Sei sulla pagina 1di 7

Trishuli Galchhi Hydro Electric Project - 75 MW

Project: Trishuli Galchhi Hydro Electric Project - 75 MW


Specifications:
1

Location
1

Country

Nepal

District

Dhading/Nuwakot

Zone

Bagmati

Stream

Trishuli

River

Trishuli

Latitude

- Weir

2751'14"

- Power House

2748'26"

Longitude
- Weir

8502'13"

- Power House

8458'20"

Nearest Village

Dhodbesi

Nearest Town

Trishuli Bidur (15km)

10

Nearest City

Kathmandu (63 km)

11

Nearest Air- Port

Kathmandu (63 km)

Purpose of the Project

Generation and Transmission


Hydro Electric Power

Installed Capacity

2 x 37.5 MW

Annual Average Energy Generation

468.15WHr.

Hydrology
1

Catchment Area

Average Annual Rainfall

Average Annual Yield

Design Power Discharge

of

5731 sqkm
Nuwakot 1913.3mm
Dhading 2124mm
8400 Mcum
84.70 cumecs/ Unit, at rated head

Minimum Power Discharge

25.41 cumecs/ Unit, at 30% design


discharge

Maximum design Flood (at main Weir


site)

5100 cumecs

Diversion Weir
1

Location

Weir across Trishuli, near Dhodbesi,


in Dhading/Nuwakot District, 15km

1|Page
www.designgroup.in

Trishuli Galchhi Hydro Electric Project - 75 MW


from Trishuli Bidur.
2

Type

Barrage Type Structure with gates


and sheet piles water sealing
through the dam

FRL

EL.445.00 m

MWL

EL.445.00 m

MDDL / MOL

EL.441.00m

Top of Overflow Section

EL.447.00 m

Weir Crest

EL.425.00 m

Deepest Foundation Level

EL.420.50 m

Height of the weir (from deepest


foundation level)

24.5 m

10

Length of Overflow Section

136.00 m

11

Length of Non overflow Section

222.52m

12

Total Length

391.52m

13

Flood discharge capacity of Weir

5100 cumecs

14

Energy Dissipating Arrangement

Stilling Basin

15

Spillway Gates
i)Service Gates
a)Nos.

b)Type

Radial gate

c)Size

12.0 m x 5.50m

d)Sill Level

EL.425.00 m

e)Hoist platform Level

EL.442.00m

f)Hoist Type

Rope drum Hoist

ii)Stop Log Gate

a)Nos.

b)Type

Vertical Lift Gate

c)Size

12.0 m x 6.00m

d)Sill Level

EL 425.00 m

e)Hoist platform Level

EL 447.00 m

f)Hoist Type

Gantry Crane

De-Silting Chamber Intake


i) Nos.

ii) Sill Level

EL.437.00 m

2|Page
www.designgroup.in

Trishuli Galchhi Hydro Electric Project - 75 MW

iii) Hoist Bridge Level

EL.447.00 m

iv) Design Discharge

101.64cumecs/each compartment

v) Gates
(a) Service Gate
Nos.

Size

12.00 m x 8.00 m

Type

Vertical lift roller gate

Hoist

Gantry Crane

(b) Stop log Gate


Nos.

Size

12.00 m x 8.00 m

Type

Vertical lift roller gate

Hoist Type

Gantry Crane

De-Silting Chamber
RCC

Type

Shape

Rectangular

Nos

Size

Length 180m, Width 20m

Flow

Free Flow

Depth of flow

12.7 m

Silt Flushing Arrangement


(i) Gate
Nos.

10

Size

9.00 m x 3.00 m

Type

Vertical lift roller gate

Hoist

Gantry Crane

HRT Intake
i) Nos.

ii) Sill Level

EL.417.834 m

iii) Hoist Bridge Level

EL.446.00 m

iv) Design Discharge

169.4 cumecs

v) Gates

3|Page
www.designgroup.in

Trishuli Galchhi Hydro Electric Project - 75 MW

(a) Service Gate


Size

7.90 m x 7.90 m

Type

Vertical lift roller gate

Hoist

Rope drum hoist

(b) Stop log Gate


Nos.

11

Size

10.00 m x 11.00 m

Type

Vertical lift roller gate

Hoist

Rope drum hoist

Head Race Tunnel (HRT)


1

Type

RCC Lined Tunnel

Shape

Horse shoe

Size

7.90 m dia

Thickness

350mm

Flow

Pressure Flow

Length

8000.00 m

Invert level at start

EL.420.467 m

Invert level at end

EL.396.10 m

Bed Gradient

1 in 328.86

12

Surge Shaft
1

Type

Orifice

Diameter

30.0 m Dia

Max. Surge Level

EL.454.50 m

Min Surge Level

EL.408.00 m

Invert level

EL.396.10 m

Height

60.9m

Wall Thickness

500mm

Type of Wall

RCC M-20, A-20

13

Penstock Tunnel
1

Type

CC lined, 350mm thick.

Shape

Horse Shoe

Size

6.250 m dia

Flow

Pressure Flow

Length

200.00 m

4|Page
www.designgroup.in

Trishuli Galchhi Hydro Electric Project - 75 MW

6
14

1 in 328.07

Penstocks
1

Type

Steel Penstock, buried

No. of Penstock

Internal Dia.

6.25 m

Inclined Length

79.26 m

Shell Thickness

32, 40 mm

Branch line

15

16

Bed slope

Dia

4.5 m

Thickness

28 mm

Length (Total)

30.00 m

Power House
1

Location

Just near the Prithvi Highway


connecting Kathmandu-Pokhara and
near Handikholagaun village

Type

Surface type

Size of Machine Hall(outer to outer)

41.00 m x 22.00 m

Size of Service Bay

20.00 m x 22.00 m

Size of Control room

37.68 m x 5.5 m

No. of Bays

2 unit bays and one Service bay

No. of Units and Capacity

2 Units of 37500 kW each

El. Of Turbine C/L

EL.382.50 m

Generator Floor Level

EL.395.00 m

10

Control Room Floor Level

EL.397.00m

11

Service/Equipment handling Bay

EL 397.00 m

12

Draft tube floor Level

EL 374.00 m

13

HFL

EL 395.00 m

14

Max. TWL (two units)

EL 386.29 m

15

Min TWL

EL 384.50 m

Draft Tube Gates


a)Nos.

b)Type

Vertical Lift Gate

c)Size

6.150 m X 4.250 m

d)Sill Level

EL.374.03 m

5|Page
www.designgroup.in

Trishuli Galchhi Hydro Electric Project - 75 MW

17

EL.397.00 m

f)Hoist

Gantry Crane

Tail Race Pool


1

Length

23.910 m

Max. TWL (two units)

EL 386.29 m

Bed Width

38.3 m

Side Slopes

Design Discharge

169.4 cumecs

Bed Slope

1 in 3

Bed Levels

Varying from EL 375.53 m to EL


383.50 m

18

i ) Rock- 1(V):0.25(H)
ii ) Soil -1(V):1(H)

Turbines
1

Type

Vertical Francis

Rated Output

38660 kW

Maximum Net Head

58.88 m

Minimum Net Head

46.33 m

Rated Head

50.03 m

Rated Discharge per unit

84.70 cumecs

Maximum Discharge per unit

84.70 cumecs

Rated Speed

150 rpm

Runner Dia

3600 mm

Efficiency at rated output

93 %

10
19

Generators
1

Type

Synchronous

Rated Output

37500 kW

Generation Voltage

11 kV

Rated Speed

150 rpm

Efficiency

97 %

20

21

e)Hoist Level

Transmission Lines
1

Length

3. km

Terminal Point

132 kV substation at Galchhi

Type

132 kV Double Circuit Line

Out Door Yard

6|Page
www.designgroup.in

Trishuli Galchhi Hydro Electric Project - 75 MW

Size

74.00m x 39.5m

No. of Power Transformers

Capacity of Power Transformer

50 MVA

Step up Voltage of Transformer

132 kV

22

Cost
1

4
23

Estimated cost of Civil Works in


NRs(000)

5142700

Estimated cost of E & M Works in


NRs(000)

2079900

Estimated cost of T -Transmission in


NRs(000)

95200

Total Project Cost in NRs(000)

9923165

Energy (PPA)
1

Total Energy Generation

468.15 GWHr

Salable Energy

454.10 GWHr

Implementation Schedule

42 Months from Zero date

24

Thanks for your interest in our services.


Please do reach us at
Design Group Project Consultants (P) Ltd.
110/4, M. Krishnappa Layout, Lalbagh Road,
Bangalore 560 027.
India.
Phone: + 91 80 22238706, 22242658, 22242570
Fax: 22227308
Email: designgroup@vsnl.com

7|Page
www.designgroup.in

Potrebbero piacerti anche