Sei sulla pagina 1di 28

LZM1-4 circuit-breaker series up to 1600 A

Circuit Breakers LZM

The power of fusion.


Brand inception dates:

1874

1886

1893

1899

1906

1908

1911

1934

1962

1963

1976

1983

1990

Theres a certain energy at Eaton. Its the power of


uniting some of the worlds most respected names to
build a brand you can trust to meet your every power
management need. The energy created supports our
commitment to powering business worldwide.
From power distribution to power quality and control,
Eaton allows you to proactively manage your complete
power system by providing electrical solutions that
safe. Visit Eaton.com/electrical.

All of the above are trademarks of Eaton Corporation or its affiliates. Eaton has
a license to use the Westinghouse name in Asia Pacific. 2010 Eaton Corporation.

1999

Circuit-breakers LZM
Contents

Circuit-breakers LZM

1.1System overview
1
....................................................................................................................1
Circuit-breakers
1.2Technical overview
Circuit-breakers, 3/4-pole ...........................................................................................................4
1.3Ordering
Circuit-breaker thermo-magnetic release, 3-pole ........................................................................6
Circuit-breaker, magnetic short-circuit releases, 3 pole ..............................................................8
Circuit-breaker thermo-magnetic release, 4-pole ...................................................................... 10
Circuit-breaker thermo-magnetic release, 4-pole ...................................................................... 12
Circuit-breakers, electronic releases, 4 pole ............................................................................. 14
1.4 Engineering
Sizes 1, 2: tripping characteristics ............................................................................................ 16
Sizes 2, 3: tripping characteristics ............................................................................................. 17
Sizes 3, 4: tripping characteristics ............................................................................................. 18
Frame size 1: let-through characteristics .................................................................................. 19
Frame size 2: let-through characteristics .................................................................................. 20
Sizes 1, 3: let-through characteristics ....................................................................................... 21
Sizes 2, 3: let-through characteristics ....................................................................................... 22
1.5 Dimensions
..................................................................................................................... 23
Size 1: basic units
Size 2: basic units ..................................................................................................................... 24
Size 3: basic units ..................................................................................................................... 25

Circuit-breakers
LZM 1, 2, 3, 4 up to 1600 A
Reliably and safely controlling,
switching and managing power,
in industry, in buildings and in
machine construction. Enabled
by innovative protection
concepts.

Circuit-breaker series
LZM1 to LZM4

just 4 compact frame sizes


available as 3 and 4-pole device
now also up to 1600 A
flexible mounting using
modular function groups
full rated current at 50 C
ambient temperature
switch suitable for world-wide
use

Page 6

Circuit-breakers LZM June 2011

1.1
1

Circuit-breakers LZM
System overview

Circuit-breakers LZM

8
9

25

10
3
2

1
24
11

13

12

14

23

19
20

24

16
15

21
17

24
24
24

18

24
24

Circuit-breakers LZM June 2011

Circuit-breakers LZM
System overview

Basic units
Circuit-breaker

Rated uninterrupted current up to 1600 A


Switching capacity 25, 36, 50, 70kA at 415V
Adjustable releases for overload and shortcircuit
Adjustable time selectivity
Earth-fault protection
Protection of systems, cables, motors,
generators
3 and 4 pole versions,IEC/EN60947, CCC
D page6

Add-on functions
1

Standard auxiliary contact (HIN)

Mounting accessories
13

Control circuit terminal

13

For two terminals at top or bottom


LZM1 D page23
LZM2 D page27
LZM3 D page31

Switching with the main contacts. Used for


indication and interlock functions.
D page42
Trip-indicating auxiliary contact (HIA)

General trip indication '+', when tripped by


voltage release, overload release or shortcircuit release
D page42
Early-make auxiliary contacts

Tunnel terminals for Al and Cu cable

24

For interlocking and load shedding circuits, as


well as for early makeof the undervoltage
release in main switch/Emergency-stop
applications
D page42
Voltage release

24

25

Rear drive

D page60
Door coupling rotary handle

Lockable
With door interlock
D page54
Main switch rotary handle for side panel
mounting

16,
18

15

Extension shaft

17

Can be cut to required length.


D page54
Rotary handle

Remote operator

19

22

For remote switching of circuit-breakers and


switch-disconnectors
D page64
Toggle lever interlock device

D page61

Clip plate

10

NZM1-XC35 for 35 mm top-hat rail


NZM2-XC75 for 75 mm top-hat rail
a page61
11

LZM1 D page21
LZM2 D page25
LZM3 D page31
Plug-in and withdrawable unit

Lockable
D page56

LZM1 D page23
LZM2 D page27
LZM3 D page32

Rear connection

D page58

Protection against direct contact where cable


lugs, busbars or tunnel terminals are used
LZM1 D page23
LZM2 D page27
LZM3 D page32
Terminal cover, knockout

14

Standard version of frame size 1 assembled


within the circuit-breaker enclosure
LZM1 D page21
LZM2 D page25
LZM3 D page29
Terminal cover

D page49

1
8

Standard with control circuit terminal


LZM1 D page21
LZM2 D page25
LZM3 D page31
Box terminals

Undervoltage release
Non-delayed
OFF-delayed
Shunt release
D page44
Delay unit for under voltage release

1.1

D page40
21
For use with toggle lever, rotary drive and
remote operator protruding from the enclosure
D page61
Insulating surround

External warning plate/designation label

20

D page60
Spacer

23

12

D page61
IP2X protection
against contact with a finger

For box terminals


LZM1 D page23
LZM2 D page27
LZM3 D page32
IP2X protection
against contact with a finger

For barrier
LZM1 D page23
LZM2 D page27
LZM3 D page32
Circuit-breakers LZM September 2011

1.2
1

Circuit-breakers LZM
Technical overview

Circuit-breaker, 3/4-pole LZM1, LZM2, LZM3, LZM4


Circuit-breaker
With main switch characterist ics to IEC/EN 60204 and isolating
characteristics to IEC/EN60947, CCC

Rated uninterrupted current Iu = Rated current In


Adjustable overload release Ir
Adjustable short-circuit release Ii
Delayed short-circuit release Isd

Ambient temperature at 100% Iu min./max. -25 / +50 C

Basic switching capacity

400/415 V
440 V

Notes

Ir
A

Ii
A

20
25

20
25

0.8 1 x In

350

0.8 1 x In

350

32

32

0.8 1 x In

350

40

40

0.8 1 x In

8 10 x In

50
63
80

50
63
80

0.8 1 x In
0.8 1 x In
0.8 1 x In

6 10 x In
6 10 x In
6 10 x In

100

100

0.8 1 x In

6 10 x In

125

125

250

0.8 1 x In

6 10 x In

160

160

320

0.8 1 x In

LZM1: 8 x In, 6 10 x In

200
250
300

400
500

0.8 1 x In
0.8 1 x In
0.8 1 x In

LZM1: 8 x In, 6 10 x In
LZM1: 8 x In, 6 10 x In
LZM1: 8 x In, 6 10 x In

LZMB1-A...

LZMB2-A...

25
25

kA/cos
kA/cos
kA/cos
kA/cos

36
30
12
8

LZMN1-A...

LZMN2-A...

LZMN3-A...

kA/cos
kA/cos
kA/cos
kA/cos

50
35
20
10

50
35
25
20

50
35
25
20

0.25
0.25

kA/cos
kA/cos
kA/cos
kA/cos

0.25
0.25

LZMC2-A...

LZMC1-A...

Strong switching capacity

400/415 V
440 V
525 V
690 V

Iu
A

25
25

Normal switching capacity

400/415 V
440 V
525 V
690 V

Iu
A

kA/cos
kA/cos

Comfort switching capacity

400/415 V
440 V
525 V
690 V

Thermomagnetic releases
System and cable protection

0.25
0.25
0.5
0.5
0.25
0.25
0.30
0.50

36
30
12
8

LZMC3-A...

0.25
0.25
0.5
0.5
0.25
0.25
0.25
0.30

36
30
12
8

0.25
0.25
0.5
0.5
0.25
0.25
0.25
0.30

LZMS1-A-...

LZMS2-A-...

LZMS3-A-...

70
35
20
10

70
65
36
20

70
65
36
25

0.20
0.25
0.30
0.50

0.20
0.20
0.25
0.30

0.20
0.20
0.25
0.30

The stated switching capacity values are rated ultimate short-circuit breaking capacities ( Icu )

24

Circuit-breakers LZM September 2011

1.2

Circuit-breakers LZM
Technical overview

Magnetic short-circuit release

Electronic releases

Motor protection

Systems, cable, selectivity and generator


protection

Iu
A

Iu
A

Iu
A

Ii
A

Iu
A

Iu
A

Ir
A

Isd
A

Ii
A

400

0.5 1 x In
0.5 1 x In

2 10 x Ir
2 10 x Ir

2 12 x In
2 12 x In

630

0.5 1 x In

2 10 x Ir

2 12 x In

40

8 14 x In

630

0.5 1 x In

2 10 x Ir

2 12 x In

50
63
80

8 14 x In
8 14 x In
8 14 x In

630
630

0.5 1 x In

2 10 x Ir
2 6 x Ir

2 12 x In
2 8 x Ir

100
100

125

250

100

160

320

100
100

200

400
500

LZMB1-S...

LZMB2-S...

25
25

25
25

0.25
0.25

0.25
0.25

LZMC1-S...

LZMC2-S...

LZMC3-S...

36
30
12
8

36
30
12
8

36
30
12
8

0.25
0.25
0.50
0.50

LZMN1-S...

50
35
20
10

0.25
0.25
0.30
0.50

LZMS1-S-...

70
35
20
10

0.20
0.25
0.30
0.50

0.25
0.25
0.25
0.50

0.25
0.25
0.25
0.50

LZMN2-S...

LZMN3-S...

LZMN3-...E...

50
35
25
20

50
35
25
20

50
35
25
20

0.25
0.25
0.25
0.30

0.25
0.25
0.25
0.30

0.25
0.25
0.25
0.30

LZMS2-S...

LZMS3-S...

LZMS3-...E...

70
65
36
20

70
65
36
25

70
65
36
25

0.20
0.20
0.25
0.30

0.20
0.20
0.25
0.30

0.20
0.20
0.25
0.30

Circuit-breakers LZM September 2011

1.3
1 Terminals standard,
terminal screws as
accessories

Circuit-breakers LZM
Ordering

Circuit-breaker, thermo-magnetic release, 3 pole LZM...1, LZM...2, LZM...3


Protection of systems and cables

Rated current =
rated uninterrupted
current
In = Iu
A

Basic switching capacity 25 kA


at 415 V 50/60 Hz

Setting range

Overload releasesShort-circuit releases


Ir
Ii
A
A

Part no.

Article no.

Price

see price
list

Comfort switching capacity 36 kA


at 415 V 50/60 Hz
Part no.

Article no.

Price

see price
list

I
3 pole

Terminal screws
standard, terminals
as accessories

20

1520

350

LZMB1-A20

LZMC1-A20

25

2025

350

LZMB1-A25

LZMC1-A25

32

2532

350

LZMB1-A32

LZMC1-A32

40

3240

320400

LZMB1-A40

50

4050

63

109233

109234

109432

109433
109434

LZMC1-A40

109235

109435

300500

LZMB1-A50

LZMC1-A50

5063

380630

LZMB1-A63

109237

109437

80

6380

480800

LZMB1-A80

LZMC1-A80

100

80100

6001000

LZMB1-A100

LZMC1-A100

125

100125

7501250

LZMB1-A125

LZMC1-A125

160

125160

1280

20

1520

350

25

2025

350

32

2532

350

40

3240

320400

50

4050

300500

63

5063

380630

80

6380

480800

100

80100

6001000

125

100125

7501250

160

125160

200

109236

109238

109239

109430

LZMB1-A160

109436

LZMC1-A63

109438

109439
109440

LZMC1-A160

109431

109441

9601600

LZMB2-A160

LZMC2-A160

160200

12002000

LZMB2-A200

250

200250

15002500

300

240300

15002500

250

200250

15002500

320

250320

19203200

400

320400

24004000

500

400500

30005000

Notes
6

109232

Notes for terminals D 21

Circuit-breakers LZM September 2011

109522

109526

LZMC2-A200

109523

109527

LZMB2-A250

LZMC2-A250

LZMB2-A300

LZMC2-A300

109524

109525

109528
109529

LZMC3-A250

109597

LZMC3-A320

109598

LZMC3-A400

109599

LZMC3-A500

109600

24

Circuit-breakers LZM
Ordering

1.3
1

Normal switching capacity 50 kA


at 415 V 50/60 Hz

Strong switching capacity 70 kA


at 415 V 50/60Hz

Part no.

Part no.

Article no.

LZMN1-A20

109442

LZMN1-A25

109443

LZMN1-A32

Price

see price list

Article no.

LZMS1-A20

109452

LZMS1-A25

109453

LZMS1-A32

109444

109454

LZMN1-A40

LZMS1-A40

LZMN1-A50

LZMS1-A50

LZMN1-A63

LZMS1-A63

LZMN1-A80

LZMS1-A80

LZMN1-A100

LZMS1-A100

109445
109446
109447

109448

109449

LZMN1-A125

109455
109456

see price list

IEC/EN 60947-2
Adjustable overload releases I r
0.8 1 x I n (ex-works 0.8 x I n )
Adjustable short-circuit releases I i
6 10 x I n (ex-works 6 x I n)
LZM...-A40: 8 10 x I n (ex-works 8 x I n)
Fixed short-circuit release I i
350 A at I n = 20 32 A
1280 A at I n = 160 A (LZM1)
Std. pack 1 off

109457
109458
109459

LZMS1-A125

109450

109460

LZMN1-A160

LZMS1-A160

109451

Price

109461

LZMS2-A20

109534

LZMS2-A25

109535

LZMS2-A32

109536

LZMS2-A40

109537

LZMS2-A50

109538

LZMS2-A63

109539

LZMS2-A80

109540

LZMS2-A100

109541

LZMS2-A125

109542

LZMN2-A160

LZMS2-A160

LZMN2-A200

LZMS2-A200

109530
109531

LZMN2-A250

109543
109544

LZMS2-A250

109532

109545

LZMN2-A300

LZMS2-A300

LZMN3-A250

LZMS3-A250

LZMN3-A320

LZMS3-A320

LZMN3-A400

LZMS3-A400

LZMN3-A500

LZMS3-A500

109533
109601

109602
109603
109604

109546

109605

109606
109607
109608

Circuit-breakers LZM September 2011

1.3
1 Terminals standard,
terminal screws as
accessories

Circuit-breakers LZM
Ordering

Circuit-breaker, magnetic short-circuit releases, 3 pole LZM...1, LZM...2, LZM...3


Short-circuit protection
Motor protection in conjunction with overload relay

With short-circuit release


Without overload release
Rated current =
rated uninterrupted
current
In = Iu
A

Setting range

Short-circuit
releases
Ii
A

Motor rating
AC-3 at 400 V
50/60 Hz
P
kW

Rated
operational
current AC-3
at 400 V
50/60 Hz
Ie

Basic switching capacity


25 kA at 415 V 50/60 Hz
Part no.

Article no.

Price

see price
list

Comfort switching capacity


36 kA at 415 V 50/60 Hz
Part no.

Article no.

I
3 pole

Terminal screws
standard, terminals
as accessories

40

320560

18.5

36

LZMB1-S40
109462

LZMC1-S40
109467

50

400700

22

41

LZMB1-S50
109463

LZMC1-S50
109468

63

504882

30

55

LZMB1-S63
109464

LZMC1-S63
109469

80

6401120

37

68

LZMB1-S80
109465

LZMC1-S80
109470

100

8001250

55

99

LZMB1-S100
109466

LZMC1-S100
109471

40

320560

18.5

36

50

400700

22

41

63

504882

30

55

80

6401120

37

68

100

8001400

55

99

125

10001750

55

99

LZMB2-S125
109547

LZMC2-S125
109550

160

12802240

75

134

LZMB2-S160
109548

LZMC2-S160
109551

200

16002500

110

196

LZMB2-S200
109549

LZMC2-S200
109552

250

20003500

250

LZMC3-S250
109609

320

25604480

320

LZMC3-S320
109610

400

28005000

400

LZMC3-S400
109611

500

30005000

450

LZMC3-S500
109612

Notes

Notes for terminals D 21

Circuit-breakers LZM September 2011

Price

see price
list

Circuit-breakers LZM
Ordering

1.3
1

Normal switching capacity 50 kA


at 415 V 50/60 Hz
Part no.

Article no.

LZMN1-S40
109472
LZMN1-S50
109473
LZMN1-S63
109474
LZMN1-S80
109475
LZMN1-S100
109476

LZMN2-S125
109553
LZMN2-S160
109554
LZMN2-S200
109555
LZMN3-S250
109613
LZMN3-S320
109614
LZMN3-S400
109615
LZMN3-S500
109616

Price

see price list

Strong switching capacity 70 kA


at 415 V 50/60Hz
Part no.

Article no.

LZMS1-S40
109477
LZMS1-S50
109478
LZMS1-S63
109479
LZMS1-S80
109480
LZMS1-S100
109481
LZMS2-S40
109556
LZMS2-S50
109557
LZMS2-S63
109558
LZMS2-S80
109559
LZMS2-S100
109560
LZMS2-S125
109561
LZMS2-S160
109562
LZMS2-S200
109563
LZMS3-S250
109617
LZMS3-S320
109618
LZMS3-S400
109619
LZMS3-S500
109620

Notes

Price

see price list

IEC/EN 60947-4-1 and IEC/EN 60947-2


The circuit-breaker fulfills all requir ements for AC-3 switching category.
Adjustable short-circuit releases Ii
8 14 x In (ex-works 12 x In )
LZM...1-S100, LZM...2-S200: 8 12.5 x In (ex-works 12 x In )
Without overload release Ir
LZM...3-S400: 7 12.5 x In
LZM...3-S500: 6 10 x In
Selection

of circuit-breakers without overload release when combining with ZEV electronic motor-protective relay:
The tripping response of the ZEV motor-protec tive relay is matched by setting of the
tripping class (CLASS), to the starting behaviour of the motor to be protected.
I n in A

Maximum permissible tripping class CLASS

LZM...1-S...4030

5030
6330
8020
10015
LZM...2-S...4030

5030
6330
8030
10030
12530
16020
20010
LZM...3-S...25030

32030
40030
50020

Tripping class

Tripping Tp time with load on all poles of 7.2 times


current setting value

10 A
10
20
30

2s<
4s<
6s<
9s<

Tp F
Tp F
Tp F
Tp F

10 s
10 s
20 s
30 s

Motor-starter combination of classification ty pes 1 and 2 can be found in the Fuseless


motor-starter combinations section of the Main Catalogue.
Std. pack 1 off

Circuit-breakers LZM September 2011

1.3
1 Terminals standard,
terminal screws as
accessories

Circuit-breakers LZM
Ordering

Thermomagnetic release, 4 pole LZM...1


Rated current =
rated uninterrupted
current
In = Iu
A

Setting range

Overload releases
Main pole
Ir
A

Neutral
conductor
Ir
A

Short-circuit
releases

Basic switching capacity


25 kA at 415 V 50/60 Hz
Part no.

Article no.

Ii
A

Price

see price
list

Comfort switching capacity


36 kA at 415 V 50/60 Hz
Part no.

Article no.

I
4 pole

20

1520

1520

350

25

2025

2025

350

32

2532

2532

350

40

3240

3240

320400

50

4050

4050

300500

63

5063

5063

380630

80

6380

6380

480800

100

80100

80100

6001000

125

100125

100125

7501250

160

125160

125160

1280

Notes

10

Notes for terminals D 21

Circuit-breakers LZM September 2011

LZMB1-4-A20
109482
LZMB1-4-A25
109483
LZMB1-4-A32
109484
LZMB1-4-A40
109485
LZMB1-4-A50
109486
LZMB1-4-A63
109487
LZMB1-4-A80
109488
LZMB1-4-A100
109489
LZMB1-4-A125
109490
LZMB1-4-A160
109491

LZMC1-4-A20
109492
LZMC1-4-A25
109493
LZMC1-4-A32
109494
LZMC1-4-A40
109495
LZMC1-4-A50
109496
LZMC1-4-A63
109497
LZMC1-4-A80
109498
LZMC1-4-A100
109499
LZMC1-4-A125
109500
LZMC1-4-A160
109501

Price

see price
list

Circuit-breakers LZM
Ordering

1.3
1

Normal switching capacity 50 kA


at 415 V 50/60 Hz
Part no.

Article no.

LZMN1-4-A20
109502
LZMN1-4-A25
109503
LZMN1-4-A32
109504
LZMN1-4-A40
109505
LZMN1-4-A50
109506
LZMN1-4-A63
109507
LZMN1-4-A80
109508
LZMN1-4-A100
109509
LZMN1-4-A125
109510
LZMN1-4-A160
109511

Price

see price list

Strong switching capacity 70 kA


at 415 V 50/60Hz
Part no.

Article no.

LZMS1-4-A20
109512
LZMS1-4-A25
109513
LZMS1-4-A32
109514
LZMS1-4-A40
109515
LZMS1-4-A50
109516
LZMS1-4-A63
109517
LZMS1-4-A80
109518
LZMS1-4-A100
109519
LZMS1-4-A125
109520
LZMS1-4-A160
109521

Notes

Price

see price list

IEC/EN 60947-2
Adjustable overload releases I r
0.8 1 x I n (ex-works 0.8 x I n)
Setting on neutral pole implemen ted via the main pole setting I r of the main pole.
Adjustable short-circuit releases I i
6 10 x I n (ex-works 6 x I n)
LZM1-4-A40: 8 10 x I n (ex-works 8 x I n)
Fixed short-circuit release I i
350 A at I n = 20 32 A
1280 A at I n = 160 A (8 x I n)
LZM..1-4-A
With 100 % overload and short-circuit protection in 4th pole
Std. pack 1 off

Circuit-breakers LZM September 2011

11

1.3
1 Terminal screws

standard, terminals
as accessories

Circuit-breakers LZM
Ordering

Thermomagnetic release, 4 pole LZM...2, LZM...3


Protection of systems and cables

Rated current =
rated uninterrupted
current
In = Iu
A

Setting range

Overload releases
Main pole
Ir
A

Neutral
conductor
Ir
A

Short-circuit
releases

Basic switching capacity


25 kA at 415 V 50/60 Hz
Part no.

Article no.

Ii
A

Price

see price
list

Comfort switching capacity


36 kA at 415 V 50/60 Hz
Part no.

Article no.

Price

see price
list

I
4 pole

20

1520

1520

350

25

2025

2025

350

32

2532

2532

350

40

3240

3240

320400

50

4050

4050

300500

63

5063

5063

380630

80

6380

6380

480800

100

80100

80100

6001000

125

100125

100125

7501250

160

125160

125160

9601600

160

125160

80100

9601600

200

160200

160200

12002000

200

160200

100125

12002000

250

200250

200250

15002500

250

200250

125160

15002500

320

250320

250320

19203200

320

250320

160200

19203200

400

320400

320400

24004000

400

320400

200250

24004000

500

400500

400500

30005000

500

400500

250320

30005000

Notes

12

Notes for terminals D 25

Circuit-breakers LZM September 2011

LZMB2-4-A160
109564
LZMB2-4-A160/100
109565
LZMB2-4-A200
109566
LZMB2-4-A200/125
109567
LZMB2-4-A250
109568
LZMB2-4-A250/160
109569

LZMC2-4-A160
109570
LZMC2-4-A160/100
109571
LZMC2-4-A200
109572
LZMC2-4-A200/125
109573
LZMC2-4-A250
109574
LZMC2-4-A250/160
109575
LZMC3-4-A320
109621
LZMC3-4-A320/200
109622
LZMC3-4-A400
109623
LZMC3-4-A400/250
109624
LZMC3-4-A500
109625
LZMC3-4-A500/320
109626

Circuit-breakers LZM
Ordering

1.3
1

Normal switching capacity 50 kA


at 415 V 50/60 Hz
Part no.

Article no.

LZMN2-4-A160
109576
LZMN2-4-A160/100
109577
LZMN2-4-A200
109578
LZMN2-4-A200/125
109579
LZMN2-4-A250
109580
LZMN2-4-A250/160
109581
LZMN3-4-A320
109627
LZMN3-4-A320/200
109628
LZMN3-4-A400
109629
LZMN3-4-A400/250
109630
LZMN3-4-A500
109631
LZMN3-4-A500/320
109632

Price

see price list

Strong switching capacity 70 kA


at 415 V 50/60Hz
Part no.

Article no.

LZMS2-4-A20
109582
LZMS2-4-A25
109583
LZMS2-4-A32
109584
LZMS2-4-A40
109585
LZMS2-4-A50
109586
LZMS2-4-A63
109587
LZMS2-4-A80
109588
LZMS2-4-A100
109589
LZMS2-4-A125
109590
LZMS2-4-A160
109591
LZMS2-4-A160/100
109592
LZMS2-4-A200
109593
LZMS2-4-A200/125
109594
LZMS2-4-A250
109595
LZMS2-4-A250/160
109596
LZMS3-4-A320
109633
LZMS3-4-A320/200
109634
LZMS3-4-A400
109635
LZMS3-4-A400/250
109636
LZMS3-4-A500
109637
LZMS3-4-A500/320
109638

Notes

Price

see price list

IEC/EN 60947-2
Adjustable overload releases I r
0.8 1 x I n (ex-works 0.8 x I n)
Setting on neutral pole implemented via the main pole setting I r of the main pole.
Adjustable short-circuit releases I i
6 10 x I n (ex-works 6 x I n)
Fixed short-circuit release I i
350 A at I n = 20 32 A
LZM..2/3-4-A
With 100 % overload and short- circuit protecti on in 4th pole
LZM..2/3-4-A/60
With 60 % overload and short-circuit protection in 4th pole
Std. pack 1 off

Circuit-breakers LZM September 2011

13

1.3
1 Terminal screws

standard, terminals
as accessories

Circuit-breakers LZM
Ordering

Circuit-breakers, electronic releases, 4 pole LZM...3, LZM...4


Protection of systems and cables

Rated current =
rated uninterrupted
current
In = Iu
A

Setting range

Overload releases
Main pole
I

r
A

Neutral
conductor
Ir
A

Short-circuit
releases

Normal switching capacity 50 kA


at 415 V 50/60 Hz
Part no.

Article no.

Ii
A

Price

see price list

I
4 pole

14

400

200400

200400

8004400

400

200400

125250

8004400

630

315630

315630

12605040

630

315630

200400

12605040

800

400800

400800

16009600

800

400800

250500

16009600

1000

5001000

5001000

200012000

1000

5001000

315630

200012000

1250

6301250

6301250

250015000

1250

6301250

400800

250015000

1600

8001600

8001600

320019200

1600

8001600

5001000

320019200

Notes

Notes for terminals D 29

Circuit-breakers LZM September 2011

LZMN3-4-AE400
109643
LZMN3-4-AE400/250
109644
LZMN3-4-AE630
109645
LZMN3-4-AE630/400
109646
LZMN4-4-AE800
110968
LZMN4-4-AE800/500
110969
LZMN4-4-AE1000
110970
LZMN4-4-AE1000/630
110971
LZMN4-4-AE1250
110972
LZMN4-4-AE1250/800
110973
LZMN4-4-AE1600
110974
LZMN4-4-AE1600/1000
110975

Circuit-breakers LZM
Ordering

1.3
1

Strong switching capacity 70 kA


at 415 V 50/60Hz
Part no.

Article no.

Notes

Price

see price list

LZMS3-4-AE400
109647
LZMS3-4-AE400/250
109648
LZMS3-4-AE630
109649
LZMS3-4-AE630/400
109650
LZMS4-4-AE800
110976
LZMS4-4-AE800/500
110977
LZMS4-4-AE1000
110978
LZMS4-4-AE1000/630
110979
LZMS4-4-AE1250
110980
LZMS4-4-AE1250/800
110981
LZMS4-4-AE1600
110982
LZMS4-4-AE1600/1000
110983

IEC/EN 60947-2
Adjustable overload releases I r
0.5 1 x I n (ex-works 0.8 x I n)
Setting on neutral pole implemen ted via the main pole setting I r of the
main pole.
R.m.s. value measurement and thermal memory
Adjustable short-circuit releases I i
LZM...3-4-AE400: 2 11 x I n (ex-works 6 x I n)
LZM...3-4-AE630: 2 8 x I n (ex-works 6 x I n)
LZM...4-4-AE...: 2 12 x I n (ex-works 6 x I n)
LZM...-4-AE...
With 100 % overload and short-ci rcuit protection in 4th pole
LZM...-4-AE.../...
With 60 % overload and short-circuit protection in 4th pole

Circuit-breakers LZM September 2011

15

1.4

Circuit-breakers LZM
Engineering

1 Sizes 1, 2: tripping characteristics LZM1, LZM2


System and line protection with LZM1

Motor protection with LZM1


2.5 h 8000
6000
4000

LZM1(-4)-A...

Tripping time [s]

Tripping time [s]

2.5 h 8000
6000
4000
2000

1000
800
(10 min) 600
400

2000

1000
800
(10 min) 600
400

200

200

(1 min)

Tolerancetr [s]

100
80
(1 min) 60
40
20
10
8
6
4

100
80
60
40
20
10
8
6
4

2
Setting range

1
0.8
0.6
0.4
Ii = 6

0.2

10x In

0.02

0.02

0.01
0.008
0.006
0.004

0.01
0.008
0.006
0.004

0.002

0.002
2

5 6 7 8 9 10

15

Ii = 8

0.2
0.1
0.08
0.06
0.04

Setting range

1
0.8
0.6
0.4

0.1
0.08
0.06
0.04

0.001

LZM1-S...

20

30

0.001

40 50 60 70 80 100

5 6 7 8 9 10

14x In

15

20

30

40 50 60 70 80 100

x Ir

System and line protection with LZM2

Motor protection with LZM2

2.5 h 8000
6000
4000

2.5 h 8000
6000
4000

LZM2(-4)-A...

Tripping time [s]

Tripping time [s]

x Ir

2000

2000

1000
800
(10 min) 600
400

1000
800
(10 min) 600
400

200
100
80
(1 min) 60
40

Tolerancetr [s]

200
100
80
(1 min) 60
40
20
10
8
6
4

20
10
8
6
4
2

2
Setting range

1
0.8
0.6
0.4
Ii = 6

0.2

10x In

0.02

0.02

0.01
0.008
0.006
0.004

0.01
0.008
0.006
0.004

0.002

0.002
2

5 6 7 8 9 10

15

20

30

40 50 60 70 80 100
x Ir

16

Ii = 8

0.2
0.1
0.08
0.06
0.04

Setting range

1
0.8
0.6
0.4

0.1
0.08
0.06
0.04

0.001

LZM2-S...

Circuit-breakers LZM September 2011

0.001

5 6 7 8 9 10

14x In

15

20

30

40 50 60 70 80 100
x Ir

1.4

Circuit-breakers LZM
Engineering

Sizes 2, 3: tripping characteristics LZM2, LZM3

Systems, cable, selectivity and generator protection with LZM2

Tripping time [s]

2.5 h 8000
6000
4000

LZM2(-4)-VE...
Characteristics for I r = 1,0 x I n

2000

1000
800
(10 m in) 600
400
200

(1 m in)

100
80
60
40

10
8
6
4

t r [s]
20
17
14
10
8
6
4

20

t sd [ms]
1000
750
500

1
0.8
0.6
0.4

300
200

0.2

100
60

0.1
0.08
0.06
0.04

20
I sd = 2

5 6 7 8 9 10 x I r

0.02

I i = 12 x I n

0.01
0.008
0.006
0.004
0.002
0.001

5 6 7 8 9 10

15

20

30

40 50 60 70 80 100
x Ir

Systems, cable, selectivity and genera tor protection with LZM3

Tripping time [s]

2.5 h 8000
6000
4000

LZM3(-4)-AE...
Characteristics for I r = 1,0 x I n

2000

2.5 h 8000
6000
4000

Tripping time [s]

System and line protection with LZM3

LZM3(-4)-VE...
Characteristics for I r = 1,0 x I n

2000

1000
800
(10 m in) 600
400

1000
800
(10 m in) 600
400
200

200

100
80
(1 m in) 60
40

100
80
(1 m in) 60
40

20

20

10
8
6
4

10
8
6
4

t r [s]
20
17
14
10
8
6
4

1
0.8
0.6
0.4

1
0.8
0.6
0.4

0.2
0.1
0.08
0.06
0.04

Ii =

2 2.5 3 3.5 4

5 6 7 8

Ii =

5 6 7 8 9 11 x I n

x In

630 A

0.2

250 A, 400 A

I sd = 1.5

2 .5 3 3 .5 4

0.1
0.08
0.06
0.04

6 7

0
5 6 7 8 9 10 x I r

0.02

I sd =

0.01
0.008
0.006
0.004

0.01
0.008
0.006
0.004

Ii =

2 2 .5 3 3 .5 4

5 6 7 8

0.002

Ii =

0.002

5 6 7 8 9 10

0.001
1

5 6 7 8 9 10

15

20

30

40 50 60 70 80 100

without I 2 t = constant funct ion


630 A

20

0.02

0.001

t sd [ms]
1000
750
500
300
200
x Ir
100
60

x In

6 7 8 9 11 x I n

15

250 A, 400 A

630 A
250 A, 400 A

20

30

40 50 60 70 80 100
x Ir

x Ir

Circuit-breakers LZM September 2011

17

1.4

Circuit-breakers LZM
Engineering

1 Sizes 3, 4: tripping characteristics LZM3, LZM4


Systems, cable, selectivity and generator protection with LZM3
Tripping time [s]

2.5 h 8000
6000
4000

LZM3(-4)-VE...
Characteristics for I r = 1,0 x I n

2000

1000
800
(10 m in) 600
400
200
100
80
(1 m in) 60
40

10
8
6
4

t r [s]
20
17
14
10
8
6
4

20

1
0.8
0.6
0.4
0.2

s]

t sd

0.1
0.08
0.06
0.04

I sd = 1 .5

I sd =

Ii =

I 2 t = constant

00

..1

....

..
20

[m

2 . 5 3 3 . 54

5 6 7

x Ir

630 A

5 6 7 8 910

x Ir

250 A, 400 A

2 2.5 3 3.5 4

5 6 7 8

x In

630 A

5 6 7 8 9 11 x I n 250 A, 400 A

5 6 7 8 9 10

0.02
0.01
0.008
0.006
0.004

Ii =

0.002
0.001

15

20

30

40 50 60 70 80 100
x Ir

18

Circuit-breakers LZM September 2011

Circuit-breakers LZM
Engineering

1.4

Frame size 1: let-through characteristics LZM1

Let-through current D

60

60

2x

2x

Ic

Ic

100
80
c

100
80

D 200 LZMC1-A20...160
[kA]

D 200 LZMB1(-4)-A(S)15...160
[kA]

40

40

20

20
415 V+440 V

10
8

415 V
440 V
10
8

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0 1 0 0 1 5 0
I cc rms [kA]

525 V
690 V

D 200 LZMS1(-4)-A20...160
[kA]

D 200 LZMN1(-4)-A(S)15...160
[kA]

100
80

60

60

40

40

20
415 V

10
8

525 V
690 V

415 V
10
8

525 V

690 V

4
3

4
3

2x

2x

Ic

Ic

100
80

20

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0 1 0 0 1 5 0
I cc rms [kA]

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0 1 0 0 1 5 0
I cc rms [kA]

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

Circuit-breakers LZM September 2011

19

1.4

Circuit-breakers LZM
Engineering

1 Frame size 2: let-through characteristics LZM2


D
D 200
[kA]
100
80

60

60

2x

2x

Ic

100
80

LZMC2-A160...300

D 200 LZMB2(-4)-A(S)1,6...300
[kA]

Ic

Let-through current

40

40
440 V
NZMB2-A160...250

20

20

10
8

10
8

6
415 V+440 V
NZMB2(-4-A)-M20...250
NZMB2...-(C)NA

4
3

D 200
[kA]

440 V

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0 1 0 0 1 5 0
I cc rms [kA]

525 V

690 V

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0 1 0 0 1 5 0
I cc rms [kA]

D 200 LZMS2(-4)-A(M,VE)15...250
[kA]

LZMN2(-4)-A(S,VE)1,6...250

100
80

60

60

40

40

415 V
525 V
690 V

10
8

20

10
8
6

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

Circuit-breakers LZM September 2011

415 V
525 V

2x

2x

20

20

Ic

Ic

100
80

690 V

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

Circuit-breakers LZM
Engineering

1.4

Sizes 1, 3: let-through characteristics LZM1, LZM3


Let-through current

D
D 200
[kA]

D 200 LZMN3(-4)-AE(VE)400...630
[kA]
100
80

100
80

60

60

40

40

525 V

690 V

415 V

Ic

2x

Ic

690 V

2x

20

20
525 V
415 V

10
8

10
8

LZMS3(-4)-AE(VE)400...630

1
1

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

Let-through energy I 2t
10 7
Zy
8 LZMB1(-4)-A(S)15...160
[A 2 s] 6

10 7
Zy
8 LZMC1-A20...160
[A 2 s] 6

525 V
440 V

10 6

10 6
8
6

440 V

8
6

415 V

690 V

415 V
2

10 5
8
6

10 5
8
6

2
10 4

10 4
1

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

7
Zy 10
8 LZMN1(-4)-A(S)15...160
[A 2 s] 6

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

10 7
Zy
8 LZMS1(-4)-A20...160
[A 2 s] 6

2
10 6
8
6

415 V
525 V

690 V

2
10 6
8
6

525 V
690 V

10 5
8
6

10 5
8
6

10 4

415 V

10 4
1

a 1 half-cycle

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

a 1 half-cycle
Circuit-breakers LZM September 2011

21

1.4

Circuit-breakers LZM
Engineering

1 Sizes 2, 3: let-through characteristics LZM2, LZM3


Let-through energy I 2t
7
Zy 10
8 LZMC2-A160...250
[A 2 s] 6

7
Zy 10
8 LZMB2(-4)-A(S)15...250
[A 2 s] 6

440 V
LZMB2-A160...250

10 6
8
6

10 6
8
6

440 V
690 V

415 V+440 V
LZMB2(-4-A)S20...250

10 5
8
6

10 5
8
6

10 4

525 V

10 4
1

7
Zy 10
8
[A 2 s] 6

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

7
Zy 10
8
[A 2 s] 6

LZMN2(-4)-A(S)15...250

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

LZMS2(-4)-A(S,VE)15...250

2
10 6
8
6

10 6
8
6
4

415 V
525 V

690 V

415 V
525 V

10 5
8
6

10 5
8
6

690 V

10 4

10 4
1

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 0100 150
I cc rms [kA]

a 1 half-cycle
7
Zy 10
8
[A 2 s] 6

7
Zy 10
8
[A 2 s]
6

LZMN3(-4)-AE(VE)400...630

LZMS3(-4)-AE(VE)400...630

690 V

10 6
8
6

525 V
415 V

690 V

10 6
8
6

525 V

4
415 V

10 5
8
6

10 5
8
6

10 4

10 4
1

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 01 0 0 1 5 0

I cc rms [kA]

a 1 half-cycle
22

3 4 5 6 8 10 15 20 30 4 0 5 0 6 0 8 01 0 0 1 5 0
I cc rms [kA]

a 1 half-cycle
Circuit-breakers LZM September 2011

Circuit-breakers LZM
Dimensions

84.5

Size 1: basic units LZM1

68
NZM...1-...-(C)NA
a

30
f 60

10.2

9.5

21
57

41.5

16

145

63

90

45

126

112

R1

04

64

Circuit-breaker
3 pole
LZMB1
LZMC1
LZMN1
LZMS1

1.5

162
M4 x 50/10

SW4

30

44.6

90

a Blow out area, minimum clearance to other parts 60 mm


84.5
68

21

f 60

60

89

4
R10

63

45

145

126

112

64

41.5

16

9.5

Circuit-breaker
4 pole
LZMB1-4
LZMC1-4
LZMN1-4
LZMH1-4

M4 x 50

SW4

30

44.6

120

a Blow out area, minimum clearance to other parts 60 mm


21
4

16

Covers
NZM1(-4)-XKSA
Screw connection
NZM1(-4)-XKS
IP2X protection against
contact with a finger
for shroud
NZM1(-4)-XIPA
Screw connection

IP2X
M6 x 14

26

80

158

296

64

34

SW 4

90 a

59

120 b

a 3 pole
b 4 pole

Circuit-breakers LZM September 2011

23

1.5

Circuit-breakers LZM
Dimensions

1 Size 2: accessories NZM2-XK, NZM2-XIP, NZM2-XST


Box terminal
(+)NZM2(-4)-...-XKC(O)(U)
IP2X protection against contact with a finger
NZM2(-4)-XIPK

Tunnel terminal
NZM2(-4)-XKA

30

25

65
25
19

F 22.1

80

55

80

111

20

SW 5

37

SW 8
M10

SW 5

105
140

105 a
140 b

a 3 pole
b 4 pole

Control circuit terminal


NZM2-XSTS
NZM-XSTK

100

Covers
NZM2(-4)-XKSA
Cable lug
NZM2-XKS185
IP2X protection against contact with a finger for shroud
NZM2(-4)-XIPA

SW 5

337

105

80

M8 x 22

175

105 a

81

140 b

105 a

87

140 b

a 3 pole
b 4 pole

24

Circuit-breakers LZM September 2011

M8 x 22

Circuit-breakers LZM
Dimensions

1.5

Size 3: Basic units LZM3

1
166
120.5
NZM...3-...-4(C)NA

11

31

5
M10 x 30
28 29.5

20.5

275

45

f 60

234

Circuit-breaker
3 pole
LZMC3
LZMN3
b
LZMS3

315.5
117

216

95

123.5

R 205

135

a
5

M5 x 75

60

SW5
45

69.7

140

a Blow-out space, minimum distance to other parts 60 mm


b Minimum distance to adjacent parts 5 mm

166

31
M10 x 30

2 8 2 9 .5

f 60

90

275

20.5

120.5

234

Circuit-breaker
4 pole
LZMC3-4
LZMN3-4
b
LZMS3-4

R 205

123.4

135

117

216

95

SW5

60

45

a
185

69.7

M5 x 75

a Blow-out space, minimum distance to other parts 60 mm


b Minimum distance to adjacent parts 5 mm

Circuit-breakers LZM September 2011

25

Eatons Electrical Sector


is a global leader in power
distribution, power quality,
control and automation, and
monitoring products. When
combined with Eatons fullscale engineering services,
these products provide
customer-driven PowerChain
ManagementT solutions to
serve the power system
needs of the data center,
industrial, institutional, public
sector, utility, commercial,
residential, IT, mission critical,
alternative energy and OEM
markets worldwide.

PowerChain Management
solutions help enterprises
achieve sustainable and
competitive advantages through
proactive management of the
power system as a strategic,
integrated asset throughout its
life cycle, resulting in enhanced
safety, greater reliability and
energy efficiency. For more
information, visit
www.eaton.com/electrical.

Eaton Corporation
Asia Pacific Headquarter
No.3, Lane 280, Linhong Road,
Changning District,
Shanghai 200335
Tel86-21-52000099
Fax86-21-52000200
2011 Eaton Corporation
All Rights Reserved
Printed in China
LZM-CHN(10-2011)

All trademarks are property of their


respective owners.

Potrebbero piacerti anche