Home Switchgear Protections Quiz Questions and Answers 109 Switchgear Protections - Electrical Engineering Multiple Choice Questions and Answers
Labels
A.C. Fundamentals
A.C. Fundamentals and circuit theory Online
Quiz Questions
AC Fundamentals and Circuit Theory Online
Quiz Questions
Airport Engineering Objective Questions and
Answers
Airport Engineering Online Quiz Questions
Applied Mechanics and Graphic Statics
Objective Questions and Answers
Applied Mechanics and Graphic Statics Online
Quiz Questions
Building Materials and Construction Objective
Questions and Answers
Cables Online Quiz Questions
Cables Online Quiz Questions and Answers
Chemical Engineering Multiple choice
Questions and Answers
CIRCUIT THEORY AND ELECTRIC NETWORKS
Questions and Answers
Circuits and Circuit Theory Quiz Questions
and Answers
Civil Engineering Interview Questions and
Answers pdf download free
competitive and entrance examinations
5. Which of the following medium is employed for extinction of arc in air circuit breaker ?
(a) Water
(b) Oil
(c) Air
(d) SF6
Ans: c
Compressors
6. With which of the following, a circuit breaker must be equipped for remote operation ?
(a) Inverse time trip
(b) Time-delay trip
(c) Shunt trip
(d) None of the above
(e) All of the above
Ans: c
(a) induction
(b) solid state
(c) thermal
(d) electromagnetic
(e) all above
Ans: e
answers
13. Thermal overload relays are used to protect the motor against over current due to
(a) short-circuits
(b) heavy loads
(c) grounds
(d) all of the above
Ans: b
17. In order that current should flow without causing excessive heating or voltage drop, the relay contacts should
(a) have low contact resistance
(b) be clean and smooth
(c) be of sufficient size and proper shape
(d) have all above properties
Ans: d
18. Circuit breakers usually operate under
(a) transient state of short-circuit current
(b) sub-transient state of short-circuit current
(c) steady state of short-circuit current
(d) after D.C. component has ceased
Ans: a
19. Circuit breakers are essentially
(a) current carrying contacts called electrodes
(b) arc extinguishers
(c) circuits to break the system
(d) transformers to isolate the two systems
(e) any of the above
Ans: a
The current zero interruption, in oil and air blast circuit breakers, is achieved by
(a) lengthening of the gap
(b) cooling and blast effect
(c) both (a) and (b)
(d) deionizing the oil with forced air
(e) none of the above
Ans: c
21. Air blast circuit breaker is used for
(a) over currents
(b) short duty
(c) intermittant duty
(d) repeated duty
Ans: d
22. An efficient and a well designed protective relaying should have
(a) good selectivity and reliability
(b) economy and simplicity
(c) high speed and selectivity
(d) all of the above
Ans: d
Engines
Environmental Engineering Objective type
Questions and Answers
Environmental Engineering Online Quiz
Questions
Fluid Mechanics Objective type Questions and
Answers
Fluid Mechanics Online Quiz Questions
Fluid Mechanics Problems Quiz multiple
choice questions download free
Gas Turbines and Jet Engines Model paper1
29. Protective relays are devices that detect abnormal conditions in electrical circuits by measuring
(a) current during abnormal condition
(b) voltage during abnormal condition
(c) constantly the electrical quantities which differ during normal and abnormal conditions
(d) none of the above
Ans: c
30. The voltage appearing across the contacts after opening of the circuit breaker is called______voltage.
(a) recovery
(b) surge
(c) operating
(d) arc
(e) none of the above
Ans: a
(a) Generators
(b) Motors
(c) Transmission line
(d) Transformers
Ans: a
66 relay is preferred for phase fault on short transmission line.
(a) Induction type
(b) Reactance
(c) Impedance
(d) None of the above
Ans: b
67. Distance relays are generally
(a) split-phase relays
(b) reactance relays
(c) impedance relays
(d) none of the above
Ans: d
68. For which of the following ratings of the transformer differential protection is recommended ?
(a) above 30 kVA.
(b) equal to and above 5 MVA
(c) equal to and above 25 MVA
(d) none of the above
Ans: b
69. A _______ is used to measure the stator % winding temperature of the generator.
(a) thermocouple
(b) pyrometer
(c) resistance thermometer
(d) thermometer
Ans: c
70. The under voltage relay can be used for
(a) generators
(b) busbars
(c) transformers
(d) motors
(e) all of the above
Ans: e
71. The relay with inverse time characteristic will operate within
(a) 1.5 sec
(b) 5 to 10 sec
(c) 5 to 20 sec
(d) 20 to 30 sec
(e) none of the above
Ans: b
72. The single phasing relays are used for the protection of
(a) single phase motors only
(b) two phase motors only
(c) two single phase motors running in parallel
(d) three phase motors
Ans: d
73. Which of the following devices will receive voltage surge first travelling on the transmission line ?
(a) Lightning arresters
(b) Relays
(c) Step-down transformer
(d) Switchgear
Ans: a
74. Which of the following parameter can be neglected for a short line ?
(a) Inductance
(b) Capacitance
(c) Resistance
(d) Reactance
Ans: b
75. Series reactors should have
(a) low resistance
(b) high resistance
(c) low impedance
(d) high impedance
Ans: a
76. Which of the following circuit breakers has high reliability and minimum maintenance ?
(a) Air blast circuit breakers
(b) Circuit breaker with SF6 gas
(c) Vacuum circuit breakers
(d) Oil circuit breakers
Ans: b
77. Arc in a circuit breaker is interrupted at
(a) zero current
(b) maximum current
(c) minimum voltage
(d) maximum voltage
Ans: a
78 transmission line has reflection coefficient as one.
(a) Open circuit
(b) Short-circuit
(e) Long
(d) None of the above
Ans: a
79. What will be the reflection co-efficient of the wave of load connected to transmission line if surge impedance of the line is equal to load ?
(a) Zero
(b) Unity
(c) Infinity
(d) None of the above
Ans: a
80. The inverse definite mean time relays are used for over current and earth fault protection of transformer against
(a) heavy loads
(b) internal short-circuits
(c) external short-circuits
(d) all of the above
Ans: b
81. Over voltage protection is recommended for
(a) hydro-electric generators
(b) steam turbine generators
(c) gas turbine generators
(d) all of the above
(e) none of the above
Ans: d
82. Air blast circuit breakers for 400 kV power system are designed to operate in
(a) 100 microsecond
(b) 50 millisecond
(c) 0.5 sec
(d) 0.1 sec
Ans: b
2 comments:
zulfiqar ali 11 November 2015 at 22:31
we are expert in manufacturing the electric appliances. we make many parts which related the electric world. we are serving in solar panels
manufacturing, DP panles and DP, motor control panels, manual power factor , PFI, LT switchgear, feeder pillars, power distribution board and its type,
generator cubical body, cable laders, cables trays and UPS , UPS panels and cabinets. Email us to get our services "zulifiqarali6662@gmail.com" and
call us to +923004546662 or +923134546662. thank you for interest.
Reply
Comment as:
Publish
Select profile...
Preview
Newer Post
Home
Popular Posts
Older Post
109 TOP Measurement and Instrumentation - Electrical Engineering Multiple choice Questions and Answers
Latest Measurement and Instrumentation Questions and Answers List 1. The use of _____ instruments is merely confined within laboratories ...
118 TOP Current Electricity - Electrical Engineering Multiple Choice Questions and Answers
Latest Current Electricity Questions and Answers List 1. The S.I. unit of power is (a) Henry (b) coulomb (c) watt (d) watt-hour A...
250 TOP I.C. Engines - Mechanical Engineering Multiple choice Questions and Answers List
I.C. Engines Questions and Answers pdf free download 1. The working cycle in case of four stroke engine is completed in following number...
102 TOP Transmission and Distribution - Electrical Engineering Multiple Choice Questions and Answers
Latest Transmission and Distribution Questions and Answers List 1. By which of the following systems electric power may be transmitted ? ...
Powered by Blogger.