Sei sulla pagina 1di 82

SingleRAN

Common Clock Feature Parameter


Description
Issue

01

Date

2014-04-30

HUAWEI TECHNOLOGIES CO., LTD.

Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address:

Huawei Industrial Base


Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website:

http://www.huawei.com

Email:

support@huawei.com

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

Contents

Contents
1 About This Document..................................................................................................................1
1.1 Scope..............................................................................................................................................................................1
1.2 Intended Audience..........................................................................................................................................................2
1.3 Change History...............................................................................................................................................................2
1.4 Differences Between Base Station Types.......................................................................................................................2

2 Overview.........................................................................................................................................3
3 Common GPS Reference Clock..................................................................................................5
3.1 Common GPS Reference Clock in Separate-MPT Multimode Base Stations...............................................................6
3.2 Common GPS Reference Clock in Co-MPT Multimode Base Stations........................................................................7
3.3 Common GPS Reference Clock in Hybrid-MPT Multimode Base Stations..................................................................7

4 Common BITS Reference Clock...............................................................................................11


4.1 Common BITS Reference Clock in Separate-MPT Multimode Base Stations............................................................12
4.2 Common BITS Reference Clock in Co-MPT Multimode Base Stations.....................................................................13
4.3 Common BITS Reference Clock in Hybrid-MPT Multimode Base Stations..............................................................13

5 Common E1/T1 Reference Clock..............................................................................................16


5.1 Common E1/T1 Reference Clock in Separate-MPT Multimode Base Stations...........................................................17
5.2 Common E1/T1 Reference Clock in Co-MPT Multimode Base Stations....................................................................18
5.3 Common E1/T1 Reference Clock in Hybrid-MPT Multimode Base Stations.............................................................19

6 Common IEEE 1588v2 Reference Clock..................................................................................23


6.1 Common IEEE 1588v2 Reference Clock in Separate-MPT Multimode Base Stations...............................................25
6.2 Common IEEE 1588v2 Reference Clock in Co-MPT Multimode Base Stations........................................................27
6.3 Common IEEE 1588v2 Reference Clock in Hybrid-MPT Multimode Base Stations.................................................27

7 Common Synchronous Ethernet Reference Clock................................................................31


7.1 Common Synchronous Ethernet Reference Clock in Separate-MPT Multimode Base Stations.................................33
7.2 Common Synchronous Ethernet Reference Clock in Co-MPT Multimode Base Stations..........................................35
7.3 Common Synchronous Ethernet Reference Clock in Hybrid-MPT Multimode Base Stations....................................35

8 Other Common Reference Clocks............................................................................................39


8.1 Common 1PPS+TOD Reference Clock in Co-MPT GSM/UMTS/LTE Triple-mode Base Stations..........................40
8.2 Common IEEE 1588v2+SyncE Reference Clock in Co-MPT GSM/UMTS/LTE Triple-mode Base Stations...........40
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

ii

SingleRAN
Common Clock Feature Parameter Description

Contents

9 Engineering Guidelines.............................................................................................................42
9.1 When to Use Common Clock.......................................................................................................................................42
9.2 Required Information...................................................................................................................................................42
9.3 Requirements................................................................................................................................................................42
9.4 Initial Configuration.....................................................................................................................................................44
9.4.1 GBTS/eGBTS Providing Clock Source for NodeB/eNodeB/Co-MPT Base Station................................................44
9.4.2 NodeB Providing Clock Source for GBTS/eGBTS/eNodeB/Co-MPT Base Station................................................51
9.4.3 The eNodeB Providing Clock Source for GBTS/eGBTS/NodeB/Co-MPT Base Station.........................................55
9.4.4 Co-MPT Base Station Providing Clock Source for GBTS/eGBTS/NodeB/eNodeB................................................60
9.4.5 Co-MPT Base Station Supporting Common Reference Clock among GSM, UMTS, and LTE...............................65
9.5 Activation Observation.................................................................................................................................................68
9.6 Troubleshooting............................................................................................................................................................69

10 Parameters...................................................................................................................................70
11 Counters......................................................................................................................................76
12 Glossary.......................................................................................................................................77
13 Reference Documents...............................................................................................................78

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

iii

SingleRAN
Common Clock Feature Parameter Description

1 About This Document

About This Document

1.1 Scope
This document describes the Common Clock feature, which applies to the scenario in which
baseband unit (BBU) sharing is implemented on a multimode base station. Common clocks in
multimode base stations can be classified into:
l

GSM/UMTS common clock

GSM/LTE common clock

UMTS/LTE common clock

GSM/UMTS/LTE common clock

With BBU sharing, boards of different modes are installed in one BBU. BBU sharing can be
implemented on one BBU or two interconnected BBUs.
For details about clock configuration of a single-mode base station, see Synchronization Feature
Parameter Description for this mode. The Common Clock feature involves the following
features:
l

MRFD-211601 Multi-mode BS Common Reference Clock(GBTS/eGBTS)

MRFD-221601 Multi-mode BS Common Reference Clock(NodeB)

MRFD-231601 Multi-mode BS Common Reference Clock (eNodeB)

MRFD-241601 Multi-mode BS Common Reference Clock(LTE TDD)


NOTE

l BTS, NodeB, and eNodeB correspond to the GSM, UMTS, and LTE modes of a multimode base station,
respectively.
l Before reading this document, familiarize yourself with Synchronization Feature Parameter
Description for each mode, including eRAN, RAN, and GBSS.
l MRFD-231601 Multi-mode BS Common Reference Clock (eNodeB) is an LTE FDD feature and
MRFD-241601 Multi-mode BS Common Reference Clock(LTE TDD) is an LTE TDD feature. Unless
otherwise specified, the LTE mode and eNodeB mentioned in this document do not differentiate
between FDD and TDD.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

1 About This Document

1.2 Intended Audience


This document is intended for personnel who:
l

Need to understand the features described herein

Work with Huawei products

1.3 Change History


This section provides information about the changes in different document versions. There are
two types of changes, which are defined as follows:
l

Feature change
Changes in features of a specific product version

Editorial change
Changes in wording or addition of information that was not described in the earlier version

SRAN9.0 01 (2014-04-30)
This issue does not include any changes.

SRAN9.0 Draft A (2014-01-20)


Compared with Issue 01 (2013-04-28) of SRAN8.0, Draft A (2014-01-20) of SRAN9.0 includes
the following changes.
Change Type

Change Description

Parameter
Change

Feature change

Added common clocks for the LTE TDD mode.

None

Added the description of BBU interconnection,


For details, see 2 Overview.
Huawei mobile network management system
M2000 is renamed U2000.
Editorial change

Split "Common GPS/BITS Reference Clock" into


two sections: " Common GPS Reference Clock "
and " Common BITS Reference Clock".

None

1.4 Differences Between Base Station Types


The features described in this document apply only to macro base stations.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

2 Overview

Overview

With the Common Clock feature, all modes of a multimode base station share a clock source
and require only one set of clock equipment.
The Common Clock feature applies to GSM/UMTS, GSM/LTE, or UMTS/LTE dual-mode and
GSM/UMTS/LTE triple-mode base stations where the BBU Interconnection feature is applied.
The Common Clock feature helps reduce operating expense (OPEX) and capital expenditure
(CAPEX).
A multimode base station can be configured with the following common reference clocks:
l

GPS reference clock

Building integrated timing supply (BITS) reference clock

E1/T1 reference clock

IEEE 1588v2 reference clock

Synchronous Ethernet reference clock

1PPS+TOD reference clock

These reference clocks are described in the following chapters.


Application scenarios of the Common Clock feature include:
l

Separate-MPT scenario: Separate-MPT main controls boards are used in GSM, UMTS,
and LTE modes.
If all modes in a multimode base station are configured in the same BBU, all modes
exchange data by using the BBU backplane and share a clock source. If the modes of a
multimode base station are configured in two different BBUs, the BBU Interconnection
feature must be enabled.
The following restrictions apply to this scenario:
A multimode base station does not support the AUTO(Auto Handover) clock working
mode. Each mode in a multimode base station can be configured with only one clock
source.
A multimode base station can be configured with only one USCU board and the USCU
board can be configured with only one clock source.
If the LTE TDD or LTE FDD mode are used in a multimode base station, the shared
clock source must support and use time synchronization.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

2 Overview

In the inter-subrack SDR scenario, it is not allowed to configure frequency


synchronization for the mode in the primary BBU and time synchronization for the
mode in the secondary BBU at the same time.
l

Co-MPT scenario: The GBTS/eGBTS, NodeB, and eNodeB share a UMPT board.
The UMPT board provides the clock source for each mode and supports the Common Clock
feature. The clock source provided by the UMPT board supports frequency synchronization
and time synchronization. If the LTE TDD mode is used, the clock source of the UMPT
board must support and use time synchronization.
NOTE

l The UMPT board can be configured for a single-mode base station. UMPT_G, UMPT_U, and
UMPT_L represent the UMPT board configured for GSM, UMTS, and LTE single-mode base stations,
respectively.
l The UMPT board can be configured for a dual-mode or triple-mode base station. UMPT_GU,
UMPT_GL, UMPT_UL, and UMPT_GUL represent the UMPT board configured for GSM/UMTS,
GSM/LTE, UMTS/LTE, and GSM/UMTS/LTE multimode base stations, respectively.
l In an LTE FDD and LTE TDD dual-mode base station, LTE FDD and LTE TDD support only coMPT.

Hybrid-MPT scenario: Separate-MPT and co-MPT scenarios coexist.


In this scenario, single-mode base stations are configured with separate-MPT main control
boards, and multimode base stations are configured with co-MPT main control boards.
The main control board shared by different modes supports the Common Clock feature.
The clock source provided by the main control board supports frequency
synchronization and time synchronization. If the LTE TDD mode is used, the clock
source of the co-MPT main control board must support and use time synchronization.
The modes that use separate-MPT main control boards and the modes that use co-MPT
main control boards share a clock source. The restrictions in this scenario are the same
as those in the separate-MPT scenario.
NOTE

To achieve BBU interconnection, you can connect one UCIU board and one UMPT board or connect
two UMPT boards. The two methods use the same configurations. In this document, BBU
interconnection is achieved by connecting one UCIU board and one UMPT board.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

3 Common GPS Reference Clock

Common GPS Reference Clock

This chapter describes the common GPS reference clock in separate-MPT, co-MPT, and hybridMPT multimode base stations.
NOTE

In this chapter, the UMPT board is in LTE TDD mode and configured with a GPS satellite card, such as
UMPT_L, UMPT_UL, UMPT_GL, and UMPT_GUL.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

3 Common GPS Reference Clock

3.1 Common GPS Reference Clock in Separate-MPT


Multimode Base Stations
The USCU board in a dual-mode base station receives GPS clock signals and forwards them to
the two main control boards in the base station through the backplane. Alternatively, the LMPT/
UMPT_L board receives GPS clock signals and forwards them to another mode through the
backplane. Figure 3-1, Figure 3-2, and Figure 3-3 show a common GPS reference clock in a
separate-MPT dual-mode base station.
Figure 3-1 A common GPS reference clock in a separate-MPT GSM/UMTS dual-mode base
station

Figure 3-2 A common GPS reference clock in a separate-MPT GSM/LTE dual-mode base
station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

3 Common GPS Reference Clock

Figure 3-3 A common GPS reference clock in a separate-MPT UMTS/LTE dual-mode base
station

3.2 Common GPS Reference Clock in Co-MPT Multimode


Base Stations
As shown in Figure 3-4, GSM/UMTS, GSM/LTE, UMTS/LTE, or GSM/UMTS/LTE
multimode base stations are configured in co-MPT mode and share a GPS clock source.
Figure 3-4 A common GPS reference clock in a co-MPT multimode base station

3.3 Common GPS Reference Clock in Hybrid-MPT


Multimode Base Stations
As shown in Figure 3-5, only one BBU is used. The USCU board receives GPS clock signals
and forwards them to the main control boards in the multimode base station through the
backplane. Alternatively, the LMPT, UMPT_L, UMPT_GL, or UMPT_UL board receives GPS
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

3 Common GPS Reference Clock

clock signals and forwards them to another main control board through the backplane. This
allows different modes of a base station to share a GPS reference clock.
Figure 3-5 A common GPS reference clock in a hybrid-MPT triple-mode base station

When BBU Interconnection is enabled, the GPS reference clock is shared as follows:
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

3 Common GPS Reference Clock

As shown in Figure 3-6, the GPS interface is located in the primary BBU of a GSM/UMTS/
LTE triple-mode base station. The USCU board receives GPS clock signals and forwards
them to the GTMU and UMPT_L boards through the backplane. Alternatively, the LMPT
or UMPT_L board receives GPS clock signals and forwards them to the GTMU board
through the backplane. Upon receiving the clock signals, the GTMU board forwards them
to the UCIU board. This UCIU board then sends the clock signals to the UMPT_U board
in the secondary BBU, which receives them through its BBU interconnection port.

As shown in Figure 3-7, the GPS interface is located in the secondary BBU of a GSM/
UMTS/LTE triple-mode base station. The USCU board receives GPS clock signals and
forwards them to the UMPT_L board through the backplane, which in turn sends them
through its BBU interconnection port to the UCIU board in the primary BBU. Alternatively,
the LMPT/UMPT_L board receives GPS clock signals and sends them through its BBU
interconnection port to the UCIU board in the primary BBU. This UCIU board then sends
the clock signals to the GTMU and WMPT/UMPT_U boards through the backplane.
Figure 3-6 A common GPS reference clock in the primary BBU of a GSM/UMTS/LTE
triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

SingleRAN
Common Clock Feature Parameter Description

3 Common GPS Reference Clock

Figure 3-7 A common GPS reference clock in the secondary BBU of a GSM/UMTS/LTE triplemode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

10

SingleRAN
Common Clock Feature Parameter Description

4 Common BITS Reference Clock

Common BITS Reference Clock

This chapter describes the common BITS reference clock in separate-MPT, co-MPT, and hybridMPT multimode base stations. The BITS reference clock only supports frequency
synchronization, and does not support time synchronization. The LTE mode and eNodeB
mentioned in this chapter refer to FDD.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

11

SingleRAN
Common Clock Feature Parameter Description

4 Common BITS Reference Clock

4.1 Common BITS Reference Clock in Separate-MPT


Multimode Base Stations
As shown in Figure 4-1, Figure 4-2, and Figure 4-3, the USCU board in a dual-mode base
station receives BITS clock signals and forwards them to the two main control boards in the
base station.
Figure 4-1 A common BITS reference clock in a separate-MPT GSM/UMTS dual-mode base
station

Figure 4-2 A common BITS reference clock in a separate-MPT GSM/LTE dual-mode base
station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

12

SingleRAN
Common Clock Feature Parameter Description

4 Common BITS Reference Clock

Figure 4-3 A common BITS reference clock in a separate-MPT UMTS/LTE dual-mode base
station

4.2 Common BITS Reference Clock in Co-MPT Multimode


Base Stations
As shown in Figure 4-4, GSM/UMTS, GSM/LTE, UMTS/LTE, or GSM/UMTS/LTE
multimode base stations are configured in co-MPT mode and share a BITS reference clock.
Figure 4-4 A common BITS reference clock in a co-MPT multimode base station

4.3 Common BITS Reference Clock in Hybrid-MPT


Multimode Base Stations
As shown in Figure 4-5, only one BBU is used. The USCU board receives BITS clock signals
and forwards them to the main control boards in the multimode base station. This allows different
modes of a base station to share a BITS reference clock.
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

13

SingleRAN
Common Clock Feature Parameter Description

4 Common BITS Reference Clock

Figure 4-5 A common BITS reference clock in a hybrid-MPT triple-mode base station

When BBU Interconnection is enabled, the BITS reference clock is shared as follows:
l

As shown in Figure 4-6, the USCU board is installed in the primary BBU of a GSM/UMTS/
LTE triple-mode base station. The USCU board receives BITS clock signals and forwards
them to the GTMU and LMPT/UMPT_L boards. Upon receiving the clock signals, the
GTMU board forwards them to the UCIU board. The UCIU board then sends the clock
signals to the UMPT_U board in the secondary BBU, which receives them through its BBU
interconnection port.

As shown in Figure 4-7, the USCU board is installed in the secondary BBU of a GSM/
UMTS/LTE triple-mode base station. The USCU board receives BITS clock signals and
forwards them to the UMPT_U board, which in turn sends them through its BBU
interconnection port to the UCIU board in the primary BBU. The UCIU board then sends
the clock signals to the GTMU and LMPT/UMPT_L boards through the backplane.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

14

SingleRAN
Common Clock Feature Parameter Description

4 Common BITS Reference Clock

Figure 4-6 A common BITS reference clock in the primary BBU of a GSM/UMTS/LTE
triple-mode base station

Figure 4-7 A common BITS reference clock in the secondary BBU of a GSM/UMTS/LTE
triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

15

SingleRAN
Common Clock Feature Parameter Description

5 Common E1/T1 Reference Clock

Common E1/T1 Reference Clock

This chapter describes the common E1/T1 reference clock in separate-MPT, co-MPT, and
hybrid-MPT multimode base stations. The E1/T1 reference clock only supports frequency
synchronization, and does not support time synchronization. The LTE mode and eNodeB
mentioned in this chapter refer to FDD.
Table 5-1 describes the typical application scenarios for a common E1/T1 reference clock.
Table 5-1 Typical application scenarios for a common E1/T1 reference clock
Deploymen
t Scenario

Description

Common E1/
T1 reference
clock over
the Abis
interface

When the Abis interface uses E1/T1 transmission and the Iub or S1 interface
uses IP over FE/GE transmission, the NodeB or eNodeB can obtain E1/T1
clock signals from an E1/T1 link over the Abis interface.

Common E1/
T1 reference
clock over
the Iub
interface

When the Abis interface on the multimode base station side uses IP cotransmission or IP hybrid transmission, the eGBTS or GBTS can obtain E1/
T1 clock signals from an E1/T1 link over the Iub interface.
When the Iub interface uses E1/T1 transmission and the S1 interface uses IP
over GE transmission, the eNodeB can obtain E1/T1 clock signals from an
E1/T1 link over the Iub interface.

NOTE

Only the UMTS mode can obtain E1/T1 clock signals from a UTRP board.
The LTE mode can obtain E1/T1 clock signals only from a UMPT board.
For details about the Common Transmission feature, see Common Transmission Feature Parameter
Description for SingleRAN.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

16

SingleRAN
Common Clock Feature Parameter Description

5 Common E1/T1 Reference Clock

5.1 Common E1/T1 Reference Clock in Separate-MPT


Multimode Base Stations
As shown in Figure 5-1, Figure 5-2, and Figure 5-3, one mode of a multimode base station is
configured with an E1/T1 clock source, and then the other modes share E1/T1 clock signals by
using the BBU backplane.
Figure 5-1 A common E1/T1 reference clock in a separate-MPT GSM/UMTS dual-mode base
station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

17

SingleRAN
Common Clock Feature Parameter Description

5 Common E1/T1 Reference Clock

Figure 5-2 A common E1/T1 reference clock in a separate-MPT GSM/LTE dual-mode base
station

Figure 5-3 A common E1/T1 reference clock in a separate-MPT UMTS/LTE dual-mode base
station

5.2 Common E1/T1 Reference Clock in Co-MPT Multimode


Base Stations
As shown in Figure 5-4, each mode uses the E1/T1 clock source configured for the UMPT
board. The UMPT board supports the Common Clock feature.
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

18

SingleRAN
Common Clock Feature Parameter Description

5 Common E1/T1 Reference Clock

Figure 5-4 A common E1/T1 reference clock in a co-MPT GSM/UMTS/LTE triple-mode base
station

5.3 Common E1/T1 Reference Clock in Hybrid-MPT


Multimode Base Stations
As shown in Figure 5-5, only one BBU is used. Different modes of base stations can share an
E1/T1 clock source by using the BBU backplane.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

19

SingleRAN
Common Clock Feature Parameter Description

5 Common E1/T1 Reference Clock

Figure 5-5 A common E1/T1 reference clock in a hybrid-MPT GSM/UMTS/LTE triple-mode


base station

When BBU Interconnection is enabled, one mode of a GSM/UMTS/LTE triple-mode base


station is configured with an E1/T1 clock source and the other two modes share the E1/T1 clock
source. The procedure for sharing the E1/T1 clock source is as follows:
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

20

SingleRAN
Common Clock Feature Parameter Description

5 Common E1/T1 Reference Clock

As shown in Figure 5-6 , the common E1/T1 reference clock is in the primary BBU of a
GSM/UMTS/LTE triple-mode base station. The GTMU board receives E1/T1 clock signals
from the transport network over an E1/T1 link and forwards them to the LMPT and UCIU
boards. Upon receiving the clock signals, the UCIU board sends them to the UMPT board
in the secondary BBU, which receives them over the BBU interconnection port.

As shown in Figure 5-7, the common E1/T1 reference clock is in the secondary BBU of a
GSM/UMTS/LTE triple-mode base station. The UMPT board receives E1/T1 clock signals
from the transport network over an E1/T1 link and forwards them to the UCIU board in the
primary BBU. Upon receiving the clock signals, the UCIU board sends them to the GTMU
and LMPT boards by using the BBU backplane.
Figure 5-6 A common E1/T1 reference clock in the primary BBU of a GSM/UMTS/LTE
triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

21

SingleRAN
Common Clock Feature Parameter Description

5 Common E1/T1 Reference Clock

Figure 5-7 A common E1/T1 reference clock in the secondary BBU of a GSM/UMTS/LTE
triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

22

SingleRAN
Common Clock Feature Parameter Description

6 Common IEEE 1588v2 Reference Clock

Common IEEE 1588v2 Reference Clock

This chapter describes the common IEEE 1588v2 reference clock in separate-MPT, co-MPT,
and hybrid-MPT multimode base stations.
Table 6-1 describes the typical application scenarios for a common IEEE 1588v2 reference
clock.
Table 6-1 Typical application scenarios for a common IEEE 1588v2 reference clock
Deployment Scenario

Description

Common IEEE 1588v2 reference clock over


the Iub interface

When the Abis and Iub interfaces use IP


transmission and the NodeB of a multimode
base station is configured with an IEEE
1588v2 clock source, the BTS can obtain
clock signals from the WMPT or UMPT
board in the NodeB by using the BBU
backplane.
When the Iub and S1 interfaces use IP
transmission and the NodeB of a multimode
base station is configured with an IEEE
1588v2 clock source, the eNodeB can obtain
clock signals from the WMPT or UMPT
board in the NodeB by using the BBU
backplane.

Common IEEE 1588v2 reference clock over


the S1 interface

Issue 01 (2014-04-30)

When the Abis or Iub interface and the S1


interface use the IP transmission and the
eNodeB of a multimode base station is
configured with an IEEE 1588v2 clock
source, the GBTS, eGBTS, or NodeB can
obtain clock signals from the LMPT or
UMPT board in the eNodeB by using the
BBU backplane.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

23

SingleRAN
Common Clock Feature Parameter Description

Issue 01 (2014-04-30)

6 Common IEEE 1588v2 Reference Clock

Deployment Scenario

Description

Common IEEE 1588v2 reference clock over


the Abis interface

When the eGBTS or GBTS of a multimode


base station is configured with an IEEE
1588v2 clock source, the NodeB or eNodeB
can obtain clock signals from the GTMUb
board in the GBTS or the UMPT_G board in
the eGBTS by using the BBU backplane.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

24

SingleRAN
Common Clock Feature Parameter Description

6 Common IEEE 1588v2 Reference Clock

6.1 Common IEEE 1588v2 Reference Clock in Separate-MPT


Multimode Base Stations
As shown in Figure 6-1, Figure 6-2, Figure 6-3, one main control board serving a mode is
connected to the transport network using an FE/GE port. The board is configured with an IEEE
1588v2 clock client to obtain clock signals from an IEEE 1588v2 clock server. The oscillator
in the board synchronizes clock signals with the IEEE 1588v2 clock server and transmits the
synchronized 1 pulse per second (PPS) clock signals to the other main control board serving
another mode. In this case, only one IEEE 1588v2 clock client is required. FE stands for fast
Ethernet and GE stands for gigabit Ethernet.
Only LTE TDD shares the IEEE 1588v2 reference clock to other modes, not vice versa. If other
modes share the IEEE 1588v2 reference clock to LTE TDD, the reference clock can use
frequency synchronization only. This is because LTE TDD supports only time synchronization.
Figure 6-1 A common IEEE 1588v2 reference clock in a separate-MPT GSM/UMTS dual-mode
base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

25

SingleRAN
Common Clock Feature Parameter Description

6 Common IEEE 1588v2 Reference Clock

Figure 6-2 A common IEEE 1588v2 reference clock in a separate-MPT GSM/LTE dual-mode
base station

Figure 6-3 A common IEEE 1588v2 reference clock in a separate-MPT UMTS/LTE dual-mode
base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

26

SingleRAN
Common Clock Feature Parameter Description

6 Common IEEE 1588v2 Reference Clock

6.2 Common IEEE 1588v2 Reference Clock in Co-MPT


Multimode Base Stations
As shown in Figure 6-4, each mode uses the IEEE 1588v2 clock source configured for the
UMPT board. The UMPT board supports the Common Clock feature. The shared IEEE 1588v2
reference clock supports frequency synchronization and time synchronization. If the LTE TDD
mode is used, the clock source must use time synchronization.
Figure 6-4 A common IEEE 1588v2 reference clock in a co-MPT GSM/UMTS/LTE triplemode base station

6.3 Common IEEE 1588v2 Reference Clock in Hybrid-MPT


Multimode Base Stations
As shown in Figure 6-5, only one BBU is used. Different modes of base stations can share an
IEEE 1588v2 clock source by using the BBU backplane. Only LTE TDD shares the IEEE 1588v2
reference clock to other modes, not vice versa. If other modes share the IEEE 1588v2 reference
clock to LTE TDD, the reference clock can use frequency synchronization only. This is because
LTE TDD supports only time synchronization.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

27

SingleRAN
Common Clock Feature Parameter Description

6 Common IEEE 1588v2 Reference Clock

Figure 6-5 A common IEEE 1588v2 reference clock in a hybrid-MPT GSM/UMTS/LTE triplemode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

28

SingleRAN
Common Clock Feature Parameter Description

6 Common IEEE 1588v2 Reference Clock

When BBU Interconnection is enabled, one mode of a GSM/UMTS/LTE triple-mode base


station is configured with an IEEE 1588v2 clock source and the other two modes share the IEEE
1588v2 clock source. The procedure for sharing the IEEE 1588v2 clock source is as follows:
l

As shown in Figure 6-6, the common IEEE 1588v2 reference clock is in the primary BBU
of a GSM/UMTS/LTE triple-mode base station. The LMPT board is configured with an
IEEE 1588v2 clock client and receives IEEE 1588v2 clock packets containing clock signals
from an IEEE 1588v2 clock server through the transport network. Then, the LMPT board
generates synchronized 1 PPS clock signals and forwards them to the GTMU and UCIU
boards. Upon receiving the synchronized 1 PPS clock signals, the UCIU board sends them
to the UMPT board in the secondary BBU. Base stations of other modes in the primary
BBU obtain 1 PPS clock signals by using the BBU backplane.

As shown in Figure 6-7, the common IEEE 1588v2 reference clock is in the secondary
BBU of a GSM/UMTS/LTE triple-mode base station. The UMPT board is configured with
an IEEE 1588v2 clock client and receives IEEE 1588v2 clock packets containing clock
signals from an IEEE 1588v2 clock server through the transport network. Then, the UMPT
board generates synchronized 1 PPS clock signals and forwards them to the UCIU board
in the primary BBU, which in turn forwards them to the GTMU and WMPT boards.

Transmission port cabling on a multimode base station and the cabling of a common IEEE
1588v2 reference clock are independently deployed. Therefore, the operation of the multimode
base station is not affected.
Figure 6-6 A common IEEE 1588v2 reference clock in the primary BBU of a GSM/UMTS/
LTE triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

29

SingleRAN
Common Clock Feature Parameter Description

6 Common IEEE 1588v2 Reference Clock

Figure 6-7 A common IEEE 1588v2 reference clock in the secondary BBU of a GSM/UMTS/
LTE triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

30

SingleRAN
Common Clock Feature Parameter Description

7 Common Synchronous Ethernet Reference Clock

Common Synchronous Ethernet Reference


Clock
This chapter describes the common synchronous Ethernet reference clock in separate-MPT, coMPT, and hybrid-MPT multimode base stations. The synchronous Ethernet reference clock only
supports frequency synchronization, and does not support time synchronization. The LTE mode
and eNodeB mentioned in this chapter refer to FDD.
Table 7-1 describes the typical application scenarios for a common synchronous Ethernet
reference clock.
Table 7-1 Typical application scenarios for a common synchronous Ethernet reference clock

Issue 01 (2014-04-30)

Deployme
nt Scenario

Description

Common
synchronous
Ethernet
reference
clock over
the Iub
interface

When the Iub interface on the multimode base station side uses IP transmission
and the IP network supports Ethernet clock synchronization, the eGBTS,
GBTS, or eNodeB can obtain clock signals from the WMPT, UMPT, UTRP
board in the NodeB by using the BBU backplane. The UTRP board is managed
by the UMTS mode and supports FE/GE transmission.

Common
synchronous
Ethernet
reference
clock over
the S1
interface

When the S1 interface uses IP transmission and the IP network supports


Ethernet clock synchronization, the eGBTS, GBTS, or NodeB can obtain
clock signals from the LMPT, UMPT, UTRP board in the eNodeB by using
the BBU backplane. The UTRP board is managed by the LTE mode and
supports FE/GE transmission.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

31

SingleRAN
Common Clock Feature Parameter Description

Issue 01 (2014-04-30)

7 Common Synchronous Ethernet Reference Clock

Deployme
nt Scenario

Description

Common
synchronous
Ethernet
reference
clock over
the Abis
interface

When the eGBTS or GBTS of a multimode base station is configured with a


synchronous Ethernet clock source, the NodeB or eNodeB can obtain clock
signals by using the BBU backplane from any of the following boards:
l UMPT or UTRP board in the eGBTS
l GTMUb or UTRP board in the GBTS
The UTRP board is managed by the GSM mode and supports FE/GE
transmission.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

32

SingleRAN
Common Clock Feature Parameter Description

7 Common Synchronous Ethernet Reference Clock

7.1 Common Synchronous Ethernet Reference Clock in


Separate-MPT Multimode Base Stations
As shown in Figure 7-1, Figure 7-2, Figure 7-3, to implement a common synchronous Ethernet
reference clock, one mode of a dual-mode base station must connect to the transport network
over its FE/GE port and the IP network must support Ethernet clock synchronization. This
ensures that the other mode of the base station can receive synchronous Ethernet clock signals
by using the BBU backplane.
Figure 7-1 A common synchronous Ethernet reference clock in a separate-MPT GSM/UMTS
dual-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

33

SingleRAN
Common Clock Feature Parameter Description

7 Common Synchronous Ethernet Reference Clock

Figure 7-2 A common synchronous Ethernet reference clock in a separate-MPT GSM/LTE dualmode base station

Figure 7-3 A common synchronous Ethernet reference clock in a separate-MPT UMTS/LTE


dual-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

34

SingleRAN
Common Clock Feature Parameter Description

7 Common Synchronous Ethernet Reference Clock

7.2 Common Synchronous Ethernet Reference Clock in CoMPT Multimode Base Stations
As shown in Figure 7-4, each mode uses the synchronous Ethernet clock source configured for
the UMPT board. The UMPT board supports the Common Clock feature.
Figure 7-4 A common synchronous Ethernet reference clock in a co-MPT GSM/UMTS/LTE
triple-mode base station

7.3 Common Synchronous Ethernet Reference Clock in


Hybrid-MPT Multimode Base Stations
As shown in Figure 7-5, only one BBU is used. Different modes of base stations can share a
synchronous Ethernet clock source by using the BBU backplane.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

35

SingleRAN
Common Clock Feature Parameter Description

7 Common Synchronous Ethernet Reference Clock

Figure 7-5 A common synchronous Ethernet reference clock in a hybrid-MPT GSM/UMTS/


LTE triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

36

SingleRAN
Common Clock Feature Parameter Description

7 Common Synchronous Ethernet Reference Clock

When BBU Interconnection is enabled, one mode of a GSM/UMTS/LTE triple-mode base


station is configured with a synchronous Ethernet clock source and the other two modes share
the clock source. The procedure for sharing the synchronous Ethernet clock source is as follows:
l

As shown in Figure 7-6, the common synchronous Ethernet reference clock in the primary
BBU of a GSM/UMTS/LTE triple-mode base station. The WMPT board receives
synchronous Ethernet clock signals from the transport network over an FE link and
forwards them to the GTMU and UCIU boards. Upon receiving the clock signals, the UCIU
board sends them to the UMPT board in the secondary BBU. The other mode of base station
in the primary BBU obtains synchronous Ethernet clock signals by using the BBU
backplane.

As shown in Figure 7-7, the common synchronous Ethernet reference clock in the
secondary BBU of a GSM/UMTS/LTE triple-mode base station. The UMPT board receives
synchronous Ethernet clock signals from the transport network over a GE link and forwards
them to the UCIU board in the primary BBU. Upon receiving the clock signals, the UCIU
board sends them to the GTMU and WMPT boards.
Figure 7-6 A common synchronous Ethernet reference clock in the primary BBU of a
GSM/UMTS/LTE triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

37

SingleRAN
Common Clock Feature Parameter Description

7 Common Synchronous Ethernet Reference Clock

Figure 7-7 A common synchronous Ethernet reference clock in the secondary BBU of a GSM/
UMTS/LTE triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

38

SingleRAN
Common Clock Feature Parameter Description

8 Other Common Reference Clocks

Other Common Reference Clocks

When the GSM, UMTS, and LTE modes share a UMTS board, besides common GPS, BITS,
E1/T1, IEEE 1588v2, and synchronous Ethernet reference clocks, the following common
reference clocks can be used:
l

Common 1PPS+TOD reference clock

Common IEEE 1588v2+SyncE reference clock

These two common reference clocks are used only when the GSM, UMTS, and LTE modes
share a UMPT board. This is because these two common reference clocks only support a single
mode in a separate-MPT multimode base station.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

39

SingleRAN
Common Clock Feature Parameter Description

8 Other Common Reference Clocks

8.1 Common 1PPS+TOD Reference Clock in Co-MPT GSM/


UMTS/LTE Triple-mode Base Stations
The 1PPS+TOD clock source supports frequency synchronization and time synchronization. As
shown in Figure 8-1, the USCU and UMPT boards can receive 1PPS+TOD clock signals. The
UMPT board is configured with the 1PPS+TOD clock source, which is shared by the GSM,
UMTS, and LTE modes.
Figure 8-1 A common 1PPS+TOD reference clock in a co-MPT GSM/UMTS/LTE triple-mode base station

8.2 Common IEEE 1588v2+SyncE Reference Clock in CoMPT GSM/UMTS/LTE Triple-mode Base Stations
The IEEE 1588v2+SyncE clock source combines the IEEE 1588v2 clock and synchronous
Ethernet clock and supports only time synchronization. The clock source of the IEEE 1588v2
clock server must be the same as that of the synchronous Ethernet. As shown in Figure 8-2, the
UMPT board is configured with the IEEE 1588v2+SyncE clock source, which is shared by the
GSM, UMTS, and LTE modes. The clock source of the IEEE 1588v2 clock server and the
synchronous Ethernet in Figure 8-2 are GPS.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

40

SingleRAN
Common Clock Feature Parameter Description

8 Other Common Reference Clocks

Figure 8-2 A common IEEE 1588v2+SyncE reference clock in a co-MPT GSM/UMTS/LTE triple-mode base station

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

41

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Engineering Guidelines

9.1 When to Use Common Clock


It is recommended that MRFD-211601 Multi-mode BS Common Reference Clock(GBTS/
eGBTS), MRFD-221601 Multi-mode BS Common Reference Clock(NodeB), or
MRFD-231601 Multi-mode BS Common Reference Clock (eNodeB) be enabled for a
multimode base station to reduce the OPEX and CAPEX.

9.2 Required Information


The information to be collected is as follows:
l

Whether the multimode base station using the LTE TDD mode is configured with a GPS
antenna
If the multimode base station is configured with a GPS antenna, it is recommended that all
modes of the base station share a GPS reference clock.

Transmission scheme used by the multimode base station that does not use the LTE TDD
mode
If at least one mode of the multimode base station uses E1/T1 transmission, use a
common E1/T1 reference clock.
If all modes of the multimode base station use FE/GE transmission, check whether
synchronous Ethernet is supported. If yes, use a common synchronous Ethernet
reference clock. If no, use a common IEEE 1588v2 reference clock.

9.3 Requirements
MRFD-211601 Multi-mode BS Common Reference Clock(GBTS/eGBTS), MRFD-221601
Multi-mode BS Common Reference Clock(NodeB), MRFD-231601 Multi-mode BS Common
Reference Clock(eNodeB), and MRFD-241601 Multi-mode BS Common Reference Clock(LTE
TDD) are under license control.
MRFD-231601 Multi-mode BS Common Reference Clock(eNodeB) and MRFD-241601 Multimode BS Common Reference Clock(LTE TDD) have license control items. The other two
features only have license sales items and do not have license control items.
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

42

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Feature
ID

Feature
Name

License Control Item

NE

Sales Unit

MRFD-23
1601

Multimode BS
Common
Reference
Clock
(eNodeB)

Function-LTELLT1MCRC01 Common
Clock (eNodeB) (per
eNodeB)

eNodeB

per eNodeB

MRFD-24
1601

Multimode BS
Common
Reference
Clock(LTE
TDD)

eNodeB

Per eNodeB

The following are the requirements for FDD(TDD):


l

The TDD eNodeB can only use the GPS reference clock provided by the GBTS/eGBTS
that uses time synchronization.

The TDD eNodeB can only use the GPS reference clock provided by the NodeB that uses
time synchronization.

The TDD eNodeB can only use the GPS reference clock provided by the co-MPT base
station that uses time synchronization.

If the LTE TDD mode is used in a multimode base station, a clock source that supports
time synchronization must be used, for example, GPS reference clock, IEEE 1588v2
reference clock, 1PPS+TOD reference clock, or IEEE 1588v2+SyncE reference clock. In
addition, the clock source must use time synchronization.

This feature applies only to GSM/UMTS/LTE triple-mode base stations.

If a BITS reference clock is used, a USCU board must be installed in the BBU.

Hardware

Other Features
l

Common GPS reference clock


GBFD-510401 BTS GPS Synchronization
MRFD-210501 BTS/NodeB Clock
LBFD-00300504 Synchronization with BITS
TDLBFD-00300503 Synchronization with GPS

Common BITS reference clock


MRFD-210501 BTS/NodeB Clock
LBFD-00300504 Synchronization with BITS

l
Issue 01 (2014-04-30)

Common synchronous Ethernet reference clock


Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.

43

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

GBFD-118202 Synchronous Ethernet


WRFD-050502 Synchronous Ethernet
LOFD-00301301 Synchronization with Ethernet(ITU-T G.8261)
l

Common IEEE 1588v2 reference clock


MRFD-210501 BTS/NodeB Clock
WRFD-050501 Clock Sync on Ethernet in NodeB
LOFD-00301302 IEEE 1588v2 Clock Synchronization
TDLOFD-00301302 IEEE1588 V2 Clock Synchronization

Common 1PPS+TOD reference clock


MRFD-210501 BTS/NodeB Clock
LBFD-00300505 Synchronization with 1PPS
TDLBFD-00300505 Synchronization with 1PPS

Common IEEE 1588v2+SyncE reference clock


GBFD-118202 Synchronous Ethernet
WRFD-050502 Synchronous Ethernet
LOFD-00301302 IEEE 1588v2 Clock Synchronization
LOFD-00301301 Synchronization with Ethernet(ITU-T G.8261)

9.4 Initial Configuration


This document provides system clock configuration for each of the NEs that share a clock source
and their common reference clock configuration. For details about how to configure the clock
source of the NE that provides the common reference clock, see Synchronization Feature
Parameter Description for the corresponding mode. This section describes how to configure a
common clock in typical application scenarios.

9.4.1 GBTS/eGBTS Providing Clock Source for NodeB/eNodeB/CoMPT Base Station


The configuration procedure involves configuring the reference clock on the GBTS or eGBTS
side and Configuring a Common Reference Clock for NodeB/eNodeB/Co-MPT Base
Station. To configure a reference clock on the GBTS or eGBTS side, refer to one of the following
sections:
l

Configuring a Common GPS Reference Clock on the GBTS or eGBTS Side

Configuring a Common BITS Reference Clock on the GBTS or eGBTS Side

Configuring a Common E1/T1 Reference Clock on the GBTS or eGBTS Side

Configuring a Common IEEE 1588v2 Reference Clock on the GBTS or eGBTS Side

Configuring a Common Synchronous Ethernet Reference Clock on the GBTS or


eGBTS Side

Configuring a Common GPS Reference Clock on the GBTS or eGBTS Side


Before configuring a common GPS reference clock, ensure that the GBTS or eGBTS has been
configured with a USCU board.
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

44

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

To configure a common GPS reference clock for the GBTS, perform the following steps:
Step 1 Run the SET BTSUSCUBP command to add a GPS clock link.
Step 2 Run the SET BTSCLK command with ClkType (the CME name is Clock Type) set to
TRCGPS_CLK(Trace GPS Clock).
----End
To configure a common GPS reference clock for the eGBTS, perform the following steps:
Step 1 Run the ADD GPS command to add a GPS clock link.
Step 2 Run the SET CLKMODE command to activate the GPS reference clock. Set the key parameters
according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


GPS(GPS Clock).

----End

Configuring a Common BITS Reference Clock on the GBTS or eGBTS Side


Before configuring a common BITS reference clock, ensure that the GBTS or eGBTS has been
configured with a USCU board.
To configure a common BITS reference clock for the GBTS, perform the following step:
Run the SET BTSCLK command with ClkType (the CME name is Clock Type) set to
EXTSYN_CLK(External Sync clock).
To configure a common BITS reference clock for the eGBTS, perform the following steps:
Step 1 Run the ADD BITS command to add a BITS clock link.
Step 2 Run the SET CLKMODE command to activate the BITS reference clock. Set the key
parameters according to the descriptions in the following table.

Issue 01 (2014-04-30)

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


BITS(BITS Clock).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

45

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

----End

Configuring a Common E1/T1 Reference Clock on the GBTS or eGBTS Side


Before configuring a common E1/T1 reference clock, ensure that an E1/T1 clock link is
available.
To configure a common E1/T1 reference clock for the GBTS, perform the following step:
Run the SET BTSCLK command with ClkType (the CME name is Clock Type) set to
TRCBSC_CLK(Trace BSC Clock).
To configure a common E1/T1 reference clock for the eGBTS, perform the following steps:
Step 1 Run the ADD LINECLK command to add an E1/T1 clock link. In this step, set Port Type
(Port Type on the CME) to E1T1(E1T1).
Step 2 Run the SET CLKMODE command to activate the E1/T1 reference clock. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


LINECLK(Line
Clock).

----End

Configuring a Common IEEE 1588v2 Reference Clock on the GBTS or eGBTS Side
To configure a common IEEE 1588v2 reference clock for the GBTS, perform the following
steps:
Step 1 Run the SET BTSIPCLKPARA command to configure parameters for an IEEE 1588v2 clock
link. Set the key parameters according to the descriptions in the following table.

Issue 01 (2014-04-30)

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Clock Protocol Type

CLKPRTTYPE

Clock Protocol Type

Set this parameter to


PTP(PTP).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

46

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

IP Clock Time
Synchronization
Mode

SYNMode

Clock
Synchronization
Mode

Set this parameter to


CONSYN
(Consecutive
Synchronizing) or
INTERSYN
(Intermittent
Synchronizing).

Clock Topology
Mode

CLKTOPOMODE

Clock Topology
Mode

Set this parameter to


PTPOVERUDP
(PTP over UDP
Unicast) or
PTPOVERMAC
(PTP over MAC
Multicast).

Clock Reference
Source Redundancy

ISCLKREDUCY

Clock Reference
Source Redundancy

Set this parameter to


UNSUPPORT(Not
Support Reducy) or
SUPPORT
(Support Reducy).

Clock Server 0 IP
Address

MASTERIPADDR

Clock Server 0 IP
Address

Set this parameter to


the IP address of
clock server 0 on the
IP clock link.

Clock Server 1 IP
Address

SLAVEIPADDR

Clock Server 1 IP
Address

Set this parameter to


the IP address of
clock server 1 on the
IP clock link.

Step 2 Run the SET BTSCLK command with ClkType (the CME name is Clock Type) set to
IP_TIME(IP Clock).
----End
To configure a common IEEE 1588v2 reference clock for the eGBTS, perform the following
steps:
Step 1 Run the ADD IPCLKLINK command to add an IEEE 1588v2 clock link. Set the key parameters
according to the descriptions in the following table.

Issue 01 (2014-04-30)

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Protocol Type

ICPT

Protocol Type

Set this parameter to


PTP(PTP).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

47

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Profile Type

PROFILETYPE

Profile Type

Set this parameter to


1588V2(1588V2),
G.8265.1(G.8265.1)
or 1588V2_16.1.
In most cases, set this
parameter to 1588V2
(1588V2). If the IP
clock server is a
third-party device, it
is recommended that
this parameter be set
to G.8265.1(G.
8265.1) to ensure the
correct interworking
between the base
station and the IP
clock server.

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates
the IP clock link.

Clock Topology
Mode

CNM

Clock Net Mode

Set this parameter to


UNICAST
(Unicast),
L3_MULTICAST
(L3 Multicast), or
L2_MULTICAST
(L2 Multicast).

Client IP

CIP

Client IPv4

Set this parameter to


the IPv4 address of
the client at the IP
clock link.

Server IP

SIP

Server IPv4

Set this parameter to


the IPv4 address of
the server at the IP
clock link.

NOTE

If the IEEE 1588v2 clock server and the eGBTS are on different network segments, run the ADD IPRT
command to configure the route between the IEEE 1588v2 clock server and the eGBTS.

Step 2 Run the SET CLKMODE command to activate the IEEE 1588v2 reference clock. Set the key
parameters according to the descriptions in the following table.
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

48

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


IPCLK(IP Clock).

IP Clock Time
Synchronization
Mode

SYNMODE

Synchronization
Mode

Set this parameter to


ABSOLUTE
(ABSOLUTE),
RELATIVE
(RELATIVE), or
OFF(OFF).

----End

Configuring a Common Synchronous Ethernet Reference Clock on the GBTS or


eGBTS Side
Before configuring a common synchronous Ethernet reference clock, ensure that all transmission
equipment supports the synchronous Ethernet.
To configure a common synchronous Ethernet reference clock for the GBTS, perform the
following step:
Run the SET BTSCLK command with ClkType (the CME name is Clock Type) set to
SYNETH_CLK(SynEth Clock). Then, run the ADD SYNCETH command to add a
synchronous Ethernet clock link. Set the key parameters according to the descriptions in the
following table.

Issue 01 (2014-04-30)

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates
the synchronous
Ethernet clock link.

Port No.

PN

Port No.

Set this parameter to


the number of the
port that
accommodates the
synchronous
Ethernet clock link.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

49

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

To configure a common synchronous Ethernet reference clock for the eGBTS, perform the
following steps:
Step 1 Run the ADD SYNCETH command to add a synchronous Ethernet clock link. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates
the synchronous
Ethernet clock link.

Port No.

PN

Port No.

Set this parameter to


the number of the
port that
accommodates the
synchronous
Ethernet clock link.

SSM Selection

SSM

Synchronization
Status Message

Set this parameter to


DISABLE
(DISABLE) or
ENABLE
(ENABLE).

Step 2 Run the SET CLKMODE command to activate the synchronous Ethernet reference clock. Set
the key parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


SYNCETH
(SyncEth Clock).

----End

Configuring a Common Reference Clock for NodeB/eNodeB/Co-MPT Base Station


Step 1 Run the ADD PEERCLK command to add a peer reference clock link.
Step 2 Run the SET CLKMODE command to configure the working mode of the reference clock.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

50

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


PEERCLK(Peer
Clock).

----End

9.4.2 NodeB Providing Clock Source for GBTS/eGBTS/eNodeB/CoMPT Base Station


The configuration procedure involves configuring the reference clock on the NodeB side and
Configuring a Common Reference Clock on the GBTS Side or Configuring a Common
Reference Clock on the eGBTS/eNodeB/Co-MPT Base Station side. To configure a reference
clock on the NodeB side, refer to one of the following sections:
l

Configuring a Common GPS Reference Clock on the NodeB Side

Configuring a Common BITS Reference Clock on the NodeB Side

Configuring a Common E1/T1 Reference Clock on the NodeB Side

Configuring a Common IEEE 1588v2 Reference Clock on the NodeB Side

Configuring a Common Synchronous Ethernet Reference Clock on the NodeB Side

Configuring a Common GPS Reference Clock on the NodeB Side


Before configuring a common GPS reference clock, ensure that the NodeB has been configured
with a USCU board.
Step 1 Run the ADD GPS command to add a GPS clock link.
Step 2 Run the SET CLKMODE command to activate the GPS reference clock. Set the key parameters
according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


GPS(GPS Clock).

----End
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

51

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Configuring a Common BITS Reference Clock on the NodeB Side


Before configuring a common BITS reference clock, ensure that the NodeB has been configured
with a USCU board.
Step 1 Run the ADD BITS command to add a BITS clock link.
Step 2 Run the SET CLKMODE command to activate the BITS reference clock. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


BITS(BITS Clock).

----End

Configuring a Common E1/T1 Reference Clock on the NodeB Side


Before configuring a common E1/T1 reference clock, ensure that an E1/T1 clock link is
available.
Step 1 Run the ADD LINECLK command to add an E1/T1 clock link. In this step, set Port Type
(Port Type on the CME) to E1T1(E1T1).
Step 2 Run the SET CLKMODE command to activate the E1/T1 reference clock. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


LINECLK(Line
Clock).

----End

Configuring a Common IEEE 1588v2 Reference Clock on the NodeB Side


Step 1 Run the ADD IPCLKLINK command to add an IEEE 1588v2 clock link. Set the key parameters
according to the descriptions in the following table.
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

52

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Paramete
r Name

MML
Parameter ID

Paramete
r Name
on the
CME

Setting Notes

Protocol
Type

ICPT

Protocol
Type

Set this parameter to PTP(PTP).

Profile
Type

PROFILETYP
E

Profile
Type

Set this parameter to 1588V2(1588V2) or G.


8265.1(G.8265.1).
In most cases, set this parameter to 1588V2
(1588V2). If the IP clock server is a third-party
device, set this parameter to G.8265.1(G.
8265.1) to ensure the correct interworking
between the base station and the IP clock server.

Slot No.

SN

Slot No.

Set this parameter to the number of the slot that


accommodates the IP clock link.

Clock
Topology
Mode

CNM

Clock Net
Mode

Set this parameter to UNICAST(Unicast),


L3_MULTICAST(L3 Multicast), or
L2_MULTICAST(L2 Multicast).

Client IP

CIP

Client
IPv4

Set this parameter to the IPv4 address of the


client at the IP clock link.

Server IP

SIP

Server
IPv4

Set this parameter to the IPv4 address of the


server at the IP clock link.

NOTE

If the IEEE 1588v2 clock server and the NodeB are on different network segments, run the ADD IPRT
command to configure the route between the IEEE 1588v2 clock server and the NodeB.
The NodeB does not support IPV6.

Step 2 Run the SET CLKMODE command to activate the IEEE 1588v2 reference clock. Set the key
parameters according to the descriptions in the following table.

Issue 01 (2014-04-30)

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


IPCLK(IP Clock).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

53

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

IP Clock Time
Synchronization
Mode

SYNMODE

Synchronization
Mode

Set this parameter to


ABSOLUTE
(ABSOLUTE),
RELATIVE
(RELATIVE), or
OFF(OFF).

----End

Configuring a Common Synchronous Ethernet Reference Clock on the NodeB Side


Before configuring a common synchronous Ethernet reference clock, ensure that all transmission
equipment supports the synchronous Ethernet.
Step 1 Run the ADD SYNCETH command to add a synchronous Ethernet clock link. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates the
synchronous Ethernet
clock link.

Port No.

PN

Port No.

Set this parameter to


the number of the port
that accommodates the
synchronous Ethernet
clock link.

SSM Selection

SSM

Synchronization
Status Message

Set this parameter to


DISABLE
(DISABLE) or
ENABLE
(ENABLE).

Step 2 Run the SET CLKMODE command to activate the synchronous Ethernet reference clock. Set
the key parameters according to the descriptions in the following table.

Issue 01 (2014-04-30)

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

54

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


SYNCETH
(SyncEth Clock).

----End

Configuring a Common Reference Clock on the GBTS Side


Run the SET BTSCLK command with ClkType (on the CME name is Clock Type) set to
PEERCLK(Peer Clock).

Configuring a Common Reference Clock on the eGBTS/eNodeB/Co-MPT Base


Station side
Step 1 Run the ADD PEERCLK command to add a peer reference clock link.
Step 2 Run the SET CLKMODE command to configure the working mode of the reference clock.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


PEERCLK(Peer
Clock).

----End

9.4.3 The eNodeB Providing Clock Source for GBTS/eGBTS/


NodeB/Co-MPT Base Station
The configuration procedure involves configuring the reference clock on the eNodeB side and
Configuring a Common Reference Clock on the GBTS Side or Configuring a Common
Reference Clock on the eGBTS/NodeB/Co-MPT Base Station side. To configure a reference
clock on the eNodeB side, refer to one of the following sections:
l

Configuring a Common GPS Reference Clock on the eNodeB Side

Configuring a Common BITS Reference Clock on the FDD eNodeB Side

Configuring a Common E1/T1 Reference Clock on the FDD eNodeB Side

Configuring a Common IEEE 1588v2 Reference Clock on the eNodeB Side

Configuring a Common Synchronous Ethernet Reference Clock on the FDD eNodeB Side

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

55

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Configuring a Common GPS Reference Clock on the eNodeB Side


Step 1 Run the ADD GPS command to add a GPS clock link.
Step 2 Run the SET CLKMODE command to activate the GPS reference clock. Set the key parameters
according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


GPS(GPS Clock).

----End
NOTE

The eNodeB does not support switch between clock sources. Therefore, the System clock working
mode parameter must be set to MANUAL(Manual Handover).

Configuring a Common BITS Reference Clock on the FDD eNodeB Side


Before configuring a common BITS reference clock, ensure that the eNodeB has been configured
with a USCU board.
Step 1 Run the ADD BITS command to add a BITS clock link.
Step 2 Run the SET CLKMODE command to activate the BITS reference clock. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


BITS(BITS Clock).

----End

Configuring a Common E1/T1 Reference Clock on the FDD eNodeB Side


Before configuring a common E1/T1 reference clock, ensure that a UMPT board has been
configured and an E1/T1 clock link is available.
Step 1 Run the ADD LINECLK command to add an E1/T1 clock link. In this step, set Port Type
(Port Type on the CME) to E1T1(E1T1).
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

56

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Step 2 Run the SET CLKMODE command to activate the E1/T1 reference clock. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


LINECLK(Line
Clock).

----End

Configuring a Common IEEE 1588v2 Reference Clock on the eNodeB Side


Step 1 Run the ADD IPCLKLINK command to add an IEEE 1588v2 clock link. Set the key parameters
according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Protocol Type

ICPT

Protocol Type

Set this parameter to


PTP(PTP).

Profile Type

PROFILETYPE

Profile Type

Set this parameter to


1588V2(1588V2) or
G.8265.1(G.
8265.1).
In most cases, set this
parameter to 1588V2
(1588V2). If the IP
clock server is a
third-party device,
set this parameter to
G.8265.1(G.8265.1)
to ensure the correct
interworking
between the base
station and the IP
clock server.

Slot No.

Issue 01 (2014-04-30)

SN

Slot No.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

Set this parameter to


the number of the slot
that accommodates
the IP clock link.

57

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Clock Topology
Mode

CNM

Clock Net Mode

Set this parameter to


UNICAST
(Unicast),
L3_MULTICAST
(L3 Multicast), or
L2_MULTICAST
(L2 Multicast).

Client IP

CIP

Client IPv4

Set this parameter to


the IPv4 address of
the client at the IP
clock link.

Server IP

SIP

Server IPv4

Set this parameter to


the IPv4 address of
the server at the IP
clock link.

Client IPv6

CIPV6

Client IPv6

Set this parameter to


the client IPv6
address of the IP
clock link.

Server IPv6

SIPV6

Server IPv6

Set this parameter to


the server IPv6
address of the IP
clock link.

NOTE

If the IEEE 1588v2 clock server and the eNodeB are on different network segments, run the ADD IPRT
command to configure the route between the IEEE 1588v2 clock server and the eNodeB.

Step 2 Run the SET CLKMODE command to activate the IEEE 1588v2 reference clock. Set the key
parameters according to the descriptions in the following table.

Issue 01 (2014-04-30)

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


IPCLK(IP Clock).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

58

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

IP Clock Time
Synchronization
Mode

SYNMODE

Synchronization
Mode

Set this parameter to


ABSOLUTE
(ABSOLUTE),
RELATIVE
(RELATIVE), or
OFF(OFF).

----End

Configuring a Common Synchronous Ethernet Reference Clock on the FDD


eNodeB Side
Before configuring a common synchronous Ethernet reference clock, ensure that all transmission
equipment supports the synchronous Ethernet.
Step 1 Run the ADD SYNCETH command to add a synchronous Ethernet clock link. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates
the synchronous
Ethernet clock link.

Port No.

PN

Port No.

Set this parameter to


the number of the
port that
accommodates the
synchronous
Ethernet clock link.

SSM Selection

SSM

Synchronization
Status Message

Set this parameter to


DISABLE
(DISABLE) or
ENABLE
(ENABLE).

Step 2 Run the SET CLKMODE command to activate the synchronous Ethernet reference clock. Set
the key parameters according to the descriptions in the following table.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

59

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


SYNCETH
(SyncEth Clock).

----End

Configuring a Common Reference Clock on the GBTS Side


Run the SET BTSCLK command with ClkType (on the CME name is Clock Type) set to
PEERCLK(Peer Clock).

Configuring a Common Reference Clock on the eGBTS/NodeB/Co-MPT Base


Station side
Step 1 Run the ADD PEERCLK command to add a peer reference clock link.
Step 2 Run the SET CLKMODE command to configure the working mode of the reference clock.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


PEERCLK(Peer
Clock).

----End

9.4.4 Co-MPT Base Station Providing Clock Source for GBTS/


eGBTS/NodeB/eNodeB
This section describes how co-MPT multimode base stations provide the clock source for
separate-MPT multimode base stations in hybrid-MPT scenarios.
The configuration procedure involves configuring the reference clock on the co-MPT multimode
base station side and Configuring a Common Reference Clock on the GBTS Side or
Configuring a Common Reference Clock on the eGBTS/NodeB/eNodeB side. To configure
a reference clock on the co-MPT multimode base station side, refer to one of the following
sections:
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

60

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Configuring a Common GPS Reference Clock on the Co-MPT Base Station Side

Configuring a Common BITS Reference Clock on the Co-MPT Base Station Side

Configuring a Common E1/T1 Reference Clock on the Co-MPT Base Station Side

Configuring a Common IEEE 1588v2 Reference Clock on the Co-MPT Base Station
Side

Configuring a Common Synchronous Ethernet Reference Clock on the Co-MPT Base


Station Side

Configuring a Common GPS Reference Clock on the Co-MPT Base Station Side
Before configuring a common GPS reference clock, ensure that the co-MPT multimode base
station has been configured with a USCU board.
Step 1 Run the ADD GPS command to add a GPS clock link.
Step 2 Run the SET CLKMODE command to activate the GPS reference clock. Set the key parameters
according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


GPS(GPS Clock).

----End

Configuring a Common BITS Reference Clock on the Co-MPT Base Station Side
Before configuring a common BITS reference clock, ensure that the co-MPT multimode base
station has been configured with a USCU board.
Step 1 Run the ADD BITS command to add a BITS clock link.
Step 2 Run the SET CLKMODE command to activate the BITS reference clock. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


BITS(BITS Clock).

----End
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

61

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Configuring a Common E1/T1 Reference Clock on the Co-MPT Base Station Side
Before configuring a common E1/T1 reference clock, ensure that an E1/T1 clock link is
available.
Step 1 Run the ADD LINECLK command to add an E1/T1 clock link. In this step, set Port Type
(Port Type on the CME) to E1T1(E1T1).
Step 2 Run the SET CLKMODE command to activate the E1/T1 reference clock. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


LINECLK(Line
Clock).

----End

Configuring a Common IEEE 1588v2 Reference Clock on the Co-MPT Base Station
Side
Step 1 Run the ADD IPCLKLINK command to add an IEEE 1588v2 clock link. Set the key parameters
according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Protocol Type

ICPT

Protocol Type

Set this parameter to


PTP(PTP).

Profile Type

PROFILETYPE

Profile Type

Set this parameter to


1588V2(1588V2) or
G.8265.1(G.
8265.1).
In most cases, set this
parameter to 1588V2
(1588V2). If the IP
clock server is a
third-party device,
set this parameter to
G.8265.1(G.8265.1)
to ensure the correct
interworking
between the base
station and the IP
clock server.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

62

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates
the IP clock link.

Clock Topology
Mode

CNM

Clock Net Mode

Set this parameter to


UNICAST
(Unicast),
L3_MULTICAST
(L3 Multicast), or
L2_MULTICAST
(L2 Multicast).

Client IP

CIP

Client IPv4

Set this parameter to


the IPv4 address of
the client at the IP
clock link.

Server IP

SIP

Server IPv4

Set this parameter to


the IPv4 address of
the server at the IP
clock link.

Client IPv6

CIPV6

Client IPv6

Set this parameter to


the client IPv6
address of the IP
clock link.

Server IPv6

SIPV6

Server IPv6

Set this parameter to


the server IPv6
address of the IP
clock link.

NOTE

If the IEEE 1588v2 clock server and the co-MPT multimode base station are on different network segments,
run the ADD IPRT command to configure the route between the IEEE 1588v2 clock server and the coMPT multimode base station.

Step 2 Run the SET CLKMODE command to activate the IEEE 1588v2 reference clock. Set the key
parameters according to the descriptions in the following table.

Issue 01 (2014-04-30)

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

63

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


IPCLK(IP Clock).

IP Clock Time
Synchronization
Mode

SYNMODE

Synchronization
Mode

Set this parameter to


ABSOLUTE
(ABSOLUTE),
RELATIVE
(RELATIVE), or
OFF(OFF).

----End

Configuring a Common Synchronous Ethernet Reference Clock on the Co-MPT


Base Station Side
Before configuring a common synchronous Ethernet reference clock, ensure that all transmission
equipment supports the synchronous Ethernet.
Step 1 Run the ADD SYNCETH command to add a synchronous Ethernet clock link. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates
the synchronous
Ethernet clock link.

Port No.

PN

Port No.

Set this parameter to


the number of the
port that
accommodates the
synchronous
Ethernet clock link.

SSM Selection

SSM

Synchronization
Status Message

Set this parameter to


DISABLE
(DISABLE) or
ENABLE
(ENABLE).

Step 2 Run the SET CLKMODE command to activate the synchronous Ethernet reference clock. Set
the key parameters according to the descriptions in the following table.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

64

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


SYNCETH
(SyncEth Clock).

----End

Configuring a Common Reference Clock on the GBTS Side


Run the SET BTSCLK command with ClkType (the CME name is Clock Type) set to
PEERCLK(Peer Clock).

Configuring a Common Reference Clock on the eGBTS/NodeB/eNodeB side


Step 1 Run the ADD PEERCLK command to add a peer reference clock link.
Step 2 Run the SET CLKMODE command to configure the working mode of the reference clock.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


PEERCLK(Peer
Clock).

----End

9.4.5 Co-MPT Base Station Supporting Common Reference Clock


among GSM, UMTS, and LTE
A co-MPT multimode base station supports the Common Clock feature. For details about how
to configure a common GPS, BITS, E1/T1, IEEE1588V2, or synchronous Ethernet reference
clock, see section 9.4.4 Co-MPT Base Station Providing Clock Source for GBTS/eGBTS/
NodeB/eNodeB.

Configuring a Common 1PPS+TOD Reference Clock


Step 1 Run the ADD TOD command to add a 1PPS+TOD clock link.
Step 2 Run the SET CLKMODE command to activate the GPS reference clock. Set the key parameters
according to the descriptions in the following table.
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

65

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

System Clock
Working Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Clock Source Type

Set this parameter to


TOD(TOD Clock).

----End

Configuring a Common IEEE 1588v2+SyncE Reference Clock


Before configuring a common IEEE1588V2+SyncE reference clock, ensure that the
IEEE1588V2 IP clock server and the synchronous Ethernet share a clock source.
Step 1 Run the ADD SYNCETH command to add a synchronous Ethernet clock link. Set the key
parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates
the synchronous
Ethernet clock link.

Port No.

PN

Port No.

Set this parameter to


the number of the
port that
accommodates the
synchronous
Ethernet clock link.

SSM Selection

SSM

Synchronization
Status Message

Set this parameter to


DISABLE
(DISABLE) or
ENABLE
(ENABLE).

SyncEth Clock No.

LN

SyncEth Clock No.

Link No. 0 is
synchronousEthernet input and
link No. 1 is
synchronousEthernet output.

Step 2 Run the ADD IPCLKLINK command to add an IEEE 1588v2 clock link. Set the key parameters
according to the descriptions in the following table.
Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

66

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Protocol Type

ICPT

Protocol Type

Set this parameter to


PTP(PTP).

Profile Type

PROFILETYPE

Profile Type

Set this parameter to


1588V2(1588V2) or
G.8265.1(G.
8265.1).
In most cases, set this
parameter to 1588V2
(1588V2). If the IP
clock server is a
third-party device,
set this parameter to
G.8265.1(G.8265.1)
to ensure the correct
interworking
between the base
station and the IP
clock server.

Issue 01 (2014-04-30)

Slot No.

SN

Slot No.

Set this parameter to


the number of the slot
that accommodates
the IP clock link.

Clock Topology
Mode

CNM

Clock Net Mode

Set this parameter to


UNICAST
(Unicast),
L3_MULTICAST
(L3 Multicast), or
L2_MULTICAST
(L2 Multicast).

Client IP

CIP

Client IPv4

Set this parameter to


the IPv4 address of
the client at the IP
clock link.

Server IP

SIP

Server IPv4

Set this parameter to


the IPv4 address of
the server at the IP
clock link.

Client IPv6

CIPV6

Client IPv6

Set this parameter to


the client IPv6
address of the IP
clock link.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

67

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

Server IPv6

SIPV6

Server IPv6

Set this parameter to


the server IPv6
address of the IP
clock link.

NOTE

If the IEEE 1588v2 clock server and the co-MPT multimode base station are on different network segments,
run the ADD IPRT command to configure the route between the IEEE 1588v2 clock server and the coMPT multimode base station.

Step 3 Run the SET CLKMODE command to activate the IEEE 1588v2+SyncE reference clock. Set
the key parameters according to the descriptions in the following table.
Parameter Name

MML Parameter
ID

Parameter Name
on the CME

Setting Notes

System clock
working mode

MODE

Clock Working
Mode

Set this parameter to


MANUAL(Manual
Handover).

Selected Clock
Source

CLKSRC

Selected Clock
Source

Set this parameter to


SYNCETH
+IPCLK(SyncEth
Clock+IP Clock).

IP Clock Time
Synchronization
Mode

SYNMODE

Synchronization
Mode

Set this parameter to


ABSOLUTE
(ABSOLUTE),
RELATIVE
(RELATIVE), or
OFF(OFF).

----End

9.5 Activation Observation


Step 1 Run the GSM MML command LST BTSCLK and the co-MPT multimode base station/NodeB/
eNodeB/eGBTS MML command DSP CLKSTAT to check whether the Common Clock feature
has been activated.

Issue 01 (2014-04-30)

If...

Then...

The reference clock type is the same as the


preset one

Configuring the reference clock succeeds and


the feature has been activated.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

68

SingleRAN
Common Clock Feature Parameter Description

9 Engineering Guidelines

If...

Then...

The reference clock type is different from the


preset one

Configuring the reference clock fails and the


feature is not activated.

Step 2 Check whether any related alarms are generated.


If...

Then...

ALM-26276 Inter-System Site-Level


Configuration Conflict is generated and the
value of Configuration Item is Clock
Reference Type Configuration Conflict,
indicating a clock reference type
configuration conflict

Configuring the reference clock fails and the


feature is not activated.

----End

9.6 Troubleshooting
If ALM-26276 Inter-System Site-Level Configuration Conflict is generated, a clock reference
type configuration conflict occurs. That is, the base station of the current mode does not support
this type of reference clock. If this occurs, you must check the configuration file and correct the
clock reference type.
Alarm ID

Alarm Name

Configuration Item

26276

Inter-System Site-Level
Configuration Conflict

Clock Reference Type


Configuration Conflict

If the common reference clock is correctly configured but the base station cannot lock the clock
source within 30 minutes after it starts, you need to troubleshoot the common reference clock
fault. For details, see section "Troubleshooting" in Synchronization Feature Parameter
Description for GSM, UMTS, or LTE.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

69

SingleRAN
Common Clock Feature Parameter Description

10 Parameters

10

Parameters

Table 10-1 Parameter description


Parame
ter ID

NE

MML
Comma
nd

Feature
ID

Feature
Name

Description

MODE

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

SET
CLKM
ODE

MRFD210501

BTS
Clock

Meaning: Indicates the working mode of the system


clock. Manual indicates that a clock source must be
specified by the user. Auto indicates that the system
automatically selects a clock source based on the
priority and availability of the clock source. Free
indicates that the system clock works in free-running
mode, that is, the system clock does not trace any
reference clock source.

DSP
CLKST
AT
LST
CLKM
ODE

GUI Value Range: AUTO(Auto), MANUAL(Manual),


FREE(Free)
Unit: None
Actual Value Range: AUTO, MANUAL, FREE
Default Value: FREE(Free)

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

70

SingleRAN
Common Clock Feature Parameter Description

10 Parameters

Parame
ter ID

NE

MML
Comma
nd

Feature
ID

Feature
Name

Description

CLKSR
C

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

SET
CLKM
ODE

MRFD210501

BTS
Clock

Meaning: Indicates the type of the user-selected clock


source. The UMTS currently does not support "SyncEth
Clock+IP Clock" and "GPS Clock+SyncEth Clock"
function.

LST
CLKM
ODE

GUI Value Range: GPS(GPS Clock), BITS(BITS


Clock), IPCLK(IP Clock), SYNCETH(SyncEth
Clock), LINECLK(Line Clock), TOD(TOD Clock),
PEERCLK(Peer Clock), SYNCETH+IPCLK(SyncEth
Clock+IP Clock), GPS+SYNCETH(GPS Clock
+SyncEth Clock), INTERCLK(Inter Clock)
Unit: None
Actual Value Range: GPS, BITS, IPCLK, SYNCETH,
LINECLK, TOD, PEERCLK, SYNCETH+IPCLK,
GPS+SYNCETH, INTERCLK
Default Value: GPS(GPS Clock)

ICPT

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
IPCLKL
INK
LST
IPCLKL
INK

WRFD050501

Clock
Sync on
Ethernet
in
NodeB

Meaning: Indicates the type of the IP clock protocol,


which can be PTP or Huawei proprietary protocol. PTP
includes IEEE1588 V2, G.8265.1 and 1588V2_16.1.
IEEE1588 V2, defined by the IEEE, supports both time
synchronization and frequency synchronization. G.
8265.1 supports frequency synchronization only. 1588
V2_16.1 supports both time synchronization and
frequency synchronization. Huawei proprietary
protocol, which is the Huawei-defined IP clock
protocol, applies to the interconnection between
Huawei equipment and supports frequency
synchronization only.
GUI Value Range: HW_DEFINED(HuaWei Defined
Protocol), PTP(PTP Protocol)
Unit: None
Actual Value Range: HW_DEFINED, PTP
Default Value: PTP(PTP Protocol)

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

71

SingleRAN
Common Clock Feature Parameter Description

10 Parameters

Parame
ter ID

NE

MML
Comma
nd

Feature
ID

Feature
Name

Description

PROFIL
ETYPE

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
IPCLKL
INK

WRFD050501

Clock
Sync on
Ethernet
in
NodeB

Meaning: Indicates the type of protocol supported by


the IEEE 1588 V2-compliant IP clock link, which can
be ITU-T G.8265.1, IEEE 1588 V2 or
IEEE1588V2_16.1. ITU-T G.8265.1 is defined by the
International Telecommunication Union (ITU) for
frequency synchronization of an IEEE 1588 V2compliant IP clock link with the networking type of
UNICAST. An IP clock link in compliant with ITU-T
G.8265.1 supports interconnection with servers from
other vendors. An IP clock link in compliant with IEEE
1588 V2 supports interconnection with servers from
other vendors only in L2 or L3 multicast networking.
IEEE1588V2_16.1 can also be used for interconnection
with servers from other vendors when the other vendors
do not support ITU-T G.8265.1.The contentS of
IEEE1588V2_16.1 refers to the optional section 16.1 of
IEEE1588V2 protocol.

LST
IPCLKL
INK

GUI Value Range: 1588V2(1588V2), G.8265.1(G.


8265.1), 1588V2_16.1(1588V2_16.1)
Unit: None
Actual Value Range: 1588V2, G.8265.1, 1588V2_16.1
Default Value: 1588V2(1588V2)
SN

CNM

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
IPCLKL
INK

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
IPCLKL
INK

None

None

Meaning: Indicates the number of the slot where the IP


clock link is configured.
GUI Value Range: 0~7

LST
IPCLKL
INK

Unit: None
Actual Value Range: 0~7
Default Value: 7

LST
IPCLKL
INK

WRFD050501

Clock
Sync on
Ethernet
in
NodeB

Meaning: Indicates the networking type for the IP clock.


The LTE currently does not support L3 Multicast
function.
GUI Value Range: UNICAST(Unicast),
L3_MULTICAST(L3 Multicast), L2_MULTICAST
(L2 Multicast)
Unit: None
Actual Value Range: UNICAST, L3_MULTICAST,
L2_MULTICAST
Default Value: UNICAST(Unicast)

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

72

SingleRAN
Common Clock Feature Parameter Description

10 Parameters

Parame
ter ID

NE

MML
Comma
nd

Feature
ID

Feature
Name

Description

CIP

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
IPCLKL
INK

WRFD050501

Clock
Sync on
Ethernet
in
NodeB

Meaning: Indicates the client IPv4 address of the IP


clock link.

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
IPCLKL
INK

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

SET
CLKM
ODE

SIP

SYNM
ODE

DSP
IPCLKL
INK

GUI Value Range: Valid IP address


Unit: None
Actual Value Range: Valid IP address
Default Value: 0.0.0.0

LST
IPCLKL
INK
WRFD050501

LST
IPCLKL
INK

Clock
Sync on
Ethernet
in
NodeB

Meaning: Indicates the server IPv4 address of the IP


clock link.
GUI Value Range: Valid IP address
Unit: None
Actual Value Range: Valid IP address
Default Value: 0.0.0.0

WRFD050501

LST
CLKM
ODE

Clock
Sync on
Ethernet
in
NodeB

Meaning: Indicates the mode of scheduled


synchronization for the IP clock link. In ABSOLUTE
mode, the system clock obtains synchronization signals
from the clock server at a fixed time every day until the
system clock is stable. In RELATIVE mode, the system
clock obtains synchronization signals from the clock
server at regular intervals until the system clock is
stable. In OFF mode, the system clock obtains only
messages from the clock server in real time. The LTE
currently does not support this function.
GUI Value Range: ABSOLUTE(ABSOLUTE),
RELATIVE(RELATIVE), OFF(OFF)
Unit: None
Actual Value Range: ABSOLUTE, RELATIVE, OFF
Default Value: OFF(OFF)

SN

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

Issue 01 (2014-04-30)

ADD
SYNCE
TH
LST
SYNCE
TH

None

None

Meaning: Indicates the number of the slot where the


synchronous-Ethernet clock link is configured.
GUI Value Range: 0~7
Unit: None
Actual Value Range: 0~7
Default Value: 7

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

73

SingleRAN
Common Clock Feature Parameter Description

10 Parameters

Parame
ter ID

NE

MML
Comma
nd

Feature
ID

Feature
Name

Description

PN

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
SYNCE
TH

WRFD050502

Clock
Sync on
Ethernet

Meaning: Indicates the number of the port where the


synchronous-Ethernet clock link is configured.

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
SYNCE
TH

SSM

LST
SYNCE
TH

Unit: None
Actual Value Range: 0~5
Default Value: 0
WRFD050502

Clock
Sync on
Ethernet

MOD
SYNCE
TH
DSP
SYNCE
TH

SIPV6

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
IPCLKL
INK

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
IPCLKL
INK

Unit: None

Issue 01 (2014-04-30)

Actual Value Range: DISABLE, ENABLE


Default Value: DISABLE(DISABLE)
WRFD050501

DSP
IPCLKL
INK

Clock
Sync on
Ethernet
in
NodeB

Meaning: Indicates the client IPv6 address of the IP


clock link. The UMTS currently does not support this
function.
GUI Value Range: Valid IP address
Unit: None
Actual Value Range: Valid IP address

LST
IPCLKL
INK

LST
IPCLKL
INK

Meaning: Indicates whether handling of SSM frames is


supported.The setting of this parameter is consistent
with the setting on the Ethernet clock server. The
synchronization status message (SSM) carries clock
quality information, which is specified in ITU-T. This
parameter is valid only when the synchronous-Ethernet
clock link is of the input type.
GUI Value Range: DISABLE(DISABLE), ENABLE
(ENABLE)

LST
SYNCE
TH
CIPV6

GUI Value Range: 0~5

Default Value: 0:0:0:0:0:0:0:0

WRFD050501

Clock
Sync on
Ethernet
in
NodeB

Meaning: Indicates the server IPv6 address of the IP


clock link. The UMTS currently does not support this
function.
GUI Value Range: Valid IP address
Unit: None
Actual Value Range: Valid IP address
Default Value: 0:0:0:0:0:0:0:0

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

74

SingleRAN
Common Clock Feature Parameter Description

10 Parameters

Parame
ter ID

NE

MML
Comma
nd

Feature
ID

Feature
Name

Description

LN

BTS390
0,
BTS390
0
WCDM
A,
BTS390
0 LTE

ADD
SYNCE
TH

WRFD050502

Clock
Sync on
Ethernet

Meaning: Indicates the number of the synchronousEthernet clock link. A maximum of two links can be
configured currently.

DSP
SYNCE
TH
MOD
SYNCE
TH

GUI Value Range: 0~1


Unit: None
Actual Value Range: 0~1
Default Value: 0

RMV
SYNCE
TH
LST
SYNCE
TH

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

75

SingleRAN
Common Clock Feature Parameter Description

11 Counters

11

Counters

There are no specific counters associated with this feature.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

76

SingleRAN
Common Clock Feature Parameter Description

12 Glossary

12

Glossary

For the acronyms, abbreviations, terms, and definitions, see the Glossary.

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

77

SingleRAN
Common Clock Feature Parameter Description

13

13 Reference Documents

Reference Documents

1.

Common Transmission Feature Parameter Description for SingleRAN

2.

Synchronization Feature Parameter Description for GSM BSS, WCDMA RAN, and
eRAN

Issue 01 (2014-04-30)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

78