4thOctober2013, 9:56
Display
#1
TanmayTega
ApplicationEngineer
TegaIndustriesLtd.[eDir]
SelectingScreenSizeandOpenArea
Needhelponhowtofindoutscreeningefficiencyandhowitcanberelatedtoscreensize
selectionwithrespecttoscreenefficiencyfactor.Whatarethefactorsthatweshouldconsiderfor
findingouttheoverallscreeningareaofascreendeck.
WhataretheotherprominentscreeningmodelapartfromKarramodel.
ReplyWithQuote
5thOctober2013, 1:47
#2
GeorgeBaker
VicePresidentCorporateCommunications
AssinckLtd.[eDir]
Screenefficiencyfactors
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
1/9
9/28/2016
SelectingScreenSizeandOpenArea
FORPropervibratingscreensizingtodetermine:widthxlengthxnumberofdecksxEFFICIENCY
factor.YouneedtogetyourhandsontheVSMAhandbook.Inthathandbookislocatedthe
VIBRATINGSCREENSIZINGFORMULAwhichALLvibratingscreenmanufacturersusetypicallywith
veryslightmodificationstotheirownformulastoeitherbemoreconservativeonTPHorless
conservativeinTPH.Moreconservative=moresafetyfactor=abiggerscreenneededandless
conservative=smallerscreenneeded....andlessdollars.
SELECTIONOFSCREENSIZEANDTYPE:
applyingscreeningareaformula
aseparatecalaculationisrequiredforeachdeckofamultipledeckscreen,butthesameformula
isusedineachdeckcalculation.
SCREENINGAREA=U
______________________________________=SQUAREFEET
AXBXCXDXEXFXGXHXJ
U=UNDERSIZE:AmountinstphOFMATERIALINTHEFEEDTOTHEDECKTHATISSMALLERTHAN
ASPECIFIEDAPERTUREOROPENING
DIVIDEDBY:
FACTORU:(UNDERSIZE)thismeanstheamountofSTPHofmaterialinthefeedtothedeckthat
issmallerthanaspecifiedaperture.
FACTORA:(BASICCAPACITY):thismeansapredeterminedrateofmaterialinSTPHthrougha
squarefootofaspecifiedopeningwhenthefeedtothedeckcontains25%oversize(factorB)and
40%halfsize(factorC)
FACTORB:(OVERSIZE):Actual%ofmaterialinthefeedtothedeckthatislargerthana
specifiedaperture.(thiswilladjustFACTORA)tosuittheconditions
FACTORC:(HALFSIZE):Actual%ofmaterialinthefeedtothedeckthatisonehalfthesizeofa
specifiedaperture.(AlsoadjustFactorA)
FACTORD:(DECKLOCATION):appliesformultipledeckscreeners.Totalscreeningareais
availableforthetopdeckseparation.timedelayformaterialtopassthetopdeckandthe2nd
deckorthe3rddeckleavesLESSeffectiveopenareaavailable.Thisfactorisexpressedina
percentofthetopdeckeffectivearea.
FACTORE:(WETSCREENING)ifawetscreen,thisfactorapplieswhenwaterissprayedonthe
materialasitmovesdownthescreeningdeck.Generally,about5to7GPM(gallonsperminute)
areusedpereachSTPHofsolidsfedtothescreen.thevolumeofwaterrequiredshouldbe
suppliedsothataportioniscombinedwiththesolidsintoafeedboxtoprepareaSLURRYFEED
tothescreen.thebalanceofwaterisaddedthroughaseriesofspraybarslocatedoverthe
screeningdeck.
FACTORF:(MATERIALWEIGHT):iftheweightofthematerialisNOT100LBSperCUFTbulk
density...whichequalstheAfactor.usethisformulaLBSpercufootofactualmaterialdividedby
100.andinsertthisnumberintoformula.
FACTORG:(SCREENSURFACEMEDIATYPEOPENAREA):Appileswhenopenareaofscreening
surfaceislessthantheopenareashowninFACTORA,capacitychart.FACTORG=
%openareaofscreensurfacebeingusedDIVIDEDBY%ofopenareaindicatedinthecapacity
chart
FACTORH:(SHAPEOFTHEOPENING):Applieswhenrectangularopeningsareused.Slottedor
oblaongopeningswillinfact,PASSmorematerialpersquarefootthanasquareopg.
FACTORJ:(EFFICIENCY):ApplieswhentheobjectiveorrequiredscreeningEFFICIENCYislessthan
thestandardAFACTOR,whichis95%EFFICIENCY.Forexample:ifscalping,youdonotneedtobe
95%efficient,morelike85%ifcompletelyacceptable.lessefficiency=smallerscreenneeded.
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
2/9
9/28/2016
SelectingScreenSizeandOpenArea
SCREENEFFICIENCY:youmustdoublechecktheBEDDEPTHFACTORS....MOSTMOSTCRITICAL
afterarrivingatthewidthvslengthneededfromtheforumulaabove.
HOPINGTHISHELPS..IFMOREQUESTIONS,LETerRIP.GeorgeBakerMODERATOR.
(ItriedtocopymyVSMAFORMULAandmyscannerwasnotcooperating...........so,Itypedall
this....painful)
Needhelponhowtofindoutscreeningefficiencyandhowitcanberelatedtoscreensize
selectionwithrespecttoscreenefficiencyfactor.Whatarethefactorsthatweshouldconsiderfor
findingouttheoverallscreeningareaofascreendeck.
WhataretheotherprominentscreeningmodelapartfromKarramodel.[/QUOTE]
BestRegards,
GeorgeBaker
RegionalSalesMgrCanada
TELSMITHInc
Mequon,Wisconsin
15192426664Cell
E:(work)gbaker@telsmith.com
E:(home)gggman353@gmail.com
website:www.telsmith.com
Manufacturerofportable,modularandstationarymineralprocessingequipmentfortheaggregate
andminingindustries.
ReplyWithQuote
5thOctober2013, 1:50
#3
GeorgeBaker
VicePresidentCorporateCommunications
AssinckLtd.[eDir]
Aggflowsoftware
ONELASTPOINT:ifyoubuytheAGGFLOWSIZINGPROGRAMfromBEDROCKRESOURCES.COMitis
allcontainedinthatsoftwaretosizescreensandcrushers.oryoucanjustordertheVSMA
HANDBOOKonline....forstrictlyscreeningformulasandtroubleshooting.GEORGEBAKER.
....................
FORPropervibratingscreensizingtodetermine:widthxlengthxnumberofdecksxEFFICIENCY
factor.YouneedtogetyourhandsontheVSMAhandbook.Inthathandbookislocatedthe
VIBRATINGSCREENSIZINGFORMULAwhichALLvibratingscreenmanufacturersusetypicallywith
veryslightmodificationstotheirownformulastoeitherbemoreconservativeonTPHorless
conservativeinTPH.Moreconservative=moresafetyfactor=abiggerscreenneededandless
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
3/9
9/28/2016
SelectingScreenSizeandOpenArea
conservative=smallerscreenneeded....andlessdollars.
SELECTIONOFSCREENSIZEANDTYPE:
applyingscreeningareaformula
aseparatecalaculationisrequiredforeachdeckofamultipledeckscreen,butthesameformula
isusedineachdeckcalculation.
SCREENINGAREA=U
______________________________________=SQUAREFEET
AXBXCXDXEXFXGXHXJ
U=UNDERSIZE:AmountinstphOFMATERIALINTHEFEEDTOTHEDECKTHATISSMALLERTHAN
ASPECIFIEDAPERTUREOROPENING
DIVIDEDBY:
FACTORU:(UNDERSIZE)thismeanstheamountofSTPHofmaterialinthefeedtothedeckthat
issmallerthanaspecifiedaperture.
FACTORA:(BASICCAPACITY):thismeansapredeterminedrateofmaterialinSTPHthrougha
squarefootofaspecifiedopeningwhenthefeedtothedeckcontains25%oversize(factorB)and
40%halfsize(factorC)
FACTORB:(OVERSIZE):Actual%ofmaterialinthefeedtothedeckthatislargerthana
specifiedaperture.(thiswilladjustFACTORA)tosuittheconditions
FACTORC:(HALFSIZE):Actual%ofmaterialinthefeedtothedeckthatisonehalfthesizeofa
specifiedaperture.(AlsoadjustFactorA)
FACTORD:(DECKLOCATION):appliesformultipledeckscreeners.Totalscreeningareais
availableforthetopdeckseparation.timedelayformaterialtopassthetopdeckandthe2nd
deckorthe3rddeckleavesLESSeffectiveopenareaavailable.Thisfactorisexpressedina
percentofthetopdeckeffectivearea.
FACTORE:(WETSCREENING)ifawetscreen,thisfactorapplieswhenwaterissprayedonthe
materialasitmovesdownthescreeningdeck.Generally,about5to7GPM(gallonsperminute)
areusedpereachSTPHofsolidsfedtothescreen.thevolumeofwaterrequiredshouldbe
suppliedsothataportioniscombinedwiththesolidsintoafeedboxtoprepareaSLURRYFEED
tothescreen.thebalanceofwaterisaddedthroughaseriesofspraybarslocatedoverthe
screeningdeck.
FACTORF:(MATERIALWEIGHT):iftheweightofthematerialisNOT100LBSperCUFTbulk
density...whichequalstheAfactor.usethisformulaLBSpercufootofactualmaterialdividedby
100.andinsertthisnumberintoformula.
FACTORG:(SCREENSURFACEMEDIATYPEOPENAREA):Appileswhenopenareaofscreening
surfaceislessthantheopenareashowninFACTORA,capacitychart.FACTORG=
%openareaofscreensurfacebeingusedDIVIDEDBY%ofopenareaindicatedinthecapacity
chart
FACTORH:(SHAPEOFTHEOPENING):Applieswhenrectangularopeningsareused.Slottedor
oblaongopeningswillinfact,PASSmorematerialpersquarefootthanasquareopg.
FACTORJ:(EFFICIENCY):ApplieswhentheobjectiveorrequiredscreeningEFFICIENCYislessthan
thestandardAFACTOR,whichis95%EFFICIENCY.Forexample:ifscalping,youdonotneedtobe
95%efficient,morelike85%ifcompletelyacceptable.lessefficiency=smallerscreenneeded.
SCREENEFFICIENCY:youmustdoublechecktheBEDDEPTHFACTORS....MOSTMOSTCRITICAL
afterarrivingatthewidthvslengthneededfromtheforumulaabove.
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
4/9
9/28/2016
SelectingScreenSizeandOpenArea
HOPINGTHISHELPS..IFMOREQUESTIONS,LETerRIP.GeorgeBakerMODERATOR.
(ItriedtocopymyVSMAFORMULAandmyscannerwasnotcooperating...........so,Itypedall
this....painful)
Needhelponhowtofindoutscreeningefficiencyandhowitcanberelatedtoscreensize
selectionwithrespecttoscreenefficiencyfactor.Whatarethefactorsthatweshouldconsiderfor
findingouttheoverallscreeningareaofascreendeck.
WhataretheotherprominentscreeningmodelapartfromKarramodel.[/QUOTE][/QUOTE]
BestRegards,
GeorgeBaker
RegionalSalesMgrCanada
TELSMITHInc
Mequon,Wisconsin
15192426664Cell
E:(work)gbaker@telsmith.com
E:(home)gggman353@gmail.com
website:www.telsmith.com
Manufacturerofportable,modularandstationarymineralprocessingequipmentfortheaggregate
andminingindustries.
ReplyWithQuote
5thOctober2013, 2:48
#4
GeorgeBaker
VicePresidentCorporateCommunications
AssinckLtd.[eDir]
VSMAScreenSizingFormulaSCANNED......
FINALLYgotmyscannerworking:herearethepagesfromVSMA.
OriginallyPostedbyGeorgeBaker
ONELASTPOINT:ifyoubuytheAGGFLOWSIZINGPROGRAMfromBEDROCKRESOURCES.COMitis
allcontainedinthatsoftwaretosizescreensandcrushers.oryoucanjustordertheVSMA
HANDBOOKonline....forstrictlyscreeningformulasandtroubleshooting.GEORGEBAKER.
....................
FORPropervibratingscreensizingtodetermine:widthxlengthxnumberofdecksxEFFICIENCY
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
5/9
9/28/2016
SelectingScreenSizeandOpenArea
factor.YouneedtogetyourhandsontheVSMAhandbook.Inthathandbookislocatedthe
VIBRATINGSCREENSIZINGFORMULAwhichALLvibratingscreenmanufacturersusetypicallywith
veryslightmodificationstotheirownformulastoeitherbemoreconservativeonTPHorless
conservativeinTPH.Moreconservative=moresafetyfactor=abiggerscreenneededandless
conservative=smallerscreenneeded....andlessdollars.
SELECTIONOFSCREENSIZEANDTYPE:
applyingscreeningareaformula
aseparatecalaculationisrequiredforeachdeckofamultipledeckscreen,butthesameformulais
usedineachdeckcalculation.
SCREENINGAREA=U
______________________________________=SQUAREFEET
AXBXCXDXEXFXGXHXJ
U=UNDERSIZE:AmountinstphOFMATERIALINTHEFEEDTOTHEDECKTHATISSMALLER
THANASPECIFIEDAPERTUREOROPENING
DIVIDEDBY:
FACTORU:(UNDERSIZE)thismeanstheamountofSTPHofmaterialinthefeedtothedeckthatis
smallerthanaspecifiedaperture.
FACTORA:(BASICCAPACITY):thismeansapredeterminedrateofmaterialinSTPHthrougha
squarefootofaspecifiedopeningwhenthefeedtothedeckcontains25%oversize(factorB)and
40%halfsize(factorC)
FACTORB:(OVERSIZE):Actual%ofmaterialinthefeedtothedeckthatislargerthanaspecified
aperture.(thiswilladjustFACTORA)tosuittheconditions
FACTORC:(HALFSIZE):Actual%ofmaterialinthefeedtothedeckthatisonehalfthesizeofa
specifiedaperture.(AlsoadjustFactorA)
FACTORD:(DECKLOCATION):appliesformultipledeckscreeners.Totalscreeningareaisavailable
forthetopdeckseparation.timedelayformaterialtopassthetopdeckandthe2nddeckorthe3rd
deckleavesLESSeffectiveopenareaavailable.Thisfactorisexpressedinapercentofthetopdeck
effectivearea.
FACTORE:(WETSCREENING)ifawetscreen,thisfactorapplieswhenwaterissprayedonthe
materialasitmovesdownthescreeningdeck.Generally,about5to7GPM(gallonsperminute)are
usedpereachSTPHofsolidsfedtothescreen.thevolumeofwaterrequiredshouldbesuppliedso
thataportioniscombinedwiththesolidsintoafeedboxtoprepareaSLURRYFEEDtothescreen.
thebalanceofwaterisaddedthroughaseriesofspraybarslocatedoverthescreeningdeck.
FACTORF:(MATERIALWEIGHT):iftheweightofthematerialisNOT100LBSperCUFTbulk
density...whichequalstheAfactor.usethisformulaLBSpercufootofactualmaterialdividedby100
.andinsertthisnumberintoformula.
FACTORG:(SCREENSURFACEMEDIATYPEOPENAREA):Appileswhenopenareaofscreening
surfaceislessthantheopenareashowninFACTORA,capacitychart.FACTORG=
%openareaofscreensurfacebeingusedDIVIDEDBY%ofopenareaindicatedinthecapacity
chart
FACTORH:(SHAPEOFTHEOPENING):Applieswhenrectangularopeningsareused.Slottedor
oblaongopeningswillinfact,PASSmorematerialpersquarefootthanasquareopg.
FACTORJ:(EFFICIENCY):ApplieswhentheobjectiveorrequiredscreeningEFFICIENCYislessthan
thestandardAFACTOR,whichis95%EFFICIENCY.Forexample:ifscalping,youdonotneedtobe
95%efficient,morelike85%ifcompletelyacceptable.lessefficiency=smallerscreenneeded.
SCREENEFFICIENCY:youmustdoublechecktheBEDDEPTHFACTORS....MOSTMOSTCRITICAL
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
6/9
9/28/2016
SelectingScreenSizeandOpenArea
afterarrivingatthewidthvslengthneededfromtheforumulaabove.
HOPINGTHISHELPS..IFMOREQUESTIONS,LETerRIP.GeorgeBakerMODERATOR.
(ItriedtocopymyVSMAFORMULAandmyscannerwasnotcooperating...........so,Itypedallthis
....painful)
Needhelponhowtofindoutscreeningefficiencyandhowitcanberelatedtoscreensizeselection
withrespecttoscreenefficiencyfactor.Whatarethefactorsthatweshouldconsiderforfindingout
theoverallscreeningareaofascreendeck.
WhataretheotherprominentscreeningmodelapartfromKarramodel.
[/QUOTE][/QUOTE]
AttachedThumbnails
BestRegards,
GeorgeBaker
RegionalSalesMgrCanada
TELSMITHInc
Mequon,Wisconsin
15192426664Cell
E:(work)gbaker@telsmith.com
E:(home)gggman353@gmail.com
website:www.telsmith.com
Manufacturerofportable,modularandstationarymineralprocessingequipmentfortheaggregate
andminingindustries.
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
7/9
9/28/2016
SelectingScreenSizeandOpenArea
ReplyWithQuote
#5
16thOctober2013, 12:45
StevieStevenson
Engineer
SvensonConsultants
Heretohelp!
OriginallyPostedbytanmay_tega
Needhelponhowtofindoutscreeningefficiencyandhowitcanberelatedtoscreensizeselection
withrespecttoscreenefficiencyfactor.Whatarethefactorsthatweshouldconsiderforfindingout
theoverallscreeningareaofascreendeck.
WhataretheotherprominentscreeningmodelapartfromKarramodel.
Ifyouwanttosendthroughyourapplicationdetailsthenwecantellyouwhatefficiencyyou
shouldbeabletoachieveonthesizeofmachineyouhave.
Ifyoucansend:
TPH
Material(Sand/Coaletc)
BulkDensity(t/m3)
CutSizeeachdeck(mm)
TypeofDeck(Wire/P.Uetc)
Inclined/Horizontal
Wet/Dry
FeedGrading(%passing)
Manythanks.
ReplyWithQuote
QuickNavigation
Screening&Feeding Top
PreviousThread|NextThread
SimilarThreads
SelectingElbows
ByAuthorinforumWhitepapers/TechnicalArticles/Guidelines
ScreenSizeFormula
ByK.SenthilkumarinforumScreening&Feeding
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
Replies:9
LastPost:28thFebruary2010,14:35
Replies:4
LastPost:24thJuly2008,23:03
8/9
9/28/2016
SelectingScreenSizeandOpenArea
ByK.SenthilkumarinforumScreening&Feeding
CalculationofScreenArea
LastPost:24thJuly2008,23:03
Replies:6
ByvolgeninforumScreening&Feeding
LastPost:2ndJanuary2007,1:01
ScreenArea
Replies:6
ByANUPAMAGARWALinforumScreening&Feeding
LastPost:4thApril2004,19:57
GRIZZLYfeedersectionOPENAREACalc
Replies:0
ByGeorgeBakerinforumScreening&Feeding
LastPost:11thMarch2004,3:14
TagsforthisThread
bed,capacity,coal,deck,density,effective,feed,insert,manufacturers,material,safety,screen,screening,
selection,show,sizing,slurry,standard,troubleshooting,vibra,vibrating,vibratingscreen,water
ViewTagCloud
PostingPermissions
Youmaynotpostnew
threads
Youmaynotpostreplies
Youmaynotpostattachments
Youmaynotedityourposts
BBcodeisOn
SmiliesareOn
[IMG]codeisOn
[VIDEO]codeisOn
HTMLcodeisOn
ForumRules
vB4bulkonline
AlltimesareGMT+1.Thetimenowis1:52.
PoweredbyvBulletinVersion4.2.3
Copyright2016vBulletinSolutions,Inc.Allrightsreserved.
20022012ReinhardH.Whlbier
SingleSignOnprovidedbyvBSSO
http://forum.bulkonline.com/showthread.php?26158SelectingScreenSizeandOpenArea
9/9