Sei sulla pagina 1di 1

PROVISION OF TECHNICAL FACILITIES

AT SITE - B

NOTES:
DO NOT SCALE THE DRG. ONLY WRITTEN
DIMENSIONS TO BE FOLLOWED.
DRG. TO BE READ IN CONJUNCTION WITH
CORRESPONDING DETAILED DRG.
ANY DESCREPANCY IN THE DRG.SHOULD BE
BROUGHT TO THE NOTICE OF THE
CONSULTANT FOR CLARIFICATION BEFORE
EXECUTION.

NO. DATE

REVISION

NOTES:

1) UNLESS NOTED OTHERWISE WELDING SHALL BE DONE IN ACCORDANCE WITH


IS STANDARDS

2) SHOP WELDING: i. ALL SHOP WELDS SHALL BE CARRIED OUT IN A'DANCE WITH
IS:816-1969 ii. WHENEVER POSSIBLE MACHINE WELDING SHALL BE USED

3) SITE WELDING: i. ALL SITE WELDING SHALL BE CARRIED OUT BY MANUAL


METAL ARC OR TUNGSTEN INERT GAS PROCESS. ii. WHENEVER POSSIBLE ALL
WELDING SHALL BE DONE IN THE FLAT OR HORIZONTAL/VERTICAL POSITIONS.

4) PREPARATION OF JOINT FACES: THIS SHALL BE DONE BY SHEARING ,


CHIPPING, GRINDING, MACHINING, THERMAL GOUGING THE PREPARATION OF
FUSION FACES, ANGLE OF BEVEL, ROOT RADIUS SHALL BE SUCH THAT THE
LIMITS OF ACCURACY BY THE APPROPRIATE APPLICATION STANDARD CAN BE
ACHIVED.

5) THE EDGES AND SURFACES TO BE JOINED BY FILLET WELDS SHALL BE IN


CLOSE CONTACT AS POSSIBLE, BUT IN NO CASE SHALL THE GAP EXCEED 3mm.

6) FILLET WELDS TERMINATING AT THE ENDS OR SIDES OF PARTS SHOULD BE


RETURNED, CONTINEOUS AROUND THE CORNERS FOR A DISTANCE OF NOT
LESS THAN TWICE THE LEG LENGTH OF THE WELD

8) TACK WELD TACK WELDS SHALL BE NOT LESS THAN THE THROAT
THICKNESS OF THICKER PART OR 50mm WHICHEVER IS THE SMALLER.

9) REFERENCE CODES:
CODE OF PRACTICE FOR GENERAL CONSTRUCTION STEEL

1. IS:800-2007 STRUCTURAL STEEL (STANDARD QUALITY/FUSION

2. IS:2062-1992 WELDING QUALITY) / WEILDABLE STRUCTURAL STEEL


SPECIFICATION OF COVERED ELECTRODES FOR METAL

3. IS:814-1991 ARC WELDING FOR STRUCTURAL STEEL. CLASSIFICATION AND


CODING OF COVERED ELECTRODES

4. IS:816-1996 FOR METAL ARC WELDING OF MILD STEEL AND LOW ALLOY
HIGH-TENSILE STEEL. CODE OF PROCEDURE FOR INSPECTION OF WELDS.

5. IS:822-1970 SPECIFICATIONS FOR ROLLING AND CUTTING TOLERANCE

6. IS:1852-1985 FOR HOT ROLLED STEEL PRODUCTS. SPECIFICATIOS FOR


HEXAGON BOLTS FOR STEEL STR.

7. IS:6639-1970 SPECIFICATIONS FOR FOUNDATIONS BOLTS

CCE ( R & D) WEST

370

R02

505,BEZZOLA COMPLEX, SION TROMBAY


ROAD, CHEMBUR, MUMBAI - 400071.
PHONE : 40885587 FAX : 2528 53 09

370-02PEB-T2

TENDER DRAWING
SECTIONS & DETAILS
PEB STRUCTURE
OPS.TECHNICAL FACILITY

8. IS:5624-1993 SPECIFICATION FOR COUNTERSUNK HEAD SCREWS WITH 9.


IS:6791-1994

CLIENT

PROVISION OF TECHNICAL FACILITIES AT SITE - B

7) FILLET WELDS APPLIED AT THE EDGE OF A PART: WHERE THE SPECIFIED LEG
LENGTH OF A FILLET WELD AT THE EDGE OF A PLATE OR SECTION IS SUCH THAT
THE PARENT METAL DOES NOT PROJECT BEYOND THE WELD. METAL OF THE
OUTER CORNER OR CORNERS, WHICH REDUCED THE THROAT THICKNESS
SHALL NOT BE ALLOWED.