9. Table A-1B of B 31.3 Code gives weld joint quality factor for manufactured
pipes. The factor can be increased for Electric Fusion welded pipes by
conducting additional radiography (spot or full) as per Table 302.3.4.
10. Minimum Required Thickness
,weld point factor (E) and made from material having safe stress (S),
Material co-efficient (Y) and subjected to internal pressure (P) is given by:
PD
Min.Req.Thickness tm = ------------- + C
2(SE + PY)
where C = corrosion allowance.
11. The thickness calculated shall be corrected for 12.5% negative
tolerance.
12. Thickness of a permanent blank for the pipe is given by:
t m dg
3P
C
16 SE