Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Interconnection
between
AC System
Frequency
AC System
Voltage
Power Co.
400 kV
90 kV
ENEL (Ente Nazionale per 1Engia Elettrica)
Rome and EDF (Electricite de France)
Manufacturer
Commissioned
Main Purpose
Main Data
400 kV
Lucciana:
CGEE.ALSTHOM and ALSTHOM ATLANTIQUE subcontractor, France.
Codrongianos and Suvereto: July 1992
Lucciana: October 1985
Frequency support to the Sardinian A.C. network by power/frequency control of the
D.C. line.
In Corsica, energy supply, frequency control and static "spinning reserve". The
direction of the power flow between the two main stations Codrongianos and
Suvereto, imposes the polarity of the D.C. line voltage. The direction of the flow on
the A.C. Corsican network is made independent of this polarity by reversing the
connection of the Corsican converters by high-speed isolating switches.
Automatic power reversal between the main stations is still possible by a sequence
eliminating Corsican converters for 500 ms.
The three stations are connected in parallel on a line which is operated at the rated
voltage + 200 kV; earth and sea return are used.
Codrongianos: 300 MW at + 200 kV D.C. and 1500 A. Anode situated on the
Sardinian coast.
Suvereto: 300 MW, at + 200 kV D.C. and 1500 A. Cathode situated on the coast.
Lucciana: 50 MW, at + 200 kV D.C. and 250 A. Earth electrode on the shore used as
an anode or a cathode.
A.C. Networks
At both terminals three single phase converter transformers for a 12-pulse converter are used.
There is one spare unit at Suvereto. In Corsica, three single-phase transformers supplies one
12-pulse converter.
At Suvereto and Codrongianos terminals the windings on the 400 kV A.C. side are star
connected while the windings on the valve side are one star and the other delta connected.
Converter Transformer Ratings
HVDC System
Suvereto
Codrongianos
Lucciana
25/12.5/12.5 MVA
90 + 10%/105.7/105.7:
3 kV.
Min. short circuit
capacity: 120 MVA.
The windings on the 90
kV network side are star
connected, while the
windings on the valve
side are one star and the
other delta connected.
Italian coast.
On Sardinia, the electrode line is designed as a separate overhead line to the anode location
about 30 km from the converter station.
Submarine
Cable
Electrodes
A.C. Filters
The Corsica earth electrode line is designed as a conventional 20 kV line but with 2
conductors.
The two submarine cables used are both solid type with oilfilled paper insulation and a Cuconductor of 420 mm2. The cables are armoured by a single layer of steel wires with a
diameter of 7 mm.
Italian Mainland-Corsica: length = 105 km
Corsica-Sardinia: length = 16 km
In Sardinia the anode electrode station is designed as a sea electrode with 30 electrodes
arranged in a little quiet bay, protected from the sea by a concrete break-water. The single
electrode is made of platinum coated titanium pipe with cable connections to a busbar.
Total resistance = 0.6 ohm (including cable connections)
In Corsica, the earth electrode1 acting as an anode or a cathode, is located 9 km from the
converter station, near the sea.
It consists of a line of 50 ferro-silicium-chrome electrodes, placed horizontally every 5
meters.
Total resistance: 0.16 ohm
Harmonic filters are provided at each of the three terminals:
Suvereto: Total installed: 76 MVAr
Harm
MVAr
C= F
L=mH
R=
12a
23a
48
28
0.948
0.556
74.2
34.4
2238
523
MVAr
C= F
L=mH
R=
12a
55
1.087
64.7
1953
23a
40
0.794
24.1
364
Lucciana: Total installed 5 filters each 10 MVAr of the damped type designed as 3 Combined
filters for 5a and 7a harm and 2 combined filters for 11a and 13a harm. Each with
DC Filters
C= F
C1= F
L1=mH
L2=mH
R1=
R2=
3.784
4.73
82.2
18.5
3.30
146.2
At both main stations, D.C. filters are used for 600 and 1200 Hz harmonics.
In Corsica, there are no D.C. filters
HVDC Valves
Valve Cooling
The valves are cooled by deionised water circulated in a closed loop system.
The heat is transferred to a secondary circuit which is cooled in outdoor coolers.
D.C. Reactor
References
System
correspondent
Mr Alberto GIORGI
ENEL
Direzione della Produzione e Transmissione
Via G. Fattori, 10/c
50132 Firenze
ITALY
Telephone + 39 55 6554101
Telefax + 39 55 6554130