Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
64
18/07/2016
1 / 14
A3C vv 2.64
2.64
I - PARAMETERS
I.1 - General parameters
Element type :
Steel element
L=2m
Lcr,y = 2 m
Horizontal
Simply supported
y-y
I.3 - Cross-section
Profile :
Grade :
Standard :
IPE 200
S355 - JR/J0/J2/K2
EN 10025-2
100
12
200
IPE 200
S355 - JR/J0/J2/K2
fy = 355 MPa
8,5
5,6
Figure 1 : Cross-section
- Geometrical properties :
18/07/2016
2 / 14
A3C vv 2.64
2.64
A
Av,y
Iy
Wel,y
Wpl,y
It
Iw
= 28,48 cm2
= 17 cm2
= 1943,17 cm4
= 194,32 cm3
= 220,64 cm3
= 7,02 cm4
= 12988,09 cm6
m
Av,z
Iz
Wel,z
Wpl,z
= 22,360 kg/m
= 14 cm2
= 142,37 cm4
= 28,47 cm3
= 44,61 cm3
- Steel properties :
Grade :
Standard :
Flange :
Web :
Cross-section :
S355 - JR/J0/J2/K2
EN 10025-2 : 2004
fy = 355 MPa
fy = 355 MPa
fy = 355 MPa
= 0,81
x(*) (m)
0,219 kN/m
Concentrated loads :
No.
x(m)*
Fz (kN)
Position
80
Top
National Annexes:
G,sup
G,inf
Q
= 1,35
= 1,00
= 1,50
M0
M1
= 1,00
= 1,00
No
Design plastic resistance under combined actions (M-N or M-N-V): Exact calculation
18/07/2016
3 / 14
A3C vv 2.64
2.64
The buckling resistance of members in bending is calculated using Clause 6.3.2.2 (EN 1993-1-1)
Interaction factors kij are calculated using:
Annex A
= 1,20
Name
Description
Combination
Calculation
ULS01 (Auto)
1,35G
Yes
ULS02 (Auto)
Yes
Name
SLS01 (Auto)
18/07/2016
Description
Combination
G
Calculation
Yes
4 / 14
A3C vv 2.64
2.64
18/07/2016
Normal force :
Maximum shear force :
Maximum bending moment :
= 0 kN
NEd
|Vz,Ed|max = 54,296 kN (x = 0 m)
|My,Ed |max = 54,148 kNm (x = 1 m)
Left end
Right end
Rz,L = 54,296 kN
Rz,R = 54,296 kN
Section No.
x (m)
Vz,L (kN)
Vz,R (kN)
M (kN.m)
54,296
0,04
54,284
54,284
2,172
0,08
54,272
54,272
4,343
0,12
54,261
54,261
6,513
0,16
54,249
54,249
8,684
0,2
54,237
54,237
10,853
0,24
54,225
54,225
13,023
0,28
54,213
54,213
15,191
0,32
54,201
54,201
17,36
10
0,36
54,19
54,19
19,527
11
0,4
54,178
54,178
21,695
12
0,44
54,166
54,166
23,862
13
0,48
54,154
54,154
26,028
14
0,52
54,142
54,142
28,194
15
0,56
54,13
54,13
30,359
16
0,6
54,118
54,118
32,524
17
0,64
54,107
54,107
34,689
18
0,68
54,095
54,095
36,853
19
0,72
54,083
54,083
39,016
20
0,76
54,071
54,071
41,18
21
0,8
54,059
54,059
43,342
22
0,84
54,047
54,047
45,504
23
0,88
54,036
54,036
47,666
24
0,92
54,024
54,024
49,827
25
0,96
54,012
54,012
51,988
26
54
-54
54,148
27
1,04
-54,012
-54,012
51,988
28
1,08
-54,024
-54,024
49,827
29
1,12
-54,036
-54,036
47,666
30
1,16
-54,047
-54,047
45,504
31
1,2
-54,059
-54,059
43,342
32
1,24
-54,071
-54,071
41,18
5 / 14
A3C vv 2.64
2.64
18/07/2016
Section No.
x (m)
Vz,L (kN)
Vz,R (kN)
M (kN.m)
33
1,28
-54,083
-54,083
39,016
34
1,32
-54,095
-54,095
36,853
35
1,36
-54,107
-54,107
34,689
36
1,4
-54,118
-54,118
32,524
37
1,44
-54,13
-54,13
30,359
38
1,48
-54,142
-54,142
28,194
39
1,52
-54,154
-54,154
26,028
40
1,56
-54,166
-54,166
23,862
41
1,6
-54,178
-54,178
21,695
42
1,64
-54,19
-54,19
19,527
43
1,68
-54,201
-54,201
17,36
44
1,72
-54,213
-54,213
15,191
45
1,76
-54,225
-54,225
13,023
46
1,8
-54,237
-54,237
10,853
47
1,84
-54,249
-54,249
8,684
48
1,88
-54,261
-54,261
6,513
49
1,92
-54,272
-54,272
4,343
50
1,96
-54,284
-54,284
2,172
51
-54,296
6 / 14
A3C vv 2.64
2.64
- ULS02 (Auto) = G
18/07/2016
Normal force :
Maximum shear force :
Maximum bending moment :
NEd
= 0 kN
|Vz,Ed|max = 40,219 kN (x = 0 m)
|My,Ed |max = 40,11 kNm (x = 1 m)
Left end
Right end
Rz,L = 40,219 kN
Rz,R = 40,219 kN
Section No.
x (m)
Vz,L (kN)
Vz,R (kN)
M (kN.m)
40,219
0,04
40,211
40,211
1,609
0,08
40,202
40,202
3,217
0,12
40,193
40,193
4,825
0,16
40,184
40,184
6,432
0,2
40,175
40,175
8,039
0,24
40,167
40,167
9,646
0,28
40,158
40,158
11,253
0,32
40,149
40,149
12,859
10
0,36
40,14
40,14
14,465
11
0,4
40,132
40,132
16,07
12
0,44
40,123
40,123
17,675
13
0,48
40,114
40,114
19,28
14
0,52
40,105
40,105
20,884
15
0,56
40,097
40,097
22,488
16
0,6
40,088
40,088
24,092
17
0,64
40,079
40,079
25,695
18
0,68
40,07
40,07
27,298
19
0,72
40,061
40,061
28,901
20
0,76
40,053
40,053
30,503
21
0,8
40,044
40,044
32,105
22
0,84
40,035
40,035
33,707
23
0,88
40,026
40,026
35,308
24
0,92
40,018
40,018
36,909
25
0,96
40,009
40,009
38,51
26
40
-40
40,11
27
1,04
-40,009
-40,009
38,51
28
1,08
-40,018
-40,018
36,909
29
1,12
-40,026
-40,026
35,308
30
1,16
-40,035
-40,035
33,707
31
1,2
-40,044
-40,044
32,105
32
1,24
-40,053
-40,053
30,503
33
1,28
-40,061
-40,061
28,901
34
1,32
-40,07
-40,07
27,298
7 / 14
A3C vv 2.64
2.64
18/07/2016
Section No.
x (m)
Vz,L (kN)
Vz,R (kN)
M (kN.m)
35
1,36
-40,079
-40,079
25,695
36
1,4
-40,088
-40,088
24,092
37
1,44
-40,097
-40,097
22,488
38
1,48
-40,105
-40,105
20,884
39
1,52
-40,114
-40,114
19,28
40
1,56
-40,123
-40,123
17,675
41
1,6
-40,132
-40,132
16,07
42
1,64
-40,14
-40,14
14,465
43
1,68
-40,149
-40,149
12,859
44
1,72
-40,158
-40,158
11,253
45
1,76
-40,167
-40,167
9,646
46
1,8
-40,175
-40,175
8,039
47
1,84
-40,184
-40,184
6,432
48
1,88
-40,193
-40,193
4,825
49
1,92
-40,202
-40,202
3,217
50
1,96
-40,211
-40,211
1,609
51
-40,219
8 / 14
A3C vv 2.64
2.64
18/07/2016
Load cases
wz,max (mm)
x (m)
3,28
9 / 14
A3C vv 2.64
2.64
N,max
= 0 < 1 =>Satisfied
Vz,max
My,max
MyN,max
MyVz,max
MyNVz,max
- Web resistance
No verification required because: hw / tw < 72 / ( = 1,2)
- Member resistance - Flexural buckling about the major axis
No verification required because:
NEd = 0
NEd = 0
EN 1993-1-1 6.3.2.2
a
= 0,21
LT
= 0,4
LT,0
18/07/2016
NEd = Mz,Ed = 0
10 / 14
A3C vv 2.64
2.64
N,max
= 0 < 1 =>Satisfied
Vz,max
My,max
MyN,max
MyVz,max
MyNVz,max
- Web resistance
No verification required because: hw / tw < 72 / ( = 1,2)
- Member resistance - Flexural buckling about the major axis
No verification required because:
NEd = 0
NEd = 0
EN 1993-1-1 6.3.2.2
a
= 0,21
LT
= 0,4
LT,0
18/07/2016
NEd = Mz,Ed = 0
11 / 14
A3C vv 2.64
2.64
= 0 < 1 =>Satisfied
Vz,max
My,max
MyN,max
MyV,max
MyNV,max
- Web resistance
Shear buckling:
No verification required
- Member resistance
Flexural buckling about the major axis:
No verification required
No verification required
18/07/2016
No verification required
12 / 14
A3C vv 2.64
2.64
V.2 - Vibrations
Minimum natural frequency :
fmin = 8,65 Hz (Loads case G)
Verification :
fmin = 8,65 Hz > 2,6 Hz =>Satisfied
18/07/2016
13 / 14
A3C vv 2.64
2.64
Warning !
This software facilitates the preliminary engineering studies with respect to steel constructions. Based on calculation methods
complying with the principles of the applied standards, this software enables to make a certain number of verifications in view of
evaluating a solution for a pre-design. It does not enable to analyse all situations and to make in an exhaustive way all relevant
calculations needed for a study of execution which requires in every case the advice of an external Engineering Office.
Given the complexity of the calculation methods, this software is only intended for professional users active in the sector of steel
constructions (who are fully aware of the possibilities, limits and its adequacy thereof for specific practical cases). The users shall
use the software under his own responsibility and at his own risks.
This software may be used free of charge. No right is granted to the user of the software, the property and intellectual rights of which
continue to belong exclusively to ArcelorMittal Commercial Sections S.A. (or, depending on the case, to the company of the
ArcelorMittal Group who is owner of these rights.) No warranty is granted to the user. ArcelorMittal Commercial Sections S.A. and/or
any other subsidiaries of the ArcelorMittal Group cannot be held liable for any loss or damage directly and/or indirectly sustained as
a result of the use of the software. The user undertakes to hold ArcelorMittal Commercial Sections S.A. free and harmless from any
claim and any direct, indirect and/or consequential damages, in particular those resulting from an incorrect or inappropriate use or a
use made for an inadequate or inappropriate purpose of the software.
All the preliminary design notes done by ARCELORMITTAL and/or by any other subsidiaries of the ARCELORMITTAL group are
based on the information received from the Customer. These preliminary design notes are given for guidance only. As such, they do
not commit our company and/or any other subsidiary of the ARCELORMITTAL group to the achievement of a result expected by the
Customer and/or any third person. These preliminary design notes cannot replace all the design notes which shall be done by an
external engineering office chosen by the Customer. ARCELORMITTAL and/or any other subsidiary of the ARCELORMITTAL group
cannot be held liable for any loss or damage, directly or indirectly sustained as a result of the use of the preliminary design notes
done by ARCELORMITTAL andr by any other subsidiaries of the ARCELORMITTAL group, whatever the origin of the damage.
18/07/2016
14 / 14