Sei sulla pagina 1di 3

Page 1 of 3

Address History with Inspection Log


CONTACT_TYPE = Complainant, Neighbor, Tenant/Occupant, Applicant
CONTACT_TYPE = Blank
ADDR_PARTIAL : Begins With 4631 CONGRESS
APN = (Blank)
DATE_OPENED >= 1/1/1980
DATE_OPENED <= 12/31/2020
RECORD_TYPE_SUBTYPE <> Soft Story Retrofit Validation

Record ID: 1202248


Address: 4631 CONGRESS AVE
APN: 036 241500400
Unit #:
Description: BAGS OF TRASH AND OVERFLOWING TRASH BINS LEFT IN FRONT, USED FURNITRUES LEFT IN FRONT OF THE
PROPERTY ALSO.

Date Opened: 5/15/2012


Record Status: Abated
Record Status Date: 5/24/2012
Job Value: $0.00
Requestor:
:
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments

Record ID: 1602047


Address: 4631 CONGRESS AVE
APN: 036 241500400
Unit #:
Description: MOLD IN BEDROOM, ON BED, BABY'S CRIB AND CLOTHING, PEELING PAINT, DOOR KNOBS NOT WORKING
PROPERLY

Date Opened: 6/6/2016


Record Status: Abated
Record Status Date: 9/20/2016
Job Value: $0.00
Requestor:

https://adhoc1.accela.com/AdhocReportWeb/Report/rs.aspx?p=htmlreport&print=1&refr...

10/27/2016

Page 2 of 3

: REYNA
Business Name:
License #:
Inspection Date
6/8/2016
7/14/2016
8/18/2016
9/16/2016

Inspector Name
Hugo
Hugo
Hugo
Hugo

Barron
Barron
Barron
Barron

Inspection Type

Status / Result

1st Inspection
Follow-up Inspection
Follow-up Inspection
Follow-up Inspection

Violation Verified
No Entry
Partially Abated
Abated

Result Comments

Record ID: RB1603187


Address: 4631 CONGRESS AVE
APN: 036 241500400
Unit #:
Description: Remove rear illegal addition (8'x10').

Date Opened: 7/7/2016


Record Status: Issued
Record Status Date: 7/7/2016
Job Value: $1,500.00
Requestor: RODRIGUEZ VICTOR M & MOLINA ROSA E
:
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments

Record ID: RE1402676


Address: 4631 CONGRESS AVE
APN: 036 241500400
Unit #:
Description: ELECTRICAL: METER RE-SET; REPLACE EXISTING MAIN PANEL. PG&E APPLICATION #109697326.

Date Opened: 12/3/2014


Record Status: Final
Record Status Date: 12/12/2014
Job Value: $0.00
Requestor: RODRIGUEZ VICTOR M & MOLINA ROSA E
: VICTOR RODRIGUEZ
Business Name:
License #:
Inspection Date
12/4/2014

Inspector Name
Ken Gunari

Inspection Type
Frame

Status / Result
Not Pass

Result Comments
1.Some wires with in panel are tapped. The previous
panel caught on fire and PGE cut power lines at pole.
Replaced damaged wires or provide letter from
licensed electrician stating wiring is not damaged and
is safe. 2) New service panel installed with 100 amp
back fed breaker. Breaker requires hold down kit. 3)
Install arc fault breakers for circuits where current
code requires. 4) Aluminum wire requires anti oxidant
compound at terminals. 5) I was informed that a 220
V clothes dryer is within the front house. The breaker
for this circuit is not a 220 Volt breaker. Install code
complying breaker. Note: I was informed by person at

https://adhoc1.accela.com/AdhocReportWeb/Report/rs.aspx?p=htmlreport&print=1&refr...

10/27/2016

Page 3 of 3

12/12/2014

Kim Nguyen

Final Electrical
Final Electrical

Pass
Pending

site that rear building is a single family dwelling that


appears to be undocumented and with research that
was performed by Senior Inspector Jorges Reyes,, he
was not able to find records for rear dwelling.. Please
provide records (3R report.) that building at rear of
parcel is a legal Single Family Dwelling. Please have
buildings accessible for safety check. The panel size
and feeder size may not be adequate for load. Load
calculations may be required. Senior Inspector will
open up code case for potential violations.
Utility release ok.

Record ID: WB9900939


Address: 4631 CONGRESS AVE
APN: 036 241500400
Unit #:
Description: SECURITY BAR INSPECTION AND FEES PAID FOR COMPLIANCE

Date Opened: 7/21/1999


Record Status: Expired
Record Status Date: 3/7/2000
Job Value: $0.00
Requestor: RODRIGUEZ VICTOR M & MOLINA RO
:
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments

Record ID: ZW1600329


Address: 4631 CONGRESS AVE
APN: 036 241500400
Unit #:
Description: Code enforcement: it is okay to remove rear illegal addition (8'x10').

Date Opened: 7/7/2016


Record Status: Complete
Record Status Date: 7/7/2016
Job Value:
Requestor:
: Victor Rodriguez
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments

For real-time, direct access to


information via the Internet, 24
hours a day https://aca.accela.com/oakland

https://adhoc1.accela.com/AdhocReportWeb/Report/rs.aspx?p=htmlreport&print=1&refr...