Questions relating to proper reducer application in centrifugal pump suction lines date back
many decades. Until his death (at age 84, in 1995), world-renowned pump expert Igor Karassik
frequently corresponded with the writer and other pump users on pump-related subjects. We
rarely pass up an opportunity to highlight some of his experience-based comments.
Once, a pump user referred to Fig. 1 and noted that this was quite typical of illustrations found in
many textbooks. In essence, Fig. 1 indicates that, with a suction line entering the pump in the
horizontal plane, the eccentric reducer is placed with the flat at the top. Available texts often give
no indication as to whether the pumpage came from above or below the pump.

Fig. 1. Illustration of eccentric reducer mounting from


Hydraulic Institute Standards.

Igor Karassik agreed that, if the supply source was from above the pump, the eccentric reducer
should be installed with the flat (horizontal) surface at the bottom. Entrained vapor bubbles
could then migrate back into the source instead of staying near the pump suction. If the pump
suction piping entered after a long horizontal run or from below the pump, the flat of the
eccentric reducer should be at the top.1
Still, in many older texts it has been assumed that the pumpage source originated at a level
below the pump suction nozzle. Karassik reminded us that older Hydraulic Institute Standards
commented on the suction pipe slope:
...Any high point in the suction pipe will become filled with air and thus prevent proper operation
of the pump. A straight taper reducer should not be used in a horizontal suction line as an air
pocket is formed in the top of the reducer and the pipe. An eccentric reducer should be used
instead.
This instruction applies regardless of where the pumpage originates. Depending on the
particulars of an installation, trapped vapors can reduce the effective suction line cross-sectional
area. Should that be the case, flow velocities would tend to be higher than anticipated. Higher
friction losses would occur and pump performance would be adversely affected.
In the case of a liquid source above the pump suction, and particularly where the suction line
consists of an eccentric reducer followed by an elbow turned vertically upward and a vertical
pipe lengthall assembled in that sequence from the pump suction flange upstreamit will be
mandatory for the eccentric reducer flat side to be at the bottom. That said, Fig. 2 should clarify
what reliability-focused users need to implement.

HYDRAULIC INSTITUTE STANDARDS

Fig. 2. Suggested modifications for eccentric reducer


mountings.

Also, whenever vapors must be vented against the flow direction, the line size upstream of any
low point must be governed by an important criterion. The line must be a diameter that will limit
the pumpage velocity to values below those where bubbles will rise through the liquid.
In general, it can be stated that wherever a low point exists in a suction line, the horizontal
piping run at that point should be kept as short as possible. In a proper installation, the reducer
flange will thus be located at the pump suction nozzle and there is usually no straight piping
between reducer outlet and pump nozzle. Straight pipe lengths are, however, connected to the
eccentric reducer inlet flange. On most pumps, one usually gets away with five diameters of
straight length next to the reducer. In the case of certain unspecified velocities and other
interacting variables (e.g., viscosity, NPSH margin, pump style, etc.), it might be wise to install
as many as 10 diameters of straight length next to the reducer inlet flange. The two different
rules-of-thumb explain seeming inconsistencies in the literature, where both the 5 and 10-D
rules can be found.