OVERVIEW&INSTALLATION
LEDs
Front panel has 3 indication LEDS. LED3 indicates position of DIP switch S1. Color indication of all
LEDs must be ignored in Forced mode (DIP switch S4 in DOWN position).
Load detected and voltage fed at the output
of PoE injector (POWER GOOD)
DIP switches
Back panel has 4 switches in order to operate PoE injector in different modes.
Auto PoE++ mode is factory default; it supports PoE compatible devices only. In case Auto PoE++
mode is enabled, (S1 position DOWN, S4 position UP) Imax mode (PD class) is negotiated
automatically with the device connected.
Appropriate Imax selection while Manual PoE mode is enabled (S1 UP, S4 UP) will provide most
effective surge protection for the radio. In case of exceeding set Imax upper LEDs (LED1&LED2) will
blink in green color.
Connecting device in Manual or Forced modes will introduce approx. 5 second delay of LED
indication.
Position of DIP switches should be changed only while PoE injector is turned off.
Nr.
S1
S2
S3
S4
Description
2
3
4
DIP switch position DOWN, DIP switch position UP, any position
Recommended modes
Integra / Integra-S / Integra-W / Integra-WS* Mode Nr. 1 or 5 (Auto PoE++ or Manual PoE
mode. Imax= auto or Imax=1700mA);
CFIP Lumina FODU Mode Nr. 5 (Manual PoE mode. Imax=1700mA);
SAF FreeMile 5.8 MIMO / SAF FreeMile 17 / SAF FreeMile 24 Mode Nr. 2 (Manual PoE mode.
Imax=750mA.);
SAF FreeMile 5 GE MIMO Mode Nr. 1 (Auto PoE++ mode. Imax= auto.);
CFIP-106 / CFIP-108 Mode Nr. 4 (Manual PoE mode. Imax=1250mA).
*
depending on HW revision
Electrical specification
Data rate
Auto PoE++ mode
Manual PoE mode
Input Voltage
Output Voltage
Max Output Current in Auto PoE++ mode**
Switchable Current limits in PoE Manual modes
Up to 1000 Mb/s
Green indicator LED*
Blue indicator LED*
20 65 V**
54 V
1.2 A (2236V DC), 1.6 A (3660V DC)
0.75, 1.0, 1.25 and 1.7A
2.0 A
2ESDV-02P with screw locks
Shielded RJ45 jacks
Pins (1, 2), (3, 6), (4, 5) and (7, 8)
+ (1, 2) and (4, 5); - (3, 6) and (7, 8)
+/- 70 V
100 m
* Color indication can be disregarded in Forced mode (DIP S4 position DOWN), will indicate only Power ON.
** Max Output current value drops if Input Voltage is under 36V
Mechanical specification
Ports
Dimensions (W/H/D):
Weight
Enclosure
Operating Temperature
Mounting
** 2ESDV-02P plug with screw locks included.
-RJ45 - Data
-RJ45 - Data + Power
-DC - 2ESDV-02P socket with screw locks**
-Grounding screw
82 mm/41 mm/154 mm
0.4 kg
Steel
-10C to + 50C
-With bracket (included)
-19 rack mounting shelf (p/n I0KTPI11.003)
-DIN-rail clip (p/n I0STPI11.01)