Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
All right reserved. No part of this document may be reproduced in any form without
prior written permission of Engineering Dynamics, Inc.
6/24/2010
EngineeringDynamics,Inc
Overview
Theold(wewillcallitAPI2000):
APIRP2A WSD21st edition2000
Publication
Andthelatest(wewillcallitAPI2007):
APIRP2A WSD21st edition2007Publication
(API2007)
6/24/2010
EngineeringDynamics,Inc
Conclusions
1.
2.
3.
6/24/2010
EngineeringDynamics,Inc
StrengthofTubularJoints
CodeContents
API2000
API2007
4 Connections
4.1 Connections of Tension and Compression
Members
4.2 Restraint and Shrinkage
4.3 Tubular Joints
6/24/2010
EngineeringDynamics,Inc
StrengthofTubularJoints
Background
Fact:
Lastmajorupdatetojointstrengthprovisions
was14th edition.Theguidanceessentially
remainedunchangedforalleditionsupto
21st.
6/24/2010
EngineeringDynamics,Inc
StrengthofTubularJoints
Background
Fact:
Muchfurtherknowledge,includingbothexperimental
dataandnumericalstudies,hasbeengainedonthe
behaviorofjointssince14th editionissued.Overthe
period1994to1996MSLengineering,underthe
auspicesofajointindustryproject,undertookan
updatetothetubularjointdatabaseandguidance.
Thisworkhadmorerecentstudies,notablybyAPI/EWI
andtheUniversityofIllinois,haveformedthebasisof
thetubularjointstrengthprovisionsofISO.
6/24/2010
EngineeringDynamics,Inc
StrengthofTubularJoints
Background
Fact:
TheISOdraftingcommitteetook,asastarting
pointfordrafting,therelevantprovisionsfrom
APIRP2ALRFD1st edition(similartoAPIRP2A
WSD20th edition)becauseISOisinLRFDformat.
Forthepurposeofthesupplementtothe21st
editionofAPIRP2A,thedraftISOprovisions,in
turn,havebeenusedasastartingbasis.
6/24/2010
EngineeringDynamics,Inc
StrengthofTubularJoints
MajorUpdate
Minimum Capacity Check Revised
API2000
API2007
InSACSprogramthefollowingequationisused:
InwhichPaiscalculatedasfollowswithFS=1.0
6/24/2010
EngineeringDynamics,Inc
StrengthofTubularJoints
MajorUpdate
SafetyFactorRecalibrated
API2000
API2007
SF=1.7CorrespondedtoanLRFD
resistancefactorof0.95.
SF=1.6CorrespondedtoanLRFD
resistancefactorof1.0
6/24/2010
EngineeringDynamics,Inc
StrengthofTubularJoints
MajorUpdate
The2/3limitsontensilestrengthrelaxed
API2000
API2007
Section4.1
Fyc theyieldstrengthofthechord
memberatthejoint(or2/3ofthe
tensilestrengthifless)
Section4.2.1
Thevalueofyieldstressforthechord,
inthecalculationofjointcapacity,
shouldbelimitedto0.8timesthe
tensilestrengthofthechord for
materialswithayieldstressof72
ksi(500MPa)orless.
6/24/2010
EngineeringDynamics,Inc
10
StrengthofTubularJoints
MajorUpdate
Additionalguidanceondetailingpractice
API2000
6/24/2010
EngineeringDynamics,Inc
11
StrengthofTubularJoints
MajorUpdate
Additionalguidanceondetailingpractice continued
API2007
6/24/2010
EngineeringDynamics,Inc
12
StrengthofTubularJoints
MajorUpdate
Punchingshearapproachremoved
API2000
API2007
Theadequacyofthejointmaybe
determinedonthebasisof(a)
punchingshearor(b)nominalloads
inthebrace.
Thejointinteractionratio,IR,foraxial
loadsand/orbendingmomentsin
thebraceshouldbecalculated
usingthefollowingexpression,
6/24/2010
EngineeringDynamics,Inc
13
StrengthofTubularJoints
MajorUpdate
NewStrengthfactorQu formulations
API2000
API2007
6/24/2010
EngineeringDynamics,Inc
14
StrengthofTubularJoints
MajorUpdate
NewchordloadfactorQf formulations
API2000
6/24/2010
API2007
EngineeringDynamics,Inc
15
StrengthofTubularJoints
MajorUpdate
StrengthforaxiallyloadedYandXjointswithshortcanlengthsreduced
API2000
API2007
N/A
Forsimple,axiallyloadedYandXjointswherea
thickenedjointcanisspecified,thejoint
allowablecapacitymaybecalculatedas
follows,
6/24/2010
EngineeringDynamics,Inc
16
StrengthofTubularJoints
MajorUpdate
ImplementationintoSACSjointcanprogram
API2000
API2007
Fullyimplemented
Fullyimplemented
6/24/2010
EngineeringDynamics,Inc
17
StrengthofTubularJoints
Example
SimpleTjoint:
Brace34:16x0.375 5.0ft
Chord13&32:24x0.375 8.25ft
Can:24x0.625 1.75ft
AllFy =36ksi
Loadatbracejoint4:
Fx=10.0kip
Fy=7.5kip
Fz=50.0kip
Loadatconnectingjoint3:
Fx=400.0kip
Fy=50.0kip
MemberLengthshowninft
6/24/2010
EngineeringDynamics,Inc
18
StrengthofTubularJoints
ExampleResultsCompared
API2000 Punchingshearjointcheckwithfinalunitycheckratio=0.974
* * J O I N T
C A N
D E T A I L
(JOINT ORDER)
COMMON CHORD BRACE ****** CHORD ***** JOINT GAP *** BRACE **
JOINT JOINT JOINT O.D.
WT
FY TYPE
O.D.
WT
(IN) (IN) (KSI)
(IN) (IN) (IN)
3
24.00 0.625
36.0
16.00 0.375
R E P O R T * *
CHORD
*
ACTING STRESSES
* ***
PUNCHING SHEAR
BRACE LOAD *CHORD**
BRACE
*
ALLOWABLE STRESSES
ANGLE CASE SRSS
FA
OPB
IPB
FA
OPB
IPB
(DEG)
(KSI) (KSI) (KSI) (KSI) (KSI) (KSI) (KSI)
***
UNITY
CHECK
90.00
0.974
11.51
-1.63
3.84
5.12
3.66
6.65
11.15
API2007 Braceloadsinteractioncheckwithfinalunitycheckratio=1.168
* * J O I N T
EFFT.
COMM CHRD BRCE ****** CHORD **** CHORD JNT
JNT JNT JNT O.D.
WT
FY LNGTH TYP
IN
IN
KSI
FT
3
24.00 0.625
36.0
3.5
GAP
IN
C A N
D E T A I L
(UNITY CHECK ORDER)
CHORD
*** BRACE **
O.D.
WT
IN
IN
16.00 0.375
R E P O R T * *
*
ACTING STRESSES
BRACE LOAD *CHORD**
BRACE
ANGLE CASE STRESS
FA
OPB
DEG
KSI
KSI
KSI
* ***
PUNCHING SHEAR
*
ALLOWABLE STRESSES
IPB
FA
OPB
IPB
KSI
KSI
KSI
KSI
***
UNITY
CHECK
90.00
8.54
1.168
1 -11.51
-2.72
6.40
7.20
10.16
21.30
JointCanLength
6/24/2010
EngineeringDynamics,Inc
19