Sei sulla pagina 1di 2

Problem Found: System Memory double-bit fill on istream or dstream load detected

. at Mon 24 Oct 2016 13:14:54 GMT-04:00


Problem Report Times:
Event Time: Fri 21 Oct 2016 18:03:23 GMT-04:00
Report Time: Mon 24 Oct 2016 13:14:54 GMT-04:00
Expiration Time: Sat 22 Oct 2016 18:03:23 GMT-04:00
Managed Entity:
System Entity: 2TCM - hp AlphaServer DS10 Series
Service Obligation Data:
Service Obligation: Valid
Service Obligation Number:
System Serial Number:
Service Provider Company Name: Hewlett-Packard Company
Device Type:
AlphaServer DS10 617 MHz
Brief Description:
System Memory double-bit fill on istream or dstream load detected.
Rule ID:
x000A040000072F05
Rule Severity:
Major
Reporting Node:
2TCM
Full Description:
See Recommended Action
Failed Component Type:
Recommended Action:
An uncorrectable double-bit memory fill load event at address x051668F80
has been diagnosed. This System event requires replacement service to be
administered to one or more field replaceable units listed.
********************************************************************
NOTE: Cannot determine if DIMM type is stacked or mono. This needs to be
done by visually inspecting DIMM and replacing with appropriate DIMM
type.
FRU List:
Probability:
Manufacturer:
Device Type:
Physical Location:
FRU Part Number:
FRU Serial Number:
FRU Firmware Rev:

High
512Mb DIMM
Slot Array 1 DIMM J16 and J18
20-00ESA-08 or 20-01ESA-08 or equivalent
Unavailable
Unavailable

FRU Location(s):
Evidence:
Time Error Logged: Fri 21 Oct 2016 18:03:23 GMT-04:00
Unique_ID_Count
: 2514
Unique_ID_Prefix
: 0
Ruleset Revision
: Rev_080214
Notifications:
All

Analysis Mode:
Manual
SEA Version:
System Event Analyzer for Windows V6.1 (Build 136)
WCC Version:
Web-Based Enterprise Services Common Components for
Windows V6.1 (Build 136), member of Web-Based
Enterprise Services Suite for Windows V6.1 (Build
136)