MASTERYS BC-L

Three-phase UPS

from 10 to 40 kVA
solutions for your business critical applications
The solution for
Protection of Mission Critical
IT applications:
> Data centres
> IT networks
> Healthcare
Protection of industrial
applications:
> Medium/large companies
> Production processes
> Automates
Protection of service sectors:
> Retail stores
MASTE_067_A

> Universities
> Airports/Railways

Multivoltage
Input:
> 208-220-230-240 V
> 460-480 V
Output:
> 208-220-230-240 V
> 460-480 V

Flexible voltage and frequency

Tailored to your environment

2 models: 460-480 V and 208-220-230240 V


All possible input and output voltage
combinations are allowed in the 208-220230-240 V model.
50 Hz, 60 Hz and frequency converter mode
are allowed and simply configurable for all
models.

RS232/RS485 interface
LAN standard connection (Ethernet) and
second RS232 interface
2 slots for ADC interface and NET VISION
Ethernet adaptor.
Compatible with Open Vented Lead Acid,
Valve Regulated Lead Acid (VRLA) and
Nickel Cadmium batteries.
Extended battery life and performance EBS
battery charging management reduces the
battery aging.
IP20 degree of protection as standard.

High performance
On-line double conversion mode VFI-SS-111
(IEC62040-3), that is the only UPS workingmode that assures total load protection
against all the possible quality problems.
With Clean Rectifier (input PF=0.99 and
the lowest input current distortion < 2.5%),
MASTERYS BC-L optimizes the upstream
infrastructure without over rating the supply
system (i.e. generator sets, switches, cables,
protection devices).
Advanced mimic panel for a full supervision.
Multilanguage.

Extreme robustness
The UPS has an input transformer with
galvanic isolation that isolates the UPS and
the load from all the dangerous fast transient
and disturbances present on the mains.
It allows also the creation of a local clean
neutral reference.
Intrinsic filter against lightning surges.
Robust steel cabinet.

Socomec UPS C/Nord, 22 Pol. Ind. Buvisa E - 8329 Tei (Barcelona)


Tel. +34 935 407 575 info.ups.sib@socomec.com www.socomec.com

MASTERYS BC-L
from 10 to 40 kVA
Three-phase UPS

Standard electrical features

Easy, quick and safe maintenance

Internal manual bypass.


Backfeed protection: detection circuit.
EBS (Expert Battery System) for battery
management.

Frontal access for input / output cabling,


spares replacement and preventative
maintenance.
Full front extraction of the power module.
All electronic components are extractable
and accessable from the front of the unit.
Fans replacement while the unit is working.
Internal manual bypass for an easy
maintenance without power interruption.

Electrical options
External battery cabinet.
External temperature sensor.
Additional battery chargers.

Standard communication
features
MODBUS/JBUS RTU.
2 slots for communication options.

Communication options
MASTE_068_A

Dry-contact interface.
Dry-contact interface + temperature sensor.
MODBUS TCP.
PROFIBUS.
NET VISION: professional WEB/SNMP
interface for UPS monitoring and shutdown
management of several operating systems.

Technical data
Sn [VA]
Pn [W]
INPUT

10000
8000

MASTERYS BC-L
20000
16000

15000
12000

Voltage tolerance
Rated frequency
Power factor / THDI
OUTPUT

-15% to +15%
50/60Hz 10%
> 0.99 / <2.5%
208 V / 220 V / 230 V / 240 V
460 V / 480 V
2%
1% on linear load, < 6% on distorting load
50/60 Hz
2% (configurable from 1% to 8% with Generating Set)
125% for 10 minutes, 150% for 1 minute

Rated voltage

DOC_171013

40000
32000

208 V / 220 V / 230 V / 240 V


460 V / 480 V

Rated voltage

Voltage tolerance
Voltage harmonic distortion
Rated frequency
Frequency tolerance
Overload
BYPASS
Automatic
CONNECTIONS
Input/Output
Communication interface
ENVIRONMENT
Operating ambient temperature
Acoustic level at 1 m (ISO 3746)
UPS CABINET
Dimensions W x D x H
Weight
STANDARDS
Safety
EMC
Performance

30000
24000

rated output voltage 15% (configurable with from 10% to 20% for operating with GenSet)
terminals / terminals
RS232/485, RS232, LAN connection
from 0C up to +35C (from 15C to 25C for maximum battery life)
< 55 dBA

260 kg

600 x 800 x 1400 mm


340 kg

315 kg

410 kg

495 kg

IEC 62040-1-1, IEC 60950-1, (EN) IEC 62040-2 (2nd edition), EN 50091-2 class A
EN 62040-2
EN 62040-3 (VFI-SS-111)

VALID FOR FRANCE

VALID FOR ITALY

ISO 9001:2008
FM 28237

ISO14001:2004
EMS 553476

Non contractual document.