Sei sulla pagina 1di 3

11/11/2016

whyuse420mAinthefieldofinstrumentation?
SignUp(/mypanel.php?register) Login(/mypanel.php)

Categories(/interviewquestions/all.html)>>Engineering(/interviewquestions/79/engineering.html)>>Instrumentation

SuggestNewCategory

StartDownload
Merge&ConvertFilesGoto
download.easydocmerge.com

StartDownloadPDFNow
ConvertAnyFiletoaPDF.GettheFreeFromDoc
toPdfApp!Gotofromdoctopdf.com

WirelessanalogI/Omodule
toconnectPLCwithsensors
05Vor420mAsignalwirelesstransmission,analog
acquisitionmodule,AI,AOGotolensen
tech.com/Product/AnalogIOmodule

GlobeControlValvefrmIndia
PressureTempFlowControls
DiaphragmOperated,LimitSwitch,Positioner,SS,CS
andOtherExoticMaterialsGotoblissflowsystems.com

whyuse420mAinthefieldofinstrumentation?
QuestionPosted/Ujjal.Mondal11

7Answers
15797Views
IalsoFaced

EMailAnswers

AnswersWereSortedBasedOnUser'sFeedback

Answer(/Viewpost/281941/IfUse020maInsted420MaNotFindActualPositionZeroReferenceOutputExam.Html)/VijayRanipa
ifweuse0to20mainstedof4to20mathenwecannot
findactualpositionzeroreferenceoutput,forexampleif
wehaveamotorizedvalve,it'sfullcloseatthattimewe
get0ma(0%)referenceandatfullyopenpositionweget
20ma(100%)reference,inthisconditionifpowersupplyofis
offthenwealsoget0mareference,sohereinthiskindof
conditionwecan'tgetactualresultlikethatgateis
actuallycloseoranyotherproblemsasperexplanationof
above..
IsThisAnswerCorrect?

31Yes

7No

submit

Answer(/Viewpost/352477/2Reasons1AllMicroControllersPlcDcsEtcOperated5VoltsSupplyEx1vlow5.Html)/ChiruMudra...
Therer2reasonsforthis.....
1)Allmicrocontrollers,plc,dcsetc.,areoperatedwith1
to5voltssupply.(Ex:1v=low,5v=high).
Attheinput&outputofthesedevicesweuse250ohm
resistorforconvertingthis420mAto15volts.
ie4mA*250ohms=1Volt
20mA*250ohms=5Volts.......
2)Ifweusethisrangefrom1mAtosomerangethereisa
problemwiththat.
whichis,inindustriesweusebunchofcablestogetherfrom
fieldtocontrolroomandviceverse.Duetothisthereis
somesignaldistortionintheothercablesduetomagnetic
induction(electromagneticinductioneffectintheother
cables).ie,12mAcurrentwillgenerateintheunactivated
cableswhichmaycausethemallfninthetotalindustry.

http://www.allinterview.com/showanswers/119787/whyuse420mainthefieldofinstrumentation.html

1/3

11/11/2016

whyuse420mAinthefieldofinstrumentation?

Ex:1mA=0%valveopen
2mA=10%valveopen
3mA=20%valveopen....etc.
IsThisAnswerCorrect?

25Yes

4No

submit

Answer(/Viewpost/276601/FieldInstrumentsLikeVoltageCurrentEtcAdvantageUsing420maIfSensorsKno.Html)/Vijay
wehavefieldinstrumentslikevoltage,current..etc.but
thereisanadvantageofusing420mA,Ifweareusingthe
voltagesensors,uknowthevoltageisresistance
dependence,andresistaceofcoductorvariesasthedistance
andtemperature,varies.soumaynotgettheaccuratesignal
ifupreferforthevoltagesensors.usingcurrentsensorsu
don'tfindthisproblems
IsThisAnswerCorrect?

22Yes

8No

submit

Answer(/Viewpost/276738/AboveAnswerCorrectNeedDeadZeroSoUsing420MaInstead116Ma.Html)/Ajith294
Theaboveansweriscorrect.wehavetoneedthedeadzero,
soweareusing4to20mAinsteadof1to16ma
IsThisAnswerCorrect?

12Yes

8No

submit

Answer(/Viewpost/441228/420maUseInstrumentationFeildBcozConsider116maDifficultFindError.Html)/Diya.
420mAisuseininstrumentationfeild,bcozwhenweconsider116mAthereisdifficulttofinderrorinthat...
IsThisAnswerCorrect?

4Yes

0No

submit

Answer(/Viewpost/316143/AlsoTheSignalIsLinearIn420maRangeWhichIsNotBelow4maOrAbove20ma.Html)/Anand
alsothesignalislinearin420mArangewhichisnotbelow
4mAorabove20mA.
IsThisAnswerCorrect?

7Yes

6No

submit

Answer(/Viewpost/442818/Use420MaOutPutBecauseSignalGoesFieldFromControlRoomConverted3Psi.Html)/Bhagwan
Weuse420mAoutputbecausethissignalgoestothefield(fromcontrolroomtothefield,)whereitisthenconvertedfrom3psito15psiasoutputtocontrol
theflow,tempersture,pressureetc.
Inthecontrolroom,thesamesignalisconvertedfrom15voltstoreadmeasureflow,temperatures,pressureandatthesametime,itissentbacktooutput
card
toconvert420mA.to315p.s.I.toactuatecontrolValve.
AsthedistancebeweenControlRoom&thefieldisveryfar,sothelosesfortransfering420mA.arenill.
IsThisAnswerCorrect?

0Yes

2No

submit

PostNewAnswer
Categories
http://www.allinterview.com/showanswers/119787/whyuse420mainthefieldofinstrumentation.html

2/3

11/11/2016

whyuse420mAinthefieldofinstrumentation?

CivilEngineering(4388)(/interviewquestions/80/civilengineering.html)
MechanicalEngineering(3625)(/interviewquestions/81/mechanicalengineering.html)
ElectricalEngineering(15356)(/interviewquestions/82/electricalengineering.html)
ElectronicsCommunications(2599)(/interviewquestions/83/electronicscommunications.html)
ChemicalEngineering(572)(/interviewquestions/84/chemicalengineering.html)
AeronauticalEngineering(78)(/interviewquestions/85/aeronauticalengineering.html)
BioEngineering(30)(/interviewquestions/86/bioengineering.html)
Metallurgy(94)(/interviewquestions/87/metallurgy.html)
IndustrialEngineering(190)(/interviewquestions/88/industrialengineering.html)
Instrumentation(2799)(/interviewquestions/366/instrumentation.html)
AutomobileEngineering(132)(/interviewquestions/580/automobileengineering.html)
MechatronicsEngineering(40)(/interviewquestions/587/mechatronicsengineering.html)
MarineEngineering(58)(/interviewquestions/595/marineengineering.html)
PowerPlantEngineering(146)(/interviewquestions/599/powerplantengineering.html)
EngineeringAllOther(1310)(/interviewquestions/117/engineeringallother.html)

MoreInstrumentationInterviewQuestions
Howtocalibratethecontrolvalve.

1Answers(/showanswers/181385/howtocalibratethecontrolvalve.html)
Whatismeantbycoldfloatofcompressorshaft.

1Answers(/showanswers/181265/whatismeantbycoldfloatofcompressorshaft.html) Sabic(/company/1893/sabic.html),
1.ForSteamdrumlevelsignal,whydowecompensatewithdrumpressuresignal?2.FormainsteamFlowsignaliscomensatedwithmainsteamtemperature
signalandmainsteampressuresignalwhy?

0Answers(/showanswers/105065/1steamdrumlevelsignalcompensatepressure2mainflowcomensatedtemperature.html)
whypneumaticcontrolsignaloutputisuse0.2to1kg/cm2

http://www.allinterview.com/showanswers/119787/whyuse420mainthefieldofinstrumentation.html

3/3

Potrebbero piacerti anche