Sei sulla pagina 1di 2

LUMARK

D ES C R IPTION

Roadway Cobrahead fixtures feature durable die-cast aluminum


construction and a computer-designed optical system for sturdiness and
optimum photometric control.

Type

Catalog #
Project

Date

Comments
Prepared by

SPE C IFIC A TION FEA T U R E S

C on s t r u c t i o n

El e c tri c a l

Mo u n ting

HOUSING: Die-cast aluminum


housing and latch. DOOR: Die-cast
aluminum door frame with integral
hinges for hands free installation,
relamping and maintenance. Door
frame has two-position latch to
ensure door stays fastened under
extreme conditions.

SOCKET: Adjustable mogul-base


porcelain socket. BALLAST: Hard
mounted ballast with encapsulated
starter and plastic terminal block
for protection from environmental
abuse.

Two-bolt/one clamp slipfitter for


1-1/4 or 2 mounting arms.
Fin ish

Standard grey polyester powder


coat finish.

O pti c a l

REFLECTOR: The optical system is


a hydroformed anodized aluminum
reflector with a Dacron polyester
filter. LENS: Removable prismatic
refractor for use with Metal
Halide, Pulse Start Metal Halide
and High Pressure Sodium lamp
sources. Full cutoff lens is Dark Sky
Compliant.

RY
ROADWAY
COBRAHEAD
50-400W
Metal Halide
High Pressure Sodium
Pulse Start Metal Halide

SITE/ROADWAY LIGHT

D IMENS IONS

S W I N G - D OWN BA L L A ST MOD UL E

TECHNICAL DATA
U.L. Wet Location Listed
3G Vibration Rated
EISA Compliant G

ENERGY DATA
High Reactance Ballast Watts
100W HP NPF (130 Watts)
100W MP NPF (128 Watts)
150W HP HPF (190 Watts)
150W MP HPF (185 Watts)

13-1/4" [337mm]

VO L T A GE CH A RT
MT=Multi-Tap

120/208/240/277V wired 277V

TT=Triple-Tap

120/277/347V wired 347V

EPA
Effected Projected Area:
.87 Square Feet

SHIPPING DATA
Approximate Net Weight:
49 lbs. (22 kgs.)

ER

TEM
S

YS

11-1/4"
[286mm]

CWA Ballast Input Watts


200W MP HPF (227 Watts) G
250W MP HPF (283 Watts) G
250W HP HPF (300 Watts)
320W MP HPF (365 Watts) G
350W MP HPF (400 Watts) G
400W MP HPF (452 Watts) G
400W HP HPF (465 Watts)

28-1/4" [718mm]

TIFIE

ADH090196
2015-02-25 09:17:43

RY ROA DW A Y C O B R A H EA D

PH OTOM ETR IC S
4

A B C

E
B
A

4
5

Footcandle Table
Select mounting height and read across for
footcandle values of each isofootcandle line.
Distance in units of mounting height.
Mounting Footcandle Values for
Height
Isofootcandle Lines
A
B
C
D
HPRY-GL-2-250-MT-LL / HPRY-GL-3-400-MT-LL
25'
3.80
1.90
0.95
0.38
30'
2.80
1.40
0.70
0.28
35'
2.00
1.00
0.50
0.20
40'
1.54
0.77
0.39
0.15

E
0.19
0.14
0.10
0.08

4
5

HPRY-GL-3-400-MT-LL
400Watt HP
50,000Lumen Clear Lamp
Type III-Medium Semi-Cutoff

HPRY-GL-2-250-MT-LL
250Watt HP
27,500Lumen Clear Lamp
Type II-Medium Semi-Cutoff

ORDER ING INFOR M A TION


Sample Number: MPRY-AL-2-50-120V
Lamp Type

Series

Lens Type

MP=Pulse Start Metal Halide


MH=Metal Halide 1
HP=High Pressure Sodium

RY=Roadway Cobrahead

AL=Acrylic Refractor
GL=Glass Refractor
PL=Polycarbonate Refractor 2
FL=Flat Glass Lens 3
2

Distribution

Lamp Wattage 4

Voltage 5

2=Type II
3=Type III

Pulse Start Metal Halide


50=50W
70=70W
100=100W
150=150W
250=250W
320=320W
350=350W
400=400W

120V=120V
208V=208V
240V=240V
277V=277V
347V=347V 6
480V=480V
MT=Multi-Tap, wired 277V 7
TT=Triple-Tap, wired 347V 6, 7

Metal Halide
175=175W 1
250=250W 1
400=400W 1
High Pressure Sodium
50=50W
70=70W
100=100W
150=150W
250=250W
400=400W
Options (Add as Suffix)

Accessories (Order Separately)

F1=Single Fuse (120, 277 or 347V Only)


F2=Double Fuse (208, 240 or 480V Only)
LL=Lamp Included 8
CEC=California Title 20 Compliant Ballast (Applies to 250-320W and 400W MP Only)
PER=NEMA Twistlock Photocontrol Receptacle
PC=Button Type Photocontrol - 120V
H=Plug-In Starter 9
K=Leveling Indicator
T=Swing-Down Ballast

OA/RA1016=NEMA Type Photocontrol - 105-285V


OA/RA1201=NEMA Type Photocontrol - 347V
OA/RA1027=NEMA Type Photocontrol - 480V
OA1028=Field Installed NEMA Twistlock Photocontrol Receptacle (Order Photocontrol Separately)
OA/RA1013=Photocontrol Shorting Cap

Notes:
1. 175W, 250W and 400W metal halide available in non-U.S. markets only.
2. Arcylic refractor for 175W maximum. Polycarbonate refractor for 250W maximum.
3. 400W metal halide requires reduced envelope lamp (ED28) for flat glass.
4. 100W and below metal halide are medium-base. All other lamps are mogul-base. Lamp not included.
5. Products also available in non-US voltages and 50Hz for international markets.
6. 88% efficient EISA Compliant fixtures not available in 347V or Triple-tap voltages.
7. Multi-tap ballast is 102/208/240/277V wired 277V. Triple-tap ballast is 120/277/347V wired 347V.
8. Lamp is shipped separate from luminaire. Lamp is Cooper Lighting designated product based on luminaire requirements. Specified lamps must be ordered as a separate line item.
9. High pressure sodium only.

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

Eatons Cooper Lighting Business


1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com

Specifications and
dimensions subject to
change without notice.

ADH090196