Sei sulla pagina 1di 8

GE Power

Waukesha* gas engines

Power Ratings

Gas Compression & Mechanical Drives


Natural Gas Fueled Engines
Continuous Duty

275GL*+
Model

750 rpm
Disp.

Bore & Stroke


3

16V 275GL+

17,398 in
(285 L)

12V 275GL+

13,048 in
(213.9 L)

C.R.

10.83 x 11.81"
(275 x 300 mm)

9:1

10.83 x 11.81"
(275 x 300 mm)

9:1

VHP*
Model
P9394GSI
P9390GSI
P9390GL
L7044GSI
L7042GSI S4
L7042GL
L7044G
L5794GSI
L5794LT
L5774LT
F3524GSI
F3514GSI
F3524G

Disp.

Bore & Stroke

9388 in3
(153.9 L)

9.375 x 8.5
(238 x 216 mm)

7040 in3
(115.4 L)

9.375 x 8.5"
(238 x 216 mm)

5788 in3
(94.9 L)

8.5 x 8.5"
(216 x 216 mm)

3520 in3
(57.7 L)

9.375 x 8.5"
(238 x 216 mm)

C.R.
9.7:1
8:1
10.5:1
8:1
8:1
10.5:1
8:1
8.2:1
10.2:1
10.2:1
8:1
8:1
8:1

VGF*
Model
P48GSI/GSID
P48GL/GLD
P48GL/GLD
L36GSI/GSID
L36GL/GLD
L36GL
L36GL/GLD
H24GSI/GSID
H24GL/GLD
H24GL
H24GL/GLD
H24G
F18GSI/GSID
F18GL/GLD
F18GL
F18GL/GLD
F18G

Disp.

Bore & Stroke

2924 in3
(48 L)

5.98 x 6.5"
(152 x 165 mm)

2193 in3
(36 L)

5.98 x 6.5
(152 x 165 mm)

1462 in3
(24 L)

5.98 x 6.5"
(152 x 165 mm)

1096 in3
(18 L)

5.98 x 6.5"
(152 x 165 mm)

800 rpm

bhp kWb
6

900 rpm

bhp kWb

3750 2796

1000 rpm

bhp kWb

4000 2983

bhp kWb

50006 37296

4500 3356

3625 2703
28126 20976
27205 20285

3870 2886
30006 22376
29005 21635

4350 3244
33756 25176
32655 24355

48355 36055
37506 27966
36255 27035

800 rpm

900 rpm

1000 rpm

1200 rpm

bhp kWb

bhp kWb

bhp kWb

bhp kWb

13202
13202
11201
9871
9872

9201
6145
6145
5601
4931

9842
9842
8351
7361
7362

6861
4585
4585
4181
3681

1688
14852
14852
12601
11101
11102
690
10351
10055
9345
6301
5551
345

1259
11072
11072
9401
8281
8302
515
7721
7495
6965
4701
4141
257

1875
16502
16502
14001
12331
12332
767
11501
12081
1067
7001
6171
383

1398
12302
12302
10441
9201
9202
572
8581
9011
795
5221
4601
286

2250
19802
19802
16801
14801
14802
920
13801
14501
1280
8401
7401
460

1678
14762
14762
12531
11041
11042
686
10291
10811
954
6261
5521
343

1200 rpm

1400 rpm

1500 rpm

1600 rpm

1800 rpm

C.R.

bhp kWb

bhp kWb

bhp kWb

bhp kWb

bhp kWb

8.6:1
11:1
11:1
8.6:1
11:1
8.7:1
11:1
8.6:1
11:1
8.7:1
11:1
11:1
8.6:1
11:1
8.7:1
11:1
11:1

7104

3554

215

160

830
8304
9103
620
620
620
6853
415
4154
415
4553
250
310
310
310
3403
185

885
8854
9753
670
670
670
7353
445
4454
445
4903
265
335
335
335
3653
200

5304

2654

160

119

620
6204
6803
460
460
460
5103
310
3104
310
3403
186
230
230
230
2553
138

1) Engine available with Low Fuel Pressure System (LFPS) with the same ratings. Refer to Technical Data for LFPS ambient and altitude adjustments.
2) Engine ratings are 700-1000 rpm for low speed turbocharger operation and 1000-1200 rpm for high speed turbocharger operation.
3) These power ratings require pricebook option Code 1100 (176 BMEP). They are available continuously when applied per WKI* Power and
Timing Curve S7079-19. It is permissible to operate at up to 5% overload for two hours in each 24 hour period.
4) Inline engine ratings are 1200 - 1400 rpm for low speed turbocharger operation and 1400 - 1800 rpm for high speed turbocharger operation.
Vee engine ratings are 1100 - 1600 rpm for low speed turbocharger operation and 1400 - 1800 rpm for high speed turbocharger operation.
5) No overload allowed
6) Requires corresponding 1080 option code, no overload allowed
Notes:
All ratings are at an intercooler water temperature of 130F (54.4C).
ISO Standard Power (Continuous Power Rating): The highest load and speed which can be applied 24 hours per day, seven days per week, 365 days
per year except for normal maintenance. It is permissible to operate the engine at up to 10% overload for two hours in every 24 hour period.

660
6604
7303
500
500
500
5503
330
3304
330
3653
198
250
250
250
2753
149

945
9454
10403
710
710
710
7803
475
4754
475
5203
285
355
355
355
3903
215

705
7054
7753
530
530
530
5803
355
3554
355
3903
213
265
265
265
2903
160

1065
10654
11753
800
800
800
8803
530
5304
530
5853
320
400
400
400
4403
240

800
8004
8803
600
600
600
6603
400
4004
400
4403
239
300
300
300
3303
179

Mechanical Drives
Natural Gas Fueled Engines
Intermittent Duty

VHP*

800 rpm

900 rpm

1000 rpm

1200 rpm

Model

Disp.

Bore & Stroke

C.R.

bhp kWb

bhp kWb

bhp kWb

bhp kWb

P9390GSI
P9390GL

9388 in3
(153.9)
7040 in3
(115.4 L)
5788 in3
(94.9 L)

9.375 x 8.5
(238 x 216 mm)
9.375 x 8.5"
(238 x 216 mm)
8.5 x 8.5"
(216 x 216 mm)

8:1
10.5:1

1631 1216
14452 10782

1835 1368
16262 12132

2039 1520
18062 13472

2447 1825
21672 16162

10.5:1

10842 8082

12192 9092

13552 10102

16262 12132

10.2:1

13151 9811

15801 11781

L7042GL
L5794LT

VGF*

1200 rpm

1400 rpm

1500 rpm

1600 rpm

Model

Disp.

Bore & Stroke

C.R.

bhp kWb

bhp kWb

bhp kWb

P48GSI/GSID
P48GL/GLD
L36GSI/GSID
L36GL/GLD
L36GL
H24GSI/GSID
H24GL/GLD
H24GL
H24G
F18GSI/GSID
F18GL/GLD
F18GL
F18G

2924 in3
(48 L)

5.98 x 6.5"
(152 x 165 mm)

2193 in3
(36 L)

5.98 x 6.5
(152 x 165 mm)

1462 in3
(24 L)

5.98 x 6.5"
(152 x 165 mm)

1096 in3
(18 L)

5.98 x 6.5"
(152 x 165 mm)

8.6:1
11:1
8.6:1
11:1
8.7:1
8.6:1
11:1
8.7:1
11:1
8.6:1
11:1
8.7:1
11:1

7854

3954

240

180

910
9104
685
685
685
455
4554
455
275
340
340
340
205

975
9754
735
735
735
490
4904
490
295
365
365
365
220

5854

2904

180

130

680
6804
510
510
510
340
3404
340
205
255
255
255
155

730
7304
550
550
550
365
3654
365
220
275
275
275
165

bhp kWb
1040
10404
780
780
780
520
5204
520
315
390
390
390
240

775
7754
580
580
580
390
3904
390
235
290
290
290
180

1800 rpm
bhp kWb
1175
11754
880
880
880
585
5854
585
355
440
440
440
265

880
8804
660
660
660
440
4404
440
265
330
330
330
195

1) Engine available with Low Fuel Pressure System (LFPS) with the same ratings. Refer to Technical Data for LFPS ambient and altitude adjustments.
2) Engine ratings are 700-1000 rpm for low speed turbocharger operation and 1000-1200 rpm for high speed turbocharger operation.
4) Inline engine ratings are 1200 - 1400 rpm for low speed turbocharger operation and 1400 - 1800 rpm for high speed turbocharger operation. Vee engine ratings are 1100 - 1600 rpm for low speed
turbocharger operation and 1400 - 1800 rpm for high speed turbocharger operation.

Power Units
Mounted Radiator

VGF*
Model
Continuous Duty
H24
F18
Intermittent Duty
H24
F18

1400 rpm

1500 rpm

1600 rpm

1800 rpm

bhp kWb

bhp kWb

bhp kWb

bhp kWb

Disp.

Bore & Stroke

2924 in3 (48 L)


1096 in3 (18 L)

5.98 x 6.5" (152 x 165 mm)


5.98 x 6.5" (152 x 165 mm)

401 299
300 224

428 319
320 239

454 339
340 254

505 377
379 283

2924 in3 (48 L)


1096 in3 (18 L)

5.98 x 6.5" (152 x 165 mm)


5.98 x 6.5" (152 x 165 mm)

443 330
330 246

472 352
353 263

502 374
376 280

560 418
418 312

Notes:
Power Units include engine and radiator mounted to a common skid with a suction fan.
Ratings include deduct for radiator fan power.
Power Units are available in GLU, GLDU, and GSIDU models, refer to the pricebook for more information.
Intermittent Power Rating: The highest load and speed that can be applied in variable speed mechanical system applications only. Operation at this rating is limited to a maximum of 3500 hours per year.
All ratings are at an intercooler water temperature of 130F (54.4C).

Power Generation
Natural Gas Fueled Engine & Enginator*

Remote Radiator Cooling (kWe)


60Hz

275GL*+
16V 275GL+
12V 275GL+

Engines Only (kWb)


50Hz

Continuous

Standby

Continuous

Standby

900 rpm

900 rpm

1000 rpm

1000 rpm

32156
24156

32156
24156

36056
27056

36056
27056

Model
16V 275GL+
12V 275GL+

60Hz

50Hz

Continuous

Continuous

900 rpm

1000 rpm

33566
25176

37296
27966

I.C. Water Temp. (Tcra) 130F 54C

Remote Radiator Cooling (kWe)


60Hz

VHP*
VHP9504GSI
VHP9500GSI
VHP9500GL
VHP7104GSI/GSID
VHP7100GSI/GSID S4
VHP7100GL
VHP5904LT/LTD
VHP5904GSI/GSID
VHP3604GSI/GSID

Engines Only (kWb)


50Hz

Continuous

Standby

Continuous

Standby

1200 rpm

1200 rpm

1000 rpm

1000 rpm

1600
1400
1400
1200
1050
1050
1025
980
600

1600
1750
1540
1200
1050
1155
1025
980
600

1460
1175
1175
11007
875
875
9007
9007
5407

1460
1450
1295
1100
875
965
900
900
540

Model
P9394GSI
P9390GSI
P9390GL
L7044GSI
L7042GSI S4
L7042GL
L5794LT
L5794GSI
F3524GSI

Remote Radiator Cooling (kWe)


60Hz

VGF*
VGF48GL/GLD
VGF48GSI/GSID
VGF36GL
VGF36GLD
VGF36GSI/GSID
VGF24GL
VGF24GLD
VGF24GSI/GSID
VGF18GL
VGF18GLD
VGF18GSI/GSID

60Hz

50Hz

Continuous

Continuous

1200 rpm

1000 rpm

1678
1469
1469
1253
1104
1104
1078
1029
627

1531
1224
1224
11537
920
919
9477
9477
5737

Engines Only (kWb)


50Hz

Continuous

Standby

Continuous

Standby

1800 rpm

1800 rpm

1500 rpm

1500 rpm

8303
750
6203,9
6203
560
4153,9
4153
375
3103,9
3103
280

860
825
6459
645
620
4259
425
410
3159
315
310

6853
625
5153,9
5153
475
3403,9
3403
310
2503,9
2503
230

715
685
5359
535
515
3559
355
340
2609
260
255

Model
P48GL
P48GSI/GSID
L36GL
L36GLD
L36GSI/GSID
H24GL
H24GLD
H24GSI/GSID
F18GL
F18GLD
F18GSI/GSID

60Hz

50Hz

Continuous

Continuous

1800 rpm 1000 rpm


8803
800
6603,9
6603
600
4403,9
4403
400
3303,9
3303
300

7303
660
5503,9
5503
500
3653,9
3653
330
2753,9
2753
250

Power Generation
Radiator Cooling, Unit Mounted

60Hz

50Hz

60Hz

50Hz

Continuous

Standby

Continuous

Standby

Continuous

Standby

Continuous

(kWe)

(kWe)

(kWe)

(kWe)

(kWe)

(kWe)

(kWe)

(kWe)

VHP*

1200
rpm

1200
rpm

1000
rpm

1000
rpm

VGF*

1800
rpm

1800
rpm

1500
rpm

1500
rpm

VHP7104GSI/GSID
VHP7100GSI/GSID S4
VHP7100GL
VHP5904LT
VHP5904LTD
VHP5904GSI/GSID

11501
10001
1025
990
990
9401

11501
10001
1130
990
990
9401

10501,7
8351,7
845
8607
8601,7
8601,7

10501
8351
930
860
8601
8601

VGF48GL/GLD

8103

825

6703

700

VGF48GSID
VGF36GL/GLD
VGF36GSID
VGF24GL/GLD

730
5903,9
530
3903,9

800
6259
600
4059

610
5003,9
450
3253,9

650
5259
490
3509

VHP3604GSI/GSID

5601

5601

5001,7

5001

VGF24GSID
VGF18GL/GLD
VGF18GSID

350
2953,9
265

395
3009
300

295
2403,9
220

325
2509
240

Standby

mobileFLEX
Natural Gas Fueled Engine & Enginator, Continuous Duty
Mobile Power Generation, 60 Hz, EPA Certified
(Tier 2 Certified Per 40 CFR 1048)

Mobile Power Generation, 50 Hz


50 Hz Engines are not EPA Certified (Non-North America Only)

Remote Radiator
Cooling (kWe)

VHP Enginator

1200 rpm

VHP5904GSI-EPA
VHP7104GSI-EPA

980
1200

Engines Only
(kWb)

Engine
L5794GSI-EPA
L7044GSI-EPA

Remote Radiator
Cooling (kWe)

1200 rpm

VHP Enginator

1000 rpm

1029
1253

VHP5904GSI-MOB
VHP7104GSI-MOB

9007
11007

Engines Only
(kWb)

Engine
L5794GSI-MOB
L7044GSI-MOB

1) Engine available with Low Fuel Pressure System (LFPS) with the same ratings. Refer to technical data for LFPS ambient and altitude adjustments.
3) These power ratings require pricebook option Code 1100 (176 BMEP). They are available continuously when applied per WKI Power and Timing Curve S7079-19. It is permissible to operate
at up to 5% overload for two hours in each 24 hour period.
6) Requires corresponding 1080 option code, no overload allowed
7) No overload allowed.
9) Rating is for high compression ratio pistons only.
Generator Standby Power Rating (kWe): This rating applies to those systems used as a secondary source of electrical power. This rating is the output the system will produce
continuously (no overload), 24 hours per day for the duration of the prime power source outage.
Notes: kWe output is based on 0.8 Power Factor Enginator efficiency.

1000 rpm
9477
11537

Alternative Fuels
Continuous Duty
Biogas - Landfill - Digester

VHP*

1000 rpm

1200 rpm

Model

Disp.

Bore & Stroke

C.R.

bhp

kWb

kWe*

bhp

kWb

kWe*

L5794LT

5788 in3
(94.9 L)

8.5 x 8.5" (216 x 216 mm)

10.2:1

12701,7

9471,7

9001,7

14451

10781

10251

VGF*
Model
P48GLD
L36GLD
H24GLD
F18GLD

1500 rpm
Disp.
2924 in3
(48 L)
2193 in3
(36 L)
1462 in3
(24 L)
1096 in3
(18 L)

1800 rpm

Bore & Stroke

C.R.

bhp

kWb

kWe*

bhp

kWb

kWe*

5.98 x 6.5" (152 x 165 mm)

11:1

88511

66011

62511

106011

80011

75011

5.98 x 6.5" (152 x 165 mm)

11:1

67011

50011

47511

80011

60011

56011

5.98 x 6.5" (152 x 165 mm)

11:1

44511

33011

31011

53011

40011

37511

5.98 x 6.5" (152 x 165 mm)

11:1

33511

25011

23011

40011

30011

28011

1) Engine available with Low Fuel Pressure System (LFPS) with the same ratings. Refer to technical data for LFPS ambient and altitude adjustments.
7) No overload allowed.
11) Engine operation using 400 - 500 Btu/ft3 (15.7 - 19.7 MJ/m3). Landfill fuel requires 175F (80C) ICW. Option code 1100 is not available.
Notes:
Low Btu (calorific value) fueled engines operate on fuel with 400 Btu/ft3 (15.7 MJ//m3) or greater saturated low heat (net calorific value) and are
equipped with special low Btu fuel system.
VGF GLD - Gas lean combustion with draw-thru carburetion. Minimum regulated gas supply pressure is 8 H2O (12.44 mbar)
Generator efficiencies are typical values. Please consult with your packager.
All ratings are at an intercooler water temperature of 130F (54.4C).

Waukesha Engine Model


Prefix Designations
Number of cylinders except 275GL
which states actual number of cylinders.
P = 16
H=8
L = 12
F=6

Sux Designations
G
= Naturally aspirated
GSI = Turbocharged intercooled
GSID = Turbocharged intercooled draw-thru
GL = Turbocharged intercooled lean burn
LT = Lean combustion turbulence
GLD = Turbocharged intercooled lean burn draw-thru
LTD = Lean combustion turbulence draw-thru
EPA = United States Environmental Protection Agency (EPA) certified
MOB = Mobile, non-certified, Non-North America

HD-5 Propane Fueled Engines


Continuous Duty

275GL*+
Model
16V 275GL+
12V 275GL+

Disp.

Bore & Stroke

17,398 in3
(285 L)
13,048 in3
(213.9 L)

10.83 x 11.81"
(275 x 300 mm)
10.83 x 11.81"
(275 x 300 mm)

900 rpm

1000 rpm

C.R.

bhp kWb

bhp kWb

9:1

2966 2212

3295 2457

9:1

2224 1658

2471 1843

VHP*
Model
P9394GSI
P9390GSI
P9390GL
L7044GSI
L7042GSI S4
L7042GL
L5794GSI
F3524GSI

900 rpm
Disp.

Bore & Stroke

9388 in3
(153.9 L)

9.375 x 8.5
(238 x 216 mm)

7040 in3
(115.4 L)

9.375 x 8.5"
(238 x 216 mm)

5788 in3
(94.9 L)
3520 in3
(57.7 L)

8.5 x 8.5"
(216 x 216 mm)
9.375 x 8.5"
(238 x 216 mm)

bhp kWb

bhp kWb

bhp kWb

9.7:1
8:1
10.5:1
8:1
8:1
10.5:1

1388
1162
1184
864
864
888

1542
1244
1315
960
960
987

1850
1379
1578
1152
1152
1184

P48GSID
P48GL/GLD
L36GSID
L36GL/GLD
L36GL
H24GSID
H24GL/GLD
H24GL
H24G
F18GSID
F18GL/GLD
F18GL
F18G

1035
867
883
644
644
662

1150
928
981
716
716
736

1380
1029
1177
859
859
883

8.2:1

789 588

877 654

1052 785

8:1

472 352

524 391

629 469

1500 rpm
Disp.

1200 rpm

C.R.

VGF*
Model

1000 rpm

1800 rpm

Bore & Stroke

C.R.

bhp kWb

bhp kWb

2924 in
(48 L)

5.98 x 6.5"
(152 x 165 mm)

2193 in3
(36 L)

5.98 x 6.5
(152 x 165 mm)

1462 in3
(24 L)

5.98 x 6.5"
(152 x 165 mm)

1096 in3
(18 L)

5.98 x 6.5"
(152 x 165 mm)

8.6:1
11:1
8.6:1
11:1
8.7:1
8.6:1
11:1
8.7:1
11:1
8.6:1
11:1
8.7:1
11:1

609
496
457
376
67019
305
249
44519
249
228
187
33519
187

731
604
548
442
80019
366
299
53019
299
274
224
40019
224

454
370
341
280
50019
227
186
33019
186
170
139
25019
139

545
450
409
330
60019
273
223
40019
223
204
167
30019
167

19) Contact Application Engineering regarding stability in Power Generation applications


Notes:
No overload allowed on all HD-5 propane ratings.
Requires a minimum of 34 WKI fuel.
Engine may require optional fuel system.
All ratings are at an intercooler water temperature of 130F (54.4C).
Rating Standard: All models: Ratings conform to ISO 3046/1 (latest version) with a mechanical efficiency of 90% and auxiliary water temperature, Tcra, as specified in the Power Rating Chart, Bulletin 1079 (latest version) limited to 10 F (5.5 C).
Ratings are also valid for SAE J1349, BS 5514, DIN 6271 and API 7B-11C standard atmospheric reference conditions.
Fuel Standard: All natural gas engine ratings are based on 900 BTU/ft3 (35.38 MJ/m3 [25, V(0; 101.325)]) SLHV, 91 WKI minimum, commercial quality natural gas. Refer to S-7884-7 (latest version) for full gaseous fuel specifications.
ISO Standard Power (Continuous Power Rating): The highest load and speed that can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance at ISO standard ambient reference conditions. Unless otherwise
stated, at ISO standard ambient reference conditions, it is permissible to operate the engine at up to 110% of the ISO Standard Power or the maximum power indicated by the intermittent rating, whichever is lower, for two hours in every 24 hour period.
ISO Service Power (Site Continuous Power Rating): The highest load and speed that can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance at the operating and ambient conditions of the site
application. Unless otherwise stated, it is permissible to operate the engine at up to 110% of the ISO Service Power (see the Overload Power definition) or the intermittent power rating available at the site operating and ambient conditions,
whichever is lower, for two hours in every 24 hour period.
Overload Power: The power that an engine is permitted to supply, with a duration and frequency of use depending upon the service application, at stated ambient conditions, immediately after operating at its ISO Service Power rating.
Unless otherwise stated, it is permissible to operate the engine at up to 110% of the ISO Service Power or the intermittent power rating available at the site operating and ambient conditions, whichever is lower, for two hours in every 24 hour
period. For situations without a defined intermittent power, the allowable 10% overload power is reduced from ISO standard ambient reference conditions by the applicable rating adjustments listed in the Intermittent/Standby Power column.
Intermittent Power Rating: The highest load and speed that can be applied in variable speed mechanical system applications only. Operation at this rating is limited to a maximum of 3500 hours per year.
Generator Continuous Power Rating (kWe): The highest load and speed which can be applied 24 hours per day, seven days per week, 365 days per year except for normal maintenance. Unless otherwise stated, it is permissible to operate the
engine at up to 110% of the generator continuous power rating for two hours in every 24 hour period.
Generator Standby Power Rating (kWe): This rating applies to those systems used as a secondary source of electrical power. This rating is the output the system will produce continuously 24 hours per day for the duration of the prime power source
outage. No overload is allowed. This rating may reduce the lifecycle intervals.

www.ge-distributedpower.com
GE Powers Distributed Power business is a leading provider of engines, power equipment and services
focused on generating power at or near the point of use. Distributed Power offers a diverse product
portfolio that includes highly efficient, fuel-flexible, industrial gas engines generating 100 kW to 10 MW
of power for numerous industries globally. In addition, the business provides life cycle support for more
than 35,000 gas engines worldwide to help you meet your business challenges and success metrics
anywhere and anytime. Backed by our authorized service providers in more than 170 countries, GEs
global service network connects with you locally for rapid response to your service needs.
GEs Distributed Power business is headquartered in Jenbach, Austria.
More information on GEs Distributed Power technology:
Austria
Achenseestrae 1-3
6200 Jenbach, Austria
China
No.1 Hua Tuo Rd.
Zhang Jiang Hi-Tech Park
Shanghai 201203, China
Denmark
Samsvej 10
8382 Hinnerup, Denmark
Germany
Carl-Benz-Str. 25
67227 Frankenthal, Germany
Italy
Via Staffoli 1
37062 Dossobuono, Italy

Kenya
The Courtyard
General Mathenge
Drive Westlands
Nairobi, Kenya
Peru
Av. Las Begonias 415
Piso 14, San Isidro Lima 27, Peru
Russia
Presnenskaya Naberezhnaya 10
123317 Moscow
Saudi Arabia
5th Floor Tatweer Towers
Building No. 3&4
King Fahad Road
Riyadh SA 11433, Saudi Arabia

Spain
Calle Josefa Valcarcel 26
Building Merrimack III
28027 Madrid, Spain
The Netherlands
Kelvinring 58
2952 BG Alblasserdam, The Netherlands
USA
Westway Plaza
11330 Clay Road
Houston, TX 77041, USA
1101 West St. Paul Avenue
Waukesha, WI 53188-4999, USA

Imagination at work
GEs Distributed Power business is a unit of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company. 2015 General
Electric Company. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

GEA-18900 1/16

Potrebbero piacerti anche