Sei sulla pagina 1di 4

JUZER A TINWALA

CONSULTING STRUCTURAL ENGINEER,


502 5th FLOOR,
SHREEJI KRUPA CO-OP SOC-LTD,
SAMUEL STREET,
MASJID BUNDER (W),
MUMBAI.

Sub: Typical Design Calculations


Design of Smartdek 51 Decking Sheet
Data:
Selfweight of 0.7mm(BMT) sheet = 7.35 Kg/ m 2
75 mm thk. average total flooring = 0.075x2400 = 180 Kg/ m 2
Live load = Kg/ m2
Zinc coating on decking sheet = 0.275 Kg/ m2
Total Dead load on decking sheet = 188Kg/M2
Centre to centre distance between continuous supporting beams = 2.25m.
Grade of decking sheet = 550 N/mm 2.
Design:
For 1m. width of decking sheet,
Max. bending moment at support (next to the end support)
= (188x2.25x2.25)/10 + (75x2.25x2.25)/9 Kgm.
= 95.175 +42.19 Kgm
= 137.36 Kgm.
Max. bending moment at middle span (near middle of end support)
= (188x2.25x2.25)/12 + (75x2.25x2.25)/10 Kgm.
= 79.31+37.97 Kgm
= 117.28 Kgm.
Max. shear force (at support next to end support)
= 0.6 (188x2.25 + 75x2.25) Kg.

= 355.05 Kg.
Check for bending:Section modulus required = M/st
= 137.36x1000x10/330
= 4162.4 mm 3<< 15156.25 mm3 (O.K.)
Check for Shear :Max. shear stress = 355.05 x10/(1000x0.7)
= 5.072 N/mm2 << 220 N/mm2 (0.4x550) (O.K.)
Max. deflection = wl4/ (185 EI)
= 2.630x 22504/(185x 200000x409687.5)
= 4.45 mm << 6 mm(span/350) (O.K.)
Design of Member ( A ) Supporting Deck Slab
Selfweight of memb (A)(2ISMC125) = 25.4 Kg/ m
Total load from decking slab = 591.75Kg/m
Load from false ceiling( @40 Kg/m2) = 90Kg/m
Total load on memb (A) ,(w) = 707.15Kg/m =7.07KN/m.
Centre to centre distance between continuous supporting beams = 4.25m.
Max. bending moment = wl2/10 = 7.07x4.25x4.25/10 = 12.77 KNm.
Max. shear force = 0.6Xwl = 7.07x4.25x0.6 = 18.02 KN.
Check for bending:Section modulus required = M/st
= 12.77x1000000/165
= 76969.7 mm3<< 133200 mm3 (O.K.)
Check for Shear :Max. shear stress = 18.02 x1000/(2X5X108.8)
= 16.56 N/mm2 << 100 N/mm2 (0.4x250) (O.K.)

Max. deflection = wl4/ (185 EI)


= 7.07x 42504/(185x 200000x2X416.4X10000)
= 7.46 mm << 12.14 mm(span/350) (O.K.)
Design of Member ( B ) Hanged from Slab to Support Catwalk of 1.8 m. width
Width of catwalk = 1.8 m.
Centre to centre spacing of vertical member (Hanger) = 1.5 m.
Length of hanger = 2.1m.
Loading:1) Selfweight of 4 mm. thk. chequered plate = 0.004x7850 = 31.4 Kg/m 2
2) Live Load = 100 Kg/m2
3) Parapet (ms grill ) load = 50 50 Kg/m at edge of catwalk.
Load on Hanger:i)
Selfweigth of hanger(Tata Tube 91.5x91.5x4.5) = 11.88x2.1 = 24.95 Kg.
ii)
Load form chequered plate = 31.4x1.5x0.9 = 42.39 Kg.
iii)
Live load = 1.5x0.9x100 = 135 Kg.
iv)
Load from horizontal memb(B) = 11.88x(1.5+0.9) = 28.512 Kg.
v)
Load from parapet = 50x1.5 = 75 Kg.
Total load on memb(B) = 305.85 Kg.
Net cross section area required = 305.85x10/150
= 20.39 mm 2<< 1514 mm2.
Check for slenderness ratio:Effective length = 2.1 m. = 210 cm.
Least ratio of gyration = 1.85 cm.
Slenderness ratio = 210/1.85 = 113.51 << 350 (Hence, O. K.)
Check for Anchor bolts
Capacity of single bolts = 0.8x(113x80) = 7232 N. = 7.232 KN.
Total load on anchor bolts = wt. of end plate + load on hanger
=( 0.3x0.3x0.012x7850 + 305.85) Kg.
= 314.33 Kg. = 3.143 KN.
No. of anchors required = 3.143/7.232 = 0.43 <<4( Min. nos. of bolts.)
Hence, O.K.
Design of Horizontal Member(Tata Tube 91.5x91.5x4.5)
Effective length = 1.8 m.
Load on member(B):-

vi)
vii)
viii)

Selfweigth of memb(B)(Tata Tube 91.5x91.5x4.5) = 11.88 Kg/m..


Load form chequered plate = 31.4x1.5 = 47.1 Kg/m.
Live load = 1.5x100 = 150 Kg/m.
Total load on memb(B) = 208.98 Kg/m.

Max. bending moment = wl2/10 = 208.98x1.8x1.8/10 = 84.64 Kg m.


Max. shear force = 0.5Xwl = 208.98x1.8x0.5 = 188.08 Kg.
Check for bending:Section modulus required = M/st
= 84.64x10x1000/158.4
= 5343.43 mm3<< 187570 mm3 (O.K.)
Check for Shear :Max. shear stress = 188.08 x10/(2X4.5X82.5)
= 2.53 N/mm2 << 96 N/mm2 (0.4x240) (O.K.)

Potrebbero piacerti anche