Sei sulla pagina 1di 1

SPECIFICATIONS

MARK

DESCRIPTION

01

150MM THK CHB WALL IN


SANDPEBBLE FINE AGGREGATE
TEXTURED 100% ACRYLIC-BASED
DIRT PICK-UP RESISTANT FINISH
BY DRYVIT OR APPROVED
EQUIVALENT (COLOR TO
ARCHITECT'S SELECTION;SUBMIT
SAMPLE FOR APPROVAL)

02

6MM THK DARK GRAY


REFLECTIVE GLASS

02a

PLASTERED WALL W/ PAINT


FINISH

03

600MM HIGH CONCRETE BAND

04

SIGNAGE (OWNER SUPPLIED


MATERIAL)

05
WITH HOOD IN OVEN BAKED
FINISH (COLOR TO ARCHITECT'S
SELECTION;SUBMIT SAMPLE FOR
APPROVAL)

ELEVATION AT 'B'

06

1400MM HIGH PARAPET WITH


50X150MM CONCRETE MOULDING
IN SEMI-GLOSS ACRYTEX
TOPCOAT ON SEMI-GLOSS
ACRYTEX PRIMER AND CAST

07

50X150MM ALUMINUM RHS IN


POWDER COATED FINISHED

08

POWDER COATED ALUMINUM


WHITE DOOR/WINDOW (SEE
SCHEDULE OF DOORS &
WINDOW)

09

300X600X20MM THK GRANITE IN


BUSH HAMMERED FINISH (COLOR
TO ARCHITECT'S SELECTION;
SUBMIT SAMPLE FOR APPROVAL)

10

300MM THK CONCRETE LEDGE IN


SEMI-GLOSS ACRYTEX TOPCOAT
ON SEMI-GLOSS ACRYTEX
PRIMER AND CAST

11

CANOPY-01 (SEE CANOPY-01


DETAILS)

12

CANOPY-02 (SEE CANOPY-02


DETAILS)

13

20X10MM GROOVE SPACED @


500MM (SEE BLOW-UP DETAIL)

14

19 MM THK PRE-LAMINATED
BOARD (COLOR TO ARCHITECT'S
SELECTION: SUBMIT SAMPLE
FOR APPROVAL)

15

GREENWALL SYSTEM BY
SPECIALTY CONTRACTOR

16

LIGHTING FIXTURE (SUBMIT


SAMPLE FOR APPROVAL)

17

RAILING (SEE RAILING DETAIL)

18

0.6MM THK PRE-PAINTED


LONGSPAN RIB TYPE
GALVALUME ROOFING

19

100MM THK CHB WALL IN


SEMI-GLOSS PERMACOAT
WALLGUARD TOPCOAT ON
SEMI-GLOSS ACRYTEX PRIMER
AND CAST

20

MODULAR CABINET (REFER TO


OUTPATIENT DEPARTMENT
BLOW-UP DETAILS)

21

100MM HIGH SEMI-RIGID PVC


SKIRTING

22

20X10MM GROOVE

23

HIGH PRESSURE LAMINATE ON


19 MM THK MDF BOARD (WOOD
GRAIN FINISH: TO ARCHITECT'S
SELECTION)

24

ACCENT WALL 2: +25MM


CONCRETE PLASTER IN
SEMI-GLOSS PERMACOAT
TOPCOAT ON ACRYTEX PRIMER
AND CAST

25

100MM THK RC LEDGE

NOTES
ALL FINISHES ARE SUBJECT TO
ARCHITECT'S APPROVAL OR
SELECTION. SUBMIT SAMPLE FOR
APPROVAL.

ELEVATION AT 'A'

REFERENCE FINISH FLOOR LEVEL +0.00M IS +0.50M


OR 50MM HIGHER THAN THE EXISTING LEVEL OF THE
EMERGENCY AREA; VERIFY ACTUAL LEVEL ON SITE.

ARCHITECT:

R.A. 9266, Article IV, Section 33

ENGINEER:

ARCH. ARIAN V. GESULGA


PRC NO.

3027855

VALIDITY : 10/22/2017
TIN :

427-069-918

PTR NO. 7012560

PROJECT TITLE:

ENGR. WOODY M. CABARDO M.ASEP


PRC NO.

DATE :

01/28/2016

VALIDITY :

PLACE :

DAVAO CITY

TIN :

77954

PTR NO.

1028784

DATE :

01/07/2015

427-069-918

PLACE :

DAVAO CITY

PROPOSED FIVE STOREY


HEALTHCARE BUILDING
LOCATION: QUEZON AVE., DIGOS CITY

OWNER:

MEDICAL CENTER OF DIGOS


COOPERATIVE

ALL EXPOSED STRUCTURAL STEEL


AND FRAMES SHALL BE IN
AUTOMOTIVE PAINT FINISH

SHEET CONTENT:

ARCHITECTURAL PLANS SHALL


PREVAIL OVERALL ENGINEERING
PLANS W/ REGARDS TO
DIMENSIONS AND SIZES. ANY
DISCREPANCIES FOUND HEREIN,
SHALL BE VERIFIED W/ THE
ARCHITECT.

SHEET NO:

ELEVATION - 'A'
ELEVATION - 'B'

AR-20

DRAWN BY: TOMRUS

DATE : 01-18-16

CHECKED BY:

DATE :