Sei sulla pagina 1di 218

ADD CELSELRESEL

SET DRD
ADD INTERFREQNCELL
ADD CAC
SET IDLEMODETIMER
SET CONNMODETIMER
IRAT HO PARAMETER
ADD CELLHSDPA

INDEX

Set RNC Oriented DRD Algorithm Parameters(SET DRD)


Function
Note
Parameter
Example
Function

Set the RNC-oriented Directed Retry Decision (DRD) algorithm parameters.


The DRD algorithm is used to select a suitable cell during the cell resource admission procedure f
- Current cell load
- Cell type
- Traffic type
- Intelligent networking strategy
- Cell resource admission result
The following functions are available:
- RRC setup DRD
- RAB setup DRD
- RAB modification DRD
- DCCC with channel switch DRD
Note

None.
Parameter

ID

Name

ServiceDiffDrdSwitch

Service differential drd switch

LdbDRDSwitchDCH

Load balance DRD switch for DCH

LdbDRDSwitchHSDPA

Load balance DRD switch for


HSDPA

LdbDRDchoice

Load balance DRD choice

RrcRedictSwitch

RRC redirect switch

LdbDRDOffsetDCH

Load balance DRD offset for


DCH[%]

LdbDRDOffsetHSDPA

Load balance DRD offset for


HSDPA[%]

LdbDRDLoadRemainThd Dl load balance DRD power


DCH
remain threshold for DCH[%]

LdbDRDLoadRemainThd Dl load balance DRD power


DCH
remain threshold for DCH[%]

LdbDRDLoadRemainThd Dl load balance DRD power


HSDPA
remain threshold for HSDPA[%]

LdbDRDTotalPwrProThd

Load balance DRD total power


protect threshold[%]

CodeBalancingDrdSwitc
h
Code balance drd switch

DeltaCodeOccupiedRate Delta code occupied rate[%]

CodeBalancingDrdMinSF Minimum SF threshold for code


Thd
balance drd

CodeBalancingDrdCode Code occupied rate threshold for


RateThd
code balance drd[%]

CodeBalancingDrdCode Code occupied rate threshold for


RateThd
code balance drd[%]

ReDirBandInd

ReDirection target band indicator

ReDirUARFCNUplinkInd

Redirection target UL frequency


configuration ind

ReDirUARFCNUplink

Redirection target uplink UARFCN

ReDirUARFCNDownlink

Redirection target downlink


UARFCN

Example

To set the RNC-oriented DRD algorithm parameters, run the following command:
SET DRD: ServiceDiffDrdSwitch=ON;
After the command is run, the [ServiceDiffDrdSwitch] parameter is set to ON.

ers(SET DRD)

) algorithm parameters.
cell during the cell resource admission procedure for RRC or RAB. The algorithm is affected by the following fac

Description
Value range: ON, OFF.
Physical unit: None.
Content: This parameter specifies whether the service differential DRD algorithm will be applied.
- ON: The service differential DRD algorithm will be applied.
- OFF: The service differential DRD algorithm will not be applied.
Recommended value: OFF.
Value range: ON, OFF.
Physical unit: None.

Content:This parameter specifies whether the load balancing DRD algorithm will be applied for service
carried on DCH.
- ON: The load balancing DRD algorithm will be applied.
- OFF: The load balancing DRD algorithm will not be applied.
Recommended value: OFF.
Value range: ON, OFF.

Physical unit: None.

Content: This parameter specifies whether the load balancing DRD algorithm will be applied for servic
carried on HS-DSCH.
- ON: The load balancing DRD algorithm will be applied.
- OFF: The load balancing DRD algorithm will not be applied.
Recommended value: OFF.
Value range: Power~1, UserNumber~0
Physical unit: None.
Content: This parameter specifies which choice the load balancing DRD algorithm will be applied.

- Power: Power(Downlink none-HSDPA power is used for services carried on DCH, and downlink HSDPA
guarantee power is used for services carried on HS-DSCH)will be applied to the load balancing DRD al

- UserNumber: User number(Downlink R99 equivalent user number is used for services carried on DCH
downlink HSDPA user number is used for services carried on HS-DSCH)will be applied to the the load
balancing DRD algorithm.
Recommended value: UserNumber.
Value range: OFF~0, Only_To_Inter_Frequency~1, Allowed_To_Inter_RAT~2.
Physical unit: None.
Content: This parameter specifies the RRC redirection strategy.
- OFF: RRC redirection is not allowed.
- Only_To_Inter_Frequency: Only RRC redirection to inter-frequency cells is allowed.

- Allowed_To_Inter_RAT: RRC redirection to inter-frequency cells and redirection to inter-RAT cells are bo
allowed.
Recommended value: Only_To_Inter_Frequency.
Value range: 0~100.
Physical value range: 0%~100%.
Physical unit: %.

Content: This parameter specifies the threshold of remanent load offset between the current cell and
target cell when load balancing DRD is applied for DCH users. Only when the remanent load offset rea
this threshold can a neighboring cell be selected as a candidate DRD cell for DCH users.
Recommended value: 10.
Value range: 0~100.
Physical value range: 0%~100%.
Physical unit: %.

Content: This parameter specifies the threshold of remanent load offset between the current cell and
target cell when load balancing DRD is applied for HSDPA users. Only when the remanent load offset r
this threshold can a neighboring cell be selected as a candidate DRD cell for HSDPA users.
Recommended value: 10.
Value range: 0~100.
Physical value range: 0%~100%.
Physical unit: None.

Content: This parameter specifies the downlink load threshold to trigger load balancing DRD for servic
carried on DCH. The load balancing DRD will probably be triggered only when the downlink cell reman
H power or remanent R99 equivalent user number is less than this threshold.
Recommended value: 35.
Value range: 0~100.
Physical value range: 0%~100%.
Physical unit: %.

Content: This parameter specifies the downlink load threshold to trigger load balancing DRD for servic
carried on HS-DSCH. The load balancing DRD will probably be triggered only when the downlink cell re
HSDPA guarantee power or remanent HSDPA user number is less than this threshold.
Recommended value: 100.
Value range: 0~100.
Physical value range: 0%~100%.
Physical unit: %.

Content: This parameter specifies the threshold of the downlink remanent total power difference betw
current cell and the target cell when load balancing DRD is applied and the load balancing DRD choice
Power. Only when the downlink remanent total power difference is less than this threshold can a neigh
cell be selected as a candidate DRD cell.
Recommended value: 30.
Value range: ON, OFF.
Physical unit: None.
Content: This parameter specifies whether the code balancing DRD algorithm will be applied.
- ON: The code balancing DRD algorithm will be applied.
- OFF: The code balancing DRD algorithm will not be applied.
Recommended value: OFF.
Value range: 0~100.
Physical value range: 0%~100%.
Physical unit: None.

Content: This parameter specifies the threshold of code occupancy offset between the current cell and
target cell when code balancing DRD is applied. Only when the cell code occupancy offset reaches thi
threshold can a neighboring cell be selected to be a candidate cell for DRD.
Recommended value: 7.
Value range: SF4~0, SF8~1, SF16~2, SF32~3, SF64~4, SF128~5, SF256~6.
Physical unit: None.

Content: This parameter specifies one of the triggering conditions of code balancing DRD. (The other
condition is the code occupancy.) This condition refers to that the minimum spreading factor of the be
not smaller than the value of this parameter.
Recommended value: SF8.
Value range: 0~100.
Physical value range: 0%~100%.
Physical unit: %.

Content: This parameter specifies one of the triggering conditions of code balancing DRD. (The other
condition is the minimum spreading factor.) This condition refers to that the code occupancy in the be
not lower than the value of this parameter.
Recommended value: 13.
Value range: Band1, Band2, Band3, Band4, Band5, Band6, Band7, Band8, Band9, DependOnNCell,
BandIndNotUsed.
Physical unit: None.
Content: This parameter specifies the target frequency band in the redirection procedure.
Recommended value: DependOnNCell.
Value range: TRUE, FALSE.
Physical unit: None.

Content: This parameter specifies whether the UL frequency of the target cell of redirection needs to b
configured.
- TRUE: The UL frequency needs to be configured.
- FALSE: The UL frequency does not need to be configured. It is configured automatically according to
relationship between UL and DL frequencies.
Recommended value: None.
Value range: Depending on the band indication, as shown below:
Band1:
Common frequencies: [9612-9888]
Special frequencies: none
Band2:
Common frequencies: [9262-9538]
Special frequencies: {12, 37, 62, 87, 112, 137, 162, 187, 212, 237, 262, 287}
Band3:
Common frequencies: [937-1288]
Special frequencies: none
Band4:
Common frequencies: [1312-1513]
Special frequencies: {1662, 1687, 1712, 1737, 1762, 1787, 1812, 1837, 1862}
Band5:
Common frequencies: [4132-4233]
Special frequencies: {782, 787, 807, 812, 837, 862}
Band6:
Common frequencies: [4162-4188]
Special frequencies: {812, 837}
Band7:
Common frequencies: [2012-2338]

Special frequencies: {2362, 2387, 2412, 2437, 2462, 2487, 2512, 2537, 2562, 2587, 2612, 2637, 266
2687}
Band8:
Common frequencies: [2712-2863]
Special frequencies: none
Band9:
Common frequencies: [8762-8912]

Special frequencies: none


BandIndNotUsed:
[0-16383]

Content: This parameter specifies the target uplink UARFCN of a cell for RRC redirection. Assume that
target uplink UARFCN for RRC redirection is unspecified, the band indication is Band1, Band2, Band3,
Band5, Band6, Band7, Band8, or Band9, and the target downlink UARFCN for RRC redirection is valid.
the default target uplink UARFCN for RRC redirection is as follows:
- If the DL frequency belongs to common frequencies, then
Band1: Uplink UARFCN = Downlink UARFCN - 950
Band2: Uplink UARFCN = Downlink UARFCN - 400
Band3: Uplink UARFCN = Downlink UARFCN - 225
Band4: Uplink UARFCN = Downlink UARFCN - 225
Band5: Uplink UARFCN = Downlink UARFCN - 225
Band6: Uplink UARFCN = Downlink UARFCN - 225
Band7: Uplink UARFCN = Downlink UARFCN - 225
Band8: Uplink UARFCN = Downlink UARFCN - 225
Band9: Uplink UARFCN = Downlink UARFCN - 475
- If the DL frequency belongs to special frequencies, then
Band2: Uplink UARFCN = Downlink UARFCN - 400
Band4: Uplink UARFCN = Downlink UARFCN - 225
Band5: Uplink UARFCN = Downlink UARFCN - 225
Band6: Uplink UARFCN = Downlink UARFCN - 225
Band7: Uplink UARFCN = Downlink UARFCN - 225
Recommended value: None.
Value range: Depending on the band indication, as shown below:
Band1
Common frequencies: [10562-10838]
Special frequencies: none
Band2
Common frequencies: [9662-9938]
Special frequencies: {412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687}
Band3
Common frequencies: [1162-1513]
Special frequencies: none
Band4
Common frequencies: [1537-1738]
Special frequencies: {1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087}
Band5
Common frequencies: [4357-4458]
Special frequencies: {1007, 1012, 1032,1037, 1062, 1087}
Band6
Common frequencies: [4387-4413]
Special frequencies: {1037, 1062}

Band7
Common frequencies: [2237-2563]

Special frequencies: {2587, 2612, 2637, 2662, 2687, 2712, 2737, 2762, 2787, 2812, 2837, 2862, 288
2912}
Band8
Common frequencies: [2937-3088]
Special frequencies: none
Band9
Common frequencies: [9237-9387]
Special frequencies: none
BandIndNotUsed:[0-16383]
Physical unit: None.
Content: This parameter specifies the target downlink UARFCN of a cell for RRC redirection.
Recommended value: None.

, run the following command:

h] parameter is set to ON.

INDEX
Add Cell Selection And Reselection Information(ADD CELLSELRESEL)
Function
Note
Parameter
Example
Function

Add cell selection and reselection information.


Note

None.
Parameter

ID

CellId

Name

Cell ID

Cell Sel-reselection quality


QualMeas measure

IdleQhyst Hysteresis 1 for idle


1s
mode[2dB]

ConnQhys Hysteresis 1 for connect


t1s
mode[2dB]

IdleQhyst Hysteresis 2 for idle


2s
mode[2dB]

ConnQhys Hysteresis 2 for connect


t2s
mode[2dB]

Treselectio
ns
Reselection delay time[s]

Qqualmin Min quality level[dB]

Qrxlevmin Min Rx level[2dBm]

Qrxlevmin Min Rx level[2dBm]

Qrxlevmin
ExtSup
Min Rx level Extend Support

DeltaQrxle
vmin
Delta Min Rx level

MaxAllow
edUlTxPo Max allowed UE UL TX
wer
power[dBm]

IdleSintras Intra-freq cell reselection


earch
threshold for idle mode[2dB]

IdleSinters Inter-freq cell reselection


earch
threshold for idle mode[2dB]

IdleSinters Inter-freq cell reselection


earch
threshold for idle mode[2dB]

Intra-freq cell reselection


ConnSintr threshold for connect
asearch
mode[2dB]

Inter-freq cell reselection


ConnSinte threshold for connect
rsearch
mode[2dB]

SsearchRa Inter-RAT cell reselection


t
threshold[2dB]

SpeedDep
endentSca Speed dependent scaling
lingFactor factor for reselection delay

InterFreqTr
eselScalin Inter-frequency scaling
gFactor
factor for reselection delay

InterRatTr
eselScalin Inter-RAT scaling factor for
gFactor
reselection delay

NonhcsInd Non-HCS indicator

Tcrmaxno
nhcs
Non-HCS max TCR[s]

Ncrnonhcs Non-HCS NCR

Ncrnonhcs Non-HCS NCR

Tcrmaxhys Non-HCS TCR max


tnonhcs
hysteresis[s]

Hysteresis 1 for UE in
Qhyst1spc CELL_PCH or URA_PCH
h
state[dB]

Qhyst1sfa Hysteresis 1for UE in


ch
CELL_FACH state[dB]

Hysteresis 2 for UE in
Qhyst2spc CELL_PCH or URA_PCH
h
state[dB]

Qhyst2sfa Hysteresis 2 for UE in


ch
CELL_FACH state[dB]

Treselectio Reselection delay time for


nspch
UE in PCH state[s]

Treselectio Reselection delay time for


nspch
UE in PCH state[s]

Treselectio Reselection delay time for


nsfach
UE in CELL_FACH state[0.2s]
Example

Add cell selection and reselection parameters to Cell1.


ADD CELLSELRESEL: CellId=1, QualMeas=CPICH_ECNO, IdleQhyst1s=2, ConnQhyst1s=2, IdleQhyst2s
After the above operations, the cell reselection parameters are added toCell1 as follows:
1.Cell Sel-reselection quality measure is CPICH Ec/No.
2.Hysteresis 1 for idle mode is 4 dB.
3.Hysteresis 1 for connect mode is 4 dB.
4.Hysteresis 2 for idle mode is 4 dB.
5.Hysteresis 2 for connect mode is 4 dB.
6.The cell reselection delay time is 1s.
7.The minimum quality level of CPICH Ec/No is -18 dB.
8.The minimum Rx level of CPICH RSCP is -116 dBm.
9.The maximum allowed uplink transmit power of a UE in the cell is 21 dBm.
10.The intra-frequency cell reselection threshold for idle state and connect state is 6 dB.
11.The inter-frequency cell reselection threshold for idle state and connect state is 10 dB.
12.The inter-RAT cell reselection threshold is 4 dB.
13.Speed dependent scaling factor for reselection is 0.2.
14.Inter-frequency scaling factor for reselection is 2.5.
15.Inter-RAT scaling factor for reselection is 2.5.
16.The non-HCS speed estimation parameters are configured.
17.The time for non-HCS maximum cell reselection is not used.
18.The non-HCS maximum number of cell reselection is 8.
19.The extra time before a UE resumes its low mobility in a non-HCS cell is not used.
20.Hysteresis 1 for UE in CELL_PCH or URA_PCH state is 5 dB.
21.Hysteresis 1for UE in CELL_FACH state is 5 dB.
22.Hysteresis 2 for UE in CELL_PCH or URA_PCH state is 5 dB.
23.Hysteresis 2 for UE in CELL_FACH state is 5 dB.
24.Reselection delay time for UE in PCH state is 3s.
25.Reselection delay time for UE in CELL_FACH state is 0.6s.

tion Information(ADD CELLSELRESEL)

on information.

Description
Value range: 0~65535
Physical unit: None
Content: Uniquely identifying a cell
Recommended value: None
Value range: CPICH_ECNO(CPICH Ec/N0), CPICH_RSCP(CPICH RSCP)
Physical unit: None

Content: Measurement quantity of cell selection and reselection. It can be set to CPICH Ec/N0 or CPICH
information of this parameter, refer to 3GPP TS 25.304.
Recommended value: CPICH_ECNO
Value range: 0~20
Physical value range: 0~40; step: 2
Physical unit: dB

Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement f
reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is lo
fading variance is, the greater this parameter.

According to the R regulation, the current serving cell involves in cell selection after the measuremen
hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselec
slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location
updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network sig
of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow
timely cell updates of the UE. According to the CPICH RSCP emulation report of inter-frequency hard h
hysteresis ranges 4 dBm to 5 dBm and is set to 4 dBm by default when the slow fading variance is 8 d
20 m. In the cells where the slow fading variance is low and the average moving speed of UEs is high,
countryside, reduce the measurement hysteresis to guarantee timely location updates of UEs. The hig
hysteresis is, the less likely it is for various types of cell reselections to occur, and the better the slow
but the slower the system reacts to the environment changes. For detailed information of this parame
Value range: 0~20
Physical value range: 0~40; step: 2
Physical unit: dB.

Content: The hysteresis value of the serving FDD cells in connected mode in case the quality measure
reselection is set to CPICH RSCP. It is related to the slow fading feature of the area where the cell is lo
fading variance is, the greater this parameter.

According to the R regulation, the current serving cell involves in cell selection after the measuremen
hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselec
slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location
updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network sig
of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow
timely cell updates of the UE. According to the CPICH RSCP emulation report of inter-frequency hard h
hysteresis ranges 4 dBm to 5 dBm and is set to 4 dBm by default when the slow fading variance is 8 d
20 m. In the cells where the slow fading variance is low and the average moving speed of UEs is high,
countryside, reduce the measurement hysteresis to guarantee timely location updates of UEs. The hig
hysteresis is, the less likely it is for various types of cell reselections to occur, and the better the slow
but the slower the system reacts to the environment changes. For detailed information of this parame
Recommended value: 2
Value range: {{0~20},{255}}
Physical value range: 0~40; step: 2
Physical unit: dB.

Content: The hysteresis value of the serving FDD cells in idle mode in case the quality measurement f
reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is lo
fading variance is, the greater this parameter. It is optional. If it is not configured, [Hysteresis 1] will b
parameter is not configured when its value is 255.

According to the R regulation, the current serving cell involves in cell selection after the measuremen
hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselec
slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location
updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network sig
of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow
timely cell updates of the UE. According to the CPICH RSCP emulation report of inter-frequency hard h
hysteresis ranges 4 dBm to 5 dBm and is set to 4 dBm by default when the slow fading variance is 8 d
20 m. In the cells where the slow fading variance is low and the average moving speed of UEs is high,
countryside, reduce the measurement hysteresis to guarantee timely location updates of UEs. The hig
hysteresis is, the less likely it is for various types of cell reselections to occur, and the better the slow
but the slower the system reacts to the environment changes. For detailed information of this parame
Recommended value: the same as Qhyst1s for idle mode
Value range: {{0~20},{255}}.
Physical value range: 0~40; step: 2.
Physical unit: dB.

Content: The hysteresis value of the serving FDD cells in connected mode in case the quality measure
reselection is set to CPICH Ec/No. It is related to the slow fading feature of the area where the cell is lo
fading variance is, the greater this parameter. This parameter is not configured when its value is 255.

According to the R regulation, the current serving cell involves in cell selection after the measuremen
hysteresis value. The measurement hysteresis aims to prevent the ping-pong effect of the cell reselec
slow fading when the UE is on the edge of the cell. The ping-pong effect may trigger frequent location
updates (URA_PCH), or cell updates (CELL_FACH, CELL_PCH), and thus increase the load of network sig
of UE batteries. Set a proper measurement hysteresis to reduce as much as possible effect of the slow
timely cell updates of the UE. According to the CPICH RSCP emulation report of inter-frequency hard h
hysteresis ranges 4 dBm to 5 dBm and is set to 4 dBm by default when the slow fading variance is 8 d
20 m. In the cells where the slow fading variance is low and the average moving speed of UEs is high,
countryside, reduce the measurement hysteresis to guarantee timely location updates of UEs. The hig
hysteresis is, the less likely it is for various types of cell reselections to occur, and the better the slow
but the slower the system reacts to the environment changes. For detailed information of this parame
Recommended value:the same as Qhyst1s for connect mode.
Value range: 0~31
Physical unit: s

Content: If the signal quality (CPICH Ec/No measured by the UE) of a neighboring cell is better than th
the specified time of this parameter, the UE reselects the neighboring cell. It is used to avoid ping-pon
different cells. Note that the value 0 corresponds to the default value defined in the protocol.
Set the parameter as follows:

1. Ensure that the UE can reselect a cell when crossing the non-soft-switch area of the cell and that th
updates, cell updates, or URA updates when necessary.
2. Ensure that the UE does not reselect a cell when it is in the soft-switch area of the cell. In this way,
updates, cell updates, and URA updates are avoided.

3. Consider the difference between cells that cover different areas, for example the cells covering hig
densely populated areas. TIf the parameter is set to a comparatively low value, the ping-pong reselec
parameter can be increased in populated area and reduced in high-speed movement. If the paramete
high value, the cell reselection delay may become excessively high, and thus cell reselections may be
For detailed information, refer to 3GPP TS 25.304.
Recommended value: 1
Value range: -24~0
Physical unit: dB

Content: The minimum required quality threshold corresponding to CPICH Ec/No. The UE can camp on
measured CPICH Ec/No is greater than the value of this parameter. The higher the parameter value is,
UE to reside in the cell. The lower parameter value is, the easier it is for the UE to reside in the cell, bu
cannot receive the system messages that are sent through the PCCPCH. For detailed information, refe
Recommended value: -18
Value range: -58~-13
Physical value range: -115~-25; step: 2 (-58:-115; -57:-113; ...; -13:-25 )
Physical unit: dBm

Content: The minimum required RX threshold corresponding to CPICH RSCP. The UE can camp on the
CPICH RSCP is greater than the value of this parameter. The setting of Qrxlevmin should be related to
parameter is, the more difficult it is for the UE to reside in the cell. The lower parameter is, the easier
cell, but it is possible that the UE cannot receive the system messages that are sent through the PCCP
refer to 3GPP TS 25.304.
Recommended value: -58
Value range: TRUE, FALSE
Physical unit: none

Content: Indicating whether the minimum required RX level is extended. For detailed information of th
TS 25.304.
Recommended value: FALSE
Value range: -2, -1
Physical value range: -4, -2; step: 2 (-2: -4; -1:-2)
Physical unit: none
Content: Actual minimum required RX level = minimum required RX level + extended minimum requi
Recommended value: none
Value range: -50~33
Physical unit: dBm

Content: The maximum allowed uplink transmit power of a UE in the cell, which is related to the netw
information, refer to 3GPP TS 25.304.
Recommended value: 24
Value range: {{-16~10},{127}}
Physical value range: -32~20; step: 2
Physical unit: dB

Content: Threshold for intra-frequency cell reselection in idle mode. When the quality (CPICH Ec/No m
serving cell is lower than this threshold plus the [Qqualmin] of the cell, the intra-frequency cell resele
started. This parameter is not configured when its value is 127. The intra-frequency cell reselection ha
inter-frequency cell reselection and inter-RAT cell reselection, the intra-frequency cell reselection start
than the inter-frequency cell reselection start threshold and inter-RAT cell reselection start threshold. I
is set to a comparatively high value, the UE may frequently start cell reselections, and the battery of t
consumed. If the cell reselection threshold is set to a comparatively low value, it is difficult for cell res
the UE may not timely reside in the cells with good quality, affecting the quality of communication be
For detailed information, refer to 3GPP TS 25.304.
Recommended value: None
Value range: {{-16~10},{127}}
Physical value range: -32~20; step: 2
Physical unit: dB

Content: Threshold for inter-frequency cell reselection in idle mode. When the quality (CPICH Ec/No m
cell is lower than this threshold plus the [Qqualmin] of the cell, the inter-frequency cell reselection pro
parameter is not configured when its value is 127. The intra-frequency cell reselection has a priority h
cell reselection and inter-RAT cell reselection, the intra-frequency cell reselection start threshold shou
frequency cell reselection start threshold and inter-RAT cell reselection start threshold. If the cell resel
comparatively high value, the UE may frequently start cell reselections, and the battery of the UE may
cell reselection threshold is set to a comparatively low value, it is difficult for cell reselections to be st
timely reside in the cells with good quality, affecting the quality of communication between the UTRA
information, refer to 3GPP TS 25.304.
Recommended value: None
Value range: {{-16~10},{127}}
Physical value range: -32~20; step: 2
Physical unit: dB.

Content: Threshold for intra-frequency cell reselection in connected mode. When the quality (CPICH E
the serving cell is lower than this threshold plus the [Qqualmin] of the cell, the intra-frequency cell res
started. This parameter is not configured when its value is 127. The intra-frequency cell reselection ha
inter-frequency cell reselection and inter-RAT cell reselection, the intra-frequency cell reselection start
than the inter-frequency cell reselection start threshold and inter-RAT cell reselection start threshold. I
is set to a comparatively high value, the UE may frequently start cell reselections, and the battery of t
consumed. If the cell reselection threshold is set to a comparatively low value, it is difficult for cell res
the UE may not timely reside in the cells with good quality, affecting the quality of communication be
For detailed information, refer to 3GPP TS 25.304.
Recommended value: None
Value range: {{-16~10},{127}}.
Physical value range: -32~20; step: 2.
Physical unit: dB.

Content: Threshold for inter-frequency cell reselection in connected mode. When the quality (CPICH E
serving cell is lower than this threshold plus the [Qqualmin] of the cell, the inter-frequency cell reselec
This parameter is not configured when its value is 127. The intra-frequency cell reselection has a prior
frequency cell reselection and inter-RAT cell reselection, the intra-frequency cell reselection start thres
the inter-frequency cell reselection start threshold and inter-RAT cell reselection start threshold. If the
set to a comparatively high value, the UE may frequently start cell reselections, and the battery of the
consumed. If the cell reselection threshold is set to a comparatively low value, it is difficult for cell res
the UE may not timely reside in the cells with good quality, affecting the quality of communication be
For detailed information, refer to 3GPP TS 25.304.
Recommended value: None.
Value range: {{-16~10},{127}}
Physical value range: -32~20; step: 2
Physical unit: dB

Content: Threshold for inter-RAT cell reselection. When the quality (CPICH Ec/No measured by UE) of t
this threshold plus the [Qqualmin] of the cell, the inter-RAT cell reselection procedure will be started. T
configured when its value is 127. This parameter is not configured when its value is 127. The intra-fre
priority higher than the inter-frequency cell reselection and inter-RAT cell reselection, the intra-frequen
threshold should be higher than the inter-frequency cell reselection start threshold and inter-RAT cell r
the cell reselection threshold is set to a comparatively high value, the UE may frequently start cell res
the UE may be largely consumed. If the cell reselection threshold is set to a comparatively low value,
reselections to be started, and the UE may not timely reside in the cells with good quality, affecting th
between the UTRAN and the UE. For detailed information, refer to 3GPP TS 25.304.
Recommended value: None
Value range: {{{0~10},{255}}
Physical value range: 0~1; step: 0.1
Physical unit: None

Content: For a high-mobility UE, multiples this parameter by its reselection delay to reduce the resele
parameter can be set to 10 for middle-speed UE, which means no influence upon reselection delay tim
configured when its value is 255. For detailed inforamtion, refer to 3GPP TS 25.304.
Recommended value: None
Value range: {{4~19},{255}}
Physical value range: 1~4.75.step: 0.25
Physical unit: None

Content: This parameter is used to increase time of inter-frequency reselection. It is not configured wh
detailed inforamtion, refer to 3GPP TS 25.304.
Recommended value: None
Value range: {{4~19},{255}}
Physical value range: 1~4.75.step: 0.25
Physical unit: None

Content: This parameter is used to increase time of inter-RAT reselection. It is not configured when its
inforamtion, refer to 3GPP TS 25.304.
Recommended value: None
Value range: CONFIGURED, NOT_CONFIGURED
Physical unit: None
Content: Indicating whether the non-HCS speed estimation parameter should be configured.
Recommended value: None
Value range: not used, D30, D60, D120, D180, D240
Physical value range: not used, 30, 60, 120, 180, 240
Physical unit: s

Content: Maximum duration of non-HCS cell reselection. If the number of cell reselection exceed the v
Tcrmaxnonhcs, the UE is not in high-speed movement. For detailed inforamtion, refer to 3GPP TS 25.3
Recommended value:NotUsed
Value range: 1~16
Physical unit: None

Content: Maximum number of non-HCS cell reselection. This parameter, along with Tcrmaxnonhcs, de
threshold of non-HCS cells. For detailed inforamtion, refer to 3GPP TS 25.304.

Recommended value: 8
Value range: not used, D10, D20, D30, D40, D50, D60, D70
Physical value range: not used, 10, 20, 30, 40, 50, 60, 70
Physical unit: s

Content: Hysterisis time before non-HCS resuming slow movement. When UE is in high-speed movem
reselections is less than Ncrnonhcs, the UE resumes to slow movement. For detailed inforamtion, refe
Recommended value: NotUsed
Value range: {{0~40},{255}}
Physical unit: dB

Content: This parameter indicates that in the CELL_PCH or URA_PCH connection mode, the measurem
is used when CPICH RSCP is used in cell selection and reselection measurement. This parameter is no
255.

Otherwise, the greater the parameter value is, the harder the cell selection happens. For detailed info
25.304.
Recommended value: None
Value range: {{0~40},{255}}
Physical unit: dB

Content: This parameter indicates that in the CELL_FACH connection mode, the measurement hystere
when CPICH RSCP is used in cell selection and reselection measurement. This parameter is not config

Otherwise, the greater the parameter value is, the harder the cell selection happens. For detailed info
25.304.
Recommended value: None
Value range: {{0~40},{255}}
Physical unit: dB

Content: This parameter indicates that in the CELL_PCH or URA_PCH connection mode, the measurem
is used when CPICH EcNo is used in cell selection and reselection measurement. This parameter is no
255.

Otherwise, the greater the parameter value is, the harder the cell selection happens. For detailed info
25.304.
Recommended value: None
Value range: {{0~40},{255}}
Physical unit: dB

Content: This parameter indicates that in the CELL_FACH connection mode, the measurement hystere
when CPICH EcNo is used in cell selection and reselection measurement. This parameter is not configu

Otherwise, the greater the parameter value is, the harder the cell selection happens. For detailed info
25.304.
Recommended value: None
Value range: {{0~31},{255}}
Physical unit: s

Content: This parameter indicates the UE reselection delay in the CELL_PCH or URA_PCH connection m
configured when the value is 255. Instead, the Treselections parameter is used. For detailed inforamti

Recommended value: None


Value range: {{0~31},{255}}
Physical value range: 0~6.2; step: 0.2
Physical unit: s

Content: This parameter indicates the UE reselection delay in the CELL_FACH connection mode. This p
when the value is 255. Instead, the Treselections parameter is used. For detailed inforamtion, refer to
Recommended value: None

on parameters to Cell1.
QualMeas=CPICH_ECNO, IdleQhyst1s=2, ConnQhyst1s=2, IdleQhyst2s=2, ConnQhyst2s=2, Treselections=1, Qq

cell reselection parameters are added toCell1 as follows:


easure is CPICH Ec/No.

e is 4 dB.

e is 4 dB.

CPICH Ec/No is -18 dB.


CH RSCP is -116 dBm.
transmit power of a UE in the cell is 21 dBm.
election threshold for idle state and connect state is 6 dB.
election threshold for idle state and connect state is 10 dB.
n threshold is 4 dB.
ctor for reselection is 0.2.
or for reselection is 2.5.
eselection is 2.5.
ion parameters are configured.
mum cell reselection is not used.
mber of cell reselection is 8.
resumes its low mobility in a non-HCS cell is not used.
PCH or URA_PCH state is 5 dB.
FACH state is 5 dB.
PCH or URA_PCH state is 5 dB.
FACH state is 5 dB.
E in PCH state is 3s.
E in CELL_FACH state is 0.6s.

in=-58, MaxAllowedUlTxPower=21, IdleSintrasearch=3, IdleSintersearch=5, ConnSintrasearch=3, ConnSinterse

rch=3, ConnSintersearch=5, SsearchRat=2, SpeedDependentScalingFactor=2, InterFreqTreselScalingFactor=10

selScalingFactor=10, InterRatTreselScalingFactor=10, NonhcsInd=CONFIGURED, Tcrmaxnonhcs=NotUsed, Ncrn

nhcs=NotUsed, Ncrnonhcs=8, Tcrmaxhystnonhcs=NotUsed, Qhyst1spch=5, Qhyst1sfach=5, Qhyst2spch=5, Qh

5, Qhyst2spch=5, Qhyst2sfach=5, Treselectionspch=3, Treselectionsfach=3;

INDEX
Add Inter-frequency Neighboring Cell(ADD INTERFREQNCELL)
Function
Note
Parameter
Example
Function

Add inter-frequency neighboring cell information.


Note

1. It is not mandatory to configure inter-frequency neighboring cells in pairs, e.g. Cell 2 might not be o
2. Before adding an inter-frequency neighboring cell, check whether this cell belongs to the local RNC
3.One cell's inter-frequency neighbour cells with same downlink frequency and uplink frequency are li
Parameter

ID

Name

CellId

Cell ID

RncId

RNC ID of neighboring
cell

NCellId

Neighboring cell ID

Neighboring cell
CIOOffset oriented CIO[0.5dB]

SIB11Ind

SIB11 Indicator

SIB11Ind

SIB11 Indicator

IdleQoffse
t1sn
IdleQoffset1sn[dB]

IdleQoffse
t2sn
IdleQoffset2sn[dB]

SIB12Ind

SIB12 Indicator

ConnQoffs
et1sn
ConnQoffset1sn[dB]

ConnQoffs
et2sn
ConnQoffset2sn[dB]

TpenaltyH HCS Cell Reselect


csReselect Penalty Timer[s]

TempOffse HCS Cell Reselect


t1
TempOffset1[dB]

TempOffse HCS Cell Reselect


t1
TempOffset1[dB]

TempOffse HCS Cell Reselect


t2
TempOffset2[dB]

The priority of
coverage based interHOCovPrio frequency handover

BlindHOFl
ag
Blind handover flag

BlindHOQ
ualityCon Blind handover
dition
condition[dBm]

NPrioFlag The flag of the priority

NPrio

The priority of
neighbor cell

NPrio

The priority of
neighbor cell

DRDEcN0
Threshhol Drd Ec/N0
d
threshold[dB]
Example

To add for the cell 1 an inter-frequency neighboring cell 100 with the following configuration:
1. RNC ID of neighboring cell: 9
2. Neighboring cell ID: 100
3. Cell offset: 0
4. SIB11 Indicator: TRUE
5. SIB12 Indicator: FALSE
6. HCS Cell Reselect Penalty Timer: D0
7. The priority of coverage based inter-frequency handover: 1
8. Blind handover flag: FALSE
9. The flag of the priority: FALSE
Execute the following command:
ADD INTERFREQNCELL: CellId=1, RncId=9, NCellId=100, CIOOffset=0, SIB11Ind=TRUE, SIB12Ind=FAL

hboring Cell(ADD INTERFREQNCELL)

hboring cell information.

configure inter-frequency neighboring cells in pairs, e.g. Cell 2 might not be one of cell 1's neighboring cells whi
-frequency neighboring cell, check whether this cell belongs to the local RNC or another RNC. If the cell belongs
cy neighbour cells with same downlink frequency and uplink frequency are limited to 32.

Description
Cell ID
Value range: 0~65535
Content: uniquely identifying a cell
Recommended value (default value): none
ID of the RNC controlling a neighboring cell
Value range: 0~4095
Content: uniquely identifying an RNC
Neighboring cell ID
Value range: 0~65535
Content: uniquely identifying a neighboring cell
Recommended value (default value): none
Neighboring cell oriented Cell Individual Offset (CIO)
Value range: -20 ~ 20
Physical value range: -10~10,step:0.5
Physical unit: dB

Content: This parameter defines the neighboring cell oriented cell individual offset. The set value func
oriented CIO. Their sum is added to the measurement quantity before the UE evaluated whether an e
algorithms, this parameter is used for moving the border of a cell.
Recommended value (default value): 0
Flag of whether to include this neighboring relationship in the System Information Block 11 (SIB11)
Value range: TRUE, FALSE
Content:

This parameter indicates whether the neighboring cell information is delivered in SIB11. FALSE: not to
information in the SIB11. TRUE: to include the neighboring information in the SIB11.
Recommended value (default value): TRUE
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in idle mo
Value range: -50~50
Physical unit: dB
Content:

Offset of neighboring cell CPICH measurement value. This parameter is used for RSSI measurement. T
neighboring cell measurement value before cell reselection.

This parameter defines the offset of cell CPICH RSCP measurement value in cell selection or reselectio

In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter ca
planner according to reality.
NOTE:
In FDD mode, this parameter is valid only when SIB11 Indicator is set as TRUE.
For details, refer to 3GPP TS 25.331.
As for the impact on network performance:

The larger the value of the parameter, the lower the probability of selecting neighboring cells. The sm
higher the probability of doing so.
Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in idle m
Value range: -50~50
Physical unit: dB
Content:
Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement.
neighboring cell measurement value before cell reselection.

In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter ca
planner according to reality.
NOTE:
In FDD mode this parameter is valid only when SIB11 Indicator is set as TRUE.
For details, refer to 3GPP TS 25.331.
As for the impact on network performance:

The larger the value of the parameter, the lower the probability of selecting neighboring cells. The sm
higher the probability of doing so.
Recommended value (default value): 0
Flag of whether to include this neighboring relationship in the System Information Block 12 (SIB12)
Value range: TRUE, FALSE
Content:

This parameter indicates whether the neighboring cell information is delivered in SIB12. FALSE: not to
information in the SIB12. TRUE: to include the neighboring information in the SIB12.
Recommended value (default value): FALSE
Offset of cell CPICH RSCP measurement value in cell selection or reselection when the UE is in connec
Value range: -50~50
Physical unit: dB
Content:

This parameter is used for cell offset in cell selection and reselection. During cell reselection, the cell
is QOffset2sn, that to CPICH RSCP is QOffset1sn. Idle is used for idle mode, and Conn for connected m
ConnQoffset2sn are valid only when SIB12Ind = TRUE, namely, the SIB12 message is existing.

Offset of neighboring cell CPICH measurement value This parameter is used for RSCP measurement. T
neighboring cell measurement value before cell reselection.

In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter ca
Network Planner(RNP) according to reality.
For details, refer to 3GPP TS 25.331.
As for the impact on network performance:

The larger the value of the parameter, the lower the probability of selecting neighboring cells. The sm
higher the probability of doing so.
Recommended value (default value): 0
Offset of cell CPICH Ec/No measurement value in cell selection or reselection when the UE is in connec
Value range: -50~50
Physical unit: dB
Content:

This parameter is used for cell offset in cell selection and reselection. During cell reselection, the cell
is QOffset2sn, that to CPICH RSCP is QOffset1sn. Idle is used for idle mode, and Conn for connected m
ConnQoffset2sn are valid only when SIB12Ind=TRUE, namely, the SIB12 message is existing.
Offset of neighboring cell CPICH measurement value This parameter is used for Ec/No measurement.
neighboring cell measurement value before cell reselection.

In cell reselection algorithm, this parameter is used for moving the border of a cell. This parameter ca
Network Planner(RNP) according to reality.
For details, refer to 3GPP TS 25.331.
As for the impact on network performance:

The larger the value of the parameter, the lower the probability of selecting neighboring cells. The sm
higher the probability of doing so.
Recommended value (default value): 0
HCS cell reselection penalty timer
Value range: D0, D10, D20, D30, D40, D50, D60
Content:
Physical value range: 0, 10, 20, 30, 40, 50, 60
Unit: s

This parameter indicates the penalty time after the HCS cell reselection. During the penalty time perio
HCS cell reselection.
The larger the value of the parameter, the longer the HCS penalty time.
The smaller the value of the parameter, the shorter the HCS penalty time.
Recommended value (default value): D0
Offset of HCS cell CPICH RSCP measurement value in cell selection or reselection
Value range: D3, D6, D9, D12, D15, D18, D21, Infinity
Content:
Physical value range: 3, 6, 9, 12, 15, 18, 21, Infinity
Unit: dB

This is the offset of cell CPICH RSCP measurement value in HCS cell selection or reselection. The large
lower the probability of selecting neighboring cells.
The smaller the value of the parameter, the higher the probability of doing so.
Recommended value (default value): D3
Offset of cell CPICH Ec/No measurement value in cell selection or reselection
Value range: D2, D3, D4, D6, D8, D10, D12, Infinity
Content:
Physical value range: 2, 3, 4, 6, 8, 10, 12, Infinity
Physical unit: dB
This parameter defines the offset of cell CPICH Ec/No measurement value in cell selection or reselecti
The larger the value of the parameter, the lower the probability of selecting neighboring cells.
The smaller the value the parameter, the higher the probability of doing so.
Recommended value (default value): D2
Priority of coverage-based inter-frequency handover
Value range: 0~3
Content:
"0" means that the coverage-based inter-frequency handover is not supported.
"1" means the highest priority.
"3" means the lowest priority.
Recommended value (default value): 1
Flag of target cell for blind handovers
Value range: TRUE, FALSE
Content:
This parameter indicates whether the neighboring cell is the target cell for blind handovers.
If the value is TRUE, blind handovers can be performed to the neighboring cell.
Recommended value (default value): FALSE
Blind handover condition
Value range: -115~-25
Physical unit: dBm
Content:

If the value is not -115, the handover is defined as Conditional Blind HO, which is used for the inter-fre
same coverage.

If the value is -115, the handover is defined as Direct Blind HO, which is used for the inter-frequency n
Recommended value (default value): -92
Priority identifier of neighboring cells
Value range: TRUE, FALSE
Content:

TRUE indicates that the neighboring cell priority is valid in the algorithm of neighboring cell combinat
neighboring cell priority is invalid, and, in the algorithm of neighboring cell combination, the cell with
considered as the measurement object.
Recommended value (default value): FALSE
Priority of neighboring cells
Value range: 0~63
Content:

The priority that corresponds to the neighboring cell is valid only when the this parameter is set to TR
easier it is for the neighboring cell to be delivered as the measurement object. For example, it is more
priority 1 than a cell of priority 2 to be delivered as the measurement object.
Recommended value (default value): None
This parameter is used as the DRD Ec/No threshold of whether to perform the blind handover.
Value range: -24~0
Physical value range: -12~0,step:0.5
Physical unit: dB

Content: This parameter is used as the DRD Ec/No threshold of whether to perform the blind handove
current cell is greater than this parameter of the inter-frequency neighboring cell, this neighboring cel
candidate DRD cell.
Recommended value: -18

ter-frequency neighboring cell 100 with the following configuration:

alty Timer: D0
e based inter-frequency handover: 1

ellId=1, RncId=9, NCellId=100, CIOOffset=0, SIB11Ind=TRUE, SIB12Ind=FALSE, TpenaltyHcsReselect=D0, HOC

e command ADD NRNCCELL to add the information of this cell first.

SE, NPrioFlag=FALSE;

INDEX

Add cell oriented CAC algorithm parameters(ADD CELLCAC)


Function
Note
Parameter
Example
Function

Add cell-oriented Call Admission Control (CAC) algorithm parameters.


In actual operation, it is necessary to set the CAC algorithm parameters based on the network manag
1. Set coverage ranges for various services: set the restrictions on the transmit power of different serv
2. Restrict services proportions in a cell: restrict the number of different services by setting different a
3. Optimize resource configuration (1): set different admission thresholds for conversational service, o
4. Optimize resource configuration (2): reserve resources for UL/DL common channels so as to guaran
There are 4 classes of services corresponding to different QoS requirements, as follows:
1. Conversational: This class corresponds to real-time services. The QoS requirement of this class is de
2. Streaming: This class corresponds to real-time streaming services, such as audio and video program
3. Interactive: This class corresponds to data services, such as terminal browsing. It has a strict BLER
4. Background: This class also corresponds to data services. It has a strict BLER requirement, but no tr
Note

1. [Cell environment type] is set to TU generally. In most cases, this parameter should not be changed
2. Following restriction must be satisfied:
1)[UL OLC trigger threshold] >= [UL total power threshold] > [UL handover access threshold] > [UL th
2)MAX(UL handover access threshold,UL threshold of Conv AMR service,UL threshold of Conv non_AM
3)[Ul HandOver Credit Reserved SF] >= [Ul LDR Credit SF reserved threshold];
4)[DL OLC trigger threshold] >= [DL total power threshold] >= [DL handover access threshold] > [DL
5)MAX(DL handover access threshold,DL threshold of Conv AMR service,DL threshold of Conv non_AM
6)[Dl HandOver Credit and Code Reserved SF] >= [Dl LDR Credit SF reserved threshold];
[Dl HandOver Credit and Code Reserved SF] >= [Cell LDR SF reserved threshold];
[MTCH maximal power] > [MTCH reserve power];
[MTCH maximal power SF] > [MTCH reserve SF].
7)[Ul TotalPower CAC threshold] > [UL Target LoadFactor].
The parameters of [UL LDR trigger threshold], [DL LDR trigger threshold], [UL OLC trigger threshold] a
Parameter

ID

CellId

Name

Cell ID

CellId

Cell ID

CellEnvType

Cell environment
type

UlNonCtrlThdForAMR

UL threshold of
Conv AMR
service[%]

UlNonCtrlThdForNonAMR

UL threshold of
Conv non_AMR
service[%]

UlNonCtrlThdForOther

UL threshold of
other
services[%]

UlNonCtrlThdForOther

UL threshold of
other
services[%]

DlConvAMRThd

DL threshold of
Conv AMR
service[%]

DlConvNonAMRThd

DL threshold of
Conv non_AMR
service[%]

DlOtherThd

DL threshold of
other
services[%]

UlNonCtrlThdForHo

UL handover
access
threshold[%]

DlHOThd

DL handover
access
threshold[%]

UlCellTotalThd

UL total power
threshold[%]

DlCellTotalThd

DL total power
threshold[%]

UlCCHLoadFactor

UL common
channel load
reserved
coefficient[%]

UlCCHLoadFactor

UL common
channel load
reserved
coefficient[%]

DlCCHLoadRsrvCoeff

DL common
channel load
reserved
coefficient[%]

UlTotalEqUserNum

UL total
equivalent user
number

DlTotalEqUserNum

DL total
equivalent user
number

Low priority
HsupaLowPriorityUserPBR HSUPA user PBR
Thd
threshold[%]

Equal priority
HsupaEqualPriorityUserPB HSUPA user PBR
RThd
threshold[%]

High priority
HsupaHighPriorityUserPB HSUPA user PBR
RThd
threshold[%]

UlHsDpcchRsvdFactor

UL HS-DPCCH
reserve
factor[%]

HsdpaStrmPBRThd

HSDPA
streaming PBR
threshold[%]

HsdpaBePBRThd

HSDPA best
effort PBR
threshold[%]

MaxHsdpaUserNum

Maximum HSDPA
user number

MaxHsdpaUserNum

Maximum HSDPA
user number

MaxUlTxPowerforConv

Max UL TX power
of conversational
service[dBm]

MaxUlTxPowerforStr

Max UL TX power
of streaming
service[dBm]

MaxUlTxPowerforInt

Max UL TX power
of interactive
service[dBm]

MaxUlTxPowerforBac

Max UL TX power
of background
service[dBm]

BackgroundNoise

Background
noise[0.1dBm]

DefPcpichEcNo

Default PCPICH
Ec/No[dB]

BGNSwitch

Auto-adaptive
background
noise update
switch

BGNAdjustTimeLen

Background
noise update
continuance
time[s]

BGNEqUserNumThd

Equivalent user
number
threshold for
background
noise

MaxHsupaUserNum

Maximum HSUPA
user number

DlHSUPARsvdFactor

DL HSUPA
reserved
factor[%]

DlMBMSRsvdFactor

DL MBMS
reserved
factor[%]

DlMBMSRsvdFactor

DL MBMS
reserved
factor[%]

MtchRsvPwr

MTCH reserve
power[%]

MtchRsvSf

MTCH reserve SF

MtchMaxPwr

MTCH maximal
power[%]

MtchMaxSf

MTCH maximal
SF

UlHoCeResvSf

UL handover
credit reserved
SF

DlHoCeCodeResvSf

DL handover
credit and code
reserved SF

BgnStartTime

Background
noise update
start time

BgnEndTime

Background
noise update end
time

BgnUpdateThd

Background
noise update
trigger threshold

BgnAbnormalThd

Background
noise abnormal
threshold

BgnAbnormalThd

Background
noise abnormal
threshold

MaxEFachUserNum

Maximum EFACH
user number

Example

Configure CAC parameters for cell 1.


ADD CELLCAC: CellId=1, CellEnvType=TU, NonorthoFactor=400, UlNonCtrlThdForAMR=75, DLConvAM

After the above operations, the parameters of cell 1 are set as follows:
The cell environment type is TU;
The nonorthogonality factor is 0.4;
The UL threshold of Conv AMR service is 0.75;
The UL threshold of Conv non_AMR service is 0.75;
The UL threshold of other services is 0.6;
The DL threshold of Conv AMR service is 80%;
The DL threshold of Conv non_AMR service is 80%;
The DL threshold of other services is 75%;
The UL handover access threshold is 0.8;
The DL handover access threshold is 85%;
The UL common channel load factor is 0.00.
The DL common channel load reserved coefficient is 0%;
The UL total equivalent user number is 80;
The DL total equivalent user number is 80;
The UL HS-DPCCH reserve factor is 0.00;
Hsdpa streaming PBR threshold is 70%;
Hsdpa best effort PBR threshold is 30%;
The maximum HSDPA user number is 64;
The maximum UL transmit power of conversational service is 24dBm;
The maximum UL transmit power of streaming service is 24dBm;
The maximum UL transmit power of interactive service is 24dBm;
The maximum UL transmit power of background service is 24dBm;
The background noise is -103 dBm;
The Default PCPICH Ec/No is -6 dB;
The Auto-Adaptive Background Noise Update Switch is OFF;
The Background Noise Update Continuance Time is 10 minutes;
The Equivalent User Number Threshold for Background Noise Update is 0;
The maximum HSUPA user number is 20;
The Dl HSUPA reserved factor is 20;
The Dl MBMS reserved factor is 20;

Ul HandOver Credit Reserved SF is SF16;


Dl HandOver Credit and Code Reserved SF is SF32.

hm parameters(ADD CELLCAC)

ontrol (CAC) algorithm parameters.


to set the CAC algorithm parameters based on the network management experience and algorithm analysis res
services: set the restrictions on the transmit power of different services to satisfy different coverage requiremen
cell: restrict the number of different services by setting different admission thresholds for conversational and o
(1): set different admission thresholds for conversational service, other services and the services in handover st
(2): reserve resources for UL/DL common channels so as to guarantee service transmission on the common cha
esponding to different QoS requirements, as follows:
ponds to real-time services. The QoS requirement of this class is determined by people's sensory. It has a relativ
ds to real-time streaming services, such as audio and video programs. It's unidirectionally transmitted and serve
ds to data services, such as terminal browsing. It has a strict BLER requirement, and the transmission delay shou
esponds to data services. It has a strict BLER requirement, but no transmission delay requirement. Typical servic

TU generally. In most cases, this parameter should not be changed.

L total power threshold] > [UL handover access threshold] > [UL threshold of Conv AMR service], [UL threshold
ld,UL threshold of Conv AMR service,UL threshold of Conv non_AMR service,UL threshold of other services) > [U
] >= [Ul LDR Credit SF reserved threshold];
L total power threshold] >= [DL handover access threshold] > [DL threshold of Conv AMR service], [DL thresho
old,DL threshold of Conv AMR service,DL threshold of Conv non_AMR service,DL threshold of other services) > [D
eserved SF] >= [Dl LDR Credit SF reserved threshold];
erved SF] >= [Cell LDR SF reserved threshold];
serve power];
H reserve SF].
UL Target LoadFactor].
threshold], [DL LDR trigger threshold], [UL OLC trigger threshold] and [DL OLC trigger threshold] are set in ADD

Descr
Description:Uniquely identifying a cell.
GUI value range:0~65535
Actual value range:{0~65535}
Unit:None

Default value:Recommended Value:None


Description:Defining the radio environment type of the cell, such as a typical town cell, urban cell, and
GUI value range:TU, RA, HT
Actual value range:TU, RA, HT
Unit:None
Default value:TU
Recommended Value:TU

Description:The percentage of the conversational AMR service threshold to the 100% uplink load. It is
admission. That is, when an AMR service is accessing, the RNC evalutates the measurement value of
the access of an AMR speech service, this service will be rejected. If the UL load of a cell will not be hi

The UL load factor thresholds include parameters of [UL threshold of Conv non_AMR service], [UL han
the proportion between the conversational service, handover user and other services in a specific cell
system load after admission may be over large, which impacts system stability and leads to system c
resources.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:75
Recommended Value:75

Description:The percentage of the conversational non-AMR service threshold to the 100% uplink load.
service admission. That is, when a non-AMR service is accessing, the RNC evalutates the measuremen
threshold after the access of a non-AMR speech service, this service will be rejected. If the UL load of

The UL load factor thresholds include parameters of [UL threshold of Conv non_AMR service], [UL han
the proportion between the conversational service, handover user and other services in a specific cell
the system load after admission may be over large, which impacts system stability and leads to syste
idle resources.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:75
Recommended Value:75

Description:The percentage of other service thresholds to the 100% uplink load. The services refer to
handover scenarios. It is applicable to algorithm 1 and algorithm 2. The parameter is used for controll
measurement value of the uplink load after the service is accessed. If the UL load of a cell is higher th
not be higher than this threshold, this service will be admitted.

The UL load factor thresholds include parameters of [UL threshold of Conv non_AMR service], [UL han
the proportion between the conversational service, handover user and other services in a specific cell
admission may be over large, which impacts system stability and leads to system congestion. If the v
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None

Default value:60
Recommended Value:60

Description:The percentage of the conversational AMR service threshold to the 100% downlink load. I
admission. That is, when an AMR service is accessing, the RNC evalutates the measurement value of
after the access of an AMR speech service, this service will be rejected. If the DL load of a cell will not

The DL load factor thresholds include parameters of [DL threshold of Conv non_AMR service], [DL han
limit the proportion between the conversational service, handover user and other services in a specifi
the system load after admission may be over large, which impacts system stability and leads to syste
idle resources and the failure to achieving network planning target.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:80
Recommended Value:80

Description:The percentage of the conversational non-AMR service threshold to the 100% downlink lo
service admission. That is, when a non-AMR service is accessing, the RNC evalutates the measuremen
threshold after the access of a non-AMR speech service, this service will be rejected. If the DL load of

The DL load factor thresholds include parameters of [DL threshold of Conv non_AMR service], [DL han
limit the proportion between the conversational service, handover user and other services in a specifi
high the system load after admission may be over large, which impacts system stability and leads to s
waste in idle resource and the failure to achieving the network planning target.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:80
Recommended Value:80

Description:The percentage of other service thresholds to the 100% downlink load. The services refer
handover scenarios. It is applicable to algorithm 1 and algorithm 2. The parameter is used for controll
measurement value of the downlink load after the service is accessed. If the DL load of a cell is highe
will not be higher than this threshold, this service will be admitted.

The DL load factor thresholds include parameters of [DL threshold of Conv non_AMR service], [DL han
limit the proportion between the conversational service, handover user and other services in a specifi
after admission may be over large, which impacts system stability and leads to system congestion. If
and the failure to achieving network planning target.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:75
Recommended Value:75

Description:The percentage of the handover service admission threshold to the 100% uplink load. It is
admission. That is, when a service is handing over to a cell, the RNC evalutates the measurement val
after the access, this service will be rejected. If the UL load of a cell will not be higher than this thresh

The UL load factor thresholds include parameters of [UL threshold of Conv non_AMR service], [UL han
the proportion between the non-handover service, handover user and other services in a specific cell,
access priority of the handover service. If the value is too high the system load after admission may b
the possibility of user rejects may increase, resulting in waste in idle resources.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:80
Recommended Value:80

Description:The percentage of the handover service admission threshold to the 100% downlink load. I
admission. That is, when a service is handing over to a cell, the RNC evalutates the measurement val
threshold after the access, this service will be rejected. If the DL load of a cell will not be higher than t

The DL load factor thresholds include parameters of [DL threshold of Conv non_AMR service], [DL han
limit the proportion between the non-handover service, handover user and other services in a specific
cell radius and cell maximum TX power. If the value is too high, the system load after admission may
the possibility of user rejects may increase, resulting in waste in idle resources.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:85
Recommended Value:85

Description:Admission threshold of total cell uplink power. This parameter is related to the target load
mechanism of the HSUPA. Therefore, the target load is added with margin, acting as the basis of this p
system stability and leads to system congestion. If the value is too low, the possibility of user rejects m
of the uplink schedule, the possibility of user rejects is great.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:83
Recommended Value:83

Description:Admission threshold of the total cell downlink power. If the value is too high, too many use
low, cell capacity will be wasted.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:90
Recommended Value:90
Description:The admission control decision is only for dedicated channels. For common channels, som

In the UL, according to the current load factor and the characteristics of the new call, the UL CAC algo
plus with the premeditated common channel UL load factor to get the predicted UL load factor. Then,
admitted; otherwise, rejected. If the value is too high, power resources are wasted, which impacts sys
case of insufficient resources.
GUI value range:0~100
Actual value range:0~1, step:0.01

Unit:None
Default value:0
Recommended Value:0

Description:Different admission policies are used for dedicated channel and common channel users. F
dedicated channel users, according to the current load factor and the characteristics of the new call, t
with the premeditated common channel DL load factor to get the predicted DL load factor. Then, comp
admitted; otherwise, rejected.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:0
Recommended Value:0

Description:When the algorithm 2 is used, this parameter defines the total equivalent user numbers c
and actual condition of the network. If the value is too high, the system load after admission may be o
possibility of user rejects may increase, resulting in waste in idle resources.
GUI value range:1~200
Actual value range:1~200
Unit:None
Default value:80
Recommended Value:80

Description:When the algorithm 2 is used, this parameter defines the total equivalent user number co
and actual condition of the network. If the value is too high, the system load after admission may be o
possibility of user rejects may increase, resulting in waste in idle resources.
GUI value range:1~200
Actual value range:1~200
Unit:None
Default value:80
Recommended Value:80

Description:Threshold of all the HSUPA user PBR whose schedule priority is lower than that of users to
which impacts access success rate. If the value is too low, too many HSUPA schedule users may be ad
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:per cent
Default value:100
Recommended Value:100

Description:Threshold of all the HSUPA user PBR whose schedule priority is the same as that of users t
which impacts access success rate. If the value is too low, too many HSUPA schedule users may be ad
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:per cent
Default value:100
Recommended Value:100

Description:Threshold of all the HSUPA user PBR whose schedule priority is higher than that of users t
which impacts access success rate. If the value is too low, too many HSUPA schedule users may be ad
congestionRecommended.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:per cent
Default value:100
Recommended Value:100

Description:If the HS-DPCCH carries ACK/NACK, the system will not perform CAC. If the HS-DPCCH carr
HS-DPCCH carrying ACK/NACK. The corresponding threshold is the uplink limit capacity multiplied by t
increases, leading to waste in uplink resources. If the value is too low, the uplink resources is insufficie
the value can be set to a low level, representing the loose admission rule.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:per cent
Default value:0
Recommended Value:0

Description:Average throughput admission threshold of the HSDPA streaming service. If the sum of PB
the HSDPA streaming service multiplied by the sum of GBR of all the accessed streaming users, it indi
not allowed. Otherwise, the QoS can be satisfied and new HSDPA streaming services are allowed. If th
the service quality of the HSDPA streaming service but also may lead to HSDPA capacity waste. If the
HSDPA streaming services but QoS of the HSDPA streaming service cannot be guaranteed.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:per cent
Default value:70
Recommended Value:70

Description:Average throughput admission threshold of the HSDPA best effort traffic. If the sum of PBR
HSDPA BE service multiplied by the sum of GBR of all the accessed HSDPA BE users, it indicates that t
Otherwise, the QoS can be satisfied and new HSDPA BE services are allowed. If the value is too high, a
HSDPA BE service but also may lead to HSDPA capacity waste. If the value is too low, admission requir
service cannot be guaranteed.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:per cent
Default value:30
Recommended Value:30

Description:Maximum number of users supported by the HSDPA channel. The user in this parameter r
HSDPA channel. Maximum HSDPA user number cannot exceed the HSDPA capability of the NodeB prod
power and code resources. If the value is too low, the cell HSDPA capacity may be reduces, leading to
GUI value range:0~100
Actual value range:0~100
Unit:None

Default value:64
Recommended Value:64

Description:Maximum UL transmit power for conversational service in a specific cell. It is based on the
the value of this parameter is, the wider the coverage of the corresponding services will be. When the
become unbalanced. If the values of these parameters are too small, the uplink coverage will probabl
"Maximum allowed UL TX power", refer to the 3GPP TS 25.331.
GUI value range:-50~33
Actual value range:-50~33
Unit:dBm
Default value:24
Recommended Value:24

Description:Maximum UL transmit power for the streaming service in a specific cell. It is based on the
value of this parameter is, the wider the coverage of the corresponding services will be. When the dow
unbalanced. If the values of these parameters are too small, the uplink coverage will probably be sma
allowed UL TX power", refer to the 3GPP TS 25.331.
GUI value range:-50~33
Actual value range:-50~33
Unit:dBm
Default value:24
Recommended Value:24

Description:The maximum UL transmit power for the interactive service in a specific cell. It is based o
the value of this parameter is, the wider the coverage of the corresponding services will be. When the
become unbalanced. If the values of these parameters are too small, the uplink coverage will probabl
"Maximum allowed UL TX power", refer to the 3GPP TS 25.331.
GUI value range:-50~33
Actual value range:-50~33
Unit:dBm
Default value:24
Recommended Value:24

Description:The maximum UL transmit power for background service in a specific cell. It is based on t
the value of this parameter is, the wider the coverage of the corresponding services will be. When the
become unbalanced. If the values of these parameters are too small, the uplink coverage will probabl
"Maximum allowed UL TX power", refer to the 3GPP TS 25.331.
GUI value range:-50~33
Actual value range:-50~33
Unit:dBm
Default value:24
Recommended Value:24

Description:If [Auto-Adaptive Background Noise Update Switch] is set to OFF, it is used to set backgro
background noise is restricted by this parameter and [PARA]BgnAbnormalThd[/PARA]. For detailed info
GUI value range:0~621
Actual value range:-112~-50,step:0.1
Unit:dBm
Default value:61
Recommended Value:61

Description:When the RNC is performing downlink open power control, it evaluates link consumption a
some cases, the UE may not report the signal intensity. In this situation, the RNC uses this parameter
GUI value range:-30~30
Actual value range:-30~30
Unit:dB
Default value:-13
Recommended Value:-13
Description:When the parameter is 'OFF', the auto-adaptive background noise update algorithm is sw
GUI value range:OFF, ON
Actual value range:OFF, ON
Unit:None
Default value:ON
Recommended Value:ON

Description:Only when the measured background noise's duration reaches this parameter, the output
and the current value is replaced with the new one. At the same time, the auto-adaptive status should
GUI value range:1~6000
Actual value range:1~6000
Unit:s
Default value:120
Recommended Value:120

Description:When the number of uplink equivalent users is not larger than this parameter, the RTWP c
adaptive background noise update filter; otherwise, the RTWP could not be regarded as background n
reset.
GUI value range:0~10
Actual value range:0~10
Unit:None
Default value:0
Recommended Value:0

Description:Maximum number of users supported by the HSUPA channel.The user in this parameter re
HSUPA channel. Maximum HSUPA user number cannot exceed the HSUPA capacity.
GUI value range:0~100
Actual value range:0~100
Unit:None
Default value:20
Recommended Value:20

Description:Reserved DL power factor for HSUPA user. The higher the value is, the more resources res
user quality may be impacted.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:0
Recommended Value:0
Description:Reserved DL power factor for MBMS service.
GUI value range:0~100

Actual value range:0~1, step:0.01


Unit:None
Default value:0
Recommended Value:0

Description:Available guarantee power of all the MTCHs. This parameter is a protection for the MBMS
avoided. This is because the MBMS PTM bearing serves multiple users at the same time. The value sh
bearing and too little capacity is left for the non-MBMS services.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:20
Recommended Value:20

Description:Available guarantee codes of all the MTCHs. This parameter is a protection for the MBMS P
avoided. This is because the MBMS PTM bearing serves multiple users at the same time. The value sh
bearing and too little capacity is left for the non-MBMS services.
GUI value range:0~63
Actual value range:0~63
Unit:None
Default value:16
Recommended Value:16

Description:Maximum power limit of all the MTCHs. This parameter is a limit to the maximum bearing
bearing should be avoided. This is because the MBMS PTM bearing serves multiple users at the same
MBMS PTM bearing and too little capacity is left for the non-MBMS services.
GUI value range:0~100
Actual value range:0~1, step:0.01
Unit:None
Default value:60
Recommended Value:60

Description:Maximum code limit of all the MTCHs. This parameter is a limit to the maximum bearing o
should be avoided. This is because the MBMS PTM bearing serves multiple users at the same time. Th
PTM bearing and too little capacity is left for the non-MBMS services.
GUI value range:0~63
Actual value range:0~63
Unit:None
Default value:40
Recommended Value:40

Description:Uplink Credit Reserved by Spread Factor for HandOver. SFOFF means that none of them a
of a new service, the service will be rejected. If the value is too high, the credit resource reserved for
and performance of handover UEs cannot be guaranteed. If the value is too low, the possibility of reje
GUI value range:SF4(SF4), SF8(SF8), SF16(SF16), SF32(SF32), SF64(SF64), SF128(SF128), SF256(SF25
Actual value range:SF4,SF8,SF16,SF32,SF64,SF128,SF256,SFOFF
Unit:None
Default value:SF16
Recommended Value:SF16

Description:Some cell resources can be reserved for handover UEs to guarantee handover success rat
code and CE resources reserved for handover. SFOFF refers to that no resources is reserved. SF32 refe
backer position the value is in {SF4,SF8,SF16,SF32,SF64,SF128,SF256,SFOFF}, the less code and cred
and performance of UEs cannot be guaranteed. The more frontal position the value is, the more the p
GUI value range:SF4(SF4), SF8(SF8), SF16(SF16), SF32(SF32), SF64(SF64), SF128(SF128), SF256(SF25
Actual value range:SF4,SF8,SF16,SF32,SF64,SF128,SF256,SFOFF
Unit:None
Default value:SF32
Recommended Value:SF32

Description:(1) This parameter, along with the [Algorithm stop time], is used to limit the validation tim
[Algorithm start time], and the background noise automatic updata algorithm is enabled, then the alg
other periods, the algorithm fails. If [Algorithm stop time] is less than [Algorithm start time], and the b
period of [Algorithm stop time] each day to [Algorithm start time] of the next day. In other periods, th
(2) Input format: HH&MM&SS.
GUI value range:hour, min, sec
Actual value range:hour{0~23}, min{0~59}, sec{0~59}
Unit:None
Default value:Recommended Value:01&00&00

Description:(1) This parameter, along with the [Algorithm start time], is used to limit the validation tim
[Algorithm start time], and the background noise automatic updata algorithm is enabled, then the alg
other periods, the algorithm fails. If [Algorithm stop time] is less than [Algorithm start time], and the b
period of [Algorithm stop time] each day to [Algorithm start time] of the next day. In other periods, th
(2) Input format: HH&MM&SS.
GUI value range:hour, min, sec
Actual value range:hour{0~23}, min{0~59}, sec{0~59}
Unit:None
Default value:Recommended Value:06&00&00
Description:The difference of RTWP that trigger the update of background noise. If the difference is lar
GUI value range:1~100
Actual value range:0.1~10, step:0.1
Unit:dBm
Default value:5
Recommended Value:5

Description:This parameter is applied when [PARA]BGNSwitch[/PARA] is set to ON. (1) If the difference
RTWP threshold, the background noise will not be updated. (2) If the difference of new background no
updated.
GUI value range:1~400
Actual value range:0.1~40, step:0.1
Unit:dB
Default value:100

Recommended Value:100
Description:Maximum number of users supported by the EFACH channel.
GUI value range:0~48
Actual value range:0~48
Unit:None
Default value:48
Recommended Value:48

pe=TU, NonorthoFactor=400, UlNonCtrlThdForAMR=75, DLConvAMRThd=80, DLConvNonAMRThd=80, DLOtherT

ameters of cell 1 are set as follows:

ice is 0.75;
service is 0.75;

ice is 80%;
service is 80%;

ved coefficient is 0%;

f
f
f
f

conversational service is 24dBm;


streaming service is 24dBm;
interactive service is 24dBm;
background service is 24dBm;

se Update Switch is OFF;


tinuance Time is 10 minutes;
hold for Background Noise Update is 0;

rved SF is SF32.

o consideration together with the capacity specification.

R speech and video phone.


quential relation should be ensured. Typical service: Video on demand.

LDR Credit SF reserved threshold] and [Cell LDR SF reserved threshold] are set in ADD CELLLDR and MOD CELL

talEqUserNum=80,DlTotalEqUserNum=80, UlHsDpcchRsvdFactor=0, HsdpaStrmPBRThd=70, HsdpaBePBRThd=3

LLDR and MOD CELLLDR, and they can be listed by LST CELLLDR. The parameters of [UL Target LoadFactor] is se

0, HsdpaBePBRThd=30, MaxHsdpaUserNum=64, MaxUlTxPowerforConv=24, MaxUlTxPowerforStr=24, MaxUlTxP

rget LoadFactor] is set in MOD CELLHSUPA.

forStr=24, MaxUlTxPowerforInt=24, MaxUlTxPowerforBac=24, BackgroundNoise=71, DefPcpichEcNo=-13, BGN

cpichEcNo=-13, BGNSwitch=OFF, BGNAdjustTimeLen=10, BGNEqUserNumThd=0, ShoInitPwrPo=15, MaxHsupaU

wrPo=15, MaxHsupaUserNum=20, DlHSUPARsvdFactor=20, DlMBMSRsvdFactor=20, UlHoCeResvSf=SF16, DlHoC

eResvSf=SF16, DlHoCeCodeResvSf=SF32;

INDEX

Set UE Timers and Constants in Idle Mode(SET IDLEMODETIMER)


Function
Note
Parameter
Example
Function

Set UE timers and constants in idle mode.


Note

None.
Parameter

ID

T300

Name

Timer
300

Constant
N300 300

T312

Timer
312

Constant
N312 312
Example

Modify the Constant 300 in idle mode. The maximum number ofretransmissions of RRC CONNECTION
SET IDLEMODETIMER: N300=4;
After the above operation, N300 is modified as 4.

Timers and Constants in Idle Mode(SET IDLEMODETIMER)

imers and constants in idle mode.

Description
Value range: D100, D200, D400, D600, D800, D1000, D1200, D1400, D1600, D1800, D2000, D3000, D
D6000, D8000.

Physical value range: 100, 200, 400, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 600
Physical unit: ms.

Content: T300 is started when UE sends the RRC CONNECTION REQUEST message. It is stopped when
receives the RRC CONNECTION SETUP message. RRC CONNECTION REQUEST will be resent upon the e
the timer if V300 is lower than or equal to N300, else enter idle mode.
Recommended value: D2000.
Value range: 0~7.
Physical unit: None.
Content: Maximum number of retransmissions of the RRC CONNECTION REQUEST message.
Recommended value: 3.
Physical unit: s.

Content: T312 is started when UE starts to establish a DCH, and stopped when UE detects consecutiv
"in sync" indications from L1. It indicates physical channel setup failure upon the expiry of the timer.
Recommended value: 6.
Value range: D1, D2, D4, D10, D20, D50, D100, D200, D400, D600, D800, D1000.
Physical value range: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, 1000.
Physical unit: None.
Content: Maximum number of successive "in sync" indications received from L1.
Recommended value: D1.

he Constant 300 in idle mode. The maximum number ofretransmissions of RRC CONNECTION REQUEST is modifi
EMODETIMER: N300=4;
e above operation, N300 is modified as 4.

INDEX

Set UE Timers and Constants in Connected Mode(SET CONNMODETIMER)


Function
Note
Parameter
Example
Function

Set UE timers and constants in connected mode.


Note

It is demanded that the time value of T314 and T315 shall be both equal to 0 or both greater than T30
According to 25331 CR 1990, T317 will never expire, all values are mapped to infinity.
Parameter

ID

Name

T302

Timer 302

N302

Constant
302

T304

Timer 304

N304

Constant
304

N304

Constant
304

T305

Timer 305

T307

Timer 307

T308

Timer 308

N308

Constant
308

T309

Timer 309

T312

Timer 312

N312

Constant
312

T313

Timer 313

N313

Constant
313

T314

Timer 314

T315

Timer 315

N315

Constant
315

T316

Timer 316

T316

Timer 316

T317

Timer 317

Example

Set the constant 315 used by UE in connected mode as 50.


SET CONNMODETIMER: N315 = D50;
After the above operation, N315 is set as 50.

mers and Constants in Connected Mode(SET CONNMODETIMER)

s and constants in connected mode.

ed that the time value of T314 and T315 shall be both equal to 0 or both greater than T302*N302.
25331 CR 1990, T317 will never expire, all values are mapped to infinity.

Description
Value range: D100, D200, D400, D600, D800, D1000, D1200, D1400, D1600, D1800, D2000, D3000, D
D6000, D8000.

Physical value range: 100, 200, 400, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 600
Physical unit: ms.

Content: T302 is started after the UE transmits the CELL UPDATE/URA UPDATE message and stopped a
UE receives the CELL UPDATE CONFIRM/URA UPDATE CONFIRM message. CELL UPDATE/URA UPDATE w
resent upon the expiry of the timer if V302 less than or equal to N302; otherwise, the UE will enter idl
Protocol default value is 4000.
Recommended value: D2000.
Value range: 0~7.

Content: Maximum number of retransmissions of CELL UPDATE/URA UPDATE.Protocol default value is 3


Recommended value: 3.
Physical value range: 100, 200, 400, 1000, 2000.
Physical unit: ms.

Content: T304 is started after the UE sends the UE CAPABILITY INFORMATION message and stopped a
UE receives the UE CAPABILITY INFORMATION CONFIRM message. UE CAPABILITY INFORMATION will be
upon the expiry of the timer if V304 less than or equal N304; otherwise the cell update procedure will
initiated. Protocol default value is 2000.
Recommended value: D2000.
Value range: 0~7.

Content: Maximum number of retransmissions of UE CAPABILITY INFORMATION. Protocol default value

Recommended value: 3.
Value range: INFINITY, D5, D10, D30, D60, D120, D360, D720.
Physical value range: Infinity, 5, 10, 30, 60, 120, 360, 720.
Physical unit: min.

Content: T305 is started after the UE receives CELL UPDATE CONFIRM/URA UPDATE CONFIRM in CELL_
URA_PCH or CELL_PCH state. It is stopped after the UE enters another state. CELL UPDATE will be tran
upon the expiry of this timer if T307 is not activated and the UE detects "in service area"; otherwise, T
be started. Protocol default value is 30. "Infinity" means the cell will not be updated.
Recommended value: D10.
Value range: D5, D10, D15, D20, D30, D40, D50.
Physical value range: 5, 10, 15, 20, 30, 40, 50.
Physical unit: s.

Content: T307 is started after T305 has expired and the UE detects "out of service area". It is stopped
UE detects "in service area". The UE will enter idle mode upon expiry.Protocol default value is 30.
Value range: D40, D80, D160, D320.
Physical value range: 40, 80, 160, 320.
Physical unit: ms.

Content: T308 is started after the UE transmits RRC CONNECTION RELEASE COMPLETE. This message
sent upon the expiry of the Timer if V308 less than or equal to N308, otherwise, the UE will enter idle
Protocol default value is 160.
Recommended value: D40.
Value range: 1~8.
Content: Maximum number of retransmission of RRC CONNECTION RELEASE COMPLETE.
Recommended value: 1.
Value range: 1~8.
Physical unit: s.

Content: T309 is started after the UE is reselected to a cell belonging to another radio access system
connected mode, or the CELL CHANGE ORDER FROM UTRAN message is received. It is stopped after t
successfully connected in the new cell. The UE will continue the connection to UTRAN upon expiry. Pro
default value is 5.
Recommended value: 5.
Value range: 1 ~ 15.
Physical unit: s.

Content: T312 is started after the UE starts to establish a DCH and stopped when the UE detects cons
N312 "in sync" indications from L1. It indicates physical channel setup failure upon the expiry of the t
Protocol default value is 1.
Recommended value: 6.
Value range: D1, D2, D4, D10, D20, D50, D100, D200, D400, D600, D800, D1000.
Physical value range: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, 1000.

Content: Maximum number of successive "in sync" indications received from L1. Protocol default valu
Recommended value: D1.
Value range: 0~15.

Physical unit: s.

Content: T313 is started after the UE detects consecutive N313 "out of sync" indications from L1. T31
stopped after the UE detects consecutive N315 "in sync" indications from L1.It indicates Radio Link (R
upon expiry. Protocol default value is 3.
Recommended value: 3.
Value range: D1, D2, D4, D10, D20, D50, D100, D200.
Physical value range: 1, 2, 4, 10, 20, 50, 100, 200.

Content: Maximum number of successive "out of sync" indications received from L1. Protocol default v
20.
Recommended value: D50.
Value range: D0, D2, D4, D6, D8, D12, D16, D20.
Physical value range: 0, 2, 4, 6, 8, 12, 16, 20.
Physical unit: s.

Content: T314 is started when the criteria for radio link failure are fulfilled and only radio bearers (RBs
associated with T314 exist.T314 is stopped after the Cell Update procedure has been completed. Prot
default value is 12.

In case of the RL failure when the UE is in CELL_DCH state, If the RL cannot be successfully reconfigur
CELL UPDATE CONFIRM before the expiry of the corresponding T314 (or T315), CELL UPDATE will be re
RL reconfiguration (this operation relates to T302 and N302). T314 should be set greater than T302*N
case of the expiry of T314, the corresponding service RBs will be removed.
Recommended value: D20.
Value range: D0, D10, D30, D60, D180, D600, D1200, D1800.
Physical value range: 0, 10, 30, 60, 180, 600, 1200, 1800.
Physical unit: s.

Content: T315 is started when the criteria for radio link failure are fulfilled, and only the radio bearer a
with T315 exists.T315 is stopped after the Cell Update procedure has been completed. Protocol defau
180.

In case of the RL failure when the UE is in CELL_DCH state, T315 (or T314) is started and CELL UPDATE
If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corre
T315 (or T314), CELL UPDATE will be resent for RL reconfiguration (this operation relates to T302 and
T315 should be set greater than T302*N302. In case of the expiry of T315, the corresponding service
be removed.
Recommended value: D30.
Value range: D1, D2, D4, D10, D20, D50, D100, D200, D400, D600, D800, D1000.
Physical value range: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, 1000.
Physical unit: NONE.

Content: Maximum number of successive "in sync" indications received from L1 when T313 is activate
Protocol default value is 1.
Recommended value: D1.
Value range: D0, D10, D20, D30, D40, D50, INFINITY.
Physical value range: 0, 10, 20, 30, 40, 50, infinity.
Physical unit: s.

Content: T316 is started after the UE detects "out of service area" in URA_PCH or CELL_PCH state.T31
stopped after the UE detects "in service area".The cell update procedure will be initiated upon the exp
timer if "in service area" is detected; otherwise, T317 will be started. The UE will enter CELL_FACH sta
initiate cell update procedure when the UE detects "in service area". Protocol default value is 30.
Recommended value: D30.
Value range: D0, D10, D30, D60, D180, D600, D1200, D1800.
Physical value range: infinity, infinity, infinity, infinity, infinity, infinity, infinity, infinity.
Physical unit: s.

Content: T317 is started after the T316 expires or the UE in CELL_FACH state detects "out of service a
According to 25331 CR 1990, T317 will never expire, all values are mapped to infinity. Protocol default
infinity.
Recommended value: D0.

ant 315 used by UE in connected mode as 50.


ODETIMER: N315 = D50;
ve operation, N315 is set as 50.

INDEX
Parameter

ID

Name

INTERRATREPORTMODE

Inter-RAT report mode

2D2FMEASQUANTITY

2D2F Measure
Quantity

2D2FFILTERCOEF

2D2F filter coeff

INTERRATFILTERCOEF

Inter-RAT filter coeff

WEIGHTFORUSEDFREQ

Weight for Used


frequency

INTERRATPERIODREPORTI Inter-RAT period report


NTERVAL
interval

HYSTFOR2D

2D hysteresis

HYSTFOR2F

2F hysteresis

HYSTFOR3A

3A hysteresis

HYSTFORINTERRAT

Inter-RAT hysteresis

TRIGTIME2D

2D event trigger delay


time

TRIGTIME2F

2F event trigger delay


time

TRIGTIME3A

3A event trigger delay


time

TIMETOTRIGFORNONVERI Time to trigger for


FY
non-verified GSM cell

TIMETOTRIGFORVERIFY

Time to trigger for


verified GSM cell

BSICVERIFY

BSIC verify switch

BSICVERIFY

BSIC verify switch

INTERRATCSTHD2DECN0

Inter-RAT CS measure
start Ec/No THD

INTERRATCSTHD2FECN0

Inter-RAT CS measure
stop Ec/No THD

INTERRATPSTHD2DECN0

Inter-RAT PS measure
start Ec/No THD

INTERRATPSTHD2FECN0

Inter-RAT PS measure
stop Ec/No THD

INTERRATCSTHD2DRSCP

Inter-RAT CS measure
start RSCP THD

INTERRATCSTHD2FRSCP

Inter-RAT CS measure
stop RSCP THD

INTERRATPSTHD2DRSCP

Inter-RAT PS measure
start RSCP THD

INTERRATPSTHD2FRSCP

Inter-RAT PS measure
stop RSCP THD

INTERRATCOVHOCSTHD

Inter-RAT CS handover
decision THD

INTERRATCOVHOPSTHD

Inter-RAT PS handover
decision THD

Inter-RAT CS Used
IRHOUSEDFREQCSTHDEC frequency trigger
N0
Ec/No THD

Inter-RAT PS Used
IRHOUSEDFREQPSTHDEC frequency trigger
N0
Ec/No THD

Inter-RAT PS Used
IRHOUSEDFREQPSTHDEC frequency trigger
N0
Ec/No THD

Inter-RAT CS Used
IRHOUSEDFREQCSTHDRS frequency trigger
CP
RSCP THD

Inter-RAT PS Used
IRHOUSEDFREQPSTHDRS frequency trigger
CP
RSCP THD

Inter-RAT handover
PENALTYTIMEFORINTERRA failure penalty timer
THO
length

INTERRATMEASTIME

Inter-RAT measure
timer length

Description
Value range: Periodical_ reporting, Event_trigger.
Physical unit: None.
Content: Inter-RAT measurement reporting mode. "Periodical_reporting" represents periodical reporting mode.
"Event_trigger" represents event-triggered reporting mode.
Recommended value: Periodical_reporting.
Value range: CPICH_Ec/No, CPICH_RSCP.
Physical unit: None.
Content: Measurement value used in coverage-based inter-RAT measurement in event (2D/2F)Ctriggered or
periodical reporting mode.
Recommended value: CPICH_RSCP.
Value range: D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D11, D13, D15, D17, D19.
Physical value range: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19.
Physical unit: None.
Content: L3 filtering coefficient for event 2D/2F measurement. The greater this parameter is, the greater the
smoothing effect and the higher the anti fast fading capability, but the lower the signal change tracing
capability.
Recommended value: D3.
Value range: D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D11, D13, D15, D17, D19.
Physical value range: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19.
Physical unit: None.
Content: L3 filtering coefficient for inter-RAT measurement. The greater this parameter is, the greater the
smoothing effect and the higher the anti fast fading capability, but the lower the signal change tracing
capability.
Recommended value: D3.
Value range: 0~20.
Physical value range: 0~2; step: 0.1.
Physical unit: None.
Content: Weight used for computing frequency general quality. The more this parameter is, the higher the
calculated general quality of an active set. When this parameter is 0, the general quality of the active set is
the quality of the best cell in it. This parameter is used for event 3A evaluation.
Recommended value: 0.

Value range: NON_PERIODIC_REPORT,D250, D500, D1000, D2000, D3000, D4000, D6000, D8000, D12000,
D16000, D20000, D24000, D28000, D32000, D64000.

Physical unit: ms.


Content: Inter-RAT measurement reporting interval.
Recommended value: D1000.
Value range: 0~29.
Physical value range: 0~14.5; step: 0.5.
Physical unit: dB.
Content: Event 2D trigger hysteresis. This parameter value is related to the slow fading characteristic. The
greater this parameter is, the less the ping-pong effect and misjudgment that can be caused. However, in this
case, the event cannot be triggered in time.
Recommended value: 6.
Value range: 0~29.
Physical value range: 0~14.5; step: 0.5.
Physical unit: dB.
Content: Event 2F trigger hysteresis. This parameter value is related to the slow fading characteristic. The
greater this parameter is, the less the ping-pong effect and misjudgment that can be caused. However, in this
case, the event cannot be triggered in time.
Recommended value: 6.
Value range: 0~15.
Physical value range: 0~7.5; step: 0.5.
Physical unit: dB.
Content: Event 3A trigger hysteresis. This parameter value is related to the slow fading characteristic. The
greater this parameter is, the less the ping-pong effect and misjudgment that can be caused. However, in this
case, the event cannot be triggered in time.
Recommended value: 0.
Value range: 0~15.
Physical value range: 0~7.5; step: 0.5.
Physical unit: dB.
Content: Determining whether to trigger inter-RAT handover decision together with quality threshold. The
smaller the shadow fading is, the smaller the parameter value should be.
Recommended value: 4.
Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560,
D5000.
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000.

Physical unit: ms.


Content: Event 2D trigger delay time. This parameter value is related to the slow fading characteristic. The
greater this parameter is, the smaller the misjudgment probability, but the lower the speed of event response
to measured signal changes.
Recommended value: D640.
Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560,
D5000.
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000.
Physical unit: ms.
Content: Event 2F trigger delay time. This parameter value is related to the slow fading characteristic. The
greater this parameter is, the smaller the misjudgment probability, but the lower the speed of event response
to measured signal changes.
Recommended value: D640.
Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640, D1280, D2560,
D5000.
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000.
Physical unit: ms.
Content: Event 3A trigger delay time. This parameter value is related to the slow fading characteristic. The
greater this parameter is, the smaller the misjudgment probability, but the lower the speed of event response
to measured signal changes.
Recommended value: D640.
Value range: 0~64000, 65535.
Physical unit: ms.
Content: Delay time for triggering a GSM cell unacknowledged by BSIC. In the period specified by this
parameter, if the signal quality of an adjacent GSM cell meets the requirement for inter-RAT handover and this
cell is unacknowledged, the network will start inter-RAT handover. The value 65535 means that the RNC will
not hand over to an unacknowledged GSM cell.
Recommended value: 65535.
Value range: 0~64000.
Physical unit: ms.
Content: Delay time for triggering a GSM cell acknowledged by BSIC. In the period specified by this parameter,
if the signal quality of an adjacent GSM cell meets the requirement for inter-RAT handover and this cell is
acknowledged, the network will start inter-RAT handover.
Recommended value: 0.
Value range: Required, Not Required.
Physical unit: None.
Content: Controlling whether to report a detected cell. The value "Required" means that a detected GSM cell
will be reported only after its BSIC is decoded correctly. The value "Not Required" means that a detected GSM
cell will be reported whether its BSIC is decoded or not as long as it meets reporting conditions.

Recommended value: Required.


Value range: C24~0.
Physical unit: dB.
Content: If the CS service uses Ec/No as measurement item, when the measurement value is lower than this
threshold, the UE reports event 2D; the RNC sends a signalling to enable compressed mode and start inter-RAT
measurement.
Recommended value: C16.
Value range: C24~0.
Physical unit: dB.
Content: If the CS service uses Ec/No as measurement item, when the measurement value is higher than this
threshold, the UE reports event 2F; the RNC sends a signalling to disable compressed mode and stop inter-RAT
measurement.
Recommended value: C14.
Value range: C24~0.
Physical
Content: unit:
If thedB.
PS service uses Ec/No as measurement item, when the measurement value is lower than this
threshold, the UE reports event 2D; the RNC sends a signalling to enable compressed mode and start inter-RAT
measurement.
Recommended value: C16.
Value range: C24~0.
Physical unit: dB.
Content: If the PS service uses Ec/No as measurement item, when the measurement value is higher than this
threshold, the UE reports event 2F; the RNC sends a signalling to disable compressed mode and stop inter-RAT
measurement.
Recommended value: C14.
Value range: C115 to C25.
Physical unit: dBm.
Content: If the CS service uses RSCP as measurement item, when the measurement value is lower than this
threshold, the UE reports event 2D; the RNC sends a signalling to enable compressed mode and start inter-RAT
measurement.
Recommended value: C95.
Value range: C115 to C25.
Physical unit: dBm.
Content: If the CS service uses RSCP as measurement item, when the measurement value is higher than this
threshold, the UE reports event 2F; the RNC sends a signalling to disable compressed mode and stop inter-RAT
measurement.
Recommended value: C90.
Value range: C115 to C25.

Physical unit: dBm.


Content: If the PS service uses RSCP as measurement item, when the measurement value is lower than this
threshold, the UE reports event 2D; the RNC sends a signalling to enable compressed mode and start inter-RAT
measurement.
Recommended value: C95.
Value range: C115 to C25.
Physical unit: dBm.
Content: If the PS service uses RSCP as measurement item, when the measurement value is higher than this
threshold, the UE reports event 2F; the RNC sends a signalling to disable compressed mode and stop inter-RAT
measurement.
Recommended value: C90.
Value range: 0~63.
Physical value range: C110 to C48 (1: C110; 2: C109; ...; 63: C48).
Physical unit: dBm.
Content: This parameter indicates the requirement of CS service inter-RAT handover for the quality of inter-RAT
cells. If the event-triggered reporting mode is adopted, event 3A might be triggered when the quality of the
target frequency is higher than this threshold. If the periodical reporting mode is adopted, this parameter is
used for coverage-based inter-RAT handover evaluation at the RNC side. The value 0 means the physical value
is smaller than C110 dBm.
Recommended value: 21.
Value range: 0~63.
Physical value range: C110 to C48 (1: C110; 2: C109; ...; 63: C48).
Physical unit: dBm.
Content: This parameter indicates the requirement of PS service inter-RAT handover for the quality of inter-RAT
cells. If the event-triggered reporting mode is adopted, event 3A might be triggered when the quality of the
target frequency is higher than this threshold. If the periodical reporting mode is adopted, this parameter is
used for coverage-based inter-RAT handover evaluation at the RNC side. The value 0 means the physical value
is smaller than C110 dBm.
Recommended value: 21.
Value range: C24~0.
Physical unit: dB.
Content: If CS service inter-RAT handover uses the event-triggered reporting mode, event 3A might be
triggered only the Ec/No value of the used frequency is lower than this threshold. (Event 3A can be triggered
only when the two necessary conditions can be met at the same time.)
Recommended value: C16.
Value range: C24~0.
Physical unit: dB.

Content: If PS service inter-RAT handover uses the event-triggered reporting mode, event 3A might be
triggered only the Ec/No value of the used frequency is lower than this threshold. (Event 3A can be triggered
only when the two necessary conditions can be met at the same time.)
Recommended value: C16.
Value range: -115~-25.
Physical unit: dBm.
Content: If CS service inter-RAT handover uses the event-triggered reporting mode, event 3A might be
triggered only the RSCP value of the used frequency is lower than this threshold. (Event 3A can be triggered
only when the two necessary conditions can be met at the same time.)
Recommended value: C95.
Value range: -115~-25.
Physical unit: dBm.
Content: If PS service inter-RAT handover uses the event-triggered reporting mode, event 3A might be
triggered only the RSCP value of the used frequency is lower than this threshold. (Event 3A can be triggered
only when the two necessary conditions can be met at the same time.)
Recommended value: C95.
Value range: 0~65535.
Physical unit: s.
Content: If the inter-RAT handover to a GSM cell fails, the possible reason is that this cell is overloaded.
Therefore, in the period specified by this parameter, the system will not send the inter-RAT handover request
to this cell.
Recommended value: 30.
Value range: 0~512.
Physical unit: s.
Content: If no inter-RAT handover occurs upon expiry of the inter-RAT measurement timer, the system stops
inter-RAT measurement and disables the compressed mode if enabled. If this parameter is 0, the system will
not start the inter-RAT measurement timer.
Recommended value: 60.

3RU03

Periodical_r
eporting

CPICH_RSC
P

D3

D3

D1000

D640

D640

D640

65535

Required

-16

-14

-16

-14

-95

-90

-95

-90

21
( 90dBm)

21

16

16

95

95

30

60

INDEX

Add Cell HSDPA Parameters(ADD CELLHSDPA)


Function

Add high speed downlink packet access (HSDPA) parameters for a cell.
Note

The cell must have been configured.


Parameter

ID
CELLID

ALLOCCODEMODE

HSPDSCHCODENUM

HSPDSCHMAXCODENUM

HSPDSCHMINCODENUM

Name
Cell ID

Allocate
Code
Mode
Code
Number
for HSPDSCH
Code Max
Number
for HSPDSCH
Code Min
Number
for HSPDSCH

HSSCCHCODENUM

Reserved
SF
threshold
Code
Number
for HSSCCH

HSDPAPOWER

HS-PDSCH
And HSSCCH
Power

REVSFTHD

HSDPAPOWER

HS-PDSCH
And HSSCCH
Power

HSPDSCHMPOCONSTENUM

HS-PDSCH
MPO
Constant

Example

Add HSDPA parameters for cell 1 as follows:


1. Allocate Code Mode is Manual.
2. Number of HS_PDSCH codes is 5.
3. Number of HS_SCCH codes is 4.
4. Max sum of HS_PDSCH power and HS_SCCH power is 38 dBm.
5. HS_PDSCH MPO Constant is 2.5dB.
ADD CELLHSDPA: CELLID=1,AllocCodeModeManual,HSPDSCHCODENUM=5, HSSCCHCODENUM=4,

ADD CELLHSDPA)

cess (HSDPA) parameters for a cell.

Description
Value range: 0~65535.
Content: Uniquely identifying a cell.
Value range: Manual,Automatic.
Content: Choose the mode of allocating HsPdsch codes.There are two modes:
Manual, Automatic. If Manual is chosen, allocating HsPdsch code number the
equal of configured HsPdsch code number. If Automatic is chosen, allocating
HsPdsch code number between configured HsPdsch Maximum code number
and HsPdsch Minimum code number.
Recommended value: Manual.
Value range: 1~15.
Content: Number of HS-PDSCH codes.
Recommended value: 5.
Value range: 1~15.
Content: Maxmim Number of HS-PDSCH codes.
Recommended value: 10.
Value range: 1~15.
Content: Minimum Number of HS-PDSCH codes.
Recommended value: 5.
Content: Reserved SF.This parameter is used to
decide whether increase HsPdsch code number or not.
If in cell's code tree there is at least one code can be
reserved and this code's SF is equal to or less than this
parameter ,try to increase HsPdsch code number. If not,
try to decrease HsPdsch code number.
Recommended value: SF32.
Value range: 1~15.
Content: Number of HS-SCCH codes.
Recommended value: 4.
Value range: 0~500.

Physical value range: 0~50: step: 0.1.


Content: Max sum of HS_PDSCH power and HS_SCCH power.
Physical unit: dBm.
Recommended value: 380.
Value range: -0.5dB, 0.5dB, 1.5 dB, 2.5dB, 3.5dB, 4.5dB, 5.5dB
Content: Measure Power Offset Constant is used to compute Measure Power
Offset. Measure Power Offset = Min(13,CellMaxPower - PcpichPower
- Measure Power Offset Constant)
Physical unit: dB.
Recommended value: 2.5.

d HS_SCCH power is 38 dBm.

odeModeManual,HSPDSCHCODENUM=5, HSSCCHCODENUM=4, HSDPAPOWER=380,HSPDSCHMPOCONSTENU

DSCHMPOCONSTENUM=2.5dB;