Sei sulla pagina 1di 8

*=*=*=*=*=*=*=*=*=*=*=*=*=*=*

*=*=*=*=*=*=*=*=*=*=*=*=*=*=*

DESIGN OF R.C.C.

CAPACITY-

G.S.R.

40.00 Kilolitres

AT - RWSS JHADOL.

DISTRICT - UDAIPUR.

*=*=*=*=*=*=*=*=*=*=*=*=*=*=*
*=*=*=*=*=*=*=*=*=*=*=*=*=*=*

DESIGN OF TOP DOME (M-30)


=========================
DIAMETER OF TANK(D) =

4.800 metres

RISE OF DOME (h1) =

0.800 metres

RADIUS OF DOME(R1) =

4.000 metres

ASSUME TH.OF DOME

(t1) =

0.150 metres

ANGLE (x1)=SIN^-1(D/2R1) = 0.643501 radians


(x1) = 36.86989 degrees
LIVE LOAD ON TOP DOME =

4000 Newtons/sqm.

UNIT WEIGHT OF WATER =

9800 N/cum.

UNIT WEIGHT OF CONCRETE =

25000 N/cum.

U.D.L.PER sqm.OF SURFACE AREA


DUE TO SELF WT.( 25000*t1 ) =

3750 N/sqm.

U.D.L.PER sqm.OF SURFACE AREA


DUE TO SELF WT.& LIVE (25000*t1+L) =

7750 N/sqm.

7750

Less than 51.8 Degree


so O.K.

MAXIMUM MERIDIONAL STRESS, i.e. AT SPRINGINGS =


4 /
150 )/(
0.8 + 1) / 1000

0.1148 N/sqmm.
(COMP) SAFE

MAXIMUM HOOP STRESS i.e. AT THE TOP OF THE DOME =


(
7750 *
4 /
150 / 2 / 1000)

0.1033 N/sqmm.
(COMP) SAFE

MINIMUM AREA OF STEEL REQUIRED @


0.24 /
100 *
150
*
USING 8 mm. DIA BARS
PI / 4 * 8 ^2 * 1000 /
PROVIDE 8 mm.DIA BARS@
AND HOOP BARS AT EDGES

0.2400 % =
1000

SPACING REQUIRED
=
360
SAY

360 sqmm.
140 mm. c/c.
130 mm. c/c.

130 mm c/c BOTH WAYS IN THE FORM OF MESH.


3 Nos

8 mm. DIA IN A LENGTH OF

800 mm.
EXTEND THE VERTICAL BARS OF THE WALL IN THE DOME FOR A DISTANCE

***************

800 mm.

DESIGN OF TOP RING BEAM (M-30)


==============================
(

MAX MERIDIONAL STRESS IN TOP DOME i.e. AT SPRINGINGS


7750 *
4 /
150 )/(
0.8 + 1) / 1000

THICKNESS OF DOME

0.150 mt.

MERIDIONAL THRUST PER m. LENGTH OF DOME AT ITS BASE


0.1148 *
150
*
1000

17220 N/m.

HORIZONTAL COMPONENT PER m. LENGTH


17220 *
0.8

13776 N/m.

HOOP TENSION TRYING TO RUPTURE THE BEAM


13776 *
4.800
/
2

33062 N.

AREA OF STEEL REQUIRED


33062
/
130

254 sqmm.

- 10 mm. BARS,AREA OF STEEL PROVIDED


4 * PI / 4 *
10 *
10

314 sqmm.
254 O.K.

AREA OF CONCRETE REQUIRED


1.5 ) - (9 - 1) *
314

IF USING

Nos.

33062

PROVIDE RING BEAM


PROVIDE

33062 / (

mm.

DIA

250

250

mm. WIDE

STIRRUPS

0.1148 N/sqmm.

>

19529 sqmm.

150 mm.DEEP.

300 mm c/c TO TIE THE HOOP BARS

STRESS IN CONCRETE OF RING BEAM =


0.8263 N/sqmm.
150 + ( 9 - 1 ) *
314 ) (TENSILE) SAFE

DESIGN OF TANK WALL (M-30)


==========================
DIAMETER OF TANK

4.800 mt.

HEIGHT OF TANK WALL

2.550 mt.

FREEBOARD

0.300 mt.

Ht. OF TANK WALL AVAILABLE FOR WATER COLUMN


2.550 0.300

2.250 mt.

NET CAPACITY OF TANK


4.800 *
2.25

40.72 K.L.

GROSS CAPACITY OF TANK


PI / 4 *
4.800 ^2*
0.300

46.15 K.L.

MAXIMUM HOOP TENSION AT THE BASE


2.550 *
4.8 / 2

59976 N/m

PI/4 *
40.72
9800

4.800

AREA OF HOOP RINGS REQUIRED


59976
/
130

TAKING MAXIMUM ALLOWABLE TENSILE STRESS IN CONCRETE

THICKNESS REQUIRED TO RESIST HOOP TENSION


1.50 - ( 9 - 1 ) *
461 ) / 1000

36 mm.

AVERAGE THICKNESS OF THE WALL =


200 +
200 ) / 2
H^2/D.t =
2.550 /
4.800 /
0.200

200 mm.

59976

HOWEVER PROVIDE

461 sqmm./m.
1.50 N/sqmm.

200 mm. THICKNESS THROUGHT THE HEIGHT.


(
2.550

6.77

CALCULATION OF HOOP REINFORCEMENT AT DIFFERENT HEIGHTS IN WALL


================================================================================
DEPTH
WALL
VALUE
HOOP
TOTAL AREA OF STEEL REQD. DIA OF
SPACING
OF WALL
THICK- OF HOOP FORCE
------------------------- HOOP BARS PROVIDED
BELOW TOP NESS AT FORCE
TO
MINIMUM MAXIMUM PROVIDED
LOWER
COEFFIRESIST TEMPERA OF TWO
END
CIENT
HOOP
-TURE
VALUES
FORCE
STEEL
(m)
mm.
N/m.
sqmm.
sqmm.
sqmm.
mm.
mm c/c.
-------------------------------------------------------------------------------0.20 H
200
0.2172
13027
100
480
480
8
100
0.40 H

200

0.4553

27307

210

480

480

100

0.60 H

200

0.6475

38834

299

480

480

100

0.80 H

200

0.5755

34516

266

480

480

100

1.00 H
200
0.3497
20974
161
480
480
8
100
================================================================================
HOOP FORCE CALCULATIONS ARE AS PER TABLE - 12 OF IS-3370-1967 PART - IV.
MAX. B.M. AT THE BASE AS PER TABLE 10 OF IS-3370-1967 PART 4 =
0.0171 *
9800 *
2.550 ^3
THICKNESS REQUIRED FROM BENDING MOMENT POINT OF VIEW =
( 6 *
2779 /
2.000 )^0.5
PERCENTAGE OF MIN. STEEL REQUIRED

MINIMUM AREA OF STEEL REQUIRED ON EACH FACE


0.24 *
200 * 1000 / 100 / 2

AREA OF STEEL REQUIRED TO RESIST BENDING MOMENT =


/
130 / 0.863636 / (
200 8 / 2

2779000

IF USING 8 mm DIA BARS, SPACING OF BARS REQUIRED


PI/4 * 8 *
8 * 1000 /
240

2779 Nm/m.
91 mm.
O.K.
0.24 %
240 sqmm.

138 sqmm.
40)
209 mm c/c

ON INNER FACE PROVIDE 8 mm. DIA VERTICAL BARS

200 mm c/c THROUGHOUT.

ON OUTER FACE PROVIDE 8 mm. DIA VERTICAL BARS

200 mm c/c THROUGHOUT.

MINIMUM AREA OF STEEL REQUIRED AT TOP


1000 *
200 *
0.24 / 100

434 sqmm.

AREA OF STEEL PROVIDED AT TOP


+
8 ^2) * 1000/
200

503 sqmm.
O.K.

PI/4 * ( 8 ^2

MAXIMUM HOOP STRESS IN THE WALL =


0.1903 N/sqm.
200 *1000 + (9-1) *
503 ) (TENSILE) SAFE

38834 / (

MAXIMUM BENDING STRESS IN THE WALL


6 *
2779 /
200 /
200

0.4169 N/sqm.
SAFE

DESIGN OF BASE SLAB (M-30)


==========================
BEARING CAPACITY OF THE SOIL =

80.00 K-N/sqm.

INTENSITY OF LOAD ON THE SOIL =

27.05 K-N/sqm.
SAFE

The base slab is resting directly on ground, as such, transferring the


load of water and self weight directly. At edges the thickness of base slab
shall

be

kept

equal

to

200 mm.which will be reduced to

Minimum reinforcement required @ 0.24 % =


Use

8 mm. dia bars

In the
provide
For

portion
8

resisting

of

the
Nos

bending

240 sqmm.

100 mm. c/c. both ways in the base slab.

slab near the

wall (i.e.

200 mm. thick)

8 mm. dia hoop bars.


moment

8 mm. dia alternate bars @

at

the

wall base provide

radially upto a distance of

200 mm. c/c and extend

0.500 m. depth.

*********************

&

them in the slab

0.900 m.

The CWR will be in the ground upto

8 mm.dia

SCHEDULE - "G"
==============
Rates are based on Integrated PWD BSR Jan'2005.
40 K.L. - GSR
==============================================================================
S.NO.
PARTICULARS
QUANTITY
UNIT
RATE
AMOUNT
( Rs.)
( Rs.)
-----------------------------------------------------------------------------1. B-2/1.8
------Earthwork in excavation in
foundation trenches or drains
including dressing of sides and
ramming of bottoms,lift upto
1.50 Mt including taking out
excavated soil and depositing
and refilling of jhiri with
watering and ramming and
disposal of surplus excavated
soil as directed within a lead
of 50 Mt. All kinds of soil.
14.16
Cum.
38.00
538.08
2.

3.

4.

B-14/3.2.3
---------Providing & laying cement conc.
including curing,compaction etc.
complete in specified grade
excl. cost of centring & shuttering. All work upto plinth level
1:2:4 (1 cement : 2 course sand :
4 graded stone aggregate 20 mm)

1.85

Cum.

1530.00

2830.50

B-18/4.1.1
---------Providing & laying in position
specified grade of RCC incl.
curing, compaction, finishing with
rendering in cement sand mortar
1:3 (1 cement : 3 coarse sand
and making good the Joints excl.
the cost of centring and shuttering
and reinforcement. All work upto
plinth level 1 : 1 : 2
(1 cement : 1 coarse sand : 2
graded stone aggregate 20 mm.
nomonal size.

3.79

Cum.

2165.00

8205.35

B-18/4.2.1
---------Reinforced cement concrete work in
walls,pilasters,buttresses,plinth
and string courses,fillets, columns
pillars, piers etc upto floor three
level, incl. curing compaction,
finishing with rendering in cement
sand mortar 1:3 & making good the
joints exl. cent & shutt - 1:1:2

8.6

Cum.

2260.00

19436.00

Rates are based on Integrated PWD BSR Jan'2005.


40 K.L. - GSR
==============================================================================
S.NO.
PARTICULARS
QUANTITY
UNIT
RATE
AMOUNT
( Rs.)
( Rs.)
-----------------------------------------------------------------------------5. B-19/4.5
-------Reinforced concrete work in arches,
arch ribs,domes & vaults etc.----in
1:1.5:3 grade
2.93
Cum. 1932.00
5660.76
6.

7.

8.

9.

B-22/4.13.2
----------Providing and fabricating
steel reinforcement for
R.C.C. work including
cutting, bending,placing
in position and binding
comp. including cost of
binding wire) all comp.
upto floor three level
Cold twisted deformrd
bars (IS:1786)

719

Kg.

31.00

22289.00

3.52

Sqm.

53.00

186.56

B-20/4.12.1
----------Walls (any thickness) including
attached pillasters, buttresses
plinth & string courses.

85.69

Sqm.

64.00

5484.16

--do-B-21/4.12.5
----------Arches, domes, vaults
upto 6 Mtr. span.

20.11

Sqm.

130.00

2614.30

B-20/4.11
--------Centring & shuttering with
plywood or steel sheets including
strutting,propping,bracing bothways
and removal of formwork for foundations in basements rafts, footings,
strap beams, bases of columns, etc
upto plinth level.
Centring and shuttering with
plywood or steel sheets including struting,propping,bothways with wooden member and
removal of formwork for
superstructure upto 4.5 m.
height above plinth level
for :

etc.

Rates are based on Integrated PWD BSR Jan'2005.


40 K.L. - GSR
==============================================================================
S.NO.
PARTICULARS
QUANTITY
UNIT
RATE
AMOUNT
( Rs.)
( Rs.)
-----------------------------------------------------------------------------10. B-21/4.12.12
-----------Add extra for shuttering in
circular work in plan upto
dia 10 m.over item Nos.4.12.1
89.21
Sqm.
16.00
1427.36
to 4.12.3
11. B-90/9.19
--------Providing & fixing steel gate
grating & grills made of angles,
tees, square bars or other flats
black pipe with hold fast and fittings complete as per design and
drawing including cutting and welding
and fabrication with priming coat
of red oxide.

54.74

Kg.

37.00

2025.38

12. B-94/9.31
--------Supplying & fixing fixed wire
gauge of 14 mesh x 24 gauge to the
metal frame of rolled section by
metal beading 20x3 mm with suitable
screw at not exceeding 150 mm
distance.

0.94

Sqm.

285.00

267.90

13. B-87/9.22.3
----------Providing and fixing 1 mm thick M.S.
sheet garrage door shutter with frame
of 40x40x6 mm angle iron 3 mm M.S.
gusset plates at the junctions and
corners including all fittings and
applying a coat of approved steel
primer. Using flats 30x6 mm for
diagonal braces and central cross
piece.

0.64

Sqm.

710.00

454.40

14. B-96/9.44
--------Providing & fixing MS round holding
bolts with nuts and washers complete

4.00

Kg.

30.00

120.00

15. Fixing inlet,outlet,


overflow & washout pipes.

- L.S.

8000.00

16. Providing and fitting water gauge


- L.S. 4000.00
-----------------------------------------------------------------------------Total - 83539.75
==============================================================================