Shuntrelease,110-130VAC/DC

Deliveryprogramme

Partno.
Articleno.
CatalogNo.

NZM2/3-XA110-130AC/DC
259760

Product range
Accessories
Accessories
Standard/Approval
Construction size
Description

Connection type
Auxiliary contacts
Rated control voltage
For use with

Us

Approvals

Product Standards
UL File No.
UL Category Control No.
CSA File No.
CSA Class No.
North America Certification

Shuntrelease

Rated control voltage

Accessories
Shunt release
Shunt releases
UL/CSA, IEC
NZM2/3
Switches are tripped by a voltage pulse
or by the application of uninterrupted
voltage.
When the shunt release is energized,
accidental contact with the main
contacts of the switch during attempts
to switch on is safely prevented.
Undervoltage releases cannot be
installed simultaneously with NZM...XHIV... early-make auxiliary contact or
NZM...-XU... shunt release.
- without entry without auxiliary contact
110 - 130 V AC/DC
NZM2(-4), N(S)2(-4)
NZM3(-4), N(S)3(-4)

UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking


E140305
DIHS
022086
1437-01
UL listed, CSA certified

Us

Us

V
AC

12 - 440

Us

V
DC

12 - 440

Hz

50/60/200/400, DC

x Us

0.7 - 1.1

x Us

0.7 - 1.1

VA/
W

2.5

2.5

Maximum opening delay (response time until opening of the main


contacts)
Maximum duty factor

VA/
W

ms

20

Minimum command time

ms

ms

AC
DC
Frequency range
Operating range
AC
DC
Power consumption
Pick-up AC/DC
Sealing AC/DC

Terminal capacities

10 15

Solid or flexible conductor, with ferrule

mm

mm

1 x (0.75 - 2.5)
2 x (0.75 - 2.5)

AWG

1 x (18 14)
2 x (18 14)

TechnicaldataETIM5.0

Low-voltage industrial components (EG000017) / Shunt release (for power circuit breaker) (EC001023)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Full load current trip (ecl@ss8-27-37-04-18
[AKF016009])
Rated control supply voltage Us at AC

V
110 - 130
50HZ
Rated control supply voltage Us at AC

V
110 - 130
60HZ
Rated control supply voltage Us at DC

V
110 - 130
Voltage type for actuating

AC/DC
Initial value of the undelayed short
A
0
circuit release - setting range
End value adjustment range undelayed

A
0
short-circuit release
03/20/2014

HPL-ED2014 V2.13 EN

1/2

Type of electric connection


Number of contacts as normally open
contact
Number of contacts as normally closed
contact
Number of contacts as change-over
contact
Suitable for power circuit breaker
Suitable for switch disconnector
Suitable for motor safety switch
Suitable for overload relay

Screw connection
0

Yes
Yes
No
No

Additionalproductinformation(links)

IL01208005Z(AWA1230-1915)Shuntrelease,Undervoltagerelease,Early-makeauxiliarycontact
IL01208005Z (AWA1230-1915) Shunt
release, Undervoltage release, Earlymake auxiliary contact

03/20/2014

ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL01208005Z2011_08.pdf

Eaton Industries GmbH


http://www.eaton.eu
02/2014 by Eaton Industries GmbH
HPL-ED2014 V2.13 EN

2/2