Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Taurus 70 CED
MO-S-113
24.05.2012
Ie H
Page 1 of 14
MO-S-113
24.05.2012
E
Thermocouple Port
2nd Stage Nozzle
2nd Stage Blades
2nd Stage Tip Shoe
Blade Retaining Pins
3rd Stage Nozzle
3rd Stage Tip Shoe
3rd Stage Blades
VGV
External Variable
Guide Vanes
IGV
00 Stage VGV
0 Stage VGV
1st Stage VGV
2nd Stage VGV
A
Air inlet
Air Inlet Duct
Air Inlet Screen
Compressor Inlet GV
00 Stage Blades
00 Stage GV
D
Fuel Injectors
Compressor Exit GV
Injectors
Combustor Interior
Combustor Pins
Torch Tube
Sliding Ring
1st Stage Nozzle
1st Stage Blades
RGB
Inspection Port
Pinion & Star Gear Star
Gear 2nd stage
Accessory Gear
Low Speed Brg
Borescope Port
4th Stage Blades
4th Stage GV
5th Stage Blades
Borescope Port
11th Stage Blades
11th Stage GV
12th Stage Blades
Page 2 of 14
MO-S-113
24.05.2012
Access
Location
Air Inlet
Picture
Description
Inspection for
Severity
a) Potential FOD
None
b) Corrosive
Pitting
None
c) Cracks
None
d) Excessive
fouling
None
a) Potential FOD
None
b) Cracks,
damaged mesh
None
a) Nicks and
dents. Quantity
and size
None
b) Excess of
fouling
None
Air Inlet
Air Inlet
None
c) Corrosive
pitting. Affected
area
Page 3 of 14
MO-S-113
24.05.2012
Access
Location
Air Inlet
Picture
Description
Inspection for
Severity
00 Stage
Compressor Blades
a) Nicks and
dents. Quantity
and size.
None
b) Excessive
fouling
None
c) Corrosive
pitting. Affected
area.
None
None
a) Nicks and
dents. Quantity
and size.
Superfici
al nicks
Air Inlet
00 Stage Guide
Vanes
b) Excessive
fouling
c) Corrosive
pitting. Affected
area.
None
None
Page 4 of 14
MO-S-113
24.05.2012
Access
Location
Borescope
Port
Picture
Description
Inspection for
Severity
4th Stage
Compressor Blades
a) Nicks and
dents. Quantity
and size.
None
b) Excessive
fouling
None
c) Corrosive
pitting. Affected
area.
None
None
a) Nicks and
dents. Quantity
and size.
None
b) Excessive
fouling
None
c) Corrosive
pitting. Affected
area.
None
a) Nicks and
dents. Quantity
and size.
None
b) Excessive
fouling
None
c) Corrosive
pitting. Affected
area.
None
None
Borescope
Port
4th Stage
Compressor GV
Borescope
Port
5th Stage
Compressor Blades
Page 5 of 14
MO-S-113
24.05.2012
Access
Location
Borescope
Port
Picture
Description
Inspection for
Severity
11th Stage
Compressor Blades
a) Nicks and
dents. Quantity
and size.
None
b) Excessive
fouling
None
c) Corrosive
pitting. Affected
area.
None
None
a) Nicks and
dents. Quantity
and size.
None
b) Excessive
fouling
Rust on
both
sides
Borescope
Port
11th Stage
Compressor GV
c) Corrosive
pitting. Affected
area.
Borescope
Port
12th Stage
Compressor Blades
None
a) Nicks and
dents. Quantity
and size.
None
b) Excessive
fouling
None
c) Corrosive
pitting. Affected
area.
None
None
Page 6 of 14
MO-S-113
24.05.2012
Access
Location
Fuel
Injectors
Picture
Description
Inspection for
Severity
Compressor Exit GV
a) Nicks and
dents. Quantity
and size.
None
b) Excessive
fouling.
None
c) Corrosive
pitting. Affected
area.
Quite
advance
d rust
a) Pilot
Centerbody
erosion.
None
b) Fuel hole
contamination or
blockage.
Sulfidatio
n
Fuel
Injectors
Injectors
c) Cracks.
Quantity and size.
d) Liquid only:
broken main fuel
spokes.
Fuel
Injectors
Combustor Interior
None
None
a) Cracks.
Quantity and size
None
b) Thermal
Erosion.
None
c) Hot spots.
None
d) Buckling or
warpage.
None
Page 7 of 14
MO-S-113
24.05.2012
Access
Location
Fuel
Injectors
Picture
Description
Inspection for
Severity
Combustor Pins
a) Cracks.
None
Torch Tube
a) Thermal
erosion.
None
Clamp ring/Sliding
Ring
a) Thermal
erosion. Depth
and affected area.
None
Fuel
Injectors
Fuel
Injectors
Page 8 of 14
MO-S-113
24.05.2012
Access
Location
Fuel
Injectors
Fuel
Injectors
Picture
Description
Inspection for
Severity
a) Cracks.
Quantity, length,
and orientation.
None
b) Thermal
erosion. Depth
and affected area.
None
c) F.O.D. Affected
area
None
a) Cracks.
Quantity, length,
and orientation.
None
b) Thermal
erosion. Depth
and affected area.
None
c) F.O.D. Affected
area
None
None
Page 9 of 14
MO-S-113
24.05.2012
Access
Location
T5 Port
T5 Port
T5 Port
Picture
Description
Inspection for
Severity
a) Cracks.
Quantity, length,
and orientation.
None
b) Cracks.
None
c) Thermal
erosion. Depth
and affected area.
None
a) Cracks.
Quantity, length,
and orientation.
None
b) Thermal
erosion. Depth
and affected area.
None
c) F.O.D. Affected
area
None
None
a) Cracks.
Quantity, length,
and orientation.
None
b) Cracks.
None
c) Thermal
erosion. Depth
and affected area.
None
Page 10 of 14
MO-S-113
24.05.2012
Access
Location
T5 Port
Picture
Description
Inspection for
Severity
a) Cracks.
Quantity, length,
and orientation.
None
b) Thermal
erosion. Depth
and affected area.
None
c) F.O.D. Affected
area
None
None
Page 11 of 14
MO-S-113
24.05.2012
Access
location
External
VGV
Picture
Description
Inspection for
Severity
IGV
a) Cracks
None
b) Lever arms
bent
None
c) Grommet out
of position on
unison ring
None
d) Corrosion
None
a) Cracks
None
b) Lever arms
bent
None
c) Grommet out
of position on
unison ring
None
d) Corrosion
None
a) Cracks
None
b) Lever arms
bent
None
c) Grommet out
of position on
unison ring
None
d) Corrosion
None
VGV
External
VGV
00 Stage VGV
VGV
External
VGV
VGV
0 Stage VGV
Page 12 of 14
MO-S-113
24.05.2012
Access
location
External
VGV
Picture
Description
Inspection for
Severity
a) Cracks
None
b) Lever arms
bent
None
c) Grommet out
of position on
unison ring
None
d) Corrosion
None
a) Cracks
None
b) Lever arms
bent
None
c) Grommet out
of position on
unison ring
None
d) Corrosion
None
VGV
External
VGV
VGV
2s Stage VGV
Page 13 of 14
MO-S-113
24.05.2012
Access
location
Inspection
Port
Picture
Description
Inspection for
Severity
Pinion Double
Helical & Star Gear
a) Gear wear
None
b) Teeth Cracks
None
a) Gear wear
None
b) Teeth Cracks
None
a) Gear wear
None
b) Teeth Cracks
None
a) Wear
None
RGB
Inspection
Port
RGB
Inspection
Port
Accessory Gear
RGB
Inspection
Port
RGB
Page 14 of 14