++

P6009

SCADA-A2

ArchestrA
SCADA
2014

InFusion SCADA
2.1
{2010++}

Substation
Automation
Configurator

LN2068
1988++

NEW PRODUCTS

Releases

LIFETIME

Upgrade / Migration Planning

C2020
C2025
1970++

RTU20
1999++

SCD2200
SCD2100
2010++

C50/RTU50
1993++

MTU
RTU

New

P6008
1980++

Substation
Automation
System

SCD5200
{2003 2016}

Global Customer Support Customer First Service

SCD2200
SCD2100
SCD6200

Foxboro RTU

Product Migration Plan

Manufacturer : Shanghai Foxboro Company Limited

Life Cycle
Phase

RTU50

SCD5200

Preferred

Technology Advance
1993-2005
2002-2015

Available

2006-2013

2016-2017

Mature

2014-2016

2017++

Lifetime

2017++

SCD6000
2016++

RTU50 SCD5200 Migration Strategy


Function

Feature

RTU50

SCD5200

SCD6000

Euro/China RoHs Directive

Lead Free Modules

NO

NO

YES

CPU

Electrobus/Optonet

P30E [64MB]

COPE/COE[64MB]

COPE/COE

Electrobus

1 to 4 files

1 File

1 File

Optobus

1 8 files

Not Supported

Not Supported

Optonet

1 50 files

1 50 files

1 50 Nodes

SALL / IDF

Yes

Yes

Yes

Wisp+

Yes

Yes

No

Conitel

Yes

Yes

Yes

LN57

Yes

No

No

DNP

Yes

Yes

Yes

DNP Secure
IEC62351-5

No

No

Yes

IEC 60870-5101/103/104

Yes

Yes

Yes

Intelligent Bus

IEC 61850 Client

Yes

Yes

Yes

Intelligent Bus

IEC 61850 Server

Yes

Yes

Yes

BUS Hardware

Engineering
Protocols

RTU50 SCD5200 Migration Strategy


Main Use

Feature

RTU50

SCD5200

SCD6000

T/D

Wide Range [24-164]

YES

YES

Ultra Wide PS

T/D

P30E

COPE/COE

COPE/COE

T/D

Use Optonet

Optonet

Optonet

Electrobus Extn.

Use Optonet

Optonet

Optonet

8-12 Ch Serial Module

12 Channel

8 Channel

8 Channel

Dual V11

YES

YES

TBA

Dual V28

YES

YES

YES

Legacy 1200 Baud

Dual V23

YES

NO

NO

Distribution

Dual Glass Optical

YES

YES

YES

Transmission

32DI/4AI

YES

YES

YES [32 DI ONLY]

Transmission

20AI

YES

YES

YES

Transmission AGC

4 AO [Setpoint]

YES

YES

YES

Distribution 11/33kV

IO [24DI/6AI/8DO]

NO

YES

YES

General

DO

12 CH [1A]

12CH[1A]

12CH[1A]

{Distribution}

CTVT MODULE[PQ]

3CT/4VT / 2DO

3CT/4VT / 2DO

3CT/4VT / 2DO

Slide 27

Invensys Proprietary & Confidential

Responsibility to each other

And we want your help.......


Slide 28

Invensys Proprietary & Confidential

For an overview audience, the roadmap


presentation could end here. However there will be
opportunities to present to internal & external
customers where greater detail is required for a
specific product, for a grouping of products (some of
which may be on roadmaps outside of this portfolio),
or for other reasons. The following slides illustrate
ways of tying the overview map into details slides.

Potrebbero piacerti anche