Sei sulla pagina 1di 12

Custom Telecom Cabinet Solutions

Whatever you want to say here.

Modular Cabinet Solutions

About Raycap
Raycap is a privately-held technology
solutions provider offering products and
services that support and protect the
worlds critical telecommunications, energy,
transportation and other infrastructure.
Since 1987 Raycap has built a worldwide
organization with offices and production
facilities throughout Europe and in North
America. The company combines advanced
engineering, superior product design,
systems integration and manufacturing
capability with a deep understanding of
the needs of the customer to create unique
technological solutions for mission-critical
applications. It also offers engineering
services such as custom product design
and site surveys, as well as warehousing,
logistics, customer training, and much more.

Modular Cabinet Solutions

Our comprehensive understanding of


customers needs and the industries they
operate in is crucial to our ability to develop
effective products and solutions.
Raycap is known for integrating the latest
technology with the highest quality of
service. The companys team of talented,
highly experienced staff works together with
customers to find the best-fit solutions. As a
result, more than 50% of products delivered
are custom-built for specific customer
applications and to their specifications. From
rigorous internal and independent testing to
a consultative customer-focused approach
and industry-leading product warranty,
Raycap is determined to deliver the highest
quality product with responsiveness,
innovation and agility.

MODULAR

DES IG N

FO R

MA X IMU M

F L E X I B I L I T Y

RCAB-OD-9367
Outdoor Cabinet for
Active Equipment

Environmental & Mechanical Specifications*


Protection Class

IP55

Impact Protection

IK10

Operating Temperature

-45C to +45C (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature

-25C to +55C (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature

-40C to +70C (according to ETSI 300 019-1-2, Class 2.3)

Acoustic Noise Level

55dB (A) @1m

Earthquake

Zone 4

Mechanical
Construction

Aluminum alloy

Surface

Powder coated, RAL 7035

Dimensions

1430mm (H) x 1652mm (W) x 540mm (D)

Reserved for PSU with DC Distribution

1U 19" (extra 1U for DC terminals)

Reserved for ODF

1U

Reserved for AC PDU

3U

Free User Space

10U 19"

Locking Mechanism

3-point system

Cable Entry Point

Bottom

Temperature Control
Cooling System

Heat exchanger 60W/K

Heater

Included

Sensors
Door Alarm Contact

Included

Smoke Sensor

Included

Temperature

Included

Flood Sensor

Included

* Modifications according to customer's requests are possible.


1690

90

575

1261

Dual wall aluminum


Robust design
Modular design
Easy installation
process
Solid profile technology
Excellent heat
dissipation
19 technology with
moving frames
Cooling capacity by
using heat exchanger
Customer specific
integrations
Left and Right Type
available, depending
on the installation site

Environmental

80

The RCAB-OD-9367
is an outdoor cabinet
system that provides
maximum protection of
customers equipment
against vandalism
and extreme weather
conditions. This cabinet
is the ideal solution for
installations over existing
cross connect cabinets in
parallel with the hosting
of active and passive
telecom equipment.

480

1595

539,5

1652

Modular Cabinet Solutions

MODULAR

DES IG N

FO R

MA X IMU M

F L E X I B I L I T Y

RCAB-OD-6849
Outdoor Cabinet for
Active Equipment

Environmental & Mechanical Specifications*


The RCAB-OD-6849 is an
outdoor cabinet system
that provides maximum
protection of customers
equipment against
vandalism and extreme
weather conditions. Due
to its small dimensions,
the cabinet is the ideal
solution for installations in
residential areas.

Environmental

Dual wall aluminum


Robust design
Modular design
Easy installation
process
Solid profile technology
Excellent heat
dissipation
19 technology with
moving frames
Cooling capacity by
using heat exchanger
Customer specific
integrations

Dimensions

1520mm (H) x 1188mm (W) x 430mm (D)

Reserved for PSU with DC Distribution

1U 19" (extra 1U for DC terminals)

Reserved for ODF

1U

Reserved for AC PDU

3U

Free User Space

10U 19"

Locking Mechanism

3-point system

Cable Entry Point

Bottom

Protection Class

IP55

Impact Protection

IK10

Operating Temperature

-45C to +45C (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature

-25C to +55C (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature

-40C to +70C (according to ETSI 300 019-1-2, Class 2.3)

Acoustic Noise Level

55dB (A) @1m

Earthquake

Zone 4

Mechanical
Construction

Aluminum alloy

Surface

Powder coated, RAL 7035

Temperature Control
Cooling System

Heat exchanger 60W/K

Heater

Included

Sensors
Door Alarm Contact

Included

Smoke Sensor

Included

Temperature

Included

Flood Sensor

Included

* Modifications according to customer's requests are possible.


1198,2

180

444

1333

8,7

Modular Cabinet Solutions

429,5

1188

RCAB-OD-8040
Outdoor Cabinet for
Active & Passive
Equipment

Environmental & Mechanical Specifications*


The RCAB-OD-8040 is
a modular double-wall
multifunctional cabinet
that provides maximum
protection of customer's
equipment against
vandalism and extreme
weather conditions. This
cabinet with cooling
technology is installed
outdoors and is the
ideal solution for hosting
demanding and sensitive
active and passive
equipment.

Environmental

Double wall aluminum


Robust design
100% modular design
Cabinet parts are
replaceable without
service interrruption
Excellent passive heat
conductivity
Cooling system
including heat
exchanger
Customer specific
integrations

Dimensions

1700mm (H) x 1450mm (W) x 500mm (D)

Plinth

Stainless steel, 4 adjustable leveling feet

Plastics

DIN ISO 11469; Marking of plastic products

Noise Level

TA Alarm (Technical Directive on Noise Pollution Control)

Protection Class

IP54

Resistance Class

RC2

Operating Temperature

-33C to +45C (according to ETSI 300 019-1-4, Class 4.1)

Storage Temperature

-33C to +45C (according to ETSI 300 019-1-1, Class 1.3)

Transportation Temperature

-40C to +70C (according to ETSI 300 019-1-2, Class 2.3)

Mechanical
Construction

Aluminum

Surface

Powder coated, RAL 7035

Racks

1x19"/ETSI 38 SU, 1xTelecom rack

Locking Mechanism

3-point locking system

Doors

2 with door stopper


1x Swivel handle, locking system Deutsche Telekom

Cable Entry

1x Universal foam in MDF area,


1x Splitted cable entry plate with grommet in ETSI rack area

Temperature Control
Cooling System

Heat exchanger 60W/K

Sensors
Temperature Sensor

Included

* Modifications according to customer's requests are possible.

500

1450

1700

Modular Cabinet Solutions

MODULAR

DES IG N

FO R

MA X IMU M

F L E X I B I L I T Y

RCAB-OD-1657
Outdoor Cabinet for
Active Equipment

Environmental & Mechanical Specifications*


The RCAB-OD-1657 is an
outdoor cabinet system
that provides maximum
protection of customers
equipment against
vandalism and extreme
weather conditions.
This cabinet is the ideal
solution for installations
hosting active and
passive telecom
equipment.

Protection Class

IP55

Impact Protection

IK10

Operating Temperature

-45C to +45C (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature

-25C to +55C (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature

-40C to +70C (according to ETSI 300 019-1-2, Class 2.3)

Acoustic Noise Level

55dB (A) @1m

Earthquake

Zone 4

Mechanical
Construction

Double Aluminum alloy

Surface

Powder coated, RAL 7035

Dimensions

1295mm (H) x 790mm (W) x 650mm (D)

Reserved for PSU with DC Distribution

1U 19" (extra 1U for DC terminals)

DC to AC Inverter 400W

Included

AC PDU

Included

MDF

Space for 20x10 LSA PLUS, 2x64 Splitter Modules

Free User Space

6U 19"

Locking Mechanism

3-point system

Cable Entry Point

Bottom

Temperature Control
Cooling System

Heat exchanger 40W/K

Heater

Included

Sensors
Door Alarm Contact

Included

Smoke Sensor

Included

Temperature

Included

Flood Sensor

Included

* Modifications according to customer's requests are possible.

80

1120

95

Dual wall aluminum


Robust design
Modular design
Easy installation
process
Solid profile technology
Excellent heat
dissipation
19" technology with
moving frames
Cooling capacity by
using heat exchanger
Customer specific
integrations

Environmental

Modular Cabinet Solutions

732

592

790

650

RCAB-OD-1171
Outdoor Cabinet for
Active Equipment

Environmental & Mechanical Specifications*


The RCAB-OD-1171 is an
outdoor cabinet system
that provides maximum
protection of customers
equipment against
vandalism and extreme
weather conditions.
This cabinet is the ideal
solution for installations of
active & passive telecom
equipment.

Environmental

Dual wall aluminum


Robust design
Modular design
Easy installation
process
Solid profile technology
Excellent heat
dissipation
ETSI technology with
moving frames
Cooling capacity by
using heat exchanger
Customer specific
integrations
Left and Right Type
available, depending
on the installation site

Protection Class

IP55

Impact Protection

IK10

Operating Temperature

-45C to +45C (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature

-25C to +55C (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature

-40C to +70C (according to ETSI 300 019-1-2, Class 2.3)

Acoustic Noise Level

55dB (A) @3m

Earthquake

Zone 4

Mechanical
Construction

Double Aluminum alloy

Surface

Powder coated, RAL 7035

Dimensions

1503mm (H) x 1720mm (W) x 637mm (D)

Reserved for PSU with DC Distribution

5U

Reserved for ODF

1U

Reserved for AC PDU

3U

Free User Space

2x24U ETSI Rack

Locking Mechanism

3-point system

Cable Entry Point

Bottom

Temperature Control
Cooling System

Heat exchanger 80W/K

Heater

Included

Sensors
Door Alarm Contact

Included

Smoke Sensor

Included

Temperature

Included

Flood Sensor

Included

* Modifications according to customer's requests are possible.


637

1770

80

80

916.5

1323

1423

406.5

100

637

594

1677

594

637

1720

637

Modular Cabinet Solutions

M ODUL AR

DESIG N

FO R

MA X IMU M

F L E X I B I L I T Y

RCAB-OD-2027
Outdoor Cabinet for
Active Equipment

The RCAB-OD-2027 is an
outdoor cabinet system
that provides maximum
protection of customers
equipment against
vandalism and extreme
weather conditions. This
cabinet is the ideal solution
for installations of active and
passive telecom equipment.

Environmental & Mechanical Specifications*

Dual wall aluminum


Robust design
Modular design
Easy installation
process
Solid profile technology
Excellent heat
dissipation
19 technology with
moving frames
Cooling capacity by
using heat exchanger
Customer specific
integrations
Left and Right Type
available, depending
on the installation site

Environmental
Protection Class

IP55

Impact Protection

IK10

Operating Temperature

-45C to +45C (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature

-25C to +55C (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature

-40C to +70C (according to ETSI 300 019-1-2, Class 2.3)

Acoustic Noise Level

55dB (A) @3m

Earthquake

Zone 4

Mechanical
Construction

Double Aluminum alloy

Surface

Powder coated, RAL 7035

Dimensions

1640mm (H) x 1480mm (W) x 546mm (D)

Reserved for PSU with DC Distribution

2U 19"

Reserved for ODF

1U

Reserved for AC PDU

3U

Free User Space

10U 19"

Locking Mechanism

3-point system

Cable Entry Point

Bottom

Temperature Control
Cooling System

Heat exchanger 80W/K

Heater

Included

Sensors
Door Alarm Contact

Included

Smoke Sensor

Included

Temperature

Included

Flood Sensor

Included

* Modifications according to customers requests are possible.


638,63
1481

80

1641

546

Modular Cabinet Solutions

448

1383

507,74

1440,77

RHEX-9790
Heat Exchanger for
Outdoor Cabinet

Technical Specifications*
Raycaps Heat Exchanger
solutions ensure that
active electronic
equipment installed in
outdoor cabinets are
cooled properly, are
isolated from dust and
dirt and keep the noise
level low.
They provide excellent
thermal performance,
optimized controlling and
have low maintenance
requirements.

Heat Exchanger
Supply Voltage Nominal

-48 VDC

Power Consumption (max)

77W

Current (max)

1.6A

Operating Temperature Range

-33C to +60C

Cooling Capacity

60W/K

IP Rating (Cabinet Installation)

IP 55

Speed

565 m3/h

Technical Features

Control input 0-10 VDC/PWM, tach output

EMC Interface Immunity

EN 61000-6-2

EMC Interface Emission

EN 61000-6-3

Housing Material

Aluminum 1.5mm

Mounting Position

Roof / Door

Fan Speed Controller


Mounting Position

Cabinet / Heat Exchanger housing

Programmable Fan Speed Control

Included

Fan Alarm

Included

* Modifications according to customer's requests are possible.

Hot Air

External Air Flow

Internal Air Flow

Hex
Core
Cold Air

380

door-mounted configuration

door-mounted

roof-mounted
103,50
292

146

External Air Flow


Cold Air

Hot Air

886

Internal Air Flow

965

Hex
Core

roof-mounted configuration

Modular Cooling Solutions

MODULAR

DES IG N

FO R

MA X IMU M

F L E X I B I L I T Y

RHEX-2868
Heat Exchanger for
Outdoor Cabinet

Technical Specifications*
Raycaps Heat Exchanger
solutions ensure that active
electronic equipment
installed in outdoor cabinets
are cooled properly, are
isolated from dust and dirt
and keep the noise level low.

Heat Exchanger

They provide excellent


thermal performance,
optimized controlling and
have low maintenance
requirements.

Hot Air

External Air Flow

Internal Air Flow

Supply voltage nominal

-48 VDC

Power consumption (max)

77W

Current (max)

1.6A

Operating Temperature range

-25C to +70C

Cooling capacity

max 60W/K (depending on the selected fan speed)

IP Rating (cabinet installation)

IP55

Speed

3050 min-1

Noise Level

min 35dB (A) - max 60 dB (A) @1m

Number of fans

Insulation Class

"B"

Technical features

Control input 0-10 VDC/PWM, tach output

EMC Interface Immunity

EN 61000-6-2

EMC Interface Emission

EN 61000-6-3

Housing Material

Aluminum 1.5mm

Mounting Position

Roof

Dimensions

854mm (H) x 140mm (W) x 347mm (D)

Fan Speed Controller

Hex
Core
Cold Air

Mounting position

Cabinet / Heat Exchanger housing

Programmable fan speed control

Included

Fan Failure Alarm

Included

Temperature Alarm

Included

* Modifications according to customers requests are possible

door-mounted configuration

.
External Air Flow
Cold Air

140

Hot Air

40

854

Hex
Core

180

312

347

4x

Internal Air Flow

842

800

roof-mounted configuration
THIRD ANGLE PROJECTION

TOLERANCES

DESCRIPTION

Heat Exchanger, Rooftop, DT street cab.

10

Modular Cooling Solutions

Raycap Worldwide Locations


Raycap GmbH
Parkring 11
85748 Garching Munich
Germany

Raycap Corporation SRL


Soseaua de Centura 27-28
077040 Chiajna Ilfov
Romania

Raycap S.A.
Telou & Petroutsou 14
15124 Maroussi Athens
Greece

Raycap Cyprus Ltd.


46 Lefkosias Street
Industrial Area of Dali
2540 Nicosia
Cyprus

Raycap S.A. Manufacturing


Industrial Area of Drama
66100 Drama
Greece
Raycap Inc.
806 South Clearwater Loop
Post Falls, ID 83854
United States of America

Iskra Zaite d.o.o.


Stegne 23 A
1000 Ljubljana
Slovenia
Raycap (Suzhou) Co. Ltd.
Block B, Phase II
of New Sea Union
No. 58 Heshun Road
SIP, Suzhou 215122
Jiangsu Province
China

www.raycap.cominfo@raycap.com

2016 Raycap All rights reserved.


G09-00-105160628

Potrebbero piacerti anche