Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
AC 800M Hardware
n CPU
n Communication Interfaces
n I/O Connections
n Hardware Redundancy
ABB University - 2
Revision C-d1
CPU
CPU PM8xx
Fuses for
Modulebus and
CEX-bus
CPU
PM8XX Baseplate
TP830
TP830port
2RS-232 serial ports:
COM3 modem support(modbus)
COM4 port(TK212).IPf.w upgrade
1ModulebusIO module()
Revision C-d1
The CPU has 64 Mbyte memory and runs with 133 MHz clock
frequency double memory size and 40% higher cyclic performance
PM866 Yes Yes
compared to PM864. PM866 is available either as single or as
Revision C-d1
Applications
Warm Init .
retain
.CBM
RestartWarm
Applications
Cold Init Init < 2.5
cold retain
CBMRestartCold
set IP
Revision C-d1
CPU
Battery
Internal External
CPU Type
Internal External NOTE:CF Card
min time (hours) min time (weeks)
APPCold Retain Value.
PM851/PM856/PM860 48 4
PM861 36 4 APPCBM
PM864 36 3 CF card.
PM861A 118 12
ABB University - 6
PM864A 235 24
Cold Retain Value
PM865 HI 235 24
Revision C-d1
CBMCF Card
PM865 PA 235 24
PM866 158 15
.
CPU
AC 800M Ports
Communication CEX_bus
expansion CPU
(CEX bus) Electrical
Modulebus
RS-232 ports
COMLI (data transfer), MODBUS and
S3964R
64MBCF Card
application(s).
CF CardApplication.
ES.
CF CardApplicationCF Crad
ES.
CF CardCrashMemory dump to CF
Card
ABB University - 8
Revision C-d1
n CPU
n Communication Interfaces
n I/O Connections
n Hardware Redundancy
ABB University - 9
Revision C-d1
Communication
Interfaces Communication Interface Units
On-line
Unit Description Redundancy
replacement
CI860 Yes No
HSE
Revision C-d1
Communication
Interfaces Communication Exchange Bus - CEX Bus
12
CEX-bus
TB850
.:
TB850 (male) or TB851 (female)
TK850 with DB25P and TB851
or
.TK850
(length of 0.7 meter)DB25P
ABB University - 11
Revision C-d1
Communication
Interfaces BC810 and TP857 - CEX-Bus Interconnection Unit
BC810CEX-BUS
Redundancy
CEX-Bus(
)
C1 /Yellow CEX-
BUS(service and standby BC 810)
C2 /Yellow interconnect
ABB University - 12
standby BC810(service )
Revision C-d1
Communication
Interfaces CI854-Profibus DP V1
D9Profibus.
TP854
.
ABB University - 13
Revision C-d1
Communication
Interfaces CI853-RS232
75 ~ 19200 bps
Modem
protocols
ABB University - 14
Revision C-d1
AC 800M
Hardware AC 800M Hardware
n CPU
n Communication Interfaces
n I/O Connections
n Hardware Redundancy
ABB University - 15
Revision C-d1
I/O
Connections I/O Connection Possibilities
I/O :
Modulebus (electrical or )
Profibus DP(ref 3BDS009029R4001 p19).
I/O clusterCI830(Profibus)
TB820(Modulebus) I/O.
I/O cluster12I/O (
I/Oloading).
7modem
1 cluster(CPU loading
ModuleBus )
extension
Optical Modulebus
Simplex or Duplex,
.
I/O cluster 2 I/O cluster 3 I/O cluster 4
TB820CBM.
I/O modules in cluster
number
ABB University - 17
8-base cluster
Revision C-d1
303-3 cluster
Duplex
Simplex max. 15 or 200m
max. 15 or 200m
I/O
Connections S800 I/O Connected with Profibus
CI830
Profibus slave
max 15 or 200m
Revision C-d1
I/O
Connections S800 I/O Connected with Profibus
CI851position number =1
CI830position number=1
ProfiBus node.
CI830
ABB University - 19
Revision C-d1
I/O
Connections ABB Range of I/O Units
S800 modular I/O
S800L I/O
This is a compact I/O with an integrated
I/O and terminal unit. This I/O cannot
be replaced on-line.
S200 I/O
This I/O must be connected through an
APB12 ProfiBus module.
S900 I/O
This I/O must be connected through a
CI920 ProfiBus module. The I/O is
suitable for use in hazardous areas.
ABB University - 20
S100 I/O
Revision C-d1
2 - Wire
3 Wire
Compact 4 Wire
()
ABB University - 21
Revision C-d1
I/O
Connections Module Termination Units
Extended
ABB University - 22
Revision C-d1
AC 800M
Hardware AC 800M Hardware
n CPU
n Communication Interfaces
n I/O Connections
n Hardware Redundancy
ABB University - 23
Revision C-d1
Hardware
Redundancy Redundant CPUs
Communication
Bus (CEX) 1
TK850 Upper CPU TK850BC810
Interconnect
1.TK850
2
1
2.Control network
.:
Lower CPU .
3.ModuleBus
RCU Link Cable .
TK851
ABB University - 25
Revision C-d1
Hardware
Redundancy Controller and I/O Redundancy
CEX -bus splitter
BC810
Redundant or Singular
S800 I/O
Optical ModuleBus
Cable
BC810-.
ABB University - 26
RedundancyI/O-(12Module6Module)
Revision C-d1
Hardware
Redundancy Modulebus I/O Redundancy
RedundancyI/O
-(12Module6Module)
ABB University - 27
Revision C-d1
Hardware
Redundancy Profibus I/O Redundancy
CEX -bus splitter
BC810
Redundant
PROFIBUS CI
CI854A
TU846 or TU847
Redundant or Singular
S800 I/O
ABB University - 28
Revision C-d1
Hardware
Redundancy Summary Full Redundancy
ProfiBus DP CEX-Bus
RCU Link
ProfiBus
DP-V1 ModuleBus
Optic Cable
Redundant ModuleBus
Solution
ABB University - 29
SV5.0 Sp2
ABB University - 36
Revision C-d1
Use
SoftController ProjectSoftcontroller-(8/9)
ABB University - 37
Revision C-d1
Use
SoftController ProjectSoftcontroller-(9/9)
ABB University - 38
Revision C-d1
ABB University - 39
Revision C-d1