Sei sulla pagina 1di 4

CERTIFICATIONS

ACCESSORIES

ISO 9001
Quality Management System

RVS
(remote venting system) for IP rated applications
which require remote gassing

ISO 14001
Environmental Management System

SLA

Rack for battery installation


(standard and seismic)

OHSAS 18001
Workplace Safety & Health

Cabinets for battery installation


(including electrical protections and disconnection)
Battery monitoring systems

DISCHARGE CURVES at different current / final voltage (at 20C)


2.2

Battery Voltage (V/cell)

2.1
2.0
1.9
1.8

0.05 C

1.7

0.10 C
0.26 C

1.6

2C

1.22 C

0.68 C

1.5
1

10

100

10.000

1.000

Discharge time (min)


The above discharge curves are typical. For more detailed information please see the specific product sheets.

STORAGE

Battery Voltage and Charge Time for Standby Use (at 20C)

Capacity loss during storage at various temperatures

100
80

14

0.10 C20
60
40

0.05 C20

13
12
11

10

0
0

10

15

20

5C

60

Refreshing charge of
2.4 Vpc may be
insufficient to recover
the battery capacity.
It is important to
avoid this area

Charging Current (A)

Discharge 100%
50%

80

Refreshing charge at
2.4 Vpc for 24 hours
(at 20-25C) must be
applied as soon as
possible.

Recharged Capacity (%)

20

100

The battery can be


used without
refreshing charge

Battery Voltage (V)

40

25

Charging time (h)

10

12

14

16

18

20

Storage Time (months)

FIAMM S.p.A.
V i a l e E u r o p a , 7 5 - 3 6 0 7 5 M o n t e c c h i o M a g g i o r e ( V I ) - I TA LY
TEL +39 0444 709311

20C

30C

40C

Remaining Capacity (%)

120

15

Charging Voltage (V)

Recharged Capacity (%)

140

Charging Current (A)

TYPICAL CHARGE CURVES

SLA Battery Range

Fax +39 0444 694178

e-mail: info.standby@fiamm.com
w w w. f i a m m . c o m
fiamm.batteries
fiammbatteries
youtube.com/user/FIAMMvideo
FIAMM.COM

I A M M S L A R A N G E O F VA LV E R E G U L AT E D B AT T E R I E S

TECHNOLOGY
FIAMM

H A S B E E N D E S I G N E D F O R A P P L I C AT I O N S D E M A N D I N G

Internal Strap

T H E H I G H E S T L E V E L O F R E L I A B I L I T Y A N D S E C U R I T Y.

Terminal Pillar
THE

MOST

UNSURPASSED

CRITICAL

PROVEN

APPLICATIONS,

RELIABILITY,

USES

VRLA

RECOMBINATION

TECHNOLOGY
EFFICIENCY,

IS

WITH

99%

Separators

OF

RANGE

ELECTROLYTE
IS

DURING

NON-HAZARDOUS

ITS
FOR

FLOAT-

LIFE.

99%

GLASS
THE

INTERNAL

R E C O M B I N AT I O N

GRANTS

AND

AND

BLOCS

NO

AIR/SEA/RAIL/ROAD

MAINTENANCE

Negative Flat Plate

A SELF-DISCHARGE RATE LESS THAN 2% PER MONTH,

WHOLE

LIFE.

DISCHARGE

The image is for illustrative purposes only.

FREE

REQUIRES

TOPPING

E L E C T R O LY T E

TRANSPORTATION AND IS 100% RECYCLABLE. SLA HAS

ARE

NON-SPILLABLE

THEREFORE

SLA

GUARANTEEING LONG SHELF-LIFE.

T E C H N O L O G Y.

E F F I C I E N C Y.

MAINTENANCE FREE THEREFORE REQUIRES NO TOPPING


UP

M AT )

GAS

INTERNAL

NON-SPILLABLE

(ABSORBED

WITH

WITH

THE HIGHEST RECOGNISED INTERNATIONAL STANDARDS.


SLA

AGM

USE

I N F I B E R G L A S S S E PA R AT O R S

OFFERING

COMPLIANT

RANGE

E L E C T R O LY T E I S A B S O R B E D

FIAMM HIGH INTEGRITY SLA RANGE HAS BEEN DESIGNED


FOR

SLA

UP

OF

DURING
LOW

ITS

SELF-

ALLOWS

MONTHS SHELF LIFE.

BATTERY
TYPE

SPECIFICATIONS
Industrial/Telecom specification high purity lead calcium tin grids designed to resist corrosion
VRLA AGM technology using low resistance high microporous fiberglass separators
Leak resistant post seal, threaded female M6/M8/M10 terminals with high conductivity and maximum torque resistance

NOMINAL
VOLTAGE
(V)

CAPACITY AT 20C
(Ah)

SHORT CIRCUIT
CURRENT
(A)

INTERNAL
RESISTANCE
(mOhm)

10 HRS TO 1.8 VPC

IEC 60896 21-22

IEC 60896 21-22

DIMENSIONS (mm)
Length

Flame retardant ABS plastic to IEC 707 FV0 and UL94 FV0 (LOI greater than 28%)
Thick walled plastics designed for superior mechanical strength
Heat sealed box to lid weld for superior integrity
Installation in any orientation (excluding permanently inverted)

Height

12 SLA 26

12

24

884

14

166

175

125

9.5

12 SLA 50 L

12

50

1550

8.3

261

174

219

21

12 SLA 70 L

12

70

2000

6.5

261

174

219

25

12 SLA 80 L

12

80

2144

6.0

302

174

219

29

12 SLA 110 L

12

110

3000

4.2

379

174

219

37

6 SLA 125

125

4300

1.40

268

172

230

24

4 SLA 150

150

5000

0.70

271

173

202

19

6 SLA 160

160

3050

1.96

298

202

226

32

6 SLA 180*

180

3400

1.75

388

173

236

35

6 SLA 200

200

3700

1.58

250

125

366

36

4 SLA 200

200

3800

1.00

250

202

226

26

2 SLA 250

250

5900

0.35

271

173

202

17

2 SLA 300

300

6300

0.32

271

173

202

19

2 SLA 330

330

7500

0.27

208

195

230

22

2 SLA 405/4*

405

7600

0.26

250

202

226

27

2 SLA 500*

500

9700

0.21

388

173

236

34

2 SLA 580*

580

10800

0.19

388

173

236

37

2 SLA 800**

820

9700

0.206

254

210

495

64

2 SLA 1000**

1025

12000

0.165

254

210

495

74

2 SLA 1500**

1500

16000

0.125

275

210

660

105

2 SLA 2000**

2000

20000

0.102

368

218

660

137

* The front view is the short side


** This cell must be installed horizontally

One-way safety relief valves allow gas to escape and prevent the ingress of oxygen.
Flame arrestors prevent sparks or flames entering the battery

Width

WEIGHT
(kg)

ELECTRICAL CHARACTERISTICS

STANDARDS

Float Voltage: 2.27 V/cell at 20C


Boost Voltage: 2.35 V/cell
Float Voltage Compensation with Temperature: -2.5 mV/cell/C
Self-Discharge at 20C: <2%/month

IEC 60896 Part 21 - VRLA methods of testing


IEC 60896 Part 22 - VRLA requirements
BS 6290 Part 4 - specifications for VRLA classification
Telcordia GR-4228 - VRLA battery string certification
BS 6334 / UL 94 V0 / IEC 707 FV0
determination of materials flammability
Bellcore TR-NWT-000766 - VRLA battery generic requirements
UL 1778 - UPS equipment
Eurobat >12 years VERY LONG LIFE

FIAMM reserves the right to change or revise without notice any information or detail given in this publication

SLA Battery Range_2016_02_22

I A M M S L A R A N G E O F VA LV E R E G U L AT E D B AT T E R I E S

TECHNOLOGY
FIAMM

H A S B E E N D E S I G N E D F O R A P P L I C AT I O N S D E M A N D I N G

Internal Strap

T H E H I G H E S T L E V E L O F R E L I A B I L I T Y A N D S E C U R I T Y.

Terminal Pillar
THE

MOST

UNSURPASSED

CRITICAL

PROVEN

APPLICATIONS,

RELIABILITY,

USES

VRLA

RECOMBINATION

TECHNOLOGY
EFFICIENCY,

IS

WITH

99%

Separators

OF

RANGE

ELECTROLYTE
IS

DURING

NON-HAZARDOUS

ITS
FOR

FLOAT-

LIFE.

99%

GLASS
THE

INTERNAL

R E C O M B I N AT I O N

GRANTS

AND

AND

BLOCS

NO

AIR/SEA/RAIL/ROAD

MAINTENANCE

Negative Flat Plate

A SELF-DISCHARGE RATE LESS THAN 2% PER MONTH,

WHOLE

LIFE.

DISCHARGE

The image is for illustrative purposes only.

FREE

REQUIRES

TOPPING

E L E C T R O LY T E

TRANSPORTATION AND IS 100% RECYCLABLE. SLA HAS

ARE

NON-SPILLABLE

THEREFORE

SLA

GUARANTEEING LONG SHELF-LIFE.

T E C H N O L O G Y.

E F F I C I E N C Y.

MAINTENANCE FREE THEREFORE REQUIRES NO TOPPING


UP

M AT )

GAS

INTERNAL

NON-SPILLABLE

(ABSORBED

WITH

WITH

THE HIGHEST RECOGNISED INTERNATIONAL STANDARDS.


SLA

AGM

USE

I N F I B E R G L A S S S E PA R AT O R S

OFFERING

COMPLIANT

RANGE

E L E C T R O LY T E I S A B S O R B E D

FIAMM HIGH INTEGRITY SLA RANGE HAS BEEN DESIGNED


FOR

SLA

UP

OF

DURING
LOW

ITS

SELF-

ALLOWS

MONTHS SHELF LIFE.

BATTERY
TYPE

SPECIFICATIONS
Industrial/Telecom specification high purity lead calcium tin grids designed to resist corrosion
VRLA AGM technology using low resistance high microporous fiberglass separators
Leak resistant post seal, threaded female M6/M8/M10 terminals with high conductivity and maximum torque resistance

NOMINAL
VOLTAGE
(V)

CAPACITY AT 20C
(Ah)

SHORT CIRCUIT
CURRENT
(A)

INTERNAL
RESISTANCE
(mOhm)

10 HRS TO 1.8 VPC

IEC 60896 21-22

IEC 60896 21-22

DIMENSIONS (mm)
Length

Flame retardant ABS plastic to IEC 707 FV0 and UL94 FV0 (LOI greater than 28%)
Thick walled plastics designed for superior mechanical strength
Heat sealed box to lid weld for superior integrity
Installation in any orientation (excluding permanently inverted)

Height

12 SLA 26

12

24

884

14

166

175

125

9.5

12 SLA 50 L

12

50

1550

8.3

261

174

219

21

12 SLA 70 L

12

70

2000

6.5

261

174

219

25

12 SLA 80 L

12

80

2144

6.0

302

174

219

29

12 SLA 110 L

12

110

3000

4.2

379

174

219

37

6 SLA 125

125

4300

1.40

268

172

230

24

4 SLA 150

150

5000

0.70

271

173

202

19

6 SLA 160

160

3050

1.96

298

202

226

32

6 SLA 180*

180

3400

1.75

388

173

236

35

6 SLA 200

200

3700

1.58

250

125

366

36

4 SLA 200

200

3800

1.00

250

202

226

26

2 SLA 250

250

5900

0.35

271

173

202

17

2 SLA 300

300

6300

0.32

271

173

202

19

2 SLA 330

330

7500

0.27

208

195

230

22

2 SLA 405/4*

405

7600

0.26

250

202

226

27

2 SLA 500*

500

9700

0.21

388

173

236

34

2 SLA 580*

580

10800

0.19

388

173

236

37

2 SLA 800**

820

9700

0.206

254

210

495

64

2 SLA 1000**

1025

12000

0.165

254

210

495

74

2 SLA 1500**

1500

16000

0.125

275

210

660

105

2 SLA 2000**

2000

20000

0.102

368

218

660

137

* The front view is the short side


** This cell must be installed horizontally

One-way safety relief valves allow gas to escape and prevent the ingress of oxygen.
Flame arrestors prevent sparks or flames entering the battery

Width

WEIGHT
(kg)

ELECTRICAL CHARACTERISTICS

STANDARDS

Float Voltage: 2.27 V/cell at 20C


Boost Voltage: 2.35 V/cell
Float Voltage Compensation with Temperature: -2.5 mV/cell/C
Self-Discharge at 20C: <2%/month

IEC 60896 Part 21 - VRLA methods of testing


IEC 60896 Part 22 - VRLA requirements
BS 6290 Part 4 - specifications for VRLA classification
Telcordia GR-4228 - VRLA battery string certification
BS 6334 / UL 94 V0 / IEC 707 FV0
determination of materials flammability
Bellcore TR-NWT-000766 - VRLA battery generic requirements
UL 1778 - UPS equipment
Eurobat >12 years VERY LONG LIFE

FIAMM reserves the right to change or revise without notice any information or detail given in this publication

SLA Battery Range_2016_04_06

CERTIFICATIONS

ACCESSORIES

ISO 9001
Quality Management System

RVS
(remote venting system) for IP rated applications
which require remote gassing

ISO 14001
Environmental Management System

SLA

Rack for battery installation


(standard and seismic)

OHSAS 18001
Workplace Safety & Health

Cabinets for battery installation


(including electrical protections and disconnection)
Battery monitoring systems

DISCHARGE CURVES at different current / final voltage (at 20C)


2.2

Battery Voltage (V/cell)

2.1
2.0
1.9
1.8

0.05 C

1.7

0.10 C
0.26 C

1.6

2C

1.22 C

0.68 C

1.5
1

10

100

10.000

1.000

Discharge time (min)


The above discharge curves are typical. For more detailed information please see the specific product sheets.

STORAGE

Battery Voltage and Charge Time for Standby Use (at 20C)

Capacity loss during storage at various temperatures

100
80

14

0.10 C10
60
40

0.05 C10

13
12
11

10

0
0

10

15

20

5C

60

Refreshing charge of
2.4 Vpc may be
insufficient to recover
the battery capacity.
It is important to
avoid this area

Charging Current (A)

Discharge 100%
50%

80

Refreshing charge at
2.4 Vpc for 24 hours
(at 20-25C) must be
applied as soon as
possible.

Recharged Capacity (%)

20

100

The battery can be


used without
refreshing charge

Battery Voltage (V)

40

25

Charging time (h)

10

12

14

16

18

20

Storage Time (months)

FIAMM S.p.A.
V i a l e E u r o p a , 7 5 - 3 6 0 7 5 M o n t e c c h i o M a g g i o r e ( V I ) - I TA LY
TEL +39 0444 709311

20C

30C

40C

Remaining Capacity (%)

120

15

Charging Voltage (V)

Recharged Capacity (%)

140

Charging Current (A)

TYPICAL CHARGE CURVES

SLA Battery Range

Fax +39 0444 694178

e-mail: info.standby@fiamm.com
w w w. f i a m m . c o m
fiamm.batteries
fiammbatteries
youtube.com/user/FIAMMvideo
FIAMM.COM

Potrebbero piacerti anche