Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
more than 500 people around the world, 400 in Germany alone.
In addition to the production locations in Unterbhringen and Shanghai/China, 15 subsidiaries and other sales partners in Germany and abroad work for our international
success on the market.
We take the technological and ecological challenges of the future as an incentive for
extraordinary product developments.
EUCHNER safety switches monitor safety doors on machines and installations, help to
minimize dangers and risks and thereby reliably protect people and processes. Today,
our products range from electromechanical and electronic components to intelligent
integrated safety solutions. Safety for people, machines and products is one of our
dominant themes.
We dene future safety technology with the highest quality standards and reliable
technology. Extraordinary solutions ensure the great satisfaction of our customers.
The product ranges are subdivided as follows:
Transponder-coded Safety Switches (CES)
Transponder-coded Safety Switches with guard locking (CET)
Interlocking and guard locking systems (Multifunctional Gate Box MGB)
Access management systems (Electronic-Key-System EKS)
Electromechanical Safety Switches
Magnetically coded Safety Switches (CMS)
Enabling Switches
Safety Relays
Emergency Stop Devices
made
in
Germany
2
Contents
Non-contact safety system CES
The system
9
10 - 13
14
20
30
39
43
52
54
57
64
73
77
78 - 81
82
84
86
91
94 - 97
98
101
103
107
110 - 113
114
117
120
221
225
Item index
Index by item designation
Index by order number
237
237
241
076649-18-11/13
The System
The advantages of the CES system at a glance
f
f
f
f
f
f
f
f
f
f
Coded actuator
Read head
Evaluation unit
In some systems, the read head and evaluation unit form a sealed unit. In
this case the term safety switch is used, as all safety functions are integrated into one component (see section on safety switches further down).
General information
Coded actuator
Safety switch (read head with integrated evaluation)
Coded actuators
Each actuator supplied has a unique code and is therefore a unique element. The code in an actuator cannot be reprogrammed.
Read heads
The read head is fastened to the xed part of the safety guard and is connected to the evaluation unit via a two-core screened cable. The actuator
fastened to the safety guard is moved towards the read head by closing
the door. When the switch-on distance is reached, power is supplied to
the actuator via the read head and the read head transfers the actuator's
data to the evaluation unit.
Actuator and read head have a wide operating distance and a broad hysteresis. Misalignment of the door will therefore not result in the system
switching off unintentionally. If the actuator is positioned exactly at the
limit of the switch-on distance, vibration at the safety guard will not cause
the machine to stop unintentionally.
EUCHNER provides read heads in a very wide range of designs with and
without guard locking (see next section).
Read heads with guard locking
Guard locking is a feature that prevents the unintentional opening of a
door as long as there is a hazard. For this purpose, EUCHNER has read
heads with guard locking in its range. They function like any other CES
read head, but also contain a guard locking mechanism. Depending on
the read head series and the evaluation unit used, varying levels of safety
can be achieved. You will nd exact information on the level of safety that
can be achieved in the combination tables for each product.
Evaluation units
CES evaluation units combine transponder evaluation and a safety relay
in one device.
The read head is connected to the CES evaluation unit. This unit checks
the actuator's bit pattern. The data transmission from the read head
to the evaluation unit is dynamic and single-channel. All potential faults
(e.g. broken cable, short circuit, failure of the actuator, etc.) are reliably
detected. The number of read heads that can be connected depends on
the evaluation unit.
The evaluation units have enable paths with which devices such as relays or
contactors can be switched. If the evaluation unit detects a valid actuator,
the evaluation unit closes its enable paths.
How the evaluation is performed in detail depends on whether the evaluation unit is a unicode or multicode evaluation unit.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
The System
Approvals
Unicode evaluation
With the unicode version, the actuators must be taught-in on the evaluation
unit. During teach-in the actuator code is assigned to the evaluation unit.
This code is saved in the evaluation unit. Whenever an actuator is read,
the evaluation unit compares the code just read with the code saved.
Only if the two bit patterns are identical, the actuator is recognized and
the enable paths are closed. The number of possible teach-in operations
is dependent of the evaluation unit used. Only the last actuator taught-in
is detected. The unicode principle provides a high level of protection
against tampering.
Fixcode evaluation
In case of xcode devices, the teach-in operation is performed prior to
delivery at EUCHNER. An actuator is permanently assigned to the device
in this process. The device can be operated only with this one actuator.
No additional actuators can be taught-in.
Multicode evaluation
Unlike systems with unique code detection, with multicode evaluation a
specic actuator code is not requested, instead it is only checked whether
the actuator is of a type from EUCHNER that can be detected by the system
(multicode detection). There is no exact comparison of the actuator code
with the code saved in the evaluation unit. As a result a teach-in operation
for the actuator is not necessary.
Devices with this symbol are approved by Underwriters Laboratories (UL, Canada and USA)
Safety switches
On the safety switches, read head and evaluation unit are integrated into
one housing. Their principle of operation does not differ from other CES
systems. The safety switches are also available in unicode, multicode and
xcode versions. The advantage compared to evaluation with a separate
evaluation unit is in the combination of the complete switch function in
one compact housing. This feature makes possible decentralized evaluation directly on-site.
External
clock signals
allowed
Short circuit
monitoring
(own clock signal)
Switch chain
Feedback loop
Monitored
Start button
Guard lock
monitoring
System family
Guard locking
Interlocking
CES-AP-
Safety switches
CET-AP-
CES-AR-
Max. 20
devices
Safety switches
CET-AR-
Key to symbols
Option available
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
The System
Explanation of symbols
Connection options
1...2
1...4
1...20
Components
Evaluation unit
Actuator CES
Cat.
3
PLd
Cat.
3
PLe
Cat.
3/4
PLe
Connection cables
Cat.
4
PLe
C01
Plug connectors
Guard locking for personal protection
M8
5
pin
Miscellaneous
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
The System
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
The System
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
The CES evaluation units have two enable paths and monitoring outputs
for each read head connected. The devices have additional monitoring
outputs, as well as connections for a monitored start button and feedback
loop.
Start button
Evaluation units with a connection for a Start button permit a monitored,
manual start. The relays in the evaluation unit are started by pressing
a button. The button is monitored for jamming or possible tampering
(monitoring of the falling edge).
Feedback loop
Components connected downstream of the evaluation unit can be monitored for correct function. For this purpose normally closed contacts on
these components are integrated into the feedback loop on the evaluation unit. Only if the feedback loop is connected (Y1/Y2) can the safety
outputs be switched.
Guard lock monitoring with the safety system CES-AZ
In principle a read head with guard locking can be connected to each CES
evaluation unit. Evaluation units in the system family CES-AZ- monitor
the guard locking in accordance with EN 1088. For information on which
device combination can be used as guard locking in accordance with
EN 1088, please refer to the related product page and the combination
tables. Previous versions of the system family CES-A- do not provide
safe guard lock monitoring.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-AZ
CES-AZ-AES-01B / CES-AZ-UES-01B
f 1 read head
f Category 4 according to EN ISO 13849-1
f PL e according to EN ISO 13849-1
f Available in the unicode and multicode variants
(see page 14)
1...2
Cat.
4
PLe
CES-AZ-AES-02B / CES-AZ-UES-02B
f Up to 2 read heads
f Category 4 according to EN ISO 13849-1
f PL e according to EN ISO 13849-1
f Available in the unicode and multicode variants
(see page 16)
1...4
Cat.
4
PLe
10
CES-AZ-AES-04B / CES-AZ-UES-04B
f Up to 4 read heads
f Category 4 according to EN ISO 13849-1
f PL e according to EN ISO 13849-1
f Available in the unicode and multicode variants
(see page 18)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Guard locking
Actuators
CES-A-LSP-..
f Opt. for aluminum prole mounting
f PVC connection cable
(see page 20)
No
CES-A-LSP-SB
f Opt. for aluminum prole mounting
f M5 plug connector
(see page 20)
No
CES-A-LNN-
f Cube-shaped
f PVC connection cable
(see page 22)
No
CES-A-BBN
f Cube-shaped
(see page 31)
CES-A-LNN-SC
f Cube-shaped
f M8 plug connector
(see page 22)
No
CES-A-BDN
f Cylindrical design 6 mm
(see page 32)
CES-A-LNA-
f Cube-shaped
f PVC or PUR connection cable
(see page 24)
No
CES-A-BBA
f Cube-shaped
(see page 33)
CES-A-LCA-
f Cube-shaped
f Seal included
f PVC connection cable
(see page 24)
No
CES-A-BCA
f Cube-shaped
f Seal included
(see page 33)
CES-A-LNA-SC
f Cube-shaped
f M8 plug connector
(see page 24)
No
CES-A-BDA
f Round design 20 mm
(see page 35)
CES-A-LQA-SC
f Cube-shaped
f M8 plug connector
f For large center offset
(see page 26)
No
CES-A-BQA
f Cube-shaped
f For large center offset
(see page 34)
CES-A-LMN-SC
f Cylindrical design M12
f M8 plug connector
(see page 28)
No
CES-A-BMB
f Cylindrical design M12
(see page 36)
CKS-A-L1B-SC-113130
f Key adapter for installation in
control panels
f M8 plug connector
(see page 40)
No
CKS-A-BK1-RD-113461
f Key for key adapter CKS
(see page 40)
CES-A-BSP
f Optimized for aluminum prole
mounting
(see page 30)
CEM-A-LE05
f With and without remanence
f Adjustable adhesive force (optional)
(see pages 46 - 49)
CEM-A-BE05
f Locking force 500 N
(see page 52)
CEM-A-LH10
f With and without remanence
(see page 50)
CEM-A-BH10
f Locking force 1,000 N
(see page 53)
CET-AX-
f M12 plug connector
(see page 58)
CET-A-BWK-50X
f Locking force 6,500 N
(see page 58)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
11
Connection cable
Read heads
CES-A-LSP-
Actuators
CES-A-BSP
page 20
page 30
CES-A-BBN
Bolts
CES-A-LNN-
page 31
page 22
Connection cable hard wired to the read head
CES-A-LNA-
CES-A-L XXXXXX
page 24
CES-A-LCA-
CES-A-BDN
page 32
CES-A-BBA
CES-A-L XXXXXX
page 33
CES-A-BCA
page
226/227
page 26
CES-A-LNA-SC
page 33
CES-A-BDA
CES-A-L 077715
page 65
page 24
CES-A-LQA-SC
page 35
CES-A-BQA
page 26
CES-A-LMN-SC
page 34
CES-A-BMB
page 28
page 36
CES-A-BBN
CES-A-LNN-
page 31
page 65
page 22
CES-A-BDN
page 32
CKS-A-L1B-SC-113130
Pages 14 - 19
CKS-A-RD-113461
113461
CKS
FR
page 64
page 40
page 40
CES-A-LSP-
CES-A-BSP
page 20
page 30
CEM-A-LE05
CEM-A-BE05
Evaluation unit
page 65
page
228
page 65
Solenoid operating voltage
Pages 46 - 49
page 52
CEM-A-LH10
CEM-A-BH10
page 66
page 66
LED indicator
page 67
page 50
page 53
page 67
CET.-AX-
CET-A-BWK-50X
Connection cable CET-AX
page
235
page 65/66/68
page 58
page 58
12
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Important: Only typical values are listed in the table. The minimum and maximum values are listed in the technical data for the related
product.
15
Key to symbols
Combination possible, guard locking for personal protection
Combination not permissible
CES-A-LSP-
All items
CES-A-LNN-
All items
CES-A-LCA-
All items
CES-AZ-AES-01B
CES-A-LNA-
104770
All items
CES-AZ-AES-02B
CES-A-LQA-SC
104775
095650
CES-AZ-AES-04B
CES-A-LMN-SC
104780
CES-AZ-UES-01B
105139
CES-AZ-UES-02B
105140
CES-AZ-UES-04B
105141
096327
CET-A-BWK-50X
095175
CEM-A-BH10
094805
CEM-A-BE05
113461
CKS-A-BK1-RD
077791
CES-A-BMB
084720
CES-A-BDA
098108
CES-A-BQA
088786
CES-A-BCA
071840
CES-A-BBA
104730
CES-A-BDN-06-104730
106600
CES-A-BBN-106600
Read head
104970
Evaluation unit
CES-A-BSP-104970
Actuator
20
20
20
15
15
16
15
15
16
15
15
077790
CKS-A-L1B-SC
113130
23
5
-
CEM-A-LE05K-S2
094800
CEM-A-LE05R-S2
095792
CEM-A-LH10K-S3
095170
CEM-A-LH10R-S3
095793
CET.-AX-
All items
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
13
Cat.
4
PLe
Dimension drawing
114
22,5
Safety Unit
STATE OUT
DIA
99
5 6
S
Y
RESET
CES-AZ
Unicode
13
O1
Y1
23
14
DIA
Y2
24
Block diagram
Transponder
Readhead 1
0V UB J
CES-AZ-AES-01B
K2
K1
LED indicator
STATE Status LED
DIA
Diagnostics LED
OUT
Safety output status
TST
Additional connections
TST
Input for self-test
O1
Monitoring output (semiconductor)
DIA
Diagnostics output
Y1, Y2 Feedback loop
S
Start button connection
(monitoring of the falling edge)
EUCHNER
104770
O1
DIA
23 24
13 14
Y1
Y2
Ordering table
Series
Category and PL
acc. to EN ISO 13849-1
CES-AZ-AES-01B
Unicode
Up to 4 / PL e
104770
CES-AZ-AES-01B
CES-AZ-UES-01B
Multicode
Up to 4 / PL e
105139
CES-AZ-UES-01B
Connection sets
for evaluation unit
CES-AZ--01B
14
Version
Order no./item
104756
CES-EA-TC-AK04-104756
112631
CES-EA-TC-KK04-112631
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Parameter
min.
typ.
Housing material
max.
Unit
Plastic PA6.6
Dimensions
114 x 99 x 22.5
Mass
mm
0.2
kg
Ambient temperature at UB = DC 24 V
-20
+55
80
Degree of protection
IP20
Degree of contamination
Mounting
0.14
2.5
mm
21
24
27
V DC
150
mA
0.25
Safety contacts
AC/DC
21 60 V
300
- at switching voltage
AC/DC
5 30 V
10
4000
- at switching voltage
AC 5 230 V
2,000
10
mA
250
kV
100
according to EN 60947-5-2
10 x 106
210
ms
25
ms
10
mA
600
Ready delay 3)
10
12
Dwell time 4)
0.25
Hz
10
Monitoring outputs (diagnostics DIA, door monitoring contact O1, semiconductor output, p-switching, short circuitprotected)
- Output voltage
- Max. load
0.8 x UB
UB
V DC
20
mA
LOW
HIGH
15
UB
HIGH
10
V DC
mA
according to EN 60947-5-3
0.1 A
3A
e
1.9 x 10-8 6)
PFHd
Mission time
Number of switching cycles/year
1A
4 6)
Category
20
760,000
153,000
years
34,600
1) Without taking into account the load currents on the monitoring outputs.
2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of
the requirements in accordance with EN 60947-5-3, the switch-off delay can increase to max. 250 ms. After a brief actuation < 0.25 s, the switch-on delay can increase to max. 3 s if this is followed immediately by further actuation.
3) After the operating voltage is switched on, the relay outputs are switched off and the door monitoring contact is set LOW during the ready delay. For the visual indication of the delay, the green
STATE LED ashes at a frequency of approx. 15 Hz.
4) The dwell time is the time that the actuator must be outside the operating distance.
5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.
6) The value may be lower depending on the read head connected. See notes for the related read head.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
15
Cat.
4
PLe
Dimension drawing
114
45
13 TST DIA
S
J1
14
J2
0V
1 2
H1
H2
5 6
S
Y
99
Safety Unit
RESET
CES - AZ
Unicode
O1
O2
23
Y1
Y2
24
Block diagram
Transponder
Readhead 1
Readhead 2
EUCHNER
104775
K2
K1
LED indicator
STATE Status LED
DIA
Diagnostics LED
OUT
Safety output status
TST
Additional connections
TST
Input for self-test
O1, O2 Monitoring outputs (semiconductor)
DIA
Diagnostics output
Y1, Y2 Feedback loop
S
Start button connection
(monitoring of the falling edge)
Transponder
O1
O2
DIA
23 24
13 14
Y1
Y2
Ordering table
Series
Category and PL
acc. to EN ISO 13849-1
CES-AZ-AES-02B
Unicode
Up to 4 / PL e
104775
CES-AZ-AES-02B
CES-AZ-UES-02B
Multicode
Up to 4 / PL e
105140
CES-AZ-UES-02B
Connection sets
for evaluation unit
CES-AZ--02B
16
Version
Order no./item
104771
CES-EA-TC-AK06-104771
112630
CES-EA-TC-KK06-112630
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Parameter
min.
Housing material
Dimensions
Mass
Ambient temperature at UB = DC 24 V
Atmospheric humidity, not condensing
Degree of protection
Degree of contamination
Mounting
Number of read heads
Connection (plug-in screw terminals/coded)
Operating voltage UB (regulated, residual ripple < 5%)
the following applies
For the approval according to
Current consumption IB (with relay energized) 1)
External fuse (operating voltage UB)
Safety contacts
Switching current (relay outputs)
- at switching voltage AC/DC 21 60 V
- at switching voltage
- at switching voltage
AC/DC
AC
5 30 V
5 230 V
-20
-
0.14
21
Plastic PA6.6
114 x 99 x 45
0.25
IP20
2
Mounting rail 35 mm according to EN 60715
Max. 2 read heads per evaluation unit
24
max.
Unit
+55
80
mm
kg
C
%
2.5
27
mm
V DC
150
2 (relays with internally monitored contacts)
300
10
10
6,000
2,000
mA
A
mA
typ.
V
kV
A
290
210
ms
25
ms
250
5
3
-
200
8
10
10
300
10
600
12
0.25
0.8 x UB
-
UB
20
0
15
5
8
according to EN 60947-5-3
2
UB
10
0.1 A
1A
4 6)
e
1.9 x 10-8 6)
20
153,000
3A
760,000
ms
mA
s
s
Hz
%
V DC
mA
V DC
mA
years
34,600
1) Without taking into account the load currents on the monitoring outputs.
2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of
the requirements in accordance with EN 60947-5-3, the switch-off delay can increase to max. 430 ms. After a brief actuation < 0.4 s, the switch-on delay can increase to max. 3 s if this is followed
immediately by further actuation.
3) After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green
STATE LED ashes at a frequency of approx. 15 Hz.
4) The dwell time is the time that the actuator must be inside or outside the operating distance.
5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.
6) The value may be lower depending on the read head connected. See notes for the related read head.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
17
Cat.
4
PLe
Dimension drawing
45
13 TST DIA
S
J1
14
114
J2
0V
99
Safety Unit
H1
H2
H3
H4
S
Y
RESET
CES - AZ
Unicode
O1
O2
O3
O4
23
Y1
Y2
24
Block diagram
Transponder
Transponder
Transponder
Readhead 1
Readhead 2
Readhead 3
Readhead 4
EUCHNER
104780
K2
K1
LED indicator
STATE Status LED
DIA
Diagnostics LED
OUT
Safety output status
TST
Additional connections
TST
Input for self-test
O1O4 Monitoring outputs (semiconductor)
(p- or n-switching, see ordering table)
DIA
Diagnostic output (p- or n-switching,
see ordering table)
Y1, Y2 Feedback loop
S
Start button connection
(monitoring of the falling edge)
Transponder
O1
O2 O3 O4
DIA
23 24
13 14
Y1
Y2
Ordering table
Series
Category and PL
acc. to EN ISO 13849-1
Version
Order no./item
CES-AZ-AES-04B
Unicode
Up to 4 / PL e
104780
CES-AZ-AES-04B
CES-AZ-ALS-04B
Unicode
Up to 4 / PL e
113090 1)
CES-AZ-ALS-04B
CES-AZ-UES-04B
Multicode
Up to 4 / PL e
105141
CES-AZ-UES-04B
104776
CES-EA-TC-AK08-104776
112629
CES-EA-TC-KK08-112629
Connection sets
for evaluation unit
CES-AZ--04B
1) No UL or German Social Accident Insurance approval
18
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Parameter
min.
Housing material
Dimensions
Mass
Ambient temperature at UB = DC 24 V
Atmospheric humidity, not condensing
Degree of protection
Degree of contamination
Mounting
Number of read heads
Connection (plug-in screw terminals/coded)
Operating voltage UB (regulated, residual ripple < 5%)
For the approval according to
the following applies
Current consumption IB (with relay energized) 1)
External fuse (operating voltage UB)
Safety contacts
Switching current (relay outputs)
- at switching voltage AC/DC 21 60 V
- at switching voltage
- at switching voltage
AC/DC
AC
5 30 V
5 230 V
max.
Plastic PA6.6
114 x 99 x 45
0.25
-20
+55
80
IP20
2
Mounting rail 35 mm according to EN 60715
Max. 4 read heads per evaluation unit
0.14
2.5
21
24
27
Operation only with UL class 2 power supply, or equivalent measures
150
0.4
8
2 (relays with internally monitored contacts)
1
300
10
10
6,000
2,000
Unit
mm
kg
C
%
mm
V DC
mA
A
mA
typ.
V
kV
A
450
370
290
210
ms
25
ms
250
5
3
-
200
8
10
10
300
10
600
12
0.25
0.8 x UB
-
UB
20
0
15
5
8
according to EN 60947-5-3
2
UB
10
0.1 A
1A
4 6)
e
1.9 x 10-8 6)
20
153,000
3A
760,000
ms
mA
s
s
Hz
%
V DC
mA
V DC
mA
years
34,600
1) Without taking into account the load currents on the monitoring outputs.
2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of
the requirements in accordance with EN 60947-5-3, the switch-off delay can increase to max. 750 ms. After a brief actuation < 0.8 s, the switch-on delay can increase to max. 3 s if this is followed
immediately by further actuation.
3) After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green
STATE LED ashes at a frequency of approx. 15 Hz.
4) The dwell time is the time that the actuator must be inside or outside the operating distance.
5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.
6) The value may be lower depending on the read head connected. See notes for the related read head.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
19
3,3
Dimension drawing
8,3
5
R3
Mounting distance
CES-A-LSP-
M5
18,1
10
5,2 (2x)
10
97,1
57,5
Active face
LED
R4
Important:
Actuators must be ordered separately! See page 30.
20
For connection cable
see page 64
Terminal assignment
65
60
55
50
45
40
35
30
Screen
BN
WH
25
3
1 Read head
4 CES-A-LSP
20
15
10
5
H11 H12
SH1
5
10
15
CES-AZ
-5
20
-10
10
15
20
25
25
30
-15
-20
30
Z
-25
-30
-35
-40
-45
-50
-55
-60
-65
Ordering table
Series
Order no./item
104966
CES-A-LSP-05V-104966
10
104967
CES-A-LSP-10V-104967
SB
M5 plug connector
104969
CES-A-LSP-SB-104969
106633
Installation material 8-groove Bosch
106634
Installation material 10-groove Bosch
106635
Installation material 8-groove ITEM
V
PVC cable
CES-A-LSP-
Installation material
for CES-A-LSP-
20
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
Housing material
typ.
Reinforced thermoplastic, fully encapsulated
0.02
-25
Degree of protection
kg
+70
IP67
Installation position
Any
Method of operation
Inductive
Power supply
Connection
LED indicator
Cable length
Unit
max.
25
45
20
mm
10
- Switching hysteresis
1) These values apply to the installation of the read head and the actuator in an aluminum prole 45 x 45 mm.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
21
25
4,5
8
With connection cable
42
52,7
32 0,1
Active face
Active face
Active face
4,1
LED
Important:
Actuators must be ordered separately! See page 31.
Terminal assignment
5,3
5,4
4,1
12
19,4
Attention:
The operating distance may vary
depending on the substrate material
and installation situation.
4,6
2 safety screws
M4x14 included
Y
40
35
30
25
20
-30
-25
-1
5
5
5
10
SH1
15
H11 H12
5
-5
WH
10
4
1 Read head
3
0
-1
BN
15
-2
Screen
20
-10
15
20
CES-AZ
10
-5
-15
25
30
Z
-20
-25
-30
-35
-40
For a side approach direction for the actuator and read head, a
minimum distance of s = 6 mm must be maintained so that the
operating distance of the side lobes is not entered.
Approach directions
Ordering table
Series
V
PVC cable
Order no./item
106602
CES-A-LNN-05V-106602
10
113294
CES-A-LNN-10V-113294
25
115107
CES-A-LNN-25V-115107
106601
CES-A-LNN-SC-106601
CES-A-LNN-
SC
M8 plug connector
22
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
Housing material
typ.
Unit
max.
Dimensions
42 x 25 x 12
mm
0.025
Ambient temperature
-25
Degree of protection
IP67
Installation position
Any
Method of operation
kg
+70
Inductive
Power supply
Connection
LED indicator
Cable length
25
in x/z direction
50
in y direction
80
mm
Cable length l = 0 to 25 m
-
20
- Switch-on distance
10
- Switching hysteresis
in x/z direction
50
in y direction
80
19
14
mm
Cable length l = 0 to 25 m
- Switch-on distance
- Assured switch-on distance Sao
- Switching hysteresis
1) These values apply to the surface installation of the read head and the actuator.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
23
4,6
4,6
Dimension drawing
Active face
Active face
4,6
12
4,5
14
12
12
Active
face
5,5
f Cube-shaped design
42 x 25 mm
4,5
4,5
25
25
Active face
Active face
Important:
Actuators must be ordered separately! See page 33 and 35.
Terminal assignment
A0
CES-A-L 077715
42
0,2
min.38
6,8
32,6
32
48
42
"l"
Attention:
The operating distance may vary
depending on the substrate material
and installation situation.
32 0,2
32 0,2
CES-A-L XXXXXX
Seal
10
42
31
25
Active face
2 safety screws
M4x14 included
2 safety screws
M4x14 included
2 safety screws
M4x14 included
For connection
cable see page 65
Y
20
15
Screen
BN
WH
4
1 Read head
3
10
5
5
5
SH1
10
15
H11 H12
20
CES-AZ
10
15
20
For a side approach direction for the actuator and read head, a
minimum distance of s = 3 mm must be maintained so that the
operating distance of the side lobes is not entered.
Ordering table
Series
CES-A-LCA-
V
PVC cable
V
PVC cable
SC
M8 plug connector
Order no./item
1)
088785
CES-A-LCA-10V
071845
CES-A-LNA-05V
10
071846
CES-A-LNA-10V
15
071847
CES-A-LNA-15V
25
071975
CES-A-LNA-25V
077806
CES-A-LNA-05P
10
077807
CES-A-LNA-10P
15
084682
CES-A-LNA-15P
077715 2)
CES-A-LNA-SC
CES-A-LNA-
P
PUR cable
Version
24
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
Housing material
- CES-A-LNA-
typ.
Unit
max.
- CES-A-LCA-
Dimensions
42 x 25 x 12
mm
0.3
kg
-25
+50
- CES-A-LNA-
-25
+70
Degree of protection
- CES-A-LCA-
IP67
- CES-A-LNA-
IP67/IP69K
Installation position
Any
Method of operation
Inductive
Power supply
Connection cable
- CES-A-LCA-/CES-A-LNA-
- CES-A-LNA-
- CES-A-LNA-SC
Cable length
25
26
15
10
- Switching hysteresis
0.5
mm
- Switch-on distance
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
25
50 - 0,25
20,2
4,5
20
50 - 0,25
M 8x1
40 0,15
f Cube-shaped design
50 x 50 mm
f M8 plug connector (snapaction and screw terminals)
40 0,15
Active face
Important:
Actuators must be ordered separately! See page 34.
Terminal assignment
2 safety screws
M4x14 included
Y
30
30
Screen
BN
WH
4
1 Read head
3
20
20
-30
10
10
10
30
20
30
30
30
20
CES-AZ
20
20
10
SH1
10
10
H11 H12
-30
Ordering table
26
Series
Connection
Comment
Order no./item
CES-A-LQA-SC
SC
M8 plug connector
2 safety screws M4 x 14
included
095650
CES-A-LQA-SC
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
Housing material
typ.
Fortron, reinforced thermoplastic, fully encapsulated
Dimensions
50 x 50 x 20.2
Mass
Ambient temperature
mm
0.08
-25
kg
+70
25
47
15
Degree of protection
IP67
Installation position
Any
Method of operation
Inductive
Power supply
Cable length
Unit
max.
10
- Switching hysteresis
60
23
- Switch-on distance
16
- Switching hysteresis
28
mm
24
- Switching hysteresis
1.3
1) These values apply to the surface installation of the read head and the actuator.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
27
17
35
Attention:
The operating distance may vary
depending on the substrate material
and installation situation.
Terminal assignment
Active face
M 8x1
Important:
Actuators must be ordered separately! See page 36.
m
Center offset
19,7
M 12x1
32 1)
In inserted state
5 1)
8
30
37
For connection cable
see page 65
1) Metal-free zone
Y
8
6
Screen
BN
WH
4
1 Read head
3
2
2
4
SH1
H11 H12
CES-AZ
6
8
Ordering table
28
Series
Connection
Version
Order no./item
CES-A-LMN-SC
SC
M8 plug connector
Housing M12
077790
CES-A-LMN-SC
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
Housing material
typ.
Unit
max.
Dimensions
M12 x 1, length 38
mm
0.2
kg
Mass
Ambient temperature
C
- CES-A-LMN-SC
Ambient pressure
(only of active face in installed condition)
-20
+70
10
bar
Degree of protection
IP67
Installation position
Any
Method of operation
Inductive
Power supply
Cable length
15
10
3.5
- Switching hysteresis
0.1
0.3
Connection
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
29
Actuator CES-A-BSP
R2
Dimension drawing
18,1
10
5,2
97,1
57,5
Active face
Ordering table
Series
Comment
CES-A-BSP
Installation material
for CES-A-BSP
Version
Order no./item
104970
CES-A-BSP-104970
106633
Installation material 8-groove Bosch
106634
Installation material 10-groove Bosch
106635
Installation material 8-groove ITEM
Technical data
Value
Parameter
Unit
min.
Housing material
Degree of protection
Installation position
Power supply
30
max.
Mass
Ambient temperature
typ.
0.02
-25
kg
+70
IP67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BBN
Dimension drawing
25
4,5
32 0,1
Active face
Active face
42
12
2 safety screws
M4x14 included
Ordering table
Series
Comment
CES-A-BBN
2 safety screws M4 x 14
included
Version
Order no./item
106600
CES-A-BBN-106600
Technical data
Value
Parameter
Unit
min.
Housing material
typ.
Reinforced thermoplastic (PBT), fully encapsulated
Dimensions
Mass
Ambient temperature
-25
Power supply
42 x 45 x 12
mm
0.025
kg
Degree of protection
Installation position
max.
+70
IP67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
31
Actuator CES-A-BDN-06
Dimension drawing
Installation options
30 * min.
6,1
+0,1
0
+0,5
26 0
30 *
y
30 *
* Metal-free zone
Ordering table
Series
Comment
Version
Order no./item
104730
CES-A-BDN-06-104730
CES-A-BDN-06
Technical data
Value
Parameter
Unit
min.
Housing material
Mass
Degree of protection
Installation position
Power supply
32
max.
Dimensions
Ambient temperature
typ.
-40
26 x 6
mm
0.005
kg
+70
IP67/IP69K
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
48
42
12
Active
face
0,2
12
4,5
31
25
25
CES-A-B 071840
32
4,5
42
32 0,2
Active face
4,6
Seal
2 safety screws
M4x14 included
Active face
2 safety screws
M4x14 included
Ordering table
Series
CES-A-BBA
CES-A-BCA
Comment
2 safety screws M4 x 14
included
2 safety screws M4 x 14
included
Flat seal included
Version
Order no./item
071840
CES-A-BBA
088786
CES-A-BCA
Technical data
Value
Parameter
Unit
min.
Housing material
- CES-A-BBA
typ.
max.
- CES-A-BCA
Dimensions
Mass
42 x 25 x 12
mm
0.02
kg
Ambient temperature
- CES-A-BBA
-25
+70
- CES-A-BCA
-25
+50
Degree of protection
Installation position
Power supply
IP67/IP69K
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
33
Actuator CES-A-BQA
Dimension drawing
50 - 0,25
50 - 0,25
40 0,15
20,2
4,5
40 0,15
Active face
2 safety screws
M4x14 included
Ordering table
Series
Comment
CES-A-BQA
2 safety screws M4 x 14
included
Version
Order no./item
098108
CES-A-BQA
Technical data
Value
Parameter
Unit
min.
Housing material
Dimensions
Degree of protection
Installation position
Power supply
34
max.
Mass
Ambient temperature
typ.
-25
50 x 50 x 20.2
mm
0.07
kg
+70
IP67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BDA
Dimension drawing
Active
face
Active face
20
2,2
Ordering table
Series
Comment
Version
Order no./item
084720
CES-A-BDA-20
CES-A-BDA
Technical data
Value
Parameter
Unit
min.
typ.
max.
Housing material
Plastic PC
Dimensions
20 x 2.2
mm
0.0008
kg
Mass
Ambient temperature
-25
Degree of protection
Installation position
Power supply
+70
IP67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
35
0,80
Active face
Insertion tool
Insertion tool
With the aid of the insertion tool, the actuator
CES-A-BMB (cylindrical design) can be screwed
into a prepared M12 x 0.75 thread in the safety
door.
12,3
+0,12
-0,06
11,1
+0,12
-0,06
15
11
M12x0,75
Dimension drawing
t = 0,6
1,5
Ordering table
Series
Comment
Version
Order no./item
077791
CES-A-BMB
037662
CES-A-BMB
Insertion tool
Technical data
Value
Parameter
Unit
min.
Housing material
Mass
Ambient pressure
(only applies if the pressure acts on all sides of the actuator)
Degree of protection
Installation position
Power supply
36
max.
Stainless steel
Dimensions
Ambient temperature
typ.
mm
0.002
kg
-25
+70
10
bar
IP67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
37
38
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
The CKS system can thus be used when servicing installations, for example. Before the authorized personnel enters the installation, the CKS key
is withdrawn from the key adapter and brought along into the installation. If
the safety guard is now closed unintentionally, the installation cannot start.
This characteristic allows the CKS to be integrated into overall concepts
of installations with the highest safety level (Cat. 4. / PL e).
In addition to use as a lockout mechanism, the CKS system is ideally
suited as an electronic key transfer system or for assigning access rights
to stop a production process.
Your advantages
Versatile use, e.g. as a lockout mechanism, authorization for selecting
operating modes, key transfer system
f High degree of protection IP 67
f Simple connection via M8 plug connector
f
Important!
Use as a lockout mechanism is permissible only in
combination with unicode evaluation.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
39
Dimension drawing
Key adapter
40
70,5
M4
67
76
8
Plug connector M8
max. 4 mm
75
83
LED
10
32
84
Key CKS
Dimension drawing
113461
40
CKS
FR
25,4
31
Active face
(front and rear
sides)
Wiring diagram
WH
BN
H11 H12 SH1
3
1
Evaluation unit
CES-AZ-.ES
Ordering table
40
Series
Version
Order No./item
CKS-A-L1B-SC-113130
113130
CKS-A-L1B-SC-113130
CKS-A-BK1-RD-113461
113461
CKS-A-BK1-RD-113461
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
typ.
max.
Unit
Key adapter
Housing material
Mass
Ambient temperature
0.13
-20
kg
+70
IP67
(in installed state)
Installation position
On the front
33 x 68
mm
Operating distance 1)
Assured switch-off distance sar
30
Switching hysteresis
mm
Plug connector M8
(male socket, 3-pin)
-
LED indicator
25
Key
Housing material
Plastic (PC)
Mass
0.004
kg
IP67
-20
+70
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
41
42
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Your advantages
f Safety switch with transponder coding
f Every actuator is unique
f Maximum protection against tampering
f
Different versions
EUCHNER provides two CEM housing designs. The two versions differ in
their dimensions, according to the size of the solenoid. The safety switch
CEM with a locking force of 1,000 N is used with large, heavy safety doors.
This read head has an additional M8 plug connector for the connection of
an external LED display. When voltage is applied to the coil, it is indicated
to the user that the safety door is in the locking position. A display close
to the door handle is of advantage particularly for large, massive doors.
The smaller version of the read head CEM has a locking force of approx.
500 N. It is suitable for securing smaller safety doors and safety aps.
An LED indicator in the M8 male socket on the read head indicates to the
user when voltage is applied to the solenoid.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
43
Connection cable
evaluation unit
CES-A-KSB
(see page 65)
Connection cable
solenoid operating
voltage
(see page 66)
Connection cable
evaluation unit
CES-A-KSB
(see page 65)
Connection cable
LED indicator
(see page 67)
Connection cable
solenoid operating
voltage
(see page 66)
Connection cable
evaluation unit
CES-A-KWB
(see page 65)
44
Connection cable
solenoid operating
voltage
(see page 66)
Connection cable
evaluation unit
CES-A-KSB
(see page 65)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
45
Dimension drawing
50
40 0,10
5,4
16
49,5
65
80
14,5
Active
face
Solenoid
50
8
28
2 safety screws
M5x16 included
Actuator
Read head
Y
4
3
2
1
1
1
2
Wiring diagram
CEM-A-LE05K-S2
CEM-A-LE05R-S2
X1.4
Solenoid
UCM
YE
0V
X1.2
+UB
X1.1
UCM
Solenoid
NC
X1.4
X1.2
X1.1
YE
0V
X1.3
1 2
3 4
Solenoid operating
voltage
X1.1 f UCM/DC 24 V
X1.2 f +UB/DC 24 V
X1.3 f 0 V/GND
X1.4 f
X1
X3
Evaluation unit
CES
X3.1 f Data wire
X3.3 f Data wire
X3.4 f SH (screen)
X1.3
46
Series
Version
Order No./item
CEM-A-LE05K-S2
500
With remanence
094800
CEM-A-LE05K-S2
CEM-A-LE05R-S2
500
Without remanence
095792
CEM-A-LE05R-S2
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Parameter
min.
typ.
max.
Unit
General
Housing material
Aluminum
Plastic (PPS)
Solenoid material
Galvanized steel
Mass
Approx. 0.3
Ambient temperature
-25
IP67
Installation position
Any
kg
+50
Solenoid
Locking force in axial direction
500
Approx. 10 25%
Approx. 0.5
2.5
24 +10%/-15%
24 +10%/-15%
mm
V DC
Yes
Free-wheeling diode
Yes
100
at UCM = 0 V
at UCM = 24 V
12
100
mA
15
Power consumption
- CEM-A-LE05K-S2
Approx. 2.5
- CEM-A-LE05R-S2
Solenoid operating voltage connection
Approx. 2.8
M8 plug connector (male socket), 4-pin
Yellow LED integrated in the plug connector (see circuit diagram)
Read head
Operating distance for center offset m = 0
- Assured switch-off distance Sar
20
- Switch-on distance
- Switching hysteresis
0.7
Cable length l = 0 to 25 m
mm
25
1) The remanence disappears immediately when the door is opened and over time in de-energized solenoids.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
47
Dimension drawing
Programming adapter
50
40 0,10
5,4
4
16
3
M8x1
80
6,4
48,5
14,5
Active
face
49,5
65
50
28
2 safety screws
M5x16 included
Approach direction
Read head
8,3
Solenoid
Actuator
Wiring diagram
CEM-A-LE05H-S2
1 2
X1.4
3 4
+UB
Solenoid
UCM
Solenoid operating
voltage
X1.1 f UCM/DC 24 V
X1.2 f +UB/DC 24 V
X1.3 f 0 V/GND
X1.4 f
X1.2
X1.1
YE
0V
X1
X3
Evaluation unit
CES
X3.1 f Data wire
X3.3 f Data wire
X3.4 f SH (screen)
X1.3
48
Series
Version
Order No./item
CEM-A-LE05H-S2
500
104606
CEM-A-LE05H-S2
CEM-A-ZPS-110013
110013
CEM-A-ZPS-110013
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Parameter
min.
typ.
max.
Unit
General
Housing material
Aluminum
Plastic (PPS)
Solenoid material
Galvanized steel
Mass
Approx. 0.3
Ambient temperature
-25
IP67
Installation position
Any
kg
+50
Solenoid
Adhesive force
500
2.5
mm
24 +10%/-15%
24 +10%/-15%
V DC
Yes
Free-wheeling diode
Yes
Current consumption
- at connection X1.2 (UB)
at UCM = 0 V
at UCM = 24 V
25
100
10
Power consumption
Solenoid operating voltage connection
mA
Approx. 2.8
Read head
Operating distance for center offset m = 0
- Assured switch-off distance Sar
20
- Switch-on distance
- Switching hysteresis
0.7
Cable length l = 0 to 25 m
mm
Connection cable
25
1
2
4
X
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
49
Dimension drawing
6,5
X1: Solenoid
operating voltage
connection
52 0,15
29
32,5
Solenoid
60
78,5
95
Active
face
11
5,5
R5
55
38
65
Actuator
Read head
Y
4
3
2
1
1
1
2
Wiring diagram
CEM-A-LH10K-S3
LED 0 V
LED +
X2.1
External
LED display
External
LED display
LED +
External LED
indicator connection
CEM-A-LH10R-S3
X2.3
LED 0 V
X2.1 f
X2.2 f
X2.1
X2.3 f LED 0 V
X2.4 f
-
LED +
1
X2.3
X1.4
X1.4
3
4
0V
UCM
X1.1
0V
X1.3
X2
X1
X3
X1.2
Solenoid operating
voltage
X1.1
Solenoid
UCM
+UB
X1.2
Solenoid
NC
X1.3
X1.1
X1.2
X1.3
X1.4
f UCM/DC 24 V
f +UB/DC 24 V
f 0 V/GND
f
Evaluation unit
CES
X3.1 f Data wire
X3.3 f Data wire
X3.4 f SH (screen)
Ordering table
50
Series
Version
Order No./item
CEM-A-LH10K-S3
1,000
With remanence
095170
CEM-A-LH10K-S3
CEM-A-LH10R-S3
1,000
Without remanence
095793
CEM-A-LH10R-S3
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
typ.
Unit
max.
General
Housing material
Aluminum
Plastic (PPS)
Solenoid material
Galvanized steel
Mass
Approx. 0.9
Ambient temperature
-25
IP67
Installation position
Any
kg
+50
Solenoid
Locking force in axial direction
1,000
Approx. 40 25%
Approx. 0.7
2.5
24 +10%/-15%
24 +10%/-15%
mm
V DC
Yes
Free-wheeling diode
Yes
mA
at UCM = 0 V
at UCM = 24 V
12
225
mA
15
Power consumption
- CEM-A-LH10K-S3
Approx. 5.4
- CEM-A-LH10R-S3
Approx. 5.8
Read head
Operating distance for center offset m = 0
- Assured switch-off distance Sar
20
- Switch-on distance
- Switching hysteresis
0.7
Cable length l = 0 to 25 m
mm
25
500
mA
1) The remanence disappears immediately when the door is opened and over time in de-energized solenoids.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
51
Actuator CEM-A-BE05
Dimension drawing
50
24,5
40 0,10
8
5,4
14,5
49,5
65
80
Active
face
Solenoid
X
48
2 safety screws
M5x16 included
Ordering table
Series
Order No./item
CEM-A-BE05
094805
CEM-A-BE05
Technical data
Value
Parameter
Unit
min.
Housing material
Plastic (PPS)
Galvanized steel
Mass
52
max.
Aluminum
Ambient temperature
typ.
Approx. 0.18
-25
kg
+50
IP67
Active face opposite read head
4
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CEM-A-BH10
Dimension drawing
65
27,5
52 0,15
10
5,4
14,5
60
78,5
95
Active
face
Solenoid
X
4
63
2 safety screws
M5x16 included
Ordering table
Series
Order No./item
CEM-A-BH10
095175
CEM-A-BH10
Technical data
Value
Parameter
Unit
min.
typ.
Housing material
Aluminum
Plastic (PPS)
Galvanized steel
Mass
Ambient temperature
Approx. 0.3
-25
max.
kg
+50
IP67
Active face opposite read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
53
Dimension drawing
34
11,5
15
4
37
40
45
56
64
30
11,5
7,5
25
16
40
41,5
M5
64
84
26
11,5
6,
1
6,1
4
30
45
37
0[
56
64
Ordering table
Designation
Use
Order No./item
099425
EMP-L-CEM05
100110
EMP-B-CEM05
Sliding door
Sicherheitsschrauben M5
(im Lieferumfang von Lesekopf und Bettiger)
4 x M6
Standard Alu-Profil
Standard aluminium profile
Standard Alu-Profil
Standard aluminium profile
(30-45 mm)
Safety screws M5
(30-45 mm)
2 x M5
2 x M6
2 x M6
4 x M6
Sicherheitsschrauben M5
(im Lieferumfang von Lesekopf und Bettiger)
Safety screws M5
(included in delivery of readhead and actuator)
54
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
55
56
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Different versions
Along with the standard version with a single ramp, there is also the CET
with a double ramp that is perfectly suited to swing doors and rotary tables.
That is, wherever the approach is from two sides and where the read head
must also be "passed over".
As an option, EUCHNER also offers versions with escape release. This
feature enables people locked in to open the locked safety guard from
the inside in an emergency.
The range is supplemented by versions with different plug variants and
freely congurable LED control.
Your advantages
f
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
57
42
30
Version
CET.-AX-LRA-
Single ramp
LED 1
red
167
130
LED 2
green
16
Mechanical release
<15>
74,5 4
28
52
90
25
Actuator
CET-A-BWK-50X
Order separately
Active face
read head
34
25
Mechanical release
Is used for releasing the guard locking with the
aid of a tool. The mechanical release must be
sealed to prevent tampering (for example with
sealing lacquer).
67,2
5
Approach direction
Horizontal
Can be adjusted in 90 steps
15
11
Actuator CET-A-BWK-50X
for read head CET-AX
Lockout mechanism
The lockout mechanism can be used to prevent
maintenance personnel from being unintentionally
locked in the danger area, for example. In locked
position, the lockout mechanism prevents activation of guard locking. The lockout mechanism can
be secured in locking position with up to three
locks. The mechanical release can still be used.
58
4 safety screws
M5x16 included
Notes
f Special EUCHNER connection cables are required for the connection (see page 69/70/72).
Please take into account in the order!
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
Order no.
102161
103750
111918
M8
Order no.
102988
103444
109932
14
12
10
M 12 x 1
M8
<15>
8
16
20
24
Release by pressing
75
10,5
26,5
Dimension drawing
Order no.
111917
111918
Order no.
On request
30,5
140
42
83
85
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
59
Order no.
104062
UCM
CET1-AX-LRA-00-50X-SA
LED2
-S1
095735
CET1-AX-LRA-00-50L-SA
UCM
head
Read-
Actuator
104062
head
Read-
6
-S1
Actuator
Order no.
095735
100399
102161
103750
104051
106039
111917
111918
LED1
EUCHNER
LED1
EUCHNER
LED2
0V
0V
LED2
0V
-A1
-A1
0V UB J
0V UB J
CES-AZ-AES-01B
+
104770
104770
K2
EUCHNER
K1
TST
CES-AZ-AES-01B
O1
K2
EUCHNER
DIA
23 24
13 14
Y1 Y2 S
TST
K1
O1
DIA
23 24
13 14
Y1 Y2 S
Order no.
102988
103444
109932
X2.1
-S1
CET1-AX-LRA-00-50X-SC
X2.4
UCM
head
Read-
Actuator
102988
LED1
EUCHNER
LED2
0V
X2.2
-A1
0V UB J
CES-AZ-AES-01B
104770
K2
EUCHNER
TST
60
K1
O1
DIA
23 24
13 14
Y1 Y2 S
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Function
Wire color
connection cable*
CET1-AX-LRA-00-50X-SA
095735
WH
CET1-AX-LDA-00-50X-SE
100399
BN
(Screen)
YE
0V
GY
PK
0 V/GND solenoid
BU
Housing
RD
WH
BN
(Screen)
YE
GY
PK
BU
Housing
RD
Read head
CET1-AX-LRA-00-50F-SA
102161
CET1-AX-LDA-00-50F-SA
103750
CET1-AX-LRA-00-50X-SF
104051
CET1-AX-LRA-00-50X-SAC2333-1119177
111917
CET1-AX-LRA-00-50F-SAC2333-111918
111918
Plug connector
(view of connection side)
CET2-AX-LRA-00-50X-SA
106039 2)
With plug connector M12
and 2 freely congurable
LEDs
6
CET1-AX-LRA-00-50L-SA
104062
095735
CET1-AX-LRA-00-50X-SA
100399
CET1-AX-LDA-00-50X-SE
102161
CET1-AX-LRA-00-50F-SA
103750
CET1-AX-LDA-00-50F-SA
104051 1)
CET1-AX-LRA-00-50X-SF
111917
CET1-AX-LRA-00-50X-SA-C2333-111917
111918
CET1-AX-LRA-00-50F-SA-C2333-111918
106039 2)
CET2-AX-LRA-00-50X-SA
104062
CET1-AX-LRA-00-50L-SA
2 LEDs
(2 freely congurable)
2 LEDs
(1 freely congurable)
Lockout mechanism
Escape release
Double ramp
Single ramp
Open-circuit
current principle
Order no./item
Closed-circuit
current principle
Ordering table
75 mm
75 mm
75 mm
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
61
CET1-AX-LRA-00-50X-SC
102988
CET1-AX-LDA-00-50X-SC
103444
CET2-AX-LRA-00-50X-SC
109932 2)
Plug connector
(view of connection side)
Pin
Function
X 1.1
BN
X 1.3
WH
X1.1
X 1.4
BU
X2.2
X2.4
X 2.1
BN
X2.1
X2.3
X 2.2
0V
WH
X 2.3
0 V/GND solenoid
BU
X 2.4
BK
X1.4
X1.3
2 LEDs
(2 freely congurable)
2 LEDs
(1 freely congurable)
Lockout mechanism
On request
102988
CET1-AX-LRA-00-50X-SC
103444
CET1-AX-LDA-00-50X-SC
109932 1)
CET2-AX-LRA-00-50X-SC
Escape release
Double ramp
Single ramp
Open-circuit
current principle
Order no./item
Closed-circuit
current principle
Ordering table
Accessories
Ordering table
Designation
Actuator for CET
Safety screws M5 x 16
Handle for wire front release
62
Version/usage
Order no./item
096327
CET-A-BWK-50X
073456
M5x16/V100
099795
Handle for wire front release
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
General
Material, ramp
Material, read head housing
Installation position
Degree of protection according to IEC 60529
Mechanical life
Ambient temperature
Actuator approach speed, max.
max.
Stainless steel
Die-cast aluminum
Any (recommendation: actuating head downward)
IP67 (screwed tight with the related mating connector)
1 x 106 operating cycles
-20
+55
20
m/min
Unit
typ.
6,500
Fmax
FZh =
= 5,000
1.3
Approx. 1.0
X and Y: 5; Z: 4
N
kg
mm
1 Hz
(This value can vary depending on the evaluation unit used.
See system documentation of the related evaluation unit)
m
V
kV
24 +10%, -15%
12
100
V DC
W
%
Actuator
Parameter
Value
General
Housing material
Installation position
Degree of protection according to IEC 60529
Mechanical life
Ambient temperature
Locking force, max.
Mass
Stroke max.
Power supply
Unit
min.
typ.
max.
-20
Stainless steel
Active face opposite read head
IP67
1 x 106 operating cycles
6,500
Approx. 0.25
15
Inductive, via read head
+55
C
N
kg
mm
LED
Parameter
Value
min.
typ.
General
Connection voltage
Current consumption, max.
24 15%
6
Unit
max.
V
mA
Important:
The maximum safety category that can be achieved in accordance with EN ISO 13849-1 is dependent on the installation position of the safety switch
and the evaluation unit used. Pay attention to the table below during the selection of the evaluation unit.
Combination options
(extract only; you will nd further possible combinations in the system manual for the evaluation unit used)
Read head/
order number
Evaluation unit/
order number
Installation position
Head upward
3 / PL e
In this installation position the PFHd
value of the system (evaluation unit +
read head) decreases to 4.29 x 10-8
CET.-AX-
CES-AZ-.ES-
Head downward
or horizontal
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
4 / PL e
In this installation position the PFHd
value for the system (evaluation unit +
read head) is the same as that for the
evaluation unit
63
for CES-A-LSP-..SB
straight, M5 socket, 3-pin
6
4 (WH)
1 (BN)
3
(Schirm/Screen)
2 (NC)
27,5
7,5
Dimension drawing
View of
connection side
30
3,7
Ordering table
Use
Plug connector
Type of cable
For
read heads
CES-A-LSP-..SB
Straight
V
PVC cable
10
20
Order No./item
105555
C-M05F03-02X014PV05,0-ES-105555
105556
C-M05F03-02X014PV10,0-ES-105556
105559
C-M05F03-02X014PV20,0-ES-105559
Technical data
Parameter
Plug connector
Connection
Conductor cross-section
Material, outer sheath
Cable length
64
Value
min.
typ.
max.
Unit
mm
PVC 3.7 mm
mm
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
for CES-A-L/CEM-A-L/CET-AX/CKS
straight, M8 socket, 3-pin
for CES-A-L/CEM-A-L/CET-AX/CKS
angled, M8 socket, 3-pin
Dimension drawing 10
18,5
26,5
22,5
31
10
10
4 Schirm/Screen
4 Schirm/Screen
1 (BN)
3 (WH)
1 (BN)
3 (WH)
View of
connection side
"l"
"l"
View of
connection side
4,3...4,6
30
30
4,3...4,6
Ordering table
Use
Plug connector
Type of cable
Straight
V
PVC cable
10
20
25
For
Read heads
CES-A-L/
CEM-A-L/
CET-AX-L-SC/
CKS-SC
5
10
Straight
P
PUR cable
15
20
25
Angled
10
V
PVC cable
25
P
PUR cable
10
Order No./item
077935
C-M08F03-02X025PV03,0-ES-077935
077793
C-M08F03-02X025PV05,0-ES-077793
077767
C-M08F03-02X025PV10,0-ES-077767
077716
C-M08F03-02X025PV20,0-ES-077716
077717
C-M08F03-02X025PV25,0-ES-077717
084762
C-M08F03-02X025PU05,0-ES-084762
084763
C-M08F03-02X025PU10,0-ES-084763
084764
C-M08F03-02X025PU15,0-ES-084764
084765
C-M08F03-02X025PU20,0-ES-084765
084766
C-M08F03-02X025PU25,0-ES-084766
084701
C-M08F03-02X025PV10,0-ES-084701
099998
C-M08F03-02X025PV25,0-ES-099998
098590
C-M08F03-02X025PU10,0-ES-098590
Technical data
Parameter
Plug connector
Connection
Conductor cross-section
Material, outer sheath
Cable length
Value
min.
typ.
max.
Unit
mm
PVC 4.6 or PUR 4.3 (PUR cables are suitable for drag chains)
mm
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
65
Dimension drawing
18,5
10
4 (BK)
2 (WH)
2 (WH)
4 (BK)
26,5
22,5
31
10
10
3 (BU)
3 (BU)
1 (BN)
1 (BN)
View of
connection side
"l"
"l"
View of
connection side
30
4,3...5,2
30
4,3...5,2
Ordering table
Use
Plug connector
Type of cable
V
PVC cable
For
solenoid operating voltage
read heads
CEM-A-L/
CET-AX-L-SC
15
25
Straight
5
U
PUR cable
10
20
Angled
V
PVC cable
10
Order No./item
088813
C-M08F04-04X025PV05,0-ES-088813
088814
C-M08F04-04X025PV10,0-ES-088814
088815
C-M08F04-04X025PV15,0-ES-088815
095035
C-M08F04-04X025PV25,0-ES-095035
116049
C-M08F04-04X034PU05,0-ES-116049
116050
C-M08F04-04X034PU10,0-ES-116050
116051
C-M08F04-04X034PU20,0-ES-116051
084703
C-M08F04-04X025PV10,0-ES-084703
Technical data
Value
Parameter
Unit
min.
Plug connector
Screw terminal
Conductor cross-section
mm
66
max.
Connection
typ.
mm
CuZn nickel-plated
5 x cable
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
24,85
M8x1
31
26,5
37
M8x1
13,6
8,8
2 (WH)
4 (BK)
2 (WH)
3 (BU)
1 (BN)
3 (BU)
1 (BN)
View of
connection side
"l"
"l"
View of
connection side
4 (BK)
4,3...5,2
30
50
4,3...5,2
Ordering table
Use
Plug connector
Type of cable
For
LED indicator
read head CEM-A-LH10
Straight
V
PVC cable
10
15
Angled
V
PVC cable
10
Order No./item
088841
C-M08M04-04X025PV02,0-ES-088841
088842
C-M08M04-04X025PV05,0-ES-088842
088843
C-M08M04-04X025PV10,0-ES-088843
088844
C-M08M04-04X025PV15,0-ES-088844
084705
C-M08M04-04X025PV10,0-ES-084705
Technical data
Value
Parameter
Unit
min.
typ.
Plug connector
4-pin M8 plug
Connection
Screw terminal
Conductor cross-section
4 x 0.25
PUR black
PVC 5.0
max.
mm
mm
CuZn nickel-plated
Min. 10 x sheath diameter
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
mm
67
for CET
straight/angled, M12 socket, 8-pin
Dimension drawing
View of
connection side
RD 8
Important
Connection cables are not allowed to be extended.
5 GY
YE 4
6 PK
Screen 3
7 BU
Note
The connection cables with PUR sheath are suitable for drag chains with a minimum bending
radius of 60 mm (10 times the cable diameter).
BN 2
1 WH
14,5
"l"
10,5
M12 x 1
5,8...6
WH
BN
Screen
connected to pin 3
Ordering table
Use
Sheath
Plug connector
Straight
for CET
Connection cable
7 x 0.25 mm
with plug connector M12
and ying lead
20
25
PVC
10
099633
C-M12F08-07X025PV10,0-MA-099633
099634
C-M12F08-07X025PV20,0-MA-099634
103115
C-M12F08-07X025PV25,0-MA-103115
100456
C-M12F08-07X025PV10,0-MA-100456
Angled
20
10
PUR
105071
C-M12F08-07X025PV20,0-MA-105071
102218
C-M12F08-07X025PU10,0-MA-102218
Straight
25
68
Order no.
103782
C-M12F08-07X025PU25,0-MA-103782
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Unit
min.
Plug connector
typ.
8-pin M12 female connector
Connection
Screw terminal
Conductor cross-section
Material, connector housing
7 x 0.25
mm
TPU, self-extinguishing
CuZn nickel-plated
Bending radius
max.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
69
Coupling socket
Female connector
62
44
19,5
Dimension drawing
Pg9
Note
The connection cable for the read head can only
be extended using these self-assembly couplings/
plug connectors under the following conditions:
f The total maximum cable length is 25 m, taking
into account the switch-on distance.
f The cable specied by EUCHNER must be
used for the extension (screened, strand crosssection 2 x 0.25 mm).
f The plug connector housing must be electrically isolated from the machine ground.
Female connector
3-pin + PE
Pg9
Coupling socket
3-pin + PE
19
SW16
SW16
106
Inserted
1 = BN
3 = WH
f
f
f
H1
H2
SH (screen)
3
1
Ordering table
Designation
Version
Order No./item
KD4C1851
3-pin + PE
077434
KD4C1851
BS4C1851
3-pin + PE
077435
BS4C1851
Technical data
Value
Parameter
Unit
min.
typ.
Housing material
max.
IP65 (inserted)
Version
Order No./item
Connection set
for evaluation unit
CES-AZ--01B
104756
CES-EA-TC-AK04-104756
112631
CES-EA-TC-KK04-112631
104771
CES-EA-TC-AK06-104771
112630
CES-EA-TC-KK06-112630
104776
CES-EA-TC-AK08-104776
112629
CES-EA-TC-KK08-112629
Connection set
for evaluation unit
CES-AZ--02B
Connection set
for evaluation unit
CES-AZ-S-04B
70
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
82
65
42
37
20
45
For M6 screw
EN ISO 4762
20
39
58
205
138
6,5
For M5 screw
(12x)
For M6 screw
(12x)
9,5
22,5
27
Prole marking 45 x 45
Material thickness 10 mm
Material thickness 10 mm
Ordering table
Designation
Use
Order No./item
106695
EMP-L-CET
106694
EMP-B-CET
12,5
45
15
40
45 15
45
40
15
40
45
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
71
72
Fixing material/
screw size
Version/usage
Packaging unit
[qty.]
Order no.
2+2
106633
2+2
106634
2+2
106635
Safety screws
M4 x 14
(small head)
Read heads
CES-A-LN, CES-A-LC, CES-A-LQ
and
actuators
CES-A-BB, CES-A-BCA, CES-A-BQ
20
071863
Safety screws
M5 x 16
100
073456
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
30
16,7
35,5
Dimension drawing
Emergency unlocking
Using the emergency unlocking the read head can
be unlocked manually. In the locked position of the
emergency unlocking, a ball detent mechanism
prevents unintentional unlocking of the read head
due to vibration or similar.
In the unlocked position of the emergency unlocking, an integrated bolt engages in a bore on the
ange. To reset the emergency unlocking, rst the
bolt must be pressed inwards, out of the detent
mechanism, using a tool.
The emergency unlocking can be lead-sealed
(lead seal kit order no. 087256).
5,8
Emergency unlocking
for read head CET
71
30,4
25
20
Ordering table
Designation
Use
Version
Replacement key
Emergency unlocking
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Order No./item
098850
Mechanical key release
099434
Replacement key
103714
Emergency unlocking CET
087256
Lead seal kit for emergency unlocking
73
Cover
With the CET cover, tampering with the read head
CET is effectively prevented.
The cover prevents the use of simple tools to
manually press up the actuator.
Cover
for read head and actuator CET
Cover for door hinge on left mirror image
70
1
87
60
70
64
20
30
7,
5
2
6,5 (2x)
Double ramp
The ramp can be approached from two sides. It
can be passed over, e.g. for sliding doors.
Double ramp
for read head CET
Ordering table
Designation
Use
Version
Cover
74
Order No./item
098808
CET cover right
098807
CET cover left
114091
Double ramp for CET
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
18
62
64
CES
read head
0V
+ 24 V
0V
H11 H12
SH1
14 23
24
CES
13
B/C
PM-SCL
module
D
Input
Input
Input
Input
L+
I/O module
supply
SPS /
PLC
0V
Ordering table
Designation
Version
Order No./item
096945
PM-SCL-096945
Technical data
Parameter
Housing material
Degree of protection acc. to EN IEC 60529
Ambient temperature at UB = DC 24 V
Storage temperature
Degree of contamination (external, according to EN 60947)
min.
-20
-25
Mounting
Mass
Connection
Conductor cross-section
Switching voltage
Switching current (semiconductor output)
Internal fuse (ne-wire fuse 20 x 5 mm)
Inrush current limiting
Duration of limiting (at switch-on voltage 24 V)
Switching frequency
Load capacitance on which interference can be suppressed
(at input voltage 24 V)
Voltage drop after the limiting time has elapsed
Module current consumption
15
1
75
-
Value
typ.
max.
Polyamide UL 94.V2
IP20
+55
Atmospheric humidity 80%, not condensing
+70
2
Mounting rail 35 mm according to DIN EN 50022
Mounting rail 32 mm according to DIN EN 50035
Approx. 0.04
Connection terminals
0.14 2.5
40
3,000
6.3 A slow blow; breaking capacity min. 1 kA
60
160
1
Unit
C
C
kg
mm
V DC
mA
mA
ms
Hz
40
1.16
-
20
V
mA
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
75
76
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Functional description
Field evaluation units series CES-FD-AP make it possible to evaluate CES
read heads in the eld.
The safety outputs on the eld evaluation units are connected to the
machine control.
The system meets the following safety requirements:
f
This means that the safety system still functions even if an internal
component fails
If faults are detected, the safety circuit is switched off and the DIA LED
illuminates. In case of devices with a monitoring output OI, the output is
switched on.
The eld evaluation unit has a redundant switching design with selfmonitoring. This means that the safety system is still effective even if a
component fails.
The system is designed so that failures will not result in the loss of the
safety function. The occurrence of failures is detected by cyclic selfmonitoring at the latest on the next demand to switch on the safety
outputs (e.g. on starting).
If the safety door with the actuator should settle over time, the actuator
can drift out of the read head operating distance. The device recognizes
this situation and indicates that the actuator is in the limit range. This
allows the safety door to be readjusted in time.
Your advantages
f
CES-FD
f
f
f
f
DI
decentralized
periphery
e.g. ET 200pro
2
5
2
5
DO
3
n.c.
The read head is connected to the eld evaluation unit and reads the
actuator code.
Every EUCHNER actuator supplied has an electronic coding (unique coding) that is read by the read head. Only if a correct coding is detected
does the system accept the actuator. The code in an actuator cannot be
reprogrammed.
Unlike systems with unique code detection, on multicode systems a
specic code is not requested but instead it is only checked whether
the actuator is of a type that can be detected by the system (multicode
detection). There is no exact comparison of the actuator code with the
code dened in the safety switch (unique code detection).
The read head is fastened to the xed part of the safety guard.
The actuator attached to the movable part of the safety guard is moved
towards the read head by closing the door. The read head is connected
to the eld evaluation unit. When the switch-on distance is reached, power
is supplied to the actuator by the read head by induction and data can
be transferred.
If a permissible code is detected, the safety outputs are released.
Due to the combination of dynamic polling of the actuator and the redundant, diverse design of the safety electronics with the two feedback
safety outputs, the safety switch will enter the safe state with every
detectable fault.
When the safety guard is opened, the safety outputs switch off the safety
circuit and the monitoring output OD is switched off. The state of the safety
outputs is monitored internally by two microprocessors.
read head.
FO1B
0V
PLC
FO1A
UB
CES-FD-AP-...-.SI-...
Connection example:
Version for connection to decentralized peripheral equipment
Connection to safe control systems or safety relays
Do not use a control system or safety relay with pulsing for monitoring
short circuits or switch off the pulsing function in these devices. The
switch generates its own clock signals on the output lines FO1A/FO1B.
A downstream device must tolerate these test pulses, which may have a
length of up to 0.4 ms.
The inputs on the downstream device must be suitable for positiveswitching devices (pnp outputs), as the two outputs on the safety switch
deliver a level of +24 V in the switched-on state.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
77
78
CES-FD-AP-.-01-USI-
f No series connection
f Pulsing for short circuit detection
f Available in the unicode and multicode variants
(see page 82)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator
CES-A-LMN-SC
f Cylindrical design M12
f M8 plug connector
(see page 84)
CES-A-BMB
f Cylindrical design M12
(see page 86)
CKS-A-L1B-SC-113130
f Key adapter for installation
in control panels
f M8 plug connector
(see page 87)
CKS-A-BK1-RD-113461
f Key for key adapter CKS
(see page 87)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
79
Read heads
Actuator
CES-A-LMN-SC
CES-A-BMB
page 84
page 86
Bolt
CES-FD-AP-.01--USI-
page 82
page 82
CKS-A-L1B-SC-113130
CKS-A-RD-113461
113461
CKS
FR
page 87
80
page 87
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Important: Only typical values are listed in the table. The minimum and maximum values are listed in the technical data for the related
product.
15
Key to symbols
Combination possible, guard locking for personal protection
Combination not permissible
Read head
CES-A-BMB
CKS-A-BK1-RD
077791
113461
CES-A-LMN-SC
CES-FD-AP-.-01-USI-
077790
CKS-A-L1B-SC
113130
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
5
-
81
Cat.
4
PLe
Dimension drawing
Connection cable for read head
with M8 plug connector, 3-pin
Cable length:
1,000 mm
Cable length:
200 mm
12 - 0,2
6,5
95
4,5
11
19,5
30
6
75
5,5
85
LED indicator
STATE Status LED
DIA
Diagnostics LED
Coding lug
+0,5
0
Pin
Designation
Description
Wire color
H1
Data wire
BN
H2
Data wire
WH
SH
Screen
Pin
5-pin,
pin 5
5-pin
not
used
M8 plug
connector,
3-pin
3
1
Designation
Description
Wire color
UB
Power supply DC 24 V
BN
FO1A
WH
0V
Ground DC 0 V
BU
FO1B
BK
OD
Monitoring output
GY
1
3
5
4
+UB
0V
FO1A
FO1B
OD
X1.1
X1.3
X1.2
X1.4
X1.5
+UB
0V
FO1A
FO1B
n.c.
X1.1
X1.3
X1.2
X1.4
X1.5
Safety screws see page 89. Connection cables see page 156 ff.
Ordering table
Series
Category and PL
acc. to EN ISO 13849-1
Version
Order no./item
CES-FD-AP-U-01-
Unicode
4 / PL e
119865
CES-FD-AP-U-01-USI-119865
CES-FD-AP-M-01-
Multicode
4 / PL e
115534
CES-FD-AP-M-01-USI-115534
Connection cable
with M12 plug connector, 5-pin
Extension
for read head cable with M8 plug connector, 3-pin
82
5 m, PVC
100183
10 m, PVC
100184
20 m, PVC
100185
0.4 m, PUR
115464
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Parameter
min.
typ.
Housing material
max.
Unit
Plastic PBT
Dimensions
Mass
95 x 30 x 12
mm
0.04
kg
Ambient temperature at UB = DC 24 V
- With connection cable with M12 plug connector
- Connection cable laid rigidly
-20
+65
-0
+65
+70
Storage temperature
-20
Degree of protection
IP67
Safety class
III
Degree of contamination
Installation position
any
Connection
- Evaluation
- Read head
24 15% (PELV)
V DC
45
mA
DC 24 V, class 2
0.25
1.5
U(FO1A)
HIGH
U(FO1B)
LOW
U(FO1A)/U(FO1B)
UB-1.5
0
UB
V DC
150
mA
DC-13 24 V 150 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive
loads.
0.25
Off-state current Ir
Monitoring output OD 2)
mA
UB
V DC
- Max. load
50
mA
75
1.5
kV
Hz
- Output voltage
Resilience to vibration
Switching frequency
10
Repeat accuracy R
EMC protection requirements
according to EN 60947-5-3
4
e
4.5 x 10 -9 / h
20
years
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
83
17
35
Attention:
The operating distance may vary
depending on the substrate material
and installation situation.
Terminal assignment
Active face
M 8x1
Important:
Actuators must be ordered separately! See page 86.
m
Center offset
19,7
M 12x1
32 1)
in inserted state
5 1)
8
30
37
For connection cable
see page 82
1) Metal-free zone
Y
8
6
Screen
BN
WH
4
1 Read head
3
2
2
4
SH1
H11 H12
CES-AZ
6
8
Ordering table
84
Series
Connection
Version
Order no./item
CES-A-LMN-SC
SC
M8 plug connector
Housing M12
077790
CES-A-LMN-SC
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
Housing material
typ.
Unit
max.
Dimensions
M12 x 1, length 38
mm
0.2
kg
Mass
Ambient temperature
C
- CES-A-LMN-SC
Ambient pressure
(only of active face in installed condition)
-20
+70
10
bar
Degree of protection
IP67
Installation position
Any
Method of operation
Inductive
Power supply
Cable length
0.7
10
3.4
- Switching hysteresis
0.05
0.2
Connection
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
85
0,80
Active face
Insertion tool
Insertion tool
With the aid of the insertion tool, the actuator
CES-A-BMB (cylindrical design) can be screwed
into a prepared M12 x 0.75 thread in the safety
door.
12,3
+0,12
-0,06
11,1
+0,12
-0,06
15
11
M12x0,75
Dimension drawing
t = 0,6
1,5
Ordering table
Series
Comment
Version
Order no./item
077791
CES-A-BMB
037662
CES-A-BMB
Insertion tool
Technical data
Value
Parameter
Unit
min.
Housing material
Mass
Ambient pressure
(only applies if the pressure acts on all sides of the actuator)
Degree of protection
Installation position
Power supply
86
max.
Stainless steel
Dimensions
Ambient temperature
typ.
mm
0.002
kg
-25
+70
10
bar
IP67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
Key adapter
40
70,5
M4
76
67
Plug connector M8
max. 4 mm
75
83
LED
10
32
84
Key CKS
Dimension drawing
113461
40
CKS
FR
25,4
31
Active face
(front and rear
sides)
Wiring diagram
WH
BN
H11 H12 SH1
3
1
Evaluation unit
CES
Ordering table
Series
Version
Order no./item
CKS-A-L1B-SC-113130
113130
CKS-A-L1B-SC-113130
CKS-A-BK1-RD-113461
113461
CKS-A-BK1-RD-113461
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
87
Value
min.
typ.
max.
Unit
Key adapter
Housing material
Mass
Ambient temperature
0.13
-20
kg
+70
IP67
(in installed state)
Installation position
On the front
33 x 68
mm
Operating distance 1)
Assured switch-off distance sar
35
Switching hysteresis
mm
Plug connector M8
(male socket, 3-pin)
-
LED indicator
0.7
Key
Housing material
Plastic (PC)
Mass
0.004
kg
IP67
-20
+70
88
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Version/usage
Packaging unit
[qty.]
Order no.
Safety screws
M4 x 14
(large head)
100
086232
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
89
90
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Functional description
The Coded Electronic Safety switch CES consists of two components:
f
f
Coded actuator
Safety switch
The device described in this section is integrated with the read head in a
standard housing according to IEC/EN 60947-5-2.
Thanks to the high degree of protection IP67, this switch can be used
directly on the safety guard in a very harsh environment. Semiconductor
technology allows for a compact design of the evaluation unit and wearfree switching with a theoretically unlimited number of operating cycles.
The information from the coded actuator is read by the device and processed at the same point. The transfer of static signals (information on
whether door open or closed) to the higher level switchgear permits the
use of connecting cables up to 300 m long with the system.
Serial wiring, i.e. the cascading of several devices, is possible. This feature
makes it possible for you to implement decentralized wiring concepts with
the safety switch CES.
Specically, the major advantage of the system is that the positioning of
the evaluation electronics directly at the safety guard saves space in the
control cabinet.
The system operator can read the current state of the safety switch on
the two LED indicators (one with double function). If the actuator is in the
operating distance, the OUT LED illuminates yellow. Even a possible fault
in the device is indicated by a red LED. If servicing is required, the safety
switch connected with an M12 plug connector can be replaced in seconds.
The required approach direction can also be set quickly on the compact
housing. After two fastening screws have been undone, the active face
of the read head can be set in 5 different positions.
The bit pattern read is compared with the code saved in the device; if the
data matches, the safety outputs (semiconductor outputs) are enabled and
the monitoring output (semiconductor output) is also set HIGH.
Due to the combination of dynamic polling of the actuator and the redundant, diverse design of the safety electronics with the two feedback safety
outputs, the device will enter the safe state with every detectable fault.
When the safety guard is opened, the safety outputs switch off the safety
circuit and the monitoring output (OUT) is switched LOW. The state of the
safety outputs is monitored internally by two microprocessors.
On an internal fault in the device, the safety circuit is switched off and the
OUT/ERROR LED illuminates red.
The device has a redundant circuit design with self-monitoring. This means
that the safety system is still effective even if a component fails.
Your advantages
Relocation of the evaluation electronics from the control cabinet to
the system
f Space saving in the control cabinet
f Decentralized wiring concept possible
CES-A-.5
f
f
f
f
f
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
91
The compact safety switches in the system family CES-A combine read
head and evaluation unit in one housing. The switches have two safety
outputs and one monitoring output. All outputs are semiconductor outputs.
The safety outputs can switch pulsed signals, e.g. from a safe control
system or a safety relay. Up to three safety outputs can be connected
in series.
Coded
actuator
Transponder
Output circuit:
/$
/$
Power
supply
for load A
5Load A
Read head
/$%
Pin assignment:
Pin
Housing:
NG 5
118 x 40 x 40 mm
Function
9
8
%
/$
/%
287
/$
/$%
/%
Core color
WH/white
BN/brown
GN/green
YE/yellow
GY/gray
PK/pink
BU/blue
RD/red
Connection:
M 12x1
8-pin, screened
Safety PLC
with static /
dynamic signals
/% 5'
/$% %8
/% <(
Test pulse 0
2 Pulsed output
9
,
Safety input
9
Test pulse 1
/$ 3.
2 Pulsed output
,
Safety input
9
287*<
8%
%1
9 :+
( Input
'&9
9
9
/$ *1
Mounting
When mounting several safety switches, observe the stipulated minimum
distance to avoid mutual interference.
min. 80mm
92
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
93
C05
Cat.
3
PLe
CES-A-C5E-01
f Category 3 according to EN ISO 13849-1
f PL e according to EN ISO 13849-1
f Available in the unicode variant
(see page 98)
C05
Cat.
4
PLe
94
CES-A-C5H-01 / CES-A-W5H-01
f Category 4 according to EN ISO 13849-1
f PL e according to EN ISO 13849-1
f Available in the unicode and multicode variants
(see page 98)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-A-BBA
f Cube-shaped
(see page 101)
CES-A-BCA
f Cube-shaped
(see page 101)
CES-A-BPA
f Square
(see page 102)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
95
Safety switch
Actuator
Bolt
CES-A-BBA
CES-A-L XXXXXX
page 101
CES-A-C5
CES-A-W5
CES-A-BCA
page 101
page 103
page
229/230
page 98
CES-A-BPA
page 102
96
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Important: Only typical values are listed in the table. The minimum and maximum values are listed in the technical data for the related
product.
15
Key to symbols
Combination possible, guard locking for personal protection
Combination not permissible
Safety switch
CES-A-C5E-01
077750
CES-A-C5H-01
091458
CES-A-W5H-01
097525
CES-A-BBA
CES-A-BCA
CES-A-BPA
071840
088786
098775
20
20
30
20
20
30
20
20
30
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
97
7,3
M12x1
30
0,1
LED OUT/ERROR
LED STATE
16,5
30
40
Dimension drawing
40,5
Active face
13
40
5,3
60 0,1
Approach direction
Can be adjusted in 90 steps
45,5
118
( 131 )
Block diagram
A1
6
+LA
8
+LB
2
+UB
EUCHNER
Lesekopf
CES-A-C5E-01
077750
LA
3
LB
4
-LAB
7
0V
1
OUT
5
Terminal assignment
Additional connections
OUT
Monitoring output (semiconductor)
1
2
3
4
Attention:
The operating distance may vary depending on
the substrate material and installation situation.
f 0V
f + UB
f LA
f LB
5
6
7
8
f
f
f
f
OUT
+ LA
-LAB
+LB
3
1
Ordering table
Series
CES-A-C5
Unicode
CES-A-W5
Multicode
98
Category and PL
acc. to EN ISO 13849-1
Version
Order no./item
3 / PL e
077750
CES-A-C5E-01
4 / PL e
091458
CES-A-C5H-01
4 / PL e
097525
CES-A-W5H-01
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-A-C5
CES-A-W5
Y
30
25
CES-A-BBA
20
-30
CES-A-L XXXXXX
15
10
page 101
5
5
5
10
15
10
CES-A-BCA
15
20
20
25
25
30
page 101
-30
Actuator
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm
must be maintained so that the operating distance of the side lobes is not entered.
45
40
35
30
25
20
15
10
5
51
-45
CES-A-BPA
5
01
10
15
20
25
30
35
40 5
4
page 102
52
02
53
03
54
04
5
Z
-45
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
99
Parameter
min.
typ.
-20
Housing material
Dimensions
Mass
Ambient temperature at UB = DC 24 V
Degree of protection
Safety class
Degree of contamination
Installation position
Connection
Operating voltage UB (regulated, residual ripple < 5%)
For the approval according to UL the following applies
Current consumption
Switching load according to UL
External fuse (operating voltage UB)
Power supply for load U(+LA)/U(+LB)
Safety outputs (LA/LB, 2 semiconductor outputs, p-switching, short circuit proof, electrically decoupled)
- Output voltage U(LA/U(LB) 1)
HIGH
U(LA)
HIGH
U(LB)
LOW
U(LA)/U(LB)
Switching current per safety output
External fuse (U(+LA)/U(+LB), safety circuit
Utilization category according to EN 60947-5-2
Monitoring output (OUT, semiconductor output, p-switching,
short circuit-proof)
- Output voltage
- Max. load
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Rated conditional short-circuit current
Resilience to vibration
Switching delay from state change 3)
Difference time between the two safety outputs
Ready delay 4)
Dwell time 5)
Switching frequency
Repeat accuracy R acc. to EN IEC 60947-5-3
Mounting distance between 2 switches or 2 actuators
EMC protection requirements
In combination with actuator CES-A-BBA/CES-A-BCA
Operating distance for center offset m = 0
- Switch-on distance
- Assured switch-on distance sao 6)
- Switching hysteresis 5)
- Assured switch-off distance sar
In combination with actuator CES-A-BPA
Operating distance for center offset m = 0
- Switch-on distance
- Assured switch-on distance sao
- Switching hysteresis 6)
- Assured switch-off distance sar
LED indicators
1)
2)
3)
4)
5)
6)
7)
8)
+55
Unit
mm
kg
C
Any
M12 plug connector, 8-pin, screen can be applied
18
24
27
Operation only with UL class 2 power supply, or equivalent measures
80
max. DC 24 V, class 2
0.25
8
18
27
V DC
mA
A
V DC
U(+LA) - 1.5
U(+LB) - 1.5
0
1
U(+LA)
U(+LB)
1
400
0.8 x UB
-
100
according to EN 60947-5-2
10
according to EN 60947-5-3
UB
20
300 2)
1.5
V DC
mA
V
kV
A
180
120
3
1
ms
ms
s
s
Hz
%
mm
18
2
-
20
3
-
40
15
1
-
22 7)
2
-
0.5
80
STATE
OUT/ERROR
OUT/ERROR
max.
LED green:
ashing:
LED yellow:
LED red:
CES-A-C5E-
3
e
4.29 x 10 -8/h
20
58
Normal operation
Teach-in operation
Actuator detected
- EMC interference
- Internal electronics fault
- Invalid teach-in operation
CES-A-C5H-/CES-A-W5H-
4
e
3.7 x 10 -9/h 8)
20
V DC
mA
mm
mm
years
Values at a switching current of 50 mA without taking into account the cable length.
Tested by German Social Accident Insurance up to 75 V.
Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator.
After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set LOW during the ready delay.
The dwell time of an actuator inside and outside the operating distance must be at least 0.5 s to ensure reliable detection of internal faults in the evaluation unit (self-monitoring).
Values apply to surface installation of the actuator.
On surface mounting on aluminum; in a non-metallic environment the typical switching distance increases to 30 mm.
Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), the German Social Accident Insurance certies a PFHd of 2.47 x 10-8.
100
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
48
42
12
Active
face
0,2
12
4,5
31
25
25
CES-A-B 071840
32
4,5
42
32 0,2
Active face
4,6
Seal
2 safety screws
M4x14 included
Active face
2 safety screws
M4x14 included
Ordering table
Series
CES-A-BBA
CES-A-BCA
Comment
2 safety screws M4 x 14
included
2 safety screws M4 x 14
included
Flat seal included
Version
Order no./item
071840
CES-A-BBA
088786
CES-A-BCA
Technical data
Value
Parameter
Unit
min.
Housing material
- CES-A-BBA
typ.
max.
- CES-A-BCA
Dimensions
Mass
42 x 25 x 12
mm
0.02
kg
Ambient temperature
- CES-A-BBA
-25
+70
- CES-A-BCA
-25
+50
Degree of protection
Installation position
Power supply
IP67/IP69K
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
101
Actuator CES-A-BPA
Dimension drawing
10
0
- 0,25
5,2
40
0,1
Active
face
30
CES-A-BPA-098775
Active face
2 safety screws
M5x10 included
Ordering table
Series
Comment
Version
Order no./item
CES-A-BPA
2 safety screws M5 x 10
included
098775
CES-A-BPA
Technical data
Value
Parameter
Unit
min.
Housing material
Mass
Installation position
Power supply
102
max.
PPS
0.025
typ.
kg
IP67/IP69K
-25
+70
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
For CES-A-C5/CES-A-W5
M12 plug, 8-pin, silicone-free
Dimension drawing
14
7
2
"l"
1 = WH
2 = BN
3 = GN
4 = YE
5 = GY
6 = PK
7 = BU
8 = RD
f
f
f
f
f
f
f
f
0V
+UB
LA
LB
OUT
+ LA
-LAB
+LB
Ordering table
Use
Plug connector
Type of cable
C-M12F08-08X025PV05,0-MW-077751
077752
10
For CES-A-C5
Straight
C-M12F08-08X025PV10,0-MW-077752
077753
15
V
PVC cable
Order no./item
077751
C-M12F08-08X025PV15,0-MW-077753
077871
20
C-M12F08-08X025PV20,0-MW-077871
077872
25
C-M12F08-08X025PV25,0-MW-077872
077873
50
C-M12F08-08X025PV50,0-MW-077873
Technical data
Value
Parameter
Unit
min.
typ.
Plug connector
max.
Connection
Conductor cross-section
8 x 0.25 screened
mm
PVC
Cable length
Max. 300 (taking into account the voltage drop due to the cable resistance, see table)
Voltage drop
[mA]
[m]
Output [V]
Cable [V]
Total [V]
6
(safety control system with
pulsed signals)
1 -100
1.4
0.1
1.5
101 - 300
1.4
0.4
1.8
1 - 15
1.5
0.2
1.7
50
(safety relay)
400
(e.g. small contactor)
16 - 50
1.5
0.5
2.0
51 - 100
1.5
1.0
2.5
101 - 300
1.5
3.0
3.5
1 - 15
1.7
1.2
2.9
16 - 50
1.7
4.0
5.7
51 - 100
1.7
8.0
9.7
101 - 300
1.7
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
103
104
Fixing material/
screw size
Version/usage
Packaging unit
[qty.]
Order no.
Safety screws
M4 x 14
(small head)
Actuator
CES-A-BBA, CES-A-BCA
20
071863
Safety screws
M5 x 10
Actuator
CES-A-BPA
100
073455
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
105
106
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Functional description
The Coded Electronic Safety switch CES consists of two components:
f
f
Coded actuator
Safety switch
In the case of the devices described in this section the read head and the
evaluation electronics are integrated in one housing.
Thanks to the high degree of protection IP67, this switch can be used
directly on the safety guard in a very harsh environment. Semiconductor
technology allows for a compact design of the evaluation electronics and
wear-free switching with a theoretically unlimited number of operating
cycles.
Devices in the system family CES-AH- have special safety outputs that
are suitable for the direct switching of large loads. In appropriate applications it is therefore not necessary to connect power relays or contactors
in between.
The information on the coded actuator is read by the device and processed
at the same point. The transfer of static signals (information on whether
door open or closed) to the higher level switchgear permits the use of
connecting cables up to 50 m long with the system.
Serial wiring, i.e. the cascading of several devices, is possible. This feature
makes it possible for you to implement decentralized wiring concepts with
the safety switch CES.
Specically, the major advantage of the system is that the positioning of
the evaluation electronics directly at the safety guard saves space in the
control cabinet.
The system operator can read the current state of the safety switch on
the two LED indicators (one with double function). A possible fault in the
device is indicated by a red LED. If servicing is required, the safety switch
connected with an M23 plug connector can be replaced in seconds.
EUCHNER supplies a corresponding mating connector (see sub-section
Accessories in this section).
The safety switches have a relatively large operating distance of up to
27 mm depending on the actuator. Compared with mechanical safety
switches, the assembly of the unit is much easier and the need for precision
in the door guide is also reduced considerably. Therefore the assembly
and maintenance costs are much lower.
The bit pattern read is compared with the code saved in the device, if the
data match the safety outputs are enabled (semiconductor outputs). A
feedback loop can also be integrated here.
For the safety outputs to switch on, there must be a voltage of UB on the
START input. This voltage can be supplied either using a jumper (automatic
start) or using a start button.
Due to the combination of dynamic polling of the actuator and the redundant, diverse design of the safety electronics with the two feedback safety
outputs, the device will enter the safe state with every detectable fault.
The safety outputs shut down the safety circuit if the safety guard is
opened. The state of the safety outputs is monitored internally by two
microprocessors.
To check the safe switching function, the safety outputs LA and LB are
shut down for approx. 6 ms at regular intervals. The loads connected
must tolerate these pulses. Using these pulses a dangerous short circuit
from 24 V to the outputs LA and LB is also detected. In the event of a
fault, the safety outputs are switched off and the DIA LED illuminates red.
Two LED indicators (with varying sequence of ashes) on the device make
possible quick diagnostics.
The device has a redundant circuit design with self-monitoring. This means
that the safety system is still effective even if a component fails.
A dangerous short circuit between the outputs LA and LB is not detected
by the safety switch. In certain circumstances, however, it is possible
to exclude a failure as per EN 13849-1 section 7.3 (laying connection
cables with protection).
Your advantages
f Relocation of the evaluation electronics from the control cabinet to
the system
f Space saving in the control cabinet
f Decentralized wiring concept possible
f
CES-AH
The safety switch is fastened to the xed part of the safety guard.
The actuator attached to the movable part of the safety guard is moved
towards the read head tted in the safety switch by closing the door. When
the switch-on distance is reached, power is supplied to the actuator by
the inductive read head and data can be transferred.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
107
Mounting
min. 80mm
UB
START
UB
7
+LB +LA
5
4
Internal
logic
START
2
LA
3
Feedback
loop
LB
6
2)
0V
8
NC
1
1)
Feedback
loop
2)
1)
NC
9
GND
108
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
109
C03
Cat.
3
PLd
CES-AH-C03-
f Load current of 4 A can be switched directly
f Category 3 according to EN ISO 13849-1
f PL d according to EN ISO 13849-1
f Available in the unicode variant
(see page 114)
110
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-A-BBA
f Cube-shaped
(see page 117)
CES-A-BCA
f Cube-shaped
(see page 117)
CES-A-BPA
f Square
(see page 118)
CES-A-BRN
f Cube-shaped
(see page 119)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
111
Safety switch
Actuator
Bolt
CES-A-BBA
CES-A-L XXXXXX
page 117
CES-A-BCA
CES-AH-C03-
page 117
CES-A-BPA
page 120
page 114
page 118
CES-A-BRN
page 119
112
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Important: Only typical values are listed in the table. The minimum and maximum values are listed in the technical data for the related
product.
15
Key to symbols
Combination possible, guard locking for personal protection
Combination not permissible
CES-AH-C03-
20
20
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
22
CES-A-BRN-100251
100251
098775
CES-A-BPA
088786
CES-A-BCA
071840
Safety switch
CES-A-BBA
Actuator
27
113
40
0,3
15
27,5
40,3
0,5
Dimension drawing
34,5
Active face
LED status indication
40
M 23x1
40
30
5,3
Approach direction
Side, cannot be changed (see dimension drawing).
5,3
7,3
40
23,3
90
45,5
171
Plug connectors
see page 120
LB
UB
0V
NC
5 +LB
LA
4 +LA
LED indicator
STATE Status LED
DIA
Diagnostics LED
2 Start
Block diagram
NC
M23 plug-connector
(9-pin)
Attention:
The operating distance may vary depending on
the substrate material and installation situation.
CES-AH-C03-...
Terminal assignment
3
5
Pin
Designation
Description
NC
Not used *
START
Start input
LA
+ LA
+LB
LB
UB
Power supply, DC 24 V
0V
Ground, DC 0 V
NC
Not used *
* The unused connection pins are not allowed to be connected by the user.
Ordering table
114
Series
Category and PL
acc. to EN ISO 13849-1
Version
Order no./item
CES-AH-C03-AH-
Unicode
3 / PL d
106300
CES-AH-C03-AH-SM-106300
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-AH-C03-
Y
30
25
CES-A-BBA
20
-30
15
CES-A-L XXXXXX
10
page 117
5
5
5
10
10
15
15
20
25
20
CES-A-BCA
25
30
page 117
-30
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm
must be maintained so that the operating distance of the side lobes is not entered.
45
40
35
30
25
20
15
10
5
51
-45
CES-A-BPA
5
01
10
52
15
02
20
53
25
03
30
54
35
40 5
4
page 118
04
5
Z
Actuator
-45
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
Y
65
60
55
50
45
40
35
30
50
25
20
15
10
CES-A-BRN
5
5
5
10
15
20
25
30
35
X
page 119
-5
-10
-15
-20
-25
10
15
20
25
30
35
40
45
50
Z
-30
-35
-40
-45
-50
-55
-60
-65
For a side approach direction for the actuator and safety switch, a minimum distance of s = 12 mm
must be maintained so that the operating distance of the side lobes is not entered.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
115
Value
min.
typ.
-20
-20
-25
Plastic
40 x 40 x 171
0.35
IP67
III
3
max.
Unit
mm
kg
+55
+70
+70
Any
M23 plug connector, 9-pin
20
28
V DC
0.25
150
UB
10
mA
A
V DC
UB - 1.5
0
30
UB
4
4,000
DC-13 24V 4A
Caution: outputs must be protected with a free-wheeling diode in case of inductive
loads.
8
0
0.5
80
according to EN 60947-5-2
0.12
10
according to EN 60947-5-3
mA
UB
2
30
1.5
V DC
260
15
50
3
1
ms
s
ms
s
s
Hz
%
mm
V
kV
18
2
-
20
3
-
40
mm
18
1
-
22
2
-
58
mm
20
-
27
3
-
75
mm
3
d
1.01 x 10-7/h
20
years
Values at a switching current of 4 A without taking into account the cable length.
Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator.
The fault detection time is the time for the detection of an internal fault in the device. At least one of the switching elements on each safety output is opened during this process.
After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.
The dwell time of an actuator inside and outside the operating distance must be at least 0.5 s to ensure reliable detection of internal faults in the evaluation unit (self-monitoring).
116
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
48
42
12
Active
face
0,2
12
4,5
31
25
25
CES-A-B 071840
32
4,5
42
32 0,2
Active face
4,6
Seal
2 safety screws
M4x14 included
Active face
2 safety screws
M4x14 included
Ordering table
Series
CES-A-BBA
CES-A-BCA
Comment
2 safety screws M4 x 14
included
2 safety screws M4 x 14
included
Flat seal included
Version
Order no./item
071840
CES-A-BBA
088786
CES-A-BCA
Technical data
Value
Parameter
Unit
min.
Housing material
- CES-A-BBA
typ.
max.
- CES-A-BCA
Dimensions
Mass
42 x 25 x 12
mm
0.02
kg
Ambient temperature
- CES-A-BBA
-25
+70
- CES-A-BCA
-25
+50
Degree of protection
Installation position
Power supply
IP67/IP69K
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
117
Actuator CES-A-BPA
Dimension drawing
10
0
- 0,25
5,2
40
0,1
Active
face
30
CES-A-BPA-098775
Active face
2 safety screws
M5x10 included
Ordering table
Series
Comment
Version
Order no./item
CES-A-BPA
2 safety screws M5 x 10
included
098775
CES-A-BPA
Technical data
Value
Parameter
Unit
min.
Housing material
Mass
Installation position
Power supply
118
max.
PPS
0.025
typ.
kg
IP67/IP69K
-25
+70
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BRN
Dimension drawing
40
15
10,3
8,5
80
11
17
5,5
17
11
2 safety screws
M5x16 included
Active face
Active face
Ordering table
Series
Comment
Version
Order no.
CES-A-BRN
2 safety screws M5 x 16
included
100251
CES-A-BRN-100251
Technical data
Value
Parameter
Unit
min.
typ.
Housing material
PPS
Dimensions
Mass
Ambient temperature
-25
Power supply
80 x 40 x 15
mm
0.06
kg
max.
+70
IP67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
119
12
Dimension drawing
26
8 ...
SW20
50
Ordering table
Designation
Version
Order no./item
M23 plug
9-pin
P-M23F09-106597
106597
Technical data
Value
Parameter
Unit
min.
Housing material
Degree of protection acc. to EN 60529
120
typ.
max.
CuZn, nickel-plated
IP67 (inserted)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Version/usage
Packaging unit
[qty.]
Order no.
Safety screws
M4 x 14
(small head)
Actuator
CES-A-BBA, CES-A-BCA,
20
071863
Safety screws
M5 x 16
Actuator
CES-A-BRN
100
073456
Safety screws
M5 x 10
Actuator
CES-A-BPA
100
073455
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
121
122
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Your advantages
Your advantages
f
f
f
PLC
(5-pin)
n.c.
5
+UCM
4
For detailed information on connection, please refer to the system documentation at www.EUCHNER.de.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
123
CES-AP
CET-AP
n.c.
OA
2
UB
1
DO
2
5
2
5
0V
DI
decentralized
periphery
e.g. ET 200pro
n.c.
n.c.
Safety switch with guard locking and safe guard lock monitoring
Integrated CES-AP electronics
Direct connection to decentralized peripheral systems (e.g. ET200pro)
Safety category 4 and PL e according to EN ISO 13849-1 in case of
horizontal mounting, or head downward
Two safe semiconductor outputs and monitoring output OUT/OD
Safety outputs with pulsing
Input (optional) for the connection of feedback loop and start button
OB
0V
LED indicators
LED
STATE
DIA
Color
State
Signicance
illuminated
Normal operation
ashing
- Door open
- Teach-in operation or Power Up
- Actuator in limit range
(refer to the status table for further signal functions)
illuminated
green
red
124
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Flush mounting
Surface mounting
Actuator
Actuator
min. 80mm
Operating
distance
Operating
distance
min. 400 mm
Approach direction
C
D
min. 140 mm
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
125
C01
Cat.
4
PLe
CES-AP-C01-.H-
f One active face
f Approach direction adjustable
f Pulsing for short circuit detection
f Available in the unicode and multicode variants
(see page 130)
C02
Cat.
4
PLe
CES-AP-C.2-.H-
f Two active faces
f Door hinged on right or left
f Pulsing for short circuit detection
f Available in the unicode and multicode variants
(see page 136)
C04
Cat.
4
PLe
CES-I-AP-.-C04-
f Three active faces
f Pulsing for short circuit detection
f Available in the unicode and multicode variants
(see page 142)
Cat.
4
PLe
CET.-AP--AH-
f Guard locking with guard lock monitoring
f Pulsing for short circuit detection
f Available in the unicode and multicode variants
(see page 148)
126
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-A-BBN-C04-115271
f Cube-shaped, compact
(see page 146)
CET-A-BWK-50X
f Locking force 6,500 N
(see page 149)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
127
Safety switches
Actuator
Bolt
CES-A-BBA
CES-A-L XXXXXX
page 133
CES-A-BCA
page 133
CES-AP-C01
CES-A-BPA
page
229 - 233
page 155
page 130
page 134
CES-A-BRN
page 135
CES-AP-C.2
CES-A-BLN-.2
page 140
CES-A-BLN-U2
page 155
page 140
CES-A-BDN
page 141
page 136
CES-I-AP-.-C04
CES-A-BBN-C04-115271
page 146
page 155
page 142
CET.-AP-
CET-A-BWK-50X
Connection cable CET-AP
page
235
page 155
page 149
page 148
128
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Important: Only typical values are listed in the table. The minimum and maximum values are listed in the technical data for the related
product.
15
Key to symbols
Combination possible, guard locking for personal protection
Combination not permissible
CES-AP-CL2-
CES-I-AP-.-C04-
15
15
15
19
15
19
19
18
22
096327
CET-A-BWK-50X
115271
CES-A-BBN-C04-115271
100251
CES-A-BRN
098775
CES-A-BPA
088786
CES-A-BCA
071840
18
CES-AP-C01-
CES-AP-CR2-
CES-A-BBA
104730
CES-A-BDN-06-104730
103450
CES-A-BLN-U2-103450
104510
CES-A-BLN-L2-104510
100776
Safety switch
CES-A-BLN-R2-100776
Actuator
27
15
CET.-AP
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
129
Cat.
4
PLe
40
40,5
Dimension drawing
34
20,5
13
56,5
30
M12x1
LED indicator
5,5
47
Terminal assignment
Plug connector pin
8-pin
5-pin
5-pin,
pin 5 not
used
Designation
Description
n.c.
Not used
UB
Power supply, DC 24 V
OA
OB
DIA
Monitoring output
n.c.
Not used
0V
Ground, DC 0 V
RST
Plug connector
8-pin
5-pin
LED indicator
STATE Status LED
DIA
Diagnostics LED
3
1
Additional connections
DIA
Diagnostics output (semiconductor)
RST
Reset input
5
4
8-pin
RST
UB
0V
n.c.
n.c.
OA
OB
DIA
8
2
7
UB
0V
1
3
5-pin,
pin 5 not used
UB
0V
1
3
6
1
3
4
5
OA
OB
DIA
2
4
5
OA
OB
n.c.
2
4
5
Ordering table
Series
Category and PL
acc. to EN ISO 13849-1
Version
Order no.
CES-AP-C01-CH-SB
Multicode
4 / PL e
106798
CES-AP-C01-CH-SB-106798
CES-AP-C01-CH-SB
Multicode
4 / PL e
111708
CES-AP-C01-CH-SB-111708
CES-AP-C01-AH-SB
Unicode
4 / PL e
111145
CES-AP-C01-AH-SB-111145
CES-AP-C01-CH-SA
Multicode
4 / PL e
100250 1)
CES-AP-C01-CH-SA-100250
130
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-AP-C01-
Y
30
CES-A-BBA
25
CES-A-L XXXXXX
20
-30
15
page 133
10
5
5
10
CES-A-BCA
10
15
15
20
20
25
25
30
page 133
-30
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm
must be maintained so that the operating distance of the side lobes is not entered.
45
40
35
30
25
20
15
10
5
51
-45
CES-A-BPA
5
01
10
52
15
02
20
53
25
03
30
54
35
04
40
page 134
45
Actuator
-45
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
Y
65
60
55
50
45
40
35
30
50
25
20
15
10
CES-A-BRN
page 135
35
2
30 5
1
20 5
10
-5
-10
-15
-20
-25
10
15
20
25
30
35
40
45
50
Z
-30
-35
-40
-45
-50
-55
-60
-65
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
131
Parameter
min.
Housing material
typ.
max.
Unit
PBT V0 GF30
Dimensions
according to EN 60947-5-2
Mass
mm
0.4
kg
Ambient temperature at UB = DC 24 V
-20
+55
Storage temperature
-25
+70
Degree of protection
IP67
Safety class
III
Degree of contamination
Installation position
Any
Connection
24 15% (PELV)
Operation only with UL class 2 power supply, or equivalent measures
Current consumption
50
V DC
mA
DC 24 V, class 2
0.25
U(OA)
UB - 1.5
UB
HIGH
U(OB)
UB - 1.5
UB
LOW
U(OA)/U(OB)
400
V DC
mA
mA
300 3)
1.5
kV
Hz
Resilience to vibration
Switching frequency
according to EN 60947-5-2
-
10
Repeat accuracy R
0.8 x UB
UB
V DC
200
mA
18
15
- Switching hysteresis 2)
45
mm
22 5)
18
- Switching hysteresis 4)
58
27 6)
20
- Switching hysteresis 6)
75
- Switch-on distance
mm
mm
e
2.1 x 10 -9 / h
Mission time
1)
2)
3)
4)
5)
6)
20
years
Values at a switching current of 50 mA without taking into account the cable length.
Maximum current at an output in switched-off state.
Tested by employers liability insurance association up to 75 V
Values apply to surface installation of the actuator.
On surface mounting on aluminum; in a non-metallic environment the typical switching distance increases to 30 mm.
In case of surface mounting on steel.
132
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BBA
Actuator CES-A-BCA
Housing material PE-HD
Dimension drawing
48
42
12
Active
face
0,2
12
4,5
31
25
25
CES-A-B 071840
32
4,5
42
32 0,2
Active face
4,6
Seal
2 safety screws
M4x14 included
Active face
2 safety screws
M4x14 included
Ordering table
Series
CES-A-BBA
CES-A-BCA
Comment
2 safety screws M4 x 14
included
2 safety screws M4 x 14
included
Flat seal included
Version
Order no.
071840
CES-A-BBA
088786
CES-A-BCA
Technical data
Value
Parameter
Unit
min.
Housing material
- CES-A-BBA
typ.
max.
- CES-A-BCA
Dimensions
Mass
42 x 25 x 12
mm
0.02
kg
Ambient temperature
- CES-A-BBA
-25
+70
- CES-A-BCA
-25
+50
Degree of protection
Installation position
Power supply
IP67/IP69K
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
133
Actuator CES-A-BPA
Dimension drawing
10
0
- 0,25
5,2
40
0,1
Active
face
30
CES-A-BPA-098775
Active face
2 safety screws
M5x10 included
Ordering table
Series
Comment
Version
Order no.
CES-A-BPA
2 safety screws M5 x 10
included
098775
CES-A-BPA
Technical data
Value
Parameter
Unit
min.
Housing material
Mass
Installation position
Power supply
134
max.
PBT
0.025
typ.
kg
IP67 / IP69K
-25
+70
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BRN
Dimension drawing
40
15
10,3
8,5
80
11
17
5,5
17
11
2 safety screws
M5x16 included
Active face
Active face
Ordering table
Series
Comment
Order no.
CES-A-BRN
2 safety screws M5 x 16
included
100251
CES-A-BRN-100251
Technical data
Value
Parameter
Unit
min.
typ.
Housing material
PPS
Dimensions
Mass
Ambient temperature
-25
Power supply
80 x 40 x 15
mm
0.06
kg
max.
+70
IP 67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
135
Cat.
4
PLe
Dimension drawing
CES-AP-CR2-
Fastening lug with
reinforcement plate
Active face
23
12
4,25
30
11
19,5
4,4
LEDs
STATE
DIA
95
85 +0,5
With
connection cable
Connection cable
with M12 plug connector
LED indicator
STATE Status LED
DIA
Diagnostics LED
5,5
Active face
12
23
95
85 +0,5
With
connection cable
4,25
LEDs
11
Connection cable
with M12 plug connector
Length of cable piece:
200 mm
19,5
4,4
Active face
6,9
2 safety screws M4 x 14
and reinforcement plates included
CES-AP-CL2-
5,5
75,5
STATE
DIA
Active face
30
6,9
Approach direction
For approach directions see illustration "Approach
directions and minimum distance" on page 125.
75,5
Terminal assignment
Plug connector with latching connection, 6-pin, or ying lead
Additional connections
OUT
Monitoring output (semiconductor)
Pin
Connector assignment
+UB
X1.3
OA
NC
X1.4
OUT
Coding lug
X1.2
OB
X1.1
0V
Designation/description
Wire
color
UB
Power supply
DC 24 V
BN
OA
Safety output
channel 1
WH
0V
Ground
DC 0 V
BU
BK
X1.5
OB
Safety output
channel 2
X1.6
OUT
Monitoring output
GY
Not used
PK
5-pin,
pin 5 not used
+UB
0V
5
Coding lug
FO1A
FO1B
OD
X1.1
X1.3
X1.2
X1.4
X1.5
+UB
0V
FO1A
FO1B
n.c.
Pin
Designation/description
Wire
color
UB
Power supply
DC 24 V
BN
OA
WH
X1.3
Safety output
channel 1
X1.2
0V
Ground
DC 0 V
BU
OB
Safety output
channel 2
BK
OUT/
n.c.
Monitoring output
GY
X1.1
X1.4
1
2
3
X1.5
136
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-AP-C.2-
Mounting on plastic
Y
40
35
30
25
-30
20
-25
15
CES-A-BLN
-2
10
5
-1
-5
5
5
10
15
page 140
20
10
-5
-10
Actuator
-1
page 140
-15
15
20
25
30
Z
-20
-25
-30
-35
-40
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
CES-A-BDN-06
Operating distance as for actuator CES-A-BLN (see above)
page 141
Attention:
The operating distance may vary depending on the substrate material and installation situation.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
137
Parameter
min.
typ.
Housing material
max.
Unit
Plastic PBT
Dimensions
Mass
95 x 30 x 12
mm
0.04
kg
Ambient temperature at UB = DC 24 V
- Plug connector with latching connection
-30
+65
-40
+65
+65
-40
+70
IP69K
(IP67 for version with M12 plug connector)
Safety class
III
Degree of contamination
Installation position
Any
Connection
24 15% (PELV)
V DC
Current consumption
30
mA
DC 24 V, class 2
0.25
1.5
U(OA)
HIGH
U(OB)
LOW
U(OA)/U(OB)
UB-1.5
V DC
UB
150
mA
DC-13 24 V 150 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.
0.25
Off-state current Ir
Monitoring output OUT 2)
mA
UB
V DC
- Max. load
- Output voltage
50
mA
75
1.5
kV
Hz
Resilience to vibration
Switching frequency
10
Repeat accuracy R
EMC protection requirements
according to EN 60947-5-3
3)
15
10
in x/z direction
40
in y direction
60
mm
3)
19
14
in x/z direction
40
in y direction
60
mm
e
1.8 x 10 -9 / h
PFHd
Mission time
20
years
138
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Safety switches
CES-AP-C.2-AH-
Unicode
Safety switches
CES-AP-C.2-CH-
Multicode
Version
Order no./
item
105295 1)
CES-AP-CR2-AH-SF-105295
105294 1)
CES-AP-CL2-AH-SF-105294
106552
CES-AP-CR2-AH-SB-106552
106553
CES-AP-CL2-AH-SB-106553
111748
CES-AP-CR2-AH-SB-111748
111747
CES-AP-CL2-AH-SB-111747
105601
CES-AP-CR2-AH-L05-105601
105603
CES-AP-CL2-AH-L05-105603
106191
CES-AP-CR2-AH-L10-106191
106192
CES-AP-CL2-AH-L10-106192
106195
CES-AP-CR2-AH-L20-106195
106196
CES-AP-CL2-AH-L20-106196
100775 1)
CES-AP-CR2-CH-SF-100775
104509 1)
CES-AP-CL2-CH-SF-104509
106550
CES-AP-CR2-CH-SB-106550
106551
CES-AP-CL2-CH-SB-106551
109168
CES-AP-CR2-CH-SB-109168
109167
CES-AP-CL2-CH-SB-109167
105600
CES-AP-CR2-CH-L05-105600
105602
CES-AP-CL2-CH-L05-105602
106189
CES-AP-CR2-CH-L10-106189
106190
CES-AP-CL2-CH-L10-106190
106193
CES-AP-CR2-CH-L20-106193
106194
CES-AP-CL2-CH-L20-106194
1) UL approval
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
139
Actuator CES-A-BLN
Dimension drawing
CES-A-BLN-R2
CES-A-BLN-U2
75,5
Active face
4,4
30
11
30
11
19,5
19,5
4,25
Active face
4,4
35
4,25
85 +0,5
45
95
12
12
3,5
55
Active face
Active face
CES-A-BLN-L2
75,5
11
19,5
30
Active face
4,4
12
4,25
85 +0,5
95
Active face
Ordering table
Series
Actuator
CES-A-BLN
Version
Order no.
Item
95 mm x 30 mm x 12 mm
door hinge right
100776
CES-A-BLN-R2-100776
95 mm x 30 mm x 12 mm
door hinge left
104510
CES-A-BLN-L2-104510
55 mm x 30 mm x 12 mm
Usage independent of position of door hinge
103450
CES-A-BLN-U2-103450
Comment
2 safety switches
M4 X 14
and
reinforcement plates
included
Technical data
Parameter
Housing material
Dimensions
- CES-A-BLN-R2/CES-A-BLN-L2
- CES-A-BLN-U2
Mass
- CES-A-BLN-R2/CES-A-BLN-L2
- CES-A-BLN-U2
Ambient temperature
Degree of protection acc. to EN 60529
Installation position
Power supply
140
min.
-40
Value
typ.
Plastic PBT
max.
Unit
95 x 30 x 12
55 x 30 x 12
mm
0.04
0.02
IP67 / IP69K
Active face opposite read head
Inductive via read head
kg
+70
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BDN-06
Dimension drawing
Installation options
30 * min.
6,1
+0,1
0
+0,5
26 0
30 *
y
30 *
* Metal-free zone
Ordering table
Series
Comment
Version
Order no./item
104730
CES-A-BDN-06-104730
CES-A-BDN-06
Technical data
Value
Parameter
Unit
min.
Housing material
typ.
Macromelt PA-based plastic
26 x 6
Dimensions
Mass
Ambient temperature
Power supply
mm
0.005
-40
kg
Degree of protection
Installation position
max.
IP67 / IP69K
+70
1)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
141
Cat.
4
PLe
Dimension drawing
29,2
42
4,1
32
Active face
With
connection cable
LEDs
15,4
18
Approach direction
For approach directions see illustration "Approach
directions and minimum distance" on page 125.
10,6
M12x1
25
4,8
Connection cable
with M12 plug connector
Active face
LEDs
12,9
10,6
4,1
with M8
plug connector
Terminal assignment
M8 plug connector, 4-pin, or ying lead
Additional connections
OD
Monitoring output (semiconductor), not
present on all versions
Connector assignment
Pin
Designation/description
CES-I-AP--.SK-
+UB
X1.1
0V
X1.2
FO1B
UB
Power supply
DC 24 V
BN
FO1A
Safety output
channel 1
WH
0V
Ground
DC 0 V
BU
FO1B
Safety output
channel 2
BK
X1.3
FO1A
X1.4
Wire
color
+UB
0V
5
Coding lug
142
CES-I-AP--.SI-
5-pin,
pin 5 not used
FO1A
FO1B
OD
X1.1
X1.3
X1.2
X1.4
X1.5
+UB
0V
FO1A
FO1B
n.c.
X1.1
X1.3
Pin
Designation/description
UB
Power supply
DC 24 V
BN
FO1A
Safety output
channel 1
WH
0V
Ground
DC 0 V
BU
FO1B
Safety output
channel 2
BK
OD/
n.c.
Monitoring output
GY
1
2
3
X1.2
X1.4
X1.5
Wire
color
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-I-AP-.-C04-
Y
40
35
30
25
-30
20
-25
15
-2
10
0
-1
5
0
-5
5
5
10
15
page 146
20
10
-5
-10
Actuator
-1
CES-A-BBN-C04-115271
-15
15
20
25
30
Z
-20
-25
-30
-35
-40
For a side approach direction (y direction) for the actuator and safety switch, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
CES-A-BDN-06
Operating distance as for actuator CES-A-BBN-C04 (see above)
page 147
Attention:
The operating distance may vary depending on the substrate material and installation situation.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
143
Parameter
min.
typ.
Housing material
max.
Unit
Plastic PBT
Dimensions
Mass
42 x 25 x 18
mm
0.05
kg
Ambient temperature at UB = DC 24 V
- With connection cable with M12 plug connector
- Connection cable laid rigidly
-25
+65
-5
+65
+70
Storage temperature
-40
Degree of protection
IP67
Safety class
III
Degree of contamination
Installation position
non-ush
Connection
24 15% (PELV)
V DC
35
mA
DC 24 V, class 2
0.25
1.5
U(FO1A)
HIGH
U(FO1B)
LOW
U(FO1A)/U(FO1B)
UB-1.5
0
UB
V DC
150
mA
DC-13 24 V 150 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive
loads.
0.25
Off-state current Ir
Monitoring output OD 2)
mA
UB
V DC
- Max. load
- Output voltage
50
mA
300
1.5
kV
Hz
Resilience to vibration
Switching frequency
10
Repeat accuracy R
EMC protection requirements
according to EN 60947-5-3
15
10
in x/z direction
40
in y direction
60
mm
11
- Switching hysteresis 2)
- Assured switch-off distance sar
in x/z direction
40
in y direction
60
mm
e
4.1 x 10 -9 / h
PFHd
Mission time
20
years
144
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Order no./
item
Version
Plug connector M8, 4-pin
115324
CES-I-AP-U-C04-SK-115324
115150
CES-I-AP-U-C04-USI-115150
116502
CES-I-AP-U-C04-USB-116502
116503
CES-I-AP-U-C04-U05-116503
116504
CES-I-AP-U-C04-U10-116504
116505
CES-I-AP-U-C04-U20-116505
117325
CES-I-AP-M-C04-SK-117325
117323
CES-I-AP-M-C04-USI-117323
117324
CES-I-AP-M-C04-USB-117324
117328
CES-I-AP-M-C04-U05-117328
117329
CES-I-AP-M-C04-U10-117329
117330
CES-I-AP-M-C04-U20-117330
Safety switches
CES-I-AP-U-C04-
Unicode
Safety switches
CES-I-AP-M-C04-
Multicode
DI
2
5
0V
FO1B
n.c.
FO1A
2
UB
2
5
DO
3
decentralized
periphery
e.g. ET 200pro
CES-I-AP-...-USI-...
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
145
Actuator CES-A-BBN-C04-
Dimension drawing
32
Active face
42
4,8
18
25
Ordering table
Series
Comment
Actuator
CES-A-BBN
2 safety switches
M4 X 20
included
Order no.
Item
Version
115271
CES-A-BBN-C04-115271
Technical data
Parameter
Housing material
Dimensions
Mass
Ambient temperature
Degree of protection acc. to EN 60529
Installation position
Power supply
146
min.
-40
Value
typ.
Plastic PBT
42 x 25 x 18
0.03
IP67
Active face opposite read head
Inductive via read head
max.
+65
Unit
mm
kg
C
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BDN-06
Dimension drawing
Installation options
30 * min.
6,1
+0,1
0
+0,5
26 0
30 *
y
30 *
* Metal-free zone
Ordering table
Series
Comment
Version
Order no./item
104730
CES-A-BDN-06-104730
CES-A-BDN-06
Technical data
Value
Parameter
Unit
min.
Housing material
typ.
Macromelt PA-based plastic
26 x 6
Dimensions
Mass
Ambient temperature
Power supply
mm
0.005
-40
kg
Degree of protection
Installation position
max.
IP67 / IP69K
+70
1)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
147
Additional connections
OUT
Monitoring output (semiconductor)
OUT D Door monitoring output
RST
Reset input
Category according to EN ISO 13849-1
Due to two redundant design semiconductor
outputs (safety outputs) with internal monitoring
suitable for:
f Category 4 / PL e according to EN ISO 13849-1
Important: To achieve the stated category in
accordance with EN ISO 13849-1, both safety
outputs (OA and OB) must be evaluated.
The category is dependent on the installation
position of the safety switch:
Installation position
Achievable
category and
PL according to
EN ISO 13849-1
Head upward
3 / PL e
4 / PL e
Mechanical release
Is used for releasing the guard locking with the
aid of a tool. The mechanical release must be
sealed to prevent tampering (for example with
sealing lacquer).
Escape release (optional)
Is used for the manual release of the guard locking from within the danger area without tools.
Wire front release (optional)
The wire front release permits remote release of
the guard locking via a pull rope. Flexible routing
of the pull wire permits release of the guard locking in inaccessible installation situations.
The handle for the wire front release is not included. Please order separately (see page 135).
Lockout mechanism
The lockout mechanism can be used to prevent
maintenance personnel from being unintentionally
locked in the danger area, for example. In locked
position, the lockout mechanism prevents activation of guard locking. The lockout mechanism can
be secured in locking position with up to three
locks. The mechanical release can still be used.
Solenoid operating voltage
f DC
24 V
+10%, -15%
148
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Cat.
4
PLe
LED 1
STATE
DIA
167
130
LED 2
13,4
42
30
16
Mechanical
release
43,6
67,2
CET.-AP...CRA...
74,5 4 mm
28
<15>
15
11
90
CET.-AP...CDA...
25
34
6,5
For M6 screw
DIN 1207 / ISO 4762
X2 (pin)
X1 (pin)
25
Actuator
CET-A-BWK-50X
Order separately
52
Lift tappet
with read head
10,5
26,5
Actuator CET-A-BWK-50X
for safety switch CET-AP
Dimension drawing
42
30
23
21
16
75
24
20
Release
by pressing
21,5
4 safety screws
M5x16 included
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
149
Dimension drawing
30,5
140
42
83
85
150
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
2
5
n.c.
+UCM
n.c.
n.c.
OB
n.c.
0V
3
UB
OA
DO
2
5
0V
DI
decentralized
periphery
e.g. ET 200pro
(5-pin)
(5-pin)
Wiring diagram B
+24 V DC
-S1
UCM
CET
1
13
UB
RST
NC
NC
NC
NC
11
NC
15
NC
-B1
16
Actuator
Read head
rd
gn
Door
monitoring
output
Monitoring
output
10
Safety
output
Connected
load
Safety
output
Eval Unit
12
18
FE
19
0V(UCM)
0V
OUTD
4
OUT
5
OA
14
OB
17
NC
NC
GND
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
151
X1.1
X1.2
X1.4
X1.3
X2.5
X2.2
X2.1
X2.4
X2.3
Wire color
of connection cable
Pin
Designation
Function
X 1.1
X 1.2
X 1.3
X 1.4
X 1.5
UB
OA
0V
OB
-
Operating voltage, 24 V DC
Safety output, channel 1
Operating voltage, 0 V
Safety output, channel 2
n.c.
BN
WH
BU
BK
GY
X 2.1
X 2.2
X 2.3
X 2.4
0V UCM
UCM
n.c.
n.c.
0V solenoid
Operating voltage of guard locking solenoid, 24 V DC
BN
WH
BU
BK
X 2.5
n.c.
GY
1)
Wiring diagram
Lockout mechanism
Escape release
Feedback loop
Teach-in input
Double ramp
Single ramp
Multicode
Unicode
Open-circuit
current principle
Order no./item
Closed-circuit
current principle
CET3
111346
CET3-AP-CRA-AH-50X-SI-111346
114223
CET3-AP-CRA-AH-50X-SI-C2333-114223
114626
CET3-AP-CRA-AH-50F-SI-C2357-114626
105 mm
114073
CET3-AP-CRA-AH-50F-SI-114073
75 mm
114516
CET3-AP-CRA-AH-50F-SI-C2333-114516
75 mm
A
A
CET4
112082
CET4-AP-CRA-AH-50X-SI-112082
* L1 = hose length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see page 169).
152
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
RC18
With screen
bonding clamp
12
11
18
10
17
13
19
9
16
14
Designation
Function
UCM
VT
n.c.
RD
n.c.
GY
OA
RD/BU
OB
GN
UB
BU
RST
Reset input
GY/PK
GN/WH
OUT D
n.c.
YE/WH
10
OUT
Monitoring output
GY/WH
11
n.c.
BK
12
FE
Function earth
GN/YE
13
PK
BN/GY
15
4
7
6
Pin
14
n.c.
15
BN/YE
16
BN/GN
WH
17
n.c.
18
0V UCM
YE
19
0V UB
BN
Wiring diagram
Lockout mechanism
Escape release
Feedback loop
Teach-in input
Double ramp
Single ramp
Multicode
Unicode
Open-circuit
current principle
Order no./item
Closed-circuit
current principle
CET3
119106
CET3-AP-CRA-AH-50F-SH-C2312-119106
105 mm
* L1 = hose length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see page 169).
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
153
Value
min.
General
Material, ramp
Material, safety switch housing
Installation position
Degree of protection
Safety class
Degree of contamination
Mechanical life
Ambient temperature at UB
Actuator approach speed, max.
Locking force Fmax
Locking force FZh
in acc. with GS-ET-19
Mass
Degrees of freedom (actuator in recess) X, Y, Z
Connection type (depending on version)
Operating voltage UB (reverse-polarity protected, regulated,
residual ripple < 5%)
Current consumption IB
For the approval according to UL the following applies
Switching load according to UL
External fuse (operating voltage UB)
External fuse (solenoid operating voltage UCM)
Resilience to vibration
EMC protection requirements
Safety outputs OA/OB
- Output voltage UOA/UOB 1)
HIGH
UOA/UOB
LOW
UOA/UOB
Switching current per safety output
Utilization category according to EN 60947-5-2
Switching frequency
Repeat accuracy R acc. to EN IEC 60947-5-3
Monitoring outputs OUT and OUT D (optional)
Output voltage
Max. load
Teach-in input J or input feedback loop Y
HIGH
LOW
Solenoid
Solenoid operating voltage UCM (reverse polarity protected,
regulated, residual ripple < 5%)
Current consumption solenoid ICM
Power consumption
Duty cycle
Freely congurable LEDs 2)
Operating voltage
Reliability values according to EN ISO 13849-1
Category
Performance Level (PL)
PFHd
Mission time
-20
typ.
Stainless steel
Die-cast aluminum
Any (recommendation: switch head downward)
IP 67
(screwed tight with the related mating connector)
III
3
1 x 106 operating cycles
20
6,500
Unit
max.
+55
C
m/min
N
Approx. 1.0
X and Y: 5; Z: 4
2 plug connectors M12, 5-pin
or plug connector RC18
kg
mm
24 15%
V DC
80
Operation only with UL class 2 power supply, or equivalent measures
DC 24 V, class 2
0.5
3
0.5
2
according to EN 60947-5-2
acc. to EN IEC 60947-5-3
Semiconductor outputs (p-switching, short circuit-proof)
mA
UB - 1.5
0
1
UB
1
200
DC-13 24V 200mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
0.5
10
(p-switching, short circuit-proof)
0.8 x UB
UB
50
15
0
UCM
1
A
A
V DC
mA
Hz
%
V DC
mA
V
DC 24 V +10%/-15%
CET-1/3: 400, CET-2/4: 480
Max. 12
100
LED 1 red, LED 2 green
20.4
26.4
Head downward or horizontal
Head upward
4
3
e
e
3.1 x 10 -9 / h
4.29 x 10 -8 / h
20
20
mA
W
%
V DC
years
1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) Can vary depending on version. See data sheet.
Actuator
Parameter
Value
min.
Housing material
Installation position
Degree of protection according to IEC/EN 60529
Mechanical life
Ambient temperature
Locking force, max. (locked)
Mass
Stroke max.
Power supply
154
-20
typ.
Stainless steel
Active face opposite read head
IP67
1 x 106 operating cycles
6,500
Approx. 0.25
15
Inductive, via read head
Unit
max.
+55
C
N
kg
mm
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Flying lead
straight, M8 socket, 4-pin
Flying lead
angled, M8 socket, 4-pin
Dimension drawing
View of connection side
4 (BK)
2 (WH)
6
1 (BN)
3 (BU)
1 (BN)
3 (BU)
18,5
10
26,5
10
31
22,5
10
"l"
"l"
Cable end
sleeves
4,5
1 = BN
2 = WH
3 = BU
4 = BK
5 = GY
6 = PK
UB
OA
0V
OB
OUT
NC
1 = BN
2 = WH
3 = BU
4 = BK
f
f
f
f
UB
FO1A
0V
FO1B
1 = BN
2 = WH
3 = BU
4 = BK
30
30
f
f
f
f
f
f
4,3...5,2
4,3...5,2
f
f
f
f
UB
FO1A
0V
FO1B
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
155
1
2
Flying lead
M12 female connector 8-pin
3
3
Socket
6
5,9
4,1
5,9
4,1
4,1
Plug
4
3
1 = BN
2 = WH
3 = BU
4 = BK
5 = GY
f
UB
f
OA
f
0V
f
OB
f DIA/OUT
1 = BN
2 = WH
3 = BU
4 = BK
5 = GY
f
UB
f
OA
f
0V
f
OB
f DIA/OUT
1 = WH
2 = BN
3 = GN
4 = YE
5 = GY
6 = PK
7 = BU
8 = RD
f
f
f
f
f
f
f
f
IB
UB
OA
OB
DIA
IA
OV
RST
156
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Comment
Snap-on, 6-pin, length 5 m
click
6
pin
M8
4
pin
M12
5
pin
M12
8
pin
Order no./item
103556
C-R08F06-06X014PV05,0-ES-103556
103557
C-R08F06-06X014PV10,0-ES-103557
103558
C-R08F06-06X014PV15,0-ES-103558
103559
C-R08F06-06X014PV20,0-ES-103559
103560
C-R08F06-06X014PV25,0-ES-103560
088813
C-M08F04-04X025PV05,0-ES-088813
088814
C-M08F04-04X025PV10,0-ES-088814
088815
C-M08F04-04X025PV15,0-ES-088815
095035
C-M08F04-04X025PV25,0-ES-095035
084703
C-M08F04-04X025PV10,0-ES-084703
100183
C-M12F05-05X034PV05,0-MA-100183
100184
C-M12F05-05X034PV10,0-MA-100184
100185
C-M12F05-05X034PV20,0-MA-100185
100180
C-M12F05-05X034PV05,0-M12M05-100180
100181
C-M12F05-05X034PV10,0-M12M05-100181
100182
C-M12F05-05X034PV20,0-M12M05-100182
100177
C-M12F08-08X025PV05,0-MA-100177
100178
C-M12F08-08X025PV10,0-MA-100178
100179
C-M12F08-08X025PV20,0-MA-100179
M8
4
pin
M12
5
pin
M12
8
pin
Comment
M8 female connector 4-pin, length 5 m
Order no./item
116049
C-M08F04-04X034PU05,0-ES-116049
116050
C-M08F04-04X034PU10,0-ES-116050
116051
C-M08F04-04X034PU20,0-ES-116051
C-M12F05-05X025P10,0-MA-113190
C-M12F05-05X025P10,0-MA-113187
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
113190
113187
115566
C-M12F05-05X025P10,0-M12M05-115566
115565
C-M12F05-05X025P10,0-M12M05-115565
113189
C-M12F08-08X025PU10.0-MA-113189
113188
C-M12F08-08X025PU10.0-MA-113188
157
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
Value
typ.
6-pin female connector, straight
Snap-action
6 x 0.14
TPU, self-extinguishing
PVC 4.5
min. 5 x cable diameter
max.
Unit
mm
mm
mm
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Material, union nut
Static bending radius
Value
typ.
4-pin M8 female connector
Screw terminal
4 x 0.25
PUR black
PVC 4.3 5.2
CuZn nickel-plated
min. 5 x cable diameter
max.
Unit
mm
mm
mm
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Material, union nut
Static bending radius
Value
typ.
4-pin M8 female connector, straight
Screw terminal
4 x 0.34
TPU black
PUR 4.7
CuZn nickel-plated
min. 5 x cable diameter
max.
Unit
mm
mm
mm
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Bending radius
Value
typ.
5-pin M12 female connector, straight
Screw terminal
5 x 0.34
TPU, self-extinguishing
PVC 5.9
min. 5 x cable diameter
max.
Unit
mm
mm
mm
Technical data for M12 connection cable PUR, 5-core, with female connector, angled
Parameter
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
Value
typ.
5-pin M12 female connector, angled
Screw terminal
5 x 0.25
TPU, self-extinguishing
PUR 4.1
min. 5 x cable diameter
max.
Unit
mm
mm
mm
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
Value
typ.
8-pin M12 female connector, straight
Screw terminal
8 x 0.25
TPU, self-extinguishing
PVC 5.9
min. 5 x cable diameter
max.
Unit
mm
mm
mm
Technical data for M12 connection cable PUR, 8-core, with female connector, angled
Parameter
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
158
min.
Value
typ.
8-pin M12 female connector, angled
Screw terminal
8 x 0.25
TPU, self-extinguishing
PVC 5.2
min. 5 x cable diameter
max.
Unit
mm
mm
mm
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
78
Inserted
92
Inserted
With screen
bonding clamp
71
With
screen
bonding
clamp
85
12
1
17
19
14
12
11,6 0,3
17
10
19
14
16
15
11
18
13
15
View of
connection side,
socket
26
SW20
10
16
11,4 0,3
26
11
18
13
8
5
View of
connection side,
socket
Dimension drawing
M20x1,5
12
1
50,2
18
13
17
19
14
16
15
10
9
8
62
11
11,4 0,3
SW24
70
12
1
SW20
With
screen
bonding
clamp
50
26
View of
connection side,
socket
60
58
With screen
bonding clamp
18
13
11
17
19
14
16
15
10
9
8
View of
connection side,
socket
26
Conductor cross-section
[mm]
Pin
Core color
Conductor cross-section
[mm]
VT
0.5
RD
0.5
11
BK
0.5
12
GN/YE
GY
1.0
0.5
13
PK
0.5
RD/BU
0.5
14
BN/GY
0.5
GN
0.5
15
BN/YE
0.5
BU
1.0
16
BN/GN
0.5
GY/PK
0.5
17
WH
0.5
GN/WH
0.5
18
YE
0.5
YE/WH
0.5
19
BN
1.0
10
GY/WH
0.5
Pin
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
159
Order no./item
092761
RC18EF1,5M-C1825
092816
RC18EF3M-C1825
077014
RC18EF6M-C1825
077015
RC18EF8M-C1825
092898
RC18EF10M-C1825
077016
RC18EF15M-C1825
092726
RC18EF20M-C1825
092727
RC18EF25M-C1825
095993
RC18EF30M-C1825
092883
RC18EF1,5MF-C1825
092884
RC18EF3MF-C1825
092885
RC18EF6MF-C1825
092886
RC18EF8MF-C1825
092887
RC18EF10MF-C1825
092888
RC18EF15MF-C1825
092889
RC18EF20MF-C1825
092890
RC18EF25MF-C1825
109681
RC18EF30MF-C1825
1.5
3
6
Female connector RC18
with cable PUR
for CET-AP
18-pin + PE
8
10
15
20
25
30
1.5
3
6
8
10
15
20
25
30
Designation
8
10
15
20
25
1.5
3
6
8
10
15
20
25
160
Order no./item
Cable outlet left
092906
RC18WF1,5ML-C1825
092908
RC18WF3ML-C1825
077018
RC18WF6ML-C1825
077019
RC18WF8ML-C1825
092901
RC18WF10ML-C1825
077020
RC18WF15ML-C1825
092910
RC18WF20ML-C1825
092912
RC18WF25ML-C1825
092891
RC18WF1,5MLF-C1825
092893
RC18WF3MLF-C1825
092697
RC18WF6MLF-C1825
092895
RC18WF8MLF-C1825
092699
RC18WF10MLF-C1825
092701
RC18WF15MLF-C1825
092704
RC18WF20MLF-C1825
092724
RC18WF25MLF-C1825
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Value
min.
typ.
max.
Unit
Connection
Screw terminal
Conductor cross-section
16 x 0.5 / 3 x 1.0
mm
CuZn
Polyurethane
Bending radius
mm
Technical data for female connector RC18, straight/angled, with halogen-free cable
Parameter
Plug connector
Value
min.
typ.
Screw terminal
16 x 0.5 / 3 x 1.0
Polyurethane, halogen-free
Polyurethane, halogen-free
Unit
Connection
Conductor cross-section
max.
mm
CuZn
min. 10 x cable diameter
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
mm
161
59
Inserted
With screen
bonding clamp
52
12
26
M20x1,5
1
2
3
11
17
10
19
14
16
15
8
5
SW20
18
13
With screen
bonding clamp
52
52
26
12
18
13
11
17
10
19
14
16
15
58
60
26
1
2
8
5
SW20
SW24
M20x1,5
Ordering table
Series
Comment
Order no.
RC18 1)
18-pin + PE
EF
Female connector
WF
Female connector angled
Replacement pin crimp contacts
Conductor cross-section 19 x 0.75 - 1 mm2
074616
RC18EF
074617
RC18WF
094309
Pin crimp contact RCM
Technical data
Value
Parameter
Unit
min.
Grip material
Degree of protection acc. to EN 60529
162
typ.
max.
CuZn nickel-plated
IP65 (inserted)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Mounting plate
for safety switch CES-I-AP-.-C04
Dimension drawing
98
7,75
6,2
6,2
,2
R2
4,4
20
35
12,5
32 0,2
17,25
6
x
7,5
R2
,2
4
M
2,34
4,4
90
1
R1
,25
,25
R5
R2
,2
31
4,5
9,18
26,5
6,2
2,
2
90
22
38
6,2
17,25
7,75
12,5
12,5
17,25
7,75
64 0,2
6,2
,2
R2
H
H
4,4
R2
,2
M4
12,5
12
x
12,5
31
22
38
6,2
Spacer
for safety switch CES-I-AP-.-C04
42
32 0,2
R 0,1
5
R 2,4
25
R 2,4
16
,15
R0
6,5
0,5x45
Ordering table
Designation
Remark/use
Order no./item
AM-SET-PP
AM-SET-PPB
119690
AM-SET-PP-119690
119694
AM-SET-PPB-119694
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
163
Prole 30 x 30
Prole 40 x 40
Prole 45 x 45
Not customary
Not customary
2
Prole 40 x 40, sliding door
AM-SET-PPB-119694
AM-SET-PP-119690
AM-SET-PPB-119694
AM-SET-PPB-119694
AM-SET-PP-119690
AM-SET-PPB-119694
AM-SET-PPB-119694
AM-SET-PPB-119694
AM-SET-PPB-119694
AM-SET-PPB-119694
Not customary
Not customary
Not customary
AM-SET-PPB-119694
AM-SET-PPB-119694
AM-SET-PPB-119694
AM-SET-PP-119690
AM-SET-PP-119690
AM-SET-PP-119690
AM-SET-PPB-119694
AM-SET-PPB-119694
AM-SET-PPB-119694
AM-SET-PP-119690
AM-SET-PP-119690
AM-SET-PP-119690
11
Bosch EcoSafe
(mounted at front/rear)
164
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
82
65
42
37
20
45
For M6 screw
EN ISO 4762
20
39
58
205
138
6,5
For M5 screw
(12x)
For M6 screw
(12x)
9,5
22,5
27
Prole marking 45 x 45
Material thickness 10 mm
Material thickness 10 mm
Ordering table
Designation
Use
Order no./item
106695
EMP-L-CET
106694
EMP-B-CET
12,5
45
15
40
45 15
45
40
15
40
45
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
165
166
Fixing material/
screw size
Version/usage
Packaging unit
[qty.]
Order no.
Safety screws
M4 x 14
(small head)
Actuator
CES-A-BBA, CES-A-BCA
20
071863
Safety screws
M4 x 14
(large head)
100
086232
Safety screws
M5 x 16
Actuator
CES-A-BRN, CET-A-BWK
100
073456
Safety screws
M5 x 10
Actuator
CES-A-BPA
100
073455
Safety screws
M4 x 20
20
116978
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
30
16,7
35,5
Dimension drawing
Emergency unlocking
Using the emergency unlocking the safety switch
can be unlocked manually. In the locked position of the emergency unlocking, a ball detent
mechanism prevents unintentional unlocking of
the safety switch due to vibration or similar.
In the unlocked position of the emergency unlocking, an integrated bolt engages in a bore on the
ange. To reset the emergency unlocking, rst the
bolt must be pressed inwards, out of the detent
mechanism, using a tool.
The emergency unlocking can be lead-sealed
(lead seal kit order no. 087256).
5,8
Emergency unlocking
for safety switch CET
71
30,4
25
20
Ordering table
Designation
Use
Version
Order no./item
Replacement key
Emergency unlocking
098850
Mechanical key release
099434
Replacement key
103714
Emergency unlocking CET
087256
Lead seal kit for emergency unlocking
099795
Handle for wire front release
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
167
Cover
With the CET cover, tampering with the safety
switch CET is effectively prevented.
The cover prevents the use of simple tools to
manually press up the actuator.
Cover
for safety switch and actuator CET
Cover for door hinge on left mirror image
70
1
87
60
70
64
20
30
7,
5
2
6,5 (2x)
Double ramp
The ramp can be approached from two sides. It
can be passed over, e.g. for sliding doors.
Double ramp
for safety switch CET
Ordering table
Designation
Use
Cover
Version
Order no./item
098808
CET cover right
098807
CET cover left
114091
Double ramp for CET
168
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CET-A-BWK-50X
for safety switch CET-AP
4 safety screws
M5x16 included
Ordering table
Designation
Actuator for CET
Version/usage
Order no./item
096327
CET-A-BWK-50X
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
169
170
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Your advantages
Your advantages
f
f
f
f
f
f
f
f
f
f
f
f
f
Safety switch with guard locking and safe guard lock monitoring
Integrated CES-AR electronics
f A special evaluation unit is not required
f Possible to connect up to 20 devices (CES-AR, CET-AR, MGB-AR,)
in series in an AR chain
Safety category 4 and PL e according to EN ISO 13849-1 in case of
horizontal mounting, or head downward
Two safe semiconductor outputs and monitoring output OUT
Safety outputs with pulsing
Input (optional) for the connection of feedback loop and start button
Tip!
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-AR
CET-AR
You can also incorporate devices from the system family MGB--AR (Multifunctional Gate Box) in a CES-AR
switch chain. You will nd more detailed information in
the catalog Multifunctional Gate Box MGB and in the MGB
operating instructions at www.EUCHNER.de.
171
SPS
PLC
OUT output
The semiconductor output OUT is switched if the safety guard is closed
(actuator in the operating distance). It is not allowed to be used for safety
functions. The OUT outputs on the individual switches can, however, not
be polled if connected in series using a Y-distributor. Evaluation is only
possible on parallel wiring to the control cabinet.
CES-AR-C01 # 1
SPS
PLC
RST input
The switches in a chain in a fault state can be reset using the RST input. To
do this, a voltage of 24 V is applied to the RST input for at least 3 seconds.
It is not necessary to disconnect the supply of power to reset a fault.
STATE
DIA
CES-AR-C.2 # 1
SPS
PLC
CES-AR-C01 # n-1
STATE
DIA
STATE
DIA
CES-AR-C.2 # n
CES-AR-C.2 # 1
The switches are connected in series using plug connectors and Ydistributors. The rst switch in the chain must always be tted with a
bridging plug. If a safety door is opened or if a fault occurs on one of
the switches, the system shuts down the machine. A higher level control
system can, however, not detect which safety door is open or on which
switch a fault has occurred.
A special AR evaluation unit is required for this purpose (see page 169).
172
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Ready delay
After switching on, the unit carries out a self-test for 8 s. The system is
ready for operation only after this time.
Ready delay
After switching on, the unit carries out a self-test for 8 s. The system is
ready for operation only after this time.
Difference time
The safety outputs OA and OB switch with a slight time offset. They have
the same signal state at the latest after a difference time of 10 ms.
Difference time
The safety outputs OA and OB switch with a slight time offset. They have
the same signal state at the latest after a difference time of 10 ms.
LED
STATE
DIA
Color
State
Signicance
illuminated
Normal operation
ashing
green
red
illuminated
LED
STATE
DIA
Color
State
Signicance
illuminated
Normal operation
ashing
illuminated
green
red
LED 1
red
freely congurable*
LED 2
green
freely congurable*
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
173
Mounting CES-AR-C01
When mounting several safety switches, observe
the stipulated minimum distance to avoid mutual
interference.
Flush mounting
Surface mounting
Actuator
Actuator
min. 80mm
Operating
distance
Operating
distance
min. 120 mm
174
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
175
C01
Cat.
4
PLe
CES-AR-C01-.H-
f One active face
f Approach direction adjustable
f Pulsing for short circuit detection
f Available in the unicode, multicode and xcode variants
(see page 182)
1...20
C02
Cat.
4
PLe
CES-AR-C.2-.H-
f Door hinged on right or left
f Two active faces
f Pulsing for short circuit detection
f Available in the unicode and multicode variants
(see page 188)
1...20
Cat.
4
PLe
CET.-AR--.H-
f Guard locking with guard lock monitoring
f Pulsing for short circuit detection
f Available in the unicode and multicode variants
(see page 194)
Evaluation units
1...12
Cat.
4
PLe
176
CES-AR-AES-12
f Central evaluation of an AR switch chain
f For switch chains of up to 12 devices
(see page 221)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CET-A-BWK-50X
f Locking force 6,500 N
(see page 195)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
177
Connection cable
Safety switch
Actuator
Bolt
CES-A-BBA
CES-A-L XXXXXX
page 185
CES-A-BCA
page 185
CES-AR-C01-
CES-A-BPA
page
229 - 233
page 205
page 182
page 186
CES-A-BRN
Optional
AR evaluation unit
page 187
CES-AR-C.2
CES-A-BLN-.2
page 221
page 192
CES-A-BLN-U2
page 205
page 192
page 205
CES-A-BDN
page 188
page 193
CET-AR-
CET-A-BWK-50X
page 208
page
235
page 195
page 205
page 194
178
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Important: Only typical values are listed in the table. The minimum and maximum values are listed in the technical data for the related
product.
15
Key to symbols
Combination possible, guard locking for personal protection
Combination not permissible
CES-AR-C01
18
18
22
CET-A-BWK-50X
096327
104730
CES-A-BDN-06-104730
103450
CES-A-BLN-U2-103450
104510
CES-A-BLN-L2-104510
100776
100251
CES-A-BRN
098775
CES-A-BPA
088786
CES-A-BCA
071840
CES-A-BBA
Safety switch
CES-A-BLN-R2-100776
Actuator
27
15
CES-AR-CR2
15
CES-AR-CL2
15
19
15
19
CET.-AR
Safety switch
CES-AR-C01
from V1.1.2
(see rating plate on the device)
CES-AR-CR2
from V1.1.2
(see rating plate on the device)
AR evaluation unit
CES-AR-AES-12
098 225
CES-AR-CL2
from V1.1.2
(see rating plate on the device)
CET1/2-AR
from V1.1.2
(see rating plate on the device)
CET3/4-AR
from V1.0.0
(see rating plate on the device)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
179
SPS
PLC
SPS
PLC
CES-AR-C01 # 1
STATE
DIA
SPS
PLC
CES-AR-C.2 # 1
CET-AR # 1
Y-distributor M12
see page 212
CES-AR-C01 # n-1
STATE
DIA
CET-AR # n
180
CES-AR-C.2 # 1
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
181
40
40,5
Dimension drawing
34
20,5
13
56,5
LED indicator
30
M12x1
5,5
47
IA
0V
RST
OB
OUT
5
OA
IB
UB
Block diagram
Available coding options (see page 5)
f Unicode evaluation
f Multicode evaluation
f Fixcode evaluation
M12 plug-connector
(8-pin)
CES-AR-C01-...
Terminal assignment
Pin
LED indicator
STATE Status LED
DIA
Diagnostics LED
Additional connections
OUT
Monitoring output (semiconductor)
RST
Reset input
Designation
Description
IB
white
UB
Power supply, DC 24 V
brown
OA
green
OB
yellow
OUT
Monitoring output
gray
IA
pink
0V
Ground, DC 0 V
blue
RST
Reset input
red
RST
UB
0V
IA
3
1
IB
OA
OB
OUT
8
2
7
6
1
3
4
5
Ordering table
182
Series
Category and PL
acc. to EN ISO 13849-1
Order no.
CES-AR-C01-AH-SA
Unicode
4 / PL e
098941
CES-AR-C01-AH-SA
CES-AR-C01-CH-SA
Multicode
4 / PL e
098942
CES-AR-C01-CH-SA
CES-AR-C01-EH-SA
Fixcode
included)
(actuator CES-A-BPA
4 / PL e
098582
CES-AR-C01-EH-SA
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-AR-C01-
Y
30
CES-A-BBA
25
CES-A-L XXXXXX
20
-30
15
page 185
10
5
5
10
CES-A-BCA
10
15
15
20
20
25
25
30
page 185
-30
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm
must be maintained so that the operating distance of the side lobes is not entered.
45
40
35
30
25
20
15
10
5
51
-45
CES-A-BPA
5
01
10
52
15
02
20
53
25
03
30
54
35
04
40
page 186
45
Actuator
-45
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
Y
65
60
55
50
45
40
35
30
50
25
20
15
10
CES-A-BRN
page 187
35
2
30 5
1
20 5
10
-5
-10
-15
-20
-25
10
15
20
25
30
35
40
45
50
Z
-30
-35
-40
-45
-50
-55
-60
-65
For a side approach direction for the actuator and safety switch, a minimum distance of s = 12 mm
must be maintained so that the operating distance of the side lobes is not entered.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
183
Parameter
min.
Housing material
typ.
max.
Unit
PBT V0 GF30
Dimensions
according to EN 60947-5-2
Mass
mm
0.4
kg
Ambient temperature at UB = DC 24 V
-20
+55
Storage temperature
-25
+70
Degree of protection
IP67
Safety class
III
Degree of contamination
Installation position
Any
Connection
24 15% (PELV)
Operation only with UL class 2 power supply, or equivalent measures
Current consumption
50
mA
DC 24 V, class 2
V DC
0.25
U(OA)
UB - 1.5
UB
HIGH
U(OB)
UB - 1.5
UB
LOW
U(OA)/U(OB)
400
V DC
mA
Off-state current Ir
mA
300 2)
1.5
kV
Hz
Resilience to vibration
Switching frequency
according to EN 60947-5-2
-
10
Repeat accuracy R
0.8 x UB
UB
V DC
200
mA
18
- Switch-on distance
15
- Switching hysteresis 3)
45
22 3)
18
- Switching hysteresis 3)
58
mm
mm
27 4)
20
- Switching hysteresis 5)
75
- Switch-on distance
- Assured switch-on distance sao
mm
4
e
2.1 x 10 -9 / h 6)
20
years
Values at a switching current of 50 mA without taking into account the cable length.
Tested by German Social Accident Insurance up to 75 V.
Values apply to surface installation of the actuator.
On surface mounting on aluminum; in a non-metallic environment the typical switching distance increases to 30 mm.
In case of surface mounting on steel.
Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), the German Social Accident Insurance certies a PFHd of 2.47 x 10-8.
184
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BBA
Actuator CES-A-BCA
Housing material PE-HD
Dimension drawing
48
42
12
Active
face
0,2
12
4,5
31
25
25
CES-A-B 071840
32
4,5
42
32 0,2
Active face
4,6
Seal
2 safety screws
M4x14 included
Active face
2 safety screws
M4x14 included
Ordering table
Series
CES-A-BBA
CES-A-BCA
Comment
2 safety screws M4 x 14
included
2 safety screws M4 x 14
included
Flat seal included
Version
Order no.
071840
CES-A-BBA
088786
CES-A-BCA
Technical data
Value
Parameter
Unit
min.
Housing material
- CES-A-BBA
typ.
max.
- CES-A-BCA
Dimensions
Mass
42 x 25 x 12
mm
0.02
kg
Ambient temperature
- CES-A-BBA
-25
+70
- CES-A-BCA
-25
+50
Degree of protection
Installation position
Power supply
IP67/IP69K
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
185
Actuator CES-A-BPA
Dimension drawing
10
0
- 0,25
5,2
40
0,1
Active
face
30
CES-A-BPA-098775
Active face
2 safety screws
M5x10 included
Ordering table
Series
Comment
Version
Order no.
CES-A-BPA
2 safety screws M5 x 10
included
098775
CES-A-BPA
Technical data
Value
Parameter
Unit
min.
Housing material
Mass
Installation position
Power supply
186
max.
PBT
0.025
typ.
kg
IP67/IP69K
-25
+70
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BRN
Dimension drawing
40
15
10,3
8,5
80
11
17
5,5
17
11
2 safety screws
M5x16 included
Active face
Active face
Ordering table
Series
Comment
Version
Order no.
CES-A-BRN
2 safety screws M5 x 16
included
100251
CES-A-BRN-100251
Technical data
Value
Parameter
Unit
min.
typ.
Housing material
PPS
Dimensions
Mass
Ambient temperature
-25
Power supply
80 x 40 x 15
mm
0.06
kg
max.
+70
IP67
Active face opposite read head
Inductive via read head
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
187
Dimension drawing
Safety switch CES-AR-CR2-
Fastening lug with
reinforcement plate
Active face
23
12
4,25
30
11
19,5
4,4
LEDs
STATE
DIA
95
85 +0,5
With
connection cable
Connection cable
with M12 plug connector
LED indicator
STATE Status LED
DIA
Diagnostics LED
5,5
12
6
3
95
85 +0,5
11
Active face
With
connection cable
4,25
LEDs
Connection cable
with M12 plug connector
Length of cable piece:
1,000 mm or 2,000 mm
19,5
4,4
M8x1
23
5,5
STATE
DIA
Active face
75,5
30
M8x1
Approach direction
For approach directions see illustration "Approach
directions and minimum distance" on page 174.
75,5
Terminal assignment
Pin
Additional connections
OUT
Monitoring output (semiconductor)
RST
Reset input
Designation
Description
IB
white
UB
Power supply, DC 24 V
brown
OA
green
OB
yellow
OUT
Monitoring output
gray
IA
pink
0V
Ground, DC 0 V
blue
RST
Reset input
red
RST
UB
0V
IA
3
1
188
IB
OA
OB
OUT
8
2
7
6
1
3
4
5
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-AR-C.2-
Mounting on plastic
Y
40
35
30
25
-30
20
-25
15
CES-A-BLN
-2
10
5
-1
-5
5
5
10
15
page 192
20
10
-5
-10
Actuator
-1
page 192
-15
15
20
25
30
Z
-20
-25
-30
-35
-40
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm
must be maintained so that the operating distance of the side lobes is not entered.
CES-A-BDN-06
Operating distance as for actuator CES-A-BLN (see above)
page 193
Attention:
The operating distance may vary depending on the substrate material and installation situation.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
189
Parameter
min.
typ.
Housing material
PBT V0 GF30
Dimensions
95 x 30 x 12
Mass
max.
mm
0.04
kg
Ambient temperature at UB = DC 24 V
-30
+65
Storage temperature
-40
+70
Degree of protection
Unit
IP69K
(IP67 for version with M12 plug connector)
Safety class
III
Degree of contamination
Installation position
Any
Connection
24 15% (PELV)
V DC
Current consumption
50
mA
DC 24 V, class 2
0.25
1.5
U(OA)
HIGH
U(OB)
LOW
U(OA)/U(OB)
UB - 1.5
UB
200
DC-13 24 V 200 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
0.25
Off-state current Ir
V DC
mA
mA
UB
V DC
- Max. load
50
mA
75
1.5
kV
Hz
- Output voltage
Resilience to vibration
Switching frequency
10
Repeat accuracy R
In combination with actuator CES-A-BLN
2)
15
- Switch-on distance
10
- Switching hysteresis 2)
in x/z direction
40
in y direction
60
mm
2)
19
14
in x/z direction
40
in y direction
60
mm
4
e
1.9 x 10 -9 / h 3)
20
years
1) Values at a switching current of 50 mA without taking into account the cable length.
2) The operating distance may vary depending on the substrate material and installation situation.
3) Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), the German Social Accident Insurance certies a PFHd of 2.47 x 10-8.
190
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Safety switches
CES-AR-C.2-AH-
Unicode
Safety switches
CES-AR-C.2-CH-
Multicode
Version
Order no./
item
105751
CES-AR-CR2-AH-SG-105751
105753
CES-AR-CL2-AH-SG-105753
105746
CES-AR-CR2-AH-SA-105746
105748
CES-AR-CL2-AH-SA-105748
109046
CES-AR-CR2-AH-L05-109046
109047
CES-AR-CL2-AH-L05-109047
109050
CES-AR-CR2-AH-L10-109050
109051
CES-AR-CL2-AH-L10-109051
109054
CES-AR-CR2-AH-L20-109054
109055
CES-AR-CL2-AH-L20-109055
105750
CES-AR-CR2-CH-SG-105750
105752
CES-AR-CL2-CH-SG-105752
115792
CES-AR-CR2-CH-SA-115792
115793
CES-AR-CL2-CH-SA-115793
105745
CES-AR-CR2-CH-SA-105745
105747
CES-AR-CL2-CH-SA-105747
112928
CES-AR-CR2-CH-SA-112928
112929
CES-AR-CL2-CH-SA-112929
109044
CES-AR-CR2-CH-L05-109044
109045
CES-AR-CL2-CH-L05-109045
109048
CES-AR-CR2-CH-L10-109048
109049
CES-AR-CL2-CH-L10-109049
109052
CES-AR-CR2-CH-L20-109052
109053
CES-AR-CL2-CH-L20-109053
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
191
Actuator CES-A-BLN
Dimension drawing
CES-A-BLN-R2
CES-A-BLN-U2
75,5
Active face
4,4
30
11
30
11
19,5
19,5
4,25
Active face
4,4
35
4,25
85 +0,5
45
95
12
12
3,5
55
Active face
Active face
CES-A-BLN-L2
75,5
11
19,5
30
Active face
4,4
12
4,25
85 +0,5
95
Active face
2 safety switches M4 x 14
included
Ordering table
Series
Actuator
CES-A-BLN
Version
Order no.
Item
95 mm x 30 mm x 12 mm
Door hinge right
100776
CES-A-BLN-R2-100776
95 mm x 30 mm x 12 mm
Door hinge left
104510
CES-A-BLN-L2-104510
55 mm x 30 mm x 12 mm
Usage independent of position of door hinge
103450
CES-A-BLN-U2-103450
Comment
2 safety switches
M4 X 14
and
reinforcement plates
included
Technical data
Parameter
Housing material
Dimensions
- CES-A-BLN-R2/CES-A-BLN-L2
- CES-A-BLN-U2
Mass
- CES-A-BLN-R2/CES-A-BLN-L2
- CES-A-BLN-U2
Ambient temperature
Degree of protection acc. to EN 60529
Installation position
Power supply
192
min.
-40
Value
typ.
Plastic PBT
max.
Unit
95 x 30 x 12
55 x 30 x 12
mm
0.04
0.02
IP67 / IP69K
Active face opposite read head
Inductive via read head
kg
+70
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Actuator CES-A-BDN-06
Dimension drawing
Installation options
30 * min.
6,1
+0,1
0
+0,5
26 0
30 *
30 *
* Metal-free zone
Ordering table
Series
Comment
Version
Order no./item
104730
CES-A-BDN-06-104730
CES-A-BDN-06
Technical data
Value
Parameter
Unit
min.
Housing material
typ.
Macromelt PA-based plastic
Dimensions
Mass
Ambient temperature
-40
Power supply
26 x 6
mm
0.005
kg
+70
IP67 / IP69K 1)
Degree of protection
Installation position
max.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
193
Feedback loop
Versions with feedback loop permit monitoring of
connected devices (e.g. contactors). Additionally,
a start button can be integrated (see wiring diagrams on pages Wiring diagrams on page 197 ff.).
Additional connections
OUT
Monitoring output (semiconductor)
OUT D Door monitoring output (only CET3/4)
RST
Reset input
Category according to EN ISO 13849-1
Due to two redundant design semiconductor
outputs (safety outputs) with internal monitoring
suitable for:
f Category 4 / PL e according to EN ISO 13849-1
Important: To achieve the stated category in
accordance with EN ISO 13849-1, both safety
outputs (OA and OB) must be evaluated.
The category is dependent on the installation
position of the safety switch:
Installation position
Achievable
category and
PL according to
EN ISO 13849-1
Head upward
3 / PL e
Mechanical release
Is used for releasing the guard locking with the
aid of a tool. The mechanical release must be
sealed to prevent tampering (for example with
sealing lacquer).
Escape release (optional)
Is used for the manual release of the guard locking from within the danger area without tools.
Wire front release (optional)
The wire front release permits remote release of
the guard locking via a pull rope. Flexible routing
of the pull wire permits release of the guard locking in inaccessible installation situations.
The handle for the wire front release is not included. Please order separately (see page 174).
Lockout mechanism
The lockout mechanism can be used to prevent
maintenance personnel from being unintentionally
locked in the danger area, for example. In locked
position, the lockout mechanism prevents activation of guard locking. The lockout mechanism can
be secured in locking position with up to three
locks. The mechanical release can still be used.
194
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Cat.
4
PLe 1...20
LED 1
STATE
DIA
167
130
LED 2
13,4
42
30
16
Mechanical
release
43,6
67,2
CET.-AP...CRA...
74,5 4 mm
28
<15>
15
11
90
CET.-AP...CDA...
25
34
6.5
For M6 screw
DIN 1207 / ISO 4762
X2 (pin)
X1 (pin)
25
Actuator
CET-A-BWK-50X
Order separately
52
Lift tappet
with read head
10,5
26,5
Actuator CET-A-BWK-50X
for safety switch CET-AR
Dimension drawing
42
30
23
21
16
75
24
20
Release
by pressing
21,5
4 safety screws
M5x16 included
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
195
Dimension drawing
30,5
140
42
83
85
196
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
DC 24 V
Connected
load
RST
IA
0V UB
OB
OUT
UB
OA
IB
-F1
UCM
LED 2
LED 1
0V UCM
-F2
Safety
outputs
CET-AR
GND
DC 24 V
-F2
-F1
RST
IA
0V UB
OB
OUT
UB
OA
IB
UCM
LED 2
LED 1
0V UCM
START
Connected
load
Feedback
loop
Safety
outputs
CET-AR
GND
Connection example for separate operation, version with start button and feedback loop
DC 24 V
RST
IA
0V UB
OB
OUT
UB
OA
IB
-F1
UCM
LED 2
LED 1
0V UCM
-F2
Connected
load
Safety
outputs
CET-AR
GND
Connection example for separate operation, version without feedback loop and without teach-in input
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
197
2 x M12
X1.1
X1.2
X1.7
X1.6
X1.3
X1.4
Pin
Designation
Function
X 1.1
X 1.2
X 1.3
X 1.4
X 1.5
X 1.6
X 1.7
X 1.8
IB
UB
OA
OB
OUT
IA
0 V UB
RST
WH
BN
GN
YE
GY
PK
BU
RD
X 2.1
X 2.2
X 2.3
X 2.4
0 V UCM
LED 1
LED 2
UCM
BN
WH
BU
BK
X1.5
X1.8
X2.5
X2.1
X2.2
X2.4
X2.3
J
X 2.5
Y
-
GY
2 x M12
X1.1
X1.2
X1.7
X1.6
X1.3
X1.4
X1.5
X1.8
X2.5
X2.2
X2.3
Pin
Designation
Function
X 1.1
X 1.2
X 1.3
X 1.4
X 1.5
X 1.6
X 1.7
X 1.8
IB
UB
OA
OB
OUT
IA
0 V UB
RST
WH
BN
GN
YE
GY
PK
BU
RD
X 2.1
X 2.2
X 2.3
X 2.4
X 2.5
0 V UCM
LED 1
LED 2
UCM
FE
BN
WH
BU
BK
GY
X2.1
X2.4
198
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
2 x M12
X1.1
X1.2
X1.7
X1.6
X1.3
X1.4
Pin
Designation
Function
X 1.1
X 1.2
X 1.3
X 1.4
X 1.5
X 1.6
X 1.7
X 1.8
IB
UB
OA
OB
OUT
IA
0 V UB
RST
WH
BN
GN
YE
GY
PK
BU
RD
X 2.1
X 2.2
X 2.3
X 2.4
0 V UCM
OUT D
LED 1
UCM
BN
WH
BU
BK
X1.5
X1.8
X2.5
X2.1
X2.2
X2.4
X2.3
J
X 2.5
Y
-
GY
2 x M12
X1.1
X1.2
X1.7
X1.6
X1.3
X1.4
X1.5
X1.8
X2.5
X2.2
X2.3
Pin
Designation
Function
X 1.1
X 1.2
X 1.3
X 1.4
X 1.5
X 1.6
X 1.7
X 1.8
IB
UB
OA
OB
OUT
IA
0 V UB
RST
WH
BN
GN
YE
GY
PK
BU
RD
X 2.1
X 2.2
X 2.3
X 2.4
X 2.5
0 V UCM
OUT D
OUT
UCM
-
BN
WH
BU
BK
X2.1
X2.4
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
199
Wiring diagram
Lockout mechanism
Escape release
Teach-in input
Feedback loop
Double ramp
Single ramp
Multicode
Unicode
Door monitoring
output
Open-circuit
current principle
Order no./item
Closed-circuit
current principle
CET1
106275
CET1-AR-CDA-AH-50X-SG-106275
106616
CET1-AR-CRA-AH-50A-SG-106616
106159
CET1-AR-CRA-AH-50F-SG-106159
111766
CET1-AR-CRA-AH-50F-SG-C2333-111766
105802
CET1-AR-CRA-AH-50S-SG-105802
103418
CET1-AR-CRA-AH-50X-SG-103418
112121
CET1-AR-CRA-AH-50X-SG-C2333-112121
113320
CET1-AR-CRA-AH-50S-SG-C2290-113320
110241
CET1-AR-CRA-CH-50F-SG-110241
105764
CET1-AR-CRA-CH-50S-SG-105764
105763
CET1-AR-CRA-CH-50X-SG-105763
109231
CET1-AR-CDA-CH-50X-SG-109231
113272
CET1-AR-CRA-CH-50F-SG-C2333-113272
75 mm
75 mm
75 mm
A
A
A
A
A
5m
75 mm
A
A
75 mm
CET2
109075
CET2-AR-CRA-AH-50S-SG-109075
110240
CET2-AR-CRA-AH-50X-SG-110240
109941
CET2-AR-CRA-CH-50F-SG-C2312-109941
110082
CET2-AR-CRA-CH-50X-SG-110082
A
A
105 mm
* L1 = hose length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see page 218).
Wiring diagram
Lockout mechanism
Escape release
Feedback loop
Teach-in input
Single ramp
Double ramp
Multicode
Unicode
Door monitoring
output
Open-circuit
current principle
Order no./item
Closed-circuit
current principle
Ordering table CET.-AR--SG- with 2 plug connectors M12 and function earth connection
CET1
109015
CET1-AR-CRA-CH-50X-SG-C2290-109015
3m
* L1 = hose length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see page 218).
200
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
113965
CET3-AR-CRA-AH-50F-SG-113965
75 mm
114508
CET3-AR-CRA-AH-50F-SG-C2333-114508
75 mm
110114
CET3-AR-CRA-CH-50X-SG-C2290-110114
110905
CET3-AR-CRA-CH-50F-SG-C2290-110905
110906
CET3-AR-CRA-CH-50X-SG-110906
110907
CET3-AR-CRA-CH-50F-SG-110907
75 mm
112921
CET3-AR-CRA-CH-50F-SG-C2333-112921
75 mm
112992
CET3-AR-CRA-CH-50S-SG-112992
113958
CET3-AR-CRA-CH-50F-SG-C2357-113958
114090
CET3-AR-CDA-CH-50F-SG-114090
Wiring diagram
114512
CET3-AR-CRA-AH-50X-SG-C2333-114512
Lockout mechanism
113139
CET3-AR-CRA-AH-50X-SG-C2290-113139
Escape release
Feedback loop
Teach-in input
Double ramp
Single ramp
Unicode
109401
CET3-AR-CRA-AH-50X-SG-109401
Order no./item
Multicode
Door monitoring
output
Open-circuit
current principle
Closed-circuit
current principle
CET3
C
C
3m
75 mm
C
C
3m
3m
C
C
C
C
C
105 mm
C
C
CET4
111683
CET4-AR-CRA-AH-50X-SG-111683
111684
CET4-AR-CRA-CH-50X-SG-111684
113767
CET4-AR-CRA-CH-50X-SG-C2333-113767
114650
CET4-AR-CRA-CH-50F-SG-114650
113081
CET4-AR-CRA-CH-50S-SG-113081
114712
CET4-AR-CDA-CH-50X-SG-114712
113609
CET4-AR-CRA-CH-50X-SG-C2355-113609
75 mm
C
C
C
C
D
* L1 = hose length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see page 218).
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
201
RC18
With screen
bonding clamp
13
19
16
14
15
Function
UCM
VT
IA
RD
IB
GY
OA
RD/BU
OB
GN
UB
BU
RST
Reset input
GY/PK
GN/WH
OUT D
n.c.
YE/WH
10
OUT
Monitoring output
GY/WH
11
n.c.
BK
12
FE
Function earth
GN/YE
18
17
Designation
12
11
10
2
3
4
7
6
Pin
13
PK
14
n.c.
15
LED 1
BN/GY
BN/YE
16
LED 2
BN/GN
WH
17
n.c.
18
0V UCM
YE
19
0V UB
BN
202
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Wiring diagram
Lockout mechanism
Escape release
Feedback loop
Teach-in input
Double ramp
Single ramp
Multicode
Unicode
Door monitoring
output
Open-circuit
current principle
Order no./item
Closed-circuit
current principle
CET1
110203
CET1-AR-CRA-AH-50X-SH-110203
113022
CET1-AR-CRA-AH-50X-SH-C2290-113022
113021
CET1-AR-CRA-AH-50F-SH-C2353-113021
105 mm
110943
CET1-AR-CRA-AH-50F-SH-C2312-110943
105 mm
110204
CET1-AR-CRA-CH-50X-SH-110204
113255
CET1-AR-CRA-CH-50X-SH-113255
E
3m
3m
E
E
CET2
110205
CET2-AR-CRA-AH-50X-SH-110205
112466
CET2-AR-CDA-AH-50X-SH-112466
110206
CET2-AR-CRA-CH-50X-SH-110206
CET3
110103
CET3-AR-CRA-AH-50X-SH-110103
111725
CET3-AR-CRA-AH-50F-SH-C2312-111725
113024
CET3-AR-CRA-AH-50X-SH-C2290-113024
113023
CET3-AR-CRA-AH-50F-SH-C2353-113023
113151
CET3-AR-CRA-AH-50X-SH-C2333-113151
114088
CET3-AR-CRA-AH-50X-SH-C2290-114088
114505
CET3-AR-CRA-AH-50F-SH-C2333-114505
75 mm
113148
CET3-AR-CRA-AH-50F-SH-113148
75 mm
114647
CET3-AR-CDA-AH-50F-SH-114647
75 mm
110104
CET3-AR-CRA-CH-50X-SH-110104
E
E
105 mm
105 mm
3m
3m
5m
CET4
110201
CET4-AR-CRA-AH-50X-SH-110201
110202
CET4-AR-CRA-CH-50X-SH-110202
116285
CET4-AR-CRA-AH-50F-SH-116285
75 mm
* L1 = hose length; cable length = L1 + 1 m. Important: Handle must be ordered separately (see page 218).
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
203
Value
min.
General
Material, ramp
Material, safety switch housing
Installation position
Degree of protection
with plug connector M12
with plug connector RC18
Safety class
Degree of contamination
Mechanical life
Ambient temperature at UB
Actuator approach speed, max.
Locking force Fmax
Locking force FZh
in acc. with GS-ET-19
Mass
Degrees of freedom (actuator in recess) X, Y, Z
Connection type (depending on version)
Operating voltage UB (reverse-polarity protected, regulated,
residual ripple < 5%)
Current consumption IB
For the approval according to UL the following applies
Switching load according to UL
External fuse (operating voltage UB)
External fuse (solenoid operating voltage UCM)
max.
Stainless steel
Die-cast aluminum
Any (recommendation: switch head downward)
IP 67
IP65 with plug connector RC 18
(screwed tight with the related mating connector)
III
3
1 x 106 operating cycles
20
6,500
-20
+55
C
m/min
N
Approx. 1.0
X, Y 5; Z 4
2 plug connectors M12, 5 and 8-pin
1 plug connector RC 18, 19-pin (as yet no UL approval)
kg
mm
24 15% (PELV)
V DC
80
Operation only with UL class 2 power supply, or equivalent measures
DC 24 V, class 2
0.25
2
0.5
8
mA
Unit
typ.
75
according to EN 60947-5-2
acc. to EN IEC 60947-5-3
Semiconductor outputs, p-switching, short circuit-proof
UB - 1.5
0
1
UB
1
200
DC-13 24V 200mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
0.5
10
(p-switching, short circuit-proof)
0.8 x UB
UB
50
15
0
UCM
1
A
A
V
V DC
mA
Hz
%
V DC
mA
V
DC 24 V +10%/-15%
480
10
100
LED1 red, LED2 green
20.4
Head downward or horizontal
4
e
3.1 x 10 -9 / h
20
mA
W
%
26.4
Head upward
3
e
4,29 x 10 -8 / h
20
V DC
years
1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) Can vary depending on version. See data sheet.
Actuator
Parameter
Value
min.
Housing material
Installation position
Degree of protection according to IEC/EN 60529
Mechanical life
Ambient temperature
Locking force, max. (locked)
Mass
Stroke max.
Power supply
204
-20
typ.
Stainless steel
Active face opposite read head
IP67
1 x 106 operating cycles
6,500
Approx. 0.25
15
Inductive, via read head
Unit
max.
+55
C
N
kg
mm
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Flying lead
M12 female connector 8-pin
Flying lead
M12 female connector 5-pin
Dimension drawing
View of connection side
5
2
1
2
Socket
4,1
6
5,9
4,1
4,1
Cable end
sleeves
5,9
Plug
4
3
1 = WH
2 = BN
3 = GN
4 = YE
5 = GY
6 = PK
7 = BU
8 = RD
f
f
f
f
f
f
f
f
IB
UB
OA
OB
OUT
IA
OV
RST
1 = WH
2 = BN
3 = GN
4 = YE
5 = GY
6 = PK
7 = BU
8 = RD
f
f
f
f
f
f
f
f
IB
UB
OA
OB
OUT
IA
OV
RST
1 = BN f
CES-AR
UB
2 = WH f
OA
3 = BU f
0V
4 = BK f
5 = GY f
OB
RST
CET-AR
0 V UCM
LED1/
OUT D
LED1/
LED2
UCM
J/Y/n.c.
1 = BN f
CES-AR
UB
2 = WH f
OA
3 = BU f
0V
4 = BK f
5 = GY f
OB
RST
CET-AR
0 V UCM
LED1/
OUT D
LED1/
LED2
UCM
J/Y/n.c.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
205
Comment
M8 female connector 8-pin, length 5 m
M8
8
pin
M12
5
pin
M12
8
pin
Order no./item
110933
C-M08F08-08X014PV05,0-ES-110933
110934
C-M08F08-08X014PV10,0-ES-110934
110935
C-M08F08-08X014PV15,0-ES-110935
111603
C-M08F08-08X014PV20,0-ES-111603
100183
C-M12F05-05X034PV05,0-MA-100183
100184
C-M12F05-05X034PV10,0-MA-100184
100185
C-M12F05-05X034PV20,0-MA-100185
100180
C-M12F05-05X034PV05,0-M12M05-100180
100181
C-M12F05-05X034PV10,0-M12M05-100181
100182
C-M12F05-05X034PV20,0-M12M05-100182
100177
C-M12F08-08X025PV05,0-MA-100177
100178
C-M12F08-08X025PV10,0-MA-100178
100179
C-M12F08-08X025PV20,0-MA-100179
M8
8
pin
M12
8
pin
M12
5
pin
206
Comment
M8 female connector 8-pin, length 5 m
Order no./item
106671
C-M08F08-08X014PU05,0-ES-106671
106672
C-M08F08-08X014PU10,0-ES-106671
106673
C-M08F08-08X014PU20,0-ES-106673
C-M12F08-08X025PU10,0-MA-113189
C-M12F08-08X025PU10,0-MA-113188
113189
113188
113190
C-M12F05-05X025P10,0-MA-113190
113187
C-M12F05-05X025P10,0-MA-113187
115566
C-M12F05-05X025P10,0-M12M05-115566
115565
C-M12F05-05X025P10,0-M12M05-115565
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
Value
typ.
8-pin M8 female connector, straight
Screw terminal
8 x 0.14
TPU, self-extinguishing
PVC 4.5
min. 5 x cable diameter
max.
Unit
mm
mm
mm
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
Value
typ.
8-pin M8 female connector, straight
Screw terminal
8 x 0.14
TPU
PUR 5
min. 5 x cable diameter
max.
Unit
mm
mm
mm
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
Value
typ.
5-pin M12 female connector, straight
Screw terminal
5 x 0.34
TPU, self-extinguishing
PVC 5.9
min. 5 x cable diameter
max.
Unit
mm
mm
mm
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
Value
typ.
8-pin M12 female connector, straight
Screw terminal
8 x 0.25
TPU, self-extinguishing
PVC 5.9
min. 5 x cable diameter
max.
Unit
mm
mm
mm
Technical data for M12 connection cable PUR, 5-core, with female connector, angled
Parameter
min.
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
Value
typ.
5-pin M12 female connector, angled
Screw terminal
5 x 0.25
TPU, self-extinguishing
PUR 4.1
min. 5 x cable diameter
max.
Unit
mm
mm
mm
Technical data for M12 connection cable PUR, 8-core, with female connector, angled
Parameter
Plug connector
Connection
Conductor cross-section
Material, connector housing
Material, outer sheath
Static bending radius
min.
Value
typ.
8-pin M12 female connector, angled
Screw terminal
8 x 0.25
TPU, self-extinguishing
PUR 5.2
min. 5 x cable diameter
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
max.
Unit
mm
mm
mm
207
Dimension drawing
78
Inserted
92
Inserted
With screen
bonding clamp
71
With
screen
bonding
clamp
85
12
1
17
19
14
12
11,6 0,3
17
19
14
16
15
11
18
13
15
View of
connection side,
socket
26
SW20
10
16
11,4 0,3
26
11
18
13
10
9
8
View of
connection side,
socket
Dimension drawing
M20x1,5
70
12
1
12
2
50,2
18
13
17
19
14
11
16
15
9
8
View of
connection side,
socket
SW20
SW24
10
11,4 0,3
62
With
screen
bonding
clamp
50
26
60
58
With screen
bonding clamp
18
13
11
17
19
14
16
15
10
9
8
View of
connection side,
socket
26
Conductor cross-section
[mm]
Pin
Core color
Conductor cross-section
[mm]
VT
0.5
RD
0.5
11
BK
0.5
12
GN/YE
GY
1.0
0.5
13
PK
0.5
RD/BU
0.5
14
BN/GY
0.5
GN
0.5
15
BN/YE
0.5
BU
1.0
16
BN/GN
0.5
GY/PK
0.5
17
WH
0.5
GN/WH
0.5
18
YE
0.5
YE/WH
0.5
19
BN
1.0
10
GY/WH
0.5
Pin
208
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Order no./item
092761
RC18EF1,5M-C1825
092816
RC18EF3M-C1825
077014
RC18EF6M-C1825
077015
RC18EF8M-C1825
092898
RC18EF10M-C1825
077016
RC18EF15M-C1825
092726
RC18EF20M-C1825
092727
RC18EF25M-C1825
095993
RC18EF30M-C1825
092883
RC18EF1,5MF-C1825
092884
RC18EF3MF-C1825
092885
RC18EF6MF-C1825
092886
RC18EF8MF-C1825
092887
RC18EF10MF-C1825
092888
RC18EF15MF-C1825
092889
RC18EF20MF-C1825
092890
RC18EF25MF-C1825
109681
RC18EF30MF-C1825
1.5
3
6
Female connector RC18
with cable PUR
for CET-AR
18-pin + PE
8
10
15
20
25
30
1.5
3
6
8
10
15
20
25
30
Designation
8
10
15
20
25
1.5
3
6
8
10
15
20
25
Order no./item
Cable outlet left
092906
RC18WF1,5ML-C1825
092908
RC18WF3ML-C1825
077018
RC18WF6ML-C1825
077019
RC18WF8ML-C1825
092901
RC18WF10ML-C1825
077020
RC18WF15ML-C1825
092910
RC18WF20ML-C1825
092912
RC18WF25ML-C1825
092891
RC18WF1,5MLF-C1825
092893
RC18WF3MLF-C1825
092697
RC18WF6MLF-C1825
092895
RC18WF8MLF-C1825
092699
RC18WF10MLF-C1825
092701
RC18WF15MLF-C1825
092704
RC18WF20MLF-C1825
092724
RC18WF25MLF-C1825
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
209
Value
min.
typ.
max.
Unit
Connection
Screw terminal
Conductor cross-section
16 x 0.5 / 3 x 1.0
mm
CuZn
Polyurethane
Bending radius
mm
Technical data for female connector RC18, straight/angled, with halogen-free cable
Parameter
Plug connector
Connection
Conductor cross-section
Value
min.
typ.
Screw terminal
16 x 0.5 / 3 x 1.0
Polyurethane, halogen-free
Polyurethane, halogen-free
Bending radius
210
Unit
max.
mm
CuZn
min. 10 x cable diameter
mm
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
59
Inserted
With screen
bonding clamp
52
12
26
M20x1,5
1
2
3
18
13
11
17
10
19
14
16
15
8
5
SW20
View of
connection side,
socket
With screen
bonding clamp
52
52
26
12
18
13
11
17
10
19
14
16
15
8
5
View of
connection side,
socket
SW20
SW24
58
60
26
1
2
M20x1,5
Ordering table
Series
Comment
Order no.
RC18 1)
18-pin + PE
EF
Female connector
WF
Female connector angled
Replacement pin crimp contacts
Conductor cross-section 19 x 0.75 - 1 mm2
074616
RC18EF
074617
RC18WF
094309
Pin crimp contact RCM
Technical data
Value
Parameter
Unit
min.
Grip material
typ.
max.
CuZn nickel-plated
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
IP65 (inserted)
211
Dimension drawing
Y-distributor M12
1 x 8-pin, 2 x 5-pin
Socket
3
Socket
1
2 3 1
View on
connection side
M12x1
15,1
M12x1
45
15
41
15
7
( 45
(gure similar)
Length A
M 12x1
097627
M 12x1
44
max. 45
33
14,6
M12x1
14,5
Plug
Socket
1
20,5
35,1
2
1
Wiring
bridging plug
Plug
Socket
1
2
3
4
15
M 12x1
Pin
Function
Pin
Function
Pin
Function
Pin
Function
UB
UB
UB
UB
OA
IA
OA
IA
0V
0V
0V
0V
OB
IB
OB
IB
RST
RST
RST
RST
Important: Switch chains must always be terminated with a bridging plug. Switch chains up to maximum 200 m are allowed taking into account the
voltage drop due to the cable resistance (see operating instructions of your AR device).
Ordering table
Series
Comment
Bridging plug
Y-distributor M12
212
M12,
1 x 8-pin, 2 x 5-pin
Length A = 200 mm
Length A = 1,000 mm
Order no.
097645
Bridging plug
111696
Y-distributor with connection cable
112395
Y-distributor with connection cable
097627
Y-distributor M12
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Unit
min.
Grip material
typ.
max.
TPU, self-extinguishing
CuZn nickel-plated
IP68 (inserted)
Unit
min.
Grip material
typ.
max.
TPU, self-extinguishing
CuZn nickel-plated
PVC
IP67 (inserted)
Unit
min.
Grip material
Threaded bushing/union nut material
typ.
max.
TPU, self-extinguishing
CuZn nickel-plated
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
IP67 (inserted)
213
Dimension drawing
82
65
42
37
20
45
For M6 screw
EN ISO 4762
20
39
58
205
138
6,5
For M5 screw
(12x)
For M6 screw
(12x)
9,5
22,5
27
Prole marking 45 x 45
Material thickness 10 mm
Material thickness 10 mm
Ordering table
Designation
Use
Order no./item
106695
EMP-L-CET
106694
EMP-B-CET
12,5
45
214
15
40
45 15
45
40
15
40
45
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Version/usage
Packaging unit
[qty.]
Order no.
Safety screws
M4 x 14
(small head)
Actuator
CES-A-BBA, CES-A-BCA
20
071863
Safety screws
M4 x 14
(large head)
100
086232
Safety screws
M5 x 16
Actuator
CES-A-BRN, CET-A-BWK
100
073456
Safety screws
M5 x 10
100
073455
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
215
30
16,7
35,5
Dimension drawing
Emergency unlocking
Using the emergency unlocking the safety switch
can be unlocked manually. In the locked position of the emergency unlocking, a ball detent
mechanism prevents unintentional unlocking of
the safety switch due to vibration or similar.
In the unlocked position of the emergency unlocking, an integrated bolt engages in a bore on the
ange. To reset the emergency unlocking, rst the
bolt must be pressed inwards, out of the detent
mechanism, using a tool.
The emergency unlocking can be lead-sealed
(lead seal kit order no. 087256).
5,8
Emergency unlocking
for safety switch CET
71
30,4
25
20
Ordering table
216
Designation
Use
Version
Replacement key
Emergency unlocking
Order no./item
098850
Mechanical key release
099434
Replacement key
103714
Emergency unlocking CET
087256
Lead seal kit for emergency unlocking
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Cover
With the CET cover, tampering with the safety
switch CET is effectively prevented.
The cover prevents the use of simple tools to
manually press up the actuator.
Cover
for safety switch and actuator CET
Cover for door hinge on left mirror image
70
1
87
60
70
64
20
30
7,
5
2
6,5 (2x)
Double ramp
The ramp can be approached from two sides. It
can be passed over, e.g. for sliding doors.
Double ramp
for safety switch CET
Ordering table
Designation
Use
Cover
Double ramp
Version
door hinge right
door hinge left
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Order no./item
098808
CET cover right
098807
CET cover left
114091
Double ramp for CET
217
Actuator CET-A-BWK-50X
for safety switch CET-AR
4 safety screws
M5x16 included
Ordering table
Designation
Actuator for CET
Handle for wire front release
218
Version/usage
Order no./item
096327
CET-A-BWK-50X
099795
Handle for wire front release
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
8 RST
IA
0V
5 OUT
OA
OB
IB
UB
-F1
Connected
load
Safety
outputs
Plug-connector
(8-pin)
CES-AR #1
GND
T-Stck/T-Connector
T-Stck/T-Connector
T-Stck/T-Connector
Stift/
Buchse/
Stift/
Buchse/
Stift/
Buchse/
connector
conector
connector
conector
connector
conector
(male)
(female)
(male)
(female)
(male)
(female)
Brckenstecker /
Short-circuit plug
Safety
outputs
OA
3
Stift/
conetctor
(male)
Safety
outputs
Plug-connector
Plug-connector
(8-pin)
(8-pin)
CES-AR #n
IB
UB
OA
OB
8 RST
0V
7
IA
Safety
outputs
IB
UB
OA
OB
IB
UB
5 OUT
8 RST
IA
0V
5 OUT
OB
8 RST
IA
0V
5 OUT
-F1
Plug-connector
(8-pin)
CES-AR #n-1
CES-AR #1
Connected
load
GND
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
219
Connected
load
RST
IA
0V UB
OB
OUT
UB
OA
IB
-F1
UCM
LED 2
LED 1
0V UCM
-F2
Safety
outputs
CET-AR
GND
-F1
T-Stck/T-Connector
Stift/
connector
(male)
Buchse/
connector
(female)
Brckenstecker /
Short-circuit plug
CES-AR #n-1
Stift/
connector
(male)
IA
RST
8
0V
OB
OUT
OA
IB
UB
RST
IA
0V
OB
OUT
OA
IB
UB
Plug-connector
(8-pin)
RST
IA
0V UB
OB
OUT
OA
IB
UB
UCM
LED 2
LED 1
0V UCM
Stift/
connector
(male)
Connected
load
T-Stck/T-Connector
Buchse/
connector
(female)
-F2
START
Plug-connector
(8-pin)
CES-AR #1
Safety
outputs
Feedback
loop
CET-AR #n
GND
Important: The subsystem CET-AR complies with PL e in accordance with EN 13849-1. To integrate the subsystem in a category 3 or 4 structure,
it is necessary to monitor the downstream load (the feedback loop must be monitored).
These examples show only an excerpt that is relevant for connection of the CET system. The example illustrated here does not show complete
system planning. The user is responsible for safe integration in the overall system.
220
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Cat.
4
PLe 1...12
Dimension drawing
13
23
33
43
OUT
AR
14
24
34
44
Y1
DIA 0V +UB
Y2
+UB
EUCHNER
Safety Unit
CES-AR
RESET
O2 O3
O4
O5
O6
O7
O8
IA
IB
UB
AR
0V
AR
O1
Block diagram
UB
UB
X6:4 X5:4
IA
IB
X8:1
X8:2
Y1
Y2
switch chain
13
23
33
43
14
24
34
44
Feedback
Loop
DC 24 V
098225
X6:3
0V
CES- AR
X6:2
X8:3
DIA
X8:4
UB AR
X3:1 X3:2 X3:3 X3:4 X7:1 X7:2 X7:3 X7:4 X4:1 X4:2 X4:3 X4:4
0V AR
O1
O2
O3
O4
O5
O6
O7
O8
O9
X6:1
OUT AR
Terminal assignment
13
23
33
43
OUT
AR
14
24
34
44
Y1
DIA 0V +UB
Y2
+UB
EUCHNER
Safety Unit
DIA OUT STATE
13
23
33
43
OUT
AR
14
24
34
44
Y1
DIA 0V +UB
Y2
+UB
EUCHNER
Safety Unit
DIA OUT STATE
CES-AR
CES-AR
RESET
RESET
O4
O5
O6
O7
O8
IA
IB
UB
AR
0V
AR
O1
O2 O3
O2 O3
O4
O5
O6
O7
O8
IA
IB
UB
AR
0V
AR
O1
Series
Order no.
CES-AR-AES-12
4 / PL e
098225
CES-AR-AES-12
104776
CES-EA-TC-AK08-104776
112629
CES-EA-TC-KK08-112629
Connection sets
for evaluation unit CES-AR-AES-12
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
CES-AR-AES
Ordering table
221
Safety switches
CES-AR-C01
from V1.1.2 (see rating plate on the device)
CES-AR-CR2
from V1.1.2 (see rating plate on the device)
AR evaluation unit
CES-AR-AES-12
098225
CES-AR-CL2
from V1.1.2 (see rating plate on the device)
CET1/2-AR
from V1.1.2 (see rating plate on the device)
CET3/4-AR
from V1.0.0 (see rating plate on the device)
222
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Parameter
min.
typ.
Housing material
max.
Unit
Plastic PA6.6
Dimensions
114 x 99 x 22.5
Mass
mm
0.25
kg
Ambient temperature at UB = DC 24 V
--20
+55
80
IP20
Degree of contamination
Mounting
0.14
2.5
24 10% (PELV)
mm
V DC
1.2 1)
2.5
A gG
Safety contacts
AC/DC
21 60 V
300
- at switching voltage
AC/DC
5 30 V
10
6,000
- at switching voltage
AC 5 230 V
5,000
10
mA
250
kV
according to EN 60947-5-2
10 x 106
10
mA
600
Monitoring outputs (O1 O12, DIA and OUT AR, semiconductor outputs, p-switching, short circuit-proof)
- Output voltage
0.8 x UB
UB
V DC
- Max. load
20
mA
- Switching frequency
Hz
LOW
HIGH
15
UB
HIGH
10
V DC
mA
Max. 12
according to EN 60947-5-3
0.1 A
Category
3A
e
1.5 x 10-8
PFHd
Mission time
Number of switching cycles/year
1A
720,000
20
540,000
years
107,000
1) Taking into account the load currents at the monitoring outputs (20 mA each)
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
223
224
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Bolts provide mechanical guard locking, i.e. the monitoring circuit cannot
be opened unintentionally by moving the hinged door.
f Accidental stoppage of the machine is prevented
If the safety doors are shaken, the force is transmitted to the mechanically strong bolt and not to the safety switch.
f Safety switches and actuators are thus protected against damage
By using bolts, persons who must enter hazardous areas, e.g. for
servicing and setup work, can protect themselves. By attaching one
or more simple padlocks to the bolt in the open position, the movable
safety guards cannot be closed and thus the dangerous states cannot
be triggered.
f The operator is protected
Standard aluminum proles are frequently used for safety guards. The
bolts are particularly easy to t here.
f Optimal adaptation of the bolts to the market standard
When the EUCHNER safety door bolts are opened intentionally, the actuator mounted on the handle is pulled out of the operating distance of the
safety switch or read head.
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
225
Bolt CES-A-A
Dimension drawing
40
15
110
20
For M6 screw
Special features
f Easy mounting of the read head
on the bracket for the bolt tongue
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
f Ball detent mechanism in closed
bolt position
- protection against vibration
60
42
70
14
84
12
For M6 screw
CES
Stop screw
locked
For M6 screw
For M6 screw
69
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
30
58
135
62
Notes
f CES actuator integrated in the
bolt tongue
f Order read head and evaluation
unit separately
f Other bolt types on request
Bolt tongue
Bracket
Ordering table
226
Designation
Detent mechanism
Version
Order no.
Bolt CES-A-A
076487
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Bolt CES-A-A/F
Dimension drawing
40
15
110
For M6 screw
20
Special features
f Easy mounting of the read head
on the bracket for the bolt tongue
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
f Bolt with detent mechanism
- bolt latches in open position to
prevent unintended closing
15
60
42
70
84
12
For M6 screw
Stop
screw
locked
For M6 screw
100
85
Door hinged
on the right
69
30
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
120
For M6 screw
1)
ca.25
58
135
62
120
Notes
f CES actuator integrated in the
bolt tongue
f Order read head and evaluation
unit separately
85
100
Door hinged
on the left
1) Bolt with detent mechanism. Latches in open position and prevents unintentional closing of the bolt.
Unlocked by pulling the detent knob upward.
Ordering table
Designation
Detent mechanism
Version
Order no.
Bolt CES-A-A/F
086173
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
227
40
20
110
15
For M6 screw
20
70
M 5 (4x)
11
124
196
220
M5
40
For M6 screw
8
33
62
Notes
f Order read head, actuator and
evaluation unit separately
f Other bolt types (e.g. with mechanical detent mechanism in
closed bolt position) on request
4 safety screws
included
81
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f No additional door handle necessary
Stop screw
locked
80
Special features
f Easy read head mounting
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
93
14
42
18
30
For M6 screw
60
<59>
<58>
<136>
Ordering table
228
Designation
Detent mechanism
Version
Order no.
Bolt CEM-A
Without
097955
Bolt CEM-C
Without
097957
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Bolt CES-A-C
Dimension drawing
40
15
110
20
For M6 screw
both sides
42
14
170
190
Special features
f Easy mounting of the safety
switch on the bracket for the
bolt tongue
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
f Ball detent mechanism in closed
bolt position
- protection against vibration
Detent mechanism
against accidental
opening (vibration)
40
69
10
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
Notes
f CES actuator integrated in the
bolt tongue
f Order safety switch separately
f Other bolt types (e.g. with mechanical detent mechanism in
closed bolt position) on request
60
12
For M6 screw
58
62
135
Ordering table
Designation
Detent mechanism
Version
Order no.
Bolt CES-A-C
082220
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
229
Dimension drawing
40
15
110
20
For
M6 screw
For M6 screw
12
60
170
190
14
42
Detent mechanism
against accidental
opening (vibration)
Special features
f Easy mounting of the safety
switch on the bracket for the
bolt tongue
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
f Bolt with detent mechanism
- bolt latches in open position to
prevent unintended closing
f Ball detent mechanism in closed
bolt position
- protection against vibration
1)
40
69
10
Door hinged
on the right
61
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
135
60
Door hinged
on the left
Notes
f CES actuator integrated in the
bolt tongue
f Order safety switch separately
1) Bolt with detent mechanism. Latches in open position and prevents unintentional closing of the bolt.
Unlocked by pulling the detent knob upward.
Ordering table
230
Designation
Detent mechanism
Version
Order no.
Bolt CES-A-C/F
098357
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Dimension drawing
For M6 screw
For
M6 screw
CES actuator
pressed into bolt tongue
Special features
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
f Bolt with detent mechanism
Ball detent mechanism in closed
bolt position
- protection against vibration
Detent mechanism
against accidental
opening (vibration)
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
For M6 screw
Safety guard frame
(40 x 40)
Notes
f CES actuator integrated in the
bolt tongue
f Safety switch
CES-AR-C01-AH-SA-098941 or
CES-AP-C01-AH-SB-111145
included
f You will nd information on the
safety switch on page 182
Door hinged
on the right
1) Bolt with detent mechanism. Latches in closed position and prevents unintended opening of the bolt.
Ordering table
Designation
Detent mechanism
Bolt CES-AC-AR-C01-AH-SA-C2296
Bolt CES-AC-AP-C01-AH-SB-C2296
Version
Bolt with pre-assembled safety
switch
CES-AR-C01-AH-SA-098941
for doors hinged on the right or left
Bolt with pre-assembled safety
switch
CES-AP-C01-AH-SB-111145
for doors hinged on the right or left
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Order no.
109358
113986
231
Dimension drawing
For M6 screw
For
M6 screw
CES actuator
pressed into bolt tongue
Special features
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
f Bolt with detent mechanism
- bolt latches in open position to
prevent unintended closing
f Ball detent mechanism in closed
bolt position
- protection against vibration
Detent mechanism
against accidental
opening (vibration)
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
Door hinged
on the right
Notes
f CES actuator integrated in the
bolt tongue
f Safety switch
CES-AR-C01-AH-SA-098941
included
f You will nd information on the
safety switch on page 182
Safety plate
Door hinged
on the left
1) Bolt with detent mechanism. Latches in open position and prevents unintentional closing of the bolt.
Unlocked by pulling the detent knob upward.
Ordering table
Designation
Bolt CES-ACR1-AR-C01-AH-SA-104028
232
Detent mechanism
Version
Order no.
104028
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Bolt CES-AC/F-A.-C01-AH-S.-
Dimension drawing
For M6 screw
For M6 screw
Special features
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
f Bolt with detent mechanism
- bolt latches in open position to
prevent unintended closing
f Ball detent mechanism in closed
bolt position
- protection against vibration
Detent mechanism
against accidental
opening (vibration)
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
Notes
f CES actuator integrated in the
bolt tongue
f Safety switch
CES-AR-C01-AH-SA-098941 or
CES-AP-C01-AH-SB-111145 or
CES-AP-C01-CH-SB-111708 included
f Information about the safety
switches can be found on pages
130 and 182
Safety plate
Door hinged
on the left
1) Bolt with detent mechanism. Latches in open position and prevents unintentional closing of the bolt.
Unlocked by pulling the detent knob upward.
Ordering table
Designation
Detent mechanism
Bolt CES-AC/F-AR-C01-AH-SA-105619
Bolt CES-AC/F-AP-C01-AH-SB-116246
Bolt CES-AC/F-AP-C01-CH-SB-115732
Version
Bolt with pre-assembled safety switch
CES-AR-C01-AH-SA-098941
and safety plate
for doors hinged on the right or left
Bolt with pre-assembled safety switch
CES-AP-C01-AH-SB-111145
and safety plate
for doors hinged on the right or left
Bolt with pre-assembled safety switch
CES-AP-C01-CH-SB-111708
and safety plate
for doors hinged on the right or left
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Order no.
105619
116246
115732
233
Dimension drawing
For M6 screw
For
M6 screw
CES actuator
pressed into bolt tongue
Special features
f Multicode safety switch (no
teach-in operation necessary)
f Bolt with detent mechanism
Ball detent mechanism in closed
bolt position
- protection against vibration
Detent mechanism
against accidental
opening (vibration)
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
Door hinged
on the right
Notes
f CES actuator integrated in the
bolt tongue
f Safety switch
CES-AP-C01-CH-SB-106798 or
CES-AP-C01-CH-SB-111708 inf
cluded
You will nd information on the
safety switch on page 130
1) Bolt with detent mechanism. Latches in closed position and prevents unintended opening of the bolt.
Ordering table
Designation
234
Detent mechanism
Bolt CES-AC-AP-C01-CH-SB-110355
Bolt CES-AC-AP-C01-CH-SB-110354
Version
Bolt with pre-assembled safety switch
CES-AP-C01-CH-SB-106798
for doors hinged on the right or left
Bolt with pre-assembled safety switch
CES-AP-C01-CH-SB-111708
for doors hinged on the right or left
Order no.
110355
110354
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Bolt CET-A-C
Dimension drawing
75
15
40
For M6 screw
20
110
20
20
65,75
26
42
60
21,3
41,25
21,3
For M6 screw
both sides
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
For M6 screw
30
Safety guard frame
(40 x 40)
Notes
f Order read head, actuator and
evaluation unit separately
f Other bolt types (e.g. with mechanical detent mechanism in
closed bolt position) on request
f The installation position of the
safety switch/read head affects
the safety category (see pages
63, 148 and 194)
21
Door hinged
on the right
80
70
Special features
f Easy assembly
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
130
290
270
64
136
(65,5)
199
202
Ordering table
Designation
Detent mechanism
Version
Order no.
Bolt CET-A-C
Without
Closed position: none
Open position: detent knob
104309
Bolt CET-A-C/F
Actuator CET
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
106172
096327
CET-A-BWK-50X
235
Dimension drawing
75
For M6 screw
15
110
40
20
20
For M6 screw
both sides
290
Special features
f Allows door to be opened outward
and inward, making it particularly
suitable for swing doors
f Easy assembly
f Uniquely coded actuator (oneoff)
- maximum protection against
tampering
42
60
M5 (4x)
104
34
270
130
65,75
60
26
16
41,25
21,3
20
21,3
36,5
M6 (4x)
For M6 screw
30
Features
f Easily tted to standard aluminum
proles and machine covers by
screw connection
f Distinctive yellow color for easy
recognition
f Symmetrical design for doors
hinged on the right or left
f No additional door handle necessary
70
Notes
f Order read head, actuator and
evaluation unit separately
f Other bolt types (e.g. with mechanical detent mechanism in
closed bolt position) on request
f The installation position of the
safety switch/read head affects
the safety category (see pages
63, 148 and 194)
80
21
Door hinged
on the right
64
136
87,5
202
Ordering table
Designation
236
Detent mechanism
Version
Order no.
Bolt CET-A-C-C2308
Without
109672
Actuator CET
096327
CET-A-BWK-50X
Subject to technical modications; no responsibility is accepted for the accuracy of this information.
Item Index
Index by item designation
Item
AM-SET-PP-119690
AM-SET-PPB-119694
Bolt CEM-A
Bolt CEM-C
Bolt CES-A-A
Bolt CES-A-A/F
Bolt CES-A-C
Bolt CES-A-C/F
Bolt CES-AC/F-AP-C01-AH-SB-116246
Bolt CES-AC/F-AP-C01-CH-SB-115732
Bolt CES-AC/F-AR-C01-AH-SA-105619
Bolt CES-AC-AP-C01-AH-SB-C2296
Bolt CES-AC-AP-C01-CH-SB-110354
Bolt CES-AC-AP-C01-CH-SB-110355
Bolt CES-AC-AR-C01-AH-SA-C2296
Bolt CES-ACR1-AR-C01-AH-SA-104028
Bolt CET-A-C
Bolt CET-A-C/F
Bolt CET-A-C-C2308
Bridging plug
BS4C1851
C-M05F03-02X014PV05,0-ES-105555
C-M05F03-02X014PV10,0-ES-105556
C-M05F03-02X014PV20,0-ES-105559
C-M08F03-02X025PU05,0-ES-084762
C-M08F03-02X025PU10,0-ES-084763
C-M08F03-02X025PU10,0-ES-098590
C-M08F03-02X025PU15,0-ES-084764
C-M08F03-02X025PU20,0-ES-084765
C-M08F03-02X025PU25,0-ES-084766
C-M08F03-02X025PV03,0-ES-077935
C-M08F03-02X025PV05,0-ES-077793
C-M08F03-02X025PV10,0-ES-077767
C-M08F03-02X025PV10,0-ES-084701
C-M08F03-02X025PV20,0-ES-077716
C-M08F03-02X025PV25,0-ES-077717
C-M08F03-02X025PV25,0-ES-099998
C-M08F04-04X025PV05,0-ES-088813
C-M08F04-04X025PV10,0-ES-084703
C-M08F04-04X025PV10,0-ES-088814
C-M08F04-04X025PV15,0-ES-088815
C-M08F04-04X025PV25,0-ES-095035
C-M08F04-04X034PU05,0-ES-116049
C-M08F04-04X034PU10,0-ES-116050
C-M08F04-04X034PU20,0-ES-116051
C-M08F08-08X014PU05,0-ES-106671
C-M08F08-08X014PU10,0-ES-106671
C-M08F08-08X014PU20,0-ES-106673
C-M08F08-08X014PV05,0-ES-110933
C-M08F08-08X014PV10,0-ES-110934
C-M08F08-08X014PV15,0-ES-110935
C-M08F08-08X014PV20,0-ES-111603
C-M08M04-04X025PV02,0-ES-088841
C-M08M04-04X025PV05,0-ES-088842
C-M08M04-04X025PV10,0-ES-084705
C-M08M04-04X025PV10,0-ES-088843
C-M08M04-04X025PV15,0-ES-088844
C-M12F05-05X025P10,0-M12M05-115565
C-M12F05-05X025P10,0-M12M05-115566
C-M12F05-05X025P10,0-MA-113187
C-M12F05-05X025P10,0-MA-113190
C-M12F05-05X034PV05,0-M12M05-100180
Order no.
119690
119694
097955
097957
076487
086173
082220
098357
116246
115732
105619
113986
110354
110355
109358
104028
104309
106172
109672
097645
077435
105555
105556
105559
084762
084763
098590
084764
084765
084766
077935
077793
077767
084701
077716
077717
099998
088813
084703
088814
088815
095035
116049
116050
116051
106671
106672
106673
110933
110934
110935
111603
088841
088842
084705
088843
088844
115565
115566
113187
113190
100180
Page
163
163
228
228
226
227
229
230
233
233
233
231
234
234
231
232
235
235
236
212
70
64
64
64
65
65
65
65
65
65
65
65
65
65
65
65
65
66, 157
66, 157
66, 157
66, 157
66, 157
66, 157
66, 157
66, 157
206
206
206
206
206
206
206
67
67
67
67
67
157, 206
157, 206
157, 206
157, 206
157, 206
Item
C-M12F05-05X034PV05,0-MA-100183
Order no.
100183
C-M12F05-05X034PV10,0-M12M05-100181
C-M12F05-05X034PV10,0-MA-100184
100181
100184
C-M12F05-05X034PV20,0-M12M05-100182
C-M12F05-05X034PV20,0-MA-100185
100182
100185
C-M12F08-07X025PU10,0-MA-102218
C-M12F08-07X025PU25,0-MA-103782
C-M12F08-07X025PV10,0-MA-099633
C-M12F08-07X025PV10,0-MA-100456
C-M12F08-07X025PV20,0-MA-099634
C-M12F08-07X025PV20,0-MA-105071
C-M12F08-07X025PV25,0-MA-103115
C-M12F08-08X025PU10.0-MA-113188
C-M12F08-08X025PU10.0-MA-113189
C-M12F08-08X025PV05,0-MA-100177
C-M12F08-08X025PV05,0-MW-077751
C-M12F08-08X025PV10,0-MA-100178
C-M12F08-08X025PV10,0-MW-077752
C-M12F08-08X025PV15,0-MW-077753
C-M12F08-08X025PV20,0-MA-100179
C-M12F08-08X025PV20,0-MW-077871
C-M12F08-08X025PV25,0-MW-077872
C-M12F08-08X025PV50,0-MW-077873
C-R08F06-06X014PV05,0-ES-103556
C-R08F06-06X014PV10,0-ES-103557
C-R08F06-06X014PV15,0-ES-103558
C-R08F06-06X014PV20,0-ES-103559
C-R08F06-06X014PV25,0-ES-103560
CEM-A-BE05
CEM-A-BH10
CEM-A-LE05H-S2
CEM-A-LE05K-S2
CEM-A-LE05R-S2
CEM-A-LH10K-S3
CEM-A-LH10R-S3
CEM-A-ZPS-110013
CES-A-BBA
102218
103782
099633
100456
099634
105071
103115
113188
113189
100177
077751
100178
077752
077753
100179
077871
077872
077873
103556
103557
103558
103559
103560
094805
095175
104606
094800
095792
095170
095793
110013
071840
CES-A-BBN-106600
CES-A-BBN-C04-115271
CES-A-BCA
106600
115271
088786
CES-A-BDA-20
CES-A-BDN-06-104730
084720
104730
CES-A-BLN-L2-104510
CES-A-BLN-R2-100776
CES-A-BLN-U2-103450
CES-A-BMB
CES-A-BPA
104510
100776
103450
077791
098775
CES-A-BQA
CES-A-BRN-100251
098108
100251
CES-A-BSP-104970
CES-A-C5E-01
CES-A-C5H-01
104970
077750
091458
Page
82, 157,
206
157, 206
82, 157,
206
157, 206
82, 157,
206
68
68
68
68
68
68
68
157, 206
157, 206
157, 206
103
157, 206
103
103
157, 206
103
103
103
157
157
157
157
157
52
53
48
46
46
50
50
48
33, 101,
117, 133,
185
31
146
33, 101,
117, 133,
185
35
32, 147,
193
140, 192
140, 192
140, 192
36, 86
102, 118,
134, 186
34
119, 135,
187
30
98
98
237
Item Index
Item
CES-A-LCA-10V
CES-A-LMN-SC
CES-A-LNA-05P
CES-A-LNA-05V
CES-A-LNA-10P
CES-A-LNA-10V
CES-A-LNA-15P
CES-A-LNA-15V
CES-A-LNA-25V
CES-A-LNA-SC
CES-A-LNN-05V-106602
CES-A-LNN-10V-113294
CES-A-LNN-25V-115107
CES-A-LNN-SC-106601
CES-A-LQA-SC
CES-A-LSP-05V-104966
CES-A-LSP-10V-104967
CES-A-LSP-SB-104969
CES-A-W5H-01
CES-AH-C03-AH-SM-106300
CES-AP-C01-AH-SB-111145
CES-AP-C01-CH-SA-100250
CES-AP-C01-CH-SB-106798
CES-AP-C01-CH-SB-111708
CES-AP-CL2-AH-L05-105603
CES-AP-CL2-AH-L10-106192
CES-AP-CL2-AH-L20-106196
CES-AP-CL2-AH-SB-106553
CES-AP-CL2-AH-SB-111747
CES-AP-CL2-AH-SF-105294
CES-AP-CL2-CH-L05-105602
CES-AP-CL2-CH-L10-106190
CES-AP-CL2-CH-L20-106194
CES-AP-CL2-CH-SB-106551
CES-AP-CL2-CH-SB-109167
CES-AP-CL2-CH-SF-104509
CES-AP-CR2-AH-L05-105601
CES-AP-CR2-AH-L10-106191
CES-AP-CR2-AH-L20-106195
CES-AP-CR2-AH-SB-106552
CES-AP-CR2-AH-SB-111748
CES-AP-CR2-AH-SF-105295
CES-AP-CR2-CH-L05-105600
CES-AP-CR2-CH-L10-106189
CES-AP-CR2-CH-L20-106193
CES-AP-CR2-CH-SB-106550
CES-AP-CR2-CH-SB-109168
CES-AP-CR2-CH-SF-100775
CES-AR-AES-12
CES-AR-C01-AH-SA
CES-AR-C01-CH-SA
CES-AR-C01-EH-SA
CES-AR-CL2-AH-L05-109047
CES-AR-CL2-AH-L10-109051
CES-AR-CL2-AH-L20-109055
CES-AR-CL2-AH-SA-105748
CES-AR-CL2-AH-SG-105753
CES-AR-CL2-CH-L05-109045
CES-AR-CL2-CH-L10-109049
CES-AR-CL2-CH-L20-109053
CES-AR-CL2-CH-SA-105747
CES-AR-CL2-CH-SA-112929
CES-AR-CL2-CH-SA-115793
238
Order no.
088785
077790
077806
071845
077807
071846
084682
071847
071975
077715
106602
113294
115107
106601
095650
104966
104967
104969
097525
106300
111145
100250
106798
111708
105603
106192
106196
106553
111747
105294
105602
106190
106194
106551
109167
104509
105601
106191
106195
106552
111748
105295
105600
106189
106193
106550
109168
100775
098225
098941
098942
098582
109047
109051
109055
105748
105753
109045
109049
109053
105747
112929
115793
Page
24
28, 84
24
24
24
24
24
24
24
24
22
22
22
22
26
20
20
20
98
114
130
130
130
130
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
221
182
182
182
191
191
191
191
191
191
191
191
191
191
191
Item
CES-AR-CL2-CH-SG-105752
CES-AR-CR2-AH-L05-109046
CES-AR-CR2-AH-L10-109050
CES-AR-CR2-AH-L20-109054
CES-AR-CR2-AH-SA-105746
CES-AR-CR2-AH-SG-105751
CES-AR-CR2-CH-L05-109044
CES-AR-CR2-CH-L10-109048
CES-AR-CR2-CH-L20-109052
CES-AR-CR2-CH-SA-105745
CES-AR-CR2-CH-SA-112928
CES-AR-CR2-CH-SA-115792
CES-AR-CR2-CH-SG-105750
CES-AZ-AES-01B
CES-AZ-AES-02B
CES-AZ-AES-04B
CES-AZ-ALS-04B
CES-AZ-UES-01B
CES-AZ-UES-02B
CES-AZ-UES-04B
CES-EA-TC-AK04-104756
CES-EA-TC-AK06-104771
CES-EA-TC-AK08-104776
Order no.
105752
109046
109050
109054
105746
105751
109044
109048
109052
105745
112928
115792
105750
104770
104775
104780
113090
105139
105140
105141
104756
104771
104776
CES-EA-TC-KK04-112631
CES-EA-TC-KK06-112630
CES-EA-TC-KK08-112629
112631
112630
112629
CES-FD-AP-M-01-USI-115534
CES-FD-AP-U-01-USI-119865
CES-I-AP-M-C04-SK-117325
CES-I-AP-M-C04-U05-117328
CES-I-AP-M-C04-U10-117329
CES-I-AP-M-C04-U20-117330
CES-I-AP-M-C04-USB-117324
CES-I-AP-M-C04-USI-117323
CES-I-AP-U-C04-SK-115324
CES-I-AP-U-C04-U05-116503
CES-I-AP-U-C04-U10-116504
CES-I-AP-U-C04-U20-116505
CES-I-AP-U-C04-USB-116502
CES-I-AP-U-C04-USI-115150
CET cover, left
115534
119865
117325
117328
117329
117330
117324
117323
115324
116503
116504
116505
116502
115150
098807
098808
CET-A-BWK-50X
096327
CET1-AR-CDA-AH-50X-SG-106275
CET1-AR-CDA-CH-50X-SG-109231
CET1-AR-CRA-AH-50A-SG-106616
CET1-AR-CRA-AH-50F-SG-106159
CET1-AR-CRA-AH-50F-SG-C2333-111766
CET1-AR-CRA-AH-50F-SH-C2312-110943
CET1-AR-CRA-AH-50F-SH-C2353-113021
CET1-AR-CRA-AH-50S-SG-105802
CET1-AR-CRA-AH-50S-SG-C2290-113320
CET1-AR-CRA-AH-50X-SG-103418
CET1-AR-CRA-AH-50X-SG-C2333-112121
CET1-AR-CRA-AH-50X-SH-110203
CET1-AR-CRA-AH-50X-SH-C2290-113022
CET1-AR-CRA-CH-50F-SG-110241
106275
109231
106616
106159
111766
110943
113021
105802
113320
103418
112121
110203
113022
110241
Page
191
191
191
191
191
191
191
191
191
191
191
191
191
14
16
18
18
14
16
18
14, 70
16, 70
18, 70,
221
14, 70
16, 70
18, 70,
221
82
82
145
145
145
145
145
145
145
145
145
145
145
145
74, 168,
217
74, 168,
217
62, 169,
218, 235,
236
200
200
200
200
200
203
203
200
200
200
200
203
203
200
Item Index
Order no.
Item
CET1-AR-CRA-CH-50F-SG-C2333-113272
CET1-AR-CRA-CH-50S-SG-105764
CET1-AR-CRA-CH-50X-SG-105763
CET1-AR-CRA-CH-50X-SG-C2290-109015
CET1-AR-CRA-CH-50X-SH-110204
CET1-AR-CRA-CH-50X-SH-113255
CET1-AX-LDA-00-50F-SA
CET1-AX-LDA-00-50X-SC
CET1-AX-LDA-00-50X-SE
CET1-AX-LRA-00-50F-SA
CET1-AX-LRA-00-50F-SA-C2333-111918
CET1-AX-LRA-00-50L-SA
CET1-AX-LRA-00-50X-SA
CET1-AX-LRA-00-50X-SA-C2333-111917
CET1-AX-LRA-00-50X-SC
CET1-AX-LRA-00-50X-SF
CET2-AR-CDA-AH-50X-SH-112466
CET2-AR-CRA-AH-50S-SG-109075
CET2-AR-CRA-AH-50X-SG-110240
CET2-AR-CRA-AH-50X-SH-110205
CET2-AR-CRA-CH-50F-SG-C2312-109941
CET2-AR-CRA-CH-50X-SG-110082
CET2-AR-CRA-CH-50X-SH-110206
CET2-AX-LRA-00-50X-SA
CET2-AX-LRA-00-50X-SC
CET3-AP-CRA-AH-50F-SH-C2312-119106
CET3-AP-CRA-AH-50F-SI-114073
CET3-AP-CRA-AH-50F-SI-C2333-114516
CET3-AP-CRA-AH-50F-SI-C2357-114626
CET3-AP-CRA-AH-50X-SI-111346
CET3-AP-CRA-AH-50X-SI-C2333-114223
CET3-AR-CDA-AH-50F-SH-114647
CET3-AR-CDA-CH-50F-SG-114090
CET3-AR-CRA-AH-50F-SG-113965
CET3-AR-CRA-AH-50F-SG-C2333-114508
CET3-AR-CRA-AH-50F-SH-113148
CET3-AR-CRA-AH-50F-SH-C2312-111725
CET3-AR-CRA-AH-50F-SH-C2333-114505
CET3-AR-CRA-AH-50F-SH-C2353-113023
CET3-AR-CRA-AH-50X-SG-109401
CET3-AR-CRA-AH-50X-SG-C2290-113139
CET3-AR-CRA-AH-50X-SG-C2333-114512
CET3-AR-CRA-AH-50X-SH-110103
CET3-AR-CRA-AH-50X-SH-C2290-113024
CET3-AR-CRA-AH-50X-SH-C2290-114088
CET3-AR-CRA-AH-50X-SH-C2333-113151
CET3-AR-CRA-CH-50F-SG-110907
CET3-AR-CRA-CH-50F-SG-C2290-110905
CET3-AR-CRA-CH-50F-SG-C2333-112921
CET3-AR-CRA-CH-50F-SG-C2357-113958
CET3-AR-CRA-CH-50S-SG-112992
CET3-AR-CRA-CH-50X-SG-110906
CET3-AR-CRA-CH-50X-SG-C2290-110114
CET3-AR-CRA-CH-50X-SH-110104
CET4-AP-CRA-AH-50X-SI-112082
CET4-AR-CDA-CH-50X-SG-114712
CET4-AR-CRA-AH-50F-SH-116285
CET4-AR-CRA-AH-50X-SG-111683
CET4-AR-CRA-AH-50X-SH-110201
CET4-AR-CRA-CH-50F-SG-114650
CET4-AR-CRA-CH-50S-SG-113081
CET4-AR-CRA-CH-50X-SG-111684
CET4-AR-CRA-CH-50X-SG-C2333-113767
113272
105764
105763
109015
110204
113255
103750
103444
100399
102161
111918
104062
095735
111917
102988
104051
112466
109075
110240
110205
109941
110082
110206
106039
109932
119106
114073
114516
114626
111346
114223
114647
114090
113965
114508
113148
111725
114505
113023
109401
113139
114512
110103
113024
114088
113151
110907
110905
112921
113958
112992
110906
110114
110104
112082
114712
116285
111683
110201
114650
113081
111684
113767
Page
200
200
200
200
203
203
61
62
61
61
61
61
61
61
62
61
203
200
200
203
200
200
203
61
62
153
152
152
152
152
152
203
201
201
201
203
203
203
203
201
201
201
203
203
203
203
201
201
201
201
201
201
201
203
152
201
203
201
203
201
201
201
201
Order no.
Item
CET4-AR-CRA-CH-50X-SG-C2355-113609
CET4-AR-CRA-CH-50X-SH-110202
CKS-A-BK1-RD-113461
CKS-A-L1B-SC-113130
Double ramp for CET
113609
110202
113461
113130
114091
103714
EMP-B-CEM05
EMP-B-CET
100110
106694
EMP-L-CEM05
EMP-L-CET
099425
106695
115464
099795
Insertion tool
Installation material, 10-slot, Bosch
Installation material, 8-slot, Bosch
Installation material, 8-slot, ITEM
KD4C1851
Lead seal kit for emergency unlocking
037662
106634
106633
106635
077434
087256
098850
098850
106597
094309
096945
074616
092761
092883
092898
092887
077016
092888
092726
092889
092727
092890
095993
109681
092816
092884
077014
092885
077015
092886
074617
092906
092891
092907
092892
092901
092699
092902
092700
077020
092701
085196
092702
092910
Page
201
203
40, 87
40, 87
74, 168,
217
73, 167,
216
54
71, 165,
214
54
71, 165,
214
82
62, 167,
218
36, 86
20, 30, 72
20, 30, 72
20, 30, 72
70
73, 167,
216
73
167, 216
120
162, 211
75
162, 211
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
162, 211
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
239
Item Index
Order no.
Item
RC18WF20MLF-C1825
RC18WF20MR-C1825
RC18WF20MRF-C1825
RC18WF25ML-C1825
RC18WF25MLF-C1825
RC18WF25MR-C1825
RC18WF25MRF-C1825
RC18WF3ML-C1825
RC18WF3MLF-C1825
RC18WF3MR-C1825
RC18WF3MRF-C1825
RC18WF6ML-C1825
RC18WF6MLF-C1825
RC18WF6MR-C1825
RC18WF6MRF-C1825
RC18WF8ML-C1825
RC18WF8MLF-C1825
RC18WF8MR-C1825
RC18WF8MRF-C1825
Replacement key
092704
092911
092708
092912
092724
092913
092725
092908
092893
092909
092894
077018
092697
085194
092698
077019
092895
085195
092896
099434
086232
071863
Safety screws M4 x 20
Safety screws M5 x 10
116978
073455
Safety screws M5 x 16
073456
Y-distributor M12
Y-distributor with connection cable
Y-distributor with connection cable
097627
111696
112395
240
Page
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
73, 167,
216
89, 166,
215
72, 104,
121, 166,
215
166
104, 121,
166, 215
62, 72,
121, 166,
215
212
212
212
Order no.
Item
Page
Item Index
Index by order numbers
Order no.
037662
071840
Item
Insertion tool
CES-A-BBA
071845
071846
071847
071863
CES-A-LNA-05V
CES-A-LNA-10V
CES-A-LNA-15V
Safety screws M4 x 14 (small head)
071975
073455
CES-A-LNA-25V
Safety screws M5 x 10
073456
Safety screws M5 x 16
074616
074617
076487
077014
077015
077016
077018
077019
077020
077434
077435
077715
077716
077717
077750
077751
077752
077753
077767
077790
077791
077793
077806
077807
077871
077872
077873
077935
082220
084682
084701
084703
084705
084720
084762
084763
084764
084765
084766
085194
085195
085196
086173
086232
RC18EF
RC18WF
Bolt CES-A-A
RC18EF6M-C1825
RC18EF8M-C1825
RC18EF15M-C1825
RC18WF6ML-C1825
RC18WF8ML-C1825
RC18WF15ML-C1825
KD4C1851
BS4C1851
CES-A-LNA-SC
C-M08F03-02X025PV20,0-ES-077716
C-M08F03-02X025PV25,0-ES-077717
CES-A-C5E-01
C-M12F08-08X025PV05,0-MW-077751
C-M12F08-08X025PV10,0-MW-077752
C-M12F08-08X025PV15,0-MW-077753
C-M08F03-02X025PV10,0-ES-077767
CES-A-LMN-SC
CES-A-BMB
C-M08F03-02X025PV05,0-ES-077793
CES-A-LNA-05P
CES-A-LNA-10P
C-M12F08-08X025PV20,0-MW-077871
C-M12F08-08X025PV25,0-MW-077872
C-M12F08-08X025PV50,0-MW-077873
C-M08F03-02X025PV03,0-ES-077935
Bolt CES-A-C
CES-A-LNA-15P
C-M08F03-02X025PV10,0-ES-084701
C-M08F04-04X025PV10,0-ES-084703
C-M08M04-04X025PV10,0-ES-084705
CES-A-BDA-20
C-M08F03-02X025PU05,0-ES-084762
C-M08F03-02X025PU10,0-ES-084763
C-M08F03-02X025PU15,0-ES-084764
C-M08F03-02X025PU20,0-ES-084765
C-M08F03-02X025PU25,0-ES-084766
RC18WF6MR-C1825
RC18WF8MR-C1825
RC18WF15MR-C1825
Bolt CES-A-A/F
Safety screws M4 x 14 (large head)
Page
36, 86
33, 101,
117, 133,
185
24
24
24
72, 104,
121, 166,
215
24
104, 121,
166, 215
62, 72,
121, 166,
215
162, 211
162, 211
226
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
70
70
24
65
65
98
103
103
103
65
28, 84
36, 86
65
24
24
103
103
103
65
229
24
65
66, 157
67
35
65
65
65
65
65
160, 209
160, 209
160, 209
227
89, 166,
215
Order no.
087256
Item
Lead seal kit for emergency unlocking
088785
088786
CES-A-LCA-10V
CES-A-BCA
088813
088814
088815
088841
088842
088843
088844
091458
092697
092698
092699
092700
092701
092702
092704
092708
092724
092725
092726
092727
092761
092816
092883
092884
092885
092886
092887
092888
092889
092890
092891
092892
092893
092894
092895
092896
092898
092901
092902
092906
092907
092908
092909
092910
092911
092912
092913
094309
094800
094805
095035
095170
095175
095650
095735
C-M08F04-04X025PV05,0-ES-088813
C-M08F04-04X025PV10,0-ES-088814
C-M08F04-04X025PV15,0-ES-088815
C-M08M04-04X025PV02,0-ES-088841
C-M08M04-04X025PV05,0-ES-088842
C-M08M04-04X025PV10,0-ES-088843
C-M08M04-04X025PV15,0-ES-088844
CES-A-C5H-01
RC18WF6MLF-C1825
RC18WF6MRF-C1825
RC18WF10MLF-C1825
RC18WF10MRF-C1825
RC18WF15MLF-C1825
RC18WF15MRF-C1825
RC18WF20MLF-C1825
RC18WF20MRF-C1825
RC18WF25MLF-C1825
RC18WF25MRF-C1825
RC18EF20M-C1825
RC18EF25M-C1825
RC18EF1,5M-C1825
RC18EF3M-C1825
RC18EF1,5MF-C1825
RC18EF3MF-C1825
RC18EF6MF-C1825
RC18EF8MF-C1825
RC18EF10MF-C1825
RC18EF15MF-C1825
RC18EF20MF-C1825
RC18EF25MF-C1825
RC18WF1,5MLF-C1825
RC18WF1,5MRF-C1825
RC18WF3MLF-C1825
RC18WF3MRF-C1825
RC18WF8MLF-C1825
RC18WF8MRF-C1825
RC18EF10M-C1825
RC18WF10ML-C1825
RC18WF10MR-C1825
RC18WF1,5ML-C1825
RC18WF1,5MR-C1825
RC18WF3ML-C1825
RC18WF3MR-C1825
RC18WF20ML-C1825
RC18WF20MR-C1825
RC18WF25ML-C1825
RC18WF25MR-C1825
Pin crimp contact RCM
CEM-A-LE05K-S2
CEM-A-BE05
C-M08F04-04X025PV25,0-ES-095035
CEM-A-LH10K-S3
CEM-A-BH10
CES-A-LQA-SC
CET1-AX-LRA-00-50X-SA
Page
73, 167,
216
24
33, 101,
117, 133,
185
66, 157
66, 157
66, 157
67
67
67
67
98
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
160, 209
162, 211
46
52
66, 157
50
53
26
61
241
Item Index
Order no.
095792
095793
095993
096327
096945
097525
097627
097645
097955
097957
098108
098225
098357
098582
098590
098775
098807
098808
098850
098850
098941
098942
099425
099434
099633
099634
099795
099998
100110
100177
100178
100179
100180
100181
100182
100183
100184
100185
100250
100251
100399
100456
100775
100776
102161
102218
102988
103115
103418
103444
103450
103556
242
Item
CEM-A-LE05R-S2
CEM-A-LH10R-S3
RC18EF30M-C1825
CET-A-BWK-50X
Page
46
50
160, 209
62, 169,
218, 235,
236
PM-SCL-096945
75
CES-A-W5H-01
98
Y-distributor M12
212
Bridging plug
212
Bolt CEM-A
228
Bolt CEM-C
228
CES-A-BQA
34
CES-AR-AES-12
221
Bolt CES-A-C/F
230
CES-AR-C01-EH-SA
182
C-M08F03-02X025PU10,0-ES-098590
65
CES-A-BPA
102, 118,
134, 186
CET cover, left
74, 168,
217
CET cover, right
74, 168,
217
Mechanical key release
73
Mechanical key release
167, 216
CES-AR-C01-AH-SA
182
CES-AR-C01-CH-SA
182
EMP-L-CEM05
54
Replacement key
73, 167,
216
C-M12F08-07X025PV10,0-MA-099633
68
C-M12F08-07X025PV20,0-MA-099634
68
Handle for wire front release
62, 167,
218
C-M08F03-02X025PV25,0-ES-099998
65
EMP-B-CEM05
54
C-M12F08-08X025PV05,0-MA-100177
157, 206
C-M12F08-08X025PV10,0-MA-100178
157, 206
C-M12F08-08X025PV20,0-MA-100179
157, 206
C-M12F05-05X034PV05,0-M12M05-100180 157, 206
C-M12F05-05X034PV10,0-M12M05-100181 157, 206
C-M12F05-05X034PV20,0-M12M05-100182 157, 206
C-M12F05-05X034PV05,0-MA-100183
82, 157,
206
C-M12F05-05X034PV10,0-MA-100184
82, 157,
206
C-M12F05-05X034PV20,0-MA-100185
82, 157,
206
CES-AP-C01-CH-SA-100250
130
CES-A-BRN-100251
119, 135,
187
CET1-AX-LDA-00-50X-SE
61
C-M12F08-07X025PV10,0-MA-100456
68
CES-AP-CR2-CH-SF-100775
139
CES-A-BLN-R2-100776
140, 192
CET1-AX-LRA-00-50F-SA
61
C-M12F08-07X025PU10,0-MA-102218
68
CET1-AX-LRA-00-50X-SC
62
C-M12F08-07X025PV25,0-MA-103115
68
CET1-AR-CRA-AH-50X-SG-103418
200
CET1-AX-LDA-00-50X-SC
62
CES-A-BLN-U2-103450
140, 192
C-R08F06-06X014PV05,0-ES-103556
157
Order no.
103557
103558
103559
103560
103714
Item
C-R08F06-06X014PV10,0-ES-103557
C-R08F06-06X014PV15,0-ES-103558
C-R08F06-06X014PV20,0-ES-103559
C-R08F06-06X014PV25,0-ES-103560
Emergency unlocking CET
103750
103782
104028
104051
104062
104309
104509
104510
104606
104730
CET1-AX-LDA-00-50F-SA
C-M12F08-07X025PU25,0-MA-103782
Bolt CES-ACR1-AR-C01-AH-SA-104028
CET1-AX-LRA-00-50X-SF
CET1-AX-LRA-00-50L-SA
Bolt CET-A-C
CES-AP-CL2-CH-SF-104509
CES-A-BLN-L2-104510
CEM-A-LE05H-S2
CES-A-BDN-06-104730
104756
104770
104771
104775
104776
CES-EA-TC-AK04-104756
CES-AZ-AES-01B
CES-EA-TC-AK06-104771
CES-AZ-AES-02B
CES-EA-TC-AK08-104776
104780
104966
104967
104969
104970
105071
105139
105140
105141
105294
105295
105555
105556
105559
105600
105601
105602
105603
105619
105745
105746
105747
105748
105750
105751
105752
105753
105763
105764
105802
106039
106159
106172
106189
106190
106191
106192
106193
106194
106195
CES-AZ-AES-04B
CES-A-LSP-05V-104966
CES-A-LSP-10V-104967
CES-A-LSP-SB-104969
CES-A-BSP-104970
C-M12F08-07X025PV20,0-MA-105071
CES-AZ-UES-01B
CES-AZ-UES-02B
CES-AZ-UES-04B
CES-AP-CL2-AH-SF-105294
CES-AP-CR2-AH-SF-105295
C-M05F03-02X014PV05,0-ES-105555
C-M05F03-02X014PV10,0-ES-105556
C-M05F03-02X014PV20,0-ES-105559
CES-AP-CR2-CH-L05-105600
CES-AP-CR2-AH-L05-105601
CES-AP-CL2-CH-L05-105602
CES-AP-CL2-AH-L05-105603
Bolt CES-AC/F-AR-C01-AH-SA-105619
CES-AR-CR2-CH-SA-105745
CES-AR-CR2-AH-SA-105746
CES-AR-CL2-CH-SA-105747
CES-AR-CL2-AH-SA-105748
CES-AR-CR2-CH-SG-105750
CES-AR-CR2-AH-SG-105751
CES-AR-CL2-CH-SG-105752
CES-AR-CL2-AH-SG-105753
CET1-AR-CRA-CH-50X-SG-105763
CET1-AR-CRA-CH-50S-SG-105764
CET1-AR-CRA-AH-50S-SG-105802
CET2-AX-LRA-00-50X-SA
CET1-AR-CRA-AH-50F-SG-106159
Bolt CET-A-C/F
CES-AP-CR2-CH-L10-106189
CES-AP-CL2-CH-L10-106190
CES-AP-CR2-AH-L10-106191
CES-AP-CL2-AH-L10-106192
CES-AP-CR2-CH-L20-106193
CES-AP-CL2-CH-L20-106194
CES-AP-CR2-AH-L20-106195
Page
157
157
157
157
73, 167,
216
61
68
232
61
61
235
139
140, 192
48
32, 147,
193
14, 70
14
16, 70
16
18, 70,
221
18
20
20
20
30
68
14
16
18
139
139
64
64
64
139
139
139
139
233
191
191
191
191
191
191
191
191
200
200
200
61
200
235
139
139
139
139
139
139
139
Item Index
Order no.
106196
106275
106300
106550
106551
106552
106553
106597
106600
106601
106602
106616
106633
106634
106635
106671
106672
106673
106694
Item
CES-AP-CL2-AH-L20-106196
CET1-AR-CDA-AH-50X-SG-106275
CES-AH-C03-AH-SM-106300
CES-AP-CR2-CH-SB-106550
CES-AP-CL2-CH-SB-106551
CES-AP-CR2-AH-SB-106552
CES-AP-CL2-AH-SB-106553
P-M23F09-106597
CES-A-BBN-106600
CES-A-LNN-SC-106601
CES-A-LNN-05V-106602
CET1-AR-CRA-AH-50A-SG-106616
Installation material, 8-slot, Bosch
Installation material, 10-slot, Bosch
Installation material, 8-slot, ITEM
C-M08F08-08X014PU05,0-ES-106671
C-M08F08-08X014PU10,0-ES-106671
C-M08F08-08X014PU20,0-ES-106673
EMP-B-CET
106695
EMP-L-CET
106798
109015
109044
109045
109046
109047
109048
109049
109050
109051
109052
109053
109054
109055
109075
109167
109168
109231
109358
109401
109672
109681
109932
109941
110013
110082
110103
110104
110114
110201
110202
110203
110204
110205
110206
110240
110241
110354
110355
110905
110906
CES-AP-C01-CH-SB-106798
CET1-AR-CRA-CH-50X-SG-C2290-109015
CES-AR-CR2-CH-L05-109044
CES-AR-CL2-CH-L05-109045
CES-AR-CR2-AH-L05-109046
CES-AR-CL2-AH-L05-109047
CES-AR-CR2-CH-L10-109048
CES-AR-CL2-CH-L10-109049
CES-AR-CR2-AH-L10-109050
CES-AR-CL2-AH-L10-109051
CES-AR-CR2-CH-L20-109052
CES-AR-CL2-CH-L20-109053
CES-AR-CR2-AH-L20-109054
CES-AR-CL2-AH-L20-109055
CET2-AR-CRA-AH-50S-SG-109075
CES-AP-CL2-CH-SB-109167
CES-AP-CR2-CH-SB-109168
CET1-AR-CDA-CH-50X-SG-109231
Bolt CES-AC-AR-C01-AH-SA-C2296
CET3-AR-CRA-AH-50X-SG-109401
Bolt CET-A-C-C2308
RC18EF30MF-C1825
CET2-AX-LRA-00-50X-SC
CET2-AR-CRA-CH-50F-SG-C2312-109941
CEM-A-ZPS-110013
CET2-AR-CRA-CH-50X-SG-110082
CET3-AR-CRA-AH-50X-SH-110103
CET3-AR-CRA-CH-50X-SH-110104
CET3-AR-CRA-CH-50X-SG-C2290-110114
CET4-AR-CRA-AH-50X-SH-110201
CET4-AR-CRA-CH-50X-SH-110202
CET1-AR-CRA-AH-50X-SH-110203
CET1-AR-CRA-CH-50X-SH-110204
CET2-AR-CRA-AH-50X-SH-110205
CET2-AR-CRA-CH-50X-SH-110206
CET2-AR-CRA-AH-50X-SG-110240
CET1-AR-CRA-CH-50F-SG-110241
Bolt CES-AC-AP-C01-CH-SB-110354
Bolt CES-AC-AP-C01-CH-SB-110355
CET3-AR-CRA-CH-50F-SG-C2290-110905
CET3-AR-CRA-CH-50X-SG-110906
Page
139
200
114
139
139
139
139
120
31
22
22
200
20, 30, 72
20, 30, 72
20, 30, 72
206
206
206
71, 165,
214
71, 165,
214
130
200
191
191
191
191
191
191
191
191
191
191
191
191
200
139
139
200
231
201
236
160, 209
62
200
48
200
203
203
201
203
203
203
203
203
203
200
200
234
234
201
201
Order no.
110907
110933
110934
110935
110943
111145
111346
111603
111683
111684
111696
111708
111725
111747
111748
111766
111917
111918
112082
112121
112395
112466
112629
Item
CET3-AR-CRA-CH-50F-SG-110907
C-M08F08-08X014PV05,0-ES-110933
C-M08F08-08X014PV10,0-ES-110934
C-M08F08-08X014PV15,0-ES-110935
CET1-AR-CRA-AH-50F-SH-C2312-110943
CES-AP-C01-AH-SB-111145
CET3-AP-CRA-AH-50X-SI-111346
C-M08F08-08X014PV20,0-ES-111603
CET4-AR-CRA-AH-50X-SG-111683
CET4-AR-CRA-CH-50X-SG-111684
Y-distributor with connection cable
CES-AP-C01-CH-SB-111708
CET3-AR-CRA-AH-50F-SH-C2312-111725
CES-AP-CL2-AH-SB-111747
CES-AP-CR2-AH-SB-111748
CET1-AR-CRA-AH-50F-SG-C2333-111766
CET1-AX-LRA-00-50X-SA-C2333-111917
CET1-AX-LRA-00-50F-SA-C2333-111918
CET4-AP-CRA-AH-50X-SI-112082
CET1-AR-CRA-AH-50X-SG-C2333-112121
Y-distributor with connection cable
CET2-AR-CDA-AH-50X-SH-112466
CES-EA-TC-KK08-112629
112630
112631
112921
112928
112929
112992
113021
113022
113023
113024
113081
113090
113130
113139
113148
113151
113187
113188
113189
113190
113255
113272
113294
113320
113461
113609
113767
113958
113965
113986
114073
114088
114090
114091
CES-EA-TC-KK06-112630
CES-EA-TC-KK04-112631
CET3-AR-CRA-CH-50F-SG-C2333-112921
CES-AR-CR2-CH-SA-112928
CES-AR-CL2-CH-SA-112929
CET3-AR-CRA-CH-50S-SG-112992
CET1-AR-CRA-AH-50F-SH-C2353-113021
CET1-AR-CRA-AH-50X-SH-C2290-113022
CET3-AR-CRA-AH-50F-SH-C2353-113023
CET3-AR-CRA-AH-50X-SH-C2290-113024
CET4-AR-CRA-CH-50S-SG-113081
CES-AZ-ALS-04B
CKS-A-L1B-SC-113130
CET3-AR-CRA-AH-50X-SG-C2290-113139
CET3-AR-CRA-AH-50F-SH-113148
CET3-AR-CRA-AH-50X-SH-C2333-113151
C-M12F05-05X025P10,0-MA-113187
C-M12F08-08X025PU10.0-MA-113188
C-M12F08-08X025PU10.0-MA-113189
C-M12F05-05X025P10,0-MA-113190
CET1-AR-CRA-CH-50X-SH-113255
CET1-AR-CRA-CH-50F-SG-C2333-113272
CES-A-LNN-10V-113294
CET1-AR-CRA-AH-50S-SG-C2290-113320
CKS-A-BK1-RD-113461
CET4-AR-CRA-CH-50X-SG-C2355-113609
CET4-AR-CRA-CH-50X-SG-C2333-113767
CET3-AR-CRA-CH-50F-SG-C2357-113958
CET3-AR-CRA-AH-50F-SG-113965
Bolt CES-AC-AP-C01-AH-SB-C2296
CET3-AP-CRA-AH-50F-SI-114073
CET3-AR-CRA-AH-50X-SH-C2290-114088
CET3-AR-CDA-CH-50F-SG-114090
Double ramp for CET
114223
114505
114508
114512
CET3-AP-CRA-AH-50X-SI-C2333-114223
CET3-AR-CRA-AH-50F-SH-C2333-114505
CET3-AR-CRA-AH-50F-SG-C2333-114508
CET3-AR-CRA-AH-50X-SG-C2333-114512
Page
201
206
206
206
203
130
152
206
201
201
212
130
203
139
139
200
61
61
152
200
212
203
18, 70,
221
16, 70
14, 70
201
191
191
201
203
203
203
203
201
18
40, 87
201
203
203
157, 206
157, 206
157, 206
157, 206
203
200
22
200
40, 87
201
201
201
201
231
152
203
201
74, 168,
217
152
203
201
201
243
Item Index
Order no.
114516
114626
114647
114650
114712
115107
115150
115271
115324
115464
115534
115565
115566
115732
115792
115793
116049
116050
116051
116246
116285
116502
116503
116504
116505
116978
117323
117324
117325
117328
117329
117330
119106
119690
119694
119865
244
Item
CET3-AP-CRA-AH-50F-SI-C2333-114516
CET3-AP-CRA-AH-50F-SI-C2357-114626
CET3-AR-CDA-AH-50F-SH-114647
CET4-AR-CRA-CH-50F-SG-114650
CET4-AR-CDA-CH-50X-SG-114712
CES-A-LNN-25V-115107
CES-I-AP-U-C04-USI-115150
CES-A-BBN-C04-115271
CES-I-AP-U-C04-SK-115324
Extension for read head cable
with M8 plug connector, 3-core 0.4 m, PUR
CES-FD-AP-M-01-USI-115534
C-M12F05-05X025P10,0-M12M05-115565
C-M12F05-05X025P10,0-M12M05-115566
Bolt CES-AC/F-AP-C01-CH-SB-115732
CES-AR-CR2-CH-SA-115792
CES-AR-CL2-CH-SA-115793
C-M08F04-04X034PU05,0-ES-116049
C-M08F04-04X034PU10,0-ES-116050
C-M08F04-04X034PU20,0-ES-116051
Bolt CES-AC/F-AP-C01-AH-SB-116246
CET4-AR-CRA-AH-50F-SH-116285
CES-I-AP-U-C04-USB-116502
CES-I-AP-U-C04-U05-116503
CES-I-AP-U-C04-U10-116504
CES-I-AP-U-C04-U20-116505
Safety screws M4 x 20
CES-I-AP-M-C04-USI-117323
CES-I-AP-M-C04-USB-117324
CES-I-AP-M-C04-SK-117325
CES-I-AP-M-C04-U05-117328
CES-I-AP-M-C04-U10-117329
CES-I-AP-M-C04-U20-117330
CET3-AP-CRA-AH-50F-SH-C2312-119106
AM-SET-PP-119690
AM-SET-PPB-119694
CES-FD-AP-U-01-USI-119865
Page
152
152
203
201
201
22
145
146
145
82
82
157, 206
157, 206
233
191
191
66, 157
66, 157
66, 157
233
203
145
145
145
145
166
145
145
145
145
145
145
153
163
163
82
Order no.
Item
Page
245
Representatives
International
Australia
Micromax Sensors & Automation
Unit 2, 106-110 Beaconseld Street
Silverwater, NSW 2128
Tel. +61 2 87482800
Fax +61 2 96482345
info@micromaxsa.com.au
Denmark
Duelco A/S
Systemvej 8
9200 Aalborg SV
Tel. +45 7010 1007
Fax +45 7010 1008
info@duelco.dk
Italy
TRITECNICA S.r.l.
Viale Lazio 26
20135 Milano
Tel. +39 02 541941
Fax +39 02 55010474
info@tritecnica.it
Austria
EUCHNER GmbH
Sddruckgasse 4
2512 Tribuswinkel
Tel. +43 2252 42191
Fax +43 2252 45225
info@euchner.at
Finland
Shklehto Oy
Holkkitie 14
00880 Helsinki
Tel. +358 9 7746420
Fax +358 9 7591071
ofce@sahkolehto.
Benelux
EUCHNER (BENELUX) BV
Visschersbuurt 23
3356 AE Papendrecht
Tel. +31 78 615-4766
Fax +31 78 615-4311
info@euchner.nl
France
EUCHNER France S.A.R.L.
Parc dAffaires des Bellevues
Alle Rosa Luxembourg
Btiment le Colorado
95610 ERAGNY sur OISE
Tel. +33 1 3909-9090
Fax +33 1 3909-9099
info@euchner.fr
Japan
EUCHNER
Representative Ofce Japan
8-20-24 Kamitsurumahoncho
Minami-ku, Sagamihara-shi
Kanagawa 252-0318
Tel. +81 42 8127767
Fax +81 42 7642708
hayashi@euchner.jp
Brazil
EUCHNER Ltda
Av. Prof. Luiz Igncio Anhaia Mello,
no. 4387
S. Lucas
So Paulo - SP - Brasil
CEP 03295-000
Tel. +55 11 29182200
Fax +55 11 23010613
euchner@euchner.com.br
Canada
IAC & Associates Inc.
2180 Fasan Drive
Unit A
Oldcastle, Ontario
N0R 1L0
Tel. +1 519 737-0311
Fax +1 519 737-0314
sales@iacnassociates.com
China
EUCHNER (Shanghai)
Trading Co., Ltd.
No. 8 Workshop A, Hi-Tech Zone
503 Meinengda Road Songjiang
201613 Shanghai
Tel. +86 21 5774-7090
Fax +86 21 5774-7599
info@euchner.com.cn
Czech Republic
EUCHNER electric s.r.o.
Vidensk 134/102
61900 Brno
Tel. +420 533 443-150
Fax +420 533 443-153
info@euchner.cz
Hong Kong
Imperial
Engineers & Equipment Co. Ltd.
Unit B 12/F
Cheung Lee Industrial Building
9 Cheung Lee Street Chai Wan
Hong Kong
Tel. +852 2889 0292
Fax +852 2889 1814
info@imperial-elec.com
Hungary
EUCHNER Ges.mbH
Magyarorszgi Fiktelep
2045 Trkblint
FSD Park 2.
Tel. +36 2342 8374
Fax +36 2342 8375
info@euchner.hu
India
EUCHNER (India) Pvt. Ltd.
401, Bremen Business Center,
City Survey No. 2562,
University Road
Aundh, Pune - 411007
Tel. +91 20 64016384
Fax +91 20 25885148
info@euchner.in
Israel
Ilan & Gavish Automation Service Ltd.
26 Shenkar St. Qiryat Arie 49513
P.O. Box 10118
Petach Tikva 49001
Tel. +972 3 9221824
Fax +972 3 9240761
mail@ilan-gavish.com
Romania
First Electric SRL
Str. Ritmului Nr. 1 Bis
Ap. 2, Sector 2
021675 Bucuresti
Tel. +40 21 2526218
Fax +40 21 3113193
ofce@rstelectric.ro
Russia
VALEX electro
Uliza Karjer dom 2, Str. 9, Etash 2
117449 Moskwa
Tel. +7 495 41196-35
Fax +7 495 41196-36
info@valex-electro.ru
Singapore
Sentronics
Automation & Marketing Pte Ltd.
Blk 3, Ang Mo Kio Industrial Park 2A
#05-06
Singapore 568050
Tel. +65 6744 8018
Fax +65 6744 1929
info@sentronics-asia.com
Slovakia
EUCHNER electric s.r.o.
Vidensk 134/102
61900 Brno
Tel. +420 533 443-150
Fax +420 533 443-153
info@euchner.cz
Slovenia
SMM proizvodni sistemi d.o.o.
Jaskova 18
2000 Maribor
Tel. +386 2 4502326
Fax +386 2 4625160
franc.kit@smm.si
Spain
EUCHNER, S.L.
Gurutzegi 12 - Local 1
Polgono Belartza
20018 San Sebastian
Tel. +34 943 316-760
Fax +34 943 316-405
comercial@euchner.es
Switzerland
EUCHNER AG
Falknisstrasse 9a
7320 Sargans
Tel. +41 81 720-4590
Fax +41 81 720-4599
info@euchner.ch
Taiwan
Daybreak Intl (Taiwan) Corp.
3F, No. 124, Chung-Cheng Road
Shihlin 11145, Taipei
Tel. +886 2 8866-1234
Fax +886 2 8866-1239
day111@ms23.hinet.net
Turkey
EUCHNER Endstriyel Emniyet
Teknolojileri Ltd. ti.
Hattat Bahattin Sok.
Ceylan Apt. No. 13/A
Gztepe Mah.
34730 Kadky / Istanbul
Tel. +90 216 359-5656
Fax +90 216 359-5660
info@euchner.com.tr
United Kingdom
EUCHNER (UK) Ltd.
Unit 2 Petre Drive,
Shefeld
South Yorkshire
S4 7PZ
Tel. +44 114 2560123
Fax +44 114 2425333
info@euchner.co.uk
USA
EUCHNER USA Inc.
6723 Lyons Street
East Syracuse, NY 13057
Tel. +1 315 701-0315
Fax +1 315 701-0319
info@euchner-usa.com
EUCHNER USA Inc.
Detroit Ofce
130 Hampton Circle
Rochester Hills, MI 48307
Tel. +1 248 537-1092
Fax +1 248 537-1095
info@euchner-usa.com
Sweden
Censit AB
Box 331
33123 Vrnamo
Tel. +46 370 691010
Fax +46 370 18888
info@censit.se
Germany
Essen/Dortmund
Thomas Kreil
frdern - steuern - regeln
Hackenberghang 8a
45133 Essen
Tel. +49 201 84266-0
Fax +49 201 84266-66
info@kreissl-essen.de
Freiburg
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Steige 5
79206 Breisach
Tel. +49 7664 4038-33
Fax +49 7664 4038-34
peter.seifert@euchner.de
Magdeburg
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Tismarstrae 10
39108 Magdeburg
Tel. +49 391 736279-22
Fax +49 391 736279-23
bernhard.scholz@euchner.de
Nrnberg
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Steiner Strae 22a
90522 Oberasbach
Tel. +49 911 6693829
Fax +49 911 6696722
ralf.paulus@euchner.de
Dsseldorf
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Sundernholz 24
45134 Essen
Tel. +49 201 43083-93
Fax +49 201 43083-94
juergen.eumann@euchner.de
Wiesbaden
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Adolfsallee 3
68185 Wiesbaden
Tel. +49 611 98817644
Fax +49 611 98895071
giancarlo.pasquesi@euchner.de
Hamburg
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Bleickenallee 13
22763 Hamburg
Tel. +49 40 636740-57
Fax +49 40 636740-58
volker.behrens@euchner.de
Mnchen
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Obere Bahnhofstrae 6
82110 Germering
Tel. +49 89 800846-85
Fax +49 89 800846-90
st.kornes@euchner.de
Stuttgart
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Kohlhammerstrae 16
70771 Leinfelden-Echterdingen
Tel. +49 711 7597-0
Fax +49 711 7597-303
oliver.laier@euchner.de
uwe.kupka@euchner.de
10/13
Chemnitz
EUCHNER GmbH + Co. KG
Ingenieur- und Vertriebsbro
Am Vogelherd 2
09627 Bobritzsch-Hilbersdorf
Tel. +49 37325 906000
Fax +49 37325 906004
jens.zehrtner@euchner.de
246
Support hotline
You have technical questions about our products or how they can be used?
For further questions please contact your local sales representative.
Customer-specic solutions
You need a specic solution or have a special requirement?
Please contact us. We can manufacture your custom product even in small quantities.
www.euchner.com
247
076649-18-11/13 Subject to technical modications without notice, no liability will be assumed for any detail. EUCHNER GmbH + Co. KG TA
EN